Grandview
Grandview
1 Revision #:
SCALE @ 24" X 36"
DATE: 2.20.2017
GRANDVIEW
RENDERING
FOR ILLUSTRATION ONLY
2016
208.292.3400
THE CONTRACTOR SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. LEGAL: LOT 7, BLK 1 2ND FLOOR PLAN &
CHIEF ARCHITECT, INC. MAKES NO WARRANTY WHATSOEVER WITH REGARD TO ITS SAMPLE DRAWINGS SOLELY
WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. WOODLAND HEIGHTS SEVENTH ADDITION STAIR SECTION/DETAIL
FOR DEMONSTRATIVE AND ILLUSTRATIVE PURPOSES. CHIEF ARCHITECT, INC MAKES NO WARRANTY THAT THE 5
DIMENSIONS IN THESE SAMPLE DRAWINGS ARE ACCURATE AND FREE OF DISCREPANCIES. CHIEF ARCHITECT, ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. CONTRACTOR FOUNDATION PLAN 6
INC MAKES NO WARRANTY THAT THESE SAMPLE DRAWINGS COMPLY WITH ANY BUILDING CODES. THESE SHALL BE RESPONSIBLE AND BEAR ANY FINES OR PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING FIRE DISTRICT KOOTENAI FIRE & RESCUE FRONT ELEVATIONS 7
SAMPLE DRAWINGS ARE PROVIDED TO YOU "AS IS," AND CHIEF ARCHITECT, INC. AND THE LICENSORS OF SECTIONS & DETAILS 8
PROCESS VIOLATIONS. INSURANCES SHALL BE IN FORCE THROUGHOUT THE DURATION OF THE BUILDING PROJECT. WATER: NORTH KOOTENAI WATER
THESE SAMPLE DRAWINGS DISCLAIM ANY AND ALL WARRANTIES WITH RESPECT TO THESE SAMPLE DRAWINGS, SECTIONS & DETAILS 9
SEWER: HAYDEN LAKE RECREATIONAL SEWER
WHETHER EXPRESS OR IMPLIED OR ARISING BY CUSTOM OR TRADE USAGE, AND, SPECIFICALLY, MAKE NO SHEAR WALL LOCATIONS 10
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. WALL FRAMING 11
THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE STORM WATER PERMIT: _____ FLOOR FRAMING 12
UNDER NO CIRCUMSTANCES WILL CHIEF ARCHITECT, INC, ITS RESELLERS, ITS DISTRIBUTORS OR THE ROOF PLAN 13
DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE BLDG PERMIT: _____
LICENSORS OF THE SAMPLE DRAWINGS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING FROM TORT OR DOOR & WINDOW SCHEDULE 14
CONTRACT, INCLUDING LOSS OF DATA, LOST PROFITS, COST OF COVER, OR OTHER SPECIAL, INCIDENTAL, INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING INTERIOR SECTIONS &
CONSEQUENTIAL OR INDIRECT DAMAGES ARISING OUT OF THE USE OF THESE SAMPLE DRAWINGS. PLEASE ROUGH OPENINGS). DESIGNER: CHIEF ARCHITECT ELEVATIONS 15
ELECTRICAL PLAN 16
REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS ALL TRADES SHALL MAINTAIN A CLEAN WORK SITE AT THE END OF EACH WORK DAY. DESIGN CONSULTANT: H2A ARCHITECTS
PLUMBING &
AND CONDITIONS PURSUANT TO THESE BUILDER: YOUNG CONSTRUCTION
HVAC PLAN 17
PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. SITE DISTURBANCE: CLEARWATER SUMMIT MSTR BATH PLAN & ELEVATIONS 18
KITCHEN PLAN & ELEVATIONS 19
ENGINEERING: BC ENGINEERS
PROJECT STATISTICS: PROJECT NARRATIVE
SHEET NUMBER
LOT SIZE: 21,170 SF (.486 ACRE) THE PROPOSED SITE LOCATION IS 1910 E Grandview Drive- COEUR D'ALENE, ID. - KOOTENAI COUNTY, IDAHO. Lot 7, Block 1 Woodland
2
130 131 132 133
118.65 ft 136 Heights 7th Addition. THE PROPOSED PROJECT INCLUDES A SINGLE-FAMILY RESIDENCE, BOULDER RETAINING WALLS, PAVED
Revision #:
ANTICIPATED DISTURBED AREA: 6,995 SF 135
129 DRIVEWAY, AND OTHER LANDSCAPE FEATURES. BOULDER RETAINING WALLS, ON PLAN, THAT EXCEED 4' HEIGHT SHALL BE
BLDG. ENVELOPE: 3,970 SF
ROOF: 5,475 SF LOT 7 N28 29' 35"W EXISTING
ENGINEERED. STORM WATER RUNOFF FROM DRIVEWAY SHALL BE DIRECTED TO THE EXISTING ROADSIDE SWALE/ CULVERT VIA
THE PROPOSED FRENCH DRAIN SYSTEM ADJACENT TO THE EDGE OF THE DRIVEWAY. STORM WATER RUNOFF FROM HOUSE
FRONT/REAR HEIGHT: 25.8' BLOCK 18 134 FENCE
136
SHALL BE DISPERSED WITHIN ADJACENT LANDSCAPE AREAS. ALL GRADES SHALL HAVE A POSITIVE DRAINAGE AWAY FROM
LIVABLE SF: 3,587 22" DIA UNDISTURBED NATIVE FOUNDATION. COBBLE ROCKERY AT DOWNSPOUTS AND/ OR AREAS WHERE THERE IS SHEET FLOW OFF ROOF SHALL BE
128 INSTALLED TO CONTROL EROSION. A SEDIMENT CONTROL SILT FENCE SHALL BE INSTALLED AND INSPECTED PER LOCATION ON
VEGETATION
25'
MAIN: 3,000 PLAN PRIOR TO DISTURBANCE OF THE SITE. ALL DISTURBED AREAS SHALL REVEGETATED WITH ORNAMENTAL PLANTS, NATIVE
DATE: 2.20.2017
69'-11"
126 130 FOR THE MAINTENANCE OF THE SILT FENCE TO ASSURE CONTINUED PERFORMANCE OF IT'S INTENDED USE. AT MINIMUM TWO
TIME OF EXCAVATION. 132
129 INSPECTIONS BY THE DESIGN PROFESSIONAL ARE REQUIRED FOR THE PROPOSED PROPERTY. 1) AFTER SEDIMENT CONTROL SILT
EXIS
2' T 12
PLAN
EXISTING UTILITIES. ALL FINISH GRADES SHALL BE 12 2' T H
123 OW 115.5' T OW 122
ON E
ST SID CL
OT
TING
SMOOTH AND UNIFORM 6 'B OW 116
PO HILL
N FIL T ER
L
11 LAWN ' BO D OW
UP
HIL
FL O W N DL
INE
111.5' BOW OU
RET
MARKED TREES SHALL BE REMOVED PRIOR TO
W GR SIDE SECTION
18" DIA / 34'
AI
122
SITE WORK. 115 STAIR BURY BOTTOM EDGE
NING
N49 5
121 STAKE DRIVEN OF CLOTH 6"
154.67
CALL BEFORE YOU DIG: 800.428.4950 LAWN
WAL
155.83 ft
PROPOSED
WATER
SILT FENCE
SILT FENCE DETAIL
NOT TO SCALE
DETAIL
L
NOT TO SCALE
9' 11"E
FEATURE 122
PATIO 112'
ft
2-4" ROUND
14'-9" 112 DRAIN ROCK
120
121
FL O W
119
10
"
DISTURBED AREAS SHALL
BE REVEGETATED W/ GRASS 19'-2" PROPOSED BOULDER
GRANDVIEW
118 12" DIA 118 4" PERFORATED
11
OW
117 11 OW
113 GARAGE BE REVEGETATED W/ 2'
T TELEPHONE/CABLE POA BO FRENCH
FRENCH DRAIN DETAILDETAIL
DRAIN
115
NOT TO SCALE
116
PLANT MATERIAL 12" DIA 115 NOT TO SCALE
G NATURAL GAS LINE PORCH 112'
S/W
115
C/W
114
P UNDERGROUND POWER LINE ASPHALT DRIVEWAY
/L
113 40' MAXIMUM
T
G
OW
P
B W A TE R
G
0
0' C/W
S/W
P
C/W
G
T
P
G G 108
S/W
C/W
110 T T
110 PERFORATED ADS DRAIN
27'-9"
8
PROPOSED ELEVATION CONTOUR LINE 107
10
105
OF DRIVEWAY & COVERED W/ C/W RETAINING WALL, TYP.
106
107
106 12% SLOPE
G 104
G
105
105
BOULDER RETAINING WALL 103
104 TX
4
C/W
S/W COMPACTED CRUSHED
10
ASPHALT 109 102
103
W
3
X C/W
chiefarchitect.com
DIRECTION OF WATER FLOW 102
X
S/W 101
101
S/W X 1 02 100
NATIVE VEGETATION TO REMAIN
100
99
X r=470 ft X 10" CULVERT TRENCH
TRENCH DRAINDRAIN
DETAIL DETAIL
S/W
D/ P NOT TO SCALE
NOT TO SCALE
D
12'-9"
150 ft
12'-11"
D/ P 99.1
4" PERFORATED DRAIN PIPE/ FRENCH D/ P SILT FENCE
D/ P
PLANTING BED S/W
D/ P
D/ P
SEE DETAIL D/ P
DRAIN - SEE DETAIL. 99
D/ P
D/ P D/ P D/ P D/ P D/ P D/ P
D/ P
D/ P
S 2% SLOPE 100.68
4" SOLID DRAIN PIPE EASEMENT 6" MIN. DEPTH
TRENCH DRAIN 2"-4" CRUSHED
DRY LAND GRASS/ NATIVE COARSE ROCK
EDGE OF ASPHALT
VEGETATED AREAS TO REMAIN
LOWER WALL:
208.292.3400
ALL DRIVEWAY STORMWATER
RIP RAP DISSIPATION- 18"LENGTH X BOW 99, TOW 104.5 PROPOSED BOULDER
RUN-OFF SHALL BE DIRECTED
10'
20'
18"WIDTH X 6" DEPTH OF 3-6" SIZE ROCK AT UPPER WALL: RETAINING WALL, TYP.
