The document describes a 149744 Trendmaster Dynamic Scanning Module product datasheet. It provides specifications for the DSM rack, input power requirements, Ethernet and fiber optic card options, and input card specifications. The DSM allows integration with System 1 software and supports Modbus communications for interfacing with process control systems.

Uploaded by

lancasa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
323 views7 pages

Trendmaster DSM Datasheet 149831y

The document describes a 149744 Trendmaster Dynamic Scanning Module product datasheet. It provides specifications for the DSM rack, input power requirements, Ethernet and fiber optic card options, and input card specifications. The DSM allows integration with System 1 software and supports Modbus communications for interfacing with process control systems.

Uploaded by

lancasa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

149744 Trendmaster* Dynamic Scanning Module

Product Datasheet
Bently Nevada * Asset Condition Monitoring

Description
The 149744 Trendmaster* Dynamic Scanning Module
(DSM) is a compact rack-based data acquisition system
that is fully integrated with System 1* software. The
DSM rack has a total of 5 card slots. The first slot is
dedicated for communications and will accept either the
copper or fiber Ethernet card. The second slot is
reserved. The 3rd to 5th slots are TIM Input card or
reserved.
The TIM input card connects to Bently Nevada* TIM and
proTIM* modules. Each TIM input card provides 2 TIM
lines, and each TIM line supports up to 254 channels.
Input cards offer high-resolution sampling with onboard
real-time processing. Onboard processing is the key to
the powerful and efficient features available with the
DSM platform. Because each input card can process
data locally, the DSM can return post-processed
variables to the host computer and reduce the required
network bandwidth. If the host computer requires raw
data, the DSM can also return waveforms and
spectrums.
Modbus Communications Capability
The introduction of a Modbus digital interface now
permits DSMs to communicate directly with process
control and automation systems without the need for
additional hardware. This capability provides a low-cost
entry-level alternative to System 1 that uses the basic
trending and alarming functionality that is integral to
existing process control systems. All DSMs now include
Modbus over TCP/IP capability and require only the DSM
Modbus Exporter software to configure all the DSM
inputs and define the Modbus interface. The DSM
requires the Modbus Serial to Ethernet Bridge for
RS232/485 Modbus communication. See the accessory
section of this datasheet for the Modbus Exporter
software and Serial to Ethernet Bridge part numbers.

Document: 149831
Rev. Y

Page 1 of 7
DSM Features Input Power
Fully integrated with System 1 and Decision 18 watts maximum
Support*
Fuse Rating
Ethernet Modbus server with or without System
1 amp slow-blow
1
Up to 150 DSMs per single data acquisition 10/100 TX Copper Ethernet Card (149776-
computer
01)
Small package, 21cm x 13 cm x 11cm (8.3 in x
Status LED
5.1 in x 4.3 in)
Tri-color LED indicates status of DSM
Choice of copper or fiber Ethernet
and input modules with
Synchronous and asynchronous processing combinations of colors and flash
rates
Automatic self-checking for DSM and Input
cards, and transducers Link/Activity LED
Up to 24 kHz high bandwidth inputs Tri-color LED indicates network link
status
Up to 16-bit high resolution sampling
Connector Type
Up to 16x auto gain
RJ45
TIM (Transducer Interface Module) support for:
Communications
- Acceleration, velocity, and proximity
sensors DSM to System 1
- 4-20 mA, 1-5 V, and 0-10 V transmitters TCP/IP
- J and K thermocouples and platinum RTD UDP for initialization
- Up to 508 channels per card Modbus
Onboard processing for: Operates with or without System1
- True RMS and peak-peak Modbus over TCP/IP
- 1X, 2X, and not 1X variable Up to 6 clients
- User configurable high-pass and band- 0.5 sec response time
pass filters
Baud Rate
- Integrated variables and waveforms
10 Base T or 100 Base TX, auto-
- Configurable spectrums up to 3200 lines negotiating
- Spectrum windowing, averaging, and Cable Length
overlap
100 meters (328 feet)
- Standard and enhanced high-frequency
enveloping Category 5, twisted pair

Specifications 100 FX Fiber Ethernet Card (149776-02)


