EMLock 1500 Series

SDCs patented EMLock design represents the


pinnacle of magnetic lock evolution. The modular
EMLock assembly makes them easy to stock,
install, upgrade and maintain.

Modular Design
Modular Upgrade Kits Patented
Field Upgradeable without removing from the frame
Uniform Design & Installation
Identical Housing, Template & Accessories
Quick Mount Assembly
New Modular Kits
SDC 1500 series EMLocks include a lifetime warranty
For complete details contact SDC to request the Modular Upgrade Kit datasheet
and are available in 650lbs, 1200lbs, and 1650lbs holding or download from the SDC website: www.sdcsecurity.com/docLibrary.aspx
force. Compatible with any access control system, all
EmLocks are adaptable to virtually any application
utilizing Top Jamb or Glass Door mounting kits. The
epoxy-less design provides a superior appearance with a
plated or anodized finish on all sides. The interlocking EZ
mount assembly leaves hands free for wiring and securing EZ-T-10
of mounting screws. EMLocks are UL Listed and ANSI Timer Input Module
Grade 1 compliant.

EMLock EZ Upgrade Kits


+ 34 56 78

Field upgradeable by distributors, installers and


maintenance staff. No need to ever remove a lock from
the frame to upgrade or exchange internal components.

Upgrade Modules Include: EZ-B-10


Magnetic Bond Sensor
Relock Delay Timer
Magnetic Bond Sensor
Door Status Sensors
Anti-Tamper Switch
Holding Force Upgrade
+ 34 56 78

Energy Saver Upgrade


EZ-A
Anti-Tamper Switch

CSFM
I S T I NG

MEA
L OF
CALIF
O
E
RN
T
S TA

IA
L
ST

Listed EZ-D-10
HA
AT

E
S

FIR R
S E MA
E

ER
VIC
Be Safe. Be Secure. Be Certified
LISTED Door Position Sensor

Online System Wizard and Project Manager at


www.SDCsecurity.com

Patent 5,376,910
EMLock Models

1510 Series Grade 1 1570 Series Grade 1 1580 Series Grade 1


1650 lb / 748 Kg Holding Force 1200 lb / 544 Kg Holding Force 650 lb / 295 Kg Holding Force
3 Watts Energy Saver

1581
1571
1511

1582
1512 1572

1513 1573

1511 Single EMLock 1571 Single EMLock 1581 Single EMLock


1512 Double EMLock 1572 Double EMLock 1582 Double EMLock
1513 Single, split armature for pair of doors 1573 Single, split armature for pair of doors

Specifications Specifications Specifications


Voltage: 12/24VDC Voltage Sensing Input Voltage:12/24VDC Voltage Sensing Input Voltage: 12/24VDC Voltage Sensing Input
Single: 350mA @ 24VDC; 670mA @ 12VDC Single: 125mA @ 24VDC; 250mA @ 12VDC Single: 220mA @ 24VDC; 440mA @ 12VDC
11" L x 2.75" H x 1-9/16" D 11"L x 2-3/4"H x 1.562"D 8-3/4"L x 2-1/8"H x 1.25"D
(279.4 x 69.9 x 39.7 mm) (279.4 x 69.9 x 39.7 mm) (222.2 x 54 x 31.8 mm)
Double: 700mA @ 24VDC; 1.34A @12VDC Double: 250mA @ 24VDC; 500mA @ 12VDC Double: 440mA @ 24VDC; 880mA @ 12VDC
22" L x 2-3/4" H x 1-9/16" D 22" L x 2-3/4" H x 1-9/16" D 17-1/2" L x 2-1/8" H x 1.25" D
(558.8 x 69.9 x 39.7 mm) (558.8 x 69.9 x 39.7 mm) (444.5 x 54 x 31.8 mm)

Standard Mounting Fasteners


Self Drilling & Tapping Sheet Metal Screws and 10/32 Machine Screws supplied for different application needs. Blind Nuts and Tool are optional.

Listings & Performance Specifications


UL Listed U.S. & Canada: GWXT Auxiliary Locks ANSI/BHMA A156.23: Grade 1, one million cycles
CVXJ Burglary Resistant Electrically Operated Door Lock BHMA Certified
UL10C: Position Positive Pressure Compliant CSFM: California State Fire Marshal Listed 3774-0324:100
UBC: Classified in accordance with Uniform Building Code standard 7-2 MEA: City of New York 61-95-E
Fire Test for Door Assemblies

Finish

Finishes Plated Finishes (special order)


V 628 Aluminum (standard) C 605 Bright brass P 625 Bright chrome
X Dark bronze powder coat (313/613 equal) D 606 Dull brass Q 626 Dull chrome
Y 335 Black anodized

Factory Installed Options



T Adjustable Timer: Built-in field adj. 0-30 sec. re-lock delay. Specify one for single or double EMLocks (not available with 1580 series)
D Door Position Sensor: Indicates door open and door closed. Specify two for double EMLocks (not available with 1513 and 1573) SPDT
Dry, 250 mA @ 30VDC.
B Magnetic Bond Sensor: Indicates locked and unlocked, low holding power, tampering and obstruction between armature and magnetic core.
Specify (2) for double EMLocks (Not available with 1513 and 1573)
1510 & 1570 Series: SPDT Dry, 250 mA @ 30VDC. 1580 Series: SPST N.O., Dry, 250 mA @ 30VDC.
L Bi-color Status LED Indicator: Field selectable Red, Green, or Amber (requires additional wiring)
Indicates lock energized when wired to lock input.
Indicates de-energized/unlocked or Enter/Go when wired to optional timer module.
Indicates energized and de-energized or Enter/Go when wired to access control auxiliary output.
Indicates door is closed and locked and door is unlocked when wired to BA.
A Anti-tamper Sensor: Indicates access cover removal. SPDT Dry, 1 Amp @ 30VDC.
Field Installed Option Kits

Ordered separately for field upgrade


For complete details contact SDC to request the Modular Upgrade Kit datasheet or download from the SDC website: www.sdcsecurity.com/docLibrary.aspx
All available through shipQuick Inventory
EZ-T-10 Adjustable Timer Input Module: Specify (1) for single or EZ-A Anti-Tamper Switch Module: Indicates cover plate removal.

