CDB 4313 Heat Integration - Basic Heat Integration
CDB 4313 Heat Integration - Basic Heat Integration
OFFICE: 05-03-08
TELP: 05 368 7562
EMAIL: [email protected]
Discussion time: Friday 15.00 17.00
COURSE OVERVIEW
Data extraction
Composite Curve
Problem Table Algorithm
Grand Composite Curve
Basics Placement of utilities
Process Modification (+/-)
Heat Exchanger Network Design
4. Analyze the potential for heat and power integration of a process and the
possible implementation options, and to screen the options using cost
effective strategy
5. Perform correct data extraction from process flowsheet for the purpose of
performing pinch analysis
3
INTRODUCTION
4
STEPS IN PINCH ANALYSIS
Identify
hot and cold streams
Tmin
Construct
Composite Curves &
Grand Composite Curve
Identify appropriate
process modification
5
HEAT EXCHANGING
10 kg/hr 10 kg/hr
100 oC 80 oC
4 kJ/kgK Q 4 kJ/kgK
kg/hr 5 kg/hr
oC 30 oC
kJ/kgK 3 kJ/kgK
Temperature
(oC)
Q
Q = mcpT
Enthalpy
(kW)
6
DATA EXTRACTION (1)
COND Stream 2
COND H = 330 kW
20O C 170O C
20O C CP = 3 kW/oC
170O C
R2
60O C R2
H = 230 kW 60O C
C1
H = 100 kW C1 Stream 1
H = 230 kW
R1 CP = 2 kW/oC
R1
REB 135O C REB
135O C
150O C
140O C 150O C
H = 150 kW
140O C
102.5O C Stream 4
30O C H = 180 kW Stream 3
90O C CP = 1.5 kW/oC H = 240 kW
H = 90 kW 30O C CP = 4 kW/oC
H = 90 kW
80O C 80O C
7
DATA EXTRACTION (2)
Extracted Data
Stream 2 Stream Type Temp. Temp. Load Flow
COND H = 330 kW supply (oC) req. (oC) (kW) (kW/oC)
20O C CP = 3 kW/oC
170O C 1 Cold 20 135 230 2
140O C
Stream 4
H = 180 kW Stream 3
CP = 1.5 kW/oC H = 240 kW
30O C CP = 4 kW/oC
80O C
8
DATA EXTRACTION (3)
Data extraction rules:
- Linearize data on the safe side
9
DATA EXTRACTION (4)
- Do not extract utilities (it is to be designed!)
- Extract at effective temperature
- For soft data, check if hot/cold utilities can be reduced via composite curve
Why? Why not?
10
COMPOSITE CURVE: COLD COMPOSITE CURVE
140 140
135 135
3 3
80 80
1 1
20 20
110+220
11
COMPOSITE CURVE: HOT COMPOSITE CURVE
170 170
150 150
2
60 60
4
30 30
135+270
Enthalpy (kW) Enthalpy (kW)
(a) (b)
12
COMPOSITE CURVE
13
COMPOSITE CURVE WITH DIFFERENT TMIN
Tmin = 10 oC Tmin = 20 oC
Tmin = 30 oC Tmin = 40 oC
14
PROBLEM TABLE ALGORITHM (ADJ. TEMP.)
Adjusted temperature with T = 20 oC,
Original data
THOT = THOT-0.5 T, TCOLD = TCOLD+0.5 T
Stream Temp. Temp. Flow Stream Temp. Temp. Flow
supply (oC) req. (oC) (kW/oC) supply (oC) req. (oC) (kW/oC)
1 20 135 2 1 30 145 2
2 170 60 3 2 160 50 3
3 80 140 4 3 90 150 4
15
PROBLEM TABLE ALGORITHM (ADJ. TEMP.)
Shift
Interval T(i+1)-Ti mCpnet dH
Temperature
C C kW/K kW
160
1 10 3.0 30.0 surplus
150
2 5 -1.0 -5.0 demand
145
3 5 -3.0 -15.0 demand
140
4 50 -1.5 -75.0 demand
90 PIN
5 40 2.5 100.0 surplus
50
6 20 -0.5 -10.0 demand
30
7 10 1.5 15.0 surplus
20
16
PROBLEM TABLE ALGORITHM (ADJ. TEMP.)
Shift
Interval T(i+1)-Ti mCpnet dH
Temperature Infeasible Cascade Feasible Cascade
C C kW/K kW
160 0 65
1 10 3.0 30.0 surplus 30 30
150 30 95
2 5 -1.0 -5.0 demand -5 -5
145 25 90
3 5 -3.0 -15.0 demand -15 -15
140 10 75
4 50 -1.5 -75.0 demand -75 -75
90 PINCH -65 0
5 40 2.5 100.0 surplus 100 100
50 35 100
6 20 -0.5 -10.0 demand -10 -10
30 25 90
7 10 1.5 15.0 surplus 15 15
20 40 105
17
COMPOSITE CURVE (WITH ADJUSTED TEMPERATURE)
18
GRAND COMPOSITE CURVE (GCC)
Shift Shift
Interval T(i+1)-Ti mCpnet dH Interval T(i+1)-Ti
Temperature Infeasible Cascade
Temperature Feasible Cascade
C C kW/K kW C C
160 0 160 65
1 10 3.0 30.0 surplus 30 1 30 10
150 30 150 95
2 5 -1.0 -5.0 demand -5 2 -5 5
145 25 145 90
3 5 -3.0 -15.0 demand -15 3 -15 5
140 10 140 75
4 50 -1.5 -75.0 demand -75 4 -75 50
90 PINCH -65 90 0
5 40 2.5 100.0 surplus 100 5 100 40
50 35 50 100
6 20 -0.5 -10.0 demand -10 6 -10 20
30 25 30 90
7 10 1.5 15.0 surplus 15 7 15 10
20 40 20 105
19
UTILITY PLACEMENT (VARIOUS OPTIONS)
CH 5 80 oC, 105 kW
20
UTILITY PLACEMENT (VARIOUS OPTIONS)
CH 5 15 oC, 105 kW
21
UTILITY PLACEMENT (VARIOUS OPTIONS)
2
2: Steam at 150 oC, 65 kW
CW 30 80 oC, 90 kW
CH 5 15 oC, 15 kW
22
UTILITY PLACEMENT (VARIOUS OPTIONS)
3
3: Steam at 150 oC, 25 kW,
steam at 120 oC, 40 kW
CW 30 40 oC, 50 kW
CH 5 15 oC, 15 kW
23
COURSE OVERVIEW
Data extraction
Composite Curve
Problem Table Algorithm
Grand Composite Curve
Basics Placement of utilities
Process Modification (+/-)
Heat Exchanger Network Design
25