You are on page 1/ 242

CAT.

ES11-84 B

4/5 Port Solenoid Valve

Improved pilot valve


Pilot valve cover is stronger using stainless steel.
Mounting thread is also reinforced from size M1.7 to M2.

앬 Flow Characteristics
Flow characteristics
Series
C [(dm3/s·bar)] b Cv
SYJ3000 0.46 0.36 0.12
SYJ5000 0.83 0.32 0.21
Cover (stainless steel) SYJ7000 2.9 0.35 0.74
Rubber Seal
4/5 Port Solenoid Valve

Series SYJ3000/5000/7000
Variations
Option
Sonic conductance: Type of Manual
Series Voltage Electrical entry
C [dm3/(s.bar)] actuation With light/surge override
voltage suppressor

SYJ3000 For DC For DC

Effective area  With surge voltage


0.9 mm2  24 VDC suppressor
Grommet
4/2 → 5/3 12 VDC
{ (A/B → EA/EB) } 6 VDC
5 VDC
P. 1 3 VDC
–+

SYJ5000
Body ported

0.47 L plug connector  With light/ surge


4/2 → 5/3
{ (A/B → EA/EB) } voltage suppressor

P. 23
–+

SYJ7000 2 Position
 Single
2.4
 Double M plug connector
4/2 → 5/3
{ (A/B → EA/EB) }
+–
For AC
P. 47  Non-locking
3 Position push type
SYJ3000  Closed
 100 VAC /60 Hz
50

110 VAC 50/60 Hz


0.46 center 200 VAC 50/60 Hz
4/2 → 5/3
{ (A/B → EA/EB) }  Exhaust

center
220 VAC 50/60 Hz

 Pressure For AC Note)


center  Push-turn
P. 1  With light/surge locking
Base mounted

DIN terminal voltage suppressor slotted type

SYJ5000
0.83  Push-turn
4/2 → 5/3
{ (A/B → EA/EB) } locking
lever type
(SYJ5000, 7000
only)
P. 23

SYJ7000 M8 connector

2.9
4/2 → 5/3
{ (A/B → EA/EB) }
P. 47
Note) All AC voltage models have built-in surge voltage suppressor.

Front matter 1
Series SYJ3000/5000/7000

Manifold Variations
A, B port size Manifold option

A, B port With one-touch fitting Individual Individual


Valve series location SUP EXH Interface Flat ribbon cable manifold
M3 M5 1/8 Applicable tubing O.D
spacer spacer regulator
ø4 ø6 ø8 N3 N7 N9 assembly assembly

SYJ3000  — — — — — — — — — — — 
Body ported

SYJ5000 Top —  —   —   —   — 

SYJ7000 — —  —   —   —  — 

Side   —  — —  — — 
SYJ3000 — — —
Bottom — — — — — — — — — —
Base mounted

Side —  —   —   — 
SYJ5000   
Bottom —  — — — — — — — (P port —
regulation)

Side — —  —   —   —
  
SYJ7000
Bottom — —  — — — — — — (P port —
regulation)

Body ported Type 21P


A, B port Individual SUP
spacer assembly
-+
-+ P port
R
P
R

R port P

Base mounted
P port

Type 32P
Individual EXH
R port
A, B port
spacer assembly
R2

-+
-+ R1
R
R port
P
A, B port
P port Mixed mounting of 3 port
valves and 4, 5 port valves

-+
Interface 4, 5 port valve
3 port valve
-+

R
R port regulator
P
A
A, B port B
P port
-+
-+

R
P
A
-+ B
-+

B
P
R R port
A, B port A For detailed specifications about
B
P port SYJ3000, refer to page 14. For
SYJ5000, refer to page 38, and for
SYJ7000, refer to page 61.

Front matter 2
Rubber Seal
4/5 Port Solenoid Valve

Series SYJ3000 For details about certified products conforming to


Specifications international standards, visit us at www.smcworld.com.

Fluid Air
2 position single 0.15 to 0.7
Operating pressure range
MPa 2 position double 0.1 to 0.7
3 position 0.2 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing. Refer to back page 3.)
Response time (ms) Note 1) 2 position single, double 15 or less
(at 0.5 MPa) 3 position 30 or less
Max. operating 2 position single, double 10
frequency (Hz) 3 position 3
Body ported
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Individual exhaust for the pilot valve, Common exhaust for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
Note 2)
Shock/Vibration resistance (m/s2) 150/30
Enclosure Dust proof (∗ M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge
voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the
main valve and armature in both energized and de-energized states every once for each
condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to
axis and right angle directions of the main valve when pilot signal is ON and OFF. (Value in
the initial state)
Base mounted
Solenoid Specifications
JIS Symbol
5 port 4 port (manifold)
Electrical entry Gromet (G), (H), L plug connector (L),
2 position single 2 position single M plug connector (M), M8 connector (W)
(B) (A) (B) (A)
2 4 2 4 DC 24, 12, 6, 5, 3
Coil rated voltage (V)
AC 50/60 Hz 100, 110, 200, 220
3 1 5
(R) (P) (R)
1 3 Allowable voltage fluctuation ±10% of rated voltage ∗
(P) (R)
2 position double 2 position double Standard 0.35 (With light: 0.4)
(B) (A) (B) (A) Power consumption (W) DC
2 4 2 4 With power saving circuit 0.1 (With light only)
100 V 0.78 (With light: 0.81)
3 1 5 0.86 (With light: 0.89)
(R) (P) (R) 1 3 110 V
(P) (R) [0.94 (With light: 0.97)]
[115 V]
3 position closed center 3 position closed center Apparent power VA ∗ AC
(B) (A) (B) (A) 200 V 1.18 (With light: 1.22)
2 4 2 4
220 V 1.30 (With light: 1.34)
[230 V] [1.42 (With light: 1.46)]
3 1 5
(R) (P) (R) 1 3
(P) (R) Surge voltage suppressor Diode (Non-polarity type: Valistor)
3 position exhaust center 3 position exhaust center Indicator light LED
(B) (A) (B) (A)
2 4 2 4 ∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VDC and 230 VDC, the allowable voltage is –15% to +5% of rated voltage.
∗ S, Z and T type (with power saving circuit) should be used within the following allowable voltage fluctuation range due to
3 1 5 a voltage drop caused by the internal circuit. S and Z type: 24 VDC: –7% to +10%, 12 VDC: –4% to +10%
(R) (P) (R) 1 3
(P) (R) T type: 24 VDC: –8% to +10%, 12 VDC: –6% to +10%
3 position pressure center 3 position pressure center
(B) (A)
2 4
(B) (A)
2 4
Bracket Mounting
q Insert the lower hook of the mounting bracket into w Press the valve and mounting bracket together
3 1 5
(R) (P) (R) 1 3 the groove on the bottom of the valve as shown. until the upper hook of the bracket snaps into
(P) (R) place in the groove on top of the valve.

Made to Order
(For details, refer to page 79.)

1
Series SYJ3000

Flow Characteristics/Weight

Port size Weight (g) Note 3, 4) Effective Flow characteristics Note 2)


Valve model Type of actuation 1, 5, 3 4, 2 L/M plug M8 area 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB)
Grommet
(P, EA, EB) (A, B) connector connector (mm2) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv
SYJ314 Single 62 (36) 63 (37) 67 (41)
2 position — 0.46 0.36 0.12 0.46 0.35 0.12
5 port SYJ324 Double 79 (53) 81 (55) 89 (63)
Base mounted SYJ334 Closed center M5 x 0.8 M5 x 0.8 — 0.47 0.33 0.12 0.47 0.31 0.12
(with sub-plate) SYJ344 3 position Exhaust center 82 (56) 84 (58) 92 (66) — 0.36 0.39 0.10 0.59 [0.40] 0.43 [0.33] 0.16 [0.11]
SYJ354 Pressure center — 0.58 [0.32] 0.42 [0.33] 0.16 [0.080] 0.46 0.32 0.11
SYJ312 Single 36 37 41
2 position
SYJ322 Double 53 55 63
5 port
SYJ332 Closed center M3 x 0.5 M3 x 0.5 0.9
Body ported
SYJ342 3 position Exhaust center 56 58 66
SYJ352 Pressure center
Note 1) SYJ313 Single 36 37 41
4 Port 2 position —
SYJ323 Double 53 55 63
Base mounted
SYJ333 Closed center 1/8 M5 x 0.8 —
(For manifold
SYJ343 3 position Exhaust center 56 58 66 —
base only)
SYJ353 Pressure center —
Note 1) Dedicated for manifold base. For details, refer to page 11.
Note 2) [ ] denotes the normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 3) ( ): Without sub-plate.
Note 4) For DC voltages. For AC voltages add 3 g to the weight of the single solenoid and 6 g to the
weight of the double solenoid and 3 position types.

Cylinder Speed Chart


Use as a guide for selection.
Please confirm the actual conditions with SMC
Body Ported Sizing Program.
Bore size
Series CJ2 Series CM2
Average
Pressure 0.5 MPa Pressure 0.5 MPa
Series speed Load rate: 50% Load rate: 50%
(mm/s) Stroke 60 mm Stroke 300 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40
800
700 Perpendicular, upward actuation
600
500 Horizontal actuation
SYJ3120-M3 400
300
200
100
0

Base Mounted
Bore size
Series CJ2 Series CM2
Average
Pressure 0.5 MPa Pressure 0.5 MPa
Series speed Load rate: 50% Load rate: 50%
(mm/s) Stroke 60 mm Stroke 300 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40
800
700 Perpendicular, upward actuation
600
500 Horizontal actuation
SYJ3140-M5 400
300
200
100
0

∗ Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
∗ Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
∗ Load factor: ((Load weight x 9.8) /Theoretical force) x 100%

Conditions
Body ported Series CJ2 Series CM2 Base mounted Series CJ2 Series CM2
Tubing bore x Length ø4 x 1 m Tubing bore x Length ø6 x 1 m
SYJ3120-M3 Speed controller AS1301F-04 SYJ3140-M5 Speed controller AS2001F-06 AS2301F-06
Silencer AN120-M5 Silencer AN120-M5

2
Series SYJ3000

How to Order
Light/surge voltage suppressor Bracket
Type of actuation Nil Without light/surge voltage suppressor Nil: Without bracket
1 2 position single solenoid S With surge voltage suppresor F: With bracket
2 2 position double solenoid Z With light/surge voltage suppressor
3 3 position closed center R With surge voltage suppressor (Non-polar type)
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
5 3 position pressure center ∗ For AC voltage valves there is no “S” option.
-+
It is already built-in to the rectifier circuit.
∗ For type “R” and “U”, DC voltage is only
available. Single Double
∗ Power saving circuit is only available in the ∗ Brackets cannot
5 port Rated voltage "Z" type. be retrofitted.
DC AC (50/60 Hz) Note) • The double solenoid mounting
bracket is supplied unattached.
5 24 VDC 1 100 VAC • To order the double solenoid
6 12 VDC 2 200 VAC bracket for use with a single
V 6 VDC 3 110 VAC [115 VAC] solenoid valve, order the single
S 5 VDC 4 220 VAC [230 VAC] solenoid valve without a bracket
and order the bracket (VJ3000-
R 3 VDC ∗ For type W, DC voltage is only available. 13-1) separately.
(Type 20 Manifold)
(Example) SYJ3120-5M-M3
VJ3000-13-1

Body ported SYJ3 1 2 0 5 M M3


Base mounted SYJ3 2 3 0 5 M (Manifold use only)
(4 port)

Base mounted SYJ3 2 4 0 5 M


(5 port)

4 port Coil specifications Manual override Port size


Nil Standard
Nil: Non-locking push type Nil: Without sub-plate
With power saving circuit
T
(24, 12 VDC only)
∗ Power saving circuit
is not available in the
For manifold type
case of W type.
31, S31, 32, S32
5 port Body option
0: Pilot valve individual 3: Common exhaust type
(With gasket and screws)
exhaust for the pilot for main and pilot valve
D: Push-turn locking slotted type
valve
M5: With M5 port sub-plate

For sub-plate,
manifold type 41, S41, 46, S46 R port P, E port R port P, E port

Electrical entry
24, 12, 6, 5, 3 VDC
24, 12, 6, 5, 3 VDC
100,110, 200, 220 VAC
Grommet L plug connector M plug connector M8 connector E: Push-turn locking lever type
G: Lead wire L: With lead wire M: With lead wire MN: Without WO: Without
length 300 mm (Length 300 mm) (Length 300 mm) lead wire connector cable

+– +–

+

–+

H: Lead wire LN: Without LO: Without MO: Without W: With connector
length 600 mm lead wire connector connector cable Note 1)

+

–+ Note) When placing an order for body ported
solenoid valve as a single unit, mounting
bolt for manifold and gasket are not
attached. Order them separately, if
∗ LN, MN type: with 2 sockets.
necessary. (For details, refer to page 15.)
∗ For connector cable of M8 connector, refer to back page 10.
Note 1) Enter the cable length symbols in . Please be sure
to fill in the blank referring to back page 10.
3
Series SYJ3000

Construction
(A)(B) (A)(B)
2 position single 4 2 2 position double 4 2

5 1 3 5 1 3
(R)(P)(R) (R)(P)(R)

e t qr w wq t r
(A) (B) (A) (B)
4 2 4 2

u u
5 1 3 5 1 3
(R) (P) (R) (R) (P) (R)
y
3 position closed center/exhaust center/pressure center
3 position closed center
(A)(B)
4 2

w t q r
5 1 3
(R)(P)(R)
(A) (B)
3 position exhaust center 4 2
(A)(B)
4 2

5 1 3
(R)(P)(R)
3 position pressure center
(A)(B)
5 1 3
u
4 2
(R) (P) (R)
5 1 3 (This figure shows a closed center type.)
(R)(P)(R)

Component Parts Replacement Parts


No. Description Material Note No. Description No. Note
1 Body Zinc die-casted White 6 Sub-plate SYJ3000-22-1 Zinc die-casted
2 Piston plate Resin White 7 Pilot valve V111 (T) -
3 End cover Resin White
4 Piston Resin
5 Spool valve assembly Alminum, H-NBR How to Order Connector Assebmly
How to Order Pilot Valve Assembly for L/M Plug Connector

V111 5 G For DC : SY100-30-4A-

Coil specifications
Light/surge voltage suppressor
Nil Without light/surge voltage suppressor
For 100 VAC : SY100-30-1A-
Nil Standard S With surge voltage suppresor

T
With power saving circuit Z With light/surge voltage suppressor For 200 VAC : SY100-30-2A-
(24, 12 VDC only) With surge voltage suppressor
R (Non-polar type)
∗ Power saving
circuit is not With light/surge voltage suppressor
For other
voltages of AC
: SY100-30-3A-
available in the U
(Non-polar type)
case of W type.
∗ For AC voltage valves there
is no “S” option. It is already
Without lead wire : SY100-30-A
built-in to the rectifier circuit. (with connector and Lead wire length
∗ For type “R” and “U”, DC 2 of sockets only)
voltage is only available. Nil 300 mm
∗ Power saving circuit is only 6 600 mm
available in the "Z" type. 10 1000 mm
Rated voltage
15 1500 mm
5 24 VDC Electrical entry 20 2000 mm
6 12 VDC G Grommet, 300 mm lead wire 25 2500 mm
V 6 VDC 30 3000 mm
S H Grommet, 600 mm lead wire
5 VDC 50 5000 mm
R 3 VDC L With lead wire
L plug
1 100 VAC 50/60 Hz LN Without lead wire
connector
2 200 VAC 50/60 Hz LO Without connector How to Order M8 Connector Cable
110 VAC 50/60 Hz M With lead wire
3 M plug
[115 VAC 50/60 Hz] MN Without lead wire
4 220 VAC 50/60 Hz MO
connector
Without connector V100-49-1-
[230 VAC 50/60 Hz] WO M8 Without connector cable
∗ For type W, DC W connector With connector cable Note 1)
voltage is only Cable length
∗ For connector cable of M8 connector,
available. refer to back page 10. 1 300 mm
Note 1) Enter the cable length symbols in 2 500 mm
. Please be sure to fill in the 3 1000 mm
blank referring to back page 10. 4 2000 mm
7 5000 mm
4
Series SYJ3000

2 Position Single [ ]: AC

Grommet (G), (H): SYJ3120- GH -M3 With bracket:


SYJ3120- GH -M3-F
G: Approx. 300
54.4 [56.6] H: Approx. 600
(Lead wire length) 28.4
32.2 2-ø3.5 22 3.2
(For mounting)
13.2 7.1

16.4
10
- +
8.2
4

A B

11.5 19.3
7 Manual override

M5 x 0.8 2-ø1.8 34.7 [41.7]


(A, B port) (For monifold mounting) (Light/surge voltage suppressor)

28 [35]
-+
22.1

54.4 [56.6]
13.5

12.6
15

2
R P R (Bracket) 15
11
10

ø1.2 22.1
7 7 (PE port)
15 M5 x 0.8
(P, R port)

L plug connector (L): M plug connector (M): M8 connector (WO):


SYJ3120-L-M3 (-F) SYJ3120-M-M3 (-F) SYJ3120-WO-M3 (-F)
Approx. 300
(Lead wire length)

28 [35]

12.6
M8 x 1 32.5
15
Approx. 300 39.1 [46.1]
(Lead wire length)
64.3 [66.5]

54.5 [56.7]

63.4
56
49.5
(2)

(2)
(2)

13.5 13.5 13.5


15 15 15
22.1 22.1 22.1

Refer to back page 11 for


dimentions with connector cable.

5
Series SYJ3000

2 Position Double [ ]: AC

G
Grommet (G), (H): SYJ3220- H -M3 (-F)

G: Approx. 300
78.8 [83.2] H: Approx. 600
(Lead wire length)
34.4
7.1
1.8

4
8.2
A B

M3 x 0.5 7 Manual override


(A, B port)
2-ø1.8
(For monifold mounting)

2-ø3.2 equivalent Bracket (Light/surge voltage suppressor)


(For mounting) (18.5)

28 [35]
(18.5)
22.1

-+

13.5

12.6
15

(11.5)
0.5

R P R
10

14 ø1.2
(PE port)
M5 x 0.8
(P, R port)

L plug connector (L): M plug connector (M): M8 connector (WO):


SYJ3220-L-M3 (-F) SYJ3220-M-M3 (-F) SYJ3220-WO-M3 (-F)
Approx. 300
(Lead wire length)

28 [35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1 [46.1]
(Lead wire length)

13.5 13.5 13.5


98.6[103]

79 [83.4]

96.8
69

82

15
22.1 15
15
22.1
22.1

Refer to back page 11 for


dimentions with connector cable.

