Smart Digital Latest
Smart Digital Latest
SMART Digital
DIGITAL DOSING
1. General data 3
Table of contents
Performance range 3
Features at a glance 4
2. Identification 6
Type key 6
3. Functions 7
Overview of functions 7
Functional description 8
Control cube DDA and DDC 9
Menu 10
Operation modes 11
Functions 13
Wiring diagram, DDA 19
Wiring diagram, DDC 20
Wiring diagram, DDE-PR, -P 21
4. Construction 22
DDA and DDC 22
DDE 23
5. Dimensions 24
DDA and DDC 24
DDE 24
6. Technical data 25
DDA 25
DDC 26
DDE 27
7. Pump selection 28
DDA, standard range 28
DDC, standard range 29
DDE, standard range 30
DDA, DDC, DDE, non-standard range 31
9. Pumped liquids 55
2
SMART Digital
1
1. General data
General data
Performance range
P
[bar]
16
DDA 7.5-16
10
DDC 6-10 DDA 12-10
DDE 6-10
7
DDC 9-7 DDA 17-7
4
DDC 15-4 DDA 30-4
DDE 15-4
3
SMART Digital
1
Features at a glance Precise and easy setting / usability and interaction
General data
Digital DosingTM
The SMART Digital generation DDA, DDC and DDE
with powerful variable-speed stepper motor brings
state-of-the-art technology to perfection.
Combined expert knowledge and the patented
redundant.
Designed to save costs
In general, the investment for a dosing pump
installation is low compared to its life cycle costs
Fig. 3 Modularity of the control cube
including the cost of the chemicals. The following
A turn-down ratio of up to 1:3000, a wide supply features make the SMART Digital DDA, DDC and DDE
voltage range (100-240 V; 50/60 Hz), combined pumps contribute to low life cycle costs:
connection sets and other features reduce the models No underdosing or overdosing due to high dosing
and variants to a minimum. accuracy and FlowControl
Longer maintenance intervals thanks to the
universal chemical resistance of the full-PTFE
diaphragm
Reduced energy consumption thanks to
state-of-the-art drive technology.
4
SMART Digital
1
Three application-oriented type ranges
General data
DDA: High-end pump range for extended flow and
pressure ranges with sensor-based FlowControl and
measurement functions for challenging industrial
applications, e.g.
Process water
Food and beverage
Ultrafiltration and reverse osmosis
Pulp and paper
Boiler feed water
CIP (Cleaning-In-Place).
DDC: User-friendly pump range with standard inputs
and outputs for common applications, e.g.
Drinking water
Waste water
Swimming pool water
Cooling tower
Chemical industry.
DDE: Low-budget pump range with basic functions
including manual operation or control via PLC for OEM
applications, e.g.
Car wash
Irrigation.
5
SMART Digital
2
2. Identification
Identification
Type key
Example: DDA 7.5- 16 AR- PP /V /C -F -3 1 U2U2 F G
DDC
Design
DDE
G Grundfos
Maximum flow [l/h]
Mains plug
Valve type
Valve ball material
1 Standard
C Ceramic 2 Spring-loaded
SS Stainless steel 1.4401 0.1 bar suction opening pressure
0.1 bar discharge opening pressure
Control cube position
Supply voltage
F Front-mounted (change to left and right possible)
X No control cube (DDE) 3 1 x 100-240 V, 50/60 Hz
* Including 2 pump connections, foot valve, injection unit, 6 m PE discharge hose, 2 m PVC suction hose, 2 m PVC deaeration hose (4/6 mm)
** PVC dosing heads only up to 10 bar
6
SMART Digital
3
3. Functions
Functions
Overview of functions
DDA DDC DDE
General
Digital Dosing: Internal stroke speed and frequency control
Mounting plate (basic/wall mounting)
Control panel, see page 9
Control cube mountable in three positions: front, left, right
Control panel position: front-fitted
Transparent protective cover for control elements
Capacity setting in millilitres, litres or US-gallons
Graphical display with background light in four colours for status
indication: white, green, yellow, red
Plain-text menu in different languages
Turn-and-push knob (click wheel) for easy navigation
Capacity adjustment knob (0.1 - 100 %)
Start/Stop key
100 % key (deaearation)
Operation mode switch (manual/pulse)
Operation modes, see page 11
Manual speed control
Pulse control in ml/pulse
Pulse control (1:n)
Analog control 0/4-20 mA
Batch control (pulse-based)
Dosing timer cycle
Dosing timer week
Fieldbus control
Functions, see page 13
Auto deaeration also during pump standby
FlowControl system with selective fault diagnosis
Pressure monitoring (min/max)
Flow measurement
AutoFlowAdapt
SlowMode (anti-cavitation)
Calibration mode
Scaling of analog input
Service information display
Relay setting: alarm, warning, stroke signal, pump dosing, pulse input*
Relay setting (additionally): timer cycle, timer week
Inputs/outputs, see page 14
Input for external stop
Input for pulse control
Input for analog 0/4-20 mA control
Input for low-level signal
Input for empty tank signal
Output relay (2 relays)
Output analog 0/4-20 mA
Input/Output for GENIbus
Input/Output for E-box (e.g. E-box 150 with Profibus DP)
* DDE-PR: relay 1: alarm; relay 2: low-level signal, stroke signal, pulse input
7
SMART Digital
3
Functional description
Functions
Suction
Discharge
50 % - Duration
Suction
Discharge
10 % -
Duration
Suction
TM04 1481 0410
Discharge
10 % 50 % Duration
8
SMART Digital
3
Control cube DDA and DDC Operating elements DDE
Functions
DDA and DDC pumps are supplied with front-mounted
control cube. The position of the control cube can
1
easily be changed by unfastening 2 screws, lifting the 3 4 5
2
cube, turning it to the left or to the right and fastening 1
1.5 6
8 10
2
both screws again. 0.8
0.6 15
0.5 20 3
0.4
0.3
30 4
40
0.2 50
3
When holding down the operation mode switch, the
4 pump changes from manual operation to pulse mode
or vice versa.
