0% found this document useful (0 votes)
364 views6 pages

API Motor Data Sheet Temp Let

This document appears to be an API 541 4th Edition data sheet for an induction machine. It requests technical specifications and site information in over 40 data fields covering the machine's basic data, site conditions, electrical system, mounting, cooling system, and starting requirements. The level of detail requested indicates this is a form to be filled out by the manufacturer and/or purchaser to define the machine design parameters and installation conditions.

Uploaded by

khalid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
364 views6 pages

API Motor Data Sheet Temp Let

This document appears to be an API 541 4th Edition data sheet for an induction machine. It requests technical specifications and site information in over 40 data fields covering the machine's basic data, site conditions, electrical system, mounting, cooling system, and starting requirements. The level of detail requested indicates this is a form to be filled out by the manufacturer and/or purchaser to define the machine design parameters and installation conditions.

Uploaded by

khalid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

JOB NO. ITEM / TAG NO.

INDUCTION MACHINE PURCHASE ORDER NO.


R API 541 4TH Edition -- DATA SHEETS REQ / SPEC NO.
E U.S. CUSTOMARY UNITS REVISION NO. DATE BY
V PAGE 1 OF 6

1 FOR / USER DRIVEN EQUIPMENT


2 SITE LOCATION QUANTITY
3 SUPPLIER SUPPLIER PROJECT NO.

GENERAL
4 Applicable To: Proposal Purchase As built

DATA SHEET INDICATES INFO. TO BE BY MANUFACTURER BY MANUFACTURER BY MANUFACTURER OR


5 NOTE:
STATUS COMPLETED BY PURCH. WITH PROPOSAL AFTER ORDER PURCHASER AS APPLICABLE
6 Basic Data:

7 Applicable Standards(1.3): NORTH AMERICAN(i.e. ANSI, NEMA) International (i.e. IEC, ISO)

8 Nameplate Power (2.2.1.1) 800 HP 3600 RPM (Synchronous)

9 6600 Volts (2.2.1.2) 3 Phase 60 Hertz

10 Motor Power Source: SINE WAVE POWER ASD power(Purchaser must confirm details, see page 2 line 14)

11 Insulation (2.3.1): CLASS F Other Temperature Rise (2.3.1) CLASS B Other

12 Other:

13 Minimum % Overspeed (2.4.5.2.7): PER NEMA MG-1 OR IEC 60034-1 Other

14 Site Data (2.1.2)


o o
15 Ambient Temperature Max Max F Min F

16 Site Elevation: feet Relative Humidity: Max % Min %

17 Motor Location Indoor Outdoor Outdoor with roof

18 Dust (2.4.1.2.2,c) Chemicals(2.1.2) Corrosive Agents (2.4.10.1.2)


o
19 Class Group Division Autoignition Temp F
Area Classification (2.1.7): Nonclassified Classified as:
20 Class Group Zone Temperature Code

