0% found this document useful (0 votes)
51 views

RHM 60 - Coriolis Mass Flowmeter For Medium FL Ow Also Suited For High Pressure Applications

The RHM 60 mass flowmeter is designed for medium flow rates up to 180 t/hr and high pressure applications up to 200 bar. It uses a patented torsion swinger design which provides highly accurate measurements independent of pressure even at low flow velocities. The meter has excellent performance and reliability in applications involving medium flow rates combined with high operating pressures. It offers high accuracy, repeatability, stability, and minimal maintenance needs for critical industrial processes.

Uploaded by

Teknik Gresik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views

RHM 60 - Coriolis Mass Flowmeter For Medium FL Ow Also Suited For High Pressure Applications

The RHM 60 mass flowmeter is designed for medium flow rates up to 180 t/hr and high pressure applications up to 200 bar. It uses a patented torsion swinger design which provides highly accurate measurements independent of pressure even at low flow velocities. The meter has excellent performance and reliability in applications involving medium flow rates combined with high operating pressures. It offers high accuracy, repeatability, stability, and minimal maintenance needs for critical industrial processes.

Uploaded by

Teknik Gresik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

RHM 60 - Coriolis Mass

Flowmeter for medium flow


also suited for high pressure applications
The RHM 60 can measure flow rates up to 180 t/hr with the patented Omega shape meter technology,
manufactured by Rheonik, the mass flowmeter experts.

APPLICATIONS
Loading of boats, vessels, rail tank
wagons
High temperatures and other challenging
applications
Highly viscous media (low pressure drop
and excellent performance at low flow
conditions)

FEATURES
As heavy duty version available
(increased wall thickness of measuring
pipes for additional safety - 200 bar)
Flow Accuracy of 0.1%
Repeatability better than 0.05%
Patented torsion swinger
Customer adaptations possible for
application optimized solutions
Typical measuring ranges from
30 to 3000 kg/min
EEx Approvals (i.e. ATEX, CSA, ...)
Custody Transfer Approvals (i.e. PTB, NMI, ...)

ADVANTAGES
GENERAL Medium flow rates in combination with high
The RHM 60 has been designed for medium flow rates operating pressure
and tough application conditions. Due to the optional Patented torsion swinger design assures most
heavy duty measuring pipes (up to 250 bar), this meter stable and drift free measurement
becomes the first choice in many applications which
have medium flow rates with high operating presssure.
Increased signal to noise ratio by torsion
swinger
This unique design, which offers excellent performance Longest life time and increased safety (low
and reliability, has created the most satisfied customers stress in welds and increased wall thickness
worlwide. Unlike other mass flowmeter manufacturers,
against abrasion)
Rheonik uses a patented torsion rod swinger with
the Omega shape and support bars which results in No moving parts, practically no maintenance
high accuracy measurement, which is independent of
pressure, even at very low flow velocities. The meter
also has extremely good repeatability and high stability
for critical applications.

www.rheonik.com - the mass flowmeter experts

Rheonik reserves all rights for changes without notice


M60 Page 1 of 6 / 18 November 2005 - v5
PERFORMANCE RHM 60
Max Flow 3000 kg/min (6610 lb/min)
1) Standard Models

in in error in % Typical P in bar (psi)


Rates / turndown ratio
kg/min lb/min of reading 1 cP 100 cP 1000 cP
nominal rate Qnom 2500 5512 0.20 0.6 (8.3) 1.2 (18.3) 3.9 (56)
0.2 * Qmax (5:1) 600 1320 0.20 ~ 0 (0.6) 0.1 (1.4) 0.9 (13)
0.1 * Qmax (10:1) 300 661 0.20 ~ 0 (0.1) ~ 0.1 (0.7) 0.5 (6)
0.05 * Qmax (20:1) 150 330 0.20 ~ 0 (0) ~ 0 (0.3) 0.2 (3)
0.02 * Qmax (50:1) 60 132 0.50 ~ 0 (0) ~ 0 (0.1) ~ 0.1 (1)

2) Optimized Low Flow Models


(*)
/ optimized to be operated between 0.0135 x Qmax and 0.27 x Qmax

0.27 * Qmax (1:1) 800 1763 0.12 ~ 0.1 (1.0) ~ 0.2 (2.0) 1.2 (17)
0.027 * Qmax (10:1) 80 176 0.15 ~ 0 (0) ~ 0 (0.2) 0.1 (2)
(**)
0.0135 * Qmax (20:1) 40 88 ~ 0.50 ~ 0 (0) ~ 0 (0.1) ~ 0.1 (1)
(*)
serial/single path version offers the same accuracy at half the flow (Qmax = 1500 kg/min)
(**)
around 0.30 - 0.70 % accuracy depending on the installation conditions