If the maximum capacity is required over a short period
Fig. 7 Operating elements DDA and DDC of time, for example during start-up, press the 100 %
key.
Pos. Description Depending on the selected operation mode, the
1 Graphical LC display respective status LED (pulse or manual) is activated
2 Click wheel according to the following table:
3 100 % key (deaeration)
LED colour Pump status
4 Start/Stop key
Green (flashing) Stopped
The click wheel guides the user quickly and easily Green Running
through the plain-text menu. Red-green (flashing) External stop
If the maximum capacity is required over a short period Yellow Low level (warning)
Red Empty tank (alarm)
of time, for example during start-up, press the 100 %
Red (flashing) Motor blocked (alarm)
key. To set the pump to run for a specific number of
seconds at maximum capacity, press the 100 % key
and turn the click wheel clockwise simultaneously.
9
SMART Digital
3
Menu
Functions
The DDA and DDC dosing pumps feature a user-friendly plain-text menu. The menu consists of 4 tabs: Operation;
Info; Alarm; Setup. During initial start-up, all menu text appears in the English language. The menu can be
set to display other languages.
This example applies to DDA pumps:
Operation
7.50 l/h
Manual 7.49 l/h
Setup Info
Language English > Fr 12.12.2009 12:34
Operation mode Manual > Counter >
Analog output Input > Service -
SlowMode Off > Service kit
............................. .............................
Alarm
1 12.12.2009 13:34
The menu text appears in up to 29 languages on a big graphical display, backlit in four different colours according to
the traffic light concept.
Display Fault Pump status
White - Stop Standby
Green - Running
Yellow Warning Stop Standby Running
Red Alarm Stop Standby
10
SMART Digital
3
Operation modes Applies to DDE-PR, DDE-P control variant
Functions
The dosing quantity per pulse is adjusted with the
Manual control adjustment knob according to the scale from 0.1 to
100 % of the stroke volume. The pump adjusts its
The pump ensures constant dosing according to
speed according to two factors:
the quantity set in l/h or ml/h or gph by means of the
click wheel. The pump automatically changes between the frequency of external pulses
the measuring units. the set percentage of stroke volume.
Setting range Setting range, DDE-PR, DDE-P
40
I1 / Q 1
20
TM04 1575 1410
I2' / Q ' 2
0
0 4 8 12 16 20 [mA]
Input signal
11
SMART Digital
3
Pulse-based batch control Dosing timer week
Functions
Setting range
1 1 1 1
6:00
Setting range 4 4
Pump type From
To [l/batch] Resolution [ml]* 12:00
[ml/batch]
DDA 7.5-16 0.74 999 0.09 2 2
Batch volume
t1 t1
TM04 1577 1410
t2
t3
Setting range
The batch volume setting range corresponds to the
pulse-based batch control setting range.
12
SMART Digital
3
Functions External stop
Functions
Applies to DDA, DDC, DDE-PR, DDE-P
SlowMode With the external stop function, the pump can be
Applies to DDA, DDC stopped from a remote place by an external contact
When the SlowMode function (anti-cavitation) is signal. It is not recommended to switch on and off the
selected, the pump extends and smooths its suction power supply as it was usual when working with a
stroke. This results in a softer suction stroke. conventional dosing pump. When working with
microprocessor-controlled digital dosing pumps, the
The SlowMode function is used in these situations:
external stop signal has to be used, in order to keep
when pumping high-viscosity liquids the optimal dosing precision and to prevent damages
when pumping degassing liquids to the electronics.
when the suction line is long When activating the external stop contact, the pump
when the suction lift is high. changes from running to standby . The operation
Depending on the application, the motor speed during display shows an activated external stop .
the suction stroke can be reduced individually to The signal input can be set to normally open (default)
approximately 50 % or 25 % of the normal motor or normally closed contact.
speed.
The maximum pump capacity is reduced accordingly.
Counters
See pages 25 and 26 for further details. Applies to DDA and DDC
The pump displays resettable and non-resettable
Auto deaeration counters in the info menu tab.
Applies to DDA
Counter Description Resettable
The auto deaeration function avoids breakdown of the Accumulated dosed quantity in litres or
dosing process due to air-locking, when dosing Volume Yes
US gallons
degassing liquids such as sodium hypochlorite. Operating Accumulated number of operating hours
No
During long dosing breaks, e.g. at the weekend or hours (power-on)
Motor Accumulated number of motor runtime
overnight, air-bubbles can form in the suction line and runtime hours
No
get into the dosing head. If too much air is in the Strokes Accumulated number of dosing strokes No
dosing head, and the dosing process is started again, Accumulated number of times the mains
Power on/off No
no liquid will be dosed (air-lock). Software-controlled supply has been switched on
diaphragm movements at regular intervals encourage
the air bubbles to rise and finally to be displaced out of
the dosing head.