21 Maximum Sound Pressure Level (2.1.3): Other

22 Seismic Loading (2.4.2.2): Nonmassive Foundation (2.4.6.1.2), Description

23 Other:

24 Enclosure (2.4.1.2):

25 Drip Proof Guarded Weather Protected Type I (WPI) Weather Protected Type II (WPII)

26 Air Filters (3.5) Provision Only Required (3.5.4) Other

27 Manufacturer Type Model

28 TEFC TEPV

29 TEAAC Tube Materials (2.4.10.8,a): Copper Alloy Stainless Steel

30 TEWAC Redundant Coolers (2.4.1.2.4,b): Yes Exchanger Location/Orientation

31 Cooling Water Conditions per 2.4.1.2.4.a: Yes No (Other)

32 Water Flow GPM

33 Tube Construction (2.4.1.4,d) Double Tube

34 Flow Sensor Local Indicator Required Relay Contacts No NC

35 Air Temperature Sensor Required (2.4.1.2.4,h) Type

36 Leak Detection Required Outer Type and Description

37 High Flow Alarm Set Point GPM Low Flow Shutdown Set Point GPM

38 Provision for Pre-Start Purging (2.4.1.1,f)

39 Degree of Protection IP (2.4.1.2.1) IP Method of Cooling IC (2.4.2.6)

40 Other

41 Mounting

42 Horizontal: Foot Mounted Flange Mounted Flange Details

43 Vertical: Shaft Up Shaft Down P-base flange diameter

44 Baseplate: Furnished by (2.4.2.6): Soleplate: Furnished By (2.4.2.6)

45 Epoxy Grout to be Used (2.4.2.7.3): Manufacturer Type

46 Other
JOB NO. 0 ITEM / TAG NO. 0
INDUCTION MACHINE PURCHASE ORDER NO.
R API 541 4TH Edition -- DATA SHEETS REQ / SPEC NO. 0
E U.S. CUSTOMARY UNITS REVISION NO. 0 DATE 1/0/1900 BY 0
V PAGE 2 OF 6

GENERAL (CONT.)
DATA SHEET INDICATES INFO. TO BE BY MANUFACTURER BY MANUFACTURER BY MANUFACTURER OR
1 NOTE:
STATUS COMPLETED BY PURCH. WITH PROPOSAL AFTER ORDER PURCHASER AS APPLICABLE
2 Electrical System:

3 Primary Power Source 6600 Volts 3 Phase 60 Hz Maximum Ground Fault Amps

4 Method of System Grounding Resistance Reactance Ungrounded Solid


2
5 Fault Current at Machine Terminals (3.1.2) MVA Fused Starter Let-Through Energy (3.1.2) I t (Ampere-squared seconds)

6 Other

7 Motor Starting (2.2.3)

8 Loaded Unloaded Partially Loaded % Starting Torques in Excess of Nema or IEC (2.2.3.1) %

9 Load Reacceleration Required (2.2.2,b): NO YES Reacceleration Curve No.

10 If yes(2.2.3.4), Complete the following: Max Voltage Interruption Sec. Voltage at Motor Terminals volts

11 Other Starting Method Type Reduced Voltage volts

12 Starting Capacity Data(2.2.3.2): a. Min Volts at Machine Terminals Under Amps Inrush Current

13 or b. Min S.C. kVA and X/R ratio and volts at Machine Terminals

14 Adjustable Speed Drive Conditions:

15 ASD ASD with DOL Start Bypass @ Utility Frequency

16 Variable Torque Speed Range: Min Speed RPM lb-ft Max Speed RPM lb-ft

17 Constant Torque Speed Range: Min Speed RPM Max Speed RPM lb-ft

18 Constant Power Speed Range: Max Speed RPM HP

19 Other:

20 Bearings:

21 Bearing Type: Hydrodynamic(2.4.7.1.1) Anitfriction(2.4.7.1.3)

22 Momentary lbs Momentary lbs


Thrust Bearing(2.4.7.1.5) Max Driven Equipment Thrust Downthrust Upthrust
23 Continuous lbs Continuous lbs

24 Bearing Constant-Level Sight Feed Oilers Required(2.4.7.2.2) Bearing Housing Heaters Required(2.4.8.3)

25 Special Seals for Gas Purge(2.4.7.3a) Non-Conducting Seals(2.4.7.3,b)

26 Other:

LUBRICATION SYSTEM
27 SELF-LUBE(2.4.8.1) Pressurized Lube Required(2.4.8.1) System Supplied By: Siemens Common With Driven Equipment

28 Per API 614(2.4.8.6) Main Oil Pump Required: Integral Shaft Driven Separate (See Line 29)

29 Oil Rings Not Provided If Separate: Vertical Horizontal Type of Drive: Motor Steam Turbine

30 Standby Oil Pump Required(2.4.8.5): Vertical Horizontal Type of Drive: Motor Steam Turbine
o o
31 Turbine Driver: Pressure PSIG Temperature Range F to F

