0% found this document useful (0 votes)
76 views

H H H H: Calculation Sheet Vertical Irregularity of Structures

This document contains a calculation sheet analyzing the vertical irregularity of a 4-story library structure in Timor Leste. It evaluates the structure for two types of irregularities - Type 1a stiffness-soft story and Type 1b extreme soft story - over 4 stories. The results find that all story drift ratios meet the specified limits, indicating the structure does not have any soft story or other vertical irregularities.

Uploaded by

Prima Adhiyasa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
76 views

H H H H: Calculation Sheet Vertical Irregularity of Structures

This document contains a calculation sheet analyzing the vertical irregularity of a 4-story library structure in Timor Leste. It evaluates the structure for two types of irregularities - Type 1a stiffness-soft story and Type 1b extreme soft story - over 4 stories. The results find that all story drift ratios meet the specified limits, indicating the structure does not have any soft story or other vertical irregularities.

Uploaded by

Prima Adhiyasa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 14

Calculation Sheet

Vertical Irregularity of Structures


No. : 10-2533 Date : 02/11/2017

Project : ENI Design : Paa

Location : Timor Leste Checked : ASR

Building : Library Revision : A

Vertical Irregularities
Type 1a (Stiffness-Soft Story Irregularity)
Story = 2 Story Grid : 1.D

SDC = D

X Sides

Story
Height Displacement Story-Drift Story-drift 0.8x(Story- 0.7x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 3.9008 3.9008 0.00076 0.00061 0.00053 - No

2 5150 8.5619 4.6611 0.00091 0.00072 0.00063 - No

Check :

1 0.70 1e
2e
1e

h1 h 2

0.00053 < 0.00091 Ok!

0.80 1e 2 e 1e 3e 2 e 4 e 3e
1 No Irregularity
2

h1 3 h2 h3 h4
0.00061 < - Ok!

Story = 3 Story Grid : 1.C

SDC = D

X Sides

Story
Height Displacement Story-Drift
Story-drift 0.8x(Story- 0.7x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 4.1926 4.1926 0.00081 0.00065 0.00057 0.00083 No

2 5150 8.8876 4.695 0.00091 0.00073 0.00064 - No


3 5150 12.7853 3.8977 0.00076 0.00061 0.00053 - No

Check :

1e
0.70 1e

1 2e

h1 h 2
0.00057 < 0.00091 Ok!

0.80 1e 2 e 1e 3e 2 e 4 e 3e
1 No Irregularity
2

h1 3 h2 h3 h4
0.00065 < 0.00083 Ok!

Story = 4 Story Grid : 1.B

SDC = D

X Sides

Story
Height Displacement Story-Drift Story-drift 0.8x(Story- 0.7x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 4.13 4.13 0.00080 0.00064 0.00056 0.00086 No

2 5150 8.9048 4.7748 0.00093 0.00074 0.00065 0.00077 No

3 5150 12.9502 4.0454 0.00079 0.00063 0.00055 - No

4 3600 15.6895 2.7393 0.00076 0.00061 0.00053 - No

Check :

1 0.70 1e
2e
1e

h1 h 2
0.00056 < 0.00093 Ok!

0.80 1e 2 e 1e 3e 2 e 4 e 3e
1 No Irregularity
2

h1 3 h2 h3 h4
0.00064 < 0.00086 Ok!

Vertical Irregularities
Type 1b (Stiffness-Extreme Soft Story Irregularity)
Story = 2 Story Grid : 1.D

SDC = D

X Sides
Story
Height Displacement Story-Drift Story-drift 0.7x(Story- 0.6x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 3.9008 3.9008 0.00076 0.00053 0.00045 - No


2 5150 8.5619 4.6611 0.00091 0.00063 0.00054 - No
0 0 0 - - - - - -

0 0 0 - - - - - -

Check :

1 0.70 1e
2e
1e

h1 h 2
0.00045 < 0.00091 Ok!

No Irregularity
0.80 1e 2 e 1e 3e 2 e 4 e 3e
1
2

h1 3 h2 h3 h4
0.00053 < - Ok!