6
Series SYJ3000

3 Position Closed Center/Exhaust Center/Pressure Center [ ]: AC

3
Grommet (G), (H): SYJ3 20- H -M3 (-F)
G
4
5

G: Approx. 300
91.7 [96.1] H: Approx. 600
40.2 [42.4] (Lead wire length)

29.3 18
1.8 5.3

4
8.2

A B

M3 x 0.5 7 Manual override


(A, B port)
2-ø1.8
(For monifold mounting)

2-ø3.2 equivalent Bracket (Light/surge voltage suppressor)


(For mounting) (18.5)

28 [35]
(18.5)
22.1

-+

13.5

12.6
15

(11.5)
0.5

R P R
10

14 ø1.2
(PE port)
M3 x 0.5
(P, R port)

L plug connector (L): M plug connector (M): M8 connector (WO):


3 3 3
SYJ3 45 20-L-M3 (-F) SYJ3 45 20-M-M3 (-F) SYJ3 45 20-WO-M3 (-F)
Approx. 300
(Lead wire length)

28 [35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1 [46.1]
(Lead wire length)
50.1 [52.3]

40.3 [42.5]

49.2
41.8
35.3

13.5 13.5 13.5


111.5 [115.9]

91.9 [96.3]

109.7
46.6

53.1

15
22.1 15
15
22.1
22.1

Refer to back page 11 for


dimentions with connector cable.

7
Series SYJ3000

2 Position Single [ ]: AC

G
Grommet (G), (H): SYJ3140- H -M5

M5 x 0.8 10
(A, B port)

5
10
2-ø3.2 32.2
(For mounting)
22 4

2.5
Manual override
B A

11
A
B
1
G: Approx. 300
H: Approx. 600 54.4 [56.6]
(Light/surge voltage suppressor) (Lead wire length)
41.5 [48.5]

-+

35.6
28.5
26.1

R2 P R1
13

10 10 10 M5 x 0.8
17.5 (P, R1, R2 port)
14
28

L plug connector (L): M plug connector (M): M8 connector (WO):


SYJ3140-L-M5 SYJ3140-M-M5 SYJ3140-WO-M5
Approx. 300
(Lead wire length)

41.5 [48.5]
26.1
46 M8 x 1
28.5
52.6 [59.6] Approx. 300
(Lead wire length)
64.3 [66.5]

54.5 [56.7]

63.4
56
49.5
R2

R2

R2
10 10

10 10

10 10
28

28

28
P

P
14

14

14
R1

R1

R1

5 5 5
28.5 28.5 28.5
35.6 35.6 35.6

Refer to back page 11 for


dimentions with connector cable.

8
Series SYJ3000

2 Position Double [ ]: AC

G
Grommet (G), (H): SYJ3240- -M5 H

M5 x 0.8 10
(A, B port)

5
10
2-ø3.2
(For mounting) 22

2.5
Manual override
B A

11
A
B
34.4
G: Approx. 300
H: Approx. 600 78.8 [83.2]
(Light/surge voltage suppressor) (Lead wire length)
41.5 [48.5]

-+
35.6
26.1

R2 P R1
13

10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)

28

L plug connector (L): M plug connector (M): M8 connector (WO):


SYJ3240-L-M5 SYJ3240-M-M5 SYJ3240-WO-M5
Approx. 300
(Lead wire length)

41.5 [48.5]
26.1
46 M8 x 1
28.5
52.6 [59.6] Approx. 300
(Lead wire length)
98.6[103]

79 [83.4]
R2

R2

R2
10 10

10 10

10 10

96.8
28

28

69

28

82
P

P
14

14

14
R1

R1

R1

5 5 5

Refer to back page 11 for


dimentions with connector cable.

9
Series SYJ3000

3 Position Closed Center/Exhaust Center/Pressure Center [ ]: AC


3
Grommet (G), (H): SYJ3 40- GH -M5 4
5

M5 x 0.8
10 (A, B port)

5
10
2-ø3.2 32 15.3
(For mounting)
22 3

2.5
Manual override
B A

11
A
B
37.5 [39.7]
G: Approx. 300
H: Approx. 600 91.7 [96.1]
(Lead wire length)
(Light/surge voltage suppressor)
41.5 [48.5]

-+
35.6
26.1

R2 P R1
13

10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)

28

L plug connector (L): M plug connector (M): M8 connector (WO):


3 3 3
SYJ3 45 40-L-M5 SYJ3 45 40-M-M5 SYJ3 45 40(R)-WO-M5
Approx. 300
(Lead wire length)

41.5 [48.5]
26.1
46 M8 x 1
28.5
52.6 [59.6] Approx. 300
(Lead wire length)
55.8
49.3
111.5 [115.9]
R2

R2

R2
91.9 [96.3]
10 10

10 10

10 10
28

28

28

109.7
P

P
14

14

14
R1

R1

R1
37.6 [39.8]

5 5 5
47.4 [49.6]

32.6

39.1
46.5

Refer to back page 11 for


dimentions with connector cable.

10
Series SYJ3000
Manifold Specifications
Manifold Standard

Manifold Specifications

Model Type 20 Type 31, S31 Type 32, S32 Type 41, S41 Type 46, S46

Manifold type Single base/B mount

Common SUP/Common EXH Common SUP


P (SUP), R (EXH)
Individual EXH
Valve stations 2 to 20 stations
A, B port Location Valve Base
Porting specifications Direction Top Side

M5 x 0.8 1/8 P: 1/8


P, R port R: M5 x 0.8
Port size
A, B port M3 x 0.5 M5 x 0.8, C4 (One-touch fitting for ø4)

Flow Characteristics

Flow characteristics
Port size Effective
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv (mm2)
Port Port [dm /(s·bar)]
3 [dm /(s·bar)]
3

Body ported
Type SS5YJ3-20 SYJ32 M5 x 0.8 M3 x 0.5 – – – – – – 0.9
for internal pilot
31
Type SS5YJ3- S31 SYJ33 M5 x 0.8 M3 x 0.5 – – – – – – 0.9
Type SS5YJ3-32-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 –
Type SS5YJ3-32-C4 C4 0.25 0.18 0.059 0.30 0.27 0.075 –
SYJ33 1/8
Type SS5YJ3-S32-M5 M5 x 0.8 0.25 0.26 0.060 0.29 0.15 0.062 –
Type SS5YJ3-S32-C4 C4 0.24 0.21 0.057 0.27 0.18 0.062 –
Base mounted Type SS5YJ3-41-M5 M5 x 0.8 0.32 0.25 0.081 0.33 0.19 0.079 –
for internal pilot Type SS5YJ3-41-C4 C4 0.32 0.28 0.079 0.35 0.24 0.084 –
SYJ34 1/8
Type SS5YJ3-S41-M5 M5 x 0.8 0.33 0.29 0.082 0.34 0.17 0.081 –
Type SS5YJ3-S41-C4 C4 0.32 0.27 0.079 0.34 0.24 0.084 –
Type SS5YJ3-46-M5 M5 x 0.8 0.20 0.25 0.048 0.10 0.12 0.024 –
Type SS5YJ3-46-C4 1/8 C4 0.21 0.27 0.050 0.21 0.13 0.047 –
SYJ34
Type SS5YJ3-S46-M5 M5 x 0.8 M5 x 0.8 0.20 0.25 0.048 0.19 0.16 0.024 –
Type SS5YJ3-S46-C4 C4 0.22 0.34 0.057 0.10 0.090 0.024 –
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model no.
Example:
 SS5YJ3-20-03 ··········· 1 set (Manifold base)  SS5YJ3-S41-03-C4 ··· 1 set (Manifold base)
∗ SYJ3120-5G-M3 ··· 2 sets (Valve) ∗ SYJ3140-5LZ ··········· 2 sets (Valve)
∗ SYJ3000-21-1A ···· 1 set (Blanking plate assembly) ∗ SYJ3000-21-2A ······· 1 set (Balnking plate assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

11
Series SYJ3000

Flat Ribbon Cable Manifold

 Multiple valve wiring is Flat Ribbon Cable Manifold Specifications


simplified through the use of
the flat cable connector. Model Type 21P Type 32P
 Clean appearance Manifold type Single base/B mount
In the case of a flat ribbon cable type, each P (SUP), R (EXH) Common SUP, Common EXH
valve is wired on the print board of manifold Valve stations 4 to 12 stations
base to allow the external wiring to be piped A, B port Location Valve Base
all together with 26 pins MIL connector. Porting specifications Direction Top Side
P, R port 1/8
Port size
A, B port M3 x 0.5 M5 x 0.8, C4 (One-touch fitting for ø4)
Applicable flat ribbon cable Socket: 26 pins MIL type with strain relief
connector (MIL-C-83503)
Internal wiring In common between +COM and –COM (Z type: +COM only)
Rated voltage 24, 12 VDC/100, 110 VAC
Note) The withstand voltage specification for the wiring unit section conforms to JIS C 0704, Grade 1 or
its equivalent.

Flow Characteristics
Type 21P
Flow characteristics
Port size Effective
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv (mm2)
Port Port [dm /(s·bar)]
3 [dm /(s·bar)]
3

Body ported
Type SS5YJ3-21P SYJ323 1/8 M3 x 0.5 – – – – – – 0.9
for internal pilot
Base mounted Type SS5YJ3-32P-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 –
for internal pilot Type SS5YJ3-32P-C4
SYJ333 1/8
C4 0.25 0.18 0.059 0.3 0.27 0.075 –
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold


 SS5YJ3-32P-07-C4 ····· 1 pc. (Manifold base) ∗ SYJ3000-21-4A ····· 1 pc. (Blanking plate assembly)
∗ SYJ3133-5LOU ········· 3 pcs. (Valve) ∗ SY3000-37-28A ····· 3 pcs. (Connector assembly)
∗ SYJ3233-5LOU ········· 3 pcs. (Valve) ∗ SY3000-37-29A ····· 3 pcs. (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

How to Order Valve How to Order Connector Assembly


Light/surge voltage suppressor
Rated voltage Z With light/surge voltage suppressor For 12, 24 VDC
5 24 VDC With light/surge voltage suppressor
U Single solenoid SY3000-37-28A
6 12 VDC (Non-polar type)
Double solenoid,
Note) Z: Positive common specifications only. SY3000-37-29A
3 position type
2
For DC SYJ3 1 33 5 LO U For 100 VAC
Single solenoid SY3000-37-46A
2
For AC SYJ3 1 33 1 LO Z Double solenoid,
SY3000-37-47A
3 position type
Type of actuation
1 2 position single A, B port size
2 2 position double Symbol Port size For 110 VAC (115 VAC)
3 3 position closed center Nil Base mounted Single solenoid SY3000-37-54A
4 3 position exhaust center M3 M3 x 0.5 Double solenoid,
5 3 position pressure center SY3000-37-55A
3 position type
Rated voltage
1 100 VAC
3 110 VAC (AC115V) Note) In the case of flat cable
type, “U” type is for DC
Manual override specifications and “Z” type
is for AC specifications. For
Nil Non-locking push type the opposite specification,
D Push-turn locking slotted type please contact SMC.
E Push-turn locking lever type

12
Series SYJ3000

Common SUP/Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20 (5 Port/Body ported) How to Order Applicable solenoid valve


SYJ320--M3
A, B port SS5YJ3–20– 05 SYJ323--M3
M3 x 0.5
Applicable blanking plate
Number of stations assembly
–+
–+
02 2 stations SYJ3000-21-1A
R
P
R
: :
R port P port 20 20 stations
M5 x 0.8 M5 x 0.8

Type 31 (4 Port/Base mounted) How to Order


Type 31 ( same side as the A,B port. ) SS5YJ3–
Type S31 Single solenoid coil is on
31– 05 –M3
Valve mounting direction Stations
Single solenoid coil is on 02 2 stations
–+ –+
Nil
opposite side as the A,B port.
–+ –+
–+

R –+
R : :
A
P R port –+

B
P
R port Single solenoid coil is on
B
M5 x 0.8 A, B port A S 20 20 stations
M5 x 0.8 same side as the A,B port.
A, B port M3 x 0.5 Applicable solenoid valve
P port P port
M3 x 0.5 SYJ330-
M5 x 0.8
M5 x 0.8 SYJ333-
Type 32 (4 Port/Base mounted) How to Order Applicable blanking plate
assembly
Type 32 Type S32 SS5YJ3– 32– 05 – M5 SYJ3000-21-2A

( Single solenoid coil is on


same side as the A,B port. )
Valve mounting direction Stations
P, R port
Single solenoid coil is on 02 2 stations
Nil
opposite side as the A,B port. thread type
: :
–+ –+
Single solenoid coil is on Nil Rc
–+ –+
–+ S same side as the A,B port. 20 20 stations
R
–+
–+ R F G
A, B port size
P
A R port B
P
R port
B N NPT
1/8 A
1/8
A, B port M5 M5 x 0.8 T NPTF
A, B port P port P port
M5 x 0.8, C4 1/8 C4 One-touch fitting for ø4
M5 x 0.8, C4 1/8
N3 One-touch fitting for ø5/32"

Type 41 (5 Port/Base mounted) How to Order Applicable solenoid valve


SYJ340-
Type 41 Type S41
SS5YJ3– 41– 05 – C4 SYJ343-

( Single
same side as the A,B port. )
solenoid coil is on
Valve mounting direction Stations
Applicable blanking plate
R port assembly
1/8 P port Single solenoid coil is on 02 2 stations SYJ3000-21-2A
Nil opposite side as the A,B port.
1/8 : :
Single solenoid coil is on
–+
S 20 20 stations
P, R port
–+
–+ –+
–+ same side as the A,B port.
–+

P
–+

R
R
A, B port size thread type
A
P port B
B

1/8
A
R port M5 M5 x 0.8 Nil Rc
A, B port 1/8 C4 One-touch fitting for ø4 F G
A, B port
M5 x 0.8, C4 M5 x 0.8, C4 N3 One-touch fitting for ø5/32" N NPT
T NPTF

Common SUP/Individual EXH Note) For more than10 stations, supply air to both sides of P port.

Type 46 (5 Port/Base mounted) How to Order Applicable solenoid valve


SYJ340-
Type 46 Type S46 SS5YJ3– 46– 05 – M5 SYJ343-
R1 R2 port
( Single
same side as the A,B port. )
solenoid coil is on
M5 x 0.8 Applicable blanking plate
Valve mounting direction Stations assembly
Single solenoid coil is on 02 2 stations SYJ3000-21-2A
Nil opposite side as the A,B port.
: :
–+
R1 R2 port –+
Single solenoid coil is on P port
–+ –+
S 20 20 stations
thread type
–+

P M5 x 0.8 –+
–+
same side as the A,B port.
P

A
A, B port B A, B port size Nil Rc
B A
A, B port P port M5 x 0.8, C4 M5 M5 x 0.8 F G
M5 x 0.8, C4 1/8
P port C4 One-touch fitting for ø4 N NPT
1/8 N3 One-touch fitting for ø5/32" T NPTF

13
Series SYJ3000

Flat Ribbon Cable Manifold

Common SUP/Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Applicable solenoid valve
Type 21P How to Order
Refer to page 12.
A, B port
M3 x 0.5 SS5YJ3–21P– 07 – Applicable connector
P, R port assembly
Stations thread type Refer to page 12.
04 4 stations Nil Rc Applicable blanking
: : 00F G plate assembly
P port 12 12 stations 00N NPT SYJ3000-21-3A
R port (With dust cap)
1/8 1/8 00T NPTF

Applicable solenoid valve


Type 32P How to Order
Refer to page 12.
A, B port SS5YJ3–32P– 07 – C4 Applicable connector
M5 x 0.8, C4 Stations P, R port assembly
04 4 stations
thread type Refer to page 12.
: : A, B port size Nil Rc
12 12 stations M5 M5 x 0.8
Applicable blanking
F G plate assembly
P port C4 One-touch fitting for ø4
R port N NPT SYJ3000-21-3A
1/8 N3 One-touch fitting for ø5/32" (With dust cap)
1/8 T NPTF

Mixed Installation of the SYJ300 and the SYJ3000 Valves on the Same Manifold
Series SYJ300 valves can be mounted on the
manifolds for Series SYJ3000.
q SS5YJ3-20, SS5YJ3-21P (SYJ300 3 port valve)
The 3 port valve can be used by simply sealing off
the unused “R” port with rubber plug SYJ3000-33-
1.
Applicable solenoid valves:
Series SYJ312, SYJ312M, SYJ322, SYJ322M (SYJ300 3 port valve)
w SS5YJ3-31, -S31, SS5YJ3-32, -S32,
SS5YJ3-46, -S46, SS5YJ3-32P
Plug (SYJ3000-33-1) Plug (SYJ3000-33-1)
The 3 port valve can be used without modifica-
tion. The A port of the valve will flow out of the B Seal the unused “R” port Seal the unused “R” port
port of the manifold. at the end the manifold. at the end the manifold.
Applicable solenoid valves:
Series SYJ314, SYJ314M, SYJ324, SYJ324M
e SS5YJ3-41, -S41
The 3 port valve can be used on the 4 port
manifold by simply sealing off the unused “R” port
with rubber plug SYJ3000-33-1. The A port of the –+
–+
valve will flow out of the B port of the manifold.
Applicable solenoid valves:
R
P

Series SYJ314, SYJ314M, SYJ324, SYJ324M


R

A
B

Caution
Mounting screw tightening torques
Type SS5YJ3-20 Type SS5YJ3-41
M1.7: 0.12 N·m
Use caution to the assembly orientation for A port of the 3 port valve flows out of the manifold B port.
solenoid valves, gasket, and optional parts.

14
Series SYJ3000

Combinations of Solenoid Valve, Manifold Gasket and Manifold Base


5 port body ported 4 port base mounted 5 port base mounted
(Type SYJ32 03 ) (Type SYJ33 03 ) (Type SYJ34 03 )
Round head combination screw
SY100-33-3
(M1.7 x 17, Matt nickel plated)
Applicable manifold base Applicable manifold base Applicable manifold base
Type SS5YJ3-20 Type SS5YJ3-31 Type SS5YJ3-41
Type SS5YJ3-S31 Manifold Type SS5YJ3-S41 Manifold
Type SS5YJ3-21P
Manifold base Type SS5YJ3-32 base Type SS5YJ3-46 base
Type SS5YJ3-S32 Type SS5YJ3-S46
Type SS5YJ3-32P
A Mark A Mark Protrusion for positioning
A
Manifold gasket A Manifold gasket Manifold gasket
SYJ3000-14-7 SYJ3000-14-6 SYJ3000-14-2

Note) Make sure to align the manifold gasket


with the groove of the valve body.

Combination of Blanking Plate Assembly and Manifold Base Difference between SYJ33 03 and SYJ34 03
Blanking plate assembly Blanking plate assembly SYJ330, 333 SYJ340, 343
SYJ3000-21-1A SYJ3000-21-2A (4 port) (5 port)
Round head combination screw

Blanking plate Steel ball is driven in.

