MiraCel II 10 Hefa Filter

This document provides specifications for MiraCel II medium high efficiency air filters. It describes key features such as available efficiency levels ranging from 60-65% to 90-95%, a 4" depth, lightweight and compact design. Charts show initial pressure resistance levels up to 165 Pa and recommended final resistance of 375 Pa for various filter sizes and efficiency levels. Dimensions, materials, and certifications are also specified.

Uploaded by

ujangaep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
161 views2 pages

MiraCel II 10 Hefa Filter

This document provides specifications for MiraCel II medium high efficiency air filters. It describes key features such as available efficiency levels ranging from 60-65% to 90-95%, a 4" depth, lightweight and compact design. Charts show initial pressure resistance levels up to 165 Pa and recommended final resistance of 375 Pa for various filter sizes and efficiency levels. Dimensions, materials, and certifications are also specified.

Uploaded by

ujangaep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MEDIUM HIGH EFFICIENCY AIR FILTER SERIES

Mini-Pleat Type Medium High Efficiency Filter MiraCel II

MiraCel II
Available in three efciency 90 - 95%, 80 - 85% and 60 65%
4 deep high efciency, light weight, reduce shipping cost and storage space
Easy handling, installation and removal
Highly moisture resistance / sturdy beverage board frame
Microglass paper with water repellent binder
Available with Miracel II with antimicrobial

Specification
Pressure Resistance (Pa)
Nominal Size Outer Dimension Air Flow Average Efciency
WHD (in) WHD (mm) (m3/min) (%) Recommended
Initial
Final Resistance (Pa)
12x24x4 289x594x95 28 F8
20x24x4 492x594x95 46 90-95% 165
24x24x4 594x594x95 56 MERV 14
12x24x4 289x594x95 28 F7
20x24x4 492x594x95 46 80-85% 145 375
24x24x4 594x594x95 56 MERV 13
12x24x4 289x594x95 28 F6
20x24x4 492x594x95 46 60-65% 95
24x24x4 594x594x95 56 MERV 11

Measurement method : Ashrae 52.2 & EN 779 Inammability : UL Class 900 Other than standard dimension please discuss

Operating Condition Material


Usage Temperature Limit (Continuous) 70C Cellside Beverage Board / Galvalume / Galvanised steel
Usage Humidity Limit (Continuous) 95%RH Media Fiber Glass
Separator Hot Melt
Sealant Glue

Outer Dimension Diagram Air Capacity vs Initial Pressure Resistance


Initial Resistance vs Air Flow Rate

200

180

165
160

145
140

124
120
Resistance (Pa)

108 F8
H 100
95
F7
F6

80
80

67 69
60

40 42 44

33

20
21
W
D 0
0 10 20 30 40 50 60

Rated Air Flow (CMM)

Specication, appearance and content are subject to change without prior notice. 02 MAY 2017 UL Certified 8327
MEDIUM HIGH EFFICIENCY AIR FILTER SERIES

Mini-Pleat Type Medium High Efficiency Filter MiraCel II

MiraCel II MH
Available in three efciency 90 - 95%, 80 - 85% and 60 65%
Available for SH, DH, and NH
4 deep high efciency, light weight, reduce shipping cost and storage space
Easy handling, installation and removal
G.I steel frame / moisture resistance beverage frame
Microglass paper with water repellent binder
Also with Miracel II with antimicrobial

Specification
Pressure Resistance (Pa)
Nominal Size Outer Dimension Air Flow Average Efciency
WHD (in) WHD (mm) (m3/min) (%) Recommended
Initial
Final Resistance (Pa)
12x24x4 289x594x105 28 F8
20x24x4 492x594x105 46 90-95% 165
24x24x4 594x594x105 56 MERV 14
12x24x4 289x594x105 28 F7
20x24x4 492x594x105 46 80-85% 145 375
24x24x4 594x594x105 56 MERV 13
12x24x4 289x594x105 28 F6
20x24x4 492x594x105 46 60-65% 95
24x24x4 594x594x105 56 MERV 11
Measurement method : Ashrae 52.2 & EN 779 Inammability : UL Class 900 Other than standard dimension please discuss

Operating Condition Air Capacity vs Initial Pressure Resistance


Usage Temperature Limit (Continuous) 70C Initial Resistance vs Air Flow Rate

Usage Humidity Limit (Continuous) 95%RH 200

180

165

Outer Dimension Diagram


160

145
140

124
120
Resistance (Pa)

108 F8
100 F7
95 F6

80
80

W D 60
67 69

40 42 44

33

20
21

H 0
0 10 20 30 40 50 60

Rated Air Flow (CMM)

Japan Air Filter Malaysia Sdn Bhd


Lot 4, Jalan Halba 16/16, Seksyen 16,
Shah Alam Industrial Estate, 40200 Shah Alam,
Selangor, Malaysia
Office : +603 5523 9841 Fax : +603 5510 0266

Specication, appearance and content are subject to change without prior notice. 02 MAY 2017 UL Certified 8327