DDCTool 4x Users Manual e B
DDCTool 4x Users Manual e B
x
DCF 500/700
DCS 500
DCV 700
TSU
User's Manual
User's Manual
DDCTool 4.x
ACV 700
DCF 500/700
DCS 500
DCV 700
TSU
Chapter 6 - ActValues......................................................................................................................................6-1
Graph Display (Single DDC)....................................................................................................................6-1
Automatic Scaling..........................................................................................................................6-3
Stop/Restart Graph Display.....................................................................................................................6-4
Define Value 1 ... 4 ..................................................................................................................................6-4
Define Object ...........................................................................................................................................6-4
Set Object Value......................................................................................................................................6-4
Undo Object Value...................................................................................................................................6-4
Show Descriptions ...................................................................................................................................6-4
Define Step A and Step B........................................................................................................................6-5
Start Value Recorder ...............................................................................................................................6-7
Stop Recorder..........................................................................................................................................6-8
Chapter 8 - Diagrams.......................................................................................................................................8-1
DDCTool 4.x I
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 1 - Table of Contents
Diagrams..................................................................................................................................................8-1
Diagram Window .....................................................................................................................................8-2
Chapter 11 - Faults.........................................................................................................................................11-1
Reading the Last DDC Fault/alarm Code ..............................................................................................11-1
Uploading/clearing the Fault Logger......................................................................................................11-2
Chapter 12 - Other..........................................................................................................................................12-1
Restart Communication with the DDC...................................................................................................12-1
Read the DDC Communication Statistics..............................................................................................12-1
Clear Graph Area...................................................................................................................................12-1
Set Y-axis Zero to... ...............................................................................................................................12-1
Copy Curr Graph to Ref.........................................................................................................................12-2
Show/Hide Ref Graph............................................................................................................................12-2
Ref Graph Shift ......................................................................................................................................12-2
Window Calculator.................................................................................................................................12-3
Set DDC Time........................................................................................................................................12-3
Lock Value Changes..............................................................................................................................12-4
I/O Test (ACV 700 only).........................................................................................................................12-5
Chapter 13 - Exit.............................................................................................................................................13-1
Exit .........................................................................................................................................................13-1
DDCTool 4.x ii
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 2 - Introduction
The DDCTool program can be used with the following DDC types:
ACV 700
DCV 700
DCS 500
TSU
About this Manual Chapter 3 - Installation of the DDCTool 4.x describes the installation
of the DDCTool hardware and software in single DDC configurations.
Chapter 5 - File describes how you can save and open graph and
configuration information.
Chapter 9 - DataLogger describes how you can define the data logger
channels and other data logger control parameters and how you can
upload, display and save the collected data logger samples.
Chapter 10 - Control describes how you can control the DDC in local
control mode.
Chapter 11 - Faults describes how you can upload, display and save
the content of the fault logger.
Starting the The program is started by double clicking the DDCTool 4.0 shortcut.
DDCTool If the DDC connection is not working properly then a "Cannot start
drive communication" error box will appear on the screen (see
Chapter Installation of the DDCTool / Troubleshooting).
If error message "PC OVERLOAD" appears on the screen (or
DDCTool fails during parameter upload) then you must increase the
value of the startup parameter M (see Appendix 1).
NOTE: If your PC includes a Power Management feature then turn it
off and restart the program without changing the M parameter.
Screen Layout of
the DDCTool
The actual values to be monitored in real time (in the numeric form)
are displayed in the upper part of the screen.
In the middle of the screen there is a graphical display area with scale
lines.
On the STATE line above the graphical display area, the following
DDC status information is displayed:
Status Panel
ACV 700 If you define Value4 = signal 101-04 (MAIN_STATUS_WORD) then
the status information of this ACV 700 signal is shown on the right
side of the screen (gray text = inactive state):
Figure 4 - 2. ACV 700 status panel on the right side of the screen.
Figure 4 - 3. ACV 700 status panel on the right side of the screen.
