STIFF (Version 1)
STIFF (Version 1)
Ireq =
1.5 x d3 x t3 / c2
=
1.5 x (1210 ^3)x(14^3)/(1815)^3
=
2E+06 mm4
Outstand of each stiffener not more than-1 = 120
TRAIL SECTION = 120 x 10 mm Full Depth
120
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Say 3 No.s
PROVIDE SIFFENERS - 03 Equal spacings 1666.67 mm
JOB NO 1247 DATE 5/3/2011
JOB NAME TATA IRON & STEEL CO. LTD. DESGN BY BMK
TITLE DESIGN OF INTERMEDIATE STIFFENER REV NO 0
CHKD MDP BUILDING Err:522
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1172 ^3)x(10^3)/(1500)^3
= 1E+06 mm4
150
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1160 ^3)x(12^3)/(1500)^3
= 2E+06 mm4
150
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
### x 16 mm flats
400 400
I = 16 x ( 2x265+20)^3/12+ ( 400x2-16)x20^3/12
2.22E+08 mm^4
24480 mm^2
r = Sqrt( I / A)
= 95.31 mm
### x 16 mm flats
160 160
I = 16 x ( 2x121+8)^3/12+ ( 160x2-16)x8^3/12
20846304 mm^4
6432 mm^2
r = Sqrt( I / A)
= 56.93 mm
### x 10 mm flats
160 160
I = 10 x ( 2x108.5+8)^3/12+ ( 160x2-10)x8^3/12
9505414 mm^4
4730 mm^2
r = Sqrt( I / A)
= 44.83 mm
85 x 14 mm flats
120 120
I = 14 x ( 2x84.5+6)^3/12+ ( 120x2-14)x6^3/12
6256672 mm^4
3806 mm^2
r = Sqrt( I / A)
= 40.55 mm
### x 24 mm flats
320 320
I = 24 x ( 2x242+16)^3/12+ ( 320x2-24)x16^3/12
2.5E+08 mm^4
21856 mm^2
r = Sqrt( I / A)
= 107.00 mm
### x 32 mm flats
480 480
I = 32 x ( 2x288+24)^3/12+ ( 480x2-32)x24^3/12
5.77E+08 mm^4
41472 mm^2
r = Sqrt( I / A)
= 117.96 mm
### x 40 mm flats
640 640
I = 40 x ( 2x284+32)^3/12+ ( 640x2-40)x32^3/12
7.23E+08 mm^4
63680 mm^2
r = Sqrt( I / A)
= 106.58 mm
WIND -COLUMN
COLUMN SECTION:
Length ( L ) 17300 mm
Web Depth:(d) 750 mm
Web Thickness(t) 8 mm
Flange Width: 270 mm
Flange Thickness: 12 mm
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (750 ^3)x(8^3)/(1000)^3
= 324000 mm4
75
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
CRANE -COLUMN
COLUMN SECTION:
Length ( L ) 8880 mm
Web Depth:(d) 600 mm
Web Thickness(t) 8 mm
Flange Width: 250 mm
Flange Thickness: 10 mm
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (600 ^3)x(8^3)/(750)^3
= 294912 mm4
100
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1150 ^3)x(14^3)/(1000)^3
= 6E+06 mm4
150
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1650 ^3)x(16^3)/(1000)^3
= 3E+07 mm4
225
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1000 ^3)x(6^3)/(1500)^2
= 144000 mm4
75
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (492 ^3)x(6^3)/(700)^2
= 78749 mm4
75
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1390 ^3)x(10^3)/(2000)^2
= 1E+06 mm4
100
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (450 ^3)x(6^3)/(650)^2
= 69880 mm4
75
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1000 ^3)x(10^3)/(750)^2
= 3E+06 mm4
75
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Not Suffucient
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (890 ^3)x(10^3)/(750)^2
= 2E+06 mm4
100
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (696 ^3)x(6^3)/(1000)^2
= 109238 mm4
75
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (900 ^3)x(6^3)/(762)^2
= 406783 mm4
75
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1000 ^3)x(8^3)/(1500)^2
= 341333 mm4
100
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (2600 ^3)x(20^3)/(2000)^2
= 5E+07 mm4
250
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
Ireq = 1.5 x d3 x t3 / c2
= 1.5 x (1490 ^3)x(10^3)/(2000)^2
= 1E+06 mm4
125
Hence the moment of Inertia of the provided section (I available)is more than the
required (Ireq).Hence The provided section is Ok
4.0
9.65
k1 = 1
k2 = 0.93
k3 = 1
= 95.00 m2