Level Switches Cat912
Level Switches Cat912
com
Request Quote
Level Switches
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 1/48
Level Switches Features and Benefits
Standard Chamber Materials All SOR level switch chambers are constructed using
ASTM grade materials with full material certification. Mill Test Reports are kept on file for all raw
materials. Copies are available upon request at the time of order placement.
Carbon Steel Construction Chamber Center Section...........................................A106 Grade B
Flanges/Weld Fittings...................................................................A105
Weld Cap............................................................................. A234-WPB
Studs/Nuts............................................................. A193-B7/A194-2H
Stainless Steel Construction Chamber Center Section................................... A312-TP316/316L
Flanges/Weld Fittings...............................................A182-316/316L
Weld Cap.....................................................................A403-316/316L
Studs/Nuts............................................................. A193-B7/A194-2H
Quality Assurance
SOR maintains a high level of quality throughout our corporation. Many quality assurance features
are built into our products.
ISO 9001 certified engineering design and production system (certified since 1993).
Level-welded chambers designed to the guidelines of ASME B31.1 and B 31.3
(inspection certificate available see page 29).
All welders and weld procedures are qualified and maintained to ASME Section IX.
All ASTM grade materials used - Certified Mill Test Reports required on all raw materials.
Switching Mechanisms
SOR switching mechanisms are designed for use in punishing industrial conditions.
All stainless steel construction - no aluminum or brass.
Temperature ratings available from -65F (54C) to 1000F (538C) on dry, noncondensing
services.
Condensing service (steam) temperature ratings available up to 800F (427C), and up to
1200F (649C) with protection (see page 26).
Available switching mechanisms include hermetically sealed, standard open contacts, or
pneumatic contacts.
Agency listings are available on most switch mechanisms: UL, CSA, ATEX or IECEx.
Gaskets
All standard models are provided with a Nitrile binder composite gasket that is selected for its
resistance to hydrocarbons and steam.
For high-temperature, high-pressure or NACE-constructed units, a spiral-wound gasket is used
with 316SS wound-around Grafoil.
Extreme high-pressure model 802 uses a soft-iron, ring-joint gasket on the chamber head flange.
Internal Trim
All sensing elements (floats and displacers) are constructed of either 316/316LSS or porcelain
as a minimum.
Attraction sleeves are available in 400SS as a standard, with 316/316LSS or other exotic
metals as an option.
All other wetted internal parts are 316SS or better. Displacer springs are made of Inconel 600.
Product Support
SOR has a full-time engineering staff dedicated to solving your mechanical level switch problems.
Engineers and technicians are knowledgeable about sales and production techniques, and are
dedicated to providing the best solution to our customers at the best price.
2/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches Table of Contents
Section Page
Principles of Operation.................................................................................4
Model Tree.........................................................................................................6
Step 1a: Float or Displacer & Model Series................................... 7
Step 1b: Pressure Rating and Specific Gravity............................. 8
Step 2: Chamber/Process Connection Material........................ 14
Step 3: Process Connection........................................................... 15
Step 4: Trim Material......................................................................... 18
Step 5: Switching Mechanism........................................................ 19
Step 6: Housing................................................................................. 22
Step 7: Accessories/Certificates................................................... 23
High Temperature Selection.................................................................... 25
Manual Check (MC) & True Check (TC) Options............................... 28
Examination and Testing Requirements.............................................. 29
ASTM Material Designations.................................................................... 30
Weights............................................................................................................ 31
Specific Gravity of Water........................................................................... 32
Dimensions
100 Series............................................................................................ 33
200 Series............................................................................................ 35
108/208 Models................................................................................. 37
300 Series............................................................................................ 38
400 Series............................................................................................ 39
741-743, 802 Models........................................................................ 40
740, 804 Models................................................................................ 42
700 Series............................................................................................ 44
730 Series............................................................................................ 45
750 Series............................................................................................ 46
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 3/48
Level Switches Principles of Operation
Rising liquid level lifts the float, sliding the attraction Pivot
sleeve up inside the enclosing tube and into the Bias Spring
Switching Switching
Element Element
Actuated C Common Deactuated C Common
Magnetic NC Normally Closed NC Normally Closed
Magnetic
Field NO Normally Open NO Normally Open
Field
Engaged
Disengaged
Level
Differential
Actuated Deactuated
4/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches Principles of Operation
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 5/48
Level Switches How to Order
How to Order
Below is the SOR quick select model number tree that provides you with options to configure and
order a product for your application.
You must select a designator for each component (see corresponding pages)
Reference tables, charts and additional information are provided throughout the catalog to
help you make your selections.
4 Trim Material
B 316/316L SS Float/Displacer Material
400
SS Attraction Sleeve
C 316/316L
SS Float/Displacer Material & Attraction Sleeve
m Monel
400 Float/Displacer Material & Attraction Sleeve
f 321 SS Float Material
400
SS Attraction Sleeve
Process Connection 3 g 321 SS Float/Displacer Material
316/316L SS Attraction Sleeve
See Pages 15-17 for selection information XXX p Porcelain Displacer Material
400 SS Attraction Sleeve
r Porcelain Displacer Material
316/316L
SS Attraction Sleeve
Connection Material
Carbon Steel
316/316L Stainless Steel
A
C
5 Switching Mechanism
XX See Pages 19-21 for selection information
See Page 14 for more information
Model 1 6 Housing
XX See Page 22 for selection information
See Pages 7-13 for XXX
selection information
Model Selection
is broken into
two steps: 1a & 1b
7 Accessories
XX See Page 23-25 for selection information
First, determine which XX Multiple Accessories can be selected
model series is needed.
Then, go to the associated
page to select the model
number designator based
on pressure and specific
gravity rating.
6/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 1a: Model Selection
FLOAT or DISPLACER 1a
The first step to creating your model number is to determine whether a float or a displacer-based
level switch is needed. See below for the different options for selecting the right technology for
a specific application.
108, 208 Horizontal float switch designed 700 Series Used for high alarm or level control
Steam specifically to handle high Single-Stage through adjustable wide differential
Condensate temperature/pressure Top Insertion option
External Low SG capabilities Mount Displacer Direct tank mount
Chamber Steam applications Switch (p. 12)
Float Switch Serviceable/Non-serviceable
(p. 9) options 730 Used for high-high, high-low, and
Dual-Stage low-low level alarms
300 Series Quick and easy installation; direct Direct tank mount
mount Top Insertion
Top Insertion Mount Displacer
Mount Float Low Cost Solution
Used for high level alarm/overfill Switch (p. 12)
Switch (p. 10)
protection 750 Three switching points to provide
400 Series Quick and easy installation; direct Triple-Stage numerous combinations of ways
mount Top Insertion to configure the point level switch
Side Insertion
Mount Used for specific point level Mount Displacer outputs
Float indication Switch (p. 13) Direct tank mount
Switch Can be installed at any height of
(p. 10) the tank
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 7/48
model
number
builder
STEP
Level Switches
Step 1b: Model Selection
Pressure Rating & Specific Gravity 1b
108 A-E1A-F-A1-N4-CRTT
Using selected Model, refer to the charts on pages 8-13 to match required pressure rating
and specific gravity, based on design temperature. Once model number has been selected,
go to page 14 for Step 2.
8/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 1b: Model Selection
Pressure Rating & Specific Gravity 1b
108 A-E1A-F-A1-N4-CRTT
108/208 Float operated, horizontal mounted switches with sealed, tamper-proof or flanged,
serviceable chambers. See page 27 for pressure ratings at higher temperatures.
Maximum Working Pressure
Chamber Pressure at Listed Temperature in psi (bar)
Model
Material 100F (38C) 200F (93C) 300F (149C) 350F (177C) 400F (204C) 450F (232C)
A106B 740 (51.0) 675 (46.5) 655 (45.1) 645 (44.4) 635 (43.7) 622 (42.8)
108
316SS 720 (49.6) 620 (42.7) 560 (38.6) 537 (37.0) 515 (35.5) 497 (34.2)
A106B 1794 (123.6) 1794 (123.6) 1794 (123.6) 1794 (123.6) 1794 (128.0) 1794 (128.0)
208
316SS 2248 (155.0) 1937 (133.5) 1746 (120.3) 1644 (133.4) 1602 (110.4) 1548 (106.7)
Minimum Specific Gravity For all model series 108/208, single switch only is equal to .65.