Blanking plate

A Mark A Mark
Manifold Manifold
gasket gasket

Applicable manifold base Applicable manifold base


Type SS5YJ3-20 Manifold base Sub-plate
Type SS5YJ3-41
Type SS5YJ3-S41
Type SS5YJ3-46
Type SS5YJ3-S46
Type SS5YJ3-31 Manifold base
Configuration of surface is different.
Type SS5YJ3-S31
Type SS5YJ3-32
Type SS5YJ3-S32
Note) Manifold gasket “SYJ3000-14-2” can be
used with the following manifold bases.
Type SS5YJ3-31
Type -S31
Manifold base of
Type -32
Type -S32

Blanking plate assembly Blanking plate assembly


SYJ3000-21-4A SYJ3000-21-3A
Round head combination screw
Round head combination screw

Blanking plate
Blanking plate A Mark
A Mark

Manifold
Manifold
gasket
gasket

Dust cap Dust cap

Caution
Mounting screw tightening torques
M1.7: 0.12 N·m
Applicable manifold base Applicable manifold base Use caution to the assembly orientation for
Type SS5YJ3-32P Type SS5YJ3-21P solenoid valves, gasket, and optional parts.
Manifold base Manifold base

15
Series SYJ3000

Type 20 Manifold: Top Ported/SS5YJ3-20- Stations [ ]: AC

Approx. 300
(Lead wire length)
Grommet (G)

(Pitch)
P = 10.5 12.5
Manual override

4 5

3.7
15.8

1.5
91.7 [96.1]

78.8 [83.2]
7 10
R
R

A A A A A

14
19.5

11 10
30.7
31.5

29
52.9 [55.1]
53.7 [55.9]

B B B B B
R
R

2-ø3.5 M5 x 0.8
(For mounting) (P, R port)

M3 x 0.5
(A, B port)
L2 3.5
L1

(Station n) (Station 1)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+
42 [49]
26.6
13.5

L plug connector (L) M plug connector (M) M8 connector (WO)


Approx. 300
(Lead wire length)

42 [49]
26.6

M8 x 1
Approx. 300 53.1 [60.1]
(Lead wire length)
1.5

1.5
1.5
111.5 [115.9]

91.9 [96.3]

109.7
98.6[103]

79 [83.4]

94.9
96.8

82
53 [55.2]
62.8 [65]

54.5
61.9
0.8

0.8
0.8
0.8

29
46.5

Refer to back page 11 for


dimentions with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 35.5 46 56.5 67 77.5 88 98.5 109 119.5 130 140.5 151 161.5 172 182.5 193 203.5 214 224.5
L2 28.5 39 49.5 60 70.5 81 91.5 102 112.5 123 133.5 144 154.5 165 175.5 186 196.5 207 217.5

16
Series SYJ3000

Type 31 Manifold: Side Ported/SS5YJ3-31- Stations -M3 [ ]: AC

Grommet (G) Single solenoid coil


Type S31 Manifold: Side Ported is on same side as
Approx. 300
(Lead wire length)

the A,B port.


SS5YJ3-S31- Stations -M3
L1
3.5 L2

2-ø3.5
(For mounting) Manual override

M5 x 0.8

5.2
7.5
52.2 [54.4]

51.4 [53.6]

17.3
(P, R port)

3
91.7 [96.1]

78.8 [83.2]
78.8 [83.2]

13.5
A A A A A
B B B B B
91.7 [96.1]

R
R

R
29.2
R
30

29.2
25
12
25

51.4 [53.6]
52.2 [54.4]
30
3 13.5

B B B B B

P
P

P
P

A A A A A
17.3

7.5
5.2

Manual override 2-ø3.5


(Pitch) (For mounting)
(Pitch) P = 10.5 9
12.5 P = 10.5 L2 3.5
L1

(Station 1) (Station n) (Station n) (Station 1)


(Light/surge voltage suppressor) (Light/surge voltage suppressor)
43.5 [50.5]

-+ -+ -+ -+ -+ -+ -+
28.1

A A B B
15

15
12

12

B B A A
3

1 (Pitch) (Pitch) 1
13.5 P = 10.5 M3 x 0.5 M3 x 0.5 P = 10.5 14.5
(A, B port) (A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1 48
30.5
0.8

0.8

0.8
0.8
61.3 [63.5]

51.5 [53.7]

60.4

53
98.6[103]
111.5 [115.9]

79 [83.4]
91.9 [96.3]

96.8

82
109.7

94.9

Approx. 300 54.6 [61.6]


(Lead wire length)
(Lead wire length)

28
43.4 [47.3]
Approx. 300

Refer to back page 11 for


dimentions with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 35.5 46 56.5 67 77.5 88 98.5 109 119.5 130 140.5 151 161.5 172 182.5 193 203.5 214 224.5
L2 28.5 39 49.5 60 70.5 81 91.5 102 112.5 123 133.5 144 154.5 165 175.5 186 196.5 207 217.5

17
Series SYJ3000
Type 32 Manifold: Side Ported/SS5YJ3-32- Stations -M5, C4
N3  [ ]: AC

Approx. 300
(Lead wire length)
Grommet (G) L1 For C4
N3  (Built-in one-touch fitting)
Manual override
For M5 4 L2 10
2-ø4.5
(For mounting)

36.5
17
10 1/8
54.2 [56.4]

53.4 [55.6]
(P, R port)

78.8 [83.2]
91.7 [96.1]

31.5
3.2 31.2
R

(4.4)
12.5
B B B B B
32

17
1 16
P
P

A A A A A

7.5
15.3

(Station 1) (Station n)
L1
(Pitch) 4.5 L2
15.5 P = 10.5 (Light/surge voltage suppressor)
15.5
(Station 1) (Station n) -+ -+

(Light/surge voltage suppressor)


A A

20
48.5 [55.5]

15
5
B B
-+ -+

1.5 One-touch fitting


33.1

(Pitch)
A 16 P = 10.5 (A, B port)
20

A
15

B B
Applicable tubing O.D.: ø4, ø5/32"
1
5

(Pitch) M5 x 0.8
16.5 P = 10.5
(A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1 53
0.8

0.8
35.5
0.8

0.8
63.3 [65.5]

53.5 [55.7]
Approx. 300 111.5 [115.9]

62.4
98.6[103]

79 [83.4]
91.9 [96.3]

55
96.8
109.7

82
94.9
1
(Lead wire length)

Approx. 300 59.6 [66.6]


33.1 (Lead wire length)
48.4 [55.4]
Refer to back page 11 for
dimensions with connector cable.

Type S32 Manifold: Side Ported Single solenoid coil is on


same side as the A,B port. /SS5YJ3-S32- Stations -M5, C4
N3 
For C4  (Built-in one-touch fitting)
L1
For M5 L2 4 N3
Manual override
12.3

10
15.5
91.7 [96.1]

34.2 0.2

78.8 [83.2]

36.5
17
57.2 [59.4]

R
R

A A A A A
31.5

56.4 [58.6]
35

B B B B B
P
P

(4.4)
12.5

2-ø4.5 (Pitch) (Station n) (Station 1)


(For mounting) P = 10.5 15.5 L1
(Station n) (Station 1) L2 4.5
(Light/surge voltage suppressor)
15.5
(Light/surge voltage suppressor) -+ -+ -+ -+ -+

-+ -+ -+ -+ -+
B
20

B
15
5

A A
B B
20
5
15

1
M5 x 0.8 (Pitch) A A

P = 10.5 17.5 One-touch fitting


(Pitch) 1.5
(A, B port)
(A, B port) P = 10.5 18
Applicable tubing O.D.: ø4, ø5/32"

SS5YJ3-32, S32- Stations -M5


Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20
L1 41.5 52 62.5 73 83.5 94 104.5 115 125.5 136 146.5 157 167.5 178 188.5 199 209.5 220 230.5
L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5

SS5YJ3-32, S32- Stations -C4


Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20
L1 42.5 53 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5
L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5

18
Series SYJ3000
Type 41 Manifold: Side Ported/SS5YJ3-41- Stations -M5, C4
N3  [ ]: AC

Approx. 300
(Lead wire length)
Grommet (G) (Pitch)
For C4
N3  (Built-in one-touch fitting)
For M5 16 P = 10.5 1/8
10 (P port)
Manual override
1/8

36.4
61.7 [63.9] 10

60.9 [63.1]
10 (P port)

21.4
78.8 [83.2]
91.7 [96.1]

R
B B B B B
39.5

38.7

36.5
18

4.3

21.5
R

(4.4)
P
A A A A A
3
11.5

7.8

1/8 (Station 1) (Station n)


(R port) 2-ø4.5 4 L2 (Light/surge voltage suppressor)
(For mounting) L1
(Station 1) (Station n) -+ -+

(Light/surge voltage suppressor)


A A

20
48.5 [55.5]

15
B B

5
-+ -+

2 One-touch fitting
33.1

(Pitch)
A A
17 P = 10.5 (A, B port)
20
15
5

B B
Applicable tubing O.D.: ø4, ø5/32"
2 (Pitch) M5 x 0.8
17 P = 10.5
(A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1 53
0.8

35.5

0.8

0.8
0.8
70.8 [73]

61 [63.2]

69.9
111.5 [115.9]
98.6[103]

62.5
79 [83.4]
91.9 [96.3]

96.8
109.7

82
94.9
(Lead wire length)
Approx. 300

Approx. 300 59.6 [66.6]


(Lead wire length)
33.1
48.5 [55.5]
Refer to back page 11 for
dimentions with connector cable.

C4
Type S41 Manifold: Side Ported Single solenoid coil is on
same side as the A,B port. /SS5YJ3-S41- Stations -M5, N3 
(Pitch)
For M5 P = 10.5 16 For C4
N3  (Built-in one-touch fitting)
Manual override
32.2 2.2
33 14.3
91.7 [96.1]

78.8 [83.2]

1/8
10
55.2 [57.4]

54.4 [56.6]

(P port)
R

A A A A A
33.5
36.5
P

B B B B B
R

36.4
21.4

2-ø4.5
(4.4)

L2 4 (For mounting)
L1
(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+

-+ -+ -+ -+ -+

B B
20
15

B B
20

A A
15

A A
5

2 (Pitch) 2
M5 x 0.8 (Pitch) One-touch fitting
P = 10.5 15 P = 10.5 15
(A, B port) (A, B port)
Applicable tubing O.D.: ø4, ø5/32"

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5

19
Series SYJ3000
Type 46 Manifold: Side Ported/SS5YJ3-46- Stations -M5, C4
N3  [ ]: AC

Approx. 300
(Lead wire length)
Grommet (G)
(Pitch)
For C4
N3  (Built-in one-touch fitting)
For M5 14.5 P = 10.5 1/8
Manual override
10 (P port)

1/8

59.9 [62.1]
60.7 [62.9]
10

34.9
(P port)

78.8 [83.2]

18.9
91.7 [96.1]

B B B B B
38.5

37.7

35
3.3
P

19

(4.4)
A A A A A
10
8.8

2-ø4.5
4 L2 (For mounting) (Station 1) (Station n)
L1 (Light/surge voltage suppressor)

(Station 1) (Station n)
-+ -+
(Light/surge voltage suppressor)
48.5 [55.5]

A A

20
15
-+ -+
B B

5
33.1

A A 1.5(Pitch) One-touch fitting


20
15
5

B B 11.8 P = 10.5 (A, B port)


1.5 (Pitch) Applicable tubing O.D.: ø4, ø5/32"
11.8 P = 10.5 M5 x 0.8
(A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1 53
0.8

35.5

0.8

0.8
0.8
69.8 [72]

60 [62.2]

68.9
Approx. 300 111.5 [115.9]
98.6[103]

61.5
79 [83.4]
91.9 [96.3]

96.8
109.7

82
94.9
(Lead wire length)

Approx. 300 59.6 [66.6]


(Lead wire length)
33
48.5 [55.5]

Refer to back page 11 for


dimentions with connector cable.

C4
Type S46 Manifold: Side Ported Single solenoid coil is on
same side as the A,B port. /SS5YJ3-S46- Stations -M5, N3 
(Pitch)
For M5 P = 10.5 14.5 For C4
N3  (Built-in one-touch fitting)
Manual override
32.5 14.8

25 0.5
31.7 2.7
91.9 [96.3]

78.8 [83.2]

1/8
A A A A A
10
53.9 [56.1]

(P port)
54.7 [56.9]

25

35
P

B B B B B
34.9
18.9

2-ø4.5
(4.4)

L2 4 (For mounting)
L1
(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)

-+ -+ -+ -+ -+
(Light/surge voltage suppressor) -+ -+ -+ -+ -+

B B
20

B B
20

15
15

A A
5

A A
5

(Pitch) 1.5 One-touch fitting (Pitch) 1.5


M5 x 0.8 P = 10.5 15.7 P = 10.5 15.7
(A, B port)
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5

20
Series SYJ3000

Flat Ribbon Cable Manifold [ ]: AC

SS5YJ3-21P- Stations -00

L1
L2 4
Manual override
-+ -+ -+

M3 x 0.5 -+

(A, B port) 10
2 2

29.2 5.2
111.5 [115.9]

30 17.3

7.5
7 8.5

16 3

98.6[103]
A

P
P

31.5
61.3 [63.5]
62.1 [64.3]

17
45.5
B

65.3
R

2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+

Triangle mark
(Pitch) 1/8
P = 12.5 18.5 (P, R port)
(Station n) (Station 1)
(Light/surge voltage suppressor)
48.5 [55.5]

25.6
5.8
20

28.5

Applicable connector: 26 pins MIL type


With strain relief
(Conforming to MIL-C-83503)

SS5YJ3-32P- Stations -M5, C4


N3  For C4
N3  (Built-in one-touch fitting)
For M5 (Pitch)
P = 12.5 19.5
M5 x 0.8 1
(Pitch)
5

(A, B port) One-touch fitting


B B P = 12.5 19.5
15

A A
(A, B port) 1
Applicable tubing O.D.: ø4, ø5/32"
B B 5
15
20
A A

L1
L2 4
Manual override
-+ -+ -+

-+

10 10
3.2
32 15.3
111.5 [115.9]

7.5

(4.4)
12.4
31.2 1

98.6[103]
16

A A A A A A
P
P

31.5
63.3 [65.5]

17
64.1 [66.3]

36.4

B B B B B B
R
R

65.3

17

50.4
70.2

2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+

Triangle mark
(Pitch) 1/8
P = 12.5 18.5 (P, R port)
1/8
(Station n) (Station 1) (P, R port)
(Light/surge voltage suppressor)
Applicable connector: 26 pins MIL type
With strain relief
48.5 [55.5]

(Conforming to MIL-C-83503)
25.6
5.8
20

28.5 Station n Station 4 5 6 7 8 9 10 11 Station 12


L1 72.5 85 97.5 110 122.5 135 147.5 160 172.5
L2 64.5 77 89.5 102 114.5 127 139.5 152 164.5

21
22
Rubber Seal
5 Port Solenoid Valve

Series SYJ5000 For details about certified products conforming to


Specifications international standards, visit us at www.smcworld.com.

Fluid Air
2 position single 0.15 to 0.7
Operating pressure range
MPa 2 position double 0.1 to 0.7
3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing. Refer to back page 3.)
Response time (ms) Note 1) 2 position single, double 25 or less
(at 0.5 MPa) 3 position 40 or less
Max. operating frequency 2 position single, double 5
(Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Individual exhaust for the pilot valve, Common exhaust for the pilot and main valve
Body ported Lubrication Not required
Mounting orientation Unrestricted
Shock/Vibration resistance (m/s2) Note 2) 150/30
Enclosure Dust proof (∗ DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main valve and
armature in both energized and de-energized states every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle
directions of the main valve when pilot signal is ON and OFF. (Value in the initial state)

Solenoid Specifications

Base mounted Grommet (G), (H), L plug connector (L)


M plug connector: (M), DIN terminal (D)
Electrical entry M8 connector (W)
JIS Symbol G, H, L, M, W D
Body ported Base mounted (with sub-plate) DC 24, 12, 6, 5, 3 24, 12
2 position single 2 position single Coil rated voltage (V)
AC 50/60 Hz 100, 110, 200, 220
(A) (B) (B) (A) Allowable voltage fluctuation ±10% of rated voltage ∗
4 2 2 4 Standard 0.35 {With light: 0.4 (DIN terminal with light: 0.45)}
Power consumption (W) DC
With power saving circuit 0.1 (With light only)
5 1 3 100 V 0.78 (With light: 0.81) 0.78 (With light: 0.87)
3 1
(R1) (P) (R2) (R) (P) 110 V 0.86 (With light: 0.89) 0.86 (With light: 0.97)
[115 V] [0.94 (With light: 0.97)] [0.94 (With light: 1.07)]
2 position double 2 position double Apparent power VA ∗ AC
(B) (A) 200 V 1.18 (With light: 1.22) 1.15 (With light: 1.30)
(A) (B)
4 2 2 4 220 V 1.30 (With light: 1.34) 1.27 (With light: 1.46)
[230 V] [1.42 (With light: 1.46)] [1.39 (With light: 1.60)]
5 1 3
Surge voltage suppressor Diode (DIN terminal, Varistor when non-polar types)
3 1
(R1) (P) (R2) (R) (P) Indicator light LED (Neon light when AC with DIN terminal)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
3 position closed center 3 position closed center ∗ For 115 VDC and 230 VDC, the allowable voltage is –15% to +5% of rated voltage.
(A) (B) (B) (A) ∗ S, Z and T type (with power saving circuit) should be used within the following allowable voltage fluctuation range due to a
4 2 2 4 voltage drop caused by the internal circuit. S and Z type: 24 VDC: –7% to +10%, 12 VDC: –4% to +10%
T type: 24 VDC: –8% to +10%, 12 VDC: –6% to +10%
5 1 3
Built-in Speed Controller
(R1) (P) (R2) 3 1
(R) (P)
SYJ55 Throttle Valve Characteristics ( AB → R)
3 position exhaust center 3 position exhaust center  Built-in
exhaust flow controls enable simple cylinder
speed adjustments.
Effective area (mm2)

(A) (B) (B) (A)


4 2 2 4  When mounted on the manifold, the common exhaust
discharges the pilot and main valve exhaust through a 2
5 1 3 3 1
common EXH port to enable simple exhausting.
(R1) (P) (R2) (R) (P) (B)(A)
JIS Symbol 2 4
3 position pressure center 3 position pressure center
1
(A) (B) (B) (A)
4 2 2 4
3 1 (Single)
(R)(P) 2 0(Fully 1
3 4 5 6 7 (Fully
5 1 3
3 1
closed) open)
(R1) (P) (R2)
(R) (P) How to order valve with built-in speed controller  When using SYJ553 model the speed controller
must be opend more than 1 complete rotation from
SYJ5 5 – – fully closed in order to function proerly.
 Adjust the speed controller with a torque of 0.3 N•m
Made to Order Type of Port size or less.
(For details, refer to pages 79 through to 80.) actuation
Manual override Plate fixing screw
Body Option
Rated voltage Light/surge voltage suppressor
Lead wire
Note) Do not loosen plate fixing screw.
23
Series SYJ5000

Flow Characteristics/Weight
Port size Flow characteristics Note 1) Weight (g) Note 2, 3)
Valve model Type of actuation 1, 5, 3 4, 2 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) L/M plug DIN M8
(P, EA, EB) (A, B) C [dm3/(s·bar)] Grommet
b Cv C [dm3/(s·bar)] b Cv connector terminal connector
Single 46 47 68 51
2 position 0.47 0.41 0.13 0.47 0.41 0.13
Double 64 66 108 74
SYJ520--M5 Closed center M5 x 0.8 M5 x 0.8 0.49 0.44 0.13 0.44 0.40 0.12
3 position Exhaust center 0.46 0.37 0.12 0.47 [0.39] 0.43 [0.35] 0.13 [0.10] 75 77 119 85
Pressure center 0.49 [0.39] 0.51 [0.38] 0.14 [0.10] 0.45 0.42 0.12
Single 53 54 75 58
Body ported

2 position 0.69 0.39 0.18 0.44 0.39 0.12


Double C4 71 73 115 81
SYJ520--C4 Closed center M5 x 0.8 (One-touch 0.69 0.40 0.19 0.43 0.40 0.12
3 position Exhaust center fitting for ø4) 0.56 0.40 0.15 0.41 [0.41] 0.37 [0.37] 0.10 [0.11] 82 84 126 72
Pressure center 0.57 [0.41] 0.4 [0.37] 0.15 [0.10] 0.41 0.37 0.10
Single 53 54 75 58
2 position 0.70 0.36 0.19 0.47 0.40 0.12
Double C6 71 73 115 81
SYJ520--C6 Closed center M5 x 0.8 (One-touch 0.72 0.37 0.19 0.44 0.34 0.12
3 position Exhaust center fitting for ø6) 0.67 0.54 0.19 0.41 [0.41] 0.38 [0.38] 0.11 [0.11] 82 84 126 92
Pressure center 0.82 [0.44] 0.41 [0.39] 0.23 [0.12] 0.41 0.36 0.11
Base mounted

Single 80 (49) 81 (47) 102 (68) 51


2 position 0.79 0.21 0.19 0.83 0.32 0.21
Double 98 (64) 100 (66) 142 (108) 74
SYJ540--01 Closed center 1/8 1/8 0.80 0.28 0.18 0.86 0.34 0.20
3 position Exhaust center 0.71 0.26 0.18 1.1 [0.60] 0.24 [0.44] 0.26 [0.18] 109 (75) 111 (77) 153 (119) 85
Pressure center 0.99 [0.47] 0.29 [0.38] 0.24 [0.12] 0.72 0.38 0.18
Note 1) [ ]: denotes the normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate.
Note 3) For DC voltages. For AC voltages add 3 g to the weight of the single solenoid and 6 g to the weight of the double solenoid and 3 position types.