double EmLocks (not available with 1580 series) EZ-1510W Holding Force Module: Exchange a 1200lb wire coil (1570
EZ-D-10 1510, 1570 Door Position Sensor Module: Specify (2) for series) with this 1650lb wire coil. Specify (2) for double EMLocks
double EMLocks (not available with 1513 and 1573)
EZ-1570W Energy Saver Module: Save on power supply and long term
EZ-D-80 1580 Door Position Sensor Module: Specify (2) for
energy costs by exchanging 8.4 Watt, 1650lb coil with 3 Watt,
double EMLocks
1200lb holding force coil. Specify (2) for double EMLocks
EZ-B-10 1510, 1570 Magnetic Bond Sensor Module: Specify
(2) for double EMLocks (Not available with 1513,1573)
EZ-B-80 1580 Magnetic Bond Sensor Module: Specify (2) for
double EMLocks

Top Jamb Mounting Brackets Universal Glass Door Mounting Kit Door Coordinator Lock Mounting Kit

See page 2 for available finish See page 2 for available finish DC-1 Door coordinator mounting bracket
Kits for 1511, 1512, 1571, 1572 Locks Kit for 1511, 1571, 1581 for single models 1511 and 1571.
TJ1 Single HDB1 Single DC-2 Door coordinator mounting bracket
for double models 1512 and 1572.
TJ2 Double Kit for 1512, 1572, 1582
Kits for 1581, 1582 Locks HDB2 Double, 2 single kits DC-1
TJ81 Single
TJ82 Double
DC-2

SDC Door Door


Coordinator Coordinator
Bracket

Adjustable brackets
SDC Door
Adjustable for glass thickness Coordinator
Door
Coordinator
Bracket
brackets

Architectural Housings

Specify housings with your EMLocks. Example: 1511V-30; 1512V-60


Full Width Housings - appear as part of the frame to provide a superior architectural appearance.
Compatible with Models: 1511, 1512, 1571, 1572 with or without HDB kits or TJ brackets.
Vertical Housings - Side jamb mount, accommodates two 1571 or two 1511 EMLocks providing 2400 or 3300 lbs of holding force.
See page 2 for available finish
Single Door Housing Double Door Housing Vertical Housings
30 30" Lock housing 60 60" Lock housing V82 82" high opening
36 36" Lock housing 72 72" Lock housing CV Custom length.
40 40" Lock housing 84 84" Lock housing Specify exact length
48 48" Lock housing 96 96" Lock housing
CH Custom length. Specify exact length CH Custom length. Specify exact length
Reusable Heavy Duty Blind Nut Interlocking Quick Mount Assembly
Drill Fixture Placement Tool
1511-DF Heavy duty drill BN-PT Blind Nut
fixture for 1571 and Placement Tool
1511 BN-50 Blind Nuts,
1581-DF Heavy duty drill 10/32, 50 Pack
fixture for 1580

Typical Door Applications

4" FRAME

2007 Security Door Controls


2007 Security Door Controls

1511 1571 1581 1511 1571 1581 1513 1573

.  %#("* .&##&,$*#($ .'# *($*+(


. #+$ %+$($ .&&&##&,$*#&&( .&##&,$*#($
. #+$ %+$#))&&( .+)) $&+%* % .&&&(&##&,$*#&&()
.+)) $&+%* % .+)) $&+%* %

2006 Security Door Controls 2006 Security Door Controls 2006 Security Door Controls

2007 Security Door Controls


2007 Security Door Controls

1511-HDB1 1571-HDB1 1581-HDB1 1511-TJ1 1571-TJ1 1581-TJ81 1512 1572 1582

.#))&&($&+%* %" * .&'!$$&+%* %" * .&##&,$*#($


. )( )%#("*) .&##&,$*#($ .&&&(&##&,$*#&&()
.*#&(#+$ %+$($ .&&&(&##&,$*#&&( .+)) $&+%* %
.#))&&(,&*&'( # .+##) $&+%* %
.+)) $&+%* %

2006 Security Door Controls

4" FRAME

2007 Security Door Controls 2007 Security Door Controls

1511-(36) 1571-(36) 1512 1572 1582 1512-HDB2 1572-HDB2 1582-HDB2

.+##, *( **+(#&+) % .  %#("* .#))&&($&+%* %" *


.' -#%*  

 . #+$ %+$($ . )( )%#("*
. #+$ %+$($ . #+$ %+$#))&&() .*#&(#+$ %+$($
. #+$ %+$#))&&( .+)) $&+%* % .#))&&(, *&+**&'( #
.+)) $&+%* %
.+)) $&+%* %
Pre-Drille & Tapped Header Bracket

Used in lieu of angle brackets, the Universal Header Bracket provides a faster mounting solution, saving time and labor costs for several EMLock
models. Reduce potential for mis-sized and misaligned mounting holes, broken taps, removal of broken taps. Combined with the interlocking E-Z
mount assembly, save up to a full days labor with the installation of 20 locks.
Solid 1" bar provides higher security and superior aesthetics.
Machined wire chase provides concealed and secure wiring
Multiple pre-drilled and tapped mounting holes to accommodate the use of several different locks on either 4" or 4.5" aluminum frames
See page 2 for available finish
UB11 1" x 1" x 11" Universal Bracket for 1511, 1513, 1571, 1573, 1511S, 1511T, 1511DE, 1571DE
UB12 1" x 1" x 22". Universal Bracket for 1512 and 1572.
4" FRAME 4-1/2" FRAME

Machined Pre drilled and Tapped


Holes Pre drilled & Countersunk
Wire Chase Lock Mounting Holes
For Frame Mounting

Spacer Bracket For Concrete Filled Frames & Aluminum Frame With Blade Stop

Aluminum frames with blade stop - lowers EMLock below blade stop
Machined wire chase provides multiple points for concealed wire entry from concrete filled frames Aluminum frame with Hollow metal
1/2" blade stop concrete filled
Pre-drilled and tapped specifically for 1510, 1570, and 1580 EmLock frame
Aluminum Finish

UF11V 1/2" x 1-1/2" x 11". Spacer Bracket for 1511, 1513, 1571, 1573, 1511S, 1511DE, 1571DE.
UF12V 1/2" x 1-1/2" x 22". Spacer Bracket for 1512 and 1572.
UF81V 1/2" x 1-1/4" x 8-3/4". Spacer Bracket for 1581.
UF82V 1/2" x 1-1/4" x 17-1/2". Spacer Bracket for 1582.

UF11V UF81V

Armature Mounting Plate

The AR Mounting plate provides a solution for mounting the EMLock armature to the top rail of herculite, aluminum and glass, wood and hollow
metal doors that do not permit the use of thru bolts. Available in black finish.
AR11Y Armature mounting plate for 1511, 1571. 335 Black Anodized (Specify two for models 1512, 1572)
AR11YD Armature mounting plate with DPS for 1511, 1571. 335 Black Anodized (Specify two for models 1512, 1572)

Glass
Door
Wood
Wood Top
or
Or
Lock Rail
Metal
Metal
Door
Door
Glass

Armature
Armature
Mounting Plate
Mounting
Plate
sdcsecurity.com [email protected]

Filler Plates Angle Brackets

For extension of the stop to provide a proper mounting surface on Used as extension on shallow door frames to provide adequate
the underside of the header See Figure 1B. mounting surface. See Figure 1C.