Numeric The actual values to be monitored in real time are selected with the
Object push button and with the Value1, Value2, Value3 and Value4
Monitoring of push buttons. The push buttons have the following differences:
Actual Values
The value as such is the actual The value can also be the
value. difference between two actual
values (or between an actual
value and a constant value).
The Object push button is generally used only for selecting objects
whose contents are to be changed. The Value push buttons are used
to select actual values that are to be monitored numerically and/or
graphically.
Object Push After the Object push button has been clicked, a dialog box is
Button displayed on the screen.
From the list one of the following actual values can be selected for
monitoring:
a parameter or signal. With the List push button you can select
the desired parameter or signal from the parameter/signal list
(either with a double click of the mouse or by pressing the space
bar).
When the selection has been made, click the OK push button. The
name of selected parameter/signal will be displayed at the right side
of the Object push button and at the right side of the ObjVal push
button there will appear the actual value of the selected object
(selection of the actual value's display format is explained below in
Chapter Changing Values).
Object Selection By clicking on the object name (at the right side of the Object push
List button) the Object Selection List window can be displayed.
If you click on a list item (parameter/signal) then this item will be the
new object.
If you double click on a list item then this item will be the new object
and the value change dialog box is automatically displayed for value
change (see below Chapter Changing Values).
By means of the Add push button you add new items to the end of
the item list.
You can select one or more parameters/signals from the dialog box
that appears when you click the Add button. Click the OK push
button of the dialog box when you have selected the item(s) you want
(if you want to clear the item list of the object selection list window
before addition then click the OK (with clear) push button).
By means of the Del push button you delete the selected item from
the list.
By means of the Save push button you save the object list to a disk
file (name extension must be .QDO).
By means of the Open push button you read a previosly saved object
list from a disk file.
You can move back from the selection list window to the main
window, and the selection list window will remain visible on the
screen. By means of the Done push button you remove the selection
list window.
Value Push After you have clicked a Value push button, a dialog box will be
displayed on the screen.
Buttons
When the above mentioned selections have been made, click the OK
push button. Next to the Value push button clicked there will appear
the actual value, in the selected format or the difference between the
value to be monitored and the reference value.
Changing Values The parameter (or signal) to be changed is first selected with the
Object push button (or with the Object Selection List).
Next click the ObjVal push button, which brings up on the screen a
dialog box with a selection list for the display format and a data entry
field for entering the new value.
If you wish to change the display format, select a new format from the
list of formats (a signed integer, an unsigned integer, a hexadecimal
number or a binary number).
If you wish to change the value, write the new value in the data entry
field.
Finally, click the OK push button (or press the Enter key).
NOTE: If you wish to change only the display format, leave the data
entry field blank!
DDCTool 4.x 4 - 10
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 4 - Using the DDCTool
If you have selected the Redisp check box then DDCTool redisplays
the dialog box so that you can change the value of the same object
again. Click the Cancel push button (or press the Esc key) when you
want remove the dialog box from the screen.
You can restore the previous value back if you press the F12 function
key (or click the Undo push button of the dialog box if the box is
visible) as the first operation after value change.
DDCTool 4.x 4 - 11
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 4 - Using the DDCTool
DDCTool 4.x 4 - 12
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 5 - File
Open By means of the command Open Configuration in the File menu you
can restore previously saved measurement configuration definitions.
Configuration
Open Graph By means of Open Graph in the File menu you can restore any
previously saved graph file. When you have selected the file you want
to restore then a dialog box will be displayed on the screen.
With this dialog box you can restore the graph source and/or scaling
definitions and/or the graph curves. Graph curves can be copied to
normal curves or reference curves. You can make a copy to
reference curves only if the current X- and Y-axis values are the
same as they were when the graph curves to be copied were saved
(use of reference curves, see Chapter Other / Show/Hide Ref Graph).
Save Configuration When you select this command all measurement configuration
definitions of the DDCTool (Object push button, Value push buttons,
Step push buttons etc.) are saved for later use to the file
CONFIG.QDC in the DDCTOOL directory. If the file CONFIG.QDC
already exists then its old content is overwritten.