These movements are executed
when the pump is not stopped and
during dosing breaks (e.g. external stop or no
incoming pulses).
Calibration
Applies to DDA and DDC
The pump is calibrated in the factory at the nominal
pressure of the respective pump type (see maximum
pressure Technical data page 25, 26). After start-up,
the dosing pump can be calibrated for the actual
installation to ensure that the displayed value (ml, l or
gph) is correct. A calibration program in the setup
menu facilitates this process. The AutoFlowAdapt
function keeps the dosing precision (DDA-FCM control
variant), even if the backpressure changes.
For the description of the AutoFlowAdapt function, see
page 18.
13
SMART Digital
3
Service display Relay output
Functions
In case of difficult liquids, e.g. with abrasive particles, Applies to DDE-PR control variant
the service intervals can be shorter and service has to Signal
be performed earlier. Description
Relay 1 Relay 2
* Depending on the pump model and settings, the relay outputs can
be activated (see Relay output, page 14)
14
SMART Digital
3
Analog output Key lock and mechanical lock
Functions
Applies to DDA Applies to DDA, DDC
In addition to the analog input (operation mode: analog To protect the pump from maloperation, a key lock can
0/4-20 mA) the pump is also equipped with an analog be set by entering a 4-digit PIN-code. When the pump
0/4-20 mA output signal. Depending on the process is locked, it is still possible to navigate through the
control requirements, the following analog output menus Alarm and Info and to acknowledge
settings are available: alarms. Two levels of protection are available:
Control variant Settings: the keys and 100% are still available.
Description of analog
Setting
output signal FCM FC AR Settings + keys: the keys and 100% are also
Mapped 1:1 to the analog locked.
Output = Input input, e.g. used in X X X For temporary (2 minutes) or final deactivation the
master-slave applications
preset 4-digit pin-code has to be entered again.
Flow measured in the dosing
Actual flow head X X* X* Applies to DDE
(Flow Measurement page 18)
The adjustment knob can be locked with a locking
Backpressure measured in
Backpressure the dosing head X X screw to fix the current setting.
(Pressure monitoring page 18)
Set by a command in the bus Basic settings
Bus control X X X
communication (see below)
Applies to DDA, DDC
* Output signal is calculated based on motor speed and pump status
(target flow rate). With load factory settings, the pump can be reset to
the default settings. In addition, with save customer
Bus communication settings, the current configuration of the pump is
Applies to DDA stored and can be activated later by load customer
settings. The latest saved configuration is stored in the
The pump is equipped with a built-in module for
memory.
GENIbus communication. With the additional E-Box
150 module (please see page 36) the pump can be
Units
integrated into a Profibus DP network.
The bus communication possibilities enable remote Applies to DDA, DDC
monitoring and setting via the fieldbus system. It is possible to select metric units (litre/millilitre/bar) or
US units (US gallons/psi). Depending on the operation
mode and menu, the following units are displayed:
Operation mode/Function Metric units US units
Manual control ml/h or l/h gph
Pulse control ml/ ml/
Analog 0/4-20 mA control ml/h or l/h gph
Batch control
ml or l gal
TM04 1640 2110
(pulse- or timer-based)
Calibration ml ml
Volume counter l gal
Pressure monitoring bar psi
15
SMART Digital
3
Additional display FlowControl
Functions
Additional display The pump monitors the dosing process of liquids when
the FlowControl function is activated. Although the
Fig. 16 Additional display pump is still operating, some influences such as air
bubbles may cause reduced flow rates or even stop
The following additional information can be selected: the dosing process. For optimal process safety and
reliability, the activated FlowControl function
Settings Description
immediately detects and displays the following
Depending on the operation mode:
malfunctions:
Actual flow (manual, pulse) 1) Overpressure
Target flow (pulse) Discharge line burst
Default display Air bubbles in the dosing head
Input current (analog) 4)
Cavitation at the suction side
Remaining batch volume (batch, timer) 3)
Suction valve leakage
Time until next batch (timer) 3) Discharge valve leakage.
Dosed volume Total dosed volume (Counters see page 13) The unique FlowControl is based on an intelligent and
Actual flow Actually measured flow 1) maintenance-free sensor integrated in the dosing
Backpressure Current backpressure in the dosing head 2) head. During the dosing process, the sensor measures
1) Only DDA-FCM control variant the actual pressure and sends the measured value to
2) Only DDA-FCM/FC control variant the microprocessor in the pump. An internal indicator
3) Only DDA pumps diagram is generated combining the actual pressure
4) Only DDA pumps and DDC-AR control variant
value with the diaphragm position (stroke length).
With it, the dosing process is monitored, as the
different malfunctions can immediately be detected
due to their specific deviations in the curve.
Compressible air bubbles, for instance, will reduce the
discharge phase and the stroke volume (see fig. 18).
The sensitivity and the delay of the FlowControl
function can be adjusted individually.
FlowControl requires a minimum backpressure of
2 bar. Grundfos recommend an additional
spring-loaded valve (approx. 3 bar) on the discharge
side for dosing low capacities (< 1 l/h) (please see
page 45).