32 Electric Motor Driver: Std. No. Encl. HP RPM volts Phase Hz

33 Oil Cooler Required(2.4.7.1.14): Water Cooled Air Cooled Construction Details

34 Type/Viscosity of Oil Pressure(2.4.8.4; 2.4.8.5 and 2.4.8.8)

35 Beating Oil Requirements(6.1.5): 0.15 GPM 20 PSI Heat Loss to be Removed 1 kW

36 Oil Viscosity When Common Oil System is Used

37 Antifriction Bearings: Grease: Type Oil Mist(2.4.7.4) Pure Mist Purge Mist

38 Other:

SPECIAL CONDITIONS:
39 Shaft and Spider one piece forging for 4 or more poles(2.4.5.1.2,b; 2.4.5.1.4)

40 Special Vibration Requirements(4.3.3.9)

41 Efficiency Evaluation Factor (EF)(6.1.1) $/kW applied at % of F.L.

42 Federal, State, or Local Codes(2.1.7):

43 External Forces on Motor Housing That May Affect Site Performance(2.1.13.2.4.4):

44 Other:
JOB NO. 0 ITEM / TAG NO. 0
INDUCTION MACHINE PURCHASE ORDER NO.
R API 541 4TH Edition -- DATA SHEETS REQ / SPEC NO. 0
E U.S. CUSTOMARY UNITS REVISION NO. 0 DATE 1/0/1900 BY 0
V PAGE 3 OF 6
MAIN CONDUIT BOX
DATA SHEET INDICATES INFO. TO BE BY MANUFACTURER BY MANUFACTURER BY MANUFACTURER OR
1 NOTE:
STATUS COMPLETED BY PURCH. WITH PROPOSAL AFTER ORDER PURCHASER AS APPLICABLE
2 MAIN TERMINAL BOX(3.1):

