0% found this document useful (0 votes)
632 views4 pages

COMPACT 99B Inlet Valve Manual

This document provides installation instructions for several inlet valve models, including the Robeco 06, Standard 15 EL, Compact 95L/93L, Compact 99B, Handy 93B, and others. It describes how to properly place and secure each valve through the inlet hole, connect the water supply, and adjust the water level using the adjusting screw. Warnings are provided to not overtighten connections and to ensure a tight seal using the appropriate gaskets or seals.

Uploaded by

alwill09
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
632 views4 pages

COMPACT 99B Inlet Valve Manual

This document provides installation instructions for several inlet valve models, including the Robeco 06, Standard 15 EL, Compact 95L/93L, Compact 99B, Handy 93B, and others. It describes how to properly place and secure each valve through the inlet hole, connect the water supply, and adjust the water level using the adjusting screw. Warnings are provided to not overtighten connections and to ensure a tight seal using the appropriate gaskets or seals.

Uploaded by

alwill09
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

GB

N 50
INLET VALVES

4, quai Antoine 1er / BP 219 / MC 98007 MONACO Cedex


Tl. 00 377 93 15 53 75 / Fax : 00 377 92 05 71 04 / E-mail: [email protected]

Siamp UK Ltd / Unit C2 / Meadowbank Business Park


Tweedale Way / Hollinwood / Oldham / Greater Manchester / OL9 8EH
Telephone : 0161 681 2120 / Fax : 0161 681 2130 / [email protected]
On 99B and 95L inlets, an approved single check valve or some other no less effective
backflow prevention device shall be fitted at the point of connection(s) between the supply
and the fitting.

ROBECO 06 and STANDARD 15 EL Fibre Seal


Adjusting screw
Place inlet valve
through inlet hole
Secure with backnut
Connect the supply
Adjust water level Introduce
float arm Backnut
with adjusting screw.

N.B.: Make connecting


tightness with fibre seal
other than any corrosive joint
compound

COMPACT 95L/93L MAINTENANCE


Adjusting screw
Joint ring
Backnut

Membrane
Filtre

Fibre seal

Membrane

Place inlet valve through inlet hole


Secure with backnut
Connect the supply
Adjust water level
with grey adjusting screw.
N.B.: Make connecting tightness with
fibre seal other than any corrosive
joint compound
COMPACT 99B
Adjusting screw Place inlet valve through inlet hole with inlet
rubber washer inside the cistern
Secure with backnut
Connect the supply
Adjust water level
with grey adjusting screw.
N.B. Ensure tightness of connection to cistern with
filter gasket.
WARNINGS:
1 - Do not overtight in any case.
Inlet 2 - Do not use any sealing paste and/or compound
rubber in any case
washer Backnut SIAMP will be not responsible in case these
Filter seal warnings are not respected.

COMPACT 99B with telescopic tube


Adjust telescopic tube
(a) raise the grey blocking ring
(b) screw or unscrew the gradiated tube
Blocking ring in way so that the inlet top not exceed
the top of the tank
(c) position back the grey ring
Place inlet valve through inlet hole with inlet
(a)
rubber washer inside the cistern
(c) Secure with backnut
Connect the supply
Adjust water level
(b) Adjusting screw with grey adjusting screw.
N.B. Ensure tightness of connection to cistern with
filter gasket.

WARNINGS:
1 - Do not overtight in any case.
2 - Do not use any sealing paste and/or compound
in any case
Inlet
rubber SIAMP will be not responsible
washer Backnut
in case these warnings are not respected.
Filter seal
Adjusting screw

HANDY 93B
Place inlet valve through inlet
hole with inlet rubber washer
inside the cistern
Secure with backnut
Connect the supply
Adjust water level
with grey adjusting screw. Inlet
rubber
N.B.: Make connecting tightness washer
with fibre seal other than any
corrosive joint compound Backnut Fibre seal

HANDY 93B with telescopic tube Adjusting screw

Blocking ring

Inlet
rubber
(a) washer
(c)

Backnut
(b) Fibre seal

Adjust telescopic tube (a) raise the grey blocking ring, (b) screw or unscrew the
gradiated tube in way so that the inlet top not exceed the top of the tank, (c)
position back the grey ring
Place inlet valve through inlet hole with inlet rubber washer inside the cistern
Secure with backnut
Connect the supply
Adjust water level with grey adjusting screw.
N.B.: Make connecting tightness with fibre seal other than any corrosive joint
compound

For all inlet valves : manually screw the backnut until it is in contact with the ceramic. If necessary give an extra quarter
turn (maximum).
Rf. 50 5455 00B

N.B.: Excessive tightening can damage the valve and would not be covered by the guarantee. Ensure tightness of connection
to cistern with filter gasket.
SIAMP will be not responsible in case these warnings are not respected.
N.B.: In the tank, do not use any anti limescale products or chlorine based products which could damage the mechanism
and would not be covered by the guarantee.