For Extension Of The Stop To Provide A Proper Mounting Surface On Used As Extension On Shallow Door Frames To Provide Adequate
The Underside Of The Header See Figure 1b. Mounting Surface. See Figure 1c.

For 8-3/4 Single Emlock & Exit Check Models For 8-3/4 Single Emlock & Exit Check Models
1581, 1581DE 1581, 1581DE
PART # A x B PART # A x B
FP01 1/8" x 1-1/4" (3 x 32mm) AB01 1" x 1" (25 x 25mm)
FP02 1/4" x 1-1/4" (6 x 32mm) AB02 1" x 1-1/2" (25 x 38mm)
FP03 3/8" x 1-1/4" (10 x 32mm) AB03 1-1/2" x 1-1/2" (38 x 38mm)
FP04 1/2" x 1-1/4" (13 x 32mm) AB04 2" x 1-1/2" (51 x 38mm)
FP05 5/8" x 1-1/4" (16 x 32mm) For 10-11 Single Emlock & Exit Check Models
For 10-11 Single Emlock & Exit Check Models 1511, 1513, 1571,
1511, 1513, 1571, 1581S, 1511S, 1511T, 1511DE, 1571DE
1581S, 1511S, 1511T, 1511DE, 1571DE PART # A x B
PART # A x B AB11 1" x 1" (25 x 25mm)
FP11 1/8" x 1-1/4" (3 x 32mm) AB12 1" x 1-1/2" (25 x 38mm)
FP12 1/4" x 1-1/4" (6 x 32mm) AB13 1-1/2" x 1-1/2" (38 x 38mm)
FP13 3/8" x 1-1/4" (10 x 32mm) AB14 2" x 1-1/2" (51 x 38mm)
FP14 1/2" x 1-1/4" (13 x 32mm)
For 17-1/2" (445mm) Double Emlock Model 1582
FP15 5/8" x 1-1/4" (16 x 32mm)
PART # A x B
For 17-1/2" (445mm) Double Emlock Model 1582 AB30 1" x 1" (25 x 25mm)
PART # A x B AB31 1" x 1-1/2" (25 x 38mm)
FP30 1/8" x 1-1/4" (3 x 32mm) AB32 1-1/2" x 1-1/2" (38 x 38mm)
FP31 1/4" x 1-1/4" (6 x 32mm) AB33 2" x 1-1/2" (51 x 38mm)
FP32 3/8" x 1-1/4" (10 x 32mm)
For 22" (559mm) Double Emlock Models 1512 / 1572
FP33 1/2" x 1-1/4" (13 x 32mm)
PART # A x B
FP34 5/8" x 1-1/4" (16 x 32mm)
AB21 1" x 1" (25 x 25mm)
For 22" (559mm) Double Emlock Models 1512 / 1572 AB22 1" x 1-1/2" (25 x 38mm)
PART # A x B AB23 1-1/2" x 1-1/2" (38 x 38mm)
FP21 1/8" x 1-1/4" (3 x 32mm) AB24 2" x 1-1/2" (51 x 38mm)
FP22 1/4" x 1-1/4" (6 x 32mm)
FP23 3/8" x 1-1/4" (10 x 32mm)
FP24 1/2" x 1-1/4" (13 x 32mm)
A
FP25 5/8" x 1-1/4" (16 x 32mm) B
B
A
A A
B B
B B
A A

2" 2" 2"


51mm 51mm 51mm

2" 2" 2 5/16" 2" 2" 2 5/16" 2" 2" 2 5/16"


51mm 51mm 51mm 51mm 51mm 51mm
59mm 59mm 59mm
2 5/16" 2 5/16" 2 5/16" 2 5/16" 2 5/16" 2 5/16"
59mm 59mm 59mm 59mm 59mm 59mm

www.sdcsecurity.com [email protected]
SECURITY DOOR
SECURITY CONTROLS
DOOR CONTROLS [t] 800.413.8783 805.494.0622 [f] 805.494.8861
801 Avenida Acaso! ) x 3670, Camarillo CA 93011-3670
2007 Security Door Controls LIT-EMLock Brochure 10/07
EZ Option Upgrade Kits - Emlock 1511, 1513, 1571, 1573

EMLock EZ Kits
Field Upgradeable Option Modules for 1511, 1513, 1571, 1573
SDCs patented EMLock design represents the pinnacle of magnetic lock evolution. FIELD UPGRADE
The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Relock Delay Timer
Magnetic Bond Sensor
Field Upgradeable by Distributors, Installers and Maintenance Staff Door Status Sensors
No need to ever remove a lock from the frame to upgrade or exchange Anti-Tamper Switch
internal components. Holding Force Upgrade
Energy Saver Upgrade

EZ-T-10 TIMER INPUT MODULE EZ-B-10 MAGNETIC


Modular Kit BOND SENSOR
Modular Kit

EZ-D-10: DOOR POSITION SENSOR EZ-A: ANTI-TAMPER SWITCH


Modular Kit Modular Kit

SECURITY DOOR CONTROLS


sdcsecurity.com [email protected]
sdcsecurity.com [email protected]

EZ-T-10 TIMER INPUT MODULE


Modular Kit
Relock Delay Timer, Adjustable 1 to 30 Seconds.

Application: The Timer Input Module delays relocking of access controlled doors to provide persons ample time needed
for entry or egress. Momentary interruption of power to the lock input activates the timer module.

Momentary, N.C. Dry Contact required. Contact actuation unlocks the door for 1 30 seconds.

www.sdcsecurity.com [email protected]
SECURITY DOOR
SECURITY CONTROLS
DOOR CONTROLS [t] 800.413.8783 805.494.0622 [f] 805.494.8861
8801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
2007 Security Door Controls Printed in the U.S.A. LIT-Datasheet date qty vendor
EZ Option Upgrade Kits - Emlock 1511, 1513, 1571, 1573

EZ-B-10 MAGNETIC BOND SENSOR


Modular Kit
* Not available for 1513, 1573
While a Door Status Sensor indicates the door is open Application: Lock secure status annunciation,
or closed, SDCs Magnetic Bond Sensor provides higher mantrap system logic,
security monitoring by indicating the locked / unlocked CCTV camera activation.
mode, tampering and low holding force. The use of
both the door status and magnetic bond sensor is Output: SPDT Dry Contact,
recommended for high security applications. 250 mA @ 12/24VDC

SECURITY DOOR CONTROLS


sdcsecurity.com [email protected]
sdcsecurity.com [email protected]

EZ-D-10: DOOR
POSITION SENSOR
Modular Kit
Indicates the door is open
and closed.