TO EXISTING STORMWATER
BOW 104.5, TOW 109.5
INFILTRATION BASIN OVERFLOW LOCATIONS CULVERT INLET
SHEET NUMBER
3 Revision #:
1. CODE: 2012 BC
2. CONTRACTOR TO VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS AND NOTIFY
122'
ENGINEER OF ANY DISCREPANCIES PRIOR TO START OF WORK.
3. THE CONTRACTOR, SHALL BE RESPONSIBLE FOR STRUCTURAL STABILITY DURING
CONSTRUCTION, INCLUDING STABILITY OF ALL TEMPORARY CUTS. THE STRUCTURE 116'
SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER THE FINAL DRIVEWAY PAD
DATE: 2.20.2017
ROCKERY WALL
STACKED AS ONE COURSE, PROVIDED THAT THESE ROCKS ARE IN CONTACT AT TWO T2 1/8" = 1'
POINTS OR MORE.
7. WHEN THE WIDTH OF THE BASE ROCK EXCEEDS 5'-6", TWO APPARENTLY EQUAL SIZED
ROCKS MAY BE SUBSTITUTED TO FORM ONE COURSE, WITH ONE AT THE FACE AND ONE
S. TERRAIN SECTION
DETAIL
BEHIND. THIS SUBSTITUTION SHALL BE MADE ONLY AT ONE OF ANY TWO ADJACENT STONE RETAINING WALL
ROCKS. SLOPING BACK TO
137' CORNER LOT
8. PLACE BASE, FACING AND CAP ROCKS SO THAT THEIR HEIGHT DIMENSION IS NOT CENTER OF LOT
ELEVATION
GREATER THAN THEIR WIDTH. THE LONGEST DIMENSION SHALL BE PERPENDICULAR, TO
10' APPROX.
THE FACE OF THE ROCKERY.
9. SURROUND PERFORATED PIPE ON ALL SIDES BY AT LEAST 4" OF GRANULAR DRAIN ROCK
10. DISCHARGE OUTLET PIPES TO A PROTECTED OUTLET OR OTHER PERMANENT DRAINAGE 122'
STRUCTURE AT LOW POINTS IN THE ROCKERY AND AT I 00 FT MAX. SPACING. DRAIN
OUTLETS SHOULD NOT EMPTY INTO STORM DRAINS THAT ARE DESIGNED TO BACK-UP
DURING HEAVY FLOWS 116' 111.5' PAD ELEVATION
11. CONSTRUCT ROCKERIES PARALLEL TO CURB GRADE UNLESS OTHERWISE NOTED.
12. GROUND SNOW LOAD: 71 PSF 111.5'
VEHICLE SURCHARGE: 5OPSF
WIND UPLIFT: 5 PSF
WIND SPEED= 90 MPH EXP C MAX SLOPE 2:1
TERRAIN CUT LINE
SEIS. ZONE= C
SOIL BEARING= 1500 PSF
100.7' ROAD
GRANDVIEW
T2 1/8" = 1'
'C'
1'-6"
GRADE
N49 5
S61 25' 10"W
154.67
CAP ROCK GEO-TEXTILE BETWEEN BEAR ON CHINKING ROCKS
155.83 ft
9' 11"E
1 RETAINED SOIL AND
1
ft
chiefarchitect.com
DRAIN ROCK, TYP. MIN (2) CONTACT
UNIFORMLY LARGEST 4
1.5 MIN. POINTS EA. ROCK TO
1V:1.5H MAX. INCLINATION
TO SMALLEST, BOTTOM GRANULAR ROCK ROCKS BELOW, TYP.
FOR TRANSITION IN
TO TOP, TYP. BACKDRAIN WALL HEIGHT
6'
'H'
VERTICAL SEAMS SHALL
BASE ROCK BACK FACE OF ROCKERY 12" DEEP CLEAN DRAINING EXTEND NO MORE THAN
5% MIN. SLOPE TYP. TO BE APPROX. VERT. CRUSHED COMPACTED (2) ROCKS IN HEIGHT
GRAVEL BED BELOW ROCKS
4" PERF. DRAIN PIPE
2' MIN. WRAPPED IN FILTER VERTICAL STEPS AS NECESSARY
208.292.3400
2 FABRIC w/ CLEAN DRAIN TYPE I-B NON-WOVEN GRADE
1 MAX.
1' MIN.
ROCK
8"
BOTTOM OF FOUNDATION
r=470 ft
ROCK SHALL BE INCLINED
150 ft
1' MIN. NO STEEPER THAN 1V:10H
'B'
3'
SHEET NUMBER
9
4
40' E5
Revision #:
14'-11" 3'-11" 9' 12'-2" 7
1'-10" 2'-4" 1'-11"
5' 4'-1" 6'-11" 4'-4" 4'-6" 4'-1" 5'
W1-12 W1-13 W1-15 W1-16 W1-12
2'-5"
1'-9"
CLOSET
3'-8"
14'-2"
19 SQ FT SHOWER
5'-1 1/2"
17 SQ FT
11'-2"
DATE: 2.20.2017
10'-10 1/2"
D1-07
9'-9"
11'-2"
3'-11"
S7 S5 S6
W1-07
11 9 8
7'-5 1/2" BATH
14'-2"
50 SQ FT 62'
5'-8"
4'-4"
3'
BEDROOM 3 CLOSET
D1-07 D1-07
18' 20' 24'
3'-7"
163 SQ FT 3'-3" 4 1/2" 3'-3"
31 SQ FT 4 1/2"
6"
5'-6 1/2" 2'-11" 2'-5"
3'-3 1/2" BEDROOM 2 SUITE 3'-7" 3'-7" 3'-7" 5' 7'-7" 3'-5" 8'
157 SQ FT
10 1/4"
1'-11" 1'-2"
D1-04 W1-05 W1-05 W1-05
W1-04
4'
D1-07 W1-04 W1-04
4'-5"
PATIO 1'-11" 2'-0 1/2"
6"
6'-10 1/2" 5'-5"
3'
D1-07
1'
W1-06 1'-10" 1'-9" 2'-6 1/2" 2'-6"
S3
3'
J&J BATH 8 8'-8 1/2" 11'-3"
6" 6"
7'-8"
6'-9"
D1-09
82 SQ FT
30'
LAUNDRY D1-07
W1-18
STORAGE
6"
47 SQ FT
4'-7"
2'
D1-07
23 SQ FT
3'
2'-5"
D1-07
W1-16
4'-1" 9 1/2" 3' 5'-6" 3' S5 S5 W1-15 W1-09 W1-08 W1-08
1'-5"
2'-2 1/4"
D1-07 6" 8 8
4'-1"
GAS FP
D1-04
2'-1"
KITCHEN
61120PT
5'-1"
2' 13'-5 1/2"
3'-7"
BEDROOM 4
6'
10'-6 1/2"
163 SQ FT
8'-7"
D1-04
4'-3 3/4"
6'-1"
Half Wall 42"H
CLOSET1'-9"
POWDER w/ Glass on Top
11'-1"
10'-10 1/2"
UP CLOSET
12'
4"
S1 34 SQ FT 93 SQ FT
3'-11"
11'-2"
5
SHOWER MASTER BATH
2'-9"
W1-07
11 1/2"
5'-2"
D1-10 D1-07 44 SQ FT 139 SQ FT
OPEN CEILING
4'-7 1/2"
4'-1 5/16" 7'-3 3/16" 4'-10" 2'-10" 3' LIVING
3'
D1-07
4'-1"
11 1/2" 5'-2" 7'-3 1/2" 10'-8"
6"
3'-8"
MUD AREA
4'-8"
14'-2" 9' CEILING
W1-07
3'-9"
W1-11 D1-13 D1-13
PANTRY
1' 10'-10" 3'-1" 19'-2" 3' 2'-0 1/2" 2'-0 1/2"
3'-1" D1-04 3'-11"
1'-11"
4'-6"
UP
34'
6' 9' CEILING 8'
CRAWL SPACE 1'-6"
4'-1"
6'-8"
E4 ACCESS UNDER FIRE BARRIER W1-10
E6
10'-8 1/2"
9" 6"
31 SQ FT
2'-2" 5 1/2"
HVAC
7 STAIRWAY 3'-8 1/4" 8'-2" 3'-8 1/4" 2'-9" 9' CEILING
5'-2" 3' 4'-7 1/2" 7
D1-14
8080 D1-11 D1-07
27" X 36"
ENTRY
CLOSET
4'-10 1/2"
VAULTED CEILING 5:12
3'-1"
GRANDVIEW
D1-07
W1-19 W1-03
TREY CEILING 8:12
12' CEILING DORMER OPENING
10'-10 1/2"
22'
W1-01
10' CEILING
D1-01
25'-6 1/2"
27'-6 1/2"
14'-10 1/2"
GARAGE
6'-2"
4'-5 1/2" 11'-1" 4'-5 1/2" OFFICE
15'-4"
862 SQ FT
167 SQ FT
28'
6'
PORCH 15'-6 1/2"
VAULTED CEILING 3:12
MASTER BDRM
9'-6"
D1-02
12' @ BOTTOM
3'-1"
251 SQ FT D1-09
10'-1"
S7 2'-11 1/2" 2'-11 1/2"
17'-1"
14'-10"
8
2'
4'
W1-02
PATIO
3'-1"
D1-12 12'-1"
FLOOR PLAN NOTES: 20' 16'
2'-11 1/2"
18'
2'-11 1/2"
2016
1. ALL EXTERIOR DIMENSIONS ARE TO D1-16 54'
3'
WALL LEGEND
FLOOR PLAN - MAIN FLOOR
208.292.3400
ROOM DIVIDER / RAILING WALL
1/4"=1'
4" INTERIOR WALL
SHEET NUMBER
5
1. HEAT LOSS CALCULATIONS SHALL COMPLY WITH REScheck AND/OR
Revision #:
REQUIREMENTS OF LOCAL CODES.