3) Gold Line Models / application fine tuned meters

1 * Qnom (1:1) 2500 5512 0.10 0.6 (8.3) 1.2 (18.3) 3.9 (56)
0.2 * Qnom (5:1) 500 1102 0.12 ~ 0 (0.4) ~ 0.1 (1.2) 0.8 (11)
0.1 * Qnom (10:1) 250 551 0.15 ~ 0 (0.1) ~ 0 (0.6) 0.4 (5)

Repeatability better 0.05% of rate


Density better than 0.0015 g/cc - Gold Line: Field adjustable to better 0.001 g/cc
Temperature better 1C

Standard Models Gold Line Models

Error (%) P (bar) Error (%) P (bar)


1,5 1,0 1,5 1,0

1 1

0,5 0,5

0 0,5 0 0,5

-0,5 -0,5

-1 -1

-1,5 0,0 -1,5 0,0


0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500
Flow rate (kg/min) Flow rate (kg/min)

For serial (single pipe/path) sanitary design Qmax is 1500 kg/min (50%). Data above refer to standard wall thickness.
Error of reading (including zero drift) indications refer to reference conditions H2O, 18-24C (66-76F), 1-3 bar (15-45 psi).
RHM sensor do not suffer from pressure effect due to torsional oscillation and semi circle (non-deforming) measurement section.
Temperature changes of +/- 25C around the operating point are negligible.
Pressure drop refers to Newton liquids, with parallel measuring loops and block/manifold connection.
Nominal flow refers to approx. 10 m/s (33 ft/sec) velocity in measuring loops for best performance.
Calibration to customer range, with increased accuracy, possible.

www.rheonik.com - the mass flowmeter experts

Rheonik reserves all rights for changes without notice


M60 Page 2 of 6 / 18 November 2005 - v5
GENERAL DIMENSIONS RHM 60
Type II (sealless welded parallel measuring loops w/o seallings [PF0])

A1 = 910 mm (35.83")
A2 = 950 mm (37.40")
B1 = 150 mm (5.91")
B2 = 230 mm (9.06")
H1 = 1253 mm (49.33")
H2 = 1443 mm (56.81")
E = 300 mm (11.81")
W = 150 mm (5.91")

Weight:
approx. 200 kg (440 lb)

Shipping box:
approx. 180 x 120 x 75 cm
(71 x 48 x 30 inch)

Process Connection Face to face length (L)(*) Order Code


4" CL 150 acc. ANSI B16.5 725 mm (28.54") F1
4" CL 300 acc. ANSI B16.5 725 mm (28.54") F2
Standard 4" CL 600 acc. ANSI B16.5 725 mm (28.54") F3
DN100 / PN40 acc. DIN 2527 - C 725 mm (28.54") C1
DN100 / PN100 acc. DIN 2527 - E 725 mm (28.54") C2
4" CL 900 acc. ANSI B16.5 900 mm (35.43") A9
Optional 4" CL 1500 acc. ANSI B16.5 900 mm (35.43") XX
DN100 / PN160 acc. DIN 2527 - E 900 mm (35.43") D3
DN100 / PN250 acc. DIN 2527 - E 900 mm (35.43") XX
Special
Different sized flanges please consult factory XX
(*)
Customization possible on request.
The finish type of our ANSI flanges is RF/SF (AARH 125-250 (inch) - Ra 3,2 up to 6,3 (m)). Others available on request.
Above table only shows our general process fittings.
For further customization with regard to special fittings and face to face length please contact your local agent.

www.rheonik.com - the mass flowmeter experts

Rheonik reserves all rights for changes without notice


M60 Page 3 of 6 / 18 November 2005 - v5
GENERAL DIMENSIONS RHM 60
Type III (sealless welded serial measuring loops w/o seallings [SF0])

A1 = 910 mm (35.83")
A2 = 950 mm (37.40")
B1 = 150 mm (5.91")
B2 = 230 mm (9.06")
H1 = 1250 mm (49.21")
H2 = 1385 mm (54.53")
E = 300 mm (11.81")
W = 150 mm (5.91")
V = 96 mm (3.78")

Weight:
approx. 200 kg (440 lb)

Shipping box:
approx. 180 x 120 x 75 cm
(71 x 48 x 30 inch)

Process Connection Face to face length (L)(*) Order Code


Sanitary 2" Tri Clamp acc. DIN 32676 500 mm (19.68") S1
Fittings (**) DN50 / Sanitary acc. DIN 11851 400 mm (15.74") S2
3" CL 150 acc. ANSI B16.5 400 mm (15.75") A1
Flange 3" CL 300 acc. ANSI B16.5 400 mm (15.75") A2
Other
Fittings DN80 / PN40 acc. DIN 2527 - C 400 mm (15.75") D1
Different sized flanges please consult factory XX

(*)
Customization possible on request.
(**)
Fitting material is 1.4435 / SS 316L.
The finish type of our ANSI flanges is RF/SF (AARH 125-250 (inch) - Ra 3,2 up to 6,3 (m)). Others available on request.
Above table only shows our general process fittings.
For further customization with regard to special fittings and face to face length please contact your local agent.