Consult the factory for units used with specific gravity lower than .65.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 9/48
model
number
builder
STEP
Level Switches
Step 1b: Model Selection
Pressure Rating & Specific Gravity 1b
108 A-E1A-F-A1-N4-CRTT
10/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 1b: Model Selection
Pressure Rating & Specific Gravity 1b
108 A-E1A-F-A1-N4-CRTT
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 11/48
model
number
builder
STEP
Level Switches
Step 1b: Model Selection
Pressure Rating & Specific Gravity 1b
108 A-E1A-F-A1-N4-CRTT
700 Series Single-stage, displacer-operated and suitable for top-insertion tank mounting.
Maximum Working Pressure
Minimum Pressure Rating - psi (bar)
Connection Displacer Connection
Model Specific Function
Style Material Material 100F (38C) 450F (232C)4
Gravity1 2 3
701 0.48 Porcelain All 1000 (69) 750 (52)
NPT
702 0.43 SS All 1000 (69) 750 (52)
Narrow A105 285 (20) 185 (13)
703 0.48 Flange Porcelain
Differential 316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
704 0.43 Flange SS
316SS 275 (19) 182 (13)
705 0.32 Porcelain All 1000 (69) 750 (52)
NPT
706 0.29 SS All 1000 (69) 750 (52)
Wide A105 285 (20) 185 (13)
707 0.32 Flange Porcelain
Differential 316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
708 0.29 Flange SS
316SS 275 (19) 182 (13)
Notes: 1. An operating specific gravity is required for all 705 through 708 models at time of order.
2. Minimum SG based on standard sized displacers and units without anti-vibration, pneumatic or
extra high temperature switches.
3. For SS displacers, lower SGs may be achieved using non-standard sized sensors.
4. Standard displacer units are not available over 450oF (232oC). For higher temperatures up to 650F (343C), a
special high temperature spring is available.
730 Series Dual-stage, displacer-operated and suitable for top-insertion tank mounting.
Maximum Working Pressure
Minimum Pressure Rating - psi (bar)
Connection Displacer Connection
Model Specific Function
Style Material Material 100F (38C) 450F (232C)4
Gravity123
730 0.64 Porcelain All 1000 (69) 750 (52)
NPT
731 0.57 SS All 1000 (69) 750 (52)
Narrow A105 285 (20) 185 (13)
732 0.64 Flange Porcelain
Differential 316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
733 0.57 Flange SS
316SS 275 (19) 182 (13)
734 0.55 Porcelain All 1000 (69) 750 (52)
NPT
735 0.49 SS All 1000 (69) 750 (52)
Wide A105 285 (20) 185 (13)
736 .055 Flange Porcelain
Differential 316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
737 0.49 Flange SS
316SS 275 (19) 182 (13)
Notes: 1. An operating specific gravity is required for all 730 models at time of order.
2. Minimum SG based on standard sized displacers and units without anti-vibration, pneumatic or
extra high temperature switches.
3. For SS displacers, lower SGs may be achieved using non-standard sized sensors.
4. Standard displacer units are not available over 450oF (232oC). For higher temperatures up to 650F (343C), a
special high temperature spring is available.
12/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 1b: Model Selection
Pressure Rating & Specific Gravity 1b
108 A-E1A-F-A1-N4-CRTT
750 Series Three-stage, displacer-operated and suitable for top-insertion tank mounting.
Maximum Working Pressure
Minimum Pressure Rating - psi (bar)
Connection Displacer Connection
Model Specific Function
Style Material Material 100F (38C) 450F (232C)4
Gravity1 2 3
750 0.80 Porcelain All 1000 (69) 750 (52)
NPT
751 0.71 SS All 1000 (69) 750 (52)
Narrow A105 285 (20) 185 (13)
752 0.80 Flange Porcelain
Differential 316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
753 0.71 Flange SS
316SS 275 (19) 182 (13)
754 0.85 Porcelain All 1000 (69) 750 (52)
NPT
755 0.81 SS All 1000 (69) 750 (52)
Wide A105 285 (20) 185 (13)
756 0.85 Flange Porcelain
Differential 316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
757 0.81 Flange SS
316SS 275 (19) 182 (13)
Notes: 1. An operating specific gravity is required for all 750 models at time of order.
2. Minimum SG based on standard sized displacers and units without anti-vibration, pneumatic or
extra high temperature switches.
3. For SS displacers, lower SGs may be achieved using non-standard sized sensors.
4. Standard displacer units are not available over 450oF (232oC). For higher temperatures up to 650F (343C), a
special high temperature spring is available.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 13/48
model
number
builder
STEP
Level Switches
Step 2:
Chamber/Process Connection Material 2
108 A-E1A-F-A1-N4-CRTT
Select chamber process connection material from the following chart. Maximum working pressure
shown in the charts in Step 1b is based on the material selected here. Alternate materials can be
provided, please consult the factory.
Note: Chambered models supplied with A105 and A234-WPB fittings for Carbon steel and A182-316/316L and A403-
316/316L fittings for Stainless Steel configurations.
1100oF (593oC)
1150oF (621oC)
750oF (399oC)
500oF (260oC)
550oF (288oC)
650oF (343oC)
850oF (454oC)
900oF (482oC)
450oF (232oC)
950oF (510oC)
800oF (427oC)
700oF (371oC)
0-400oF (204oC)
Chamber Material
Designator 600oF(316oC)
(Select one)
14/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 3:
Process Connection 3
108 A-E1A-F-A1-N4-CRTT
Select a process connection, size, style and rating from the charts below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 15/48
model
number
builder
STEP
Level Switches
Step 3:
Process Connection 3
108 A-E1A-F-A1-N4-CRTT
740 Series, 741-743, 802, 804 See page 40-43 for dimensions.
Standard Flange
Model Connection
Style NPT Socket
Size 150# RF 300# RF 600# RF 1500# RTJ
Thread Weld
VH A1A A1B A1C A1D A1E A1T
VV - - B1C B1D B1E B1T
1
VVD C1A C1B C1C C1D C1E C1T
VVT - - D1C D1D D1E D1T
VH A5A A5B A5C A5D A5E A5T
740
741-743 VV - - B5C B5D B5E B5T
1-1/2
802 VVD C5A C5B C5C C5D C5E C5T
804
VVT - - D5C D5D D5E D5T
VH A2A* A2B* A2C A2D A2E A2T
VV - - B2C B2D B2E B2T
2
VVD C2A* C2B* C2C C2D C2E C2T
VVT - - D2C D2D D2E D2T
*Not available on Models 740, 741, 742, and 743.
Note: Flanged process connections may reduce the maximum working pressure of the unit.
VH VV VVD VVT
(Vertical/Horizontal) (Vertical/Vertical) (Vertical/Vertical/Drain) (Vertical/Vertical/Tee Drain)
16/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 3:
Process Connection 3
108 A-E1A-F-A1-N4-CRTT
700, 730 and 750 Series See page 44-46 for dimensions.
Connection Connection
Model Style
Size Designator
701
702
705
2-1/2 NPT F7A
706
730
731
734
735
750
751 3 NPT F3A
754
755
703 150# RF Flange F3C
704 3
707 300# RF Flange F3D
708
732
150# RF Flange F4C
733
4
736
300# RF Flange F4D
737
752
753 150# RF Flange F6C
756 6
757 300# RF Flange F6D
Note: Flanged process connections may reduce the maximum working pressure of the unit.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 17/48
model
number
builder
STEP
Level Switches
Step 4:
Trim Material 4
108 A-E1A-F-A1-N4-CRTT
Select the internal trim material from the chart below.
Float/Displacer Attraction Available with Trim
Model
Material Sleeve Material Chamber Material Designator
100 Series
316/316L SS 400 SS A106 Carbon Steel (A) only B
200 Series
300 Series
A106 Carbon Steel (A) or
400 Series 316/316L SS 316/316L SS C
316/316L SS (C)
741-743
802 A106 Carbon Steel (A) or
Monel 400 Monel 400 M
740-804 316/316L SS (C)
702
704
706 316/316L SS 400 SS A106 Carbon Steel (A) only B
708
731
733
735
737
751 A106 Carbon Steel (A) or
753 316/316L SS 316/316L SS C
316/316L SS (C)
755
757
701
703
705 Porcelain 400 SS A106 Carbon Steel (A) only P
707
730
732
734
736
750 A106 Carbon Steel (A) or
752 Porcelain 316/316L SS R
316/316L SS (C)
754
756
Note: Consult the factory for pressure ratings on Monel trim. Standard displacer spring material is Inconel 600.