Save Configuration When you select this command a dialog box will be displayed on the
screen. By this box you define a file (extension must be .QDC) and all
As measurement configuration definitions (Object push button, Value
push buttons, Step push buttons etc.) are saved to this file for later
use.
Save Graph As You can save the current graphical display information to a disk file
for later use. When you select this command a dialog box will be
displayed on the screen.
With this dialog box you select the graph bitmap file mode, graph line
width type and the desired file directory, write the base part of the file
name (e.g. MEAS23) and write the Comment line (e.g. customer
name, application etc.).
When you click the OK push button two or three disk files will be
created:
text (.TXT) file: When you are creating a document (e.g. with the
WinWord program) you can insert the content of this file into the
document.
bitmap (.BMP) file: When you are creating a document (e.g. with
the WinWord program) you can insert the content of this file into
the document.
Save PrintScreen If you wish to save the whole current screen with its graphics curves
for later use, first press the PrintScreen key on your keyboard. This
Image As will copy the entire content of the window to the clipboard. In error
situations Save PrintScreen Image As is an easy way to save error
messages in case they are needed later.
Next select the command Save PrintScreen Image As from the File
menu. The Clipboard window will be displayed on the screen. Select
the command Save As from this window's File menu and execute the
save to the desired disk file in the directory you want to use. Finally,
close the Clipboard window by selecting File-Exit.
When you wish to use a saved image at a later time, for example, in a
document that is created with the WinWord program, you must first
read the image file back to the clipboard with the Clipboard program
that is started, say, from the Program Manager's Clipboard icon and
then move the picture to WinWord or first edit it e.g. in Paintbrush.
When an image is read to the clipboard, you can use the Paintbrush
program to remove from it, say, the part above the graph display
area. This should be done before pasting the image into a document
that is being created. Follow the steps below:
if the Paintbrush is not running, start it, enlarge its window to the
maximum size and remove the Tools and Palette help windows
from the main window by means of the View menu. If the
Paintbrush has already been started earlier, select File-New.
copy the image that has been read to the Paintbrush window by
selecting View-Zoom Out, Edit-Paste (twice!) and View-Zoom
In.
clip the desired image area with the mouse (press the mouse's
left-hand button down at some corner of the desired image area
and with the button still held down, drag the clipped area to the
desired size. Then release the mouse button)
finally, copy the clipped area to the clipboard (in place of the
before read image) by selecting Edit-Copy
Print Graph If you have a printer connected to your PC then the current graphical
display can be printed with source and scaling definitions by means of
the command Print Graph in the File menu.
About DDCTool An About DDCTool box will appear. The DDCTool version and the
DDC type are shown there.
Graph Display The width of the display area is 500 pixels and it is divided into 10
parts by broken lines. If the updating interval of the actual values to
(Single DDC) be monitored is e.g. 3 ms (the fastest possible), then the width of the
entire area corresponds to a time of 1.5 seconds (500 * 3 ms).
Next you select the Graph Display (Single DDC) command from the
ActValues menu. The actual values to be monitored graphically are
selected from the curve list to be displayed on the screen.
A curve can display either an analog value or a bit value. If you want
to display an analog value then you can define the scalings and
offsets to be used in the display (the computational formula is
presented above the list).
If you want to display a bit value then you must define the bit to be
displayed as follows:
value_number(1...5):bit_number(0...15)
Finally, you can define the display interval as a multiple of the DDC
communication rate (see Appendix 1, parameter M). The Graph
Sample Interval thus expresses whether each actual value
transmitted by the DDC is to be displayed (in which case the curve
has maximum precision but covers a short time span) or whether the
actual values transmitted by the DDC are to be sampled only at
certain intervals (in which case the curve is less precise but covers a
longer time span).
When you have done all the definitions you click the OK push button
to start the real-time graphical display (at the left side of the push
buttons, corresponding to the analog values selected, there will be a
# sign). During display, the display interval, the scaling and the
number of curves to be displayed can be changed by means of the
command Graph Display (Single DDC) in the ActValues menu.
You can copy the current graph curves to the reference curve
memory by means of the command Copy Curr Graph to Ref in the
Other menu (see Chapter Other / Copy Curr Graph to Ref).