3 BOX LOCATION CONDUCTOR SIZE TYPE INSULATION QTY. PER PHASE

4 BUSHING STUDS OR RECEPTACLES(3.1.6,h) TERMINATIONS AND INTERIOR JUMPERS: INSULATED NON-INSULATED

5 SPACES FOR STRESS CONES(3.1.6,g) CABLE ENTERING FROM(3.1.4): TOP BOTTOM DRIVE SIDE NON-DRIVE END SIDE

6 SPACE HEATERS(3.1.6,b): TEMP. CODE THERMAL INSULATION(3.1.6a) 120/240 VOLTS 1 PHASE 0.15 kW

7 DIFFERENTIAL PROTECTION CURRENT TRANSFORMERS(3.1.6,j; 3.1.8; 3.6.3): ACCURACY CLASS RATIO QUANTITY

8 TYPE: CORE BALANCE FULL DIFFERENTIAL SUPPLIED BY MOUNTED BY

9 SURGE CAPACITORS(3.1.6,I; 3.6.2.1): MICRO FARADS SUPPLIED BY MOUNTED BY

10 SURGE ARRESTERS(3.1.6,I; 3.6.2.2): kV RATED SUPPLIED BY MOUNTED BY

11 CURRENT TRANSFORMERS(3.1.6,j) FOR AMMETER ACCURACY CLASS RATIO QUANTITY

12 SUPPLIED BY MOUNTED BY

13 POTENTIAL TRANSFORMERS(3.1.6,i) FOR VOLTMETER ACCURACY CLASS RATIO QUANTITY

14 FUSES REQUIRED SUPPLIED BY MOUNTED BY

15 PRESSURE WITHSTAND CAPABILITY(3.1.2) DRAINS(3.1.6,c) BREATHERS(3.1.6,d) PROVISIONS FOR PURGING(3.1.6,e)

16 REMOVABLE LINKS(3.1.6,f) SILVER OR TIN-PLATED BUS JOINTS(3.1.6,k) GROUND BUS(3.1.6,m)

17 OTHER:

ACCESSORIES
18 FRAME SPACE HEATERS(3.4): TEMP CODE T3 SHEATH MATERIAL Flexible 120/240V VOLTS 1 PHASE 0.525 kW

19 BEARING HEATERS(2.4.8.3): VOLTS PHASE kW

20 WINDING TEMPERATURE DETECTORS(3.2.1): GROUND ONE COMMON LEAD(3.2.1.2)

21 OTHER DETECTOR: QTY/PHASE 2 TYPE RTD MATERIAL PLATINUM WIRES 3


o o
22 RECOMMENDED SETTINGS ALARM 311 F SHUTDOWN 338 F

23 HYDRODYNAMIC & THRUST BEARING TEMPERATURE DEVICES(3.3): INSTALL PER API 670

24 RTDs QTY/BRG. 1 TYPE RTD MATERIAL PLATINUM WIRES 6 GROUND ONE COMMON LEAD(3.2.1.2)

25 THERMOCOUPLE: QTY/BRG. TYPE MATERIAL WIRES

26 DIAL TYPE THERMOMETERS(2.4.7.1.16): TYPE ALARM CONTACTS NUMBER OF CONTACTS NO NC

27 LOCATION OF BEARING TEMPERATURE SENSOR WIRE TERMINATIONS: TERMINAL BOX AT MOTOR SIDE STATOR RTD BOX CONDUIT HEAD AT BEARING
o o
28 RECOMMENDED SETTINGS ALARM 212 F SHUTDOWN 221 F

29 VIBRATION DETECTORS(3.8): INSTALLED QTY/BEARING: TWO(3.8.1) FOUR(3.8.1)

30 PHASE REFERENCE PROBE(3.8.1) PROVISIONS ONLY INSTALLED

31 PROBE, OSCILLATOR-DEMODULATOR MFR. Bently-Nevada MODEL/SERIES 3300 XL 8mm

32 PROBE SUPPLIED BY Bently-Nevada INSTALLED BY Siemens OSC-DEMOD. FURNISHED BY INSTALLED BY

33 BEARING HOUSING SEISMIC SENSORS(3.8.3) PROVISIONS ONLY INSTALLED SENSOR TYPE SENSOR MFR.

34 QTY/D.E. BEARING LOCATION (H,V,A) QTY./N.D.E. BEARING LOCATION (H,V,A)

35 SENSOR SUPPLIED BY INSTALLED BY TRANSDUCER FURNISHED BY INSTALLED BY

36 LOCATION OF VIBRATION SENSOR WIRE TERMINATIONS: TERMINAL BOX AT MOTOR SIDE WITHIN STATOR HOUSING OTHER

37 ALARM AND CONTROL SWITCHES(3.6.1): SPDT 10 AMP 115 VOLT DC RATED CONTACTS:

38 PARTIAL DISCHARGE DETECTORS(3.4.6) YES DESCRIBE REQUIRED SYSTEM:

39
40 SEPERATELY POWERED AUXILLIARY FAN(S): DRIVER INFORMATION (WHERE APPLICABLE) STANDARD NO.

41 QUANTITY LOCATION ENCL. HP RPM VOLTS PHASE Hz

42 QUANTITY LOCATION ENCL. HP RPM VOLTS PHASE Hz

43 OTHER:

44
45
JOB NO. 0 ITEM / TAG NO. 0
INDUCTION MACHINE PURCHASE ORDER NO.
API 541 4TH Edition -- DATA SHEETS REQ / SPEC NO. 0
R U.S. CUSTOMARY UNITS REVISION NO. 0 DATE 1/0/1900 BY 0
E PAGE 4 OF 6
V
1 GENERAL
DATA SHEET INDICATES INFO. TO BE BY MANUFACTURER BY MANUFACTURER BY MANUFACTURER OR
2 NOTE:
STATUS COMPLETED BY PURCH. WITH PROPOSAL AFTER ORDER PURCHASER AS APPLICABLE