18/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 5:
Switching Mechanism 5
108 A-E1A-F-A1-N4-CRTT
SOR switching mechanisms are designed for use in harsh industrial atmospheres. SOR offers a
variety of electrical and pneumatic switching mechanism types to fit a wide range of applications.
The basic types of switch mechanisms available are listed below. See page 20 for specifications.
All SOR switching mechanisms are constructed from stainless steel and other durable manufactured
materials. Each mechanism is individually calibrated and inspected to insure accuracy and
repeatability. See below for the benefits and application of each switch type. All mechanisms are
interchangeable with most competitor units.
Types A, B, C, E; Standard Dry-Contact Switches
Standard dry-contact switches have open mechanisms and exposed switching elements.
These switching mechanisms are easy to maintain. Visual confirmation of operation is obvious.
Dry-contact switch mechanisms are recommended for most level switch applications and are
available in SPDT and DPDT switch arrangements.
High-load carrying capacity
High-quality phenolic insulator
Vibration resistance
Versatility of application
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 19/48
model
number
builder
STEP
Level Switches
Step 5:
Switching Mechanism 5
108 A-E1A-F-A1-N4-CRTT
110-130VDC
210-250VDC
110-130VDC
210-250VDC
110-130VAC
210-250VAC
110-130VAC
210-250VAC
Minimum Maximum
20-30VDC
20-30VDC
Switch Designator
Temperature1 Temperature2
Hi-Temperature Dry
B 5 5 1.5 .5 - 5 5 1 .25 - -15F (-26C) 400F (204C)
Contact
F Hermetically Sealed 11 11 5 .5 .25 11 11 .25 .25 .13 -65F (-54C) 250F (121C)
Gold Contact
G7 1 - 1 - - 1 - .5 - - -65F (-54C) 250F (121C)
Hermetically Sealed
High-Temperature
H 5 5 1.5 .3 - 5 5 1 .25 - -65F (-54C) 350F (177C)
Hermetically Sealed
Mini-Hermetically DPDT 5 5 5 .5 - 5 5 2.5 .25 -
L5 -15F (-26C) 250F (121C)
Sealed SPDT 11 11 5 .5 .25 11 11 2.5 .25 .13
Anti-Vibration Gold
R 1 - 1 - - 1 - .5 - - -15F (-26C) 250F (121C)
Contact
Gold Contact
S7 1 - 1 - - 1 - .5 - - -15F (-26C) 250F (121C)
Mini-Hermet
Anti-Vibration DPDT 5 5 5 .5 - 5 5 2.5 .25 - -15F (-26C) 250F (121C)
T5
Mini-Hermet SPDT 11 11 5 .5 .25 11 11 2.5 .5 .13 -15F (-26C) 250F (121C)
High-Temperature
V7 5 5 1.5 .5 - 5 5 1 .25 - -15F (-26C) 400F (204C)
Mini-Hermet
Extra-High Temperature -40F (-40C)
Y6 1 1 1 .4 - 1 1 .4 - - 800F (427C)
(Ceramic) Note 3
Non-bleed 3-way aluminum valve body.
J4 Pneumatic 316SS
Buna-N O-Rings 5F (-15C) 200F (93C)
Fittings
150 psi maximum supply, 24CFM @ 100 psi
Notes
1. Minimum ambient temperature at which the switch mechanism will operate normally. This may vary according to actual
climatic conditions. Actual minimum process temperature may be much lower. Consult the factory for details.
2. Maximum process temperature at which the switch mechanism will operate normally. This can be increased according
to the type of process. Refer to pages 25-26 for more details.
3. -40F Temperature rating with no icing.
4. Pneumatic switches must be used with clean, dry air or gas.
5. These switch designators have higher current rating for SPDT than DPDT.
6. Manufacturer specifications state maximum operating humidity must be <85% and minimum power rating is 100mW.
7. For high humidity environments and low current (<100mA), use hermetically sealed gold contact switches (S & G
switches). For high temperatures, high humidity, and low current, a V switch is available with gold contacts upon request.
20/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 5:
Switching Mechanism 5
108 A-E1A-F-A1-N4-CRTT
Select the switch mechanism from the chart below. See page 20 for contact and temperature ratings.
SPDT DPDT
3-Way Available Agency
Switch Type Single Pole Double Pole
Valve Listings
Double Throw Double Throw
Single Dual Triple Single Dual Triple Single
INMETRO (flameproof)
Rostechnadzor (RTN)
ATEX/ IECEx (IS)
Switching Stages
INMETRO (IS)
CSA
UL
Switching Description Designator
Standard Dry Contact A1 A2 A3 A4 A5 A8 - l l l l l
High-Temperature Dry Contact B1 B2 B3 B4 B5 B8 - l l l l l
Gold Contact C1 C2 C3 C4 C5 C8 - l l l l l l l
1 1 1
Anti-Vibration Dry Contact D1 - - D4 - - - l l l l l
High-Amperage DC Service E1 E2 E3 E4 E5 E8 - l l l l l
Hermetically Sealed F1 F2 F3 F4 F5 F8 - l l l l l
730 l l l l l l l l l
750 l l l l
(enclosures N1, N8 or B5 only)
Notes
1. These switches use two magnets and must be considered dual mechanisms when figuring minimum specific gravity.
2. Pneumatic switching mechanisms must be specified with P1 housing.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 21/48
model
number
builder
STEP
Level Switches
Step 6:
Housing 6
108 A-E1A-F-A1-N4-CRTT
SOR housings are designed to protect the switching mechanisms from harsh environmental
conditions, as well as protecting the surrounding atmosphere from potential ignition sources.
The basic types of housings are listed below.
Explosion-Proof Housings
Available in aluminum or cast iron
Ratings as shown in chart below
Rostechnadzor
Electical/
INMETRO
Designator
740, 800
Connections
Canada
IECEx
750s
730s
700s
ATEX
USA
B1 Aluminum Groups B C D E F G n n
B2 Cast Iron Groups B C D E F G n n
Aluminum
B52 Groups B C D E F G n n
Extended
Aluminum
N1 1 NPT NEMA 4, 4X n
Extended
N4 Aluminum NEMA 4, 4X n
N7 Aluminum Groups C D F G n n
Aluminum
N8 Groups C D E F G n n
Extended
Aluminum
P11 (3) 1/4 NPT NEMA 4, 4X
Pneumatic
S3 Aluminum 1 NPT w/ Ex d IIC T6 Gb n
S82 Cast Iron M20 x Ex d IIC T6 n
T62 Cast Iron 1.5 adapter3 Ex d IIC T6 Gb n n
Available
Standard
Notes:
1. P1 housing must be used with pneumatic switch mechanisms.
2. B5 housing is rated for Groups B C D E F G in Canada, and Groups C D F G in the USA.
3. M20 adapters are brass. Consult factory for alternate materials.
22/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
model
number
builder
STEP
Level Switches
Step 7:
Accessories/Certificates 7
108 A-E1A-F-A1-N4-CRTT
SOR accessories are provided for customizing the level switches in this
catalog according to the requirements of the application. Place accessory designator(s) from the table below
at the end of the model number. Check the compatibility chart below for correct use of each accessory.