Cylinder Speed Chart


Use as a guide for selection.
Please confirm the actual conditions with SMC
Body Ported Sizing Program.
Bore size
Series CJ2 Series CM2
Average speed Pressure 0.5 MPa Pressure 0.5 MPa
Series
(mm/s) Load rate: 50% Load rate: 50%
Stroke 60 mm Stroke 300 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40
800
700 Perpendicular, upward actuation
600
Horizontal actuation
500
SYJ5120-M5 400
300
200
100
0

Base Mounted
Bore size
Series CJ2 Series CM2 Series MB/CA2
Average speed Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series Load rate: 50%
(mm/s) Load rate: 50% Load rate: 50%
Stroke 60 mm Stroke 300 mm Stroke 500 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
800
700 Perpendicular, upward actuation
600
500 Horizontal actuation
SYJ5140-01 400
300
200
100
0
∗ Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
∗ Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
∗ Load factor: ( (Load weight x 9.8) /Theoretical force) x 100%

Conditions
Body ported Series CJ2 Series CM2 Series MB/CA2 Base mounted Series CJ2 Series CM2 Series MB/CA2
Tubing bore x Length ø4 x 1 m ø6 x 1 m ø8 x 1 m Tubing bore x Length ø4 x 1 m ø6 x 1 m
SYJ5120-M5 Speed controller AS1301F-04 AS3301F-06 AS3301F-08 SYJ5140-01 Speed controller AS2301F-04 AS3001F-06
Silencer AN120-M5 AN110-01 Silencer AN101-01 AN101-01

24
Series SYJ5000

How to Order
Light/surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Type of actuation Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
1 2 position single solenoid S With surge voltage suppresor S With surge voltage suppressor (Non-polar type)
2 2 position double solenoid Z With light/surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type)
3 3 position closed center R With surge voltage suppressor (Non-polar type) ∗ DOZ is not available.
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
5 3 position pressure center ∗ For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit. Bracket
∗ For type “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the "Z" type. Nil: Without bracket
F: With bracket
Rated voltage
DC AC (50/60 Hz)
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC [115 VAC] M5 M5 x 0.8
S 5 VDC 4 220 VAC [230 VAC] C4 One-touch fitting for ø4
R 3 VDC ∗ For type W, C6 One-touch fitting for ø6
∗ DC specifications of type DC voltage is N3 One-touch fitting for ø5/32"
D and DO is only available only available. N7 One-touch fitting for ø1/4"
with 12 and 24 VDC. Note) The mounting bracket is
(For manifold type 20) supplied unattached.

Body ported SYJ5 1 2 0 5 L M5

Base mounted SYJ5 2 4 0 5 L


Thread type
Nil Rc
Body option Coil specifications Manual override F G
Nil Standard N NPT
0: Pilot valve individual Nil: Non-locking push
exhaust for the pilot valve With power saving circuit type T NPTF
T
<24 V, 12 VDC only>
∗ Power saving circuit is
For sub-plate, manifold type
not available in the
Port size
40, 41, 42, 43
R port P, E port
case of D, DO or W Nil: Without sub-plate
type.
3: Common exhaust type
for main and pilot valve
D: Push-turn locking
slotted type

R port P, E port
(With gasket and screws)

01: 1/8 With sub-plate


Electrical entry
24, 12, 6, 5, 3 VDC 24,12 VDC 24, 12,
100,110, 200, 220 VAC 100,110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector DIN terminal M8 connector E: Push-turn locking
lever type
G: Lead wire L: With lead wire M: With lead wire MN: Without D: With connector WO: Without
length 300 mm (Length 300 mm) (Length 300 mm) lead wire connector
cable
–+
–+

–+ –+

H: Lead wire LN: Without LO: Without MO: Without DO: Without W: With
length 600 mm lead wire connector connector connector connector
cable Note 1)

–+ –+ Note 1) Enter the cable length symbols in .


Please be sure to fill in the blank
referring to back page 10.
∗ LN, MN type: with 2 sockets.
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is also available. For
details, refer to page 80.
∗ For connector cable of M8 connector, refer to back page 10.

25
Series SYJ5000

Construction

2 position single (A) (B)


4 2
2 position double (A) (B)
4 2

5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)

e qy t rw w q (A) t(B) r
(A) (B)
4 2 4 2

i
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
i

3 position closed center/exhaust center/pressure center


3 position closed center
(A) (B)
4 2

5 1 3
t q rw
(R1) (P) (R2)
(A) (B)
3 position exhaust center
(A) (B) 4 2
4 2

5 1 3
(R1) (P) (R2)

3 position pressure center


(A) (B)
4 2 i
5 1 3 5 1 3
(R1) (P) (R2)
(R1) (P) (R2)
(This figure shows a closed center type.)

Component Parts Replacement Parts


No. Description Material Note No. Description No. Note
1 Body Aluminum die-casted White 7 Sub-plate SYJ5000-22-1 Aluminum die-casted
2 Piston plate Resin White 8 Pilot valve V111(T)-
3 End cover Resin White — Bracket assembly SYJ5000-13-3A
4 Piston Resin —
5 Spool valve assembly Aluminum, H-NBR —
6 Spool spring Stainless steel —

26
Series SYJ5000

How to Order Connector Assembly


How to Order Pilot Valve Assembly for L/M Plug Connector

V111 5 G For DC : SY100-30-4A-


Light/surge voltage suppressor For 100 VAC : SY100-30-1A-
Coil specifications Nil Without light/surge voltage suppressor
S With surge voltage suppresor
Nil Standard
Z With light/surge voltage suppressor
For 200 VAC : SY100-30-2A-
With power saving circuit
T R With surge voltage suppressor (Non-polar type)
(24, 12 VDC only)
For other
∗ Power saving circuit is
U With light/surge voltage suppressor (Non-polar type) voltages of AC : SY100-30-3A-
not available in the ∗ For AC voltage valves there
case of W type. is no “S” option. It is already
built-in to the rectifier circuit. Without lead wire : SY100-30-A
∗ For type “R” and “U”, DC (with connector and 2 of sockets only)
Rated voltage voltage is only available.
∗ Power saving circuit is only Lead wire length
5 24 VDC available in the "Z" type. Nil 300 mm
6 12 VDC 6 600 mm
V 6 VDC
Electrical entry
10 1000 mm
S 5 VDC G Grommet, 300 mm lead wire
H Grommet, 600 mm lead wire 15 1500 mm
R 3 VDC 20 2000 mm
L With lead wire
1 100 VAC 50/60 Hz L plug
LN Without lead wire 25 2500 mm
2 200 VAC 50/60 Hz connector
LO Without connector 30 3000 mm
110 VAC 50/60 Hz M With lead wire 50 5000 mm
3 M plug
[115 VAC 50/60 Hz] MN Without lead wire
connector
220 VAC 50/60 Hz MO Without connector
4 [230 VAC 50/60 Hz] WO Without connector cable
M8
∗ For type W, DC W connector With connector cable Note 1)
voltage is only ∗ For connector cable of M8 connector,
available. refer to back page 10.
Note 1) Enter the cable length symbols
in . Please be sure to fill in the How to Order M8 Connector Cable
blank referring to back page 10.

V100-49-1-

V115 5 D 1
Cable length
300 mm
Light/surge voltage suppressor 2 500 mm
Rated voltage
Nil Without light/surge voltage suppressor 3 1000 mm
5 24 VDC
S With surge voltage suppressor (Non-polar type) 4 2000 mm
6 12 VDC
Z With light/surge voltage suppressor (Non-polar type) 7 5000 mm
1 100 VAC 50/60 Hz
∗ DOZ is not available.
2 200 VAC 50/60 Hz ∗ For AC voltage valves there is no “S” option.
110 VAC 50/60 Hz It is already built-in to the rectifier circuit.
3
[115 VAC 50/60 Hz]
220 VAC 50/60 Hz Electrical entry
4 D With connector
[230 VAC 50/60 Hz] DIN
∗ DC specifications of DO terminal Without connector
type D and DO is Note) Do not replace V111 (G, H, L, M,
only available with W) to V115 (DIN terminal) and
12 and 24 VDC. vice versa when replacing pilot
∗ Power saving circuit valve assembly only.
is not available in
the case of D or DO
type.

27
Series SYJ5000

2 Position Single [ ]: AC

Grommet (G), (H): SYJ5120- GH -M5 With bracket


SYJ5120- H -M5-F
G

37
G: Approx. 300
63.1 [65.3] H: Approx. 600 2-ø3.5 30 3.5
(Lead wire length) (For mounting)
41
19.5

18
25
-+
11

19.7
5

A B

35.1 [42.1]
M5 x 0.8 10 Manual override
(A, B port) 19 2-ø2.6
(For monifold mounting)

63.1 [65.3]
2-M3 x 0.5 (Light/surge voltage suppressor)
(Mounting screw)

-+
18

23
20

2.3
(Bracket)
28.1 [35.1]
12.7
2.5

10.6 11 2-ø2.6
3.5 4
Built-in one-touch fitting:
(For mounting)
SYJ5120- GH - C4, N3
C6, N7 (-F)
19.5

3.5
A B
R1 P
16

15

R2 10.6
(3.2) One-touch fitting
M5 x 0.8 21 ø1.4 (A, B port)
(P, R1, R2 port) (PE port) Applicable tubing O.D. : ø4, ø5/32"
: ø6, ø1/4"
32.3

(2.3)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ5120-L-M5(-F) SYJ5120-M-M5(-F) SYJ5120-D-M5(-F) SYJ5120-WO-M5(-F)
Approx. 300
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Max. 10

28.1 [35.1] 60.9


53.4
12.7
42.1
M8 x 1 32.6
Approx. 300 39.2 [46.2] 15.1
(Lead wire length) Pg7
73 [75.2]

63.2 [65.4]

82.1

83

72.1
58.2

64.7

3 3 3 3
42.2
19.5

19.5

19.5

19.5
11
11
11

11

20 2-ø2.6 20 2-ø2.6 20 2-ø2.6


(2.3)

(2.3)
(2.3)

20 2-ø2.6
(2.3)

23 (For mounting) (For mounting) 23 (For mounting)


23 23 (For mounting)
27

Refer to back page 11 for dimentions


with connector cable.

28
Series SYJ5000

2 Position Double [ ]: AC

G
Grommet (G), (H): SYJ5220- H -M5 Built-in one-touch fitting:
SYJ5220- GH - C4, N3
C6, N7

G: Approx. 300
87.2 [91.6] H : Approx. 600
43 (Lead wire length)

3.5
11
5

A B A B

10 Manual override 10.6


M5 x 0.8 19 2-ø2.6
(A, B port) (For monifold mounting)

(3.2)
One-touch fitting
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D. : ø4, ø5/32"
: ø6, ø1/4"

32.3
-+
23
20
3

28.1 [35.1]

11 2-ø2.6
12.7

(For mounting)

R1 P
15

R2
M5 x 0.8 21 ø1.4
(P, R1, R2 port) (PE port)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ5220-L-M5 SYJ5220-M-M5 SYJ5220-D-M5 SYJ5220-WO-M5
Approx. 300
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Max. 10

28.1 [35.1] 60.9


12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2 [46.2]
(Lead wire length) Pg7

20 20 20 20
107 [111.4]

3
87.4 [91.8]

3 3 3
105.2
125.2

90.4
77.4

45.4

127

11
11

11
11

23
2-ø2.6 2-ø2.6 2-ø2.6
(For mounting) (For mounting) (For mounting)

23
23
23
27
2-ø2.6
(For mounting)

Refer to back page 11 for dimentions


with connector cable.

29
Series SYJ5000

3 Position Closed Center/Exhaust Center/Pressure Center [ ]: AC


3
Grommet (G), (H): SYJ5 45 20- GH -M5 Built-in one-touch fitting:
3
SYJ5 45 20- GH - C4, N3
C6, N7

G: Approx. 300
103.2 [107.6] H: Approx. 600
44.2 [46.4] (Lead wire length)
36.9 22.1 44.2 [46.4]

3.5
11
5

A B A B

M5 x 0.8 10 Manual override 10.6


(A, B port) 19
2-ø2.6
(For monifold mounting)

(3.2)
One-touch fitting
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D. : ø4, ø5/32"
: ø6, ø1/4"

32.3
-+
23
20
3

2-ø2.6 28.1 [35.1]


12.7
11
(For mounting)

R1 P
15

R2
M5 x 0.8 21 ø1.4
(P, R1, R2 port) (PE port)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SYJ5 4 20-L-M5 SYJ5 4 20-M-M5 SYJ5 4 20-D-M5 SYJ5 4 20-WO-M5
5 5 5 5
(Lead wire length)
Approx. 300

Applicable cable O.D.


ø3.5 to ø7
Max. 10

28.1 [35.1] 60.9


12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2 [46.2]
(Lead wire length)
Pg7
54.1 [56.3]

44.3 [46.5]

64.1
63.2

53.2
45.8
39.3

20 20 20 20
23.3

3 3 3 3
103.4 [107.8]
123 [127.4]

11
11

11
141.2

121.2
143
11
38.1

23 2-ø2.6 23 2-ø2.6 23 23
54.1

60.6

(For mounting) (For mounting) 2-ø2.6 2-ø2.6


(For mounting) (For mounting)

27

Refer to back page 11 for dimentions


with connector cable.

30
Series SYJ5000

2 Position Single [ ]: AC

G
Grommet (G), (H): SYJ5140- H -01 Built-in speed controller:
SYJ5150- H -01
G

Max. 13.5
1/8 19.4 10.3
17 11.5
(A, B port)

8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24 With interface regulator
B

R P

G: Approx. 300 41 0.5


H: Approx. 600 63.6 [65.8]
(Lead wire length)
107.5 [109.7]

(Light/surge voltage suppressor)

69.6 [76.6]
50.1 [57.1]

-+

54.2
45
34.7

8.5

31.5
21.5

15 17 17 43.9
24 1/8 45.5
(P, R port)
32

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ5140-L-01 SYJ5140-M-01 SYJ5140-D-01 SYJ5140-WO-01

Applicable cable O.D.


(Lead wire length)
Approx. 300

ø3.5 to ø7
82.9
Max. 10

50.1 [57.1] 75.4


34.7 64.1
49 54.6 M8 x 1
37.1
61.2 [68.2] Approx. 300
(Lead wire length) Pg7
6 6 6 6
73.5 [75.7]

63.7 [65.9]

83.5

82.6

65.2
72.6
58.7
45.5

45.5

45.5

45.5
17 17

17 17

17 17

17 17
42.7
0.5

0.5
0.5

6 6 6 6
0.5

8.5 8.5 8.5 8.5


21.5 21.5 21.5 21.5

Refer to back page 11 for dimentions


with connector cable.

31
Series SYJ5000

2 Position Double [ ]: AC

Grommet (G), (H): SYJ5240-GH -01 Built-in speed controller:


SYJ5250- GH -01

1/8 17 11.5
(A, B port)

Max. 13.5
8.5
19.4 10.3

2-ø4.3
(For mounting)
37.5 4
Manual override
B A

24
B

R P

41.5 1.5
G: Approx. 300 23.6 [25.8]
H: Approx. 600 87.2 [91.6] With interface regulator
(Lead wire length)

107.5 [109.7]
(Light/surge voltage suppressor)

69.6 [76.6]
50.1 [57.1]

-+

54.2
45
34.7

31.5
8.5
21.5

15 17 17 43.9
24 1/8 45.5
(P, R port)
32

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ5240-L-01 SYJ5240-M-01 SYJ5240-D-01 SYJ5240-WO-01
Applicable cable O.D.
Approx. 300
(Lead wire length)

ø3.5 to ø7
82.9
Max. 10

50.1 [57.1] 75.4


34.7 64.1
49 54.6
M8 x 1
61.2 [68.2] Approx. 300 37.1
(Lead wire length) Pg7
6 6 6 6
107 [111.4]

87.4 [91.8]

65.2
58.7
45.5

45.5

45.5

45.5
125.2

105.2
17 17

17 17

17 17

17 17
42.7
127

2.7
18.7

6 6 6 6
25.2
32.6
42.6
43.5

8.5 8.5 8.5 8.5


21.5 21.5 21.5 21.5
23.7 [25.9]
33.5 [35.7]

Refer to back page 11 for dimentions


with connector cable.

