Table 1: Dimensions Dimensions in mm / inches
To select the nominal size (DN), please use the flow capacity charts on the following pages
IIB3 IIC
DN a b
c* c*
50 / 2" 100 / 3.94 200 / 7.87 170 / 6.69 185 / 7.28
80 / 3" 150 / 5.91 240 / 9.45 180 / 7.09 195 / 7.68
100 / 4" 200 / 7.87 295 / 11.61 220 / 8.66 235 / 9.25
150 / 6" 300 / 11.81 550 / 21.65 260 / 10.24 270 / 10.63
200 / 8" 300 / 11.81 550 / 21.65 260 / 10.24 270 / 10.63
250 / 10" 400 / 15.75 600 / 23.62 355 / 13.98 365 / 14.37
300 / 12" 400 / 15.75 600 / 23.62 340 / 13.39 350 / 13.78
350 / 14" 600 / 23.62 800 / 31.50 390 / 15.35 400 / 15.75
400 / 16" 600 / 23.62 800 / 31.50 380 / 14.96 390 / 15.35
500 / 20" 700 / 27.56 1000 / 39.37 400 / 15.75 410 / 16.14
600 / 24" 800 / 31.50 1200 / 47.24 475 / 18.70 485 / 19.09
700 / 28" 1000 / 39.37 1400 / 55.12 505 / 19.88 515 / 20.28
800 / 32" 1200 / 47.24 1600 / 62.99 550 / 21.65 560 / 22.05
* c are reference values. Exact measures depend on the flange connection.
KA / 2 / 0414 / GB 69
Deflagration Flame Arrester, End-of-Line
Flow Capacity Charts
PROTEGO LH/AD
FM Approvals
pp
Specifi
cification Tested
.
flow rate V (m/h) 1608-L
LH/AD-IIC
pressure drop p (mbar)
.
flow rate V (m/h) 1690-L
The flow capacity charts have been determined with a calibrated and TV certified flow capacity test rig.
.
Volume flow V in (m/h) and CFH refer to the standard reference conditions of air ISO 6358 (20C, 1bar).
Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals.
All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de
70 KA / 2 / 0414 / GB