Automatic If you click the OK (autoscal) push button then all selected analog
Scaling graphs are autoscaled.
Stop/Restart Graph The display can be stopped by using the F4 function key (or by
selecting the command Stop/Restart Graph Display in the
Display ActValues menu).
Define Value 1 ... 4 See Chapter Using the DDCTool / Value Push Buttons.
Define Object See Chapter Using the DDCTool / Object Push Button.
Set Object Value See Chapter Using the DDCTool / Changing Values.
Undo Object Value See Chapter Using the DDCTool / Changing Values.
Show Descriptions The current definitions of the Value and Object push buttons can be
displayed on the screen by using the F9 function key (or by selecting
the command Show Descriptions in the ActValues menu).
If the text "Description not found" is shown it means that you have
never selected this DDC as a target DDC after the startup of
DDCTool.
Define Step A and For the purpose of measuring step responses, you can define two
step push buttons (Step A and Step B) by means of the commands
Step B Define Step A and Define Step B in the ActValues menu.
The step push buttons are visible only after the definition has been
made. The Step A push button is generally used for making the
actual step (positive or negative), whereas the Step B push button is
used to restore the changed value back to its initial state so that a
new step can be made.
Before making a step, you must start the graphical monitoring of the
desired actual values. If you check the box Restart Graph Display in
the Define Step B dialog box then the monitoring starts automatically
every time when you click the Step B push button.
When a step has been made, the graphical display can be stopped
manually by means of the F4 function key. If you set the value of the
optional Sample Count After Step field in the Define Step A dialog
box then the graphical display stops automatically at the desired point
(in this case you must define Value1 so that the value to be
monitored is the same as the step signal and the reference value is
zero).
If you check the box Show Ref Graph After Step Stop in the Define
Step A dialog box then the reference curves (if you have defined
them) are automatically shown on the screen after the graphical
display has stopped (you cannot use this check box if the Sample
Count After Step field is empty).
You can remove a previously defined Step button from the screen by
clearing the Step Signal field in the step definition dialog box of the
Step button before clicking the OK button of the dialog box.
Start Value The actual values to be recorded are first defined by means of the
Value1, Value2, Value3 and Value4 push buttons.
Recorder
Next you select the Start Value Recorder command from the
ActValues menu.
This brings up on the screen a dialog box by means of which you can
carry out the following definitions:
If the record interval time is not long enough during the recording then
an error message SAMPLE INTERVAL (n/m ms) TOO SHORT is
displayed on the STATE line (if this happens too often then the
recording is automatically stopped). If this error message is displayed
seldomly then the reason may be an error in the communication
between the PC and the DDC.
With one DDC and the value of the startup parameter M is 1 (see
Appendix 1) the actual values of Value1...4 are displayed at the right
sides of the Value buttons during the record.
Stop Recorder The recording can be stopped by pressing the F8 function key (or by
selecting the Stop Recorder command from the ActValues menu).
The parameter list of the dialog box has the following columns:
You can select a parameter from the parameter list by means of the
Up and Down arrow keys and/or the mouse. By means of the New
value data entry field and the OK push button (or the Enter key) you
can change the value of the selected parameter (an asterisk will be
displayed after changed parameters). This change is immediately
transmitted to the DDC. You can restore the previous value back if
you click the Undo push button (or press the F12 function key) as the
first operation after value change.
write the new value of the selected parameter and press the
Enter key. Now the value of the selected parameter changes
and the selection moves automatically to the next parameter.
By means of the File Open push button you can read a parameter file
that has previously been saved (see below) and display the
parameters in the parameter list of the dialog box.
By means of the Upload push button you can upload all the DDC
parameters and display them in the parameter list of the dialog box.
By means of the File Save push button you can save the parameter
list of the dialog box to a disk file (extension must be .QDP). On the
Comment line you can write, for example, the customer's name, the
application, etc.
By means of the Download push button you can set all the DDC
parameters to the values specified in the parameter list of the dialog
box.
By means of the Compare push button you can compare the current
parameter list of the dialog box with another parameter list (saved by
the File Save push button).
By means of the Version Update push button you can convert an old
parameter list file into a new format when the parameter version
number in the DDC firmware has changed. The procedure is as
follows:
Upload parameters (click the Upload push button) from the new
firmware or open a parameter list file (File Open) that you have
uploaded from the new firmware.
Now you can download and/or save the updated parameter list
(check the correctness of the list before you do this!)
By means of the Print push button you can print the current
parameter list (if you have a printer connected to your PC).
Processing the Use of the command Parameters (No Immediate Update) in the
Params menu brings up on the screen a dialog box by means of
Parameters (No which you can execute the same operations as in the previous
immediate update) chapter. The only difference is that now a change made in the
parameter list (by the New Value data entry field and the OK push
button) is not transmitted to the DDC.
Diagram Window By means of the Open Diagrams command in the File menu of the
Diagram window you read a diagram file.
if you press the CTRL key and click on a line that is connected
to a parameter/signal then the actual value of this
parameter/signal is shown on the screen in real time.
If you do this when the cursor is not on a parameter/signal line
(or there are no such lines at all in the diagram) then you can
define any parameter/signal you want to monitor in the click
position.
If you press the F10 function key then you can see in the
diagram the indeces of the parameters/signals you have defined
(press F10 again to restore the normal display state).
By means of the Save Diagrams As command in the File menu
of the Diagram window you can save the current diagram file
with the display definitions you have made.
Use of the Data The data logger resides in the DDC. You can control its operation and
upload its contents by the DDCTool program.
Logger
Data logger has six logging channels. The maximum number of
sample values in one channel is 1000.
With the Codes button you can select the trig condition code.
Figure 9 - 5. Control dialog box when the data logger is not logging.
Click the push button corresponding to the desired function (or the
Cancel push button if you only want to find out the data logger's
status and you do not wish to carry out any control action).
Upload When the logging has stopped, the sample values logged to the data
logger channels are uploaded from the DDC by means of the
command Upload in the DataLogger menu (if graphical monitoring of
the actual values is in progress, it must first be stopped with the F4
function key).
The time scale is displayed below the X axis in such a way that the 0
point is at the triggering point (or at the right-hand edge if no
triggering has taken place). The short horizontal broken colour lines
at the right-hand edge of the graph display show the values of
Y-offset Bs.
Automatic If you click the OK (autoscal) push button then all selected channels
Scaling are autoscaled.
You can copy the current graph curves of the uploaded data logger
sample values to the reference curve memory by means of the
command Copy Curr Graph to Ref in the Other menu (see Chapter
Other / Copy Curr Graph to Ref).
Expand Graph The sample value curves can be expanded horizontally by clicking in
the graph area at the X-point you want to expand (during the
Display expansion, the expansion point remains where it is on the screen).
With each click the curves expand to double their previous size until
they have expanded 64-fold compared with their initial size (with each
click the expansion point can be located in a different place). If a
mouse is not in use, the same function can be performed by means of
the Expand Graph Display command in the DataLogger menu.
Numeric Display of The uploaded sample values can also be displayed in numerical form
by means of the command Numeric Display of Uploaded Samples
Uploaded Samples in the DataLogger menu.
By means of the Print push button you can print the sample values (if
you have a printer connected to your PC).
By means of the FileSave push button you can save the sample
values to a disk file (extension is .TXT). The save format is the same
as in the Excel program (sample value lines are separated by
NewLine characters and sample values in a sample value line are
separated by Tab characters).
You quit the displaying of the numeric values by clicking the Done
push button.
Now you can select the number of the first sample file batch (1...99)
and the name and directory of the log file (all sample files will be
written to this directory, too).
When you click the Start push button then DDCTool continously polls
data logger statuses of connected DDC.
WARNING! If there are one DDC connected to the DDCTool then this
polling may increase processor load of this DDC too much. Load increase in
a DDC is (approx.) = 10 / 1 %.
After start the text on the Cancel push button is changed to Stop.
upload data logger samples from DDC to disk files. The name
format of a sample file is:
DLSbb250.TXT
If the disk becomes full then the sample files of the oldest file
batch are removed from the disk before the new sample files are
written.
writes log information (ID of the DDC that has been trigged,
date, time and batch number) to the log list on the screen and to
the user-specified log file.
waits untill the triggering condition is off in the DDC that has
been trigged at the beginning of this sequence (no wait if the
condition is now on but it has been in the off state for a while
after the beginning of this sequence).
Local/Remote Select the command Local/Remote Control from the Control menu.
The control window appears on the screen.
Control
You can move back from the control window to the main window, and
the control window will remain visible on the screen. If you wish to
hide the control window, click the Done push button.
Local Control
By means of the Loc/Rem push button you switch from local control
to remote control.
By means of the 1 push button you switch the main controller ON (DC
drives only).
By means of the 0 push button you switch the main controller OFF
(DC drives only).
By means of the Stop push button you bring the DDC down as it is
programmed.
DDCTool 4.x 10 - 1
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Fehler! Nur HauptdokumentChapter 10 - Control
By means of the RefVal push button you set the DDC's speed
reference value.
If an ACV 700 drive is stopped in local mode the drive does not notice
it but continues to do what it was doing.
Remote Control
DDCTool 4.x 10 - 2
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 11 - Faults
Reading the Last By means of the command Read Last Fault/Alarm Codes in the
Faults menu, you can read the fault/alarm code corresponding to the
DDC Fault/alarm last fault/alarm situation that has occurred in the DDC (if the
Code fault/alarm has already disappeared a copy of the fault/alarm code is
stored in the DDC). The read operation removes the fault/alarm
code's copy if the fault/alarm situation has already disappeared.
DDCTool 4.x 11 - 1
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 11 - Other
Uploading/clearing If the graphic monitoring of the actual values is running, it must first
be stopped with the F4 function key before you can do the upload. By
the Fault Logger means of the command Upload Fault Logger in the Faults menu,
you can read the content of the DDC's fault logger (a maximum of the
100 latest faults, alarms or events). When the entire content has been
read, above the fault list will appear the DDC's date and the clock
time at the instant of the last fault uploaded. In the Fault Logger the
date, time of the fault, the fault code and the description of it are in
the faults list; latest fault on top.
If the time of DDC has not been set (see Chapter Other / Set DDC
Time) or the APC board has not been connected to the DDC, times
and dates in the Fault Logger can be invalid.
By means of the Print push button you can print the content of the
fault logger (if you have a printer connected to your PC).
DDCTool 4.x 11 - 2
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 11 - Other
By means of the FileSave push button you can save the content of
the fault logger to a disk file.
By means of the Clear push button you can clear the content of the
fault logger.
After you wish to leave the fault logger dialog box click the Done push
button
DDCTool 4.x 11 - 3
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 11 - Other
DDCTool 4.x 11 - 4
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 12 - Other
Read the DDC By means of the command Read Comm Statistics in the Other
menu you can see the number of communication errors.
Communication
Statistics
Clear Graph Area You can, if needed, remove the stopped graphical display from the
screen with the F5 function key (or by selecting the command Clear
Graph Area in the Other menu).
Set Y-axis Zero to... The height of the graphical display area is 300 pixels, and it is divided
into six parts by broken lines. By means of the Set Y-axis Zero to...
DDCTool 4.x 12 - 1
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 12 - Other
commands in the Other menu the zero point on the Y axis can be set
to the top of the area, to the middle, or to the bottom. By scaling the
display curves can be placed inside the area in the Y direction. You
can use these commands only if the graph area is empty.
Copy Curr Graph You can copy the current (stopped) graph curves (actual values or
data logger samples) to the reference curve memory by means of the
to Ref Copy Curr Graph to Ref command in the Other menu (in addition to
this you can copy the graph curves from a saved disk file to the
reference curve memory, see Chapter File / Open Graph). Each copy
replaces the previously copied reference curves.
