MCCB NSX
MCCB NSX
525 V - 22 35 35 40 50 - 22 35 35 40 50 - 22 35 35 40 50 20 22 35 40 50 20 22 35 40 50
660/690 V - 8 10 10 15 20 - 8 10 10 15 20 - 8 10 10 15 20 10 10 20 25 35 10 10 20 25 35
Service breaking capacity (kA rms)
lcs AC 50/60 Hz 220/240 V 40 85 90 100 120 150 40 85 90 100 120 150 40 85 90 100 120 150 40 85 100 120 150 40 85 100 120 150
380/415 V 25 36 50 70 100 150 25 36 50 70 100 150 25 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150
440 V 20 35 50 65 90 130 20 35 50 65 90 130 20 35 50 65 90 130 30 42 65 90 130 30 42 65 90 130
500 V 7.5 12.5 36 50 65 70 15 30 36 50 65 70 15 30 36 50 65 70 25 30 50 65 70 25 30 50 65 70
525 V - 11 35 35 40 50 - 22 35 35 40 50 - 22 35 35 40 50 10 11 11 12 12 10 11 11 12 12
660/690 V - 4 10 10 15 20 - 8 10 10 15 20 - 8 10 10 15 20 10 10 10 12 12 10 10 10 12 12
Durability (C-O cycles) Mechanical 50000 40000 20000 15000 15000
Electrical 440 V In/2 50000 20000 20000 12000 8000
In 30000 10000 10000 6000 4000
690 V In/2 20000 15000 10000 6000 6000
In 10000 7500 5000 3000 2000
Characteristics as per Nema AB1
Breaking capacity (kA rms) AC 50/60 Hz 240 V 40 85 90 100 120 150 40 85 90 100 120 150 40 85 90 100 120 150 40 85 100 120 150 40 85 100 120 150
480 V 20 35 50 65 90 130 20 35 50 65 90 130 20 35 50 65 90 130 30 42 65 90 130 30 42 65 90 130
600 V - 8 20 35 40 50 - 20 20 35 40 50 - 20 20 35 40 50 - 20 35 40 50 - 20 35 40 50
Characteristics as per UL 508
Breaking capacity (kA rms) AC 50/60 Hz 240 V - 85 85 85 - - - 85 85 85 - - - 85 85 85 - - 85 85 85 - - 85 85 85 - -
480 V - 25 50 65 - - - 35 50 65 - - - 35 50 65 - - 35 50 65 - - 35 50 65 - -
Compact NSX400/630.
600 V - 10 10 10 - - - 10 10 10 - - - 15 15 15 - - 20 20 20 - - 20 20 20 - -
Protection and measurements
Short-circuit protection Magnetic only b b b b b
Overload / short-circuit protection Thermal magnetic b b b - -
Electronic b b b b b
with neutral protection (Off-0.5-1-OSN) (1) b b b b b
with ground-fault protection b b b b b
with zone selective b b b b b
interlocking (ZSI) (2)
Display / I, U, f, P, E, THD measurements / interrupted-current measurement b b b b b
Options Power Meter display on door b b b b b
Operating assistance b b b b b
Counters b b b b b
Histories and alarms b b b b b
Metering Com b b b b b
Device status/control Com b b b b b
Earth-leakage protection By Vigi module b b b b b
By Vigirex relay b b b b b
Installation / connections
Dimensions and weights
Dimensions (mm) Fixed, front connections 2/3P 105 x 161 x 86 105 x 161 x 86 105 x 161 x 86 140 x 255 x 110 140 x 255 x 110
WxHxD 4P 140 x 161 x 86 140 x 161 x 86 140 x 161 x 86 185 x 255 x 110 185 x 255 x 110
Weight (kg) Fixed, front connections 2/3P 2.05 2.2 2.4 6.05 6.2
4P 2.4 2.6 2.8 7.90 8.13
(1) OSN: Over Sized Neutral protection for neutrals carrying Connections
high currents (e.g. 3rd harmonics). Connection terminals Pitch With/without spreaders 35/45 mm 35/45 mm 35/45 mm 45/52.5 mm 45/52.5 mm
(2) ZSI: Zone Selective Interlocking using pilot wires. 45/70 mm 45/70 mm
(3) 2P circuit breaker in 3P case for B and F types, only with Large Cu or Al cables Cross-section mm² 300 300 300 4 x 240 4 x 240
thermal-magnetic trip unit.
A-10 A-11
Compact NS Protection of distribution Compact NS Protection of distribution
systems systems
Compact NS circuit breakers Compact NS circuit breakers
from 630 up to 3200 A from 630 up to 3200 A
DB112530
Compact circuit breakers NS630b NS800 NS1000 NS1250 NS1600 NS1600b NS2000 NS2500 NS3200
Number of poles 3, 4 3, 4 3, 4 3, 4 3, 4
Control manual toggle b b b b b
direct or extended rotary handle b b b b -
electric b (except LB) b b b -
Type of circuit breaker N H L LB N H L N H N H N H
Connections fixed front connection b b b - b b b b b b b b b
rear connection b b b b b b b b b b b - -
front connection with bare cables b b - - b b - b b - - - -
withdrawable (on chassis) front connection b b b b b b b b b b b - -
rear connection b b b b b b b b b b b - -
Electrical characteristics as per IEC 60947-2 and EN 60947-2
Rated current (A) In 50 °C 630 800 1000 1250 1600 1600 2000 2500 3200
65 °C (1) 630 800 1000 1250 1510 1550 1900 2500 2970
Rated insulation voltage (V) Ui 800 800 800 800 800
Rated impulse withstand voltage (kV) Uimp 8 8 8 8 8
Rated operational voltage (V) Ue AC 50/60 Hz 690 690 690 690 690
Compact NS800L Type of circuit breaker N H L LB N H L N H N H N H
Ultimate breaking capacity (kA rms) lcu AC 220/240 V 50 70 150 200 50 70 150 50 70 50 70 85 125
50/60 Hz 380/415 V 50 70 150 200 50 70 150 50 70 50 70 70 85
E45178R_68
A-14 A-15