Story = 3 Story Grid : 1.C

SDC = D

X Sides

Story
Height Displacement Story-Drift
Story-drift 0.7x(Story- 0.6x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 4.1926 4.1926 0.00081 0.00057 0.00049 0.00083 No

2 5150 8.8876 4.695 0.00091 0.00064 0.00055 - No

3 5150 12.7853 3.8977 0.00076 0.00053 0.00045 - No

Check :

1e
0.70 1e

1 2e

h1 h 2
0.00049 < 0.00091 Ok!

No Irregularity
0.80 1e 2 e 1e 3e 2 e 4 e 3e
1
2

h1 3 h2 h3 h4
0.00057 < 0.00083 Ok!
Story = 4 Story Grid : 1.B

SDC = D

X Sides

Story
Height Displacement Story-Drift Story-drift 0.7x(Story- 0.6x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 4.13 4.13 0.00080 0.00056 0.00048 0.00086 No

2 5150 8.9048 4.7748 0.00093 0.00065 0.00056 0.00077 No

3 5150 12.9502 4.0454 0.00079 0.00055 0.00047 - No

4 3600 15.6895 2.7393 0.00076 0.00053 0.00046 - No

Check :

1e
0.70 1e

1 2e

h1 h 2
0.00048 < 0.00093 Ok!

No Irregularity
0.80 1e 2 e 1e 3e 2 e 4 e 3e
1
2

h1 3 h2 h3 h4
0.00056 < 0.00086 Ok!

Vertical Irregularities
Type 2 (Weight (mass) Irregularity)
Story = 4 Story

SDC = D

Weight 1.5 x Weight Check Mass Check :


Story Status
ton ton Weight Mass Irr. No Irregularity

0 0 0 -

1 466.87 700.305 No 0

2 896.26 1344.39 No 0

3 734.094 1101.141 No 0

4 120.981 181.4715 No 0

OK

Vertical Irregularities
Type 3 (Vertical Geometric Irregularity)
Story = 4 Story

SDC = D

Width Check :
Ratio
Story Width ratio Status
m Ratio > 1.3

2 15 1 No 1 > 1.3 No Irregularity

3 15 0 No

Vertical Irregularities
Type 4 (In-Plane Discontinuity in Vertical lateral Forces-Resisting Element Irregularity)
Story = 4 Story

SDC = D

There isn't an in-plane offset of the lateral-forceresisting elements greater than the length of those

elements.

hence, In-Plane Discontinuity in Vertical lateral Forces-Resisting Element Irr. No Irregularity

Vertical Irregularities
Type 5a (Discontinuity in Lateral Strength-Weak Story Irregularity)
Story = 4 Story

SDC = D

There isn't any discontinuity in capacity

hence, Discontinuity in Lateral Strength-Weak Story Irregularity No Irregularity

Vertical Irregularities
Type 5b (Discontinuity in Lateral Strength-Extreme Weak Story Irregularity)
Story = 4 Story

SDC = D

There isn't any discontinuity in capacity

hence, Discontinuity in Lateral Strength-Extreme Weak Story Irregularity No Irregularity


Calculation Sheet
Vertical Irregularity of Structures
No. : 10-2533 Date : 02/11/2017

Project : ENI Design : Paa

Location : Timor Leste Checked : ASR

Building : Library Revision : A

Vertical Irregularities
Type 1a (Stiffness-Soft Story Irregularity)
Story = 2 Story Grid : 1.D

SDC = D

Y Sides

Story
Height Displacement Story-Drift Story-drift 0.8x(Story- 0.7x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 2.6634 2.6634 0.00052 0.00041 0.00036 - No

2 5150 6.3363 3.6729 0.00071 0.00057 0.00050 - No

Check :

1 0.70 1e
2e
1e

h1 h 2

0.00036 < 0.00071 Ok!

0.80 1e 2 e 1e 3e 2 e 4 e 3e
1 No Irregularity
2

h1 3 h2 h3 h4
0.00041 < - Ok!

Story = 3 Story Grid : 1.C

SDC = D

Y Sides

Story
Height Displacement Story-Drift
Story-drift 0.8x(Story- 0.7x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 3.6819 3.6819 0.00071 0.00057 0.00050 0.00070 No

2 5150 7.7605 4.0786 0.00079 0.00063 0.00055 - No


3 5150 10.8983 3.1378 0.00061 0.00049 0.00043 - No

Check :

1e
0.70 1e

1 2e

h1 h 2
0.00050 < 0.00079 Ok!