32
Series SYJ5000

3 Position Closed Center/Exhaust Center/Pressure Center [ ]: AC


3
Grommet (G), (H): SYJ5 45 40-GH -01 Built-in
3
speed controller:
SYJ5 45 50- GH -01

1/8 17 11.5

Max. 13.5
(A, B port)
19.4 10.3

8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A

24
B

R P

42.1 16.9
G: Approx. 300
39 [41.2] With interface regulator
H: Approx. 600 103.2 [107.6]
(Lead wire length)

108.1 [110.3]
(Light/surge voltage suppressor)

69.6 [76.6]
50.1 [57.1]

-+

54.2
45
34.7

31.5
21.5

15 17 17 43.9
8.5

1/8
24 45.5
(P, R port)
32

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SYJ5 4 40-L-01 SYJ5 4 40-M-01 SYJ5 4 40-D-01 SYJ5 4 40-WO-01
5 5 5 5
Applicable cable O.D.
(Lead wire length)

ø3.5 to ø7
Approx. 300

82.9
Max. 10

50.1 [57.1] 75.4


64.1
34.7
49 54.6 M8 x 1
61.2 [68.2] Approx. 300 37.1
(Lead wire length) Pg7
6 6 6 6
65.8
103.4 [107.8]
59.3
123 [127.4]
45.5

45.5

45.5

45.5
43.3
17 17

17 17

17 17

17 17
141.2

121.2
143

18.1
48.9 [51.1]

6 6 6 6
34.1

40.6

8.5 8.5 8.5 8.5


48
58.9

58

21.5 21.5 21.5 21.5


39.1 [41.3]

Refer to back page 11 for dimentions


with connector cable.

33
Series SYJ5000
Manifold Specifications
Manifold Standard

Manifold Specifications

Model Type 20 Type 40 Type 41 Type 42 Type 43


Manifold type Single base/B mount

P (SUP), R (EXH) Common SUP, Common EXH

Valve stations 2 to 20 stations


A, B port Location Valve Base Base
Porting specifications Direction Top Bottom Side
P, R port 1/8 1/4 1/8
Port size M5 x 0.8, 1/8, C6
A, B port C4 (One-touch fitting for ø4) M5 x 0.8 (One-touch C4 (One-touch
C6 (One-touch fitting for ø6) fitting for ø6) fitting for ø4)

Flow Characteristics

Flow characteristics
Port size
1 → ω4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
Port Port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
for internal pilot
Type SS5YJ5-20 SYJ52 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
Type SS5YJ5-40 1/8 M5 x 0.8 0.55 0.35 0.15 0.64 0.26 0.16
Type SS5YJ5-41 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
Base mounted
for internal pilot
Type SS5YJ5-42-01 SYJ54 1/4 1/8 0.74 0.22 0.18 0.82 0.31 0.21
Type SS5YJ5-42-C6 1/4 C6 0.71 0.24 0.17 0.8 0.29 0.20
Type SS5YJ5-43 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model no.
Example: SS5YJ5-20-03 ······················ 1 pc. (Manifold base)
∗ SYJ5120-5G-M5 ················· 2 pcs. (Valve)
∗ SYJ5000-21-4A ··················· 1 pc. (Blanking plate assembly)

SS5YJ5-43-03-C4 ·············· 1 pc. (Manifold base)


∗ SYJ5140-5LZ ······················· 1 pc. (Valve)
∗ SYJ5240-5LZ ······················· 1 pc. (Valve)
∗ SYJ5000-21-4A ··················· 1 pc. (Blanking plate assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

34
Series SYJ5000

Flat Ribbon Cable Manifold


 Multiple valve wiring is Flat Ribbon Cable Manifold Specifications
simplified through the use of
the flat cable connector. Model Type 20 Type 41P Type 43P
Manifold type Single base/B mount

P (SUP), R (EXH) Common SUP, Common EXH
Clean appearance
Valve stations 3 to 12 stations
In the case of a flat ribbon cable type, each
A, B port Location Valve Base
valve is wired on the print board of
manifold base to allow the external wiring Porting specifications Direction Top Side
to be piped all together with 26 pins MIL P, R port 1/8 1/8
connector. Port size M5 x 0.8, C4
A, B port C4 (One-touch fitting for ø4) M5 x 0.8
C6 (One-touch fitting for ø6) (One-touch fitting for ø4)
Applicable flat ribbon cable Socket: 26 pins MIL type with strain relief
connector (MIL-C-83503)
Internal wiring In common between +COM and –COM (Z type: +COM only).
Rated voltage 24, 12 VDC/100, 110 VAC
Note) The withstand voltage specification for the wiring unit section conforms to JIS C 0704, Grade 1 or its
equivalent.

Flow Characteristics
Flow characteristics
Port size
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
Port Port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
for internal pilot
Type SS5YJ5-20P SYJ523 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
Base mounted Type SS5YJ5-41P 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
SYJ543
for internal pilot Type SS5YJ5-43P 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model no.
Example: SS5YJ5-41P-07-C4 ··········· 1 pc. (Manifold base)
∗ SYJ5143-5LOU ··················· 3 pcs. (Valve)
∗ SYJ5243-5LOU ··················· 3 pcs. (Valve)
∗ SYJ5000-21-3A ··················· 1 pc. (Blanking plate assembly)
∗ SY3000-37-28A ··················· 3 pcs. (Connector assembly)
∗ SY3000-37-29A ··················· 3 pcs. (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.


How to Order Valve How to Order Connector Assembly
Rated voltage Light/surge voltage suppressor For 12, 24 VDC
Z With light/surge voltage suppressor Single solenoid SY3000-37-28A
5 24 VDC
U With light/surge voltage suppressor(Non-polar type) Double solenoid, 3 position type SY3000-37-29A
6 12 VDC
Note) Z: Positive common specifications only. Single solenoid, individual SUP, EXH spacer SY3000-37-3A
Double solenoid, 3 position individual SUP/EXH spacer SY3000-37-4A
2
For DC SYJ5 1 43 5 LO Z Interface regulator for single solenoid SY3000-37-3A
Double solenoid, 3 position interface regulator SY3000-37-6A
3 port adaptor plate SY3000-37-3A
2
For AC SYJ5 1 43 1 LOZ For 100 VAC
Single solenoid SY3000-37-46A
Type of actuation Double solenoid, 3 position type SY3000-37-47A
1 2 position single Single solenoid, individual SUP, EXH spacer SY3000-37-32A
2 2 position double A, B port size Double solenoid, 3 position individual SUP/EXH spacer SY3000-37-33A
3 3 position closed center Symbol Port size Interface regulator for single solenoid SY3000-37-15A
4 3 position exhaust center Nil Base mounted Double solenoid, 3 position interface regulator SY3000-37-34A
5 3 position pressure center Rated voltage M5 M5 x 0.8 3 port adaptor plate SY3000-37-32A
C4 One-touch fitting for ø4 For 100 VAC (115 VAC)
1 100 VAC
C6 One-touch fitting for ø6 Single solenoid SY3000-37-54A
3 110 VAC (115 VAC)
N3 One-touch fitting for ø5/32" Double solenoid, 3 position type SY3000-37-55A
Manual override N7 One-touch fitting for ø1/4" Single solenoid, individual SUP, EXH spacer SY3000-37-35A
Nil Non-locking push type Note) In the case of flat cable type, “U” and “Z” Double solenoid, 3 position individual SUP/EXH spacer SY3000-37-36A
D Push-turn locking slotted type types are for DC specifications and “Z” Interface regulator for single solenoid SY3000-37-19A
type is for AC specifications. “Z” type for
E Push-turn locking lever type Double solenoid, 3 position interface regulator SY3000-37-37A
DC is positive common specification
only. For the ohter combination, please 3 port adaptor plate SY3000-37-35A
contact SMC.

35
Series SYJ5000

Common SUP/Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20 (5 Port/Body ported) How to Order Applicable solenoid valve


M5
SYJ520-- C4
A, B port SS5YJ5–20– 05 – C6
M5
M5 x 0.8 SYJ523-- C4
C6
-+ Number of stations P, R port Applicable blanking
-+
P port thread type
R
02 2 stations plate assembly
1/8 Nil Rc
R
P
: : SYJ5000-21-4A
20 20 stations
00F G Applicable individual
R port 00N NPT EXH spacer assembly
1/8 00T NPTF SYJ5000-17-1A

Type 40 (5 Port/Base mounted) How to Order Applicable solenoid valve


SYJ540-
SS5YJ5– 40– 05 – M5 SYJ543-
P port SYJ550-
1/8 SYJ553-
Stations P, R port
02 2 stations thread type Applicable blanking
: Nil Rc plate assembly
:
F G SYJ5000-21-4A
R port 20 20 stations
N NPT Applicable individual
A, B port 1/8 T NPTF EXH spacer assembly
M5 x 0.8 A, B port size
SYJ5000-17-1A
M5 M5 x 0.8
Applicable individual
SUP spacer assembly
ARBYJ5000-00-P

Type 41 (5 Port/Base mounted) How to Order


SS5YJ5– 41– 05 –M5
Stations
-+ 02 2 stations P, R port
-+

R port : : thread type


R

1/8 Nil Rc
P

20 20 stations
A, B port
F G
M5 x 0.8 P port A, B port size N NPT
1/8 M5 M5 x 0.8 T NPTF
Applicable solenoid valve
Type 42 (5 Port/Base mounted) How to Order SYJ540-
SS5YJ5– 42– 05 – C6 SYJ543-
SYJ550-
SYJ553-
Stations
-+ 02 2 stations Applicable blanking
-+
plate assembly
B
R port : :
SYJ5000-21-4A
R

20 20 stations
P

1/4 Applicable individual


A Thread type
A, B port B A, B port size Nil Rc EXH spacer assembly
P port
1/8, C6 01 1/8 F G SYJ5000-17-1A
1/4
C6 One-touch fitting for ø6 N NPT Applicable individual
N7 One-touch fitting for ø1/4" T NPTF SUP spacer assembly
SYJ5000-16-2A
Type 43 (5 Port/Base mounted) How to Order Applicable individual
SS5YJ5– 43– 05 – C4 SUP spacer assembly
ARBYJ5000-00-P

Stations
-+
-+
02 2 stations
R R port : : P, R port
P thread type
A 1/8
A, B port 20 20 stations
B Nil Rc
C4 P port
A, B port size F G
1/8
C4 One-touch fitting for ø4 N NPT
N3 One-touch fitting for ø5/32" T NPTF

36
Series SYJ5000

Flat Ribbon Cable Manifold


Common SUP/Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20 (5 Port/Body ported) How to Order Applicable solenoid valve


Refer to page 35.
A, B port
A
SS5YJ5–20P– 05 –
B
A

A
Applicable blanking
plate assembly
B

A
P port P, R port
Number of stations
B

1/8 thread type SYJ5000-21-3A


03 3 stations
Nil Rc
: : Applicable connector
00F G
12 12 stations 00N NPT assembly
R port
1/8 00T NPTF Refer to page 35.

Type 41P (5 Port/Base mounted) How to Order

A
SS5YJ5–41P– 05 –M5
B

A
B

A, B port
B
A

Number of stations P, R port


B

M5 x 0.8 Applicable solenoid valve


03 3 stations
thread type
P port Refer to page 35.
Nil Rc
1/8 : :
F G
12 12 stations
R port N NPT
Applicable blanking
1/8 T NPTF
plate assembly
SYJ5000-21-3A
Type 43P (5 Port/Base mounted) How to Order
A
SS5YJ5–43P– 05 – C4 Applicable connector
assembly
A

A, B port
B

A
B

B
A

CA P, R port Refer to page 35.


Number of stations
thread type
B

P port 03 3 stations
A, B port size Nil Rc
1/8 : :
C4 One-touch fitting for ø4 F G
R port 12 12 stations N NPT
N3 One-touch fitting for ø5/32"
1/8 T NPTF

Combinations of Solenoid Valve, Manifold Gasket and Manifold Base


Round head combination screw Round head combination screw
M2.5 x 25, M2.5 x 25,
Matt nickel plated Matt nickel plated
(with spring washer) (with spring washer)

Manifold Gasket Manifold Gasket


DXT192-10-14 DXT192-10-16

Blanking Plate Assembly


SYJ5000-21-4A SYJ5000-21-3A
Round head combination screw
Round head combination screw

Blanking plate
Blanking plate

Gasket Gasket

Caution
Applicable manifold base Mounting screw tightening torques
Type SS5YJ5-20 Dust cap
M2.5: 0.45 N·m
Type SS5YJ5-40 Applicable manifold base
Type SS5YJ5-41 Type SS5YJ5-20P Use caution to the assembly orientation for
Type SS5YJ5-42 Type SS5YJ5-41P
Type SS5YJ5-43P solenoid valves, gasket, and optional parts.
Type SS5YJ5-43

37
Series SYJ5000

Mix Installation of the SYJ500 and the SYJ5000 Valves on the Same Manifold Interface Regulator (P port regulation)
 Use of an adapter plate makes it possible to mount Series SYJ500 on the manifold bases of Spacer type regulating valve on manifold block
series SYJ5000. can regulate the pressure to the valve
 When mounting the SYJ500 valve on the SYJ5000 manifold, the SYJ500 solenoid must be posi- individually.
tioned on the same side of the manifold as a single solenoid SYJ500. (Refer to the figure below.)
 For base mounted style, the A port of the 3 port valve flows out the B port of manifold base. ARBYJ5000-00-P
Round head
Adapter Plate Assembly combination
screw
SYJ500-3-2A SYJ500-3-1A
Round head
combination screw

Base mounted

Gasket Round head


Round head Gasket
combination screw
combination screw
Applicable
manifold base
Type SS5YJ5-40
Adapter plate Type SS5YJ5-41
7

Adapter plate Type SS5YJ5-42


7

Adapter gasket Type SS5YJ5-43


Refer to back page 12
Adapter gasket prior to handling.
Applicable manifold base
Type SS5YJ5-40
Applicable manifold base Type SS5YJ5-41
Type SS5YJ5-20 Type SS5YJ5-42
Type SS5YJ5-43

Individual EXH Spacer Assembly Individual SUP Spacer Assembly


SYJ5000-17-1A
SYJ5000--16--2 A
Round head Round head
combination screw combination screw
Thread type
Nil Rc
F G
N NPT
T NPTF
B

A
A

Manifold gasket
Manifold gasket
10

15

P
Individual EXH spacer

Individual SUP spacer

Applicable manifold base Applicable manifold base


Type SS5YJ5-20 Type SS5YJ5-41
Type SS5YJ5-40 Type SS5YJ5-42
Type SS5YJ5-41 Type SS5YJ5-43
Type SS5YJ5-42
Type SS5YJ5-43 Caution
Mounting screw tightening torques
M2.5: 0.45 N·m
Use caution to the assembly orientation for
solenoid valves, gasket, and optional parts.

38
Series SYJ5000

Type 20: Top Ported/SS5YJ5-20- Stations -00 [ ]: AC

Grommet (G)
Approx. 300
(Lead wire length)
13.4
(DIN 14.6)

(Pitch)

2
10 18.5 (DIN 0.8)
P = 16 21

2.5 2.5 12.5


103.2 [107.6]

16.5 15.2

23.5
(DIN 46.8)

87.2 [91.6]
(DIN 46.2)
R

16.5 16.5
A

67.1 [69.3]
67.7 [69.9]
45.6

45

49
P

P
B

B
R

4-ø4.5 1/8
(For mounting) (P, R port)
M5 x 0.8
Manual override L2 9 (A, B port)
L1
Built-in one-touch fitting

(Station n) (Station 1)

(Light/surge voltage suppressor)


48.6 [55.6]

-+ -+ -+ -+ -+
33.2

20

(3.2) 52.8

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)

Max. 10

Applicable cable O.D.


Pg7
ø3.5 to ø7
(Lead wire length)
Approx. 300 59.7 [66.7] M8 x 1
103.4 [107.8]
123 [127.4]
107 [111.4]

87.4 [91.8]

141.2

121.2

106.4
143
125.2

105.2
67.2 [69.4]

90.4
127
77 [79.2]

68.7
76.1
86.1

87

0.6
0.6

35.6
0.6
0.6

33.2
53.1
0.6

0.6

48.6 [55.6] 62.6


73.9
81.4
Refer to back page 11 for dimentions
with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330 346
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328

39
Series SYJ5000

Type 40: Bottom Ported/SS5YJ5-40- Stations -M5 [ ]: AC

Grommet (G)
Approx. 300
(Lead wire length)

L1
L2 9

4-ø4.5
(For mounting)
13

(DIN 22.7) (DIN 22.7)


8.5
(DIN 23.3) (DIN 38.1)
103.2 [107.6]

36.9

16.5

43.6 [45.8] 23.5


21.5 21.5
R

A A A A A

87.2 [91.6]

33
47
P

P
44.2 [46.4]
22.1

B B B B B
R

2.5
1/8
(Pitch) (P, R port)
P = 16 21 Manual override

(Station n) (Station 1)

(Light/surge voltage suppressor) Built-in speed controller


48.6 [55.6]

-+ -+ -+ -+ -+
33.2

20

M5 x 0.8
(A, B port)
12
24

Max. 13.5 43.5


(Pitch)
P = 16 23

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)

Max. 10

Applicable cable O.D.


Pg7 ø3.5 to ø7
(Lead wire length)
Approx. 300 59.7 [66.7] M8 x 1
103.4 [107.8]
123 [127.4]
107 [111.4]

87.4 [91.8]

141.2

121.2

106.4
143
125.2

105.2

90.4
127
43.7 [45.9]
53.5 [55.7]

45.2
52.6
62.6

63.5
0.6

0.6

35.6
0.6
0.6

33.2
62.6 53.1
0.6

0.6

48.6 [55.6]
73.9
81.4

Refer to back page 11 for dimentions


with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330 346
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328

40
Series SYJ5000

Type 41: Side Ported/SS5YJ5-41- Stations -M5 [ ]: AC

Grommet (G)
Approx. 300
(Lead wire length)

L1
4.5 L2 Manual override

2-ø5.5
(For mounting)

12
60.2 [62.4]

59.6 [61.8]
(DIN 6.7) (DIN 38.7)
(DIN 22.1) (DIN 39.3)

87.2 [91.6]
103.2 [107.6]

B B B B B R
38.1

37.5

21
35
3.5 17.5
P

A A A A A

7
20.9

1/8
5.5

(P, R port)

(Pitch)
18 P = 16

Built-in speed controller


(Station 1) (Station n)
Max. 13.5 47.5

(Light/surge voltage suppressor)


52.6 [59.6]

-+ -+ -+
37.2

A A
18.5
24

B B
5.5

(Pitch)
23 P = 16
M5 x 0.8
(A, B port)

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

85.4
77.9
52.6 [59.6] 66.6 M8 x 1
0.6

57.1
0.6

37.2
0.6

39.6
0.6
0.6

0.6
69.5 [71.7]

59.7 [61.9]

79.5
78.6

68.6

61.2
107 [111.4]

87.4 [91.8]
103.4 [107.8]
123 [127.4]

125.2

105.2
127

90.4
141.2

121.2

106.4
143
3.5

3.5
3.5
3.5

Approx. 300 63.7 [70.7]


(Lead wire length)

Pg7
(Lead wire length)

Max. 10

Applicable code O.D.


