2-Way Triple L-Band Active Splitter: With LNB Powering & Internal 10Mhz Source

This document provides specifications for a 2-way triple L-band active splitter with LNB powering and an internal 10MHz source. The splitter shelf contains 3 two-way splitter modules in a 2U chassis with dual redundant power supplies. Key features include LNB power switching, 10MHz source stability better than 1ppm, and alarm contacts for power supply failure monitoring.

Uploaded by

raymund12345
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views

2-Way Triple L-Band Active Splitter: With LNB Powering & Internal 10Mhz Source

This document provides specifications for a 2-way triple L-band active splitter with LNB powering and an internal 10MHz source. The splitter shelf contains 3 two-way splitter modules in a 2U chassis with dual redundant power supplies. Key features include LNB power switching, 10MHz source stability better than 1ppm, and alarm contacts for power supply failure monitoring.

Uploaded by

raymund12345
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Model Number:

D0102T2ULA-22276-XXXX

Typical applications:

2-Way Triple L-band Satellite operators, VSAT,


teleports, and broadcasters
High resilience RF distribution

Active Splitter where optimum satellite signal


quality is required
Teleports with limited rack
With LNB Powering & internal space

10MHz Source
This L-band splitter shelf contains 3 of ETLs 2-way active splitter modules and is housed in a 2U high shelf. The unit
has dual redundant power supplies and can be used to provide LNB powering (the LNB bias for each RF input port can
be switched on and off from the rear panel). The unit has a dry contact alarm for PSU failure.

850 - 2150 MHz


operating frequency Local monitoring Front
10MHz Internal 10MHz Source range. Panel LEDs for monitoring
PSUs

Compact 2U 18V LNB Powering Resilience


chassis housing Switchable LNB powering from dual
3 2-way splitters (on/off) selectable for each redundant
splitter module power supplies

V1.1 E&OE
Model Number:
D0102T2ULA-22276-XXXX
2-way Triple L-band Active Splitter With LNB
Powering & internal 10MHz Source
Technical specifications and operating parameters
RF Parameters
Capacity 2- way (Triple)
Frequency Range 850-2150 MHz (L-band)
Connector & Impedance 50 SMA 50 BNC 50 N-type 75 BNC 75 F-type
Gain 1 1.0 dB 1 1.0 dB 1 1.0 dB 1 1.0 dB 1 1.0 dB
850-2150MHz 1.0 dB 1.0 dB 1.0 dB 1.2 dB 1.25 dB
Flatness
Any 36MHz 0.35 dB 0.50 dB 0.35 dB 0.50 dB 0.50 dB

Input Return Typical 15 dB 15 dB 15 dB 12 dB 12 dB


Loss Minimum 10 dB 10 dB 10 dB 8 dB 8 dB

Output Return Typical 18 dB 18 dB 18 dB 15 dB 12 dB


Loss Minimum 12 dB 12 dB 12 dB 8 dB 8 dB
1dB Compression 0 dBm (Typically 5 dBm) output power
Noise Figure <10 dB (Typically 7 dB)
LNB Power 18V nominal, 500mA max per channel, switchable on/off power
Alarms Dry contact alarm
AC Power 85-264 VAC (50/60Hz)
Input RF power +18dBm Absolute Maximum
PSU Dual Redundant (Diode OR)
Display Front Panel LEDs for monitoring PSUs
Operating temperature 0 to 45C (Indoor use only)

Storage temperature -20C to +75C

Humidity 85% non-condensing


Dimensions 2U high x 350mm deep x 19 wide
Weight 8 kg
Colour White 00-E-55 semi-gloss

10MHz Source
Type Sine Wave
Output Frequency 10MHz 10Hz, 1ppm
Level 0 2 dBm, fundamental
Harmonic Rejection >40dBc (50dBc nominal)
Per day < 2 x 10-9
Ageing
Per year < 5 x 10-7
Frequency Stability over temperature < 3 x 10-8
Warm up time < 2 min at 25C to < 1 x 10-7
1Hz < -85
10Hz < -115
Phase Noise 100Hz < -140
1KHz < -150
10KHz < -155
Preliminary Specifications

ETL SYSTEMS LIMITED TELEPHONE FACSIMILE


Coldwell Radio Station +44 (0)1981 259020 +44 (0)1981 259021
Madley
Hereford EMAIL WEB
England HR2 9NE [email protected] www.etlsystems.com