16
SMART Digital
3
Functions
Pressure
1
3
1 Compression phase
2 Discharge phase
3 Expansion phase
4 Suction phase
17
SMART Digital
3
Pressure monitoring AutoFlowAdapt
Functions
18
SMART Digital
3
Wiring diagram, DDA
Functions
2 1 2 1
3 4 3 4
4 3 2 1
5
1 2 3 4
Sensor
Pin holes
Function Plug type
1/brown 2/white 3/blue 4/black
Analog GND/ (-) mA (+) mA mA signal
External stop GND X Contact
Pulse GND X Contact
Pin holes
Function Plug type
1 2 3 4
Low level X GND Contact
Empty tank X GND Contact
Pin holes
Function Plug type
1/brown 2/white 3/blue 4/black 5/yellow-green
GENIbus +30 V GENI bus A GENI bus B GND Bus
Analog output (+) mA GND/ (-) mA mA signal
Pin holes
Function Plug type
1/brown 2/white 3/blue 4/black
Relay 1 X X Contact
Relay 2 X X Contact
19
SMART Digital
3
Wiring diagram, DDC
Functions
2 1 2 1
3 4 3 4
4 3
1 2
4 3
3 3 4 2
2 2 1
1 1 GND
2
GND 1
Pin holes
Function Plug type
1/brown 2/white 3/blue 4/black
Analog* GND/ (-) mA (+) mA mA signal
External stop GND X Contact
Pulse GND X Contact
Pin holes
Function Plug type
1 2 3 4
Low level X GND Contact
Empty tank X GND Contact
Pin holes
Function Plug type
1/brown 2/white 3/blue 4/black
Relay 1 X X Contact
Relay 2 X X Contact
* applies to DDC-AR
20
SMART Digital
3
Wiring diagram, DDE-PR, -P
Functions
2 1
3 4
4 3 2 1
1 2 3 4
4 3
3 3 4 2
2 1
1 GND
1
GND
2
1
Pin holes
Function Plug type
1/brown 2/white 3/blue 4/black
External stop GND X Contact
Pulse GND X Contact
Pin holes
Function Plug type
1 2 3 4
Low level X GND Contact
Empty tank X GND Contact
Pin holes
Function Plug type
1/brown 2/white 3/blue 4/black
Relay 1 (Alarm) X X Contact
Relay 2 (see page 14) X X Contact
* applies to DDE-PR
21
SMART Digital
4
4. Construction
Construction
13 14 15 16 17 18 19 20 21 22 23 24
12
11
25
10
9
26
8
7
6
27
5
28
4
22
SMART Digital
4
DDE
Construction
11 12 13 14 15 16 17 18 19 20
10
21
7
6
5
22
4
23
SMART Digital
5
5. Dimensions
Dimensions
17.5 110 A1
G 5/8
100%
200.8
B
DDE
A1
161.5
C
105 D 161 17
TM04 1598 0312
4 x 6
120
DDA 7.5-16
DDC 6-10
280 251 196 46.5 24
DDC 9-7
DDE 6-10
DDA 12-10
DDA 17-7
280 251 200.5 39.5 24
DDC 15-4
DDE 15-4
24
SMART Digital
6
6. Technical data
Technical data
DDA
DDA 7.5-16 12-10 17-7 30-4
Turndown ratio (setting range) [1:X] 3000 1000 1000 1000
[l/h] 7.5 12.0 17.0 30.0
Max. dosing capacity
[gph] 2.0 3.1 4.5 8.0
[l/h] 3.75 6.00 8.50 15.00
Max. dosing capacity with SlowMode 50 %
[gph] 1.00 1.55 2.25 4.00
[l/h] 1.88 3.00 4.25 7.50
Max. dosing capacity with SlowMode 25 %
[gph] 0.50 0.78 1.13 2.00
[l/h] 0.0025 0.0120 0.0170 0.0300
Min. dosing capacity
[gph] 0.0007 0.0031 0.0045 0.0080
[bar] 16 10 7 4
Max. operating pressure
[psi] 230 150 100 60
Max. stroke frequency 1) [strokes/min] 190 155 205 180
Stroke volume [ml] 0.74 1.45 1.55 3.10
1) The maximum stroke frequency varies depending on calibration Max. pressure for PVC version: 10 bar
2) Data is based on measurements with water
3) Maximum suction lift: 1 m, dosing capacity reduced (approx. 30 %)
4) Length of suction line: 1.5 m, length of discharge line: 10 m (at max. viscosity)
5) With E-box
25
SMART Digital
6
DDC
Technical data
26
SMART Digital
6
DDE
Technical data
DDE 6-10 15-4
Turndown ratio (setting range) [1:X] 1000 1000
[l/h] 6.0 15.0
Max. dosing capacity
[gph] 1.5 4.0
[l/h] 0.0060 0.0150
Min. dosing capacity
[gph] 0.0015 0.0040
[bar] 10 4
Max. pressure
[psi] 150 60
Max. stroke frequency [strokes/min] 140 180
Stroke volume [ml] 0.81 1.58
Accuracy of repeatability [%] 5
1) [m] 6
Mechanical data Max. suction lift during operation
Max. suction lift when priming with wet valves 1) [m] 2 3
Min. pressure difference between suction and discharge side [bar] 1
Max. inlet pressure, suction side [bar] 2
Max. viscosity with spring-loaded valves 2) [mPas] (= cP) 600 500
Max. viscosity without spring-loaded valves 2) [mPas] (= cP) 50 50
Min. internal hose/pipe diameter suction/discharge side 1), 3) [mm] 4 6
Min. internal hose/pipe diameter suction/discharge side (HV) 3) [mm] 9
Min./Max. liquid temperature [C] -10/45
Min./Max. ambient temperature [C] 0/45
Voltage [V] 100-240 V, 50/60 Hz
Length of mains cable [m] 1.5