3 DRIVEN EQUIPMENT INFORMATION

4 DRIVEN EQUIPMENT: Tag No. Description Location

5 TYPE OF LOAD: Centrifugal: Compressor Pump Fan

6 Positive Displacement: Recipricating Compressor Plunger Pump

7 Other: Description:

8 DRIVEN EQUIPMENT MFR. Type/Model No. RPM

9 LOAD SPEED-TORQUE CURVE NO.(2.2.2a) Crank-Effort Chart or Torque-Effort Curve No. (6.1.4g)

10 TOTAL DRIVEN-EQUIPMENT WK2 (2.2.2c) lb-ft2 at RPM

11 DRIVER CONNECTION TO LOAD: Direct Coupled V-Belt Connection Through Gearbox

12 MOTOR SHAFT EXTENSION(2.4.5.1.9): Cylindrical Fit Taper Fit Flange

13 ROTATION VIEWED FROM OPPOSITE DRIVE END OF MOTOR: Clockwise Counterclockwise Bi-Directional

14 COUPLING(2.4.9): Type Mfr Type/Model

15 SUPPLIED BY: Motor Mfr Driven Equipment Mfr Purchaser Others

16 MOUNTED BY: Motor Mfr Driven Equipment Mfr Purchaser Others


17 OTHER:

18 MISCELLANEOUS
19 PROOF OF NONSPARKING, CORROSION-RESISTANT FAN(2.4.10.6) Quantity of Special Tools Required(2.1.11; 2.4.2.14)

20 SPECIAL LOW-TEMP MATERIAL REQUIREMENTS(2.4.10.4)

21 SPECIAL WINTERIZING REQUIREMENTS(6.1.16)

22 MATERIALS TO BE IDENTIFIED WITH ANSI, ASTM, AISI, ISO, OR ASME NUMBERS(6.1.19)

23 TYPICAL DRAWINGS AND LITERATURE WITH PROPOSAL Electronic Instruction Manuals (6.1.19) Photos showing assembly steps required (6.2.4.5)

24 SPECIAL IDENTIFICATION WITH TRANSMITTALS(6.2.1.2,e)

25

26

27 SHIPMENT: Domestic Export Boxing Required Commissioning Assistance Required(6.1.18)


28 OTHER:

29 MOTOR DATA - FIRST SECTION


30 MANUFACTURER SIEMENS Type/Model No. CGII Frame Size/Designation 5810S

31 QTY. 2 800 HP 3600 RPM(Syn.) 2 Poles 6600 Volts 3 Phase 60 Hz

32 SERVICE FACTOR 1.15 INSULATION CLASS F-VPI TEMPERATURE RISE B ENCLOSURE WPII

33 FULL LOAD SPEED 3561 RPM FULL-LOAD TORQUE (FLT) 1180 FT-LB ROTOR WK2 (6.1.4.1,c) 164.2 LB-FT2 AT FLRPM

34 LOCKED ROTOR TORQUE (LRT) 95 % FLT PULL-UP TORQUE (PUT) 95 % FLT BREAKDOWN TORQUE (BDT) 228 % FLT

35 LOAD POINT 50% 75% 100% OTHER: 115 %

36 EFFICIENCY 94.2 94.5 94.3 93.9 GUAR. EFF. @ 94.1 % LOAD = 100

37 POWER FACTOR 89.2 91.6 91.9 91.6 TEST METHOD

38 CURRENT 31.1 AMPS 45.2 AMPS 60.3 AMPS 69.8 AMPS

39 MOTOR SPEED-TORQUE CURVE NO. Provided separate MOTOR SPEED-CURRENT CURVE NO.

40 MOTOR SPEED-POWER FACTOR CURVE NO. FOR CURRENT-PULSATION OPERATING COND. (6.1.4,g) % PULSATION

41 100% OTHER: 80

42 LOCKED-ROTOR CURRENT 375 AMPS 300 AMPS LOCKED ROTOR PF 20.4

43 LOCKED-ROTOR WITHSTAND TIME, COLD 12 SEC. 21 SEC. MAX SOUND PRESSURE LEVEL(2.1.3) 81 dBA @ 3'
no-load
44 LOCKED-ROTOR WITHSTAND TIME, RATED TEMP 10 SEC. 18 SEC.