* Not available for 1513, 1573


Application:
Door position status annunciation,
anti-tailgating, interlock, mantrap and
communicating bathroom system
logic.

Output:
SPDT Dry Contact, 250 mA
@ 12/24VDC

EZ-A: ANTI-TAMPER
SWITCH - Modular Kit
Indicates cover plate removal

Output:
SPDT Dry Contact, 3 Amp @ 12/24VDC

www.sdcsecurity.com [email protected]
SECURITY DOOR
SECURITY CONTROLS
DOOR CONTROLS [t] 800.413.8783 805.494.0622 [f] 805.494.8861
8801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
2007 Security Door Controls Printed in the U.S.A. LIT-Datasheet date qty vendor
EZ Option Upgrade Kits - Emlock 1511, 1513, 1571, 1573

EZ 1510W Holding Force Upgrade


EZ 1570W Energy Saver Upgrade
All 1511, 1512, 1513, 1571, 1572 and 1573 magnetic coils are field interchangeable without removing the lock from the frame. There is no reason
to remove and ship a lock for exchange.
Benefits of this interchangeability include: Applications
Distributors with limited stock may exchange coils to fulfill specific
EZ-1510W Holding Force Upgrade: Exchange 1200 lb coil with special sales needs, i.e. a 1570 with Dark Bronze finish may be
1650 lb holding force coil upgraded to a 1511 with dark bronze finish and visa versa.
EZ-1570W Energy Saver Upgrade: Save on power supply and
Installers may field upgrade to an Energy Saver where power supply
long term energy costs by exchanging 8.4 Watt,1650 lb coil
capacity is limited or upgrade to higher holding force where 1200 lbs
with 3 Watt, 1200 lb holding force coil
holding force proves inadequate, i.e. psychiatric or rehab center
Eliminate labor, shipping costs and time associated with special applications.
orders or complete lock removal and replacement.

SECURITY DOOR CONTROLS


sdcsecurity.com [email protected]
sdcsecurity.com [email protected]

www.sdcsecurity.com [email protected]
SECURITY DOOR
SECURITY CONTROLS
DOOR CONTROLS [t] 800.413.8783 805.494.0622 [f] 805.494.8861
8801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
2007 Security Door Controls Printed in the U.S.A. LIT-Datasheet date qty vendor
EZ Option Upgrade Kits - Emlock 1512 / 1572

EMLock
module to each EZ Upgrade
armature Kits 2 Re-install armature per installation instructions
Field Upgradeable Option Modules for 1512 and 1572
SDCs patented EMLock design represents the pinnacle of magnetic lock evolution. FIELD UPGRADE
The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Relock Delay Timer
Magnetic Bond Sensor
Field Upgradeable by Distributors, Installers and Maintenance Staff Door Status Sensors
No need to ever remove a lock from the frame to upgrade or exchange Anti-Tamper Switch
internal components. Holding Force Upgrade
Energy Saver Upgrade

EZ-T-10 TIMER INPUT MODULE EZ-B-10 MAGNETIC


Modular Kit BOND SENSOR
5 Modular Kit
5 Attach magnetic core 6 Position timer modules
wire connector to between posts

+ 34 56 78
timer module

T - Timer input
module

Connect
output wires The Magnetic Bond
of timermodule Sensor should be
positioned as shown Cra
to input terminals Position Po
1 and 2 of standards below, after step 4.
EZ-D-10: DOOR POSITION SENSOR
input
1 Attach door status module to each
module.
armature
EZ-A: ANTI-TAMPER SWITCH
2 Re-install armature per in
Modular Kit 2 Modular Kit

9 Attach cover plate.


9 Attach cover plate

SECURITY DOOR CONTROLS


sdcsecurity.com [email protected]
Place anti-tamper switch as shown.
1 Remove cover plate screws

sdcsecurity.com [email protected]

1 only required
EZ-T-10 TIMER INPUT MODULE
1 Remove cover plate screws 1 Modular Kit 2
Remove cover plate screws Remove cover plate 2 Remove cover plate

Relock Delay Timer, Adjustable 1 to 30 Seconds. 1 only required for double EMLock.

Application: The Timer Input Module delays relocking of access controlled doors to provide persons ample time needed
for entry or egress. Momentary interruption of power to the lock input activates the timer module.

Momentary, N.C. Dry Contact required. Contact actuation unlocks the door for 1 30 seconds.
Only 1 timer module is required for double Emlocks.

screws 1 Remove cover plate


2 Remove
screwscover plate 2 Remove cover plate 2 Remove cover plate
3 Carefully lift input 3 Carefully lift input
modules from case modules from case

3 Carefully lift input 4 Disconnect magnetic 4 Disconnect magnetic


5 Attach
Standard
magnetic core Standard
input module input module
modules from case cord wires and remove cord wires and remove
wire connector to
input module input module timer module
Standard
T - Timer input
input module
module

Connect
output wires
of timermodule
to input terminals
1 and 2 of standards
5 Attach magnetic core
4 Disconnect magnetic 5 Attach magnetic core 6 Position timer modules 6input
Position timer modules
module.
wire connector to
cord wires and remove wire connector to between posts between posts
input module timer module timer module
T - Timer input T - Timer input
module module

Connect Connect
output wires output wires PC Board
of timermodule of timermodule
Cradle Cradle
to input terminals to input terminals Position Posts Position Posts
1 and 2 of standards 1 and 2 of standards
e 5 Attach magnetic 6core
Position timer modules 6 Position
input timer modules
module. 6 Position
input 7 Adjustable 1 - 30 Seconds
timer modules
module. 7 Adjustable 1 - 30 Seconds
wire connector to between posts between posts between posts Typical factory setting approximately
Typical
5 seconds
factory setting approxi
timer module Turn clockwise to increase time Turn clockwise to increase tim
econds 7 Adjustable
T - Timer input 1 - 30 Seconds 8 T - Timer module wiring 8 T - Timer module wiring
9 Attach cover plate
ng approximately
Typical
5 seconds
module factory setting approximately 5 seconds B Option B Option
Connector Connector
ncrease time Turn clockwise to increase time
LOCKED - NO LOCKED - NO
B Option B Option
Magnetic Bond Sensor COM Magnetic Bond Sensor COM D2 D2