Model Series
Designator
Accessory
Description 741-
108/ 740
100 200 300 400 743 700 730 750
208 804
802
AF1 Air Filter & Gauge l l l l l l l l
CL ATEX/IECEx Approval for S3 Hsg l l l l l l l l l
CN 7
Conduit Reducer M20 x 1.5 l l l l l l l l l l
CP7 Conduit Reducer 1/2 NPT l l l l l l l l l l
CR7 Conduit Reducer 3/4 NPT l l l l l l l l l l
CS2 CSA Certification l l l l l l l l l l
CV Canadian Registration Number (CRN) l l l l l l l l l l
CY Certificate of Conformance l l l l l l
(Power Piping, ASME 31.1)
CZ3 Certificate of Conformance l l l l l l
(Process Piping, ASME 31.3)
DN Special Drain Connection l l l l
EC8 Extra Chamber Connection C/F C/F C/F C/F C/F
ET5 Temperature Extension l l l l l l l l l l
FE5 Finned Extention l l l l
GG Sealed Conduit l l l l l l l l l
ID 9
Interface Detection l l l l l
KK Housing Breather Drain l l l l l l l l l l
MC4 Manual Check l l
MR Mill Test Report l l l l l l l l l l
MT10 Mag Particle Examination l l l l l l
NC NACE Construction l l l l l l l l l l
NM INMETRO Approved for S3 Hsg l l l l l l l l l
PP Fiber Tag l l l l l l l l l l
PT Dye Penetration Examination l l l l l l
PY Powder coat epoxy coating. No coating on
stainless steel parts or plated screws. (500 l l l l l l l l l l
hrs. salt spray)
RR SS Tag wired to housing l l l l l l l l l l
RT Radiograph Examination l l l l l l
SC11 Special Calibration C/F C/F C/F C/F C/F C/F C/F C/F C/F C/F
SD12 Special Dimensions C/F C/F C/F C/F C/F
SL13 Special Cable Length l l l
TC4 Tru-Check l l
TF Tandem Floats C/F C/F l
TT Oversized Nameplate for customer tagging l l l l l l l l l l
UT Ultrasonic Examination l l l l l l
VV Fungicidal Varnish l l l l l l l l l l
WC Water Column Unit C/F
WV2 UL Listed l l l l l l l l l
YY Epoxy Coating (enclosure only) l l l l l l l l l l
Level Switches
Step 7:
Accessories/Certificates 7
108 A-E1A-F-A1-N4-CRTT
Test Certificates
Certificates
QA Test Report
Dielectric Test
Pressure Test
Compliance /
Conformance
Model Certificate
Hydrostatic
Resistance
Calibration
Inspection
Insulation
Series Designator
Report
C1
C2
C3
C4
C5
C6
100 C7
200 B2
B3
300
B5
400 B6
108/208 B7
A2
A3
A4
A7
A8
A9
C1
700 C3
C4
730
C5
750
C6
*740, 804
C7
741-743
B5
802 B6
B7
*These products also have Certificate C2 - Hydrostatic Pressure Test.
24/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches High Temperature Selection
03
MODEL # SALES ORDER #
The straight temperature extension provides physical distance 180.9 Drawing * MINIMUM
146.1
5.75
O
between the process and the switching mechanism. It is 7.12
0390676 REQUIRED TO REM
101.6
constructed of a straight piece of pipe welded between the 4.00
ISO-9001
W
To Specify PRODUCT CERTIFICA
ALL DIMENSIONS
TEMPERATURE
Add Accessory Designator ET to the end of the SOR level EXTENSION
UNLESS OTHERWI
LINEAR =
switch model number per the selection chart on page 26.
THIS DRAWING IS T
NO USE WHATSOEVER
The ET accessory automatically matches the material and HEREON, NOR REPROD
MADE WITHOUT THE EX
FE Accessories
The finned temperature extension is designed to protect the electrical portion of a level switch
from heat damage due to condensing processes. When used in combination with high-temperature
switch mechanisms, this option allows operation in process temperatures up to 1200oF (649oC).
How It Works
The finned temperature extension condenses process steam and reduces
its heat before it can reach the switching mechanism. The design reduces
steam to its saturation temperature in the enclosing tube, protecting the
switching mechanism from deterioration due to high temperatures.
The process pressure dictates the saturation temperature, see page 32.
To Specify
Add Accessory Designator FE to the end of the SOR level switch model
number per the selection chart on page 26.
The finned temperature extension automatically matches the material and rating
of the specified level switch chamber. These options can be supplied on
SOR level switches 100, 200,108/208, 300 and 400 Series.
Note: For proper cooling, temperature extensions must not be insulated or placed inside an enclosed
structure. High ambient temperatures (over 100oF/38oC), intense direct sunlight, or heat loading
from adjacent piping or vessels will affect cooling performance.
Consult the factory if any of these conditions exist.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 25/48
Level Switches High Temperature Selection
Fundamental differences in condensing (steam) and non-condensing (dry) heat require different
methods of protection.
Steam Heat processes carry its heat with the vapor. These processes effectively heat every portion
of their enclosure. To reduce the heat effects of condensing processes, we must either condense or
physically block the vapor. SOR uses a condensing system to avoid the sealing problems associated
with blocking the steam.
Dry Heat processes transfer heat through direct conduction. Heat is only passed to the areas where
they touch the enclosure. Therefore, radiant heat is the only concern with these processes. This may
be resolved by adding distance between the process and the protected portion of the control.
Using the charts below, find your desired maximum temperature and select a corresponding
chamber material. In the process type chart, select a switch mechanism based on whether you are
using Steam Heat or Dry Heat. The symbol will indicate if a temperature reduction device is required.
1100oF (593oC)
1150oF (621oC)
750oF (399oC)
500oF (260oC)
550oF (288oC)
650oF (343oC)
850oF (454oC)
900oF (482oC)
450oF (232oC)
950oF (510oC)
800oF (427oC)
700oF (371oC)
0-400oF (204oC)
600oF(316oC)
Chamber Material
Designator
(Select one)
Heat Type
Steam Heat Applications - Switch Mechanism (Select one)
Hi-Temp Dry Contact
B/V n l l v v
or Mini-Hermet
Hi-Temperature
Y n n n n n n n n n v v v v v v v v
Ceramic/SS
Dry Heat Applications - Switch Mechanism (Select one)
Hi-Temp Mini-Hermet
B/V n l l l l
or Dry Contact
Hi-Temperature
Y n n n n n n n n n l l l l
Ceramic/SS
For proper cooling, temperature extensions and finned extensions must not be insulated or placed inside an enclosed
structure. High ambient temperatures (over 100F/38C), intense direct sunlight or heat loading from adjacent piping or
vessels will affect cooling performance. Consult the factory if any of these conditions exist.
26/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches High Temperature Selection
Float Switch Pressure Ratings (in psi) above 450F (232C). Higher temperatures
available with other materials. Consult factory.
Pressure at Listed Temperature in psi
Model Material 500F 550F 600F 650F 700F 750F
(260C) (288C) (316C) (343C) (371C) (399C)
101 CS & SS 170 155 140 125 110 95
102 CS & SS 447 435 423 411 400 389
CS 600 575 550 535 535 505
103
SS 480 465 450 445 430 425
104 CS & SS 894 870 846 823 800 778
CS 600 575 550 535 535 505
108
SS 480 465 450 445 430 425
109 CS & SS 170 155 140 125 110 95
121 CS & SS 170 155 140 125 110 95
122 CS & SS 313 304 296 288 280 272
201 CS & SS 201 196 190 185 180 175
202 CS & SS 268 261 254 247 240 233
203 CS & SS 447 435 423 411 400 389
204 CS & SS 1118 1087 1057 1029 1000 972
205 CS & SS 671 652 634 617 600 584
206 CS & SS 894 870 846 823 800 778
207 CS & SS 894 870 846 823 800 778
CS 1794 1794 1794 1794 1722 1554
208
SS 1495 1453 1411 1387 1351 1339
209 CS & SS 403 391 381 370 360 350
221 CS & SS 313 304 296 288 280 272
CS = Carbon Steel
SS = Stainless Steel
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 27/48
Level Switches MC and TC options
Manual Check (MC) and Tru-Check (TC) options permit manual actuation of vertical displacer level
switches, addressing EPA and OSHA safety requirements. The standard 30-foot stainless steel
chain allows manual actuation from the tank base, eliminating potentially hazardous trips to the top
of the tank. Specify either an MC or TC option by placing the designator in the accessory section of
the model number.
Designator Application
TC Tanks or vessels pressurized to 100 psi
MC Atmospheric vented tanks or vessels
These options are available on SOR level switch Series 701 through 704 and 730 through 733. MC and
TC option available on carbon steel units only. Series 730 through 733 are more sensitive to both high
and low SG values. Please consult factory before ordering the MC or TC options for these models.
How It Works
Pulling the handle transfers downward motion to the actuator lever by means of the beaded
stainless steel chain. The resultant motion lifts the entire level sensing assembly which moves
the attraction sleeve and actuates the switching element to simulate a high-level condition.
Switching action for alarm, shutdown or control is verified.
Dimensions
SALES ORDER # LINE ITEM # PURCHASE ORDER #
101.6 393.7
Product Specifications
4.00 15.50
Pressure Range
TC (Tru-Check) *0 to 100 psi
MC (Manual Check) 0 psi (vented to atmosphere)
W
*Maximum pressure for entire level sensing assembly
is 100 psi with Tru-Check installed.
*456.4
17.97
K MITCHELL
PRODUCT CERTIFICATION DRAWING CHECKED BY
ALL DIMENSIONS ARE 1/16 IN
M SMITH
UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
LINEAR = J FIFE
IN
DATE
28/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches Examination and testing requirements
Specify either a CY or CZ option in the accessory section of the model number for a certificate of conformance.
Designator Certificate of Conformance to
CY ASME B31.1 Power Piping
CZ ASME B31.3 Process Piping
If certification to B31.3 is required, SOR Inc. must know the fluid category per the chart below. Read the ASME B31.3
Fluid Category Section at the bottom of this page to determine the applicable category.
Visual Radiographic Magnetic Dye
Units Covered Hydrotest
Examination1 (X-Ray) RT Particle MT Penetrant PT
Standard Inspection
1.5 x pressure for
All Chambers 100% 0% 0% 0%
3 minutes
CY Option (ASME B31.1)
Below 750F
100% - - -
Below 1025 psi
Below 350F
100% - - -
All pressures 1.5 x pressure for
350F - 750F 10 minutes
100% All butt welds >2 - -
Above 1025 psi
Above 750F Butt welds >2 all Butt welds >2 all
100% All butt welds >2
All pressures other welds other welds
CZ Option (ASME B31.3)
Normal Fluid 5% 5%2 - -
Engineering/QA
Category D - - -
Choice 1.5 x pressure for
Category M 100% 20% of all welds 3
- - 10 minutes
100% of girth/
High Pressure 100% - -
branch welds
Notes
1. In process visual inspection: inspecting pipe bevel prior to welding, check fit-up, check after-tack weld, and check
during weld passes. After completion visual inspection: welding and grinding is checked.
2. In process examination may be substituted on a weld-for-weld basis.
3. In process examination supplemented by appropriate NDE (MT or PT) may be substituted on a weld-for-weld basis.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 29/48
Level Switches ASTM Material Designations
SOR uses all ASTM grade materials in the construction of mechanical level switches. The following
chart lists the specific ASTM (or UNS) materials that are normally used for each component in our
switches. Consult the factory if you do not see the specific material required for your application.
ASTM Spec-Grade ASME B16.9 ASME 16.11 ASME B16.5
Temperature
Material Seamless Wrought Forged Fittings
Pipe Flanges Range
Pipe Butt Weld Fitting SW/Threaded
Carbon Steel A106B A234-WPB A105 A105 -20F to 800F
304/304LSS 2
A312-TP304 A403-WP304 A182-F304 A182-F304 -425F to 1000F
316/316LSS A312-TP316 A403-WP316 A182-F316 A182-F316 -325F to 1000F
Low Temperature
A333 Gr. 6 A420-WPL6 A350-LF2 A350-LF2 -50F to 700F
Carbon Steel2
1-1/4% Chrome
A335-P11 A234-WP11 A182-F11 A182-F11 -20F to 1100F
1/2% Moly2
Hastelloy-C2762
B6221 B366/B564 B366/B564 B366/B564 -325F to 800F
N10276
Alloy-202
B4641 B366/B962 B366/B462 B366/B462 -325F to 800F
N08020
Monel 4002 B564
B-1651 B366 B564 -325F to 900F
N04400 Gr N0 4400
Duplex SS2 A-790 A-815 A182-F51 A182-F51 -60F to 600F
2-1/4% Chrome
A335-P22 A335-WP22 A182-F22 A182-F22 -20F to 1100F
1% Moly2
9% Chrome
A335-P91 A234-WP91 A182-F91 A182-F91 -20F to 1200F
1% Moly Vanadium2
Notes
1. UNS numbers are given for special alloys.
2. These materials are available by special order only.
30/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches weights
The approximate shipping weights shown below are for standard models. Weights will vary based on
pipe size, length and flange size. Consult the factory for the weight of a specific unit.
Floats Displacers
Model pounds kilograms Page Model pounds kilograms Page
101* 55 25 33 701 18 8.5 44
102* 80 37 33 702 18 8.5 44
103* 130 60 33 703 30 13.5 44
108 130 59 37 704 30 13.5 44
109* 125 53 33 705 20 9 44
121* 40 18 33 706 30 9 44
122* 50 23 33 707 32 14.5 44
123* 80 36 33 708 32 14.5 44
124* 90 42 33 730 20 9 45
201* 45 20.5 35 731 20 9 45
202* 26 12 35 732 32 14.5 45
203* 26 12 35 733 32 14.5 45
204* 26 12 35 734 22 10 45
205* 45 20.5 35 735 22 10 45
206* 45 20.5 35 736 34 15.5 45
207* 45 20.5 35 737 34 15.5 45
208 89 22 37 740* 28 12.5 42
209* 62 29 35 741* 48 22 40
221* 22 10 35 742* 60 27 40
301 12 5.5 38 743* 68 31 40
303 12 5.5 38 750 24 11 46
304 12 5.5 38 751 24 11 46
401 15 7 39 752 36 16 46
402 12 5.5 39 753 36 16 46
403 28 12.5 39 754 26 12 46
404 15 7 39 755 26 12 46
405 12 19 39 756 38 17 46
406 70 32 39 757 38 17 46
802 185 82 40
804 50 22.5 42
* Add weights from the table below to the base model weight for VV, VVT, or VH configurations with flanges.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 31/48
Level Switches Specific Gravity of Water
The specific gravity of water changes depending on its temperature and pressure. The chart below
lists properties of saturated steam. Saturated steam is the state where water is in transition between
liquid and vapor. The chart provides the process temperature with the associated pressure and
specific gravity of the condensate water. If a water application has a high temperature and low
pressure, condensate will only be present at the temperature that corresponds to the maximum
pressure. Select the proper row based on the temperature and pressure, and read the specific gravity.
Figures are based on saturated steam.
32/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches 100 series calibration dimensions
Chamber Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear
= mm/in.) They are subject to change without notice. Contact SOR for certified drawings of particular
0390021
DRAWING NUMBER
03
MODEL # SALES ORDER #
146.1
180.9 * MINIMUM
PURCHASE ORDER # OVERHEAD CLEARANCE
146.1 5.75
180.9 * MINIMUM OVERHEAD CLEARANCE 7.12
5.75 REQUIRED TO REMOVE HOUSING COVER.
7.12 180.9
101.6 REQUIRED TO REMOVE HOUSING COVER.
101.6 7.12 146.1
* MINIMUM O
4.00 4.00 101.6
5.75
REQUIRED TO REMO
4.00
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 33/48
Level Switches 100 series chamber dimensions
1 Connection
D1, 2 E1, 2 F4 G H4 I2 L2
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
101 16-5/8 (422)
10-1/2 (267) 3-3/4 (95) 6-1/2 (165) 14 (356) 14 (356) 3-3/4 (95)
102 17-5/16 (440)
103 18 (457)
10-1/4 (260) 4-13/16 (122) 7-7/16 (189) 14 (356) 14 (356) 4-9/16 (116)
104 19-3/4 (502)
109 12-5/8 (321) 5-13/16 (148) 8-7/16 (214) 16 (406) 16 (406) 7-1/2 (191) 17-13/16 (452)
121 16-3/8 (416)
9 (229) 3-1/4 (83) 6 (152) 14 (356) 14 (356) 3-3/4 (95)
122 16-15/16 (430)
123 17-5/16 (440)
10-1/2 (267) 3-3/4 (95) 6-1/2 (165) 14 (356) 14 (356) 3-3/4 (95)
124 18-3/4 (476)
1-1/2 Connection
D1, 2 E1, 2 F4 G H4 I2 L2
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
101 16-5/8 (422)
10-1/2 (267) 4 (102) 6-1/2 (165) 14 (356) 14 (356) 3-3/4 (95)
102 17-5/16 (440)
103 18 (457)
10-1/4 (260) 5-1/16 (129) 7-7/16 (189) 14 (356) 14 (356) 4-9/16 (116)
104 19-3/4 (502)
109 13-1/16 (332) 6-1/16 (154) 8-7/16 (214) 16 (406) 16 (406) 7-1/2 (191) 17-13/16 (452)
121 16-3/8 (416)
9 (229) 3-1/2 (89) 6 (152) 14 (356) 14 (356) 3-3/4 (95)
122 16-15/16 (430)
123 17-5/16 (440)
10-1/2 (267) 4 (102) 6-1/2 (165) 14 (356) 14 (356) 3-3/4 (95)
124 18-3/4 (476)
2 Connection
D1, 2 E1, 2 F4 G H4 I2, 3 L2, 3
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
101 17-5/8 (448)
10-1/2 (267) 4-5/16 (110) 6-1/2 (165) 14 (356) 14 (356) 4-3/4 (121)
102 18-5/16 (467)
103 19 (483)
10-1/4 (260) 5-3/8 (137) 7-7/16 (189) 14 (356) 14 (356) 4-9/16 (116)
104 20-3/4 (527)
109 13-3/8 (340) 6-3/8 (162) 8-7/16 (214) 16 (406) 16 (406) 8-1/2 (216) 18-13/16 (478)
121 16-3/8 (416)5
- - 6 (152) 14 (356) 14 (356) 3-3/4 (95)5
122 16-15/16 (430)5
123 18-5/16 (465)
10-1/2 (267) 4-5/16 (110) 6-1/2 (165) 14 (356) 14 (356) 4-3/4 (121)
124 19-3/4 (502)
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
34/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches 200 series calibration dimensions
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.)
