0% found this document useful (0 votes)
60 views

Software Controller

The document describes the software interface for the SMARTSENSYS WISE CONTROLLER, including its main menu, sensor network display, sensor list, status indicators, sensor information, and options for viewing sensor data, alerts, charts, and calibration.

Uploaded by

Anthony Fu
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views

Software Controller

The document describes the software interface for the SMARTSENSYS WISE CONTROLLER, including its main menu, sensor network display, sensor list, status indicators, sensor information, and options for viewing sensor data, alerts, charts, and calibration.

Uploaded by

Anthony Fu
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

SMARTSENSYS

For Infrastructure Maintenance and Safety

SMARTSENSYS WISE CONTROLLER CON900

THE SOFTWARE INTERFACE

1. Menu System

2. Sensor Network At a Glance


4. Sensor Status Indicators

3. Sensor List

1. Menu System
File: View logs; Clear Data; Exit SMARTSENSYS WISE Controller
Configuration: Enter Key; Add Sensor; Add Gateway; Configure
External Notifications
About: Version; Local IP Addresses; Help

2. Sensor Network At a Glance


Displays the most current readings for every sensor in the selected
network, all on one easy-to-read page.

3. Sensor List
Displays all sensors that are currently assigned to your sensor network.
Clicking on the sensor names allows you to view information for that

3210 Countrybend Ln Champaign, IL 61822 USA


Phone 312-612-0688 Cell 217-778-2718
[email protected] www.smartsensys.com
SMARTSENSYS
For Infrastructure Maintenance and Safety

specific sensor. Clicking the edit button by a sensors name allows


you to change the sensor specific settings such as sensor name and
heartbeat (report interval).
Noted: All information stored on the sensor will be downloaded to the
sensor on the next sensor heartbeat (Check-in). If you make a change
to any setting, you will need to wait until the sensor has downloaded the
new information before you can edit the configuration settings again.

4. Sensor Status Indicators


Displays the status for each individual sensor.
Sensor is checking in and within user defined safe parameters.
Sensor has met or exceeded a user defined threshold or triggered
event.
Sensor has not checked in.

5. Current Sensor Information


Display the most current information of the selected sensor, including:
last check-in, signal strength, battery power and last sensor reading.

6. Sensor Data Window


Select a tab to change between:
o History: Displays a history of the selected sensors data
o Alerts: Allows you to view, add, edit or delete notifications for
each sensor
o Chart: Displays a graphical view of the selected sensors data
o Export: Allows you to archive data by exporting as a.csv
o Calibrate: Allows you to calibrate certain sensors for greater
accuracy.
The tab highlighted is your current selection.

3210 Countrybend Ln Champaign, IL 61822 USA


Phone 312-612-0688 Cell 217-778-2718
[email protected] www.smartsensys.com
SMARTSENSYS
For Infrastructure Maintenance and Safety

CONFIGURING SENSORS

Click the Edit icon next to the name of the sensor that you would like to configure.

The sensor configuration window allows you to set the primary configurations for each
sensor. Within this window you can change the name of the sensor, set the heartbeat (how
often the senor check-in with the software default is every 10 minutes), and change the
unit of measurement. When you have finished making changes, press the Save button at
the bottom of this section.

Note: Be sure to click the Save button anytime you make a change to any of the sensor
parameters. All changes made to the sensor settings will be downloaded to the sensor on
the next sensor heartbeat (check-in). Once a change has been made and Saved, you
will not be able to edit that sensors configurations again until the sensor has downloaded
the new setting.

SENSOR HISTORY

Clicking on the History tab within the sensor data window will allow you to
view all of the stored data for the selected sensor. The sensor data shows
date, time signal strength, battery level and the sensor reading.

3210 Countrybend Ln Champaign, IL 61822 USA


Phone 312-612-0688 Cell 217-778-2718
[email protected] www.smartsensys.com
SMARTSENSYS
For Infrastructure Maintenance and Safety

SETTING UP ALERTS

Clicking on the Alerts tab within the sensor data window will allow you to do
the following: view existing notifications, create new notifications, edit a
notification or delete a notification. Alerts will appear on-screen and in an
email if external alerts are set.

To create a new notification, click on the Add Alert button at the right side
of the window and enter the desired alert parameters. To edit or delete an
existing alerts, click on the Edit icon or the Delete icon .

Alert Text
This is a user defined message that will be emailed or texted to the recipient when the
conditions have been met and the notification is sent. Please limit your message to 50
characters (including spaces).

Notify When Sensor


This area allows you to set the conditions that must be met to trigger a notification from the
system. The conditions are dependent upon what type of sensor is being used.

Dont Notify Again For


Allows you to define how frequently you want to be notified if the sensor condition is still
met or exceeded. For example, if the temperature is still above 80 you can be notified
every 10 minutes until you have addressed the issue.

Is Active
Allows you to turn off a notification temporarily, without deleting it.

3210 Countrybend Ln Champaign, IL 61822 USA


Phone 312-612-0688 Cell 217-778-2718
[email protected] www.smartsensys.com
SMARTSENSYS
For Infrastructure Maintenance and Safety

Configuring Email Settings


Email alerts can be sent from the software if the external notifications are configured and
the computer running the software has an active internet connection. To setup email alerts,
click on File in the menu system and select Configure External Notifications. Complete
all the information here and click Save. You will need to know the SMTP settings for the
email address to send from (similar to setting up an account in any email program). Any
alerts set in the software will now be sent via email as well as viewed on-screen.

Sensor Charts
Clicking on the Chart tab within the sensor data window will allow you to view the sensor
data ina graphical format. To change the date range of the displayed information, type in
the Start Date and End Date boxes then click the Refresh button.

3210 Countrybend Ln Champaign, IL 61822 USA


Phone 312-612-0688 Cell 217-778-2718
[email protected] www.smartsensys.com
SMARTSENSYS
For Infrastructure Maintenance and Safety

Exporting Data
Clicking on the Export tab within the sensor data window allows you to export the current
sensors data to a comma separated value (.csv) file as well as export the data for all
sensors in the network.

When you click either of the export buttons, a pop-up window will appear asking you
where you would like to save the data file. Select a location then click Save. The data will
be exported to a comma separated value (.csv) file for use in spreadsheet software such
as Microsoft Excel.

Calibrating Sensors
Certain sensor types allow for calibration, providing you with more accurate data readings
in the environment the sensors are being used in. When you click on the Calibrate tab
you will be given the sensors last recorded reading, enter the correct information in the
box and the software will apply the calibration to all future sensor readings.

For additional information or more detailed instructions on how to use SMARTSENSYS


WISE CONTROLLER, please visit our website http://www.smartsensys.com/support/.

All trademarks are property of SMARTSENSYS 2013 SMARTSENSYS LLC All Rights Reserved.

3210 Countrybend Ln Champaign, IL 61822 USA


Phone 312-612-0688 Cell 217-778-2718
[email protected] www.smartsensys.com

You might also like