SERIES P2
MOBILE PISTON PUMP
Clockwise rotation (right) - side ported pump Counter clockwise rotation (left)-side ported pump
Clockwise rotation (right) - rear ported pump Counter clockwise rotation (left)-rear ported pump
P2060* and P2075* only P2060* and P2075* only
Minimum pump inlet pressure under static and dynamic load : pin min = 0,8 bar absolute
pressure port
pressure
drain port gauge port
suction optional
suction port drain port
gauge port
OPTION !
Connect highest drain port with a separate line
reduced in size for purging the air out of the
case
AND
WARNING !
Do not combine drain lines.
pcase = 2 bar
WARNING !
Do not restrict drain line.
Prior to start up, the pump case must be filled with hydraulic fluid (use case drain port).
Initial start up should be at zero pressure with an open circuit to enable the pump to prime.
Pressure should only be increased once the pump has been fully primed.
6. Hydraulic Fluid
Remark :
Maximum system pressure reduced to 210 bar for water based fluids.
Bearing life time reduced to 25 % by using water based fluids.
7. Temperature
7.1. Check hydraulic fluid specification for chemical resistance of seal material !
Remark :
The highest fluid temperature will be at the drain port of the pump,
up to 20C higher than in the reservoir.