0% found this document useful (0 votes)
458 views

Moment Connection

The moment connection between a beam and embedded plate in a parking garage is designed to resist critical forces from structural analysis. Calculations follow AISC 360-10 and ASCE 7-10 standards. Shear is resisted by 3 bolts which are checked for shear and bearing capacity. Bolts also provide slip resistance. Block shear capacity of the joint is sufficient. A fillet weld between the angle and plate transfers shear loads with adequate strength. Moment effects are resisted through tension and compression in a couple formed by a plate welded to the embedded plate, which is also checked to have sufficient capacity. All components meet strength requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
458 views

Moment Connection

The moment connection between a beam and embedded plate in a parking garage is designed to resist critical forces from structural analysis. Calculations follow AISC 360-10 and ASCE 7-10 standards. Shear is resisted by 3 bolts which are checked for shear and bearing capacity. Bolts also provide slip resistance. Block shear capacity of the joint is sufficient. A fillet weld between the angle and plate transfers shear loads with adequate strength. Moment effects are resisted through tension and compression in a couple formed by a plate welded to the embedded plate, which is also checked to have sufficient capacity. All components meet strength requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Design of the Moment Connection

PCJC Parking Facility


Units: kips lb 1000

Design Calculations

The moment connection between the beam and embed plate is designed for the maximum ciritcal forces
obtained analysis.
Calculations conform to AISC 360-10 and ASCE 7-10

Following figure shows the forces acting in the moment connection.

1. Material Properties:

Design strength factor: 0.75 Table J2.5, AISC 360-10

Allowable strength factor: con 2.0 Table J2.5, AISC 360-10

Beam W14 x 22 & Angles L 3/8 x 3 x 3 1/2

Yield strength of the material: fy 36ksi

Ultimate tensile strength of the material: fu 58ksi

DesignCalculations:Moment 1 of 7
2. Loads in the connection:

Shear force in the connection: Fsh 9kip

Moment at the support: M sup 34kip ft


Load factor f 1.6

3. Shear Connection:

The shear forces are transfered from web of the beam to the embed plate thro bolts and angles welded.

Check for Bolts:


3
Nominal Diameter of the bolt: d n in
4
Nominal area of the bolt: 2 1 2
Ab d n Ab 0.442 in
4

Grade of the bolt: Grade "ASTM A325-N"

Number of bolts: n b 3

Shear

Nominal Shear strength Rn.bolt 48ksi

Maximum allowable shear force in the bolts: Fb.allw Rn.bolt Ab Fb.allw 15.904 kip

Fsh f
Maximum Shear force in each bolt: Fb.max Fb.max 4.8 kip
nb
Fb.max
Maximum utilisation of bolt against shear: URbolt URbolt 0.302
Fb.allw
< 1.0, Hence O.K.

DesignCalculations:Moment 2 of 7
Bearing Strength at Bolt holes

Specified minimum Tensile


strength of the connected fu 58 ksi
material:
3
Clear Distance, Lc in
4
3
tcon in
Thickness of the connected material: 8

Bearing strength
around the bolt hole:
Rn.br if 1.2 Lc tcon fu 2.4 d n tcon fu 1.2 Lc tcon fu 2.4 d n tcon fu

Rn.br 19.575 kip
Fb.max
Maximum Utilisation against bearing: URBolt.bear URBolt.bear 0.245
Rn.br

< 1.0, Hence O.K.

Shear strength of the slip critical connections:

Required strength factor: slip 0.85

Mean slip coefficient: slip 0.3 class A surface considered

Multiplier factor: Du 1.13

hole factor: h sc 0.85 short-slotted holes considered

number of slip planes: Ns 2

Minimum bolt tension Tb 28kip Table J3.1

Design Slip resistance: Rn.slip slip slip Du h sc Ns Tb Rn.slip 13.7 kip

Maximum utilisation of bolt Fb.max


URslip
against shear with slip critical Rn.slip URslip 0.35
connection :
< 1.0, Hence O.K.

DesignCalculations:Moment 3 of 7
Block Shear strength

Rn.blk min0.6 fu 8.5in 3 in in 0.6 fy ( 8.5in) in


13 1 1
Block shear strength of the joint:
16 2 2

Rn.blk 91.8 kip

Maximum utilisation of block Fsh f


URslip
shear resistance : Rn.blk URslip 0.209

< 1.0, Hence O.K.

Weld check between Angle and embed plate

Following type of weld is used (special case) for calculating the strength of the weld.

1
Size of the weld: aw in
4

Design strength factor: 0.9

Strength of the Weld material - E70 electrode: FEXX 70ksi

DesignCalculations:Moment 4 of 7
Length of the weld: Lw 8.5in

Eccentric distance from the load to weld: ex 2.5in

ex
Parameter a 0.294
Lw

For k = 0, corresponding C value is: Cw 2.32


aw
Strength of the weld: Rn Cw Lw kip Rn 78.88 kip
1
in in
16

Fsh f
Utilisation ratio of the weld: URw.sh URw.sh 0.183
Rn

Maximum utilisation in the bolt


connection for shear force
UR1 max URslip URBolt.bear URbolt URw.sh
transfer
UR1 0.302

< 1.0, Hence O.K.

4. Moment Connection:

3
Lever Arm d 13.7in 2 in d 14.45 in
8
Design moment: M des M sup f M des 54.4 kip ft

DesignCalculations:Moment 5 of 7
Moment is replaced by couple:
M des
Maximum Tension / Compression force: Fcouple Fcouple 45.176 kip
d
For the above force the welds and plate 3/8 x 4 x 8 is checked.

Weld check between plate and embed plate

1
Size of the weld: aw in
4

Design strength factor: 0.8

Strength of the Weld material - E70 electrode: FEXX 70ksi

Length of the weld: Lw 6in

Total shear force in the weld: Ftot.1 Fcouple Ftot.1 45.176 kip

kip
Strength of the weld: Rn 1.392 4 Lw 2 Rn 66.816 kip
in
Ftot.1
Utilisation ratio of the weld: URL.w URL.w 0.676
Rn
< 1.0, Hence O.K.

DesignCalculations:Moment 6 of 7
Check for Tension / Compression capacity of the plate

Design strength factor: 0.9

3 2
Sectional Area of the plate: Aplate 4in in Aplate 1.5 in
8

Axial load capacity of the plate: Rn.pl fy Aplate Rn.pl 48.6 kip

Ftot.1
Utilisation ratio of the plate: URplate URplate 0.93
Rn.pl
< 1.0, Hence O.K.

Maximum utilisation in the


Moment connection
UR2 max URL.w URplate UR2 0.93

< 1.0, Hence O.K.


Maximum utilisation in the
Calculation
URmax max UR1 UR2 URmax 0.93

< 1.0, Hence O.K.

DesignCalculations:Moment 7 of 7

You might also like