UNLOCKED - NC UNLOCKED - NC
Connect Connect
CLOSED - NO CLOSED - NO
output wires output wires PC Board D Option COM PC BoardD Option COM PC Board
Door Status Sensor Door Status Sensor
of timermodule of timermodule OPEN - NC OPEN - NC
Cradle Cradle Cradle
to input terminals to inputPosition
terminals
D2

Posts 12 or 24 VDC Position Posts 12 or 24 VDC Position Posts


1 and 2 of standards 1 and 2 of standards
input module. input module. Access and Egress Control Access and Egress Control
Magnetic Core Magnetic Core
Momentary Connector
Momentary Connector
N.C. Dry Contact N.C. Dry Contact
Contact actuation unlocks Contact actuation unlocks
8 T - Timer module9wiring
Attach cover plate 9 Attach cover
doorplate
for 1 - 30 seconds door for 1 - 30 seconds
B Option
Connector

LOCKED - NO
B Option
Magnetic Bond Sensor COM
UNLOCKED - NC
CLOSED - NO
D Option COM
Door Status Sensor
OPEN - NC

12 or 24 VDC

Access and Egress Control


Magnetic Core
Momentary Connector
N.C. Dry Contact
Contact actuation unlocks www.sdcsecurity.com [email protected]
SECURITY
9 Attach DOOR CONTROLS
SECURITY DOOR CONTROLS
cover
doorplate
for 1 - 30 seconds
[t] 800.413.8783 805.494.0622 [f] 805.494.8861
8801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
2010 Security Door Controls Printed in the U.S.A. LIT-EZ Option Kit Upgrades 12.10
1 Remove cover plate screws.
EZ Option Upgrade Kits - Emlock 1512 / 1572

Specify 2 for 1512, 1572


EZ-B-10-2 MAGNETIC BOND SENSOR
1 Remove cover plate screws.
1 Modular Kit 2
Remove cover plate screws. Remove
cover plate.
2 Remove
cover plate.
While a Door Status Sensor indicates the door is open Application: Lock secure status annunciation,
or closed, SDCs Magnetic Bond Sensor provides higher mantrap system logic,
security monitoring by indicating the locked / unlocked CCTV camera activation.
mode, tampering and low voltage. The use of
both the door status and magnetic bond sensor is Output: 2 Contacts provided
recommended for high security applications. 2-SPDT Dry Contact,
250 mA @ 12/24VDC
ver plate screws. 1 Remove cover plate2 screws.
Remove 2 Remove 2 Remove 3 3
cover plate. cover plate. cover plate.

+ 34 56 78

+ 34 56 78
3 4 Remove 2 screw 4 Remove 2 screw 5
from the case from the case
+ 34 56 78
+ 34 56 78

bottom. bottom.

+ 34 56 78
Place the Place the
Magnetic Bond Magnetic Bond
Sensors at the Sensors at the
base of each base of each Lift input module Li
Magnetic Core. Magnetic Core. and magnetic coil an
from the case. fr
Secure sensor Secure sensor
The Magnetic Bond
Lift input module Lift input module in place with in place with
Sensor should be
and magnetic coil and magnetic coil screw as screw as
positioned as shown
from the case. from the case. shown.
4 Remove 2 screw 5 5 shown. 6 Place magnetic coil firmly below,
6 Place magnetic
after step 4. coil firmly
from the case between core lamination between core lamination
+ 34 56 78

+ 34 56 78

bottom. as shown. as shown.

Place the
Magnetic Bond
Sensors at the
base of each
Magnetic Core. Connect
magnetic
Secure sensor The Magnetic Bond The Magnetic Bond bond sensor
in place with Sensor should be Sensor should be wires to the input
screw as positioned as shown positioned as shown module B Option
shown.
5 6 Place magnetic coil firmly below,
6 Placeafter step 4.coil firmly below,
magnetic 6 Placeafter step 4.coil firmly
magnetic 7 Place input module vertically 7 Placeasinput
connector module vertical
shown. con
between core lamination between core lamination between core lamination between post at each between post at each
+ 34 56 78

+ 34 56 78

as shown. as shown. as shown. side of case. side of case.


odule vertically 7 Place input module vertically 8 Input module wiring. 8 Input module wiring.
9 Attach cover plate.
at each between post at each
side of case. B Option B Option
+ 34 56 78

+ 34 56 78
Connector Connector

LOCKED - NO LOCKED - NO
Connect
B Option
COM
Connect
B Option
COM
Connect
Magnetic Bond Sensor Magnetic Bond Sensor
magnetic UNLOCKED - NC magnetic UNLOCKED - NC magnetic
+ 34 56 78
+ 34 56 78

PC Board
ond The Magnetic Bond The Magnetic Bond bond sensor CLOSED - NO bond sensor CLOSED - NO bond sensor
D Option D Option
be Sensor should be Sensor should be wires Door
to the input
Status Sensor
COM
wires toDoor
the input
Status Sensor
COM
wires to the input Cradle Cradle
OPEN - NC OPEN - NC Position Posts Position Posts
own positioned as shown positioned as shown module B Option module B Option module B Option
p 4. below, afterPCstep
Board
4. below, after step 4.
PC Board connector as shown.
12 or 24 VDC connector as12shown.
or 24 VDC connector as shown.
Cradle Cradle
Position Posts Position Posts Magnetic Core Magnetic Core
Connector Connector
8 Input module wiring.9 Attach cover plate. 9 Attach cover plate.

B Option
Connector

LOCKED - NO
B Option
Magnetic Bond Sensor COM
UNLOCKED - NC
CLOSED - NO
SECURITY DOOR CONTROLS
D Option COM
Door Status Sensor
OPEN - NC
sdcsecurity.com [email protected]
12 or 24 VDC
sdcsecurity.com [email protected]

1 Attach door status module to each


1 Attach
armature
door status module to each armature 2 Re-install armature per installation
2 Re-install
instructions
armature per install

EZ-D-10-2: DOOR
1 Attach
odule to each
POSITION SENSOR
armature
door status module to each armature 2 Re-install armature per installation
2 Re-install
instructions
armature per installation instructions 3 Input module wiring.

