Basic Steps For Foundation Design
Basic Steps For Foundation Design
01. Calculate the size of the footing considering allowable bearing pressure and service load.
02. Calculate the bearing pressure for ultimate loads
03. Check the vertical line shear (shear at face of the column)
04. Check for punching shear
05. Calculate reinforcement for bending
06. Check shear at critical section
Design Example
fck 30N/mm2
fyk 500N/mm2
Assume, footing thickness 500mm, 16mm diameter bars at base and cover to the reinforcement as
40mm
d = 500-40-16/2
= 452mm
Max. Shear resistance
VRD,max = 0.5ud[0.6(1-fck/250)](fck/1.5)
= 0.5*(4*400)*452*0.6*(1-30/250)*(30/1.5)*10^-3
= 3818.5kN
Hence, VRd,max > VEd = 1815kN
Punching Shear
Bending Reinforcements
Consider critical section (at column face)
MEd = 216*2.9*(2.9/2-0.4/2)*(2.9/2-0.4/2)/2
= 490kNm
K = M/[b*(d^2)*fck]
K = 490*E6/[1000*(452^2)*30]
K = 0.08
z = d[0.5+(0.25-K/1.134)^0.5]
z = 452[0.5+(0.25-0.08/1.134)^0.5]
z = 417.5mm (Z/d = 0.92<0.95)
As = M/(0.87*fyk*z)
As = 490*E6/(0.87*500*417.5
= 2698mm2
Provide T25@175mm spacing (As Provided = 2804mm2)
OR you may increase the depth of the footing in order to reduce the reinforcement area.
VRd,c = 0.4*7280*542
= 1316.2kN > 915.84kN