0% found this document useful (0 votes)
270 views3 pages

Strap Footing Working 1

The document discusses the design of footings and a strap beam. It provides calculations for the design of two footings, including dimensions, reinforcement requirements, and shear and punching checks. It also includes calculations for the design of a strap beam connecting the two footings, such as dimensions, shear check, and reinforcement requirements.

Uploaded by

Mainali Ishu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
270 views3 pages

Strap Footing Working 1

The document discusses the design of footings and a strap beam. It provides calculations for the design of two footings, including dimensions, reinforcement requirements, and shear and punching checks. It also includes calculations for the design of a strap beam connecting the two footings, such as dimensions, shear check, and reinforcement requirements.

Uploaded by

Mainali Ishu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

strap beam

PL1= 303 KN PL2= 404 KN PL1 L PL2


b1= 0.3 m b2= 0.3 m
l1= 0.3 m l2= 0.3 m
q(all)net= 120 KN/m2
e

b1

b2
Size of footing 1= 1.52 X 1.52

assume e= 0.61 m
K= 3.05 m l1 l2
R1= 378.75 m
R2= 328.25 m

Design of footing 1 K1=0.766 K2= 172.3


B1= 1.52 m
q(act)= 118.656 KN/m2 10
L1= 2.1 m
X1= 0.9 m X2= 1.22 3.04878
T1= 0.3 m
M= 48.05569 KN.m
d= 0.17 m
d(act)= 0.23 m t1= 0.30 m
check of (o.w.s) Rienforcement d= 12 mm
Q(o.w.s)= 93.14497 KN As= 1213 mm2
q(o.w.s)= 404.9781 < 700KN/m2 ok n= 11
selecte 612 /m'
Design of footing 2
L=LC+2x= 1.52 m B=bc+2x= 1.52 m Af=B*L= 2.3104 m2

X= 0.800214 m X= 0.85 m

q(all)net= Pc/(2x+bc)(2x+Lc) = 90.89 KN/m2

q(act)= 142.07 KN/m2


Find footimg thicness
K1= 0.766 K2= 172.3
M=q(act)*(x^2)/2= 51.32458 KN.m/m'

d= 0.17 m t= 0.24 m t= 0.40 m


d(act)= 0.33 m
check of one way shear check of punshing
Qp= 56.38955 KN
Q(o.w.s.)= 97.32 KN Ap= 0.8316 m2
q(o.w.s.)= 294.91 KN/m2 < 700KN/m2 ok qp= 67.80851 kN/m2 < 900KN/m2 ok

reinforcment
D= 12 mm
As= 903 /m' select 712 /m'
n= 8
Design of strap beam
1010 KN/m' 2.1 1346.667 1.52

Ass. b= 0.3 m 249.1776 215.9539 KN/m'


KN/m'
d= 0.52 m 0.3 1.22 0.68 0.85 0.3 0.85
t= 0.6 m
d(act) = 0.53
check for shear 0.916 75.75
q= 476.4151 KN/m2
< 700KN/m2 ok
use 4br10@200mm
228.2467
Reinforcment
D= 16 mm Mtop= 138.774 KN.m
AS(top)= 1520 mm2
n= 8 select 625
AS(bottom)= 304 mm2
D= 16 mm
n= 2 select 216
Ash= 0.0144 n= 1 select 412 D= 12 mm

You might also like