B Option
Connector

Modular Kit B Option


Magnetic Bond Sensor
LOCKED - NO
COM
UNLOCKED - NC

Indicates the door is open D Option


CLOSED - NO
COM

and closed.
Door Status Sensor
OPEN - NC

12 or 24 VDC

Application:
er installation instructions 3 Input module wiring. 3 Input module wiring. 4 Annunciation 4 Annunciation
Door position status annunciation, B Option B Option
anti-tailgating, interlock, Connector mantrap Connector

and communicating
3 Input module wiring. bathroom
B Option
LOCKED - NO 4 Annunciation
B Option
LOCKED - NO 4 Annunciation
system logic. Magnetic Bond Sensor COM Magnetic Bond Sensor COM
B Option UNLOCKED - NC UNLOCKED - NC
Connector CLOSED - NO CLOSED - NO
D Option COM D Option COM
Door Status Sensor Door Status Sensor
ED - NO Output: 2 Modules provided
B Option
LOCKED - NO
OPEN - NC OPEN - NC
COM COM
ED - NC SPDT Dry Contact, 250 mA
Magnetic Bond Sensor 12
UNLOCKED - NC
or 24 VDC 12 or 24 VDC

D - NO CLOSED - NO
COM @ 12/24VDC D Option
Door Status Sensor
COM
Magnetic Core Magnetic Core Locked Unlocked Locked
EN - NC OPEN - NC Connector Connector
12 or 24 VDC

1 Remove cover plate 1 Remove cover plate 2 2


Magnetic Core Magnetic Core Locked Unlocked Locked Unlocked
Connector Connector

1 Remove cover plate 2 2 3 Anti-tamper wiring

1 only required

EZ-A: ANTI-TAMPER
SWITCH - Modular Kit
Indicates cover plate removal
3 Anti-tamper wiring 3 Anti-tamper wiring 4 Replace cover plate 4 Replace cover plate

Place anti-tamper switch as shown.Place anti-tamper


3 Anti-tamper wiring 4 Replace cover plate Output:
4 Replace cover plate Cover depresses switch Cover depresses
SPDT Dry Contact, 3 Amp @ 12/24VDC
arm when mounted arm when mounte

Place anti-tamper switch as shown.Place anti-tamper switch as shown.


Com Cover depresses switch Com Cover depresses switch
No arm when mounted No arm when mounted
NC NC

Com Com
No No
NC NC

ti-tamper switch as shown.


presses switch
n mounted

www.sdcsecurity.com [email protected]
SECURITY DOOR
SECURITY CONTROLS
DOOR CONTROLS [t] 800.413.8783 805.494.0622 [f] 805.494.8861
8801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
2010 Security Door Controls Printed in the U.S.A. LIT-EZ Option Kit Upgrades 12.10
1 Remove cover plate screws.
EZ Option Upgrade Kits - Emlock 1512 / 1572

Specify 2 for 1512, 1572


EZ 1510W-2 Holding Force Upgrade
EZ 1570W-2 Energy Saver Upgrade
All 1511, 1512, 1513, 11571, 1572 and 1573 magnetic coils are field interchangeable without removing2 the lock from the frame. There is no reason
Remove cover plate screws.1 Remove cover plate screws. Remove 2 Remove
to remove and ship a lock for exchange. cover plate. cover plate.
Benefits of this interchangeability include: Applications
Distributors with limited stock may exchange coils to fulfill specific
EZ-1510W Holding Force Upgrade: Exchange 1200 lb coil with special sales needs, i.e. a 1570 with Dark Bronze finish may be
1650 lb holding force coil upgraded to a 1511 with dark bronze finish and visa versa.
EZ-1570W Energy Saver Upgrade: Save on power supply and
Installers may field upgrade to an Energy Saver where power supply
long term energy costs by exchanging 8.4 Watt,1650 lb coil
capacity is limited or upgrade to higher holding force where 1200 lbs
with 3 Watt, 1200 lb holding force coil
holding force proves inadequate, i.e. psychiatric or rehab center
Eliminate labor, shipping costs and time associated with special applications.
orders or complete lock removal and replacement.

ver plate screws.1 Remove cover plate2screws.


Remove 2 Remove 2 Remove 3 Lift input modules 3 Lift input modules
cover plate. cover plate. cover plate. and magnetic and magnetic

+ 34 56 78

+ 34 56 78
coils from coils from
ules 3 Lift input modules 4 Disconnect and 4 Disconnect and 5 the
Connect
case. the case.
and magnetic remore coils remore coils upgrade coils
+ 34 56 78

+ 34 56 78
+ 34 56 78

+ 34 56 78

+ 34 56 78
coils from
the case.

4 Disconnect and 5 Connect 5 Connect 6 Place magnetic coil 6 Place magnetic coil
remore coils upgrade coils upgrade coils firmly between core firmly between core
+ 34 56 78

+ 34 56 78

+ 34 56 78

lamination as shown. lamination as shown.

Connect
magnetic bond
sensor wires to the se
input module B
Option connector
5 Connect 6 Place magnetic coil 6 Place magnetic coil 6 Place magnetic coil 7 Place input modules asinput
7 Place shown.modules
ils upgrade coils firmly between core firmly between core firmly between core vertically between posts vertically between posts
+ 34 56 78

+ 34 56 78

lamination as shown. lamination as shown. lamination as shown. at each side of case. at each side of case.
odules 7 Place input modules 8 Input module wiring. 8 Input module wiring.
9 Attach cover plate.
ween posts vertically between posts
f case. at each side of case. B Option B Option
Connector Connector
+ 34 56 78

+ 34 56 78

LOCKED - NO LOCKED - NO
B Option B Option
Magnetic Bond Sensor COM Magnetic Bond Sensor COM
Connect UNLOCKED - NC Connect UNLOCKED - NC Connect
+ 34 56 78

+ 34 56 78

magnetic bond CLOSED - NO magnetic bond CLOSED - NO magnetic bond


D Option COM D Option COM PC Board
sensor wires to Sensor
Door Status the OPEN - NC
sensor wires to the
Door Status Sensor sensor wires to the
OPEN - NC
input module B input module B input module B Cradle Cradle
12 or 24 VDC 12 or 24 VDC Position Posts Position Posts
PC Board PC Board Option connector Option connector Option connector
as shown. as shown. as shown.
Cradle Cradle
Position Posts Position Posts Magnetic Core Magnetic Core
Connector Connector

8 Input module wiring.9 Attach cover plate. 9 Attach cover plate.

B Option
Connector

SECURITY DOOR CONTROLS


LOCKED - NO
B Option
Magnetic Bond Sensor COM
UNLOCKED - NC
CLOSED - NO
D Option COM
Door Status Sensor
OPEN - NC sdcsecurity.com [email protected]
12 or 24 VDC
sdcsecurity.com [email protected]

www.sdcsecurity.com [email protected]
SECURITY DOOR
SECURITY CONTROLS
DOOR CONTROLS [t] 800.413.8783 805.494.0622 [f] 805.494.8861
8801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
2010 Security Door Controls Printed in the U.S.A. LIT-EZ Option Kit Upgrades 12.10
EZ Option Upgrade Kits - Emlock 1581

EMLock EZ Kits
Field Upgradeable Option Modules
SDCs patented EMLock design represents the pinnacle of magnetic lock evolution. FIELD UPGRADE
The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Magnetic Bond Sensor
Door Status Sensors
Field Upgradeable by Distributors, Installers and Maintenance Staff Tamper
No need to ever remove a lock from the frame to upgrade or exchange
internal components.