2. PORCHES, DECKS, BALCONIES, FOUNDATION AND GARAGE AREAS NOT
34'
INCLUDED IN LIVING AREA.
3. ALL EXHAUST FANS TO BE VENTED DIRECTLY TO THE EXTERIOR. ALL 10'-8 1/2" 10' 13'-3 1/2"
PENETRATIONS OF THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULK
DATE: 2.20.2017
9'
9'
THE EQUIVALENT RATING OF THE WALL, FLOOR OR CEILING THROUGH
WHICH THEY PENETRATE, UNO.
4. MINIMUM INSULATION:
OPEN TO
ATTICR-50
BELOW
DN
WALLS R-21
STAIR SECTION/DETAIL
FLOORS R-38 8' CEILING
27'
FAMILY 9'-6" CEILING
16'
3'
18'
W2-01
7'-1 3/16"
UNDER STAIR
4"
ACCESS FROM GARAGE
3'
W2-01
2'-6"
D1-03
2'
W2-01 W2-01 W2-01 W2-01
6 13/16"
1'-6" 4" 4"
11" FINISHED 10' 3' 3' 3' 3' 3' 3'
1'-2 1/2" 2'-7 1/2"
8'-5 1/2"
SUB FLOOR FLOOR 12'-8 1/2" 21'-3 1/2"
10'-5 1/2"
BALCONY
STAIR SECTION
GRANDVIEW
1/2" = 1'
1. PROVIDE SPECIAL INSPECTION, SPECIAL TESTING, REPORTING
AND COMPLIANCE PROCEDURES ACCORDING TO THE LOCAL 34'
BUILDING CODE.
STAIR NOTES: LIVING AREA
2. SPECIAL INSPECTOR QUALIFICATIONS: DEMONSTRATE 587 SQ FT
COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, 1. STAIRWAYS SHALL HAVE A MIN. WIDTH OF 34". HAND RAILS MAY ENCROACH A MAX. OF 3 1/2" INTO THE S3 S4
FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION REQUIRED WIDTH. 8 9 FLOOR PLAN - FLOOR 2
OR OPERATION IN QUESTION. PRIOR TO THE BEGINNING OF 2. TREADS SHALL HAVE A MIN. WIDTH OF 10". STAIR TREADS MUST BE UNIFORM AND CAN NOT VARY FROM THE 1/4"=1'
CONSTRUCTION, REVIEW THE SPECIAL INSPECTION LARGEST TO THE SMALLEST BY MORE THAN 3/8".
REQUIREMENTS WITH THE ARCHITECT, ENGINEER, BUILDING 3. STAIRWAYS SHALL HAVE MIN. 6'-8" OF HEADROOM AT THE NOSE OF THE STAIR.
OFFICIAL, GENERAL CONTRACTOR AND SPECIAL INSPECTORS. 4. ENCLOSED USABLE SPACE UNDER INTERIOR STAIRS SHALL BE PROTECTED ON THE ENCLOSED FACE WITH 5/8"
DUTIES OF THE SPECIAL INSPECTOR INCLUDE, BUT ARE NOT TYPE "X" GYPSUM WALL BOARD.
LIMITED TO: 5. STAIRWAYS SHALL HAVE AT LEAST ONE HANDRAIL LOCATED 36" ABOVE THE NOSING OF TREADS AND
A. OBSERVE THE WORK FOR CONFORMANCE WITH THE LANDINGS. THE HAND GRIP PORTION OF HANDRAILS SHALL NOT BE LESS THAN 1-1/2" OR GREATER THAN 2" IN
APPROVED PERMIT DRAWINGS AND SPECIFICATIONS. BRING CROSS-SECTIONAL DIMENSION.
DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE 6. HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS. THE ENDS OF HANDRAILS SHALL 2016
CONTRACTOR FOR BUILDING OFFICIAL. RETURN TO WALL OR TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL.
B. FURNISH INSPECTION REPORTS FOR EACH INSPECTION TO 7. STAIRWAYS HAVING LESS THAN 2 RISERS DO NOT REQUIRE A HAND RAIL.
THE BUILDING OFFICIAL, ARCHITECT, ENGINEER, GENERAL 8. GUARDRAILS SHALL BE PROVIDED FOR AT PORCHES, DECKS, BALCONIES, STAIRWAYS AND LANDINGS WHERE
chiefarchitect.com
THE ADJACENT SURFACE IS GREATER THAN 24" BELOW AND SHALL HAVE A 34" MIN. HEIGHT
C. SUBMIT A FINAL REPORT STATING WHETHER THE WORK 9. RAILING AND GUARDRAIL BALUSTER SPACING SHALL BE NO GREATER THAN 4".
REQUIRING SPECIAL INSPECTION WAS INSPECTED, AND WHETHER 10. THE TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF GUARDRAIL SHALL NOT ALLOW A
THE WORK IS IN CONFORMANCE WITH THE APPROVED PERMIT 6" DIAMETER SPHERE TO PASS THROUGH.
DRAWINGS AND SPECIFICATIONS.
208.292.3400
REQUIRED.
B. MAINTAIN ACCESS TO WORK REQUIRING SPECIAL INSPECTION MIN. HEADROOM 6' 8"
SOFFIT
SHEET NUMBER
40'-7" 62'-7"
6
7" 10 1/2"
Revision #:
40' D1 18' 20' 23'-8 1/2"
11'-11"
112' TOW
DATE: 2.20.2017
30"X30"X8" FTG
4'
S3
FOUNDATION PLAN
W/ (4) #4 E.W. 6" CONCRETE WALL W/ #4 VERT
CL 8 VENT
31'-4"
CL
8'-10"
2'
2X4 @ 16" O/C CL
'SSTB16' 'SSTB16'
FURRING WALL
24"X8" DIA.
FOOTING 'SSTB16'
18'-4"
18" X 8" FOOTING W/ (2) #4 CONT. 115.5' TOW
2' CL FOR FURRING WALL USED TO BEAR
CRAWLSPACE FLOOR JOISTS, UNO
13'-8"
12'
(2) 2X8 HDR
10'-1"
9'-4"
2X4 PONY WALL (1) 2X KING FURRING WALL
115.5' TOW
16" X 8" FTG W/ (2) #4 CONT. TYP. @ CRAWL
8" CONCRETE WALL
TYP. UNDER PONY WALL SPACE ACCESS 112' TOW
'SSTB16'
1'-1"
CRAWLSPACE
34'
112' TOW
11'-8"
C.J.
VENT
GRANDVIEW
110' TOP OF WALL TYP.
19'-8"
22'
GARAGE FLOOR
3'X3'X8" FTG 5'X6'X12" FTG
W/ (4) #4 E.W. W/ (7) #4 E.W. 'SSTB28'
'SSTB28'
27'-5"
5'
20' 2X4 @ 16" O/C
6'
14'-10"
C.J.
2'
FURRING WALL
CL 4'X68"X8" FTG
2'
6'
4'
113.33' TOW
2'
4'
3'X3'X8" FTG
S W/ (4) #4 E.W.
1'-8"
5' 8 3/4"
5'-7" 12'-6 3/4" 3'
6'-8"
112' TOW
3'-1"
3' 'SSTB24'
110.33' TOW 3'
2016
3'
S7 S5 S6
2'
2'X3' FTG W/ #4 @
110.33' TOW 11 9 8
8" O/C EA-WAU
'SSTB28'
chiefarchitect.com
110.33' TOW
10" 1'-10" 10 1/2"
13'-2" 20'-10" 20' 16' 18' 7'-8 1/2"
34' 62'-7"
S3 S4
8 9 FOUNDATION PLAN - FLOOR "0"
FOUNDATION NOTES 1/4"=1'
8" CONC. STEM WALL W/ #4 VERTS @18" O/C W/ STD 90 HOOK INTO FTG. & #4 HORIZ. @ 12" 0/C
1. FOUNDATIONS TO BEAR A MINIMUM OF 24 BELOW FINISH GRADE
208.292.3400
2. ALL ANCHOR BOLTS TO BE 5/8 DIA X 10 @ 32 O/C UNO.
3. ALL REINFORCING STEEL SHALL BE ASTM A-615, GRADE 60.
4. ALL REINFORCING STEEL TO OVERLAP A MINIMUM OF 24 FOR SPLICES.
5. PROVIDE CORNER BARS TO MATCH CONTINUOUS STEEL.
6. MINIMUM ALLOWABLE CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI AT 26 DAYS. MAXIMUM AGGREGATE SIZE IS
1. MAXIMUM AIR ENTRAINMENT IS 3%. CEMENT SHOULD BE TYPE 1 OR 2.
7. SOIL BEARING CAPACITY ASSUMED TO BE 1500 PSF (UBC TYPE 4 SOIL). IF SOIL CONDITIONS VARY FROM THIS, THE PROJECT
ENGINEER MUST BE NOTIFIED. ALL FOOTINGS MUST BEAR ON UNDISTURBED SOIL. ALL SLOPES MUST BE STABILIZED.