0.80 1e 2 e 1e 3e 2 e 4 e 3e
1 No Irregularity
2

h1 3 h2 h3 h4
0.00057 < 0.00070 Ok!

Story = 4 Story Grid : 1.B

SDC = D

Y Sides

Story
Height Displacement Story-Drift Story-drift 0.8x(Story- 0.7x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 3.5912 3.5912 0.00070 0.00056 0.00049 0.00068 No

2 5150 7.5397 3.9485 0.00077 0.00061 0.00054 0.00066 No

3 5150 10.5452 3.0055 0.00058 0.00047 0.00041 - No

4 3600 13.218 2.6728 0.00074 0.00059 0.00052 - No

Check :

1 0.70 1e
2e
1e

h1 h 2
0.00049 < 0.00077 Ok!

0.80 1e 2 e 1e 3e 2 e 4 e 3e
1 No Irregularity
2

h1 3 h2 h3 h4
0.00056 < 0.00068 Ok!

Vertical Irregularities
Type 1b (Stiffness-Extreme Soft Story Irregularity)
Story = 2 Story Grid : 1.D

SDC = D

Y Sides
Story
Height Displacement Story-Drift Story-drift 0.7x(Story- 0.6x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 2.6634 2.6634 0.00052 0.00036 0.00031 - No


2 5150 6.3363 3.6729 0.00071 0.00050 0.00043 - No
0 0 0 - - - - - -

0 0 0 - - - - - -

Check :

1 0.70 1e
2e
1e

h1 h 2
0.00031 < 0.00071 Ok!

No Irregularity
0.80 1e 2 e 1e 3e 2 e 4 e 3e
1
2

h1 3 h2 h3 h4
0.00036 < - Ok!

Story = 3 Story Grid : 1.C

SDC = D

Y Sides

Story
Height Displacement Story-Drift
Story-drift 0.7x(Story- 0.6x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 3.6819 3.6819 0.00071 0.00050 0.00043 0.00070 No

2 5150 7.7605 4.0786 0.00079 0.00055 0.00048 - No

3 5150 10.8983 3.1378 0.00061 0.00043 0.00037 - No

Check :

1e
0.70 1e

1 2e

h1 h 2
0.00043 < 0.00079 Ok!

No Irregularity
0.80 1e 2 e 1e 3e 2 e 4 e 3e
1
2

h1 3 h2 h3 h4
0.00050 < 0.00070 Ok!
Story = 4 Story Grid : 1.B

SDC = D

Y Sides

Story
Height Displacement Story-Drift Story-drift 0.7x(Story- 0.6x(Story- Avg. Story- Soft Story
Story Ratio drift Ratio) drift Ratio) drift Ratio Status
mm mm mm

0 0 0 0 0 0 0 0 -

1 5150 3.5912 3.5912 0.00070 0.00049 0.00042 0.00068 No

2 5150 7.5397 3.9485 0.00077 0.00054 0.00046 0.00066 No

3 5150 10.5452 3.0055 0.00058 0.00041 0.00035 - No

4 3600 13.218 2.6728 0.00074 0.00052 0.00045 - No

Check :

1e
0.70 1e

1 2e

h1 h 2
0.00042 < 0.00077 Ok!

No Irregularity
0.80 1e 2 e 1e 3e 2 e 4 e 3e
1
2

h1 3 h2 h3 h4
0.00049 < 0.00068 Ok!
1.44
Calculation Sheet
Horizontal Irregularity of Structures
No. : 10-2533 Date : 02/11/2017

Project : ENI Design : Paa

Location : Timor Leste Checked : ASR

Building : Library Revision : A

Horizontal Irregularities
Type 1a (Torsional Irregularity)
Story = 4 Story

SDC = D

x Sides
L R L R Ave. Max. Max./Ave. Torsional
Story
mm mm mm mm mm mm Ratio Status

0 0 0 0 0 0 0 0 No

1 4.13 4.0454 4.13 4.0454 4.0877 4.13 1.010 No

2 8.9048 8.7566 4.7748 4.7112 4.743 4.7748 1.007 No

3 12.9502 12.7597 4.0454 4.0031 4.02425 4.0454 1.005 No

4 15.6895 15.2689 2.7393 2.5092 2.62425 2.7393 1.044 No

Check :

