100% found this document useful (8 votes)
4K views

QCD Firefighting Exam Question

This document contains 25 multiple choice questions for a fire fighting QCD exam. The questions cover topics like fire pump components, required separation distances, equipment labeling standards, valve types, pump sizing, and maintenance tagging requirements. Correct answers are provided for definitions of listed, AHJ, and shall. Questions also address topics like pump sizing limits, end suction pump configuration, motor sizing, spare sprinkler requirements, and codes for clean agent systems.

Uploaded by

RATHAKRISHNAN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (8 votes)
4K views

QCD Firefighting Exam Question

This document contains 25 multiple choice questions for a fire fighting QCD exam. The questions cover topics like fire pump components, required separation distances, equipment labeling standards, valve types, pump sizing, and maintenance tagging requirements. Correct answers are provided for definitions of listed, AHJ, and shall. Questions also address topics like pump sizing limits, end suction pump configuration, motor sizing, spare sprinkler requirements, and codes for clean agent systems.

Uploaded by

RATHAKRISHNAN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FireFightingQCDExamQuestions

Totalquestion:25
Time:90Minutes
PassMark:70%&above
1.DrawFireFightingRaiserDiagramandmark20pointsof2b+G+10HighRaiseBuilding
2.MinimumrequiredseparationdistanceofnonfireratedconstructionPumproomfromBuilding.(50
ft)
3.RangeofmeasuringinstrumenttocomparewithPumprating(Double)
4.whatistheuseofvalveusedsuctionlineofJockeyPump(Isolation)
5..PressuregaugeusedtocheckPumpPerformance(New&Calibrated)
6.MinimumcalibrationperiodofPressureGauge(1Year)
7...:Equipment,materials,orservicesincludedinalistpublishedbyan
Organizationthatisacceptabletotheauthorityhavingjurisdictionandconcernedwith
Evaluationofproductsorservices,thatmaintainsperiodicinspectionofproductionoflisted
Equipmentormaterialsorperiodicevaluationofservices,andwhoselistingstatesthat
Eithertheequipment,material,orservicemeetsappropriatedesignatedstandardsorhas
Beentestedandfoundsuitableforaspecifiedpurpose.(Listed)
8isAnorganization,office,orindividual
Responsibleforenforcingtherequirementsofacodeorstandard,orforapproving
Equipment,materials,aninstallation,oraprocedure.(AHJ)
9Indicatesamandatoryrequirement.(Shall)
10..isAnautomaticvalveinstalledonthedischargesideofapositive
Displacementpumptorelievepressurepriortothepumpdriverreachingoperatingspeed.(
DumpValve.)
11.Adevicethatallowsthediversionofliquidtolimitexcesspressure
inasystem(ReliefValve)
12.Pipewithfilledwatercapacitytakingforseismicdesign(5Times)
13.Drainconnectionrequiredfor4StandPipe(2)
14.Equipmentormaterialstowhichhasbeenattachedalabel,symbol,orother
identifyingmarkofanorganizationthatisacceptabletotheauthorityhavingjurisdiction
andconcernedwithproductevaluation,thatmaintainsperiodicinspectionofproductionof
labeledequipmentormaterials,andbywhoselabelingthemanufacturerindicates
compliancewithappropriatestandardsorperformanceinaspecifiedmanner(Labled)
15.Apilotoperatedvalveinstalledindischargepiping
thatmaintainspositivepressureinthesuctionpiping,whilemonitoringpressureinthe
suctionpipingthroughasensingline.(LowSuctionThrottlingValve.)
16.Avalvethatisdesignedtorelieveexcessflowbelowpump
capacityatsetpumppressure.(UnloaderValve.)
17.Acentrifugalfirepumpforfireprotectionshallbeselectedtooperateatlessthanor
equaltopercentoftheratedcapacity.(150%)
18.Asinglesuctionpumphavingitssuctionnozzleonthe
oppositesideofthecasingfromthestuffingboxandhavingthefaceofthesuctionnozzle
perpendiculartothelongitudinalaxisoftheshaft.(EndSuctionPump.)
19.Themotorcapacityinhorsepowershallbesuchthatthemaximummotorcurrentin
anyphaseunderanyconditionofpumploadandvoltageunbalanceshall..the
motorratedfullloadcurrentmultipliedbytheservicefactor.(notexceed)
20.Eachfireextinguishershallhaveatagorlabel
securelyattachedthatindicatesthe(monthandyearthemaintenancewas
performed,thepersonperformingthework,nameoftheagencyperforming
thework)
21.CodeusedforCleanAgentFireExtinguishingSystems(NFPA2001)
22.Minimumnumberofsparesprinklerrequiredsprinklerinthesystemhaving250Nos
sprinkler(Atleast6Nos)
23.SprinklerBulbcolorforExtraHighHazardzone(Purple)
24. The maximum service factor at which a motor shall be used is..(1.15)
25. The horsepower capability of the engine, when equipped for fire pump service,
shall not be less than percent greater than the listed horsepower on the engine
nameplate.(10%)