ø3.5 to ø7
Approx. 300

Refer to back page 11 for dimentions


with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340
L2 43 59 75 91 107 123 139 155 171 187 203 219 235 251 267 283 299 315 331

41
Series SYJ5000
Type 42: Side Ported/SS5YJ5-42- Stations -01, C6
N7  [ ]: AC

Grommet (G) C6
For N7  (Built-in one-touch fitting)
For 01
Approx. 300
(Lead wire length)

L1 Manual override
6.5 L2
2-ø6.5
(For mounting)

17.5 17.5
65.2 [67.4]

64.6 [66.8]
(DIN 44.3)

(DIN 1.7) (DIN 43.7)

87.2 [91.6]
103.2 [107.6]

B B B B B

43.9
43.1

0.5 42.5

24

24
44
23
P

A A A A A

10.5

10.4
( DIN 17.1)
15.9

1/4 1/4
(Pitch) (P, R port)
24.5 P = 17 (P, R port)

(Station 1) (Station n)
(Station 1) (Station n)
(Light/surge voltage suppressor) Built-in speed controller (Light/surge voltage suppressor)
Max. 13.5 56.5
61.6 [68.6]

61.6 [68.6]
-+ -+ -+ -+ -+ -+
46.2

46.2
A A A A
33

33
24.5

25
B B B B

1
8.5

8.5
(Pitch) (Pitch)
24.5 P = 17 1/8 29 P = 16 One-touch fitting
(A, B port) (A, B port)
Applicable tubing O.D.: ø6, ø1/4"

∗ Other dimensions are the same as the grommet type.

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

94.4
61.6 [68.6] 86.9
M8 x 1 66.1
0.6
0.6

75.6
46.2
0.6

0.6

48.6
0.6
0.6
74.5 [76.7]

64.7 [66.9]

84.5
83.6
107 [111.4]

73.6
87.4 [91.8]
103.4 [107.8]

66.2
123 [127.4]

125.2

105.2

90.4
127
141.2

121.2

106.4
143

Approx. 300 72.7 [79.7]


(Lead wire length)
(Lead wire length)

Pg7
Max. 10

Applicable code O.D.


Approx. 300

ø3.5 to ø7

Refer to back page 11 for dimentions


with connector cable.

A, B port size Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 66 83 100 117 134 151 168 185 202 219 236 253 270 287 304 321 338 355 372
For 1/8
L2 53 70 87 104 121 138 155 172 189 206 223 240 257 274 291 308 325 342 359
For L1 65 81 97 113 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353
C6/N7 L2 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340

42
Series SYJ5000

N3 
Type 43: Side Ported/SS5YJ3-43- Stations - C4 [ ]: AC

Grommet (G)
Approx. 300
(Lead wire length)

L1
4.5 L2 Manual override

2-ø5.5
(For mounting)
12 1/8
62.6 [64.8]

(P, R port)

62 [64.2]
(DIN 41.7)

(DIN: 4.3) (DIN: 41.1)

87.2 [91.6]
103.2 [107.6]

R
B B B B B
40.5

39.9

17.5
36.9
1.1 20.2
P

A A A A A

11.4
3.1

(4.4)
(DIN 19.7)

(Pitch)
18 P = 16
18.5

Built-in slottle valve


(Station 1) (Station n)
Max. 13.5 47.5
(Light/surge voltage suppressor)
52.6 [59.6]

-+ -+ -+
37.2

A A
24
18

B B
6

(Pitch)
22.3 P = 16 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
85.4
52.6 [59.6] 77.9
66.6 M8 x 1 57.1
0.6
0.6

37.2
39.6
0.6

0.6

0.6
0.6
72 [74.2]

62.2 [64.4]

81.1

82

63.7
71.1
107 [111.4]

87.4 [91.8]
103.4 [107.8]
123 [127.4]

125.2

90.4
127
141.2

106.4
105.2
143

121.2
1

Approx. 300 63.7 [70.7]


(Lead wire length)
(Lead wire length)

Pg7
Max. 10

Applicable code O.D.


Approx. 300

ø3.5 to ø7

Refer to back page 11 for dimentions


with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340
L2 43 59 75 91 107 123 139 155 171 187 203 219 235 251 267 283 299 315 331

43
Series SYJ5000

Flat Ribbon Cable Manifold [ ]: AC

SS5YJ5-20P- Stations -00

C4 N3
Manual override For C6 N7 (Built-in one-touch fitting)
L1
M5 x 0.8 L2 9
(A, B port) 4-ø4.5
-+

(For mounting)
13.4

-+ -+

2.5 2.5

15.2
12.5

2
123 [127.4]

107 [111.4]
10 18.5

23.5
R

R
One-touch fitting ø6, ø1/4"

16.516.5
A

A
45.6

(A, B port)
77.6 [79.8]

45

49
77 [79.2]
P

65
Applicable tubing O.D.:

82.8
B

16.5
R

ø4, ø5/32", ø6, ø1/4"

-+ -+ -+ -+ -+

Triangle mark
1/8 (3.2) 52.8
(Pitch)
P = 17.5 21 (P, R port)

(Station n) (Station 1)
(Light/surge voltage suppressor)
48.6 [55.6]

25.1
5.8
20

Applicable connector: 26 pins 28.5


With strain relief Station n Station 3 4 5 6 7 8 9 10 11 Station 12
(Conforming to MIL-C-83503) L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 59 76.5 94 111.5 129 146.5 164 181.5 199 216.5

SS5YJ5-41P- Stations -M5


(Pitch)
M5 x 0.8
5.5

P = 17.5 26
(A, B port)
18.5

L1 Built-in slottle valve


Manual override L2 7.5
-+

-+ -+
5.5
3.5
38.1 20.9

12
123 [127.4]

7
107 [111.4]
17.5

A A A A A

5.5
37.5

69.5 [71.7]
70.1 [72.3]

21
35
51

Max. 13.5
68.8

B B B B B

-+ -+ -+ -+ -+

2-ø5.5 Triangle mark 1/8


(For mounting) (Pitch) (P, R port)
P = 17.5 21

(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6 [59.6]

7.8
29.1
24

Applicable connector: 26 pins 28.5


With strain relief Station n Station 3 4 5 6 7 8 9 10 11 Station 12
(Conforming to MIL-C-83503) L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 62 79.5 97 114.5 132 149.5 167 184.5 202 219.5

44
Series SYJ5000

Flat Ribbon Cable Manifold [ ]: AC

SS5YJ5-43P- Stations - N3 
C4

One-touch fitting (Pitch)


(A, B port) P = 17.5 25.3

6
Applicable tubing O.D.:

18
ø4, ø5/32"

L1 Built-in speed controller


Manual override L2 7.5
-+

-+ -+

(4.4)
12

11.4
3.1
40.5 18.5

39.9 1.1
123 [127.4]

107 [111.4]
20.2

A A A A A

5.5

36.9
17.5
71.9 [74.1]
72.5 [74.7]

52.9

Max. 13.5

70.7
B B B B B

-+ -+ -+ -+ -+

4-ø5.5 Triangle mark 1/8


(For mounting) (Pitch) (P, R port)
P = 17.5 21

(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6 [59.6]

7.8
29.1
24

Applicable connector: 26 pins 28.5


With strain relief
(Conforming to MIL-C-83503)

Station n Station 3 4 5 6 7 8 9 10 11 Station 12


L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 62 79.5 97 114.5 132 149.5 167 184.5 202 219.5

45
46
Rubber Seal
5 Port Solenoid Valve

Series SYJ7000 For details about certified products conforming to


Specifications international standards, visit us at www.smcworld.com.

Fluid Air
2 position single 0.15 to 0.7
Operating pressure range
2 position double 0.1 to 0.7
MPa
3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing. Refer to back page 3.)
Response time (ms) Note 1) 2 position single, double 30 or less
(at 0.5 MPa) 3 position 60 or less
Max. operating frequency 2 position single, double 5
(Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Body ported Pilot exhaust method Individual exhaust for the pilot valve, Common exhaust for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
Shock/Vibration resistance (m/s2) Note 2) 150/30
Enclosure Dust proof (∗ DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage,
without surge suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized
states every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test
was performed to axis and right angle directions of the main valve and
armature when pilot signal is ON and OFF. (Value in the initial state)

Base mounted
Solenoid Specifications
JIS Symbol
Body ported Base mounted
2 position single 2 position single solenoid Grommet (G), (H)
(A) (B) (B) (A) L plug connector (L)
4 2 2 4 Electrical entry M plug connector (M)
DIN terminal (D)
5 1 3 3 1 5 M8 connector (W)
(R1) (P) (R2) (R2) (P) (R1)
G, H, L, M, W D
2 position double 2 position double solenoid DC 24, 12, 6, 5, 3 24, 12
Coil rated voltage (V)
(A) (B) (B) (A) AC 50/60 Hz 100, 110, 200, 220
2 4
±10% of rated voltage ∗
4 2
Allowable voltage fluctuation
Standard 0.35 {With light: 0.4 (DIN terminal with light: 0.45)}
5 1 3 3 1 5 Power consumption (W) DC
(R1) (P) (R2) (R2) (P) (R1) With power saving circuit 0.1 (With light only)
100 V 0.78 (With light: 0.81) 0.78 (With light: 0.87)
3 position closed center 3 position closed center
110 V 0.86 (With light: 0.89) 0.86 (With light: 0.97)
(A) (B) (B) (A)
4 2 2 4 ∗ [115 V] [0.94 (With light: 0.97)] [0.94 (With light: 1.07)]
Apparent power VA AC
200 V 1.18 (With light: 1.22) 1.15 (With light: 1.30)
5 1 3 3 1 5 220 V 1.30 (With light: 1.34) 1.27 (With light: 1.46)
(R1) (P) (R2) (R2) (P) (R1) [230 V] [1.42 (With light: 1.46)] [1.39 (With light: 1.60)]
3 position exhaust center 3 position exhaust center Surge voltage suppressor Diode (DIN terminal, Varistor when non-polar types)
(A) (B) (B) (A) Indicator light LED (Neon light when AC with DIN terminal)
4 2 2 4
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
5 1 3 3 1 5 ∗ S, Z and T type (with power saving circuit) should be used within the following allowable voltage fluctuation
(R1) (P) (R2) (R2) (P) (R1) range due to a voltage drop caused by the internal circuit.
S and Z type: 24 VDC: –7% to +10%, 12 VDC: –4% to +10%
3 position pressure center 3 position pressure center T type: 24 VDC: –8% to +10%, 12 VDC: –6% to +10%
(A) (B) (B) (A)
4 2 2 4

5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1)

Made to Order
(For details, refer to pages 79 through to 80.)

47
Series SYJ7000

Flow Characteristics/Weight

Port size Flow characteristics Note 1) Weight (g) Note 2, 3)


Valve model Type of actuation 1, 5, 3 4, 2 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) L/M plug DIN M8
(P, EA, EB) (A, B) C [dm3/(s·bar)] Grommet
b Cv C [dm3/(s·bar)] b Cv connector terminal connector
Single 85 86 107 90
2 position 2.2 0.36 0.58 2.4 0.34 0.63
Double 98 100 142 108
SYJ720--01 Closed center 1/8 1/8 1.8 0.37 0.45 2.0 0.35 0.49
3 position Exhaust center 1.2 0.50 0.34 3.0 [1.3] 0.35[0.52] 0.73 [0.39] 108 110 152 118
Pressure center 3.0 [0.83] 0.37 [0.50] 0.78 [0.25] 1.8 0.37 0.45
Single 96 97 98 101
Body ported

2 position 1.6 0.33 0.4 2.2 0.32 0.53


Double C6 109 111 153 119
SYJ720--C6 Closed center 1/8 (One-touch 1.4 0.27 0.35 1.9 0.33 0.49
3 position Exhaust center fitting for ø6) 1.1 0.37 0.27 2.5 [1.3] 0.32[0.54] 0.61 [0.38] 119 121 163 129
Pressure center 1.8 [0.78] 0.36 [0.40] 0.45 [0.22] 1.6 0.30 0.39
Single 96 97 98 101
2 position 2.0 0.39 0.52 2.3 0.34 0.61
Double C8 109 111 153 119
SYJ720--C8 Closed center 1/8 (One-touch 1.7 0.35 0.42 2.0 0.29 0.49
3 position Exhaust center fitting for ø8) 1.2 0.38 0.33 2.6 [1.3] 0.35[0.49] 0.67 [0.38] 119 121 163 129
Pressure center 1.9 [0.86] 0.57 [0.46] 0.59 [0.25] 1.7 0.39 0.42
Single 165 (85) 166 (86) 187 (107) 170 (90)
2 position 2.3 0.45 0.57 2.8 0.37 0.71
Double 178 (98) 180 (100) 222 (142) 188 (108)
SYJ740--01 Closed center 1/8 1/8 1.9 0.36 0.48 2.1 0.46 0.57
Base mounted

3 position Exhaust center 1.2 0.48 0.35 3.4 [1.3] 0.36[0.57] 0.86 [0.41] 188 (108) 190 (110) 232 (152) 198 (118)
Pressure center 3.3 [0.85] 0.43 [0.54] 0.78 [0.25] 2.1 0.45 0.56
Single 165 (85) 166 (86) 187 (107) 170 (90)
2 position 2.3 0.41 0.61 2.9 0.35 0.74
Double 178 (98) 180 (100) 222 (142) 188 (108)
SYJ740--02 Closed center 1/4 1/4 1.9 0.46 0.50 2.2 0.44 0.60
3 position Exhaust center 1.3 0.45 0.35 3.7 [1.4] 0.27[0.56] 0.87 [0.43] 188 (108) 190 (110) 232 (152) 198 (118)
Pressure center 3.6 [0.83] 0.23 [0.55] 0.84 [0.25] 2.1 0.47 0.58
Note 1) [ ]: denotes the normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate.
Note 3) For DC voltages. For AC voltages add 3 g to the weight of the single solenoid and 6 g to the weight of the double solenoid and 3 position types.

Cylinder Speed Chart


Use as a guide for selection.
Body Ported Please confirm the actual conditions with SMC Sizing Program.
Bore size
Series CJ2 Series MB/CM2 Series MB/CA2
Average speed Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series Load rate: 50%
(mm/s) Load rate: 50% Load rate: 50%
Stroke 60 mm Stroke 300 mm Stroke 500 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
800
700 Perpendicular, upward actuation
600
500 Horizontal actuation
SYJ7120-01 400
300
200
100
0

Base Mounted
Bore size
Series CJ2 Series MB/CM2 Series MB/CA2
Average speed Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series Load rate: 50%
(mm/s) Load rate: 50% Load rate: 50%
Stroke 60 mm Stroke 300 mm Stroke 500 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
800
700 Perpendicular, upward actuation
600
500 Horizontal actuation
SYJ7140-02 400
300
200
100
0
∗ Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
∗ Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
∗ Load factor: ( (Load weight x 9.8) /Theoretical force) x 100%

Conditions
Body ported Series CJ2 Series CM2 Series MB/CA2 Base mounted Series CJ2 Series CM2 Series MB/CA2
Tubing bore x Length ø6 x 1 m ø12 x 1 m Tubing bore x Length ø6 x 1 m
SYJ7120-01 Speed controller AS2301F-06 AS3301F-06 AS4001F-12 SYJ7140-02 Speed controller AS1301F-06 AS3001F-06
Silencer AN110-01 AN200-02 Silencer AN110-01 AN200-02 AN3301F-06

48
Series SYJ7000

How to Order
Light/surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Type of actuation Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
1 2 position single solenoid S With surge voltage suppresor S With surge voltage suppressor (Non-polar type)
2 2 position double solenoid Z With light/surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type)
3 3 position closed center R With surge voltage suppressor (Non-polar type) ∗ DOZ is not available. Bracket
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there
5 3 position pressure center ∗ For AC voltage valves there is no “S” option. is no “S” option. It is already Nil: Without bracket
built-in to the rectifier circuit. F: With bracket
It is already built-in to the rectifier circuit.
∗ For type “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the "Z" type.
Thread type
Nil Rc
F G
Rated voltage
N NPT
DC AC (50/60 Hz)
T NPTF
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC [115 VAC] 01 1/8 Note) Do not remove the
S 5 VDC 4 220 VAC [230 VAC] C6 One-touch fitting for ø6 factory installed
R 3 VDC ∗ For type W, DC bracket from models
C8 One-touch fitting for ø8
with the bracket
∗ DC specifications of type voltage is only N7 One-touch fitting for ø1/4"
available. option. Removal of the
D and DO is only available N9 One-touch fitting for ø5/16" bracket will cause the
(For manifold type 20, 21) with 12 and 24 VDC.
valve to leak. Brackets
cannot be retrofitted.

Body ported SYJ7 1 2 0 5 M 01

Base mounted SYJ7 2 4 0 5 M


Thread type
Body option
Nil Rc
0: Pilot valve individual Coil specifications Manual override F G
exhaust for the pilot valve Nil Standard
Nil: Non-locking push N NPT
With power saving circuit type T NPTF
T
<24 V, 12 VDC only>
∗ Power saving circuit is
For sub-plate, not available in the
manifold type 40, 41, 42 R port P, E port
case of D, DO or W Port size
3: Common exhaust type type.
for main and pilot valve Nil: Without sub-plate

D: Push-turn locking
slotted type
R port P, E port

Electrical entry (With gasket and screws)

24, 12, 6, 5, 3 VDC 24,12 VDC 24, 12, 01: 1/8 With sub-plate
Note)

100,110, 200, 220 VAC 100,110, 200, 220 VAC 6, 5, 3 VDC


Grommet L plug connector M plug connector DIN terminal M8 connector
G: Lead wire L: With lead wire M: With lead wire MN: Without D: With connector WO: Without E: Push-turn locking
(Length 300 mm) lever type
length 300 mm (Length 300 mm) lead wire connector
cable
+- +-

-+ 02: 1/4 With sub-plate


-+

H: Lead wire LN: Without LO: Without MO: Without DO: Without W: With
length 600 mm lead wire connector connector connector connector
cable Note 1)
Note 1) Enter the cable
length symbols in
. Please be sure
-+
to fill in the blank Note) R1, R2 port:
-+

referring to back 1/4


page 10.
∗ LN, MN type: with 2 sockets.
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is also available. For
details, refer to page 80.
∗ For connector cable of M8 connector, refer to back page 10.

