100% found this document useful (4 votes)
1K views

Piles Design Calc PDF

1. The document presents calculations for the structural capacity of piles at the Rochor Station project. 2. It analyzes piles of different diameters (800mm, 1000mm) and reinforcement configurations under various compression and tension loads. 3. For each pile, it checks that the percentage of reinforcement, structural capacity in compression and tension, and crack width under tension are all within acceptable limits according to relevant design codes.

Uploaded by

Mukhlish Akhatar
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (4 votes)
1K views

Piles Design Calc PDF

1. The document presents calculations for the structural capacity of piles at the Rochor Station project. 2. It analyzes piles of different diameters (800mm, 1000mm) and reinforcement configurations under various compression and tension loads. 3. For each pile, it checks that the percentage of reinforcement, structural capacity in compression and tension, and crack width under tension are all within acceptable limits according to relevant design codes.

Uploaded by

Mukhlish Akhatar
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 1
REF CPD-01 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3100 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.9 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 2
REF CPD-02 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 2850 kN


Max Ten Force Ft = 500 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 3.15 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00088

m = 0.00029
Wcr = 0.1 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 3
REF CPD-03 Dwg Reference: OUTPUT

Diameter of Pile D = 1000 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 194 mm
Percentage Rebar 0.52 %
Rebar provided = 13 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 5500 kN


Max Ten Force Ft = 250 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 4085.71 mm2


Ac = 781629 mm2
Fs = 2.53 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 1071.27 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 194 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 106 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00031

m = -0.00033
Wcr = -0.11 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 4
REF CPD-04 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 2750 kN


Max Ten Force Ft = 500 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 3.26 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00088

m = 0.00029
Wcr = 0.100 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 5
REF CPD-05 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3400 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.64 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 6
REF CPD-06 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 4400 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.04 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 7
REF CPD-07 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 190 mm
Percentage Rebar 0.63 %
Rebar provided = 10 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 4250 kN


Max Ten Force Ft = 750 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.63 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 3142.86 mm2


Ac = 499714 mm2
Fs = 2.14 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 824.057 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 190 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 104 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00119

m = 0.00066
Wcr = 0.21 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 8
REF CPD-08 Dwg Reference: OUTPUT

Diameter of Pile D = 1000 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 207 mm
Percentage Rebar 1.24 %
Rebar provided = 12 T 32

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 7850 kN


Max Ten Force Ft = 300 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 1.24 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 9654.86 mm2


Ac = 776059 mm2
Fs = 2.01 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 2531.5 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 207 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 109 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00016

m = -0.00011
Wcr = -0.04 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 9
REF CPD-09 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3300 kN


Max Ten Force Ft = 600 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.72 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00106

m = 0.00047
Wcr = 0.16 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 10
REF CPD-10 Dwg Reference: OUTPUT

Diameter of Pile D = 1000 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 194 mm
Percentage Rebar 0.52 %
Rebar provided = 13 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 6050 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 4085.71 mm2


Ac = 781629 mm2
Fs = 2.30 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 1071.27 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 194 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 106 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00064
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 11
REF CPD-11 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3000 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.99 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 12
REF CPD-12 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 2850 kN


Max Ten Force Ft = 500 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 3.15 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00088

m = 0.00029
Wcr = 0.1 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 13
REF CPD-13 Dwg Reference: OUTPUT

Diameter of Pile D = 1000 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 194 mm
Percentage Rebar 0.52 %
Rebar provided = 13 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 5450 kN


Max Ten Force Ft = 200 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 4085.71 mm2


Ac = 781629 mm2
Fs = 2.55 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 1071.27 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 194 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 106 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00024

m = -0.00039
Wcr = -0.12 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 14
REF CPD-14 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 2700 kN


Max Ten Force Ft = 450 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 3.32 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.0008

m = 0.00021
Wcr = 0.07 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 15
REF CPD-15 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3500 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.56 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !