0% found this document useful (0 votes)
140 views

Boiler Calc

This document provides input parameters and calculations for determining chemical treatment requirements for two steam boilers. Key inputs include operating pressure, load, hours of operation per day and year, and water quality parameters. Based on these inputs and a desired concentration ratio, the summary calculates the daily and annual dosages required of various water treatment chemicals, including Nexguard 22312, N77211, and N2813, to control issues like hardness, iron dispersion, and sulfite residuals. The total annual quantities of each chemical are also summarized.

Uploaded by

Bhavana Kewlani
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views

Boiler Calc

This document provides input parameters and calculations for determining chemical treatment requirements for two steam boilers. Key inputs include operating pressure, load, hours of operation per day and year, and water quality parameters. Based on these inputs and a desired concentration ratio, the summary calculates the daily and annual dosages required of various water treatment chemicals, including Nexguard 22312, N77211, and N2813, to control issues like hardness, iron dispersion, and sulfite residuals. The total annual quantities of each chemical are also summarized.

Uploaded by

Bhavana Kewlani
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

Filter Criteria Steam Boilers

Inputs Pressure

Inputs Load

Inputs Operating Hours / day

Inputs Operating Days / year

Inputs Boiler Desired Concentration ratio (NC)

Inputs Feed Tank Temperature

Inputs Make-up Hardness

Inputs Make-up Water TDS

Inputs Condensate ReturnTDS

Inputs Feed Water TDS

Inputs Boiler TDS @ Desired NC

Inputs Make-up rate (Meter reading, if unknown leave blank)


Boiler 1
8 Ton
8 Bar

50% 4 Ton/hour

24 hours

365 Days

o (NC) 15 Unitless

95 C

0 ppm

220 ppm

25 ppm

125 ppm

1875 ppm

unknown leave blank) m3/day


Boiler 1 Boiler 2
Filter Criteria 18 18 Ton
Nexgaurd 22312 Nexguard 22312
Nexgaurd 22312 Limiting Pressure 41 Bar
Nexgaurd 22312 Applicable For Boiler 1

Nexgaurd 22312 Applicable For Boiler 2

Nexgaurd 22312
Trasar Product Factor 40
Nexgaurd 22312 Boiler 1 Boiler 2
Nexgaurd 22312 Dosage required for Hardness Control 0.00 0.00 ppm

Nexguard 22312 Iron Dispersion Dosage 1.53 1.53 Kg/day


Nexgaurd 22312
Nexgaurd 22312 Dosage required 1.53 1.53 Kg/day
Nexgaurd 22312 Total Dosage required 3.06 Kg/day
Nexgaurd 22312 Annual Quantity of N22312 558.45 558.45 Kg/Year
Nexgaurd 22312 Total Annual Quantity of N22312 1116.90 Kg/Year
N77211 N77211 (Sulphite)
N77211 Limiting Pressure 60 Bar
N77211 Applicable For Boiler 1
N77211 Applicable For Boiler 2
N77211 Boiler 1 Boiler 2

N77211 Average Sulphite residual required 35.00 35.00 ppm


N77211
N77211 Dosage required 1.77 1.77 Kg/day
N77211 Total Dosage required 3.53
N77211 Annual Quantity of N 77211 645.0 645.0 Kg/Year
N77211 Total Annual Quantity of N 77211 1290.0 Kg/Year
N2813 N2813 Tri Act
N2813 Boiler 1 Boiler 2

N2813 Dosage required 3.73 3.73 Kg/day


N2813 Total Dosage required 7.45 Kg/day
N2813 Annual quantity of N 2813 1360.3 1360.3 Kg/Year

N2813 Total Annual quantity of N 2813 2720.7 Kg/Year