www.rheonik.com - the mass flowmeter experts

Rheonik reserves all rights for changes without notice


M60 Page 4 of 6 / 18 November 2005 - v5
GENERAL SPECIFICATIONS RHM 60

Approvals Pressure rating


ATEX (CESI 02 ATEX 053 X): Pressured part of the meter consists of the
Ex II 1 G, EEx ia IIC T6-T1 measuring loops and the connection part.
CSA (220705) The weaker of both parts decides the maximum
Class I, Div 1 and 2, allowed operating pressure.
Groups A, B, C and D;Type 3 Below is the max. operating pressure of the
measuring loops(*).
Custody Transfer Approvals
(PTB 1.32-97027224 and NMI TC 3382) (*) These values are only valid for SS 316Ti & SS 904L materials.
Statements for others materials on request.
PED according to directive 97/23/EC
available Standard version:
3A Sanitary Approvals 100 bar @ 120C (1450 psi @ 248F)
90 bar @ 210C (1305 psi @ 410F)
Electrical connection 80 bar @ 350C (1160 psi @ 662F)
Junction box / aluminium coated (standard) wall thickness is generally 2.9 mm (0.11")
IP 65 (Nema 4X)
(Junction box in SS optional) Optional high pressure version:
Cable entry M25 x 1.5 200 bar @ 120C (2900 psi @ 248F)
(M20 x 1.5, " and " NPT optional) wall thickness is generally 5.5 mm (0.21")
Max cable length between RHM and RHE:
100 m (330 ft)
Other pressure version
- on request -
200 m (660 ft) only with factory approval

Housing Temperature rating


Stainless Steel: 1.4301 / SS 304 NT Models from -20 to +120C (-4 to +248F)
- others on request - ET Models from -45 to +120C (-49 to +248F)
Protection class: IP 65 (Nema 4X) ET1 Models from -200 to +50C (-328 to +122F)
- higher on request - ET2 Models from -45 to +210C (-49 to +410C)
HT Models from 0 to +350C (+32 to +662F)
Material of wetted parts
1.4571 / SS 316Ti (standard)
1.4539 / SS 904L on request
Hastelloy C22 on request
Other material on request

For further information


please contact your
local representative

- to be continued with the order code on the next page -

www.rheonik.com - the mass flowmeter experts

Rheonik reserves all rights for changes without notice


M60 Page 5 of 6 / 18 November 2005 - v5
ORDER CODE RHM 60
Order Code Structure
The order code of the Rheonik Sensors consists of 6 sections (see previous pages / below).
Restrictions of combinations may apply. For specials, please comment your needs in plain text / sketches.

Temperature Rating
T1 NT Models (Normal Temperature Models) from -20 to +120C (-4 to +248F)
TA ET Models (Extended Temperature Models) from -45 to +120C (-49 to +248F)
T2 ET2 Models (Extended Temperature Models) from -45 to +210C (-49 to +410F)
T3 ET1 Models (Extended Temperature Models) from -200 to +50C (-328 to +122F)
T4 HT Models (High Temperature Models) from 0 to +350C (+32 to +662F)

Pressure Rating
P1 Standard pressure version (100 bar @ 120C / 1450 psi @ 248F) - page 5 -
P2 High pressure version (200 bar 120C / 2900 psi @ 248F) - page 5 -
PX Other pressure version (on request) - page 5 -

Construction Type
PF0 Parallel Measuring Loops Seal Less Welded Version - page 3 -
SF0 Serial Measuring Loops Seal Less Welded Version / Single Path - page 4 -
XXX Other construction type on request

Material of Wetted Parts


M1 1.4571 / SS 316Ti
M2 1.4539 / SS 904L
M3 Hastelloy C22

Process Connection
XX Code available on pages 3 and 4.

Hazardous Area Approvals


NN Without Ex Approvals
AT ATEX Approvals (CESI 02 ATEX 053 X) - Ex II 1 G, EEx ia IIC T6-T1
CS CSA Approvals (220705) - Class 1, Div 1 / Group A, B, C, and D; Type 3

Order Code Example


M#60 T1 P1 PF0 M1 A1 AT
T1: NT (Normal Temperature Models) from -20 to +120C (-49 to +248F)
P1: Standard pressure version (100 bar @ 120C / 1450 psi @ 248F)
PF0: Parallel Measuring Loops Seal Less Welded Version
M1: 1.4571 / SS 316 Ti
A1: 4" CL 150 acc. ANSI B 16.5
AT: ATEX Approvals (CESI 02 ATEX 053 X)

M#60 __ __ ___ __ __ __

www.rheonik.com - the mass flowmeter experts

Rheonik reserves all rights for changes without notice


M60 Page 6 of 6 / 18 November 2005 - v5