45 WEIGHTS: NET 6450 lb STATOR lb ROTOR 1115 lb SHIPPING 6900 lb

46 OTHER:

49

50

51
52
JOB NO. 0 ITEM / TAG NO. 0
INDUCTION MACHINE PURCHASE ORDER NO.
R API 541 4TH Edition -- DATA SHEETS REQ / SPEC NO. 0
E U.S. CUSTOMARY UNITS REVISION NO. 0 DATE 1/0/1900 BY 0
V PAGE 5 OF 6
1 MOTOR DATA - SECOND SECTION
DATA SHEET INDICATES INFO. TO BE BY MANUFACTURER BY MANUFACTURER BY MANUFACTURER OR
2 NOTE:
STATUS COMPLETED BY PURCH. WITH PROPOSAL AFTER ORDER PURCHASER AS APPLICABLE
3 BEARINGS:

4 BEARING, DRIVE END: CAPABLE OF SELF LUBE: yes MFG: Siemens TYPE: Sleeve MODEL/PART NO.: 54-354-010-501

5 BORE DIAMETER: MIN: 3.000 IN MAX: 3.001 IN BORE LENGTH: 2.70 IN

6 DESIGN CLEARANCE WITH SHAFT: MIN: 0.005 IN MAX: 0.007 IN BEARING LOADING: 68.8 PSI

7 BRG, NON-DRIVE END: CAPABLE OF SELF LUBE: yes MFG: Siemens TYPE: Sleeve MODEL/PART NO.: 54-354-010-501
8 BORE DIAMETER: MIN: 3.000 IN MAX: 3.001 IN BORE LENGTH: 2.70 IN

