TCS SERIES (Digital Counting Scale)
TCS SERIES (Digital Counting Scale)
TCS Series
DIGITAL COUNTING SCALE User Manual
Revision 1.1 November 13, 2007
Contents
I. Introduction ................................................................................................. 1
X . Limited Warranty.................................................................................... 16
XI. Troubleshooting...................................................................................... 17
I. Introduction
Transcell Technology, Inc., founded in 1981, is an ISO 9001 registered enterprise
group which manufactures precision weighing instruments and sensors. Our major
products include load cells, digital indicators, scales, and automated control
equipment. Our products have been placed in service throughout the world including
North and South America, Europe, South and East Asia and Australia. Through our
dedication and expertise in high-quality manufacturing, we will continue to bring our
customers products and services well beyond their expectations.
With its high precision load cell, proprietary software (developed by our American
R&D) and its Texas Instruments MPU, the TCS series is characterized by its high
resolution, fast but steady weighing performance and its precision counting. As an
ideal weighing and counting tool, the TCS series is designed for industrial, laboratory
and classroom applications.
In order to help you use our instrument properly, thus prolonging its life, please read
the entire user manual carefully and be sure to keep it in a handy place.
1
II. Specifications
1. Load cell: FATS Series
2. Product Matrix:
3. Integrated functions:
Counting
Accumulator
Tare and preset tare function
4. Rated voltage
AC 120V1060Hz1Hz
DC 6V/4Ah rechargeable battery
5. Power consumption0.24W
6. Operating temperature range0 to 4032F to 104F
7. Humidity
Storage70%RH non-condensing
Operating90%RH non-condensing
8. Low battery warning
If a solid appears on the upper left hand corner the battery voltage is too
low and it needs to be recharged. When the back lighting shuts off and the scale
displays LO BAT, it means that the battery has been exhausted to its limit and
will be damaged if used any longer. When this occurs, you must switch off the
scale and then recharge the battery immediately.
9. Charging
The battery can be recharged by plugging the AC cord into a 120 VAC power
outlet. The battery will be fully charged within 8-10 hours. The scale can be used for
about 100 hours when the battery is fully charged.
2
III. Safety Tips
Routine maintenance
Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions should not be used;
especially on the display window.
The outside of the product may be wiped down with a clean cloth, moistened with water containing a
small amount of soap.
1. Ensure that the scale is placed securely on a flat and level surface.
2. Scale is intended for indoor use only.
3. Avoid installing the scale in areas of direct sunlight and high humidity. Also avoid
drafts, vibrations and dusty conditions.
4. To extend the life of your digital scale, do not drop items to be weighed onto the
tray or overload the scale beyond its rated capacity. Shock-loading and
overloading may damage the load cell and void the warranty.
5. Please charge the battery before use. If the scale is not to be used often, then
please charge the battery once every three months.
6. A transparent cover is provided and is capable of preventing dust and indirect
water spray from penetrating the scale. To install, remove the tray and place the
cover over the scale housing. Please make sure that the cover does not touch the
tray as this likely will influence the weighing results.
3
IV. Preparing the scale for use
1. Prior to using the scale, the transport protection screw located on the bottom of
the scale must be removed. Refer to the following figure for location.
3. Place the tray on the scale and adjust the four feet until the scale does not rock
back and forth on the table. Be sure also that the leveling bubble is in the center.
4. Recharge the battery by plugging the scale into a 120 VAC outlet. Continue
5. Make sure that nothing is on the tray when the scale is switched ON.
6. When first switched ON, the scale will enter a self-check mode. During this mode
the display will count down from 999999 to 000000. Once complete, the scale is
ready for use.
4
V. Parts Illustration
5
VI. Display Information
Annunciators ( )
1. TARE: indicates the weight of the goods without packaging;
2. ZERO: indicates that the scale is at a zero condition;
3. If this symbol does not appear, it means that the battery is fully charged. If
this symbol appears, it means that the battery voltage is too low and it needs to be
recharged. When the back lighting shuts off and the scale displays LO BAT, it
means that the battery has been exhausted to its limit and will be damaged if used
any longer. When this occurs, you must switch off the scale and then recharge the
battery immediately;
6
Annunciators ( ) / Continued
Remarks
minimum sample weight must be 20d
minimum piece weight must be 0.2d (d= one scale division)
7
VII. Keypad Information
1. TRGTUsed to set a target quantity prior to counting. Key-in the target quantity and
then press TRGT. When the number of items placed on the tray exceeds the target
quantity, the scale sounds an alarm and flashes ;
2. SMPLUsed to sample parts for counting. Key-in the quantity of items on the tray
and then press SMPL;
3. UNIT WTUsed to key-in a known piece weight for counting. Key-in the piece
weight and then press UNIT WT;
4. UWT PSTUsed to recall or program a preset unit weight for counting;
5. M+Used to accumulate multiple weighments or pieces.
6. MCUsed to clear the accumulator;
7. CEReturns scale to weighing mode if in piece counting mode. Also can be used to
clear the piece weight, the accumulator or last number entered;
8. ZERO/UNIT Press this key once to zero the scale when nothing is on the tray.
Press and hold this key to temporarily switch units from kg to lb or from lb to kg;
9. TAREPressing this key subtracts the weight of the package on the tray. Key-in
the tare weight and then press TARE if the weight is known;
10. 09Used to enter numeric data as needed;
11. /PRINTUsed to insert Decimal Point. Also acts as a Print key;
8
VIII. Main Functions
Counting
Stable
Weight of the item on the tray
Stable
Weight of the item on the tray Quantity of the sample
3The scale calculates the piece weight
Stable
4The piece weight is now set; you can now remove the sample and continue counting
Stable
Weight of the item on the tray Single weight Quantity of the sample
Zero Stable
Single weight of the item
2Press UNIT WT key
Zero Stable
Zero Stable
Single weight of the item
9
Accumulator (M+)
Stable
Weight of the item on the tray Single weight of the item Quantity of the item
3After accumulation
M+
Stable
Weight of the item on the tray Single weight of the item Quantity of the item
If the accumulator quantity is over 99999, the display will scroll. For example, if the accumulator quantity
is 100005, it will display as follows:
Press the MC key to clear the accumulator value and the symbol .
10
Weighment Accumulator
1 Place the item on the tray when the scale is at zero
Stable
Weight of the item on the tray
3After stable
Stable
Weight of the item on the tray
If the total weight is over 99999, the display will scroll, e.g., if the accumulator value is 10000.5g, the
display is as follows:
11
Clearing the accumulator value
Stable
Stable
Stable
4Press UWT PST key to save the piece weight into the preset location you have selected above
Stable
Stable
Stable
Stable
12
3Press UWT PST key to recall the preset piece weight
Stable
Target Setup
Program the target value when scale is in counting mode. An alarm sounds when the
number of pieces on the try exceeds the programmed target value. In addition, the
display flashes .
Stable
Stable
Stable
Stable
13
The weight of the container is known
1When the scale is at zero, input the weight of the container using the 0-9keys.
Stable
Stable
Zero
Occasionally, there may be zero drift during operation. Press the
ZERO/UNIT key to make the scale return to zero.
Zero range = 100% of weighing capacity
Weighing after zero= the rated capacity of the scale is not extended, e.g. On a 6 kg scale,
if a 2 kg weight is zeroed off, the weighing range of the scale is now 4 kg.
Backlighting setup
Press and hold the TARGET key for 3 seconds. The display will show AUTO, ON or
OFF. Press the 4 or 6 key to select the mode you want and then press the M+ key
to save.
AUTO = backlighting will come on automatically during operation and will shut off after
approximately 10 seconds of inactivity.
ON = backlighting is ON all of the time. (NOTE: this setting will diminish the batterys charge)
OFF = backlighting is OFF all of the time. (NOTE: this setting will help save the batterys
charge)
14
IX . Serial Port Information
The TCS is plug and play compatible with the Transcell MP-20 printer. If you have a different printer, use
the following information to make the proper connections:
Hardware
The TCS serial port is realized in an RS-232C compatible male DSUB9 connector. See illustrations below
for pin outs:
Operation
1. Whenever the /PRINT key is pressed the scale prints a ticket as shown in the following
illustration.
GROSS 25.00 lb
TARE 1.48 lb
NET 23.52 lb
2. Whenever the M+ key is pressed and an item is added to the accumulator, the scale prints a one
line summary. Whenever the Memory Recall function is invoked, the scale prints a single total
line. Following is an example of a complete print ticket with 5 weighment lines and 1 total line:
15
X . Limited Warranty
Seller warrants that the TCS Series Digital Counting Scale will conform to written specifications,
drawings, and other descriptions made by the manufacturer, including any modifications thereof. The
Seller warrants the goods against faulty workmanship and defective materials. If any goods fail to conform
to these warranties, Seller will, as its sole and exclusive liability hereunder, repair or replace such goods if
they are returned within the following warranty period:
1) Transcell Technology, Inc. is given prompt written notice upon discovery by Buyer of such
non-conformity, with a detailed explanation of the alleged deficiencies;
2) Such goods are returned to the Seller at the expense of the Buyer;
3) Examination of such goods by Seller discloses that the nonconformity actually exists and was not
caused by accident, misuse, neglect, alteration, improper installation improper or unauthorized repair,
or improper testing, and
4) Such goods have not been modified, altered, or changed by any person other than the Seller or its duly
authorized repair agents.
5) Transcell Technology, Inc. will have a reasonable time to repair or replace such goods.
No terms, conditions, understanding, or agreements purporting to modify the terms of this warranty shall
have any legal effect unless made in writing and signed by a corporate officer of the Seller.
16
XI. Troubleshooting
Fault
No. Cause of fault Solution
Description
17
Contents subject to change without notice.
18