8. ADJACENT GROUND SURFACES SHALL BE SLOPED AWAY FROM STRUCTURE DRAINAGE OF SURROUNDING AREA SHALL
ALSO BE PROVIDED TO PREVENT ACCUMULATION OF SOIL AND EROSION OF SOIL NEAR FOOTINGS.
9. UNIFORM SOIL CONDITIONS, MUST BE PROVIDED UNDER SLAB AND FOOTINGS. CUT/FILL OR NON-UNIFORM SOIL
CONDITIONS SHOULD BE EXCAVATED AND REPLACED W/ UNIFORM ENGINEERED FILL MATERIAL TO MINIMIZE DIFFERENTIAL
MOVEMENT.
10. THE TOPS OF FOUNDATION WALLS SHALL EXTEND 6 ABOVE THE ADJACENT FINISH GRADE
11. MINIMUM 18 CLEARANCE FOR WOOD JOIST GIRDERS REQUIRED IN THE CRAWL SPACE UNLESS TREATED WOOD IS USED
OVERVIEW RENDERING
THROUGHOUT FLOOR SYSTEM FOR ILLUSTRATION ONLY NO SCALE
Top Ridge 4
SHEET NUMBER
25.8' FALSE DORMER
7
1'-8"
Revision #:
Top Ridge 3
24.1'
STAGGERED EDGE SHAKE SEAMED METAL ROOFING
1'-8"
PANEL FIBER CEMENT 2:12
BOARD/BATTEN FIBER CEMENT
Top Ridge 2
5'-10 3/8"
22.4' ASPHALT SHINGLE ROOFING
DATE: 2.20.2017
3'-5 5/8"
8 DECORATIVE BEAM
12' 1 1/8
7" LAP CEDAR
TEXTURE
Top of Subfloor - 2nd
8.4' FIBER CEMENT
ELEVATIONS
EXTERIOR
8'-5 1/4"
STONE CAP
Top of Slab
-2.3'
2'
Top of Footing
-4.3' CULTURED, DRESSED FIELDSTONE
FRONT ELEVATION
1/4"=1'
Top Ridge 7
24.5'
4'
Top Ridge 6
GRANDVIEW
6'
Top Ridge 5
14.5'
Ridge
5'-5 3/8"
3'-11 7/8"
12' 1 1/8
5'-10 3/8"
9'-1 1/8"
Top of Wall
3.2'
Top of Subfloor 2016
0.0'
2 1/4"
6'-5"
Top of Foundation
-0.2'
chiefarchitect.com
Top of Footing Top of Footing
-3.2' -3.2'
REAR ELEVATION
1/4"=1'
208.292.3400
S. SIDE ELEVATION N. SIDE ELEVATION
1/8"=1' 1/8"=1'
SHEET NUMBER
8 Revision #:
ATTIC
DATE: 2.20.2017
GLASS
145 1/8"
66 5/8"
121 1/8"
109 1/8"
109 1/8"
109 1/8"
& DETAILS
SECTIONS
1/2"
42"
S5 LIVING SECTION
3/8" = 1'
GRANDVIEW
@ TOP & BOTTOM FLANGES
D3 STRUCTURAL I-BEAM
8 SPAN BETWEEN POSTS
CONCRETE SLAB
SLOPE 1/4" FROM HOUSE WELDED WIRE FABRIC
6X6XW2-9XW2-9 D3
IBEAM SPAN TO POSTS
iJOIST P.T JOIST ICE & WATER SHIELD. 8
2016
INSTALL UNDER SIDING
D4 STRUCTURAL I-BEAM 3/4" T&G PLYWOOD D4 STRUCTURAL I-BEAM
8 TO STEEL POST 8 TO STEEL POST
@BOTH SIDES
3/16
I-BEAM SIDE
EQ EQ
STEEL I-BEAM PER PLAN
STEEL PLATE x6x10
" A307 BOLTS
1"
STEEL POST PER PLAN
208.292.3400
@BOTH SIDES
D8 OF FLANGE
D52 POST TO FLOOR
1/8
5/8" THD'D STUDS
D5 POST TO FLOOR 8 CONNECTION@ 24" O/C FOR WALL PLATE
10 I-JOIST PER PLAN
I-BEAM END
D4 I-JOISTS TO I-BEAM / I-BEAM TO POST CONNECTION
8 CONNECTION HANGER PER PLAN
POST
8 1"=1'
3/16
I-BEAM SIDE
1/4
EQ EQ
5/8"
STEEL PLATE
10"
STEEL I-BEAM PER PLAN
3/4"
ANCHOR BOLTS
STEEL PLATE x6x10
" A307 BOLTS STEEL POST PER PLAN
1"
STEEL POST PER PLAN
10"
9
8
FLASHING
Revision #:
12 STONE CAP
2 FLASHING
GRADE 6" 2X FRAMING
BELOW WALL MEMBER
1/2" SHEATHING
40 1/2"
DATE: 2.20.2017
37"
12 VAPOR BARRIER
5 DRAINAGE SYSTEM REBAR TYP.
D1 RETAINING
RETAINING FOUNDATION
FOUNDATION ANDWALL
AND EXTERIOR EXTERIOR WALL
9 3/8"=1'
109 1/8"
& DETAILS
SECTIONS
VAPOR BARRIER
SHEATHING
KITCHEN OFFICE FINISHED FLOOR
SIDING
SUB-FLOOR
TREATED SILL PLATE
JOIST FLASHING
CAST-IN-PLACE ANCHOR BOLT
JOIST HANGER
LAP JOISTS
VAPOR BARRIER
2 - #4 STEEL REBAR
D2 DRAINAGE SYSTEM
9 2X4 FRAMED BEARING WALL
VAPOR BARRIER TYP. 18" MIN. CLEARANCE
D2 FOUNDATION / /FLOOR
FOUNDATION FLOORDETAIL
DETAIL
9 3/8"=1'
OFFICE SECTION
S1 3/8" = 1'
12
8
GRANDVIEW
2
40 1/2"
TREY CEILING
LSTA24 TYP. @ EA. RAFTER
FORMED BY TRUSSES 1 3/4" LVL RIDGE BOARD
12 SDWC15600 TYP. BEVELED BEARING BLOCK
17"
8 EA. RAFTER END RAFTER PER PLAN
16 1/8"
97 3/4"
8'-1 1/8"
97 1/8"
2016
ATTIC STAIRWAY FAMILY BEAM PER PLAN
BALCONY
D6 GABLE BEAMS TO RAFTERS
7 1/4"
4 7/8"
9
9 1/4"
GLB
109 1/8"
1/4"
PL1/4" KNIFE PLATE w/
(4) SDWS 3" TO BEAM &
(2) 1/2" DOWELS TO POST
5"
COUNTERSINK & PLUG
9'-7 1/8"
115 1/8"
115 1/8"
208.292.3400
KING POST PER PLAN
3"
KNIFE PLATE CONN.
1 1/2"
SHOWER CLOSET LAUNDRY
GARAGE
D1
9
4"
CRAWL SPACE
D7 POST TO GLB KNIFE PLATE CONNECTION
ACCESS
9 1"=1'
S4 GARAGE/FLOOR 2 SECTION
3/8" = 1'
1 2 3 4 5 6
WALL PANEL NOTES:
SHEET NUMBER
10
S4
F4 9 F2
11
Revision #:
11
AA
O TYPE. @ ALL EXTERIOR WALLS, UNO
F3
11
SHEAR WALL PER SCHEDULE
A
DATE: 2.20.2017
B
S3
8 1
'HDU2' F3
'HDU2' 11
SHEAR WALL PLAN, FLOOR 2 S5
8
S5
8
'HDU2'
A
3/16"=1'
SHEAR WALL
LOCATIONS
S1
5
'MSTC52' ACROSS
RIM BOARD
PERF.
C
B 'HDU2' 4 F1
B 'HDU5'
11
'HDU8'
PERF.
PERF.
A
A PERF. 1
PERF.
13 B C
2 4
B
'HDU8' PERF.
D7 D 'HDU8'
8
6 D
B2
6 'HDU5'
'MSTC52' ACROSS
'MSTC40' TO STEEL PERF.
RIM BOARD
BEAM BELOW A S7
GRANDVIEW
BEAM BELOW C
C 'HDU5' S7 S5 S6 F2
D6 F1 11 9 8 11
8 11
WIND
F4 'HDU8'
F4 D8
11
11 9 SEE PORTAL FRAME DETAIL
WIND
2
S3
8
S4
9 3 S3 S4 SHEAR WALL PLAN, MAIN FLOOR
N 8 9
3/16"=1'
chiefarchitect.com
@ 3" O/C AROUND PERIMETER 5 'HDU8' W/ 'SSTB28'(7 8") (2) 2x 20-'SDS' "x2" SCREWS IL E 7
16 " O.S.B. OR 12" PLY. (2) FACES, BLK'D, 8d 6" O.C. 12" O.C. (2) ROWS16d @ 6" O.C. A35 @ 8" O.C. 24" O.C. 2,5,6
NA
6 'HDU8' W/ 'SSTB28'(7 8") (3) 2x 20-'SDS' "x2" SCREWS F 7
16 " O.S.B. OR 12" PLY. (2) FACES, BLK'D, 8d 4" O.C. 12" O.C. (2) ROWS16d @ 4" O.C. A35 @ 6" O.C. 16" O.C. 2,4,5,6
T
7 'HDU11' W/ 'SB1x30'(1") 6x OR (4) 2x 30-'SDS' "x2" SCREWS J OIS G 7
16 " O.S.B. OR 12" PLY. (2) FACES, BLK'D, 8d 3" O.C. 12" O.C. (2) ROWS16d @ 3" O.C. A35 @ 6" O.C. 12" O.C. 2,4,5,6
RIM 7 1
8 'HDU11' W/ 'SB1x30' (1") 8x OR (5) 2x 30-'SDS' "x2" SCREWS D 16 " O.S.B. OR 2" PLY. (2) FACES, BLK'D, 8d 2" O.C. 12" O.C. (2) ROWS16d @ 2" O.C. LPT4 @ 8" O.C. EA. SIDE 9" O.C. 1,2,4,5
10' MAX.