Max. inrush current for 2 ms at 100 V [A] 8
Electrical data Max. inrush current for 2 ms at 230 V [A] 25
Max. power consumption P1 [W] 19
Enclosure class IP65, Nema 4X
Electrical safety class II
Max. load low-level / empty tank / pulse / external stop input 12 V, 5 mA
Min. pulse length [ms] 5
Signal input
Max. pulse frequency [Hz] 100
Max. resistance in level/pulse circuit [] 1000
Max. ohmic load on relay output [A] 0.5
Signal output
Max. voltage on relay output [V] 30 VDC/30 VAC
Weight (PVC, PP, PVDF) [kg] 2.4 2.4
Weight/size Weight (stainless steel) [kg] 3.2 3.2
Diaphragm diameter [mm] 44 50
Sound pressure Max. sound pressure level [dB(A)] 60
27
SMART Digital
7
7. Pump selection
Pump selection
* Installation set includes: 2 pump connections, foot valve, injection unit, 6 m PE discharge hose, 2 m PVC suction hose, 2 m PVC deaeration hose
(4/6 mm)
** Also available in FC- and FCM-control version
*** PVC dosing heads only up to 10 bar
28
SMART Digital
7
DDC, standard range
Pump selection
Power supply: 1 x 100-240 V, 50/60 Hz (switch mode)
Mains plug: EU
Valves: Standard
Connection set: Hose, 4/6 mm, 6/9 mm, 6/12 mm, 9/12 mm (PVC, PP, PVDF)
Threaded, Rp 1/4", female (SS)
* Installation set includes: 2 pump connections, foot valve, injection unit, 6 m PE discharge hose, 2 m PVC suction hose, 2 m PVC deaeration hose
(4/6 mm)
** Also available in AR-control version
29
SMART Digital
7
DDE, standard range
Pump selection
* Installation set includes: 2 pump connections, foot valve, injection unit, 6 m PE discharge hose, 2 m PVC suction hose, 2 m PVC deaeration hose
(4/6 mm)
** Also available in P- and PR-control version
30
SMART Digital
7
DDA, DDC, DDE, non-standard range
Pump selection
Key to the three following tables:
Maximum flow - pressure [l/h] - [bar]
B: Basic (DDE)
P: B with pulse mode (DDE)
PR: P with relay output (DDE)
Control variant A: Standard (DDC)
AR: A with alarm relay and analog input (DDA, DDC)
FC: AR with FlowControl (DDA)
FCM: FC with flow measurement (DDA)
Dosing head
PP: PP
PVC: PVC (PVC dosing heads only up to 10 bar)
PV: PVDF
SS: Stainless steel 1.4401
Gaskets
Materials
E: EPDM
V: FKM
T: PTFE
Valve balls
C: Ceramic
SS: Stainless steel 1.4401
F: Front-mounted (change to left and right possible)
Control cube position
X: No control cube (DDE)
Supply voltage 3: 1 x 100-240 V, 50/60 Hz
1: Standard
Valve type
2: Spring-loaded (HV version)
Suction / discharge connection
U2U2: Hose, 4/6 mm, 6/9 mm, 6/12 mm, 9/12 mm
U7U7: Hose, 0.17" x 1/4", 1/4" x 3/8", 3/8" x 1/2"
AA: Threaded, Rp 1/4", female (SS)
VV: Threaded, NPT 1/4", female (SS)
Connection / Installation set XX: Without connection
Installation set*
I001: 4/6 mm (up to 7.5 l/h, 13 bar)
I002: 9/12 mm (up to 60 l/h, 9 bar)
I003: 0.17" x 1/4" (up to 7.5 l/h, 13 bar)
I004: 3/8" x 1/2" (up to 60 l/h, 10 bar)
F: EU
B: USA, Canada
G: UK
I: Australia, New Zealand
Mains plug
E: Switzerland
J: Japan
L: Argentina
X: No plug
Design G: Grundfos
* Installation set includes 2 pump connections, foot valve, injection unit, 6 m PE discharge hose, 2 m PVC suction hose, 2 m PVC deaeration hose
(4/6 mm)
31
SMART Digital
7
DDA
Pump selection
DDC
DDE
32
SMART Digital
8
Example:
P S
SMART Digital dosing pump
Pump connection kits and inlay kits see page 47 Dosing tanks see page 50
33
SMART Digital
8
Installation kits for dosing pumps
Accessories for small dosing pumps
Technical data
34
SMART Digital
8
Cables and plugs
Technical data
Socket Application Pins Plug type Cable length [m] Product number
2 96609014
Analog pulse Straight 5 96609016
Input 4
External stop No cable 96698715
Angled 2 96693246
Low level
Input 4 Straight No cable 96698715
Empty tank
2 96632921
Straight 5 96632922
Output Analog 5
No cable 96609031
Angled 2 96699697
2 96609017
Relay 1 Straight 5 96609019
Output 4
Relay 2 No cable 96696198
Angled 2 96698716
35
SMART Digital
8
E-box 150 Profibus (for DDA)
Accessories for small dosing pumps
E-box 150: it is simply placed between the pump and
the mounting plate (DDA software version V2.10 or
higher required). The E-box 150 has a connecting
cable to plug into the pump directly.