They are subject to change without notice. Contact SOR for certified drawings of particular models DRAWING NUMBER
or if special dimensions are required. W designates electrical connection, see page 22 for more
DRAWING NUMBER
0390660
MODEL #
PURCHASE ORDER #
DRAWING NUMBER
0390661
SALES ORDER #
MODEL #
PURCHASE ORDER #
housing information. MODEL # SALES ORDER #
LINE ITEM #
SALES ORDER #
PURCHASE ORDER # LINE ITEM # 180.9 146.1
* MINIMUM O
146.1 7.12 5.75
* MINIMUM OVERHEAD CLEARANCE REQUIRED TO REM
5.75 101.6
REQUIRED TO REMOVE HOUSING COVER. 180.9 146.1
180.9 * MINIMUM OVERHEAD CLEARANCE
4.00
7.12 5.75
7.12
REQUIRED TO REMOVE HOUSING COVER.
101.6 101.6
4.00 4.00 THIS DRAWING WAS CREATED USING
*228.6
THE VERTICAL_MOUNT_ASSY AND TEXT 9.00
FILE 0390660.txt
W LOCATED ON THE
THIS DRAWING WAS CREATED US
K:\$Engineering Services\Concept text filesL THE VERTICAL_MOUNT_ASSY AND
*228.6 *228.6 FILE 0390661.txt LOCATED ON TH
W 9.00 W 9.00 THEN THE DRAWING WAS CHANGED TO
DRAFT ENTITIES. W K:\$Engineering Services\Concept t
L L THEN THE DRAWING WAS CHANG
DRAFT ENTITIES. 14685 W
W W ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630 14685 W 105TH ST LENEXA, KS 66215 USA
ISO-9001 SORINC.COM 913-888-2630
ISO-9001 355.6
SORINC.COM PRODUCT CERTIFIC
DRAWN BY
ALL DIMENSIONS
M SMITH 14.00 DRAWN BY
UNLESS OTHERW
PRODUCT CERTIFICATION DRAWING M SMITH
D ALL DIMENSIONS ARE 1/16 IN
CHECKED BY
PRODUCT CERTIFICATION DRAWING LINEAR
J REHM CHECKED BY
H UNLESS OTHERWISE SPECIFIED
G ENGINEER APPROVAL
ALL DIMENSIONS ARE 1/16 IN
J REHM
MM UNLESS OTHERWISE SPECIFIED
LINEAR = J FIFE ENGINEER APPROVAL
IN MM
DATE LINEAR = J FIFE THIS DRAWING IS
IN NO USE WHATSOEVE
3/15/11 DATE
I 3/15/11
HEREON, NOR REPRO
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. MADE WITHOUT THE
NO USE WHATSOEVER OF THE INFORMATION CONTAINED THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE TITLE
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE DIM DWG 200 SERIES
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. VVD
E 1" SW
TITLE
DRAIN CONN E
DIM DWG 200 SERIES SEALED CHAMBER TITLE
EO NUMBER: 5090
(VVT ONLY)
VH 1"NPT OR DIM
SW DWG 200 SERIES SEALED CHAMBER
F
Drawing 0390660 F
EO NUMBER: 5090 DRAWING NUMBER
Drawing
0390660
0390661
2
REV VV, VVT F
DRAWING NUMBER
Drawing 0390662
REV
SCALE: DRAWING SCA
EO NUMBER: 5090 DO NOT SCALE PRINT
SCALE: DRAWING SCALE DWG SIZE 0390661 2
SHEET 1 OF 1 Model Name: MODEL NAME.DRAFT/1/3+
SCALE: DRAWING SCALE
DO NOT SCALE PRINT A DWG SIZE
SHEET 1 OF 1
Model Name: MODEL NAME.DRAFT/2/0+ DO NOT SCALE PRINT A
Model Name: MODEL NAME.DRAFT/1/4+ Reset Form
Reset Form
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 35/48
Level Switches 200 series chamber dimensions
1 Connections
D1, 2 E1, 2 F4 G H4 I1, 2 L2
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
201 10-1/4 (260) 4-13/16 (122) 7-7/16 (189) 14 (356) 14 (356) 4-9/16 (116) 15-3/16 (386)
202
203 10-1/2 (267) 3-3/4 (95) 6-1/2 (165) 14 (356) 14 (356) 3-3/4 (95) 14-3/8 (365)
204
205
206 10-1/4 (260) 4-13/16 (122) 7-7/16 (189) 14 (356) 14 (356) 4-9/16 (116) 15-3/16 (386)
207
209 12-5/8 (321) 5-13/16 (148) 8-7/16 (214) 16 (406) 16 (406) 7-1/2 (191) 18-1/16 (459)
221 9 (229) 3-1/4 (83) 6 (152) 14 (356) 14 (356) 3-3/4 (95) 14-3/8 (365)
1-1/2 Connections
D2 E2 F4 G H4 I2 L2
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
201 10-1/4 (260) 4-13/16 (122) 7-7/16 (189) 14 (356) 14 (356) 4-9/16 (116) 15-3/16 (386)
202
203 10-1/2 (267) 4 (102) 6-1/2 (165) 14 (356) 14 (356) 3-3/4 (95) 14-3/8 (365)
204
205
206 10-1/4 (260) 5-1/16 (129) 7-7/16 (189) 14 (356) 14 (356) 4-9/16 (116) 15-3/16 (386)
207
209 13-1/16 (332) 6-1/16 (154) 8-7/16 (214) 16 (406) 16 (406) 7-1/2 (191) 18-1/16 (459)
221 9 (229) 3-1/2 (89) 6 (152) 14 (356) 14 (356) 3-3/4 (95) 14-3/8 (365)
2 Connections
D2 E2 F4 G H4 I2, 3 L2, 3
Model
inch (mm) inch inch inch inch inch inch
201 10-1/4 (260) 5-3/8 (137) 7-7/16 (189) 14 (356) 14 (356) 5-9/16 (141) 16-3/16 (411)
202
203 10-1/2 (267) 4-5/16 (110) 6-1/2 (165) 14 (356) 14 (356) 4-3/4 (121) 15-3/8 (391)
204
205
206 10-1/4 (260) 5-3/8 (137) 7-7/16 (189) 14 (356) 14 (356) 5-9/16 (141) 16-3/16 (411)
207
209 13-3/8 (340) 6-3/16 (162) 8-7/16 (214) 16 (406) 16 (406) 7-1/2 (191) 19-1/16 (484)
221 - - 6 (152) 14 (356) 14 (356) 3-3/4 (95) 5
14-3/8 (365)
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
36/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches 108/208 chamber dimensions
DRAWING NUMBER
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) DRAWING NUMBER
0390
MODEL #
They are subject to change without notice. Contact
MODEL #
SOR for certified drawings of particular models
0390667 SALES ORDER #
PURCHASE ORDER # SALES ORDER #
or if# special dimensions are required. W designates electrical connection,
PURCHASE ORDER LINE see
ITEM # page 22 for more CONNECTION
MODEL
housing information. MODEL
CONNECTION
A B C
SIZE
SIZE
180.9 180.9 1"
125.4 250.8
7.12 399.0
7.12 1"
4.94 9.88 15.71 101.6 208A
101.6 1-1/2"
4.00 108A 128.5 257.0 402.1 4.00 (CS)
1-1/2"
(CS) 5.06 10.12 15.83
2"
138.2 276.4 411.7
2"
5.44 10.88 16.21
*228.6 *228.6 1"
1"
120.7 241.3 394.2 THIS DRAWING WAS CREATED USIN
Model 108
9.00 4.75 9.50 15.52 9.00 THE HORIZ_MOUNT_ASSY AND TEX
Model 208 208C
1-1/2"
108C
1-1/2"
130.3 260.6 403.9 FILE 0390667.txt LOCATED
(316SST) ON TH
Drawing 0390667 Drawing 0390666
(316SST) 5.13 10.26 15.90 K:\$Engineering Services\Concept te
W 2"
143.0 186.0 416.6 W THEN THE DRAWING WAS 2" CHANGE
5.63 11.25 16.40 DRAFT ENTITIES. 14685 W 10
14685 W 105TH ST LENEXA, KS 66215 USA
C 913-888-2630
A A SORINC.COM
C ISO-9001
ISO-9001
317.5
B B
DRAWN BY
PRODUCT CERTIFICATIO
12.50 M SMITH
PRODUCT CERTIFICATION DRAWING CHECKED BY ALL DIMENSIONS AR
ALL DIMENSIONS ARE 1/16 IN UNLESS OTHERWISE
J REHM
UNLESS OTHERWISE SPECIFIED M
MM
ENGINEER APPROVAL LINEAR =
LINEAR = J FIFE
IN
IN
DATE
3/16/11
164.3 187.3 THIS DRAWING IS THE
200.8 187.3 6.47 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER O
NO USE WHATSOEVER OF THE7.38
INFORMATION CONTAINED HEREON, NOR REPRODUC
7.91 7.38 500.0 IN WHOLE OR PART MAY BE
HEREON, NOR REPRODUCTION MADE WITHOUT THE EXPR
573.1 MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
19.69 TITLE
22.56 TITLE
DIM DWG 208 SERIES HO
DIM DWG 108 SERIES HORIZONITAL
MOUNT FLOAT OPERATED
MOUNT FLOAT OPERATED
146.1 146.1 EO NUMBER: 5090
* OVERHEAD CLEARANCE EO NUMBER: 5090 DRAWING NUMBER
* OVERHEAD CLEARANCE
REV
5.75 0390667 5.75 2 SCALE: DRAWING SCALE
REQUIRED TO REMOVE COVER. SCALE: DRAWING SCALE REQUIRED
DWG SIZE TO REMOVE COVER.
