Project: Bukit Batok Plaza Subject: Anchorage Length 1

This document summarizes the design of anchorage length for reinforcement bars in Bukit Batok Plaza. It provides the influencing factors for anchorage length including anchorage type, shape of bar, concrete cover, transverse reinforcement, transverse pressure, material properties, and bond condition. Based on these factors and the minimum required anchorage length equation, the design anchorage length is calculated to be 23.81 mm for the given rebar diameter, concrete strength, and steel yield strength. The provided anchorage length of 200 mm is sufficient.

Uploaded by

zin nyo thet
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
139 views

Project: Bukit Batok Plaza Subject: Anchorage Length 1

This document summarizes the design of anchorage length for reinforcement bars in Bukit Batok Plaza. It provides the influencing factors for anchorage length including anchorage type, shape of bar, concrete cover, transverse reinforcement, transverse pressure, material properties, and bond condition. Based on these factors and the minimum required anchorage length equation, the design anchorage length is calculated to be 23.81 mm for the given rebar diameter, concrete strength, and steel yield strength. The provided anchorage length of 200 mm is sufficient.

Uploaded by

zin nyo thet
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Project: Bukit Batok Plaza a1

Subject: Anchorage Length Tension Compression


Anchorage Type 1 Straight 1 1
Tension(1), Compression(2) Non-straight 0.7 1

Shape of bar cd 100 Straight 1


straight bars(1), Bent or hooked bars (2), Loop bars (3) 1 50 Bent 2
Influencing factor for shape of bar, a1 = 1 50 Looped 3

bar diameter, f = 10 mm a2
bar spacing, a = 200 mm Tension Compression
clear side cover, c1 = 50 mm Straight 0.7 1 -3.5
clear bottom cover, c = 50 mm Non-straight 0.7 1 -0.05
cd = 100 mm
Influencing factor for concrete cover, a2 = 0.7 a2 Tension Compression
1
Transverse reinforcement welded to main reinforcement (Y/N)(1/2) 2
bar loaction : Corner (1), Inner(2), Outer(3) 2

Astmin, cross sectional area of the minimum transverse reinforcement = 19.63 mm2
Ast, cross sectional area of the transverse reinforcement = 393 mm2
As , area of a signle anchored bar with maximum bar diameter = 78.5 mm2
Influencing factor for confinement by transverse reinforcement, a3 = 1
Influencing factor for confinement by transverse reinforcement, a4 = 1

r, transverse pressure (Mpa) at ultimate limit state along lbd =


Influencing factor for confinement by transverse pressure, a5 = 1

Yield strength of the bar, f yk = 460 N/mm2


Designed concrete strength, fck = 40 N/mm2
partial safety factor, gs = 1.15
Design stress of the bar, ssd , fyk/gs= 400 N/mm2

bond condition - Good (G), Poor (P) = G


h1 = 0.7
h2 = 1
design concrete tensile strength, fctd = fck / gc = 26.7 N/mm2
Design ultimate stress, fbd = 2.25h1h2fctd = 42 N/mm2

Basic anchorage length, l b,r,q,d = f/4 (ssd/fbd) = 23.81 mm Tension Compression


Minimum anchorage length, Lb,min = 14.29 mm 714.2857143 1428.571
Design Anchorage Length, lbd = a1a2a3a4a5 lb,rqd = 23.81 mm

Base moment, Muls = 4.86 KN-m


lever arm, x = 200 mm
No of bolt = 2
Tension/bolt = 12.15 KN
Designed bond stress = 2.4 N/mm2
(for fck = 35 N/mm2)
Required bonding length, lb,req = 161.2 mm
Use 161.23 mm Anchorage Length
Provided 200 mm Anchorage Length