Technical data
Supply voltage 30 VDC, 10 % (via M 12 plug of DDA)
Max. power consumption 5W
Cable length 160 mm
Max. relative humidity 96 %
Pollution degree 2
E-box data
IP65 according to IEC 60529
Enclosure class
NEMA 4X
Electrical safety class 3
Min. / max. ambient temperature 0/45 C
Approvals CE, CB, CSA-US, GOST, C-Tick
Data protocol GENIbus
GENIbus connection GENIbus connection type Three-wire RS-485
Transmission speed 9.6 kbits/s
Data protocol Profibus DP
Profibus implementation class DP-V0
Profibus connection type Two-wire RS-485 (lines: A, B)
Screened, double-twisted pair
Recommended cable type conductor cross-section: 0.25 - 1 mm2
Profibus specifications AWG: 24-18
100 m at 12000 kbits/s
Maximum cable length
1200 m at 9.6 kbits/s
Slave address (set in DDA display) 1-126
Line termination (set via DIP switches) On/off
Supported data rates 9.6 kbits/s to 12000 kbits/s
36
SMART Digital
8
Hoses
Technical data
Size
Max. pressure at 20 C
Max. flow rate [l/h]* (internal / outside diameter) Material Length [m] Product number
[bar]
[mm]
3 91835676
PE 13 10 91836504
50 91835680
3 96701733
7.5 4/6 PVC 0.5 10 96702133
50 96727418
3 95730337
ETFE 20 10 95730338
50 95730339
3 95730888
17 5/8 PE 13 10 96727393
50 95730889
3 96727409
PE 12 10 96727412
50 96727415
3 95730334
6/9 PVC 0.5 10 95730335
50 95730336
30
3 95730340
ETFE 20 10 95730341
50 95730342
3 96693751
6/12 PVC, textile-reinforced 23 10 96653571
50 91835686
3 96727395
PE 9 10 96705657
50 96727398
3 96727434
60 9/12 PVC 0.5 10 95730890
50 95724702
3 95730343
ETFE 13 10 95730344
50 95730345
37
SMART Digital
8
Foot valves
Accessories for small dosing pumps
*
*
Technical data
38
SMART Digital
8
Suction lances Dimensions
*
suction hose. They are available either without level
indication or with low-level and empty-tank indication.
Their immersion depth is adjustable.
Suction lances include:
Strainer (mesh size approx. 0.8 mm)
Non-return valve
Hose connection set: 4/6 mm, 6/9 mm, 6/12 mm and
9/12 mm
Adjustable tank connection with holes for e.g. relief
line. *
Suction lances with low-level and empty-tank
indication include additionally:
Reed-switch unit with 2 floaters
/
5 metres of cable with PE jacket
M 12 plug to connect DDA, DDC, DDE or DDI
dosing pump.
indication is factory-set to NO. The switch mode can
be set to NC by turning the floaters upside down.
Electrical data of the level indication:
Fig. 33 Suction lance, dimensions
Max. voltage: 48 V
Max. current: 0.5 A Dimensions / Selection
Max. load: 10 VA.
Recommended
For dosing tank type Tank volume [l] immersion depth (L)
[mm]
40 400
60 500
100 690
Grundfos cylindrical tank
200 690
(see page 51)
300 980
500 1100
1000 1200
Grundfos square tank
TM04 8458 0312
100 690
(see page 50)*
120 820
L-ring drum*
220 980
Steel drum* 216 980
12, 33 (large cap) 400
Fig. 32 Suction lance Standard jerricans
25, 30, 33 500
according to EN 12712*
60 690
IBC* all sizes 1200
39
SMART Digital
8
Technical data
Accessories for small dosing pumps
40
SMART Digital
8
Accessories for suction lances and foot valves with level indication
Product
Adaptor type For container type Remark
number
TM04 8470 0512
counter nut for tanks without threaded opening, e.g. 100-litre square tank or
PVC, grey 98071170
1000-litre cylindrical tank
jerricans with small opening (approx. 36), according to EN 12713 PE, green 98071173
jerricans with medium-sized opening (approx. 45), according to EN 12713 PE, yellow 98071174
jerricans with large opening (approx. 57), according to EN 12713 PE, brown 98071175
US containers with bung hole of 63 mm (ASTM International) PE, white 98071176
IBC (Intermediate Bulk Container) with opening of 150 mm, S 160 x 7 PE, black 98071177
41
SMART Digital
8
Injection units
Accessories for small dosing pumps
G 1/2
L2 L1
L2 L1
Fig. 34 Standard injection unit, PP, PVC, PVDF version Fig. 35 Standard injection unit, stainless-steel version
Technical data
Technical data
42
SMART Digital
8
Injection units with ball valve Dimensions
G 1/2
valve is placed between the injection pipe and the
spring-loaded non-return valve. Thus, the dosing line
Technical data
G 1/2
of the injection pipe is required. The construction
allows the withdrawal of the injection unit from the
process line and the cleaning of it, without stopping the
water flow. The injection point can be closed with the
Technical data
Technical data
43
SMART Digital
8
Multi-function valves, pressure relief valves, pressure loading valves
Accessories for small dosing pumps
Multi-function valves
A multi-function valve is mounted directly on the pump Dimensions
discharge side. The top connection is for the discharge
line, the side connection leads the relief liquid back
into the tank. 0
45
6
Loading pressure, adjustable from 1 to 4 bar, is
92
factory-set to 3 bar.
47
Technical data
44
SMART Digital
8
Pressure relief valves Dimensions
78
(-)
tank.
Relief pressure, adjustable from 5 to 10 bar, is
96(40)
68(68)
factory-set to 10 bar, or
Relief pressure, adjustable from 7 to 16 bar, is
Technical data
(stainless steel).
82 (82)
Technical data
Material
Max. flow rate [l/h] Product number
Diaphragm Housing and connections Gasket
PP FKM / EPDM 95730741
FKM / EPDM 95730742
PVC
PTFE 95730743
60 PTFE
FKM / EPDM 95730744
PVDF
PTFE 95730745
Stainless steel No gaskets 95730751
45
SMART Digital
8
Pressure valves Dimensions
Accessories for small dosing pumps
87
Loading pressure, 3 bar, is not adjustable.
Maximum system pressure: 16 bar.
Spring material: Alloy C-4 (NiMo16CrTi, material
number 2.4610).
G 5/8
Technical data
Material
Max. flow rate [l/h] Product number
Ball Housing Gaskets
FKM 95730325
PP
EPDM 95730326
FKM 95730327
PVC EPDM 95730328
Ceramic
60 PTFE 95730329
FKM 95730330
PVDF EPDM 95730331
PTFE 95730332
Stainless steel Stainless steel PTFE 95730333
46
SMART Digital
8
Pump connection kits and inlay kits
Technical data
Product number
Connection type Size Material
Connection kit Inlay kit
PP 97691902 -
4/6 mm, 6/9 mm, 6/12 mm, 9/12 mm PVC 97691903 -
PVDF 97691904 -
Hose (cone and ring)
PP 97691905 -
0.17" x 1/4", 1/4" x 3/8", 3/8" x 1/2" PVC 97691906 -
PVDF 97691907 -
PP 97702474 95730984
4/6 mm, or 0.17" x 1/4" PVC 97702485 95730720
PVDF 97702495 95730729
PP 98153922 98153977
4/9 mm PVC 98153944 98154006
PVDF 98153949 98154029
PP 97702475 95730711
5/8 mm PVC 97702486 95730721
PVDF 97702496 95730730
PP 97702476 95730712
6/8 mm PVC 97702487 95730722
PVDF 97702497 95730731
PP 97702477 95730713
Hose (cone and ring) 6/9 mm PVC 97702488 95730723
PVDF 97702498 95730732
PP 97702478 95730714
6/12 mm PVC 97702489 95730724
PVDF 97702499 95730733
PP 97702479 95730715
9/12 mm PVC 97702490 95730725
PVDF 97702500 95730734
PP 97702482 95730718
1/4" x 3/8 PVC 97702492 95730727
PVDF 97702503 95730737
PP 97702483 95730719
3/8" x 1/2" PVC 97702493 95730728
PVDF 97702504 95730738
PP 97702481 95730717
Hose (cutting ring type) 1/8" x 1/4"
PVDF 97702502 95730736
PP 97702480 95730716
Pipe welding External diameter 16 mm
PVDF 97702501 95730735
Pipe cementing Internal diameter 12 mm PVC 97702491 95730726
PP 97702484 -
PVC 97702494 -
Pipe, threaded, male 1/2" NPT
PVDF 97702505 -
Stainless steel 97702508 -
Rp 1/4" Stainless steel 97702472 95730739
Pipe, threaded, female
1/4" NPT Stainless steel 97702473 95730740
4/6 mm Stainless steel 97702506 -
Pipe (cutting ring type)
8/10 mm Stainless steel 97702507 -
47
SMART Digital
8
Adaptors
Accessories for small dosing pumps
PVC
G 5/8 G 3/8 PTFE 95730414
FKM / EPDM 95730415
PVDF
PTFE 95730416
PP FKM / EPDM 95730417
FKM / EPDM 95730418
TM04 8298 0411
PVC
G 5/8 G 3/4 PTFE 95730419
FKM / EPDM 95730420
PVDF
PTFE 95730421
PP FKM / EPDM 95730422
TM04 8299 0411
PVC
G 5/8 M 20 x 1.5 PTFE 95730429
FKM / EPDM 95730430
PVDF
PTFE 95730431
PTFE 98154054
PVC 95730437
TM04 8306 0411
PVDF 95730439
48
SMART Digital
8
Hose-to-hose and hose-to-pipe adaptors
Connections Material
Type Description Housing and Product number
Side 1 Side 2 Gaskets
connections
PP FKM / EPDM 95730367
FKM / EPDM 95730368
For hoses 4/6 mm, 6/9 mm, 6/12 mm, PVC
PTFE 95730369
9/12 mm
FKM / EPDM 95730370
PVDF
PTFE 95730371
Valve housing with two
PP FKM / EPDM 95730356
male threads G 5/8
FKM / EPDM 95730357
TM04 8302 0411
PVC
Without PTFE 95730358
FKM / EPDM 95730359
PVDF
PTFE 95730360
Without Threaded Rp 1/4 Stainless steel PTFE 95730361
For hoses
FKM / EPDM 95730378
4/6 mm,
TM04 8360 0711
T-pieces
Technical data
Connections Material
Type Description Housing and Product number
Bottom Top Side Gaskets
connections
PP FKM / EPDM 95730387
FKM / EPDM 95730388
For hoses 4/6 mm, 6/9 mm, 6/12 mm, PVC
PTFE 95730389
9/12 mm
FKM / EPDM 95730390
PVDF
Three male PTFE 95730391
threads G 5/8 PP FKM / EPDM 95730346
TM04 8304 0411
connection with
union nut FKM / EPDM 95730352
PVC
Without PTFE 95730353
FKM / EPDM 95730354
PVDF
PTFE 95730355
49
SMART Digital
8
Dosing tanks
Accessories for small dosing pumps
670
Weight: 15 kg
540
Wall thickness: 4 mm
Liquid temperature: -20 C to +45 C.