11
Attach
Attach
door
door
status
status
module
module
to to
armature
armature 2 2Install
Install
lock
lock
per
per
installation
installation
instructions
instructions 3 3Inpu
In

EZ-D-80: DOOR Magne


Mag

POSITION SENSOR
Modular Kit
Indicates the door is open
and closed.

Application:
2 2Install
Install
lock
lock
per
per
installation
installation
instructions
instructions 3 3Input
Input
module
module wiring.
wiring. 4 4Annunciation
Annunciation
Door position status annunciation, 11 B Option
B Option
Remove
Removecover
cover
plate
plate 22 Place
Place
anti-tamper
anti-tamper
switch
switch
asas
shown
shown 3 3Anti
A
NO NO
Magnetic
Magnetic
Bond
Bond
Sensor
Sensor Position
Position
cover
cover
depresses
depresses
switch
switch
anti-tailgating, interlock, mantrap and COMCOM
arm
arm
when
whenmounted
mounted
communicating bathroom system
NOT
NOT
USED
USED
logic.
{{
NO NO

DPSDPS CO CO

Output: NC NC

SPDT Dry Contact, 250 mA @ 12/24VDC POWER


POWER

Locked
Locked Unlocked
Unlocked
Magnetic
Magnetic
Core
Core
Connector
Connector

22 Place
Place
anti-tamper
anti-tamperswitch
switch
asas
shown
shown 3 3Anti-tamper
Anti-tamperwiring
wiring 4 4Replace
Replace
cover
cover
plate
plate
Position
Position
cover
cover
depresses
depressesswitch
switch
arm
arm
when
whenmounted
mounted

ComCom
No No
NCNC

SECURITY DOOR CONTROLS


sdcsecurity.com [email protected]
sdcsecurity.com [email protected]

EZ-B-80 MAGNETIC BOND SENSOR


Modular Kit
While a Door Status Sensor indicates the door is open Application: Lock secure status annunciation,
or closed, SDCs Magnetic Bond Sensor provides higher mantrap system logic,
security monitoring by indicating the locked / unlocked CCTV camera activation.
mode, tampering and low holding force. The use of
both the door status and magnetic bond sensor is Output: SPDT Dry Contact,
recommended for high security applications. 250 mA @ 12/24VDC

1 1Remove cover
Remove plate
cover screws.
plate screws. 2 2Remove
Remove cover plate.
cover plate. 3 3Lift input
Lift inpu
1 1Remove
1Remove
Remove
cover
cover
cover
plate
plate
plate
screws.
screws.
screws. 2 2Remove
2Remove
Remove
cover
cover
cover
plate.
plate.
plate. 3 3Lift
3Lift
Lift
input
input
input
module
module
module 4 4Remove
4Remove
Remo 1
andandmagn
mag
and
and
and
magnetic
magnetic
magnetic
coil
coil
coil from
from
from
the
the
tc
from
fromthe c
the
from
from
from
the
the
the
case.
case.
case. bottom.
bottom.
bottom

+ 34 56

+ 34 56

+ 34 56
Place
Place
Place
the
th

+ 34 56 78

+ 34 56 78
Magnetic
Magneti
Magne

+ 34 56 78

+ 34 56 78

+ 34 56 78
Sensor
Sensor
Sensoat
base
base
base
ofofth
o
Magnetic
Magneti
Magne

Secure
Secure
Securse
ininplace
in
place
plac
w
screw
screw
screw
asa
shown.
shown.
shown

3 43Lift
Lift input
input
Remove 1 module
module
screw 57 7 4
54The Remove
Remove 1 Bond
screwSensor
1 screw 7 7Place 8 8Input mod
5 5The
5and
The
The
Magnetic
and Magnetic
Magnetic
Bond
Bond
magnetic
magnetic Bond
Sensor
coil
coil Sensor
Sensor
The
Place
Magnetic
7Place Magnetic
Place
input
from
from input
the input
the
Bond Sensor
module
module
module
case
case vertically
vertically
vertically
between
between
between
post
post
post 8 8Input input
8Place
Input
Input module
input
module
module
module vertically
module
wiring.
wiring.
wiring. between
vertically post
between post 9Input
9 9 Attach m
Attach
Attac
co
from the case should
should bebe
positioned
positioned asas at at
each side
each ofof
side case.
case.
should
should
should
from
from bebe
positioned
the
the be
positioned
positioned
case.
case. asasas atat
each
at
each
each
side
side
bottom.
bottom. side
ofofcase.
of
case.
case. BO
+ 34 56

+ 34 56

bottom. shown
shown below,
below,after step
after 4. 4.
step B Option
B Option
B Option Magnetic Bond
Magnetic BonS
+ 34 56

+ 34 56

+ 34 56
+ 34 56
+ 34 56

NONONO
shown
shown
shown
below,
below,
below,
after
after
after
step
step
step
4.4. 4. PCPC
Board
PC
Board
Board
Magnetic
Magnetic
Magnetic
BondPC
Bond Board
PC
Bond Board
Sensor
Sensor
Sensor
COM
COM
COM

Place the Place


Place thethe Cradle
Cradle
Cradle
Cradle
Cradle
Magnetic Bond Magnetic
Magnetic BondBond Position Posts
Position Posts

+ 34 56

+ 34 56
Position
Position
Position
Posts
Posts
Posts NOT
NOTUSED
NOT
USED
USED
Sensor
Sensor at at
thethe
+ 34 56

+ 34 56

+ 34 56

Sensor at the

{{ {
base of the base
base of of
thethe NONONO

Magnetic Core. Magnetic


Magnetic Core.
Core. DPS
DPS
DPS COCOCO

NCNCNC

Secure sensor Secure


Secure sensor
sensor P
in place with in in place
place with
with POWER
POWER
POWER

screw as screw
screw asas
shown. shown.
shown.
Magnetic
Magnetic
Magnetic
Core
Core
Core
Connector
Connector
Connector

st 8 98Input
Input module
module wiring.
wiring. 9 9Attach
Attach cover
cover plate.
plate.
Attach cover plate.
B Option
B Option
NO NO
Magnetic
Magnetic Bond
Bond Sensor
Sensor
COMCOM

NOT
NOT USED
USED

{{
NO NO

DPSDPS CO CO

NC NC

POWER
POWER

Magnetic
Magnetic Core
Core
Connector
Connector

www.sdcsecurity.com [email protected]
SECURITY DOOR
SECURITY CONTROLS
DOOR CONTROLS [t] 800.413.8783 805.494.0622 [f] 805.494.8861
8801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
2007 Security Door Controls Printed in the U.S.A. LIT-Datasheet date qty vendor
EZ Option Upgrade Kits - Emlock 1582

EMLock EZ Kits
Field Upgradeable Option Modules
SDCs patented EMLock design represents the pinnacle of magnetic lock evolution. FIELD UPGRADE
The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Magnetic Bond Sensor
Door Status Sensors
Field Upgradeable by Distributors, Installers and Maintenance Staff
No need to ever remove a lock from the frame to upgrade or exchange
internal components.

