This document provides information on the D5072S-087 Isolating Repeater including its characteristics, technical data, inputs, outputs, performance, safety certification, and ordering information. The isolating repeater accepts a 2-3-4 wire resistance or 2-wire potentiometer sensor up to 400 ohms located in a hazardous area and repeats the resistance signal with isolation to a safe area while providing fault detection capabilities. It is certified for use in hazardous locations and functional safety applications up to SIL3.

Uploaded by

mojinjo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views2 pages

D5072-087 DTS0434

This document provides information on the D5072S-087 Isolating Repeater including its characteristics, technical data, inputs, outputs, performance, safety certification, and ordering information. The isolating repeater accepts a 2-3-4 wire resistance or 2-wire potentiometer sensor up to 400 ohms located in a hazardous area and repeats the resistance signal with isolation to a safe area while providing fault detection capabilities. It is certified for use in hazardous locations and functional safety applications up to SIL3.

Uploaded by

mojinjo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

D5072 Resistance Isolating Repeater,

- 087 DIN-Rail, Model D5072S-087

Characteristics: Technical Data:


General Description: Supply:
The single channel Isolating Repeater D5072S-087 accepts a 2-3-4 wire 24 Vdc nom (18 to 30 Vdc) reverse polarity protected,
resistance/RTD or 2-wire transmitting potentiometer sensor, up to 400 , ripple within voltage limits 5 Vpp, 2 A time lag fuse internally protected.
located in Hazardous Area, and repeats the resistance, with isolation, to Safe Area. Current consumption @ 24 V: 33 mA typical.
Power dissipation: 0.8 W with 24 V supply voltage.
Mounting on standard DIN-Rail, with or without Power Bus , in
Safe Area / Non Hazardous Location or in Zone 2 / Class I, Division 2 or Class I, Isolation (Test Voltage):
Zone 2. I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; Out/Supply 500 V.
Choice between 2, 3 or 4 wires Input is accomplished via dedicated DIP Switch.
Among all possible sensors, typical are: Input:
IEC: Pt50, Pt100 2-3-4 wire RTD/Resistance or 2-wire transmitting Potentiometer.
Integration time: 250 ms for 2-wire sensors; 500 ms for 3,4-wire sensors.
ANSI 0.3916: Pt100 Resolution: 1 m.
DIN43760: Ni100, Ni120 Input range: 0 to 400 .
Measuring RTD current: 0.15 mA.
GOST6651 russian standard: Pt46, Pt50, Pt100 ,Cu50, Cu53, Cu100
Cu9.035 (or Cu10) Burnout Fault:
Output reflects fault condition via highscale (440 ) value forcing.
Fault Detection: Fault condition is also signaled via BUS and red LED on front panel.
D5072S-087 module is able to detect the breakage of any Input sensor line (Burnout). Output:
This situation is signaled via dedicated red LED on front panel, open collector transistor 2-3-4 wires Resistance.
on Fault bus and highscale (440 ) forcing of output resistance. Transfer characteristic: linear.
Response time: 20 ms (10 to 90 % step).
Functional Safety Management Certification: Output range: 0 to 400 .
G.M. International is certified by TUV to conform to IEC61508:2010 Excitation current (Ie): 0.1 to 5 mA.
part 1 clauses 5-6 for safety related systems up to and included SIL3.
Performance:
Ref. Conditions 24 V supply, 23 1 C ambient temperature, 4-wires RTD.
Input:
Calibration and linearity accuracy: 100 m.
Temperature influence: 20 m / C, typical.
Output:
Front Panel and Features: Calibration and linearity accuracy:
< 150 m typical (Excitation Current 1 mA);
< 250 m typical (0.5 mA Excitation Current < 1 mA).
Temperature influence: 10 m / C, typical (Excitation Current 0.5 mA).
5 6 Input from Zone 0 (Zone 20) / Division 1,
3 4 Compatibility:
1 2 installation in Zone 2 / Division 2. CE mark compliant, conforms to Directives:
94/9/EC Atex, 2004/108/CE EMC, 2006/95/EC LVD, 2011/65/EU RoHS.
2 or 3 or 4 wire resistance/RTD or
Environmental conditions:
2 wire transmitting potentiometer Input Signal. Operating: temperature limits 40 to + 70 C, relative humidity 95 %, up to 55 C.
Storage: temperature limits 45 to + 80 C.
Burnout Fault detection.
Safety Description:
Three port isolation, Input/Output/Supply.
EMC Compatibility to EN61000-6-2,
ATEX: II 3(1) G Ex nA [ia Ga] IIC T4 Gc, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
EN61000-6-4, EN61326-1, EN61326-3-1 IECEx: Ex nA [ia Ga] IIC T4 Gc, [Ex ia Da] IIIC, [Ex ia Ma] I,
associated apparatus and non-sparking electrical equipment.
PWR for safety systems. Uo/Voc = 7.2 V, Io/Isc = 23 mA, Po/Po = 40 mW ,
FLT Ui/Vmax = 12.8 V, Ii/Imax = 28.7 mA, Ci = 0 nF, Li = 0 nH at terminals 7-8-9-10.
ATEX, IECEx, INMETRO Certifications. Um = 250 Vrms, -40 C Ta 70 C.
Approvals:
TV Functional Safety Certification. BVS 12 ATEX E 053 X conforms to EN60079-0, EN60079-11, EN60079-15, EN60079-26,
IECEx BVS 12.0050X conforms to IEC60079-0, IEC60079-11, IEC60079-15, IEC60079-26.
Type Approval Certificate DNV and KR for TV Certificate No. C-IS-236198-09, SIL 3 Functional Safety Certificate conforms to
IEC61508:2010 Ed.2, for Management of Functional Safety.
maritime applications. DNV Type Approval Certificate No.A-13625 and KR No.MIL20769-EL002 Certificates for
maritime applications.
Simplified installation using standard DIN-Rail
Mounting:
and plug-in terminal blocks, with or without T35 DIN-Rail according to EN50022, with or without Power Bus.
Weight: 125 g.
Power Bus. Connection: by polarized plug-in disconnect screw terminal blocks to accommodate
D5072
terminations up to 2.5 mm2.
-087 250 Vrms (Um) max. voltage allowed to the Location: installation in Safe Area or Zone 2, Group IIC T4.
Protection class: IP 20.
7 8 instruments associated with the barrier. Dimensions: Width 12.5 mm, Depth 123 mm, Height 120 mm.
9 10

Ordering Information:

Model: D5072S-087 Power Bus and DIN-Rail accessories:


Connector JDFT049
Cover and fix MCHP196
Terminal block male MOR017
Terminal block female MOR022

G.M. International DTS0434-4 Page 1/2 - PRELIMINARY INFORMATION www.gmintsrl.com


Parameters Table: Image:
Safety Description Maximum External Parameters
Group Co/Ca Lo/La Lo/Ro
Cenelec (F) (mH) (H/)
D5072S-087:Terminals 7-8-9-10 IIC 13.5 67 875
Uo/Voc = 7.2 V IIB 240 268 3500
Io/Isc = 23 mA IIA 1000 537 7000
Po/Po = 40 mW I 1000 882 11480
Ui/Vmax = 12.8 V IIIC 240 268 3500
Ii/Imax = 28.7 mA
Ci = 0 nF, Li = 0 nH

Function Diagram:

HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4

MODEL D5072S-087

2 wires 2-3-4 wires 5+


=
Potentiometer RTD / Resistance = Supply 24 Vdc
6-
9 =
10 Ohm 1+
7 2+
=
8
3-
4-

2-3-4 wires

In Out

F - +
Fault and Power Bus

G.M. International DTS0434-4 Page 2/2