Status LED
DSM Rack (149744)
Tri-color LED indicates status of DSM
Input Voltage and input modules with
Power connector located on combinations of colors and flash
communications card. rates

20 to 30 Vdc

Document: 149831
Rev. Y

Page 2 of 7
Link/ACT LED A/D Resolution
Tri-color LED indicates network link 14 bits
status
Accuracy
Connector type
2% of full-scale range
MT-RJ
Short Circuit Current Limit
Communications
43 mA maximum
DSM to System 1
Hardware Frequency
TCP/IP Response (3 dB corners)
UDP for initialization 1/3 Hz and 20 kHz
Modbus Refer to TIM and transducer
specifications for more information
Operates with or without System1
Direct Filter
MODBUS over TCP/IP
2-pole high-pass, 1 Hz to 12.8 kHz
Up to 6 clients
Prime Spike Filter
0.5 sec response time
4-pole high-pass, 1 Hz to 12.8 kHz
Operation Protocol
2-pole low-pass, 10 Hz to 12.8 kHz
TCP/IP, BN protocol
Rotor Region Filter
UDP for initialization only
2-pole high-pass, 1 Hz to 12.8 kHz
Baud Rate
2-pole low-pass, 10 Hz to 12.8 kHz
100 base FX only
High Frequency Filter
Cable Length
4-pole high-pass, 1 Hz to 12.8 kHz
400 meters (1312 feet) multimode
fiber optic cable (half duplex)
Synchronous Waveforms (Software
2000 meters (6562 feet) multimode
fiber optic cable (full duplex) configurable)
Frequency Span
TIM Input Card (149787-01) 32, 64, and 128 samples per
Input Lines revolution
Both lines sampled simultaneously 20 to 36,000 CPM
2 lines per card Waveform Size
127 pro-TIMs per line 8192 samples maximum
Filter
Supported TIMs No anti-alias filter on synchronous
path
All proTIM modules
1900/15 Asynchronous Waveforms (Software
1900/25 configurable)
1900/55 Frequency Spans
TIM Cable Length 20 Hz
1200 meters (4000 feet) 50 Hz

Document: 149831
Rev. Y

Page 3 of 7
100 Hz Power supply
200 Hz 0.5 kg (1.1 lbm)
500 Hz Mounting
1000 Hz DIN rail option
2000Hz 35mm DIN rail. Requires 26.7 cm
(10.5 in) rail length.
Sample Rates
Weatherproof
51.2 Hz
housing
128 Hz
35mm DIN rail. Requires 26.7 cm
256 Hz (10.5in.) rail length.
512Hz Bulkhead option
1280 Hz Requires 4 #8 screws required.
2560 Hz Environmental Limits
5120 Hz
Operating Temperature
12800 Hz
-20 C to +65 C (-4 F to +149 F)
25600 Hz
Storage Temperature
Spectral Lines
-40 C to +85 C (-40 F to +185 F)
100
Operating or Storage Humidity
200
95%, non-condensing
400
100% condensing when installed in
800 weatherproof housing with power
applied.
1600
Vibration
3200
2 gs (10 to 55 Hz)
Spectrum averages
10 gs (55 to 500 Hz)
Up to 8
Shock
Windowing
6-inch drop to plywood surface
None, flat-top, or hanning
(installed in terminal base)
General
Dimensions (Length x Compliance and Certifications
Width x Height) EMC
21.6 cm x 13.3 cm x 11.4 cm (8.51 in x Standards:
5.24 in x 4.5 in)
EN 6100-6-2 Immunity for Industrial
Weight Environments
DSM with no input EN 61000-6-4 Emissions for Industrial
cards Environments
0.76 kg (1.7 lbm) EN 61326-1 Electrical Equipment for
Measurement, Control and
Input card
Laboratory use- EMC requirements
0.2 kg (0.44 lbm)

