The document provides calculations to determine the quick opening closure size for a test pressure of 30 bars in a bore with a 200mm diameter inside. It calculates the internal force based on the pressure and bore area as 94,200N. No bolt size is determined but the minimum tensile strength is given as 75,718 lbs.

Uploaded by

Wijayanto Bekasi
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views

Qoc Calculation

The document provides calculations to determine the quick opening closure size for a test pressure of 30 bars in a bore with a 200mm diameter inside. It calculates the internal force based on the pressure and bore area as 94,200N. No bolt size is determined but the minimum tensile strength is given as 75,718 lbs.

Uploaded by

Wijayanto Bekasi
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

PERHITUNGAN QUICK OPENING CLOSURE SIZE 8 " #300

Data :
P : Test Pressure 30 Bars
30 kg/cm2
3 N/mm2
D : Dia.Inside Bore 200 mm
A : Area
: (3.14/4)*D^2
: (3.14/4)*200^2 31,400 mm2
0.0314 m2
314 cm2
F : Internal Force
: P*A
: 30*314 9,420 kg
94,200 N
Db : Bolt size 1 inch
S : Min Tensile Strenght 75,718 Lbs
34,338 kg
:
:
:
: