Aeration Tank and Clarifier Design
Aeration Tank and Clarifier Design
Flow 175
BOD 250
MLSS 4000
TSS 300
F/M ratio 0.1
Volume((Flow X BOD)/(MLSS X F/M)) 109.38
SWD 4.5
Area 24.31
Length 7.0
Width 3.5
Free Board 0.5
HRT 15
Flow 175
Capacity (based on 100% recirculation required during startup) 7.3
Head 10
m3/day
mg/lt
mg/lt (Accoring to sewage manual it may vary from 30005000)
mg/lt
(Accoring to sewage manual it may vary from0.10.18.)
m3
m
m2
m
m
m
hrs(As per Sewage manual HRT 1224 hr, Hence OK)
175 m3/day
1.5
250 mg/l
250 mg/l
65.63 kg/day(AOR)
m
m
m
m
%
%
Nm3/day
hr
Nm3/hr/basin
Nm3/hr
Nm3/hr
No.
No.
No.
N m3/hr
nos
nos
m3/day
mg/l
m3
mg/l
m3/day
m3/m2.day(Ranges 816, Refer page 687, Table 87, Matcalf Eddy)
m2
m
m
m
m
kg/day
kg/m2.day <120 Hence OK(Refer page 687, Table 87, Matcalf Eddy)
hrs
m3/m.day<185 Hence OK(Refer Sewage Manual)
m(15% to 20% of clarifier dia)
m3/day
m3/hr
m
Metcalf Eddy page 429