Document: 149831
Rev. Y

Page 4 of 7
European Community Directives: ATEX/IECEx:
EMC Directive 2014/30/EU
Electrical Safety Ex nA IIC T4 Gc
Standards: Ex nA [ic] IIC T4 Gc
EN 61010-1 Ex nA op is [op is T4 Gc] IIC T4 Gc
European Community Directives: T4@ -20 C Ta +65 C
LV Directive 2014/35/EU Entity Parameters [ic] IIC
The equipment must be supplied by a TIM (SPA) Input Card: Um = 30V
limited energy rated power supply.
PWR SIG+/SIG-
Hazardous Area Approvals Uo = 13.37V Uo = 0.2V
Io = 41.7mA Io = 0.018mA
For a detailed listing of country and product specific
approvals, refer to the Approvals Quick Reference Po = 558mW Po = 0.0036mW
Guide (document 108M1756) located at the following Co = 200nF
website: www.GEmeasurement.com. Lo = 0.305mH

North America:

Ex nA IIC T4 Gc
Ex nA [ic] IIC T4 Gc
Class I, Div 2, Groups A, B, C, D
Class I, Zone 2, AEx nA IIC T4 Gc
Class I, Zone 2, AEx nA [ic] IIC T4 Gc
Class I, Zone 2, AEx nA op is [op is T4
Gc] IIC T4 Gc
Class I, Div. 2, Groups A, B, C, D
T4@ -20 C Ta +65 C
When installed per DWG 163796

Document: 149831
Rev. Y

Page 5 of 7
Ordering Information 02200794
+24V Power Supply.
For a detailed listing of country and product specific
162003
approvals, refer to the Approvals Quick Reference
Power Supply to DSM Wiring
Guide (document 108M1756) located at the following
Harness.
website: www.GEmeasurement.com.
162222-01
149744 AXX BXX CXX DXX EXX FXX GXX - HXX
Weatherproof Housing.
A: Power Input
01 110/220 V 50-60 Hz 161692
02 +24 Vdc TIM Line Surge Protector Plug. Also
B: Communication requires Part 161693.
01 10/100baseT Ethernet
161693
02 Fiber Optic Ethernet
C: Input Board 1 TIM Line Surge Protector Base. Also
00 None requires Part 161692.
D: Input Board 2
00 None 03839240
01 TIM input card TIM Line Cable Seal. 5.1 mm to 6.7
E: Input Board 3 mm (0.20 in to 0.27 in).
00 None
01 TIM input card 162261
F: Input Board 4 Trendmaster DSM SPA Cable. Mates
00 None with 162560.
01 TIM input card
G: Mounting 162560
01 Bulkhead mount SPA 5-position DIN Rail Terminal
02 DIN Rail mount Block. Mates with 162261.
03 Weatherproof enclosure
H: Approvals 43501
00 No approvals
Low Pressure Cable Seal.
05 Multiple approvals
(CSA/ATEX/IECEx) 163723

Accessories EMI Ferrite Suppressor. For round


cable.
Use the part numbers listed in this section to order
spare parts or additional components for your 164466-01
Trendmaster DSM system.
Ethernet Component Specification.
3060/56
172555
DSM Modbus Exporter Software.
149776-01 Modbus Serial to Ethernet Bridge.
Spare 10/100 Base T Ethernet
162459-01
Communication Card.
Trendmaster Galvanic Isolator.
149776-02
Spare Fiber Optic Ethernet
149823
Communication Card.
Trendmaster Installation Manual
149787-01 Bently_Manuals
Spare TIM Line Input Card. Customer DVD containing all Bently
Manuals, FWD, App Notes, and Install
149833-01 Guides in all available languages
Blank Slot Cover.

Document: 149831
Rev. Y

Page 6 of 7
Graphs and Figures
Note: All dimensions shown in millimetres (inches) except as noted.

L = 370 mm (14.55 in)


H = 274 mm (10.00 in)
W = 319 mm (12.55 in)
G = 379 mm (14.94 in)
J = 165 mm (6.5 in)
K = 46 mm (1.61 in)
Q = 260 mm (10.25 in)

Figure 1: Weatherproof Housing Dimensions

2002 2017 Bently Nevada, LLC All rights reserved.


* Denotes a trademark of Bently Nevada, LLC, a wholly owned subsidiary of General Electric Company.
All product and company names are trademarks of their respective holders.
Use of the trademarks does not imply any affiliation with or endorsement by the respective owners
The information contained in this document is subject to change without notice.
Printed in USA. Uncontrolled when transmitted electronically.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 775.782.3611 www.GEmeasurement.com

Document: 149831
Rev. Y

Page 7 of 7

You might also like