3 3Inpu
Specify 2 for 1582 11
Attach
Attach
door
door
status
status
module
module
to to
armature
armature 2 2Install
Install
lock
lock
per
per
installation
installation
instructions
instructions In

EZ-D-80: DOOR
POSITION SENSOR Door
Door
Sta

Modular Kit
12 o
1

Indicates the door is open


and closed.
Application:
2 2Install
Install
lock
lock
per
per
installation
installation
instructions
instructions 3 3Input
Input
module
module
wiring.
wiring. 4 4Annunciation
Annunciation
Door position status annunciation, 11 Remove
Removecover
cover
plate
plate 22 Place
Place
anti-tamper
anti-tamper
switch
switch
asas
shown
shown 3 3Anti
A
Position
Position
cover
cover
depresses
depresses
switch
switch
anti-tailgating, interlock, mantrap and arm
arm
when
whenmounted
mounted
NOT
NOT
USED
USED
communicating bathroom system CLOSED
CLOSED
- NO
- NO
logic. Door
Door
D Option
Status
D Option
Status
Sensor
Sensor
COMCOM
OPEN
OPEN- NC
- NC

Output: 12 or
12 24
or VDC
24 VDC

SPDT Dry Contact, 250 mA @ 12/24VDC


Magnetic
Magnetic
Core
Core
Connector
Connector
Locked
Locked Unlocked
Unlocked

22 Place
Place
anti-tamper
anti-tamperswitch
switch
asas
shown
shown 3 3Anti-tamper
Anti-tamperwiring
wiring 4 4Replace
Replace
cover
cover
plate
plate
Position
Position
cover
cover
depresses
depressesswitch
switch
arm
arm
when
whenmounted
mounted

ComCom
No No
NCNC

SECURITY DOOR CONTROLS


sdcsecurity.com [email protected]
sdcsecurity.com [email protected]

Specify 2 for 1582


EZ-B-80 MAGNETIC BOND SENSOR
Modular Kit
While a Door Status Sensor indicates the door is open Application: Lock secure status annunciation,
or closed, SDCs Magnetic1 Bond
RemoveSensor 1provides
cover plate screws. higher
Remove cover plate screws. mantrap system
2 Remove logic,
2 Remove cover plate.
cover plate.
security monitoring by indicating the locked / unlocked CCTV camera activation.
mode, tampering and low holding force. The use of
both the door status and magnetic bond sensor is Output: SPDT Dry Contact,
recommended for high security applications. 250 mA @ 12/24VDC

rews. 1 Remove
ove cover plate screws.cover plate screws. 2 Remove cover plate.
2 Remove cover plate.
2 Remove cover plate. 3 3 3

+ 34 56

+ 34 56

+ 34 56
3 4 Remove 1 screw 4 Remove 1 screw
from the case from the case
bottom. bottom.
Lift input module Lift input module L
Place the Place the and magnetic coil and magnetic coil a
Magnetic Bond Magnetic Bond from the case. from the case. f
Sensor at the Sensor at the
base of the base of the
+ 34 56
+ 34 56

Magnetic Core. Magnetic Core.


4 Remove 1 screw 5 The Magnetic Bond5 TheSensor should
Magnetic Bond Sensor should 6 Place input module
6 Place
vertically
inputbetween
module post
vertically between post
from the case Secure
be positioned as shown
be positioned Secure sensor
sensor as shown at each side of case.
at each side of case.
bottom.Lift input module Lift input after step 4.in
module
below, below, withstep 4.in place with
placeafter PC Board PC Board
and magnetic coil and magnetic coil screw as screw as
from the case.
Place the from the case. shown. shown. Cradle Cradle
Position Posts Position Posts
Magnetic Bond
Sensor at the
base of the
++ 3344 5566

++ 3344 5566

Magnetic Core.
Magnetic
sor should 5 The
Bond Sensor
Magnetic
should 6 Place input module
Bond Sensor should 6 Place
vertically
inputbetween6 Place
module vertically
post inputbetween
module vertically
post 7 Input
between module wiring.
post 7 Input module wiring. 7 Input module wiring.
Secure
ositioned as shown
be sensoras shown
positioned at each side of case.
at each side of case.
at each side of case. NO - SPST NO - SPST NO - SPST
+ 34 56 78

+ 34 56 78
in place with
w, after step 4.below, after step 4.
B Option B Option B Option
PC Board PC Board PC Board Magnetic Bond Sensor Magnetic Bond Sensor Magnetic Bond Sensor
screw as
shown. Cradle Cradle Cradle
Position Posts Position Posts Position Posts
NOT USED NOT USED NOT USED
CLOSED - NO CLOSED - NO CLOSED - NO
D Option D Option D Option
++ 3344 5566

++ 3344 5566

COM COM COM


7 Input module wiring.
module wiring. 8 Attach cover plate.
8 Attach cover plate. Door Status Sensor Door Status Sensor Door Status Sensor
OPEN - NC OPEN - NC OPEN - NC
NO - SPST NO - SPST
B Option B Option
tic Bond Sensor Magnetic Bond Sensor 12 or 24 VDC 12 or 24 VDC 12 or 24 VDC
+ 34 56 78

+ 34 56 78

+ 34 56 78

NOT USED NOT USED Magnetic Core Magnetic Core


Connector Connector
CLOSED - NO CLOSED - NO
D Option D Option
COM COM
atus Sensor Door Status Sensor
OPEN - NC OPEN - NC
8 Attach cover plate.
r 24 VDC 12 or 24 VDC

Magnetic Core Magnetic Core


Connector Connector

www.sdcsecurity.com [email protected]
SECURITY DOOR
SECURITY CONTROLS
DOOR CONTROLS [t] 800.413.8783 805.494.0622 [f] 805.494.8861
8801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
2007 Security Door Controls Printed in the U.S.A. LIT-Datasheet date qty vendor