E N G TH H
N
9 'HDU14' W/ 'PAB8' (1") 6x OR (4) 2x 36-'SDS' "x2" SCREWS LE J 7
16 " O.S.B. OR 12" PLY.BLK'D, 10d 3" O.C. 12" O.C. 16d @ 2.5" O.C. A35 @ 8" O.C. 12" O.C. 2,5,6
"
OR ALTERNATE PER 11" EMBED. W/ 17" 1 5/8
R " GYP. UNBLK'D, 5d COOLER OR #6" SCREW 7" O.C. 7" O.C. 16d @ 8" O.C. 16d TOENAIL @ 6" O.C. 48" O.C. 3
NOTE 8 COVER HORIZ. ALL SIDES MIN FO S K
V IDEANCERAP L 5
GYP. BLK'D,5d COOLER OR #6-1" SCREW 7" O.C. 7" O.C. 16d @ 8" O.C. 16d TOENAIL @ 6" O.C. 48" O.C. 3
10 'HD19' W/ 'PAB9' (118 ") 6x OR (4) 2x 5-1" 'A307' BOLTS O T T 8"
PR DIS ST' S OF
OR ALTERNATE PER 12 12" EMBED. W/ 19" D M ER S M 5
GYP. BLK'D, 6d COOLER OR #6-1" SCREW 4" O.C. 4" O.C. 16d @ 8" O.C. 16d TOENAIL @ 6" O.C. 48" O.C. 3
E N & 'C MBENERD. .
8"
COVER HORIZ. ALL SIDES S ' U
NOTE 8 ' C N
L S T EN ED N 1
2 " GYP.(2) SIDES, UNBLK'D, 7" O.C. 7" O.C. 16d @ 8" O.C. 16d TOENAIL @ 6" O.C. 48" O.C. 3
11 'MSTC28' (2) 2x 16-16d SINKERS Q UA FA A CH S CH
E E 5d COOLER OR #6-1" SCREW
(2) 5/8" A.B. PER WALL PER PLAN IN SEE
12 'MSTC40' (2) 2x 32-16d SINKERS STRAP ACROSS FLOOR OR
208.292.3400
5 7" O.C. 7" O.C. 16d @ 6" O.C. A35 @ 32" O.C. 48" O.C. 3
PANEL MIN. 4x OR (2)2x
L E FERS P 8 " GYP. (2) SIDES, BLK'D,
HOLDOWN PER PLAN (MIN.) TO MATCH 13 'MSTC52' (2) 2x 48-16d SINKERS NOT TO SCALE
DU N 6d COOLER OR #6-1" SCREW
C HEASTE
CONC. STEM WALL & WALL WIDTH
14 ES F 4" O.C. 4" O.C. 16d @ 6" O.C.
REINF. PER PLAN EACH SIDE
'MSTC66' (2) 2x 68-16d SINKERS SE Q 5
8"
GYP. (2) SIDES, BLK'D, A35 @ 16" O.C. 32" O.C. 3
CPL'D COUPLE HOLD-DOWNS ACROSS FLOOR, GRADE A36 6d COOLER OR #6-1 " SCREW
CONC. SLAB & REINF. DOUBLE R
THD'D ROD OF SAME IN LIEU OF ANCHOR N PE PERF.SPECIFIED SHEARWALL CONSTRUCTION ALSO APPLIES ABOVE AND BELOW ALL OPENINGS BETWEEN THE FIRST AND LAST HATCHED WALL SEGMENTS
PER PLAN BOTTOM PLATE
NOTES: - D OW
LD LE F.T. SPECIFIED SHEARWALL CONSTRUCTION APPLIES TO HATCHED WALL SEGMENT BESIDE OPENING, FOR THE FULL HEIGHT OF THE OPENING.
1. HOLD-DOWN MARKS ON PLAN APPLY THE BASE OF FRAMED WALLS ON THAT HO E DU
H
PLAN, OR TO TOP OF CONC. U.N.O. SC GENERAL NOTES: FRAMING SPECIFIC NOTES:
2. PANELS FROM INTERSECTING SHEAR WALLS SHALL BE EDGE NAILED TO ALL SOLE PLATES ARE TO BE 2x MIN. 1. FRAMING AT ADJOINING 3. MAXIMUM STUD SPACING 5. MIN. .229x3x3" STEEL PLATE
HOLD-DOWN MEMBERS TO SHARE CORNER HOLD-DOWNS. THE LARGER OF T THICKNESS. PANEL EDGES SHALL BE 3x FOR SHEARWALL IS 16" O.C. WASHERS REQ'D @ EACH
24" MIN.
11
SHEET NUMBER
FRAMING & STRUCTURAL NOTES
Revision #:
1. WINDOW ROUGH OPENING: 1/2" FOR TOP/ (3) 2 X 12
BOTTOM & 1/2" FOR SIDES. CONFIRM WINDOW
MFG. SPECS. BEFORE FRAMING
(3) 2 X 10 (2) 2 X 12
2. WALL HEADERS ON EXTERIOR WALLS: (2) 2" X
10" DF 2 TYP. INSULATED w/ (1) 2x CRIPPLE &
(1) 2X KING, UNO GL 5 1/8 X 12 GL 5 1/8 X 14 1/4
DATE: 2.20.2017
WALL FRAMING
BARRIER IS PROVIDED
7. SEE ROOF FRAMING FOR ADDITIONAL 1/4"=1'
FRAMING DETAIL
LUMBER SPECIES:
A. POSTS, BEAMS, HEADERS, JOISTS, AND
RAFTERS TO BE DF-#2
B. EXPOSED ARCH BEAMS TO BE DF-#1 OR
BETTER, CEDAR
C. SILLS, PLATES BLOCKING, AND BRIDGING TO
BE DF-#2
D. ALL STUDS TO BE DF#2 OR BETTER
E. SHEATHING SHALL BE AS FOLLOWS:
WALL SHEATHING SHALL BE 1/2'' INT-APA
RATED OR 7/16'' OSB
FLOOR SHEATHING SHALL BE 3/4'' T & G INT-APA
RATED PLYWOOD
GRANDVIEW
GL 5 1/8 X 10 1/2 (3) 2 x 10 (3) 2 x 10
2016
F2 SOUTH SIDE WALL FRAME DETAIL
S7 ENTRY/LIVING SECTION
1/4"=1'
chiefarchitect.com
(3) 2 X 10
8'-1 1/8"
1'-10"
9 1/4"
14"
5'-10 3/8"
208.292.3400
9'-1 1/8"
6'-3 1/8"
10'-0 5/8"
23 1/2" 3/4"
4'-2 1/4"
14"
8" 2'-4"
FRAMING OVERVIEW
F4 NORTH SIDE WALL FRAME DETAIL FOR ILLUSTRATION ONLY NO SCALE
1/4"=1'
FRAMING NOTES: S4
SHEET NUMBER
12
9
Revision #:
1. ALL DIMENSIONAL LUMBER SHALL BE DOUGLAS FIR LARCH NO. 2 AND LARGER LUMBER
SHALL BE DOUGLAS FIR NO.1 OR BETTER, UNO.
2. I-JOISTS AND LVL MEMBERS MUST BE INSTALLED IN COMPLIANCE WITH THEIR LISTINGS.
3. ALL TRUSSES SHALL BE ENGINEERED AND STAMPED WITH A SEPARATE ENGINEERED
DOCUMENT. /C
16" O S7 S5 S6
4. PRE-MANUFACTURED WOOD JOISTS & TRUSSES SHALL BE OF THE SIZE AND TYPE SHOWN 10 @
" TJI2
11 9 8
14
DATE: 2.20.2017
FLOOR FRAMING
5. ALL JOISTS AND RAFTERS SHALL HAVE SOLID BLOCKING AT THEIR BEARING POINTS.
CONNECT BLOCKING TO TOP OF WALL W/ SIMPSON FRAMING ANCHORS. ROOF JOIST TO IUS TYP.