49
Series SYJ7000

Construction
(A)(B) (A) (B)
2 position single 4 2 2 position double 4 2

5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
e yq trw w q t r
(A) (B) (A) (B)
4 2 4 2

i i
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)

u
3 position closed center/exhaust center/pressure center
3 position closed center
(A) (B)
4 2

5 1 3
(R1) (P) (R2)
t q rw
3 position exhaust center (A) (B)
(A) (B) 4 2
4 2

5 1 3
(R1) (P) (R2)
3 position pressure center
(A) (B)
4 2 i
5 1 3 5 1 3 (This figure shows a closed center type.)
(R1) (P) (R2) (R1) (P) (R2)

Component Parts Replacement Parts


No. Description Material Note No. Description No. Note
1 Body Aluminum die-casted White Sub-plate SYJ7000-22-1 1/8 Aluminum
7 die-casted
2 Piston plate Resin White SYJ7000-22-2 1/4
3 End cover Aluminum die-casted White 8 Pilot valve V111(T)- ––
4 Piston Resin —
5 Spool valve assembly Aluminum, H-NBR —
6 Spool spring Stainless steel —

How to Order Pilot Valve Assembly

V111 5 G V115 5 D
Coil specifications Light/surge voltage suppressor Rated voltage
Nil Standard Nil Without light/surge voltage suppressor 5 24 VDC
With power saving circuit 6 12 VDC
S With surge voltage suppresor
T 1 100 VAC 50/60 Hz
(24, 12 VDC only) Z With light/surge voltage suppressor 2
Light/surge voltage suppressor
200 VAC 50/60 Hz
∗ Power saving circuit R With surge voltage suppressor (Non-polar type) 110 VAC 50/60 Hz Nil Without light/surge voltage suppressor
3
is not available in the U With light/surge voltage suppressor (Non-polar type) [115 V AC 50/60 Hz] S With surge voltage suppressor (Non-polar type)
case of W type. ∗ For AC voltage valves there is no “S” option. 220 VAC 50/60 Hz Z With light/surge voltage suppressor (Non-polar type)
4
It is already built-in to the rectifier circuit. [230 VAC 50/60 Hz] ∗ DOZ is not available.
Rated voltage ∗ For type R and U, DC voltage is only available. ∗ For AC voltage valves there
5 24 VDC ∗ Power saving circuit is only available in the "Z" type. is no “S” option. It is already
6 12 VDC built-in to the rectifier circuit.
V 6 VDC Electrical entry
S 5 VDC G Grommet, 300 mm lead wire
R 3 VDC H Grommet, 600 mm lead wire
1 100 VAC 50/60 Hz
L With lead wire Electrical entry
2 200 VAC 50/60 Hz L plug
LN Without lead wire D DIN With connector
110 VAC 50/60 Hz connector
3 LO Without connector DO terminal Without connector
[115 VAC 50/60 Hz]
220 VAC 50/60 Hz M With lead wire Note) Do not replace V111 (G,
4 M plug Note 1) Enter the cable H, L, M, W) to V115 (DIN
[230 VAC 50/60 Hz] MN Without lead wire
connector length symbols in . terminal) and vice versa
∗ For type W, DC MO Without connector Please be sure to fill when replacing pilot
voltage is only WO M8 Without connector cable in the blank referring valve assembly only.
available. W connector With connector cable Note 1) to back page 10.
∗ For connector cable of M8 connector,
refer to back page 10.
50
Series SYJ7000

How to Order Connector Assembly


for L/M Plug Connector How to Order M8 Connector Cable

For DC : SY100-30-4A-
V100-49-1-
For 100 VAC : SY100-30-1A-
For 200 VAC : SY100-30-2A- Cable length
1 300 mm
For other
voltages of AC : SY100-30-3A- 2 500 mm
3 1000 mm
4 2000 mm
Without lead wire : SY100-30-A 7 5000 mm
(with connector and 2 of sockets only)

Lead wire length


Nil 300 mm
6 600 mm
10 1000 mm
15 1500 mm
20 2000 mm
25 2500 mm
30 3000 mm
50 5000 mm

51
Series SYJ7000

2 Position Single [ ]: AC

Grommet (G), (H): SYJ7120- GH -01 With bracket:


SYJ7120- GH -01-F
44
2-ø4.5 36 4
(For mounting)

26
34
- +
G: Approx. 300
82 [84.2] H: Approx. 600
59.8 (Lead wire length)
24.1
28.3 39.5 [46.5]
13
3

A B

Manual override
2-ø3.2 17
1/8

85.6 [87.8]
(For manifold mounting) 35 (A, B port)

2-ø3.2 (Light/surge voltage suppressor)


35
(For mounting) (Bracket)

3.6
-+
28
25

16.1
21

31.5 [38.5]

Built-in one-touch fitting:


SYJ7120- GH - C6,
C8, N9  (-F)
N7
R1 P R2
28.3
1.6
18

1/8 27.2 ø1.6 A B


(P, R1, R2 port) (PE port)
17
One-touch fitting
(4.9)

(A, B port)
Applicable tubing O.D. : ø6, ø1/4"
: ø8, ø5/16"
36

(3.6)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ7120-L-01 (-F) SYJ7120-M-01 (-F) SYJ7120-D-01 (-F) SYJ7120-WO-01 (-F)
Approx. 300
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
65
Max. 10

31.5 [38.5]
57.5
16.1 46.2
31.1 M8 x 1 36
(Lead wire length) 18.5
Approx. 300 42.6 [49.6]

Pg7
91.9 [94.1]

101.9
82.1 [84.3]

101

91
83.6
77.1

61.1
35

35

35

35
28.3

28.3

28.3

28.3

21 21 21 21
(3.6)

(3.6)

(3.6)
(3.6)

2-ø3.2 2-ø3.2 2-ø3.2 2-ø3.2


(For mounting) 25 (For mounting) 25 (For mounting) 25 (For mounting) 25
28 28 28 28

Refer to back page 11 for dimentions


with connector cable.

52
Series SYJ7000

2 Position Double [ ]: AC

Grommet (G), (H): SYJ7220- GH -01 Built-in one-touch fitting:


SYJ7220- GH - C6,
C8, N9 
N7

G: Approx. 300
107.4 [111.8] H: Approx. 600
63 (Lead wire length)
3
13

A B A B

Manual override
17 17
2-ø3.2 35 1/8
(For manifold mounting) (A, B port)
One-touch fitting

(4.9)
(A, B port)
2-ø3.2 (Light/surge voltage suppressor) Applicable tubing O.D.: ø6, ø1/4"
(For mounting) 35
: ø8, ø5/16"

36
-+
28
25

16.1
31.5 [38.5]
21
1.6

R1 P R2
18

1/8 27.2 ø1.6


(P, R1, R2 port) (PE port)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ7220-L-01 SYJ7220-M-01 SYJ7220-D-01 SYJ7220-WO-01
Approx. 300
(Lead wire length)

65
31.5 [38.5]
Max. 10

57.5
16.1 46.2
31.1 M8 x 1 36
Approx. 300 42.6 [49.6] 18.5
(Lead wire length)

2-ø3.2
(For mounting) 2-ø3.2
127.2 [131.6]

2-ø3.2 2-ø3.2
107.6 [112]

(For mounting)
(For mounting) (For mounting)
145.4

147.2

125.4
110.6
97.6

65.6
35

35

35

35

21
21
21 25
21 25
28 Pg7
25 25 28
28 Applicable cable O.D.
ø3.5 to ø7 28
Refer to back page 11 for dimentions
with connector cable.

53
Series SYJ7000

3 Position Closed Center/Exhaust Center/Pressure Center [ ]: AC


3
Grommet (G), (H): SYJ7 45 20-GH -01 Built-in one-touch fitting:
3
SYJ7 45 20-GH - C6,
C8, N9 
N7

G: Approx. 300
122 [126.4] H: Approx. 600
54.5 [56.7] (Lead wire length)

45.3 32.3
3
13

A B A B

Manual override
17 17
2-ø3.2 1/8
(For manifold mounting) 35 (A, B port)
One-touch fitting

(4.9)
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"

36
- +
28
25

16.1
21

31.5 [38.5]
1.6

R1 P R2
18

1/8 27.2 ø1.6


(P, R1, R2 port) (PE port)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SYJ7 45 20-L-01 SYJ7 45 20-M-01 SYJ7 45 20-D-01 SYJ7 45 20-WO-01
Approx. 300
(Lead wire length)

65
Max. 10

31.5 [38.5] 57.5


16.1 46.2
31.1 M8 x 1 36
Approx. 300 42.6 [49.6] 18.5
(Lead wire length)
64.4 [66.6]

54.6 [56.8]

74.4
73.5

63.5
56.1
49.6

33.6
141.8 [146.2]

122.2 [126.6]
35

35

35

35
161.8
160

140
46.6
62.6

2-ø3.2 21 2-ø3.2 21 2-ø3.2 21 2-ø3.2 21


69.1

(For mounting) 25 (For mounting) 25 (For mounting) 25 (For mounting) 25

28
28
28
Pg7 28

Applicable cable O.D.


ø3.5 to ø7
Refer to back page 11 for dimentions
with connector cable.

54
Series SYJ7000

2 Position Single [ ]: AC

Grommet (G), (H): SYJ7140- GH - 01


02 

22

12
34 8.5
2-ø4.3
Manual override B A (For mounting)
27
A
B

R2 P R1
With interface regulator
G: Approx. 300 59.8 3.2
H: Approx. 600 85.2 [87.4]
(Lead wire length)
128.8 [131]

(Light/surge voltage suppressor) 1/4, 1/8


(P, A, B port)

80 [87]
57.5 [64.5]

- +

64.6
54
42.1

36.5
25.5

20
12
11.5

18 1/4 22 22 43.6
34 (R1, R2 port) 31.5
63

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ7140-L- 0102  SYJ7140-M- 0102  SYJ7140-D- 01 02 SYJ7140-WO- 0102 

Applicable cable O.D.


(Lead wire length)
Approx. 300

ø3.5 to ø7
91
Max. .10

57.5 [64.5] 83.5


42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
44.5
68.6 [75.6] Approx. 300

20 20 20 20
Pg7
95.1 [97.3]

85.3 [87.5]

104.2

94.2
86.8
80.3
22

22

22

22
64.3
63

63

63

63
22

22

22

22
31.5

31.5

31.5

31.5
3.2

3.2
3.2

3.2

11.5 11.5 11.5 11.5


12 12 12 12
25.5 25.5 25.5 25.5

Refer to back page 11 for dimentions


with connector cable.

55
Series SYJ7000

2 Position Double [ ]: AC

Grommet (G), (H): SYJ7240-GH - 01


02 

22

12
G: Approx. 300
H: Approx. 600 107.4 [111.8]
(Lead wire length) 63
B A

With interface regulator


27
A
B

Manual override R2 P R1

2-ø4.3 34 8.5
(For mounting) 128.8 [131]

(Light/surge voltage suppressor) 1/4, 1/8


(P, A, B port)

80 [87]
57.5 [64.5]

- +

64.6
42.1

36.5
25.5

20
12
11.5

18 1/4 22 22 43.6
34 (R1, R2 port) 31.5
63

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ7240-L- 0102  SYJ7240-M- 0102  SYJ7240-D- 01 02  SYJ7240-WO- 0102 

Applicable cable O.D.


Approx. 300
(Lead wire length)

ø3.5 to ø7
91
57.5 [64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
68.6 [75.6] Approx. 300 44.5

20 20 20 20
127.2 [131.6]

Pg7
107.6 [112]
22

22 22

22
22

147.2

145.4

110.6
125.4
97.6

65.6
63

63

63
63

22

22
22

31.5

31.5

31.5
31.5

11.5 11.5 11.5 11.5


12
12 12 12
25.5
25.5 25.5 25.5
Max. 10

Refer to back page 11 for dimentions


with connector cable.

56
Series SYJ7000

3 Position Closed Center/Exhaust Center/Pressure Center [ ]: AC

3
Grommet (G), (H): SYJ7 45 40- GH - 01
02 

22

12
G: Approx. 300
H: Approx. 600 122 [126.4]
(Lead wire length)
2-ø4.3 36 [38.2]
(For mounting)
B A

27
A

With interface regulator


B

R2 P R1
Manual override 34 8.5
63.8 13.8 129.6 [131.8]

(Light/surge voltage suppressor) 1/4, 1/8


(P, A, B port)

80 [87]
57.5 [64.5]

- +
42.1

36.5
25.5

20
12
11.5

18 1/4 22 22 43.6
34 (R1, R2 port) 31.5
63

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
02 
SYJ7 45 40-L- 01 02 
SYJ7 45 40-M- 01 02 
SYJ7 45 40-D- 01 02 
SYJ7 45 40-WO- 01

Applicable cable O.D.


Approx. 300
(Lead wire length)

ø3.5 to ø7
91
57.5 [64.5] 83.5
42.1 72.2
Pg7 62 M8 x 1
(Lead wire length) 57.1
68.6 [75.6] Approx. 300 44.5

20 20 20 20
141.8 [146.2]

87.6
122.2 [126.6]
81.1
22

22

22 22

22
65.1
161.8
63

63

63

63
160

140
22

22

22
31.5

31.5

31.5

31.5
15.1
45.9 [48.1]

31.1

11.5 11.5 11.5 11.5


37.6
45
55.9

12 12 12 12
55

25.5 25.5 25.5 25.5


36.1 [38.3]

Max. 10

Refer to back page 11 for dimentions


with connector cable.

57
Series SYJ7000
Manifold Specifications
Manifold Standard

Manifold Specifications

Model Type 20 Type 21 Type 40 Type 20 Type 42

Manifold type Single base/B mount


P (SUP), R (EXH) Common SUP, Common EXH
Valve stations 2 to 15 stations 2 to 20 stations
A, B port Location Valve Base Base
Porting specifications Direction Top Bottom Side
P, R port 1/8 1/4
1/8 C6 (One-touch
Port size C6 (One-touch fitting for ø6) fitting for ø6)
A, B port 1/8 C8 (One-touch
C8 (One-touch fitting for ø8)
fitting for ø8)

Flow Characteristics
Flow characteristics
Port size
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
Port Port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 1/8 2.2 0.35 0.57 2.3 0.26 0.55
Type SS5YJ7-20 1/8 C6 1.4 0.32 0.37 2.0 0.25 0.49
Body ported 1/8 C8 1.7 0.38 0.45 2.1 0.25 0.51
SYJ72 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
for internal pilot
Type SS5YJ7-21 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Type SS5YJ7-40 1/4 1/8 2.1 0.28 0.51 2.5 0.23 0.59
Base mounted Type SS5YJ7-41 1/4 1/8 2.0 0.30 0.50 2.2 0.30 0.55
for internal pilot Type SS5YJ7-42-C6 SYJ74 1/4 C6 1.5 0.32 0.38 2.2 0.23 0.52
Type SS5YJ7-42-C8 1/4 C8 1.9 0.24 0.46 2.2 0.26 0.53
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model no.
Example: SS5YJ7-20-03 ······················ 1 pc. (Manifold base)
∗ SYJ7120-5G-01 ··················· 2 pcs. (Valve)
∗ SYJ7000-21-1A ··················· 1 pc. (Blanking plate assembly)

SS5YJ7-41-03-01 ················ 1 pc. (Manifold base)


∗ SYJ7140-5LZ ······················· 1 pc. (Valve)
∗ SYJ7240-5LZ ······················· 1 pc. (Valve)
∗ SYJ7000-21-1A ··················· 1 pc. (Blanking plate assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

58
Series SYJ7000

Flat Ribbon Cable Manifold

 Multiple valve wiring is Flat Ribbon Cable Manifold Specifications


simplified through the use of
the flat cable connector. Model Type 21P
 Clean appearance Manifold type Single base/B mount
In the case of a flat ribbon cable type, each P (SUP), R (EXH) Common SUP, Common EXH
valve is wired on the print board of manifold Valve stations 3 to 12 stations
base to allow the external wiring to be A, B port location Valve
piped all together with 26 pins MIL
P, R port 1/4
connector. Port size
A, B port 1/8, C6, C8
Applicable flat ribbon Socket: 26 pins MIL type with strain relief
cable connector (MIL-C-83503)
Internal wiring In common between +COM and –COM (Z type: +COM only).
Rated voltage 24, 12 VDC
Note 1) The value is for manifold base and individually operated 2 position type.
Note 2) The withstand voltage specification for the wiring unit section is JIS C 0704, Grade 1 or its equivalent.

Flow Characteristics
Flow characteristics
Port size
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
Port Port [dm3/(s·bar)] [dm3/(s·bar)]
Type SS5YJ7-21P-01 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
Body ported
Type SS5YJ7-21P-C6 SYJ723 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
for internal pilot
Type SS5YJ7-21P-C8 1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves, blanking plate assembly and connector assembly to be mounted
on the manifold along with the manifold base model no.
Example:  SS5YJ7-21P-07 ··················· 1 pc. (Manifold base)

∗ SYJ7123-5LOU-C8 ············ 3 pcs. (Valve)


∗ SYJ7223-5LOU-C8 ············ 3 pcs. (Valve)
∗ SYJ7000-21-3A ··················· 1 pc. (Blanking plate assembly)
∗ SY3000-37-3A ······················ 3 pcs. (Connector assembly)
∗ SY3000-37-4A ······················ 3 pcs. (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

How to Order Valve How to Order Connector Assembly


Light/surge voltage suppressor
Rated voltage Z With light/surge voltage suppressor For 12, 24 VDC
5 24 VDC With light/surge voltage suppressor Single solenoid SY3000-37-3A
U
6 12 VDC (Non-polar type) Double solenoid, 3 position type SY3000-37-4A
Note) Z: Positive common specifications only. Single solenoid, individual SUP, EXH spacer SY3000-37-3A
Double solenoid, 3 position individual SUP/EXH spacer SY3000-37-6A
For DC SYJ7 1 23 5 LO Z 01 Interface regulator for single solenoid
Double solenoid, 3 position interface regulator
SY3000-37-3A
SY3000-37-6A
3 port adaptor plate SY3000-37-3A
For AC SYJ7 1 23 1 LOZ 01 For 100 VAC
Single solenoid SY3000-37-32A
Double solenoid, 3 position type SY3000-37-33A
Type of actuation A, B port size Single solenoid, individual SUP, EXH spacer SY3000-37-15A
1 2 position single Symbol Port size Double solenoid, 3 position individual SUP/EXH spacer SY3000-37-34A
2 2 position double 01 1/8 Interface regulator for single solenoid SY3000-37-15A
3 3 position closed center C6 One-touch fitting for ø6 Double solenoid, 3 position interface regulator SY3000-37-34A
4 3 position exhaust center C8 One-touch fitting for ø8 3 port adaptor plate SY3000-37-32A
5 3 position pressure center N7 One-touch fitting for ø1/4"
Rated voltage For 100 VAC (115 VAC)
N9 One-touch fitting for ø5/16"
1 100 VAC Single solenoid SY3000-37-35A
3 110 VAC (115 VAC) Double solenoid, 3 position type SY3000-37-36A
Single solenoid, individual SUP, EXH spacer SY3000-37-19A
Note) In the case of flat cable type, “U” and
Manual override “Z” types are for DC specifications
Double solenoid, 3 position individual SUP/EXH spacer SY3000-37-37A
Nil Non-locking push type and “Z” type is for AC specifications. Interface regulator for single solenoid SY3000-37-19A
D Push-turn locking slotted type “Z” type for DC is positive common Double solenoid, 3 position interface regulator SY3000-37-37A
Push-turn locking lever type specification onlly. For the ohter 3 port adaptor plate SY3000-37-35A
E
combination, please contact SMC.