9 DESIGN CLEARANCE WITH SHAFT: MIN: 0.005 IN MAX: 0.007 IN BEARING LOADING: 68.8 PSI

10 THRUST BEARING: NON-DRIVE END MANUFACTURER: TYPE: MODEL/PART NO.:

11 DRIVE END BEARING LOADING: PSI

12 OTHER:

13 INDUCTION MOTOR EQUIVALENT CIRCUIT DATA:


o
14 689 KVA BASE AT RATED VOLTAGE AND 77 F SUBTRANSIENT REACTANCE X"D: 10.38

15 TOTAL WINDING CAPACITANCE TO GROUND: 0.015 uF

16 LOCKED ROTOR AT RATED VOLTAGE: STATOR R: 0.83 ROTOR R: 1.67 MAGN R:

17 STATOR X: 7.25 ROTOR X: 4.47 MAGN X:

18 RATED LOAD AT RATED VOLTAGE: STATOR R: 0.83 ROTOR R: 0.686 MAGN R: 365

19 STATOR X: 7.25 ROTOR X: 112 MAGN X: 9640

20 RESIDUAL VOLTAGE OPEN-CIRCUIT TIME CONSTANT: MOTOR ONLY: 1.426 SEC

21 MOTOR WITH SURGE CAPACITORS: SEC


o
22 PHASE-TO-PHASE RESISTANCE: 1.268 OHM, @ 77 F

23 OTHER:

STATOR AND ROTOR WINDING REPAIR DATA

24 STATOR COIL INFORMATION:

25 TOTAL COPPER WEIGHT: LB COPPER STRAND SIZE: INSULATION:

26 NUMBER OF STRANDS PER COIL TURN: TURN INSULATION DESCRIPTION:

27 NUMBER OF TURNS PER COIL: COIL GROUND-WALL INSULATION DESCRIPTION:

28 COIL CONFIGURATION: ROWS BY: COLUMNS

29 FINISHED COIL DIMENSION IN SLOT REGION, W x H x L (ALSO GIVE TOLERANCES):

30 TOTAL NUMBER OF STATOR SLOTS:

31 SLOT FILLER DESCRIPTION - THICKNESS: TOP: SIDE: BETWEEN TOP-BOTTOM COILS:

32 STATOR BORE DIAMETER: WINDING THROW WINDING CONNECTION:

33 SPECIAL END-TURN BRACING:

34 COIL DIMENSION DRAWING NO.:

35 OTHER: Stator winding information proprietary to Siemens

36 ROTOR CAGE INFORMATION:

37 TOTAL COPPER WEIGHT: LB BAR SIZE: CONDUCTOR MATERIAL: NO. OF BARS:

41 RETAINING RING ALLOW, IF APPLICABLE:

42 RING MATERIAL: RING DIMENSIONS PRE-MACHINING:

43 OTHER: Rotor cage information proprietary to Siemens

MISCELLANEOUS

44
45
46
47
48
JOB NO. 0 ITEM / TAG NO. 0
INDUCTION MACHINE PURCHASE ORDER NO.
R API 541 4TH Edition -- DATA SHEETS REQ / SPEC NO. 0
E U.S. CUSTOMARY UNITS REVISION NO. 0 DATE 1/0/1900 BY 0
V PAGE 6 OF 6
1 ANALYSIS, SHOP INSPECTION, AND TESTS
2 REQUIRED WITNESSED OBSERVED
3 ACCEPTANCE CRITERIA: (4.1.3.3) (4.1.3.1) (4.1.3.2)

4 DESIGN REVIEW (6.2.1.4)

5 TORSIONAL ANALYSIS (2.4.6.2.4) BY

6 LATERAL CRITICAL SPREED ANALYSIS (2.4.6.2.1)

7 SHOP INSPECTION (4.1.1)

8 SUBMIT TEST PROCEDURES 6 WEEKS BEFORE TESTS (4.3.1.5)

9 INSPECTION FOR CLEANLINESS PER API 614 (4.2.3.2; 4.2.3.3)

10 OBSERVANCE OF ASSEMBLY/DISMANTLING(4.3.1.1)

11 DEMONSTRATE ACCURACY OF TEST EQUIPMENT(4.3.1.14)

12 STATOR CORE TEST(4.3.4.1)

13 SURGE COMPARISON TEST(4.3.4.2)

14 SPECIAL SURGE TEST OF COILS(4.3.4.2.1)

15 COMPLONENT BALANCE((2.4.6.3.1)

16 FINAL BALANCE(4.3.1.6.1)

17 RESIDUAL UNBALANCE VERIFICATION TEST(2.4.6.3.6; 6.2.5.1,a)

18 BALANCE CHECK WITH HALF COUPLING(2.4.6.3.3)

19 RUNNING TESTS WITH COUPLING HALF(2.4.6.3.3; 4.3.1.6)

20 STATOR INSPECTION PRIOR TO VPI(4.3.4.5)

21 SEALED WINDING CONFORMANCE TEST(4.3.4.4)

22 POWER FACTOR TIP-UP TEST(4.3.4.3)

23 BEARING DIMENSIONAL & ALIGNMENT CHECKS BEFORE TESTS(4.3.2.1,j)

24 VIBRATION RECORDING(4.3.3.12)

25 COMPLETE TEST(4.3.5.1.1)

26 EFFICIENCY(4.3.5.1.1,a)

27 LOCKED ROTOR(4.3.5.1.1,b)

28 HEAT RUN(4.3.5.1.1,e)

29 SOUND PRESSURE LEVEL TEST(4.3.5.1.1,g)

30 BEARING DIMENSIONAL & ALIGNMENT CHECKS AFTER TESTS(4.3.2.1,k)

31 DC HIGH-POTENTIAL TEST(4.3.5.1.2)

32 UNBALANCED RESPONSE(4.3.5.3)

33 BEARING HOUSING NATURAL FREQUENCY TESTS(4.3.5.4)

34 FINAL ASSEMBLY RUNNING CLEARANCES(4.2.1.1,e)

35 MATERIAL INSPECTION(4.2.2)

36 RADIOGRAPHIC TEST(4.2.2.2) PARTS

37 ULTRASONIC TEST(4.2.2.3) PARTS

38 ULTRASONIC INSPECTION OF SHAFT FORGING(2.4.5.1.8)

39 MAGNETIC PARTICLE TEST(4.2.2.4) PARTS

40 LIQUID PENETRANT TEST(4.2.2.5) PARTS

41 RATED ROTOR TEMPERATURE VIBRATION TEST(4.3.5.2.1)

42 OTHER

43 COMMENTS
44
45
46
47
48
49
50

You might also like