HAVE HURRICANE CLIPS @ 48 O.C. OR SIMPSON H-1 HURRICANE CLIPS @ 24 O/C. @ 16" O/C (2) 2X8 HDR
14" TJI210
(1) 2X CRPL 2X4 @ 16" O/C
INSTALL PRIOR TO ROOF SHEETING. 3' FURRING WALL
(1) 2X KING
2'-7"
6. ALL WOOD & IRON CONNECTIONS MUST CARRY THE CAPACITY OF THE MEMBER. THE PROVIDE LSL OR TJI 2X4 @ 16" O/C TYP. TYP. @ CRAWL
CONTRACTOR IS RESPONSIBLE FOR ALL CONNECTIONS. IF OTHER THAN STANDARD BLOCKING, TYP. LAP JOISTS SPACE ACCESS
GRANDVIEW
13. ALL ROOF SHEATHING AND SUB-FLOORING SHALL BE INSTALLED WITH FACE GRAIN
PERPENDICULAR TO SUPPORTS, EXCEPT AS INDICATED ON THE DRAWINGS. ROOF
SHEATHING SHALL EITHER BE BLOCKED, TONGUE-AND-GROOVE, OR HAVE EDGES
SUPPORTED BY PLYCLIPS. SHEAR WALL SHEATHING SHALL BE BLOCKED WITH 2X S7 S5 S6
11 9 8
FRAMING AT ALL PANEL EDGES. SHEATH ROOF PRIOR TO ANY OVER FRAMING.
14. PLYWOOD PANELS SHALL CONFORM TO THE REQUIREMENTS OF "U.S. PRODUCT
ATTIC ACCESS IN
STANDARD PS 1 FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD" OR APA PRP-108
STORAGE CLOSET
PERFORMANCE STANDARDS. UNO, PANELS SHALL BE APA RATED SHEATHING, EXPOSURE
1, OF THE THICKNESS AND SPAN RATING SHOWN ON THE DRAWINGS. PLYWOOD S3
8
S4
9
HSS 5X5X1/4"
6x6 DF #2 POST
4"
3/4" 2 1/2" 3/4" HSS 5X5X1/4" 13.5" X 5 1/8"
3" 1 1/2"
PL 4"x10-1/2"x1/4" w/
(6) SDS x 2-1/2 SCREWS 14" STEEL IBEAM W14 X 30 GLULAM BEAM
S2.5 S2.5
208.292.3400
EACH SIDE OF POST HSS 5X5X1/4"
1/4
S2.5 S2.5
PL 6x6x5/8 S7
8
4"
SHEET NUMBER
13
12 2 X 10 ENERGY
FINISH ROOFING
Revision #:
8 HEEL BLOCKING
ROOFING MEMBRANE
8 : 12
SHEATHING
FLASHING
REDUCED
OVERHANG
DATE: 2.20.2017
FASCIA
8 : 12
8 : 12 HURRICANE CLIP
8 : 12
SUB-FASCIA
8 : 12 8 : 12
SOFFIT
8 : 12
SCREENED VENT
D9 SIDING
13
8 : 12
SHEATHING
8 : 12
8 : 12
8 : 12
8 : 12
D9
8 : 12
8 : 12
PLAN
ICE SHIELD
8 : 12
8 : 12
W/ 'HI' @ EA. END
8 : 12
2x6 LADDER FRAME
8 : 12 @ 24" O/C TYP.
2 : 12
MSTC40 STRAP @ SIDE OR FULL BEARING
2 : 12
8 : 12 8 : 12
POCKET BEAM INTO WALL, GL 5 1/8 X 10 1/2" (3) 2x10 HDR
8 : 12
FULL BEARING W/ (1) 2X CRIPPLE & 8 : 12
GL 5 1/8 X 10 1/2"
GL 5 1/8 X 10 1/2"
GL 5 1/8 X 10 1/2"
GRANDVIEW
'CJT5' 'CJT5'
ROOF PLAN
PREFORMED CURVED BEAM 5 1/2 X 6" GLC (2) 2x6 MIN (2) 2x6 MIN
5.125" X 10.5" MIN. DEPTH D7 3/16"=1'
FOR GL OR 6X12" MIN 9
GLC 5 1/8 X 6"
DEPTH DF#1
KING POST
ROOF FRAMING PLAN
FOR ILLUSTRATION ONLY NO SCALE
TRANSFER LOAD
DOWN TO FTG.
2016
ROOF FRAMING NOTES:
COMBINATION HAND FRAME AND TRUSS FRAMING FOR
ROOF
208.292.3400
TRUSS MANUFACTURER
6. ALL ROOF FRAMING 24" O.C.UNO
STICK FRAME
7. ALL ROOF OVERHANGS 16"; DORMER OVERHANGS
DORMER
10", UNO
8. INSTALL ICE SHIELD AS REQUIRED
9. INSTALL POLYISOCYANURATE FOAM TYPE
(3) 2x6 MIN
INSULATION AT FLOOR AND PLATE LINES, OPENINGS
IN PLATES, CORNER STUD CAVITIES AND AROUND
DOOR AND WINDOW ROUGH OPENING CAVITIES.
10. ATTIC VENTILATION: REQUIRED ABOVE HOUSE
(3) 2x6 MIN
11. ROOF VENTING HIGH/LOW
STICK FRAME
12. ZONE 'B'. MIN. LOAD SHALL BE 50 LBs PER SQUARE
STICK FRAME FALSE DORMER
FOOT BALCONY
13. WALL HEADERS: (2) 2 X 10 DF 2 TYP. UNO
14. ROOF SHEATHING 15/32" OSB OR 1/2" PLYWOOD
32/16 APA RATED W/ 8d @ 6" O/C ALL SUPPORTED TRUSS PLAN
PANEL EDGES, 12" O/C FIELD
15. ROOF TRUSS MANUFACTURER: 3/16"=1'
_____________________________
WINDOW SCHEDULE DOOR SCHEDULE
SHEET NUMBER
14
Window Schedule, Floor 1 Window Schedule, Floor 2
WINDOW NOTES: DOOR NOTES:
Revision #:
3D Exterior Elevation Number Type Qty Width Height R/O Description 3D Exterior Elevation Number Type Qty Width Height R/O Description Door Schedule
3D Exterior Elevation Number Qty Width Height Description Floor
ENTRY 2ND FLOOR
W1-01 Mulled Unit 1 132 " 32 " 133"x33" W2-01 Fixed Glass 6 36 " 60 " 37"x61"
WINDOW FIXED
1 WOOD WINDOWS WITH CLAD EXTERIOR SEE 1. MAIN FLOOR DOORS SHALL BE 96";
D1-01 1 132 " 96 " Entry Door 1
ENERGY RATINGS SECOND FLOOR DOORS 80", UNO
Window Schedule, Attic
3D Exterior Elevation Number Type Qty Width Height R/O Description
2 INTERIOR WINDOW MATERIALS: STAINED 2. ALL DOORS SHALL BE SOLID CORE 1 3/4"
DATE: 2.20.2017
3 WINDOW HARDWARE TO BE OWNER 3. INTERIOR DOORS SHALL BE STAINED -OR- D1-02 1 120 " 96 " ext. Triple Slider-Glass 1
LOWER LIVING
5 SEE WINDOW SCHEDULE CALLOUT FOR CORE DOORS WITH A RATING OF 60
W1-04 Fixed Glass 3 42 " 80 " 43"x81"
WINDOWS
SCHEDULES
W1-05 Fixed Glass 3 42 " 24 " 43"x25"
UPPER LIVING 6 BEDROOM WINDOWS SILL FINISHED MUST BE NET CLEAR DOOR WAY SHALL BE 32" MIN. D1-04 4 34 " 96 " Pocket-Door P03 1
WINDOWS
WITHIN 44: OF THE FLOOR AND PROVIDE DOOR SHALL BE OPENABLE FROM INSIDE
MINIMUM CLEAR OPENINGS OF 5.7 SQ. FEET 6. GARAGE DOORS TO BE SECTIONAL,
W1-06 Fixed Glass 1 24 " 72 " 25"x73" LIVING WITH HEIGHT DIMENSION NOT LESS THAN 24" OVERHEAD DOORS. IF GLASS, IT SHALL BE D1-05 1 30 " 88 " SHOWER DOOR - BEDROOM2 1
MBR -
9. BARN DOORS, MEASURE TO FIT OPENING.
TEMPERED
W1-09 Fixed Glass 1 48 " 54 " 49"x55"
or POLY
GLASS BLOCK
ALL HARDWARE TO BE STAINLESS, UNO
GRANDVIEW
D1-10 1 60 " 80 " 4 Dr. Bifold-Panel 1
1 2 3 4
3) APPLY FLASHING TAPE AT JAMBS, EXTENDING 1" ABOVE AND BELOW WINDOW HEAD FLANGE
AND BOTTOM OF SILL FLASHING. APPLY FLASHING TAPE ALONG HEAD, EXTENDING BEYOND
W1-13 Fixed Glass 1 22 " 22 " 23"x23" CLOSET OUTER EDGES OF JAMB FLASHING.