Show/Hide Ref You can show (or hide) the reference curves on the screen with the
F6 function key (or by means of the Show/Hide Ref Graph command
Graph in the Other menu). The display of the reference curves is impossible
if the current X- and Y-axis values are not the same as they were
when the graph curves were copied to the reference curve memory.
Ref Graph Shift If normal curves hide the reference curves, then you can temporarily
raise the reference curves higher with the F7 function key (or by
means of the Ref Graph Shift command in the Other menu).
DDCTool 4.x 12 - 2
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 12 - Other
Window Calculator The window calculator is started by means of the command Window
Calculator in the Other menu.
When you no longer need to use the calculator, click the Done push
button.
Set DDC Time The command Set DDC Time in the Other menu copies the date and
time of the PC to the date and time of the DDC.
NOTE: If an APC is connected to the DDC, it will send date and time
every two seconds to the DDC and this overrides the date and time
sent by DDCTool.
DDCTool 4.x 12 - 3
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 12 - Other
Lock Value By means of the command Lock Value Changes in the Other menu
you can prevent all changes of DDC values by the DDCTool program.
Changes
If you want to lock/unlock then click the OK push button (or press the
Enter key).
DDCTool 4.x 12 - 4
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 12 - Other
I/O Test (ACV 700 Use of the command I/O Test in the Other menu brings up on the
screen a dialog box where the values of the analog and digital inputs
only) and outputs of the DDC are displayed (if the graphic monitoring of the
actual values is running, it must first be stopped with the F4 function
key).
By means of the Normal/Test push button you can start the test
mode. In this mode you can change state of the analog and digital
outputs by the controls in the dialog box. By clicking the Normal/Test
button again you return to the normal mode.
By means of the Scaling push button you can set the maximum and
minimum values used in the scaling of the analog channels.
DDCTool 4.x 12 - 5
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 13 - Exit
Exit The Exit command in the Exit menu is used to stop the program. If
desired, the current configuration settings of the DDCTool can be
copied into a CONFIG.QDC file in the DDCTOOL directory.
Figure 13 - 2. You can save the current configuration when you exit.
You can stop and restart the DDCTool program (and PC) without
stopping the DDC when the DDC is running in the remote control
mode.
If an ACV 700 drive is stopped in local mode the drive does not notice
it but continues to do what it was doing.
DDCTool 4.x 13 - 1
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 13 - Other
Figure 13 - 3. If you exit the DDCTool while in the local mode the
DDC has no control.
DDCTool 4.x 13 - 2
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 14 - Appendix 1
Startup Parameters By startup parameters you can customize your copy of the DDCTool
program. Startup parameters are used in the Target line of Properties
of DDCTool 4.x shortcut.
DDCTool 4.x 14 - 1
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 14 - Other
Example: /M2
Examples:
DDCTool 4.x 14 - 2
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 14 - Other
The default is 0.
Example: /F1
DDCTool 4.x 14 - 3
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 15 - Appendix 2
Error Messages If you make a mistake when you use the DDCTool then the program
displays an error message box. These error messages are self-
explanatory.
On the STATE line of the main window there can be one of the
following error messages:
PC OVERLOAD (text).
Your PC is so slow (or some other simultaneously running
program causes a high processor load) that it cannot receive all
the messages the DDC is transmitting.
NOTE: If your PC includes a Power Management feature then
turn it off and restart the program.
If graphical monitoring or file recording of actual values was
running then you must increase the sample interval (this error
stops the monitoring).
Otherwise, you must stop the DDCTool program and increase the
value of startup parameter M before restarting the program (see
Appendix 1).
DDCTool 4.x 15 - 1
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 15 - Other
DDCTool 4.x 15 - 2
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Chapter 16 - Appendix 3
DDCTool 4.x 16 - 1
3ADW000142R0201_DDCTool_4x_users_manual_e_b
Ident. No.: 3ADW 000 142 R0201 Rev B
Postfach 1180
68619 Lampertheim GERMANY
Tel: +49 (0) 62 06-5 03-0
Fax: +49 (0) 62 06-5 03-6 09
www.abb.com/dc *142R0201A3390000*
*142R0201A3390000*