SHEET 1 OF 1 DO NOT SCALE PRINT
DO NOT SCALE PRINT A
Model Name: MODEL NAME.DRAFT/2/0+
Model Name: MODEL NAME.DRAFT/2/0+
Reset Form
Connection A B C
Model
Size inch (mm) inch (mm) inch (mm)
1 4-13/16 (122)* 9-5/8 (244)* 15-1/2 (394)
108 1-1/2 5-1/16 (129)* 10-1/8 (258)* 15-3/4 (401)*
2 5-3/8 (137)* 10-3/4 (274)* 16-1/8 (409)*
1 4-15/16 (125) 9-7/8 (250) 15-5/8 (396)
208 1-1/2 5-1/16 (129)* 10-1/8 (258)* 15-3/4 (401)*
2 5-3/8 (137)* 10-3/4 (274)* 16-1/8 (409)*
*Dimensions valid for socket weld process connections. Consult factory for threaded connection dimensions.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 37/48
Level Switches 300 series unit dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
over inches. (Linear = mm/in.) W designatesMODEL electrical connection, see page 22 for more
MODEL MODEL FL
housing information. 301/304 303
301
180.9 180.9
7.12 7.12 88
303
180.9 180.9
3.
7.12 7.12
101.6 101.6
4.00 4.00
Tandem
101.6 101.6 304
4.00 4.00
0390007
REV
4
SCHEDULE TO PROVIDE FLOAT INSERTION CLEARANCE. SHEET 1 OF 1 LINEAR =
Drawing
DO NOT SCALE PRINT B SCALE: 0.33 DWG SIZE
3+ SHEET 1 OF 1
DO NOT SCALE PRINT B
Model Name: 0390007.ASSEM/3/0+
38/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches 400 series chamber dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.) W designates electrical connection, see page 22 for more
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
Drawing 0390669
Models 401, 402, 404
W CUSTOMER
STANDARD DIF
PROCESS
CONNECTION MODEL "D
405
406
D 1
FLOAT 14685 W 105TH ST LEN
913-888
ISO-9001 SORINC.
457
263.5 THIS DRAWING IS THE EXCLUSIVE PR
18.0
10.38 NO USE WHATSOEVER OF THE INFORM
HEREON, NOR REPRODUCTION IN WHO
MADE WITHOUT THE EXPRESS WRITTEN
TITLE
D @ Minimum
Model Specific Gravity
inch (mm)
401
402
3 (76)
403
404
405
2-3/4 (70)
406
Note: With anti-vibration, extra-high temperature
and pneumatic switch, minimum differential will
increase.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 39/48
Level Switches 741-743 & 802 chamber dimensions
DR
J REHM
H UNLESS OTHERWISE SPECIFIEDG ENGINEER APPROVAL
MM
LINEAR = J FIFE
IN
DATE TH
3/14/11 NO U
HEREO
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. MADE
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE TITLE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. DIM DWG
E 1"TITLE
SW EXTERNAL
(VVT ONLY)
DIM DWG 100 SERIES SERVICEABLE
Drawing 0390019 EXTERNAL CHAMBERFVH STYLE
Drawing 0390021 EO NUMB
F DRAWING NUMBER REV SCALE: D
EO NUMBER: 5090
0390019 3 DO NO
SCALE: DRAWING SCALE DWG SIZE
Model Name: MODEL NAME.DRAFT/3/0+
SHEET 1 OF 1
DO NOT SCALE PRINT A
Model Name: MODEL NAME.DRAFT/3/1+
Reset Form
40/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
DRAWING NUMBER
0390010
MODEL # SALES ORDER #
PURCHASE ORDER # LINE ITEM #
Level Switches
DRAWING NUMBER
741-743
180.9 & 802 chamber dimensions
7.12 146.1
0390010
MODEL # * MINIMUM SALES
OVERHEAD ORDER #
CLEARANCE
5.75
PURCHASE ORDER # 101.6 LINE ITEM #
REQUIRED TO REMOVE HOUSING COVER.
4.00
180.9
7.12 146.1 THIS DRAWIN
* MINIMUM OVERHEAD CLEARANCE
W 101.6
5.75 THE VERTICA
*228.6 REQUIRED TO REMOVE HOUSING COVER.
9.00 4.00 FILE 0390010
K:\$Engineeri
L THEN THE DR
DRAFT ENTIT
W W *228.6
9.00
M SMITH
PRODUCT CERTIFICATION DRAWING
355.6 ALL DIMENSIONS ARE 1/16 IN
CHECKED BY
14685 W 105TH ST LENEXA, KS 66215
J REHM
14.00 UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
913-888-2630
MM ISO-9001 SORINC.COM
LINEAR = J FIFE
IN DRAWN BY
DATE
3/14/11 M SMITH
PRODUCT CERTIFICATION DRAWING
355.6 ALL DIMENSIONS
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. ARE 1/16 IN
CHECKED BY
J REHM
14.00 NO USE WHATSOEVER OF THE INFORMATION
UNLESSCONTAINED
OTHERWISE SPECIFIED
I HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MM
ENGINEER APPR
LINEAR
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION =
OF SOR. J FIFE
IN
TITLE DATE
0390010
F
1 Connections SCALE: DRAWING SCALE
DO NOT SCALE PRINT
SHEET 1 OF 1
D
D1, 2 E1, F
2 Model Name: MODEL NAME.DRAFT/3/0+
4
G H4 I2 L2 Reset
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
741 19-5/16 (491)
742 13 (330) 3-1/4 (83) 6 (152) 16 (406) 16 (406) 3-3/4 (95) 19-1/2 (495)
743 19-7/8 (505)
802 12-3/4 (324) 3-7/8 (98) 8 (203) 16 (406) 16 (406) 6-3/4 (171) 20-3/4 (527)
1-1/2 Connections
D2 E2 F4 G H4 I2 L2
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
741 19-5/16 (491)
742 13 (330) 3-1/2 (89) 6 (152) 16 (406) 16 (406) 3-3/4 (95) 19-1/2 (495)
743 19-7/8 (505)
802 12-7/8 (327) 4 (102) 8 (203) 16 (406) 16 (406) 6-3/4 (171) 20-3/4 (527)
2 Connections
D2 E2 F4 G H4 I2, 3 L2, 3
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
741 19-5/16 (491)5
742 - - 6 (152) 16 (406) 16 (406) 3-3/4 (95)5 19-1/2 (495)5
743 19-7/8 (505)5
802 13-3/16 (335) 4-5/16 (110) 8 (203) 16 (406) 16 (406) 7-3/4 (197) 21-5/16 (541)
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 41/48
Level Switches 740 & 804 calibration dimensions
DRAWING NUMBER
0390660
MODEL #
Dimensions in this catalog are for reference MODEL
only. #They may be changed without notice. Contact the
SALES ORDER # SALES
PURCHASE ORDER # factory for certified drawings for a particular PURCHASE
model ORDER
number.