SMART Digital pumps can be fitted directly on the
mounting platform by means of brass inserts moulded
into the platform. For other pumps, please use a
console. M5
98
counter nut for fixing (see page 41).
500
98
98
Order data
TM04 8307 0411
50
SMART Digital
8
Cylindrical tanks
Technical data
Dimensions
160
420
350
Rp 3/4"
45
420
160
51
SMART Digital
8
Accessories for small dosing pumps
O
O
O
O
*
*
0[
0[
0[
0[
0[
0[
TM04 8465 0412
Fig. 50 Cylindrical tank, 60 and 100 litres Fig. 52 Cylindrical tank, 500 litres
160
O
O
O
O
*
1260
1150
0[
Rp 3/4"
50
1080
0[
0[
*
Fig. 51 Cylindrical tank, 200 and 300 litres Fig. 53 Cylindrical tank, 1000 litres
52
SMART Digital
8
Collecting tray
For tank size [l] Volume [l] Dimensions (diameter x height) [mm] Product number
60 80 500 x 545 96726831
100 120 500 x 700 96726832
200 210 770 x 595 98150059
300 400 770 x 960 96726834
500 500 860 x 980 95701272
1000 1000 1150 x 1080 96726836
270
140
283
120
70
Technical data
53
SMART Digital
8
Water meter
Accessories for small dosing pumps
Dimensions
Threaded connection
Qn 1.5 G 3/4 G 1/2 165 245
Qn 2.5 G1 G 3/4 190 288
Qn 15 G 2.5 G2 300 438
Flanged connection
Qn 40 DN 80 225 -
Qn 60 DN 100 250 -
Qn 150 DN 150 300 -
54
SMART Digital
9
9. Pumped liquids
Pumped liquids
The resistance table below is intended as a general The data shown are based on information from various
guide for material resistance (at room temperature), sources available, but many factors (purity,
and does not replace testing of the chemicals and temperature, abrasive particles, etc.) may affect the
pump materials under specific working conditions. chemical resistance of a given material.
Note: Some of the liquids in this table may be toxic,
corrosive or hazardous. Please be careful when
handling these liquids.
Material
Pumped liquid (20 C)
(Accessories)
Dosing head Gasket Ball
SS 1.4401
Ceramic
Chemical Concentration
EPDM
Description
PVDF
PTFE
formula %
FKM
PVC
PP
PE
25
Acetic acid CH3COOH 60
85
Aluminium chloride AlCl3 40
Aluminium sulphate Al 2(SO4)3 60
Ammonia, aqueous NH4OH 28
Calcium hydroxide 7 Ca(OH)2
Calcium hypochlorite Ca(OCl)2 20
10
Chromic acid H2CrO4 30
50
Copper sulphate CuSO4 30
Ferric chloride 3 FeCl3 60
Ferric sulphate 3 Fe 2(SO4)3 60
Ferrous chloride FeCl2 40
Ferrous sulphate FeSO 4 50
Fluosilicic acid H2SiF6 40
< 25
Hydrochloric acid HCl
25-37
Hydrogen peroxide H 2O 2 30
30
Nitric acid HNO3 40
70
Peracetic acid CH3COOOH 5-15
Potassium hydroxide KOH 50
Potassium permanganate KMnO 4 10
Sodium chlorate NaClO3 30
Sodium chloride NaCl 30
Sodium chlorite NaClO2 20
30
Sodium hydroxide NaOH
50
Sodium hypochlorite NaOCl 12-15
Sodium sulphide Na 2S 30
Sodium sulphite Na2SO3 20
Sodium thiosulfate Na2S2O3 10
Sulphurous acid H 2SO3 6
< 80
Sulphuric acid 4 H2SO4 80-96
98
Resistant 3 Risk of crystallisation.
Limited resistance 4 Reacts violently with water and generates much heat.
(Pump should be absolutely dry before dosing sulphuric acid.)
Not resistant 7 Once the pump is stopped, calcium hydroxide will sediment rapidly.
For further information, see "Pumped liquid guide".
55
SMART Digital
10
WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185 000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
Catalogue
Literature
Service
Sizing
Replacement
CAD drawings.
Catalogue
Literature
Service
56
SMART Digital
10
Replacement
CAD drawings
2-dimensional drawings
.dxf, wireframe drawings
.dwg, wireframe drawings.
3-dimensional drawings
.dwg, wireframe drawings (without surfaces)
.stp, solid drawings (with surfaces)
.eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
informtion on more than 185,000 Grundfos products in
more than 22 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once
a year.
57
SMART Digital
10
GO CAPS
Further product documentation
58
59
ECM: 1116599
95724709 0713
GRUNDFOS A/S
www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. Copyright Grundfos Holding A/S