LC1 - LC3 - LC2 - LC4 - LC5 - at The Base: Based On Section 203.3 of NSCP 2015 7th Edition

This document summarizes load combinations and design forces for two structural members, a column (Member 1) and rafter (Member 2), based on the NSCP 2015 7th edition code. It provides the axial and moment loads for each member under different load combinations involving dead, live, and rain load effects. Load Combination 5 governs the design of both members, with the column experiencing higher design forces than the rafter.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
444 views1 page

LC1 - LC3 - LC2 - LC4 - LC5 - at The Base: Based On Section 203.3 of NSCP 2015 7th Edition

This document summarizes load combinations and design forces for two structural members, a column (Member 1) and rafter (Member 2), based on the NSCP 2015 7th edition code. It provides the axial and moment loads for each member under different load combinations involving dead, live, and rain load effects. Load Combination 5 governs the design of both members, with the column experiencing higher design forces than the rafter.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Applicable Load Combinations using Strength Design or Load and Resistance Factor Design

based on Section 203.3 of NSCP 2015 7th edition

Load Combinations

LC1 - 1.4DL LC3 - 1.2DL + 1.0WL + 0.5Lr


LC2 - 1.2DL + 1.6Lr +0.5W LC4 - 0.9D + 1.0W
LC5 - 0.9D - 1.0W
DESIGN FORCES - COLUMN (Member 1)
At the base
Axial (kN)
Axial P Load Combination
DL Lr WL LC1 LC2 LC3 LC4 LC5
22.31 30.92 -42.81 31.23 54.84 -0.58 -22.73 62.89

Moment (kN-m)
Loads Load Combination
DL Lr WL LC1 LC2 LC3 LC4 LC5
19.83 59.49 -200.99 27.76 18.49 -147.45 -183.14 218.84

At the top
Axial (kN)
Axial P Load Combination
DL Lr WL LC1 LC2 LC3 LC4 LC5
10.31 30.92 -42.81 14.43 40.44 -14.98 -33.53 52.09

Moment (kN-m)
Loads Load Combination
DL Lr WL LC1 LC2 LC3 LC4 LC5
29.23 87.68 -136.82 40.92 106.95 -57.90 -110.51 163.13

DESIGN FORCES - RAFTER (Member 2)

Axial (kN)
Loads Load Combination
DL Lr WL LC1 LC2 LC3 LC4 LC5
7.26 21.78 -21.33 10.16 32.90 -1.73 -14.80 27.86

Moment (kN-m)
Loads Load Combination
DL Lr WL LC1 LC2 LC3 LC4 LC5
29.23 87.68 -136.82 40.92 106.95 -57.90 -110.51 163.13

Based on the FBD's shown, member 1 governs the design of the column, while member 2 governs
the design of the rafter. Member 4 will adopt the design of member 1 and member 3 will adopt the
design of member 2. Load Combination 5 govens for both members.