D1-13 2 36 " 80 " Garage, Fire Rated Door 1
2016
4) REPLACE WRB FLAP AT HEAD AND TAPE REMAINING CUTS IN WRB
208.292.3400
D1-16 1 216 " 96 " Garage-Panel Garage Door 1
W1-18 Fixed Glass 1 54 " 72 " 55"x73" KITCHEN
GARAGE DOOR CASCADE SLIDING DOOR ENTRY DOOR UNIT INTERIOR DOOR BARN DOOR
NOT LISTED IN
W1-19 Mulled Unit 1 94 " 22 " 95"x23" GARAGE U-Factor - Rate of Heat Loss = 1/R SCHEDULE
SHGC - Solar Heat Gain Coefficient
VLT- Visible Light Transmittance QUANTITY (2)
WINDOW ENERGY RATINGS CR - Condensation Resistance RIGHT & LEFT
Low-E4 \High Altitude Windows U-Factor SHGC VLT CR
Casement/Hopper 0.39 0.3 0.49 52
Double Hung 0.35 0.27 0.46 49
Slide-By 0.37 0.28 0.48 49
Fixed \ Auxiliary 0.32 0.32 0.54 51
103 1/2" 116"
71 1/2"
3/4" 3/4" 7 1/2" 3" 3"
SHEET NUMBER
15
24" 30" 30" 18" 40 1/2" 24" 41"
80" 24" 44 1/2"
Revision #:
9"
2 5/8"
33 5/8"
33 5/8"
42"
71 5/8"
DATE: 2.20.2017
107 5/8"
107 5/8"
36"
36"
107 5/8"
1 1/2"
36"
16 1/2"
72"
6"
6"
4"
32"
32"
32"
ELEVATIONS
1" 1" 36" 33" 41"
30" 18" 30" 24" 21" 58 1/2" 30" 41 1/2"
3" 3"
12" 76" 15 1/2" 18" 18" 16 1/2" 63 1/2" 15" 15" 23 1/2" 18"
16" 48" 16" CL CL
CL CL CL CL CL CL
80" 103 1/2" 116" 71 1/2"
177 1/2"
CL CL
28 1/2" 108" 41"
33"
24" 18" 93" 18" 24 1/2"
12
12"
12"
2 5/8"
14 1/8"
101 5/8"
51"
143 5/8"
GRANDVIEW
1 1/2"
72"
107 5/8"
13 1/2"
12
24"
2
42"
21 1/2"
35 1/2"
18"
12
4 7/8" 5"
21" 87" 48" 177 1/2"
5
69 3/8" 96 1/2"
DORMER OPENING CL
165 7/8"
78"
3/4"
3/4"
27 5/8"
12 1/2"
12 1/2"
38 5/8"
38 5/8"
161 3/4"
3/4"
3/4"
2"
3/4"
40"
40"
107 5/8"
107 5/8"
107 5/8"
107 5/8"
107 5/8"
107 5/8"
107 5/8"
52"
208.292.3400
68 1/4"
69"
40"
40"
30"
16
WP
Revision #:
R
GFCI
THERMO FOR
R
HEATED FLOOR.
DATE: 2.20.2017
CD CW
GFCI
Dryer Washer
3
GFCI
GFCI
R
4'-6"
GFCI C5/TV
4 PLEX AT UPPER WALL CAB
WP
4
(2) OUTLETS COFFEE STATION G LIGHTS
30 AFF / 72 AFF
GFCI GFCI
DATA PANEL - NETWORK,
42" IRON STATION SECURITY, AUDIO, CABLE R R WALL CAB UNDERMOUNT
Tub-Shower C CL SP 4 3
HOME 2'-5 1/2" L GFCI GFCI
STRIP LIGHTS
5' 5'-6" 4'-6"
3'
GFCI
GFCI CL CL M
3 GFCI R4
4'
72 AFF
C5/TV Freestanding Bath
4
WALL MOUNTED UNDER COUNTER
GFCI
R R R
R R CL SPEAKER STRIP LIGHTS
GFCI
GFCI
4'
G
1'-10 5/8"
R
AUDIO PLAN
R4 SP RA
Hood
4'
TO LIGHTS ABOVE CL R R
Range
R R CL GFCI
STAIRWAY R T
SP DW SP
R R CL H
2'-2 1/2"
GFCI
4'
(2) OUTLETS CL
1'-10 1/2"
A 42" IRON STATION
CL R R 30 AFF / 72 AFF GD
Sink
GFCI
4'
GFCI R R
CL R R CL R THERMO FOR
4'-6"
A HEATED FLOOR.
R R R
REQUIRES
CL CL R R CL DEDICATED CIRCUIT
4'
2'-2" 5'-2" 2' C5/TV 3 4 4 3 T
CL R R R
5'
HS SP R
3 GFCI
4'
GFCI
Ref
EP EP
GFCI ELEC. PANELS GFCI
33 3 3
GFCI R GFCI CL R R
400 AMP SERVICE SP
Ref. Optional: Water Softener
Sink
GFCI CL R
3'
4'-10"
CL CL CL GFCI
WH
3'-8 3/8"
6'
R4
R CL R R R R R
CL
3'-4"
R R R R R
CL CL
6'-1 1/2" 4'-6" 4'-6" 4'-6" 4'-6" 3'-5 1/2"
G
4'-6"
WH
72 AFF
CL
CL
1'-6 5/8"
R CL R 4 4
C5/TV
3'-5"
R4
C5/TVR SP
CL R R
Gas Heater
5'
3'-10 1/2"
USB
CL
GFCI OUTLET & CABLE 4
3
R CL R R R R R 4
Heat Pump 1
72 AFF
9'
C5/TV
4' 5' 5' 5' 5' 5' 4' R R
2'-6"
CL CL CL CL CL CL
CL
OUTLET & CABLE
3'-10 3/8"
DOORBELL
SP SP
GRANDVIEW
GFCI
C5/TV
GFCI
9'
Heat Pump 2
WP
R R G WP
CL WP R CL R R
C5E
1'-6"
1'-2" 1'-2"
6'-6 3/4" 6'-6 3/4"
CL CL CL
4
ELECTRICAL 4
METER USB CL
2'-4 1/2"
10'-5 1/2"
R R WP
SP
3
3
ELECTRICAL LEGEND
2016
LIGHTING
NOTES:
chiefarchitect.com
Recessed Down Light 6 HOME OWNER SHALL DO A WALK-THRU WITH RELEVANT INSTALLERS TO VERIFY THE EXACT LOCATION FOR OUTLETS, LIGHTS, SWITCHES, CABLE, DATA, PHONE, AUDIO,
UNDER CABINET LED PUCK / LED STRIP /
CEILING LED VACUUM, ETC.
208.292.3400
Contemporary Pendant DETECTORS TO HOUSE POWER AND INTER-CONNECT SMOKE DETECTORS TO HOUSE POWER AND INTERCONNECT SO THAT, WHEN ANY ONE IS TRIPPED, THEY ALL WILL
USB GFCI WP
OUTLETS - USB 5V & 120V / 120V WALL & SOUND. PROVIDE BATTERY BACKUP FOR ALL UNITS.
CEILING
GFCI / WATER PROOF / 220V 6. CIRCUITS SHALL BE VERIFIED WITH HOME OWNER PRIOR TO WIRE INSTALLATION.
R
APPLIANCE SPECIFIC: REFRIGERATOR / 7. FINAL SWITCHES FOR TIMERS AND DIMMERS SHALL BE VERIFIED WITH HOME OWNER.
M DW GD
MICROWAVE / DISH WASTER / DISPOSAL 8. FIXTURES TO BE SELECTED BY HOME OWNER.
H CW CD RA Cylch Semi-Flush Mount
COOK HOOD / WASHER / DRYER / WALL 9. UNO - ALL SWITCHES TO BE 48" O/C ASF. OUTLETS TO BE 15" O/C ASF. OUTLETS OVER COUNTERTOPS TO BE 3" ABOVE COUNTER FROM BOTTOM. (ASF = ABOVE
OVEN SUBFLOOR)
10. ALL LIGHTING SHALL BE DIMABLE AND USE LED BULBS, UNO.
OTHER MEP
AUDIO:
C5 C5/TV
VAC
Duplex
HS
CAT5 / CAT5 & COAX RG6QS / CENTRAL VAC / 1. LOCATE SPEAKERS AND AUDIO CONTROLS AS INDICATED IN THE PLAN; RUN CIRCUIT OF SPEAKER WIRING TO AUDIO HOME PANEL SPECIFIED BY FLOOR;
HOME SECURITY PANEL 2. AUDIO SPEAKERS TO BE APPROVED BY HOME OWNER;
T G SMOKE DETECTOR / THERMOSTAT / GAS 3. LOCATE JACKS AS INDICATED IN THE PLAN; INSTALL DATA / CABLE PANEL SIMILAR TO "ON Q". SYSTEM TO BE APPROVED BY HOME OWNER.
CONNECTION / DOOR BELL
DATA / CABLE:
SP
SPEAKERS: CEILING MOUNTED. NOTE, USE Exhaust LOCATE SECURITY PANELS AS INDICATED IN THE PLAN; SYSTEM TO BE APPROVED BY HOME OWNER.
WALL CONTROLLED VOLUME SWITCH
SHEET NUMBER
17 Revision #:
W C
W
H C
H C
W
H/W H/W
H/W
C/W C/W
w/W
DATE: 2.20.2017
Dryer Washer
H C
W C
C/W
w/W
C/W
H/W
H/W
w/W
HOSE
W
BIBB
G C
Tub-Shower
C/W
H/W
w/W
H C
w/W
H C
C
G
H/W
W
C/W C/W
w/W w/W w/W C W
w/W w/W w/W
w/W w/W
W w/W W
C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W Freestanding Bath
H/W H/WH C H/W H/W H/W H/W H/W H/W H/W H/W H/W H/W H/W
H C
C W
H C
w/W
C/W
C/W
C/W
W
w/W
C/W
w/W
H/W
H/W
C // W
G
G G G G G G G G G
G
G
W
H
C/W C/W C/W
H/W H/W H/W
Hood
H C
DW
Range
PLAN
C
W
C/W
C/W
C/W
C/W
w/W
H/W
H/W
C // W
H/W
G
H
w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W
Sink
H
W
H C
w/W
C/W
C/W
C/W
w/W
H/W
H/W
ALL VENTS NEAR
G
CABINETS INSTALLED IN
W
TOE KICK
H/W
H C C/W
W
Ref
C
C
H
Ref. Optional: Water Softener
Sink
C
C/W
w/W
C/W
H/W
Water Heater2 Water Heater1
G
WH
G
G
WH
w/W
C/W
G
C/W
Gas Heater
w/W
C/W
C/W
G
GRANDVIEW
C
HOSE
BIBB
w/W
C/W
G
Heat Pump 2
w/W
C/W
G
G
w/W
C/W
G
HVAC & PLUMBING PLAN - 2ND FLOOR
w/W
C/W
G
3/16"=1'
G G G G G
208.292.3400
TWO 90 DEGREE ANGLES.