#
Dimensions are# expressed as millimeters
LINE ITEM
over inches. (Linear = mm/in.) W designates electrical connection,
146.1
see page 22 for more
* MINIMUM OVERHEAD CLEARANCE
housing information. 5.75
180.9 REQUIRED TO REMOVE HOUSING COVER. 180.9 * MINIMU
7.12 7.12
REQUIRE
101.6 101.6
4.00 4.00 THIS DRAWING WAS CREATED U
THE VERTICAL_MOUNT_ASSY A
FILE 0390660.txt LOCATED ON
*228.6 *228.6K:\$Engineering Services\Concep
W 9.00 W 9.00 THEN THE DRAWING WAS CHA
L
DRAFT ENTITIES.
L
W W
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
ISO-9001 SORINC.COM
DRAWN BY
M SMITH
PRODUCT CERTIFICATION DRAWING
D ALL DIMENSIONS ARE 1/16 IN
CHECKED BY
PROD
J REHM
H UNLESS OTHERWISE SPECIFIED
G
ENGINEER APPROVAL
ALL
MM UN
LINEAR = J FIFE
IN
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
T
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. NO
HER
MAD
E TITLE
1" SW
DIM DWG 200 SERIES SEALED CHAMBER TITLE
(VVT ONLY)
VH DIM DW
F Drawing 0390660 F Drawing 0390661
EO NUMBER: 5090 DRAWING NUMBER REV
VV, VVT
0390660 2
SCALE: DRAWING SCALE EO NUM
DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT A SCALE:
Model Name: MODEL NAME.DRAFT/2/0+ DO
42/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
DRAWING NUMBER
0390662
MODEL # SALES ORDER #
PURCHASE ORDER # LINE ITEM #
DRAWING NUMBER
0390662
Level Switches MODEL #
7.12
740 & 804 chamber dimensions
180.9 * MINIMUM
146.1
5.75
OVERHEAD CLEARANCE
SALES ORDER #
PURCHASE ORDER # REQUIRED TO REMOVE HOUSING COVER. LINE ITEM #
101.6
4.00
180.9 146.1
* MINIMUM OVERHEAD CLEARANCE
7.12 5.75
REQUIRED TO REMOVE HOUSINGTHIS DRA
COVER.
*228.6 101.6 THE VERT
9.00 4.00 FILE 0390
W
L K:\$Engin
THEN TH
W *228.6 DRAFT EN
9.00
W
L 14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
ISO-9001 SORINC.COM
W DRAWN BY
M SMITH
355.6 PRODUCT CERTIFICATION DRAWING CHECKED BY
ALL DIMENSIONS ARE 1/16 IN 14685 W 105TH ST LENEXA, KS 66215
14.00 UNLESS OTHERWISE SPECIFIED
J REHM 913-888-2630
MM ISO-9001 SORINC.COM
ENGINEER APPROVAL
LINEAR = J FIFE
IN DRAWN BY
DATE
3/15/11DRAWING M SMITH
355.6 PRODUCT CERTIFICATION CHECKED BY
ALL DIMENSIONS
THIS DRAWING IS THE EXCLUSIVE ARE 1/16 IN
PROPERTY OF SOR.
14.00 UNLESS OTHERWISE SPECIFIED
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
J REHM
I HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY MMBE ENGINEER APPR
LINEAR =
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. J FIFE
IN
TITLE DATE
Model Reset
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
740 13 (330) 3-1/4 (83) 6 (152) 16 (406) 16 (406) 3-3/4 (95) 20-1/4 (514)
804 12-3/4 (324) 3-7/8 (98) 8 (203) 16 (406) 16 (406) 6-3/4 (171) 21-3/4 (552)
1-1/2 Connection
D2 E2 F4 G H4 I2 L2
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
740 13 (330) 3-1/2 (89) 6 (152) 16 (406) 16 (406) 3-3/4 (95) 20-1/4 (514)
804 12-7/8 (327) 4 (102) 8 (203) 16 (406) 16 (406) 6-3/4 (171) 21-3/4 (552)
2 Connection
D2 E2 F4 G H4 I2, 3 L2, 3
Model
inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
740 - - 6 (152) 16 (406) 16 (406) 3-3/4 (95) 5
20-1/4 (514)5
804 13-3/16 (335) 4-5/16 (110) 8 (203) 16 (406) 16 (406) 7-3/4 (197) 21-3/4 (552)
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 43/48
Level Switches 700 Series unit dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.) W designates electrical connection, see page 22 for more
housing information.
ELECTRICAL CONNECTION W
44/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Level Switches 730 unit dimensions
Dimensions in this catalog are for reference only. They may be changed without notice.
Contact the factory for certified drawings for a particular model number. Dimensions are
expressed as millimeters over inches. (Linear = mm/in.) W designates electrical connection,
see page 22 for more housing information.
Model 730/732 Model 731/733 Model 734/736 Model 735/737
Narrow Differential Narrow Differential Wide Differential SALES PAGE 1 Wide Differential
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
1 2 4 5 6 Switch Position
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 45/48
Level Switches 750 unit dimensions
Dimensions in this catalog are for reference only. They may be changed without notice.
Contact the factory for certified drawings for a particular model number. Dimensions are
expressed as millimeters over inches. (Linear = mm/in.) W designates electrical connection.
Model 750/752 Model 751/753 Model 754/756 Model 755/757
Narrow Differential Narrow Differential Wide Differential Wide Differential SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
NPT A
180.9 180.9
7.12 7.12 FLANGE B
101.6 101.6
4.00 4.00 DIMENSION C SEE CHART
ELECTRICAL CONNECTION W
*306.4
*306.4 12.06
12.06
DIMENSION C
W
W PROCESS
FLANGE
PROCESS CONNECTION SIZE
CONNECTION FLANGE B 150 # 300 # 600 #
NPT A C
D 62.7 67.6 70.6
3"
2.47 2.66 2.78
62.7 70.6 77.0
4"
3048 MINIMUM 3048 MINIMUM 2.47 2.78 3.03
120.0 229 120.0 229 64.3 75.4 86.6
316 SST 316 SST 9.0 6"
9.0 2.53 2.97 3.41
CABLE CABLE
DIMENSION D
HIGH 84.9
HIGH 2-1/2 NPTM
3.34
87.9
3 NPTM
3.46
TOP LOW LOW 222.3
TOP * MINIMUM OVERHEAD CLEARANCE
SWITCH SWITCH 8.75
ACTUATION ACTUATION REQUIRED TO REMOVE HOUSING COVER
HIGH HIGH 316 SST
316 SST DISPLACER 14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
DISPLACER SORINC.COM
ISO-9001
SHEET 1 OF 1
3
DWG SIZE
* Minimum 8-3/4 (222 mm) overhead clearance required to remove housing cover.
Model Name: 0390682.ASSEM/2/0
Reset Form
B C D E F G H
Switch
Position
46/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.
Form 912 (09.17) SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 47/48
SOR Inc. | Lenexa, KS USA | 913-888-2630 | Fax 913-888-0767 | SORInc.com
REGIONAL OFFICES
China Middle East
SOR China | Beijing, China | [email protected] SOR Measurement & Control Equipment Trading DMCC | Dubai, UAE
+86 (10) 5820 8767 | Fax +86 (10) 58 20 8770 [email protected] | +971 4 363 3637 | Fax + 1 913 312 3596
48/48 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (09.17) SOR Inc.