59
Series SYJ7000
Manifold Standard
/Common SUP/Common EXH
Type 20 (5 Port/Body ported) How to Order
A, B port SS5YJ7–20– 05 – P, R port
Stations thread type
Applicable solenoid valve
Nil Rc
–+
02 2 stations 01
–+
00F G
P port : : SYJ720-- C6
R
P 1/8 00N NPT C8
R
15 15 stations 00T NPTF 01
R port SYJ723-- C6
C8
1/8 Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Applicable blanking
Type 21 (5 Port/Body ported) How to Order
plate assembly
A, B port SS5YJ7–21– 05 – SYJ7000-21-1A

Stations P, R port Applicable individual


thread type
–+ 02 2 stations EXH spacer assembly
–+
Nil Rc
P port : : SYJ7000-17-1A
R
P
00F G
R
1/4 20 20 stations 00N NPT
R port 00T NPTF
1/4 Note) For more than stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 40 (5 Port/Base mounted) How to Order


P port SS5YJ7–40– 05 – 01
1/4
Stations A, B port size Thread type
02 2 stations 01 1/8 Nil Rc
: : F G
R port N NPT
20 20 stations Applicable solenoid valve
1/4 T NPTF
A, B port SYJ740-
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port. SYJ743-
Type 41 (5 Port/Base mounted) How to Order
Applicable blanking
SS5YJ7–41– 05 – 01 plate assembly
SYJ7000-21-1A
P port Stations A, B port size Thread type
–+

–+
1/4 02 2 stations 01 1/8 Nil Rc Applicable individual
B R : : F G EXH spacer assembly
P
R N NPT SYJ7000-17-2A
A 20 20 stations
A, B port T NPTF
B R port
1/4 Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. Applicable individual
SUP spacer assembly
Type 42 (5 Port/Base mounted) How to Order
SYJ7000-16-2A
SS5YJ7–42– 05 – C6
Applicable interface
Stations A, B port size Thread type regulator
C6 One-touch fitting for ø6 Nil Rc
–+

–+ 02 2 stations ARBYJ7000-00-P
P port
B R : : C8 One-touch fitting for ø8 F G
P 1/4
R 20 20 stations N7 One-touch fitting for ø1/4" N NPT
A, B port A
T NPTF
B
R port N9 One-touch fitting for ø5/16"
1/4 Note) For more than stations, supply air to both sides of P port and exhaust air from both sides of R port.

Flat Ribbon Cable Manifold


/Common SUP/Common EXH
Applicable solenoid valve
Type 21P (5 Port/Body ported) How to Order
Refer to page 59.
A, B port SS5YJ7–21P– 05 –
Applicable blanking
A

P, R port plate assembly


B

Stations
A
B

thread type
A

P port SYJ7000-21-3A
B

03 3 stations
B

1/4 Nil Rc
: : Applicable connector
00F G
12 12 stations 00N NPT assembly
00T NPTF Refer to page 59.
R port
1/4 Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

60
Series SYJ7000

Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Mix Installation of the SYJ700 and the SYJ7000 Valves on the Same Manifold
Round head combination screw Round head combination screw  Use of an adapter plate makes it possible to mount Series SYJ700 on the
M3 x 31 M3 x 31 manifold bases of series SYJ7000.
Matt nickel plated Matt nickel plated  When mounting the SYJ700 valve on the SYJ7000 manifold, the SYJ700
(with spring washer) (with spring washer)
solenoid must be positioned on the same side of the manifold as a single
solenoid SYJ700. (Refer to the figure below.)
 For base mounted style, the A port of the 3 port valve flows out the B port
of manifold base.

Adapter plate assembly Adapter plate assembly


SYJ700-3-1A SYJ700-3-2A
SYJ700 SYJ700
Gasket Gasket Series Series
Body ported Base mounted
DXT199-21-10 DXT199-21-11

Applicable manifold base Applicable manifold base Round head


Sub-plate combination screw
Type SS5YJ7-20 Round head
Type SS5YJ7-21 Type SS5YJ7-40
Type SS5YJ7-41 combination screw
Type SS5YJ7-42

Individual EXH Spacer Assembly


SYJ7000-17-1 A Thread type
SYJ7000-17-2 A Thread type
Round head Nil Rc Round head Nil Rc
combination screw F G combination screw F G
N NPT N NPT Gasket
T NPTF T NPTF
Round head
Round head combination screw

7
B B
combination screw

7
A A

Adapter plate Adapter plate

O-ring
Manifold
gasket
15
15

Individual EXH R2 Individual EXH R2


spacer spacer

R
Applicable manifold base Applicable manifold base
R
R1 R1 Type SS5YJ7-20 Type SS5YJ7-40
Type SS5YJ7-21 Type SS5YJ7-41
Type SS5YJ7-42
Manifold Manifold
gasket gasket Blanking Plate Assembly
Applicable manifold base Applicable manifold base SYJ7000-21-1A
Type SS5YJ7-20 Type SS5YJ7-40
Type SS5YJ7-21 Type SS5YJ7-41 Round head combination screw
Type SS5YJ7-42

Individual SUP Spacer Assembly Interface Regulator (P port regulation)


Blanking plate
Spacer type regulating valve on manifold block Applicable
SYJ7000-16-2 A can regulate the pressure to the valve individually.
manifold base
Type SS5YJ7-20
Round head Gasket Type SS5YJ7-21
combination screw ARBYJ7000-00-P Type SS5YJ7-40
Type SS5YJ7-41
Thread type Round head SYJ7000-21-3A Type SS5YJ7-42
Nil Rc combination screw
B F G Round head combination screw
N NPT
A
T NPTF

Blanking plate
Base mounted
Gasket
15

Individual
SUP spacer
Gasket Applicable manifold base
P
Type SS5YJ7-40
P Type SS5YJ7-41
Type SS5YJ7-42
Applicable manifold base Dust cap
Manifold Applicable manifold base
Type SS5YJ7-40
gasket Type SS5YJ7-21P
Type SS5YJ7-41
Type SS5YJ7-42
Refer to back page 12 prior to handling.
Caution
Mounting screw tightening torques Use caution to the assembly orientation for solenoid valves, gasket, and optional parts.
M3: 0.8 N·m

61
Series SYJ7000

Type 20: Top Proted/SS5YJ7-20- Stations -00 [ ]: AC

Grommet (G)
Approx. 300
(Lead wire length)

L1 4-ø4.5
L2 6 (For mounting)

6.5
(DIN 7.8)
(DIN 21.6)

15.5
3
20.3

3.3
8
122 [126.4]

17 16.5

107.4 [111.8]
A

25
R
(DIN 58.6)

(DIN 57.8)

17 17
79.5 [81.7]
57.3

50
56.5

78.7 [80.9]
P
P

R
R

1/8
(P, R port)

Manual override
1/8
(Pitch)
(A, B port)
P = 19 20

Built-in one-touch fitting

(Station n) (Station 1)

(Light/surge voltage suppressor) One-touch fitting


(A, B port)
Applicable tubing O.D.:
55.5 [62.5]

-+ -+ -+ -+ -+
ø6, ø1/4"
ø8, ø5/16"
40.1
23.5

(4.9) 60

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Max. 10

55.5 [62.5] 89
40.1 Pg7 81.5
(Lead wire length)
70.2
Approx. 300 66.6 [73.6] M8 x 1
3.3
3.3

3.3

3.3
141.8 [146.2]

122.2 [126.6]

161.8
127.2 [131.6]

107.6 [112]

125.2
160

140
145.4

147.2

125.4

110.6
78.8 [81]
88.6 [90.8]

80.3
87.7
97.7

98.6
0.8

0.8

42.5
0.8
0.8

60
0.8

0.8

Refer to back page 11 for dimentions


with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 Station 15


L1 59 78 97 116 135 154 173 192 211 230 249 268 287 306
L2 47 66 85 104 123 142 161 180 199 218 237 256 275 294

62
Series SYJ7000

Type 21: Top Ported/SS5YJ7-21- Stations (-00) [ ]: AC

Grommet (G)
Approx. 300
(Lead wire length)

L1
4-ø4.5
L2 10 (For mounting)
(DIN 63.6) (DIN 16.6)

(DIN 2.8)
16.5
3
15.3

11.5

1.5
122 [126.4]

107.4 [111.8]
R
A

30
R

(DIN 62.8)

21
83.7 [85.9]
84.5 [86.7]

61.5
62.3

17

21

60
P
P

21
R
R

1/4
(P, R port)
Manual override (Pitch) 1/8
P = 19 23.5 (A, B port)

Built-in one-touch fitting

(Station n) (Station 1)

(Light/surge voltage suppressor)


One-touch fitting
(A, B port)
58.5 [65.5]

-+ -+ -+ -+ -+
Applicable tubing O.D.:
ø6, ø1/4"
43.1

ø8, 5/16"
26.5

(4.9) 63

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Max. 10

58.5 [65.5] 92
84.5
43.1 Pg7
73.2
(Lead wire length)
Approx. 300 69.6 [76.6] M8 x 1
141.8 [146.2]

122.2 [126.6]
127.2 [131.6]

107.6 [112]

161.8

125.2
160

140
145.4

125.4

110.6
83.8 [86]
93.6 [95.8]

147.2

85.3
92.7
102.7

103.6

0.8
0.8

45.5
0.8
0.8

63
0.8

0.8

Refer to back page 11 for dimentions


with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388

63
Series SYJ7000

Type 40: Bottom Ported/SS5YJ7-40- Stations -01 [ ]: AC

Approx. 300
(Lead wire length)
Grommet (G)
L1 4-ø4.5
L2 10 (For mounting)

(DIN 63.6) (DIN 16.6)


16.5

(DIN 62.8) (DIN 2.8)


11.5
15.3
0.5

1.5
122 [126.4]

107.4 [111.8]
R
A A A A A

30
R

21 21
83.7 [85.9]
84.5 [86.7]
62.3

61.5
21

60
P
P

B B B B B

R
R

1/4
(P, R port)
Manual override (Pitch)
P = 19 23.5
(Station n) (Station 1)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+
58 [65]
42.6
26

B B
19
40

A A

1/8
(A, B port)
(Pitch) 2
P = 19 23.5

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Max. 10

58 [65] 91.5
84
42.6 Pg7
72.7
(Lead wire length)
Approx. 300 69.1 [76.1] M8 x 1
141.8 [146.2]

122.2 [126.6]
127.2 [131.6]

107.6 [112]

161.8

125.2
160

140
145.4

147.2

125.4

110.6
83.8 [86]
93.6 [95.8]

85.3
92.7
102.7

103.6
0.8

0.8

45
0.8

0.8

62.5
0.8
0.8

Refer to back page 11 for dimentions


with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388

64
Series SYJ7000

Type 41: Side Ported/SS5YJ7-41- Stations -01 [ ]: AC

Grommet (G)

Approx. 300
(Lead wire length)
L1
14 L2

31.5
20.5

85.2 [87.4]
86 [88.2]

107.4 [111.8]
R
R
B B B B B
(DIN 65.1)

(DIN 64.3)
122 [126.4]

19 19
63.8

19
63

60
P
P

31.5
22
A A A A A

R
R

1/4
(For DIN:

(P, R port)
15.1)
13.8

4-ø4.5
(Pitch)
29 P = 20 (For mounting)

Manual override

(Station 1) (Station n)
(Light/surge voltage suppressor)

-+ -+ -+
73 [80]
57.6

A A
10.5

41
30.5

B B

6.5 1/8
(Pitch)
25 P = 20 (A, B port)

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
106.5
99
73 [80] 87.7
0.8

M8 x 1 77.5
0.8

57.6 60
0.8

0.8
0.8

0.8
95.1 [97.3]

85.3 [87.5]

105.1
104.2
127.2 [131.6]

94.2
107.6 [112]

86.8
141.8 [146.2]

122.2 [126.6]

145.4

147.2

125.4

110.6
161.8

125.2
160

140

Approx. 300 84.1 [91.1]


(Lead wire length)
(Lead wire length)

Pg7 Applicable cable O.D.


Max. 10

ø3.5 to ø7
Approx. 300

Refer to back page 11 for dimentions


with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 78 98 118 138 158 178 198 218 238 258 278 298 318 338 358 378 398 418 438
L2 50 70 90 110 130 150 170 190 210 230 250 270 290 310 330 350 370 390 410

65
Series SYJ7000

C8,N9 
Type 42: Side Ported/SS5YJ7-42- Stations - C6,N7 [ ]: AC

Grommet (G)

Approx. 300
(Lead wire length)
L1
Manual override
14 L2
4-ø4.5
(For mounting)
32.5
19
85.9 [88.1]

85.1 [87.3]
107.4 [111.8]
(DIN 64.2)
R
B B B B B

R
122 [126.4]

(DIN 65)

18 18.5
62.9
63.7

59.9
21.9 19
P
P

31.4
A A A A A

R
R
(DIN: 15.2)

(4.9)
1/4
13.9

(P, R port)
(Pitch)
29 P = 19

(Station 1) (Station n)
(Light/surge voltage suppressor)

-+ -+ -+
74 [81]
58.6

A A
42
29.5
8.5

B B

8 (Pitch)
25 P = 19 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
107.5
74 [81] 100 M8 x 1
88.7
0.8
0.8

78.5
58.6
0.8

61
0.8

0.8
0.8
95 [97.2]

85.2 [87.4]

104.1
127.2 [131.6]

105
107.6 [112]

94.1
141.8 [146.2]

122.2 [126.6]

86.7
145.4

147.2

125.4

110.6
161.8

125.2
160

140

Approx. 300 85.1 [92.1]


(Lead wire length)
Pg7
(Lead wire length)

Applicable cable O.D.


Max. 10

ø3.5 to ø7
Approx. 300

Refer to back page 11 for dimentions


with connector cable.

Station n Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Station 20


L1 77 96 115 134 153 172 191 210 229 248 267 286 305 324 343 362 381 400 419
L2 49 68 87 106 125 144 163 182 201 220 239 258 277 296 315 334 353 372 391

66
Series SYJ7000

Flat Ribbon Cable Manifold [ ]: AC

SS5YJ7-21P- Stations (-00)

Approx. 300
(Lead wire length)
L1
L2 10

- +
4-ø4.5
(For mounting)
- + - +
16.5
1/8

1.5
15.3

(A, B port)
11.5
141.8 [146.2]

127.2 [131.6]
17 21.5

21 19.5
R
R

30
A

21 21
61.5
62.3

93.6 [95.8]
94.4 [96.6]

60
P
P

93.8
B

R
R

16
- + - + - + - + - +

Manual override (Pitch) Triangle mark 1/4


P = 20.5 23.5 (P, R port)
(Non-locking)

(Station n) (Station 1)
(Light/surge voltage suppressor)
58.5 [65.5]

32.3
26.5

28.5
Applicable connector: 26 pins MIL type
8.8

(Conforming to MIL-C-83503)

For built-in one-touch fitting

One-touch fitting
(A, B port)
Applicable tubing O.D.:
ø6, ø1/4"
ø8, ø5/16"

(4.9) 63

Station n Station 3 4 5 6 7 8 9 10 11 Station 12


L1 88 108.5 129 149.5 170 190.5 211 231.5 252 272.5
L2 68 88.5 109 129.5 150 170.5 191 211.5 232 252.5

67
68
4/5 Port Air Operated Valve

Series SYJA3000
How to Order

Bracket
Nil Without bracket
F With bracket

Body ported SYJA3 1 20 M3

Base mounted SYJA3 2 30 (Manifold use only)


(4 port)

Base mounted SYJA3 2 40


(5 port)

Port size
Type of actuation Nil Without sub-plate
1 2 position single M5 port
M5
2 2 position double With sub-plate
JIS Symbol 3 3 position closed center
4 3 position exhaust center
5 port 4 port
5 3 position pressure center
2 position single 2 position single
(B) (A) (B) (A)
2 4 2 4

3 1 5
1 3
(R) (P) (R)
(P) (R)

2 position double 2 position double How to Order Manifold Base


(B)(A) (B) (A)
2 4 2 4
Same manifolds as series SYJ3000 are prepared.
3 1 5
(R) (P) (R) 1 3
(P) (R)

3 position closed center 3 position closed center SS5YJA3 Fill the same as SS5YJ3
(B) (A) (B) (A)
2 4 2 4

3 1 5 Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
1 3
(R) (P) (R) with the manifold base model no.
(P) (R)

3 position exhaust center 3 position exhaust center


(B) (A) (B) (A)
2 4 2 4
(Example)
SS5YJA3-41-03-M5 ········ 1 pc.
∗ SYJA3140 ······························· 1 pc.
3 1 5
(R) (P) (R)
1 3 ∗ SYJA3240 ······························· 1 pc.
(P) (R)
∗ SYJ3000-21-2A ····················· 1 pc.
3 position pressure center 3 position pressure center
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
(B) (A) (B) (A)
2 4 2 4

3 1 5 1 3
(R) (P) (R) (P) (R)

Caution
Refer to back page 1 through to 5 for Safety
Instructions and Common Precautions.

69
Series SYJA3000

Specifications

Fluid Air
Operating pressure 2 position single 0.15 to 0.7
range 2 position double 0.1 to 0.7
MPa 3 position 0.2 to 0.7
Note 1) 2 position single Operating pressure to 0.7
Pilot pressure range 2 position double 0.1 to 0.7
MPa
Base mounted 3 position 0.2 to 0.7
Ambient and fluid temperature °C –10 to 50 (No freezing. Refer to back page 3.)
Lubrication Not required
Mounting orientation Unrestricted
Note 2)
Impact/Vibration resistance (m/s2) 300/50
Note 1) In case of single type, be certain that pressure within operating pressure range be supplied to
supply port, because return pressure is introduced from supply port {1(P)} for activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
The test was performed on the axis and right angle directions of the
main valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve
when pilot signal is ON and OFF. (Value in the initial state)
Body ported
Pilot Pressure Range (Single pilot) With Bracket

0.6
Air operated
SYJA320-M3-F
Pilot pressure MPa

Pilot pressure valve


0.5
range
The mounting bracket for the 2 position
0.4
double solenoid and 3 position is supplied
unattached.
0.3

0.2

0.1 0.2 0.3 0.4 0.5 0.6


Operating pressure range MPa

Flow Characteristics/Weight ∗ Refer to the memo for changