Function

A configuration command that modifies the call control parameters related to UTRAN system
messages of a cell. In this command, the following parameters uniquely identify the cell:

Cell Index or Cell Name

Note
None

Parameters
ID Name Description
IDXTYPE Index type Meaning:Index type

Value range:BYNAME(By Name),BYIDX(By


Index)

Explanation:Index Type.

Default value:None
CELLIDX Cell index Meaning:Cell index

Value range:0~2047

Explanation: This parameter indicates the source cell


index. The source cell index must be unique.

Default value:None
CELLNAME Cell name Meaning:Cell name

Value range:1-32 characters

Explanation: This parameter indicates the name of


the source cell. The name of each cell under one
BSC must be unique.

Default value:None
MSCVER MSC Version Meaning:MSC Version indication
indication
Value range:R98_or_below(R98 or
below),R99_or_above(R99 or above)

Explanation: This parameter indicates the protocol


version of the MSC that works with the BSC. The
supported signaling varies with the protocol
versions.

Default value:None
MEASURETYPE Measurement Meaning:Measurement Report Type
Report Type
Value range:EnhMeasReport(Enhanced
Measurement Report),ComMeasReport(Common
Measurement Report)

Explanation: This parameter specifies the type of


measurement report sent by an MS.

The enhanced measurement report is a new downlink


measurement report, reported by the MS.

Compared with the normal measurement report, the


enhanced measurement report has some new
measurement items, such as BER and FER. An MS
can report up to six GSM neighbor cells in a normal
measurement report. Compared with the normal
measurement report, the enhanced measurement
report has more measurement items.

Default value:None
GSMFREQCNUM Serving band Meaning:Serving band reporting
reporting
Value range:0~3

Explanation: If the system information indicates


"MBR", the MS reports the number of neighbor cells
on different frequency bands.

When the MS reports the number of neighbor cells


on the same frequency band with the serving cell, a
maximum of the value of Serving Band Reporting
can be reported.

These neighbor cells must meet the following


requirements:
1. The receive levels of the neighbor cells must be
higher than 900 Reporting Threshold or 1800
Reporting Threshold.

2. The BSIC of a neighbor cell must be valid.

3. The signals of the neighbor cells must be the


strongest among all the neighbor cells on the same
frequency band.

Default value:None
QI Qsearch I Meaning:Qsearch I

Value range:0~15

Explanation: This parameter specifies the level


threshold for cell reselection in idle mode.

In idle mode, if the signal level in the serving cell is


below [0, 7] or above [8, 15], the MS starts to search
for 3G cells.

For example:

If this parameter is set to 5 and if the signal level of


the serving cell is lower than 5, the MS starts to
search for 3G cells.

If this parameter is set to 10 and if the signal level of


the serving cell is higher than 10, the MS starts to
search for 3G cells.

0: -98 dBm

1: -94 dBm

2: -90 dBm

3: -86 dBm

4: -82 dBm

5: -78 dBm
6: -74 dBm

7: (always), that is, the MS keeps searching for 3G


cells

8: -78 dBm

9: -74 dBm

10: -70 dBm

11: -66 dBm

12: -62 dBm

13: -58 dBm

14: -54 dBm

15: infinity(never), that is, the MS does not search


for 3G cells.

Default value:None
QCI Qsearch C Meaning:Qsearch C initial
initial
Value range:Use_Qsearch_I(Use
Qsearch_I),Always(Always)

Explanation: This parameter specifies the threshold


of the signal level for cell reselection in connection
mode before Qsearch C is obtained.

Default value:None
FDDQOFF FDD Q offset Meaning:FDD Q offset

Value range:0~15

Explanation: Only when the average receive level of


a 3G cell is FDD Q Offset greater than that of the
serving cell, the 3G cell becomes a candidate cell.

0: negative infinity(always select a cell if acceptable)


1: -28 dB

2: -24 dB

...

15: 28 dB.

Default value:None
FDDREP FDD REP Meaning:FDD REP QUANT
QUANT
Value range:RSCP(RSCP),EcN0(Ec/N0)

Explanation: This parameter specifies the


measurement report counter of an FDD cell.

Default value:None
FDDFREQCNUM FDD Meaning:FDD MULTIRAT reporting
MULTIRAT
reporting Value range:0~3

Explanation: This parameter specifies the number of


UTRAN FDD cells that should be contained in the
best cell list or in the measurement report.

Default value:None
FDDQMIN FDD Qmin Meaning:FDD Qmin

Value range:0~7

Explanation: This parameter specifies one threshold


of the signal level for 3G cell reselection.

Only when the receive level of a 3G cell is greater


than FDD Qmin, the 3G cell can be one candidate
cell for cell reselection.

0: -20 dB

1: -6 dB

2: -18 dB
3: -8 dB

4: -16 dB

5: -10 dB

6: -14 dB

7: -12 dB.

Default value:None
QP Qsearch P Meaning:Qsearch P

Value range:0~15

Explanation: This parameter specifies one threshold


of the signal level for cell reselection in packet
transfer mode.

In packet transfer mode, if the signal level in the


serving cell is below [0, 7] or above [8, 15], the MS
starts to search for 3G cells.

For example:

If this parameter is set to 5 and if the signal level of


the serving cell is lower than 5, the MS starts to
search for 3G cells.

If this parameter is set to 10 and if the signal level of


the serving cell is higher than 10, the MS starts to
search for 3G cells.

0: -98 dBm

1: -94 dBm

...

6: -74 dBm

7: (always)

8: -78 dBm
9: -74 dBm

...

14: -54 dBm

15: infinity (never).

Default value:None
3GSEARCH 3G Search Meaning:3G Search PRIO
PRIO
Value range:NO(NO),YES(YES)

Explanation: This parameter specifies whether the


MS is allowed to search for a 3G cell when the BSIC
must be decoded.

Default value:None
INVALBSICEN Invalid BSIC Meaning:Invalid BSIC reporting
reporting
Value range:NO(NO),YES(YES)

Explanation: This parameter specifies whether the


EMR can contain the information about a cell with
an invalid BSIC.

Default value:None
SCALEORDER SCALE_OR Meaning:SCALE_ORDER
DER
Value
range:ADD0dB(+0dB),ADD10dB(+10dB),Automati
c(Automatic)

Explanation: This parameter indicates that when the


MS reports the EMR, it adds the value of this
parameter to the received signal level, and then
converts the result into the RXLEV value. For
details, see GSM Rec. 05.08.

If the SCALE_Order reported by the MS is 10 dBm,


level values 0-63 map with -100 dBm to -37 dBm.

If the SCALE_Order reported by the MS is 0 dBm,


level values 0-63 map with -110 dBm to -47 dBm.

If the SCALE_Order reported by the MS is


Automatic, the MS chooses the least SCALE while
ensuring that the MS can report the most strong
level.

Default value:None
QSEARCHC Qsearch C Meaning:Qsearch C

Value range:0~15

Explanation: This parameter specifies the level


threshold for cell reselection in connection mode.

In connection mode, if the signal level in the serving


cell is below [0, 7] or above [8, 15], the MS starts to
search for 3G cells.

For example:

If this parameter is set to 5 and if the signal level of


the serving cell is lower than 5, the MS starts to
search for 3G cells.

If this parameter is set to 10 and if the signal level of


the serving cell is higher than 10, the MS starts to
search for 3G cells.

0: -98 dBm

1: -94 dBm

...

6: -74 dBm

7: (always)

8: -78 dBm

9: -74 dBm

...
14: -54 dBm

15: infinity (never).

Default value:None
CELL900OFF 900 reporting Meaning:900 reporting offset
offset
Value range:0~7

Explanation: This parameter specifies the signal


level offset of a GSM900 cell.

When the priority of a GSM900 cell is sequenced on


the basis of its frequency band, the value of this
parameter should be added to the receive level in the
measurement report.

0: 0 dB

1: 6 dB

...

7: 42 dB.

Default value:None
CELL900THRED 900 reporting Meaning:900 reporting threshold
threshold
Value range:0~7

Explanation: This parameter specifies the threshold


for determining whether the MR about a GSM900
cell is valid.

When the receive level of the GSM900 cell in the


measurement report is greater than the value of this
parameter, the measurement report is valid. After the
measurement report is filtered, the cell joins in the
cell priority rank.

0: 0 dB

1: 6 dB
...

6: 36 dB

7: infinity.

Default value:None
CELL1800OFF 1800 Meaning:1800 reporting offset
reporting
offset Value range:0~7

Explanation: This parameter specifies the signal


level offset of a DCS1800 cell.

When sequencing the priority of a DCS1800 cell


based on its frequency band, the value of this
parameter should be added to the receive level in the
measurement report.

0: 0 dB

1: 6 dB

...

7: 42 dB.

Default value:None
CELL1800THRED 1800 Meaning:1800 reporting threshold
reporting
threshold Value range:0~7

Explanation: This parameter specifies the threshold


for determining whether the MR about a DCS1800
cell is valid.

If the receive level of the 1800 MHz cell in the


measurement report is greater than the value of this
parameter, the measurement report is valid. After the
measurement report is filtered, the cell joins in the
cell priority sequence.

0: 0 dB
1: 6 dB

...

6: 36 dB

7: infinity.

Default value:None
FDDCELLOFF FDD Meaning:FDD reporting offset
reporting
offset Value range:0~7

Explanation: This parameter specifies the signal


level offset of an FDD cell.

When the priority of a 3G cell is sequenced, it is


recommended that the value of this parameter be
added to the receive level of the 3G cell in the
measurement report.

0: 0 dB

1: 6 dB

...

7: 42 dB.

Default value:None
FDDCELLTHRED FDD Meaning:FDD reporting threshold
reporting
threshold Value range:0~7

Explanation: This parameter specifies the threshold


for determining whether the MR about an FDD cell
is valid.

If the receive level of the 3G cell in the measurement


report is greater than the value of this parameter, the
measurement report is valid.

After the valid measurement report is filtered, the 3G


cell joins in the cell priority sequence.

0: 0 dB

1: 6 dB

...

6: 36 dB

7: infinity.

Default value:None
TDDCELLRESELDIV TDD cell Meaning:TDD cell reselect diversity[db]
reselect
diversity[db] Value range:0~15

Explanation:A TDD cell can become a candidate cell


only when the average receive level of the TDD cell
is greater than the TDD Cell Reselect Diversity of
the serving cell.

0: negative infinity (always select a cell if


acceptable)

1: -28 dB

2: -24 dB

...

15: 28 dB.

Default value:None
BESTTDDCELLNUM Best tdd cell Meaning:Best tdd cell number
number
Value range:0~3

Explanation:This parameter specifies the number of


UTRAN TDD cells that should be contained in the
best cell list or in the measurement report.

Default value:None
TDDCELLOFF TDD Meaning:TDD reporting offset
reporting
offset Value range:0~7

Explanation:This parameter specifies the signal level


offset of a TDD cell.

Add the value of this parameter to the receive level


of the TDD cell in the measurement report, and then
sequence the TDD cells.

0: 0 dB

1: 6 dB

...

7: 42 dB.

Default value:None
TDDCELLTHRED TDD Meaning:TDD reporting threshold
reporting
threshold Value range:0~7

Explanation:This parameter specifies the threshold


for determining whether the MR about a TDD cell is
valid.

The measurement report is valid if the receive level


of the TDD cell in the measurement report is greater
than the value of this parameter.

After the valid measurement report is filtered, the


TDD cell joins in the cell prioritization.

0: 0 dB

1: 6 dB

...

6: 36 dB

7: infinity.
Default value:None
TDDSIOPTIMIZEDALL TDD System Meaning:TDD System Information Optimized
OWED Information Allowed
Optimized
Allowed Value range:NO(NO),YES(YES)

Explanation: This parameter specifies whether to


optimize the system information 2Quater and MI of
the TDD neighboring cell. That is, to add an FDD
neighboring cell information before the TDD
neighboring cell information to solve the
compatibility problem of some dual-mode MSs.

Default value:None
TDDMIPROHIBIT TDD MI Meaning:TDD MI System Information Broadcasting
System Prohibit
Information
Broadcasting Value range:NO(NO),YES(YES)
Prohibit
Explanation: This parameter specifies whether to
send the system information MI which contains the
3G neighboring cell information in the TDD
neighboring cell. The value YES(YES) indicates that
the MI is sent, and the value NO(NO) indicates that
the MI is not sent.

Default value:None

Example
Modify the call control parameters related to UTRAN system messages of a cell
(Index Type = BYIDX(By Index); Cell Index = 0):
MOD CELLCCUTRANSYS: IDXTYPE=BYIDX, CELLIDX=0, MSCVER=R99_or_above,
MEASURETYPE=EnhMeasReport, GSMFREQCNUM=2, QI=10, QCI=Always, FDDQOFF=10,
FDDREP=EcN0, FDDFREQCNUM=2, FDDQMIN=4, QP=14, 3GSEARCH=YES, INVALBSICEN=YES,
SCALEORDER=ADD10dB, QSEARCHC=10;
Parent topic: BSC MML Command Reference
Related reference
Add BTS(ADD BTS)
Add Cell(ADD CELL)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

You might also like