6. PROVIDE 30 CLEARANCE FROM RANGE TOP TO COMBUSTIBLE MATERIALS. FOR EXCEPTIONS, SEE INT. MECHANICAL CODE. SIDE CLEARANCE SHALL BE AS SPECIFIED BY PERMANENT MARKING ON THE UNIT. IRC
M1901.1
7. WATER CLOSETS TO HAVE A FLOW RATE OF 1.6 GALLONS OR LESS PER FLUSH. IRC P2903.2
8. SHOWER HEADS TO HAVE FLOW RATE OF 2.5 GALLONS PER MINUTE OR LESS. IRC P2903.2
9. TUBS/SHOWERS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING TYPE. THE WATER TEMPERATURE SHALL BE AT A MAXIMUM OF 120*F.
10. INSTALL WATERPROOF GYPSUM BOARD AT ALL WATER SPLASH AREAS TO MINIMUM 84" ABOVE SHOWER DRAINS.
11. OPTIONAL WATER SOFTENER UNIT, IF INSTALLED, SHALL CONDITION WATER BEFORE ENTERING THE WATER HEATERS AND THE COLD WATER SOURCE. WATER TO REFRIGERATOR, KITCHEN AND BATH SINKS SHALL
NOT HAVE SOFTWATER.
12. EACH HOSE BIBB SHALL BE EQUIPPED WITH A BACK FLOW PREVENTION DEVICE.
13. ALL GAS LINES SHALL BE SIZED FOR APPLIANCE LOAD. "BLACK" PIPE SHALL BE USED INSIDE THE BUILDING, "GREEN" PIPE WHERE UNDERGROUND OR EXPOSED TO WEATHER. ALL JOINTS SHALL BE TAPED WHERE
BURIED OR EXPOSED TO WEATHER.
14. INSULATE WASTE LINES FOR SOUND CONTROL.
15. INSTALL CENTRAL VACUUM SYSTEM & PIPING; CONFIRM BRAND WITH HOMEOWNER.
214"
SHEET NUMBER
18
1 7/8" 6 1/2" 5 7/8"
136 1/2" 36" 27 1/4"
Revision #:
9"
62 5/8"
DATE: 2.20.2017
107 5/8"
98 5/8"
11"
MASTER BATH
33" 41" 14" 41" 36" 21" 18"
7 1/2" 1" 1 1/2"
136 1/2" 19" 58 1/2"
CL
136 1/2" 77 1/2"
111 1/2"
2"
52 1/2" 21" 36"
62 5/8"
193" 84" FOR ILLUSTRATION ONLY NO SCALE
61" 86 1/2" 36 1/2" 84"
LC
107 5/8"
GRANDVIEW
51
BRITTANICCA
24
11"
5 2 1. VANITY SINK. MIRROR W/
W3051
24"
Bench
1 1/2"
33"
28 1/2"
CL
18"
CL
18 1/2" 2. ELONGATED COMFORT HEIGHT
TOILET; VENT ALONG SHOWER
3
36"
4 WALL
4"
102"
SHOWER 5. SHELF
BATH SINK ELEVATION
1 1/2"
MASTER BATH M3
8 1/2"
ANGLE
139 SQ FT
SLOPE FLOOR TO DRAIN
ASHWOOD 1/2"=1' 2016
3 C 1
W3051
5 6
7. IRON STATION
52 1/2"
102"
CL CL 193"
2
41"
19 1/2"
CL
24"
24"
3"
W482124
64"
M3
SB 36 BF
47 5/8"
47 5/8"
3DB212134
44 1/2"
CL CL
19"
PANTRY
66"
CL
34 5/8"
34 5/8"
BF
107 5/8"
107 5/8"
25 1/2"
12"
12"
77 1/2"
208.292.3400
M1
3DB212134
CL CL
M01 1 18 " 21 " 34 " base cabinet
58 1/2"
9"
9"
1/2"
CL CL
48"
30 1/2"
1DB182134
48"
38 7/8"
9' CEILING
42"
40"
40"
M02 2 21 " 21 " 34 " base cabinet
BF
1/2"
17"
41" 52 1/2"
3"
96 1/2" M03 2 36 " 21 " 34 " Sink Base 8" 37 1/2" 15" 37 1/4" 43 1/4" 18" 18 1/2"
42" 36" 24" C 6" CL CL CL
CL CL 1/2" L
102" 61" 86 1/2" 36 1/2"
193"
TREY
MASTER BATH CEILING
/ CLOSET 8:12 PLAN
FLOOR SHOWER ELEVATION TUB ELEVATION
1/2"=1'
M4 1/2"=1'
M2 1/2"=1'
10' CEILING
190" 96"
1 1/2"
SHEET NUMBER
19
1 1/2" 1"
24" 30" 54" 30" 48" 30" 30" 36"
240"
CL
Revision #:
189" 51"
2 5/8"
2 5/8"
2 5/8"
15" 43" 16 7/8" 59 1/4" 105 7/8"
21"
LC
51"
51"
W
W306915 W3051
36
25"
DATE: 2.20.2017
B3
R
MW
1 1/2"
R
107 5/8"
107 5/8"
107 5/8"
1 1/2"
5 1. VANITY SINK. MIRROR W/
W3051
81 1/16"
K2
16 1/2"
16 1/2"
Bench
KITCHEN
18"
Freestanding Bath INTEGRATED LED LIGHT.
36"
B21L
1 1/2"
2. ELONGATED COMFORT HEIGHT
1 1/2"
62" TOILET; VENT ALONG SHOWER
K5
30 1/2"
K1
34 1/2"
4 WALL
36"
3DB21
Half Wall 42"H 3. FREESTANDING TUB W/ FILLER
4"
RADIUS 146.5"
Range
M4
ELEVATIONS
18.25"; FABRICATOR TO VERIFY30"
DW
190"
1 1/2" 1" 30" 36"
36" 21" 48" 33" 48"
1 1/2"
66
ft
SHOWER 81 1/16" 82 7/16" 26 1/2"
5. SHELF 45" 51"
5.
50 SQ FT MASTER BATH CL
190"
CL
6. OPEN SHOWER, CURBLESS; 96"
CL
WORK TRIANGLE
3DB33
3 C 1
W3051
6.53 ft
82 7/16"
B3912
5 6 MAIN WALL ELEVATION
K2 WALL ELEVATION
125"
Sink
K4 K1 7. IRON STATION
SB 36
1/2"=1' 2 1/2"=1'
5.2 CL CL CL CL
4f
t 62 3/4" 33 1/2" 33 1/2" 33 1/2" 74 7/8" Cabinet Schedule, Kitchen
Elevation # Label Qty Width Depth Height Description
PO21
W482124
59 1/2"
B4212
37 5/8"
CL
3DB212134
FHB21L
PANTRY
26 1/2"
Ref
61"
K02 3DB33 1 33 " 24 " 36 " base cabinet
107 5/8"
9' CEILING 41" 38 1/2"
34"
K03 B21L 1 21 " 24 " 36 " base cabinet
52 1/2"
52"
GRANDVIEW
1 1/2"
9' CEILING K04 B30 1 30 " 24 " 36 " base cabinet
34 1/2"
36"
KITCHEN FLOOR PLAN
K05 B3912 1 39 " 12 " 36 " base cabinet
1/2"=1' VAULTED CEILING 5:12
21" 21" 36" 24" 21" 37" 25"
36"
chiefarchitect.com
24" 12"
LING 3:12
K10 MW-1DB30 1 30 " 24 " 36 " Micro
K4 ISLAND ELEVATION K5
TTOM 1/2"=1'
KITCHEN & CABINET NOTES: K11 PO21 1 21 " 24 " 36 " base cabinet
208.292.3400
2 CONFIRM FINISH & STAIN/PAINT WITH CLIENT PRIOR TO ORDERING
3 CONFIRM DOOR & DRAWER STYLES WITH CLIENT PRIOR TO ORDERING 34 1/2
K12 SB 36 1 36 " 24 " Apron Sink Base
4 INSTALL HARDWARE ON SITE "
5 INSTALL CROWN MOLDING ON SITE; CONFIRM PROFILE AND DIMENSION WITH HOME OWNER
6 CABINET SUPPLIER RESPONSIBLE FOR FINAL MEASUREMENTS & CABINET OPENINGS FOR APPLIANCES
SPECIFICATIONS K13 W3051 3 30 " 12 " 51 " wall cabinet
7 ALL APPLIANCES TO BE ON DEDICATED CIRCUITS, UNO. REFER TO APPLIANCE SPECIFICATIONS FOR AMP/
VOLTAGE REQUIREMENTS
8 USE MIN 6" DUCT FOR HOOD. CONFIRM HOOD IS 500 CFM MIN.
9 CONFIRM FINAL MATERIALS FOR BACKSPLASH AND COUNTERTOP WITH CLIENT PRIOR TO ORDERING K14 W306915 1 30 " 15 " 69 " wall cabinet
10 ALL DRAWERS TO BE TONGUE & GROOVE; GLIDES TO BE SOFT CLOSE
11 LED STRIP LIGHTS FOR WALL CABINETS AND UNDER ISLAND
12 COUNTER FABRICATION: CONFIRM ALL FIXTURE MEASUREMENTS AND CENTERLINES
KITCHEN RENDERING K15 W482124 1 48 " 24 " 21 " wall cabinet