0% found this document useful (0 votes)
62 views1 page

5.5.2.1 - Label - Convention - 13 - 05 - 2011

The document discusses labeling requirements for various telecommunications equipment including coaxial cable, Ethernet cable, fiber optic cable and more. Specific labels are mentioned for outdoor equipment as well as indoor equipment and components like power fuses.

Uploaded by

Petyo Georgiev
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views1 page

5.5.2.1 - Label - Convention - 13 - 05 - 2011

The document discusses labeling requirements for various telecommunications equipment including coaxial cable, Ethernet cable, fiber optic cable and more. Specific labels are mentioned for outdoor equipment as well as indoor equipment and components like power fuses.

Uploaded by

Petyo Georgiev
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PD2528 M 1 E1-P3-P1

UV resistant tie rap + letters 2 pcs plastic tie rap with label (flag) Printed authoadesive label
Coaxial\Eth\FO at ODU level Coax/Eth/FO indoors Power fuse of MXC/MSS
Printed authoadesive label

Board name NCC/NPC/MSSA or B


Position on pannel (ODU 300 only)
RF Panels and DDF pannels

Name of MXC/MPR NE in NOC


P A N E L 0 1
2
3
4

Possible values
Equipment ID on site
Channel polarization
ODU Main/Standby

ODU Main/Standby
5

Pannel ID on rack
Distant Site Code
Antenna Azimuth
Logical Channel

Logical Channel
6
Distant Site ID

7
8

separator

separator
9

Ex P D 8 1 6 2S 1V 1 6 5 Ex P D 2 5 2 8M 1 E 1 - P 3 - P 1 Ex M W A 1M S S A
P D 1 1 1 1M 2V 1 1 1 M T 1 1 1 1M 2 1 1 1 Printed authoadesive label M W A 1N C C
B S 2 2 2 2S 3H 2 2 2 B S 2 2 2 2S 3 2 2 2 IP for INU/MSS on right top case 2M P S A
S F 3 3 3 3 4 3 3 3 S F 3 3 3 3 4 3 3 3 Ex 1 0. 2 3 7. 4 1. 1 3 S B
O 4 4 4 4 5 4 4 O 4 4 4 4 5 4 4 4 Ex mask: 255.255.255.192 4
Possible values
Possible values

possible values
N 5 5 5 5 6 5 5 N 5 5 5 5 6 5 5 5 5
A 6 6 6 6 7 6 6 A 6 6 6 6 7 6 6 6 Printed auto adhesive label 6
7 7 7 7 8 7 7 7 7 7 7 8 7 7 7 direction name, polarization and logical
7
8 8 8 8 9 8 8 8 8 8 8 9 8 8 8 channel number on INU/MSS on top case at 8
9 9 9 9 10 9 9 9 9 9 9 10 9 9 9 RAC or MPT ACC position. 9
Ex S T A RO V O V 1
Ex S T A RO V O H 2

E1-PD1-01 PD8160 M 2 E1-P4-S3-1 MWA-1-MSS-A


H-E2-S2

1 plastic tie rap with label 2 Plastic tie rap with label 1 plastic tyrap with label 1 plastic tie rap with label
NCC/NPC power cable Coaxial indoor at patch pannel E1/DS1 cable 48V power cable to INU/MSS

RAC or MPT acc. slot ID (xconnect)

Trib port on DAC16E1 or PDH acc.

Board name NCC/NPC/MSSA or B


Fuse number on power distributor
Pannel Distributor ID on rack/site

Name for MXC/MPR NE in NOC


RAC or MPT acc. slot ID

DAC or PDH acc. slot ID

Equipment ID on rack
Equipment ID on site

Equipment ID on site

Equipment ID on site
Channel polarization
ODU Main/Standby
Distantant site ID

Logical Channel

Separator

Separator

Separator
Separator

Separator

Separator

Separator
separator

separator

Ex E 1 - P D 1 - 0 1 Ex P D 8 1 6 0M 2 V - E 1 - S 1 Ex E 1 - P 1 - S 1 - 1 Ex M W A - 1- M S S A
E 1- P D 1- 0 0 P D 1 1 1 1M 1 V - E 1- S 1 E 1 - P 1 - S 1 - 1 M W A - 1- N C C
2 2 1 1 B S 2 2 2 2S 2 H 2 2 2 2 2 2 2 M P S A
3 3 2 2 S F 3 3 3 3 3 3 3 3 3 3 3 S B
4 4 3 O 4 4 4 4 4 4 4 4 4 4 4
possible values

5 5 4 N 5 5 5 5 5 5 5 5 5 5 5
possible values

possible values

possible values
6 6 5 A 6 6 6 6 6 6 6 6 6 6 6
7 7 6 7 7 7 7 7 7 7 7 7 7
8 8 7 8 8 8 8 8 8 8 8 8 8
9 9 8 9 9 9 9 9 9 9 9 9 9
9 10