Data Sheet
Data Sheet
operating guide
1Wiring diagram
Figure Figure
for example:
As for 5V ADthe maximum rms voltage of
the transformer: Umax = 5V / 2 =3.53V
As for 0~3.3V ADthe maximum rms voltage of
the transformer: V max = 3.3V / 2 2 =1.16V
Current-limiting resistor R= V
I
VRated input voltage
I Rated operating current when Coil
resistance is compared with current-limiting
resistor R , it can be ignored.
ZMPT101B/ZMPT107 usually working at rated
current:1~2mA. When Rated input
voltage100V Usually choosing the operating
current I=2mA; When Rated input
voltage220VTo reducing the resistor power
Usually choosing the operating current 1 mA
I2 mA.
for example: V=100VI=2 mA
R= V =50K
I
for example: V=220VI=1.1mA
R= V =200 k
I
To improve reliability, the current-limiting
resistor selected usually is greater than its
4times the rated power, and generally use a high
temperature coefficient metal film resistor.
R=
V outputmax
=
Voutputmax
R
I Vinputmax
for example: Voutput max =3.53V Vinput max =120V R =50 k
R= 3.53 50 k =1.471 k
120
Directions:
(1) Above formula is also suitable for the two
ways of active and passive output .
(2)when selecting the sampling resistorResistor
should not exceed : Voutput max R / Vinput max
(2)Passive output
AdvantageSimple circuitHigh precision.
Disadvantage The output voltage has certain
limitations The greater the load
resistance, the greater the phase
difference