Fluke 117 Datasheet

The Fluke 117 is a compact true-rms multimeter for commercial applications that includes integrated non-contact voltage detection. It measures voltage, current, resistance, frequency and capacitance with features like AutoVolt, LoZ mode, and min/max/average recording. The meter is CAT III 600V rated with accuracy specifications listed for each measurement function.

Uploaded by

João Almeida
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views

Fluke 117 Datasheet

The Fluke 117 is a compact true-rms multimeter for commercial applications that includes integrated non-contact voltage detection. It measures voltage, current, resistance, frequency and capacitance with features like AutoVolt, LoZ mode, and min/max/average recording. The meter is CAT III 600V rated with accuracy specifications listed for each measurement function.

Uploaded by

João Almeida
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.

com

Fluke 117
Electricians Multimeter
with Non-Contact Voltage
Technical Data

Compact true-rms meter for


commercial applications
The Fluke 117 is the ideal meter for
demanding settings like commercial
buildings, hospitals and schools. The 117
includes integrated non-contact voltage
detection to help get the job done faster.

Features include:
VoltAlert technology for non-contact voltage detection
AutoVolt automatic ac/dc voltage selection
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True-rms for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30 seconds)
Resistance, continuity, frequency and capacitance
Min/Max/Average to record signal fluctuations
Compatible with optional magnetic hanger (ToolPak) for
hands free operation
CAT III 600 V safety rated

General specifications
Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 C to 28 C, with relative humidity at
0 % to 90 %.
The accuracy specifications take the form of:
( [ % of reading ] + [ counts ] )
Maximum voltage between any 600 V
terminal and earth ground
Surge protection 6 kV peak per IEC 61010-1 600 V
Actual size CAT III, Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse
(Fluke PN 803293)
Display Digital: 6,000 counts, updates 4/sec
Bar graph 33 segments, updates 32/sec
Operating temperature -10 C to + 50 C
Storage temperature -40 C to + 60 C
Battery 9 volt Alkaline, NEDA 1604A/
R
IEC 6LR61
N10140
Battery life 400 hours typical, without backlight
Accuracy specifications
Measurement Range Resolution Accuracy ([% of reading] + [counts])
Ordering
DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 information
DC volts 6.000 V 0.001 V
60.00 V 0.01 V 0.5 % + 2 Fluke-117 Electricians
600.0 V 0.1 V Multimeter with
Non-Contact Voltage
Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) Included
TL75 Test leads, holster, Users
AC millivolts1 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
true-rms 2.0 % + 3 (500 Hz to 1 kHz) manual and 9 V battery (installed).
AC volts1 true-rms 6.000 V 0.001 V
1.0 % + 3 (45 Hz to 500 Hz)
60.00 V 0.01 V
2.0 % + 3 (500 Hz to 1 kHz)
600.0 V 0.1 V
Continuity 600 1 Beeper on < 20 off > 250 ; detects
opens or shorts of 500 s or longer.
Ohms 600.0 0.1 0.9 % + 2
6.000 k 0.001 k
60.00 k 0.01 k
0.9 % + 1
600.0 k 0.1 k
6.000 M 0.001 M
40.00 M 0.01 M 1.5 % + 2
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF 1 nF
10.00 F 0.01 F 1.9 % + 2
100.0 F 0.1 F
9999 F 1 F
100 F to 1000 F 1.9 % + 2
> 1000 F 5 % + 20
Lo-Z capacitance 1 nF to 500 F 10 % + 2 typical
AC amps true-rms 6.000 A 0.001 A
(45 Hz to 500 Hz) 1.5 % + 3
10.00 A 0.01 A
20 A overload for 30 seconds max.
DC amps 6.000 A 0.001 A
1.0 % + 3
10.00 A 0.01 A
20 A overload for 30 seconds max.
Fluke. Keeping your world
Hz (V or A input)2 99.99 Hz 0.01 Hz up and running.
999.9 Hz 0.1 Hz
0.1 % + 2
9.999 kHz 0.001 kHz
50.00 kHz 0.01 kHz
Notes:
1 All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.

Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-
zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of 3
at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.

 Fluke Corporation 117 Electricians Multimeter with Non-Contact Voltage