Ratio Under limit

hence, Torsional Irregularity No irregularity

y Sides
L R L R Ave. Max. Max./Ave. Torsional
Story
mm mm mm mm mm mm Ratio Status

0 0 0 0 0 0 0 0 No

1 3.5912 3.8371 3.5912 3.8371 3.71415 3.8371 1.033 No

2 7.5397 7.9727 3.9485 4.1356 4.04205 4.1356 1.023 No

3 10.5452 11.1156 3.0055 3.1429 3.0742 3.1429 1.022 No

4 13.218 14.1485 2.6728 3.0329 2.85285 3.0329 1.063 No

Check :

Ratio Under limit


hence, Torsional Irregularity No irregularity

Horizontal Irregularities
Type 1b (Extreme Torsional Irregularity)
Story = 4 Story

SDC = D

x Sides
L R L R Ave. Max. Max./Ave. Torsional
Story
mm mm mm mm mm mm Ratio Status

0 0 0 0 0 0 0 0 No

1 4.13 4.0454 4.13 4.0454 4.0877 4.13 1.010 No

2 8.9048 8.7566 4.7748 4.7112 4.743 4.7748 1.007 No

3 12.9502 12.7597 4.0454 4.0031 4.02425 4.0454 1.005 No

4 15.6895 15.2689 2.7393 2.5092 2.62425 2.7393 1.044 No

Check :

Ratio Under limit

hence, Extreme Torsional Irregularity No irregularity

y Sides
L R L R Ave. Max. Max./Ave. Torsional
Story
mm mm mm mm mm mm Ratio Status

0 0 0 0 0 0 0 0 No

1 3.5912 3.8371 3.5912 3.8371 3.71415 3.8371 1.033 No

2 7.5397 7.9727 3.9485 4.1356 4.04205 4.1356 1.023 No

3 10.5452 11.1156 3.0055 3.1429 3.0742 3.1429 1.022 No

4 13.218 14.1485 2.6728 3.0329 2.85285 3.0329 1.063 No

Check :

Ratio Under limit

hence, Extreme Torsional Irregularity No irregularity

Horizontal Irregularities
Type 2 (Re-entrant Corner Irregularity)
Story = 4 Story
SDC = D

Re-entrant Re-entrant Re-entrant Ver. Length Re-entrant Re-entrant Re-entrant


Hor. Length Corner Corner
Story Corner Corner Corner Corner
m m Ratio Status m m Ratio Status

0 0 0 0 - 0 0 0 -

1 112.5 0 0.00% No 45 0 0.00% No

2 112.5 0 0.00% No 45 0 0.00% No

3 60 0 0.00% No 45 0 0.00% No

4 30 0 0.00% No 45 0 0.00% No

Ok Ok

Check :

Horizontal Sides Vertical Sides

Re-entrant Corner Irr. No Irregularity Re-entrant Corner Irr. No Irregularity

Horizontal Irregularities
Type 3 (Diaphragm Discontinuity Irregularity)
Story = 4 Story

SDC = D

Gross Area Openings Diaph. Diaph.


Diaph.
Story Discontinuity Discontinuity
Ratio Status
m2 m2

0 0 0 0 -

1 5062.5 2499.94 49.38% No

2 5062.5 1129.69 22.31% No

3 2700 0 0.00% No

4 435 0 0.00% No

Ok

Check :

Diaphragm Discontinuity Irregularity No Irregularity

Horizontal Irregularities
Type 4 (Out-of-Plane Offset Irregularity)

Story = 4 Story

SDC = D
There are no discontinuities in a lateral force path.

hence, Out-of-plane Offset Irregularity No Irregularity

Horizontal Irregularities
Type 5 (Nonparallel System Irregularity)
Story = 4 Story

SDC = D

The vertical lateral-force-resisting elements are parallel to or symmetric about the major orthogonal

axes of the building's lateral-force-resisting system

Example :

The vertical lateral-foree-resisting frame elements located on line 1.16 are parallel to the major

orthogonal axes of the building (i.e., lines 1.A and 1.1).

hence, Nonparallel System Irregularity No Irregularity