Hydrocarbon Treating
Hydrocarbon Treating
21-1
Nomenclature
A = Area ft2 R = volume of hydrocarbon feed (gal./batch)
a = caustic solution activity S = total percentage of caustic which is spent
FA = fraction of acid absorbed STP = standard temperature and pressure
FPS = feet per second T = absolute temperature
GPM = gallons per minute TLV = threshold limit value
H = Henry's constant for component, psi/gmol/L V = caustic system inventory (gal.)
pH = 12 pH = 12
amine solution = 5000 gal amine solution = 5000 gal
OHconc- for pH 12 = 1.00E-02 gmol/L OHconc - for pH 12 = 1.00E-02 gmol/L
OH conc
-
for pH 7 = 1.00E-07 gmol/L OHconc- for pH 7 = 1.00E-07 gmol/L
MWHCl = 36.5 g/gmol MWHCl = 36.5 g/gmol
Conversions: Conversions:
To determine the total requirement of HCl To determine the total requirement of HCl
HClamount = 1.9E4 1.00E-2 = 190 gmol HClamount = 1.9E4 1.00E-2 = 190.0 gmol
The sample calculations, equations and spreadsheets presented herein were developed using examples published in the Engineering Data Book as published by the Gas Processor Suppliers Association as a service to the gas processing industry. All information and calculation formulae has been compiled and edited in cooperation with Gas Processors Association (GPA).
While every effort has been made to present accurate and reliable technical information and calculation spreadsheets based on the GPSA Engineering Data Book sample calculations, the use of such information is voluntary and the GPA and GPSA do not guarantee the accuracy, completeness, efficacy or timeliness of such information. Reference herein to any specific commercial product, calculation method, process, or service by trade-name, trademark, and service mark manufacturer or otherwise does not constitute or imply endorsement, recommendation or favoring by the GPA and/or GPSA.
The Calculation Spreadsheets are provided without warranty of any kind including warranties of accuracy or reasonableness of factual or scientific assumptions, studies or conclusions, or merchantability, fitness for a particular purpose or non-infringement of intellectual property.
In no event will the GPA or GPSA and their members be liable for any damages whatsoever (including without limitation, those resulting from lost profits, lost data or business interruption) arising from the use, inability to , reference to or reliance on the information in thes Publication, whether based on warranty, contract, tort or any other legal theory and whether or not advised of the possibility of such damages.
These calculation spreadsheets are provided to provide an Operational level of accuracy calculation based on rather broad assumptions (including but not limited to; temperatures, pressures, compositions, imperial curves, site conditions etc) and do not replace detailed and accurate Design Engineering taking into account actual process conditions, fluid properties, equipment condition or fowling and actual control set-point dead-band limitations.
Example 21-2 -- 30.0 MMscfd of gas available at 850 psig and containing 0.6% Application 21-2 -- 30.0 MMscfd of gas available at 850 psig and containing
H2S and 2.8% CO2 is to be sweetened using 20%, by weight, DEA solution. If a 0.6% H2 S and 2.8% CO2 is to be sweetened using 20%, by weight, DEA
conventional DEA system is to be used, what amine circulation rate is required, solution. If a conventional DEA system is to be used, what amine circulation
and what will be the principal parameters for the DEA treating system? rate is required, and what will be the principal parameters for the DEA treating
system?
To determine solution circulation for DEA To determine solution circulation for DEA
To determine Reboiler heat duty and area To determine Reboiler heat duty and area
To determine Rich-Lean amine exchanger heat duty and area To determine Rich-Lean amine exchanger heat duty and area
Qrle = 45000 GPM Fig 21-14 Qrle = 45000 GPM Fig 21-14
Arle = 11.25 GPM Fig 21-14 Arle = 11.25 GPM Fig 21-14
To determine Amine Cooler heat duty and area To determine Amine Cooler heat duty and area
Qac = 15000 GPM Fig 21-14 Qac = 15000 GPM Fig 21-14
Aac = 10.2 GPM Fig 21-14 Aac = 10.2 GPM Fig 21-14
To determine Reflux Condenser heat duty and area To determine Reflux Condenser heat duty and area
Qrc = 30000 GPM Fig 21-14 Qrc = 30000 GPM Fig 21-14
Arc = 5.2 GPM Fig 21-14 Arc = 5.2 GPM Fig 21-14
To determine Main amine pump power To determine Main amine pump power
HPmap = GPM P 0.00065 Fig 21-15 HPmap = GPM P 0.00065 Fig 21-15
To determine Amine booster pump power To determine Amine booster pump power
HPabp = GPM 0.06 Fig 21-15 HPabp = GPM 0.06 Fig 21-15
HPrp = GPM 0.06 Fig 21-15 HPrp = GPM 0.06 Fig 21-15
HPac = GPM 0.36 Fig 21-15 HPac = GPM 0.36 Fig 21-15
To determine Diameter of Regenrator Below Feed Point To determine Diameter of Regenrator Below Feed Point
To determine Diameter of Regenerator Above Feed Point To determine Diameter of Regenerator Above Feed Point
GPM of DEA solution = 45 [3 (3.4/20)] = 230 gpm GPM of DEA solution = 45 [3 (3.4/20)] = 230 gpm
Qrle = 45000 230 = 1.03E+07 Btu/hr Qrle = 45000 230 = 1.03E+07 Btu/hr
Arle = 11.25 230 = 2590 ft2 Arle = 11.25 230 = 2590 ft2
Qac = 15000 230 = 3.44E+06 Btu/hr Qac = 15000 230 = 3.44E+06 Btu/hr
Aac = 10.2 230 = 2350 ft2 Aac = 10.2 230 = 2350 ft2
Qrc = 30000 230 = 6.9E+06 Btu/hr Qrc = 30000 230 = 6.9E+06 Btu/hr
Arc = 5.2 230 = 1200 ft2 Arc = 5.2 230 = 1200 ft2
HPmap = 230 850 0.00065 = 127 hp HPmap = 230 850 0.00065 = 127 hp
The sample calculations, equations and spreadsheets presented herein were developed using examples published in the Engineering Data Book as published by the Gas Processor Suppliers Association as a service to the gas processing industry. All information and calculation formulae has been compiled and edited in cooperation with Gas Processors Association (GPA).
While every effort has been made to present accurate and reliable technical information and calculation spreadsheets based on the GPSA Engineering Data Book sample calculations, the use of such information is voluntary and the GPA and GPSA do not guarantee the accuracy, completeness, efficacy or timeliness of such information. Reference herein to any specific commercial product, calculation method, process, or service by trade-name, trademark, and service mark manufacturer or otherwise does not constitute or imply endorsement, recommendation or favoring by the GPA and/or GPSA.
The Calculation Spreadsheets are provided without warranty of any kind including warranties of accuracy or reasonableness of factual or scientific assumptions, studies or conclusions, or merchantability, fitness for a particular purpose or non-infringement of intellectual property.
In no event will the GPA or GPSA and their members be liable for any damages whatsoever (including without limitation, those resulting from lost profits, lost data or business interruption) arising from the use, inability to , reference to or reliance on the information in thes Publication, whether based on warranty, contract, tort or any other legal theory and whether or not advised of the possibility of such damages.
These calculation spreadsheets are provided to provide an Operational level of accuracy calculation based on rather broad assumptions (including but not limited to; temperatures, pressures, compositions, imperial curves, site conditions etc) and do not replace detailed and accurate Design Engineering taking into account actual process conditions, fluid properties, equipment condition or fowling and actual control set-point dead-band limitations.
LIMITS
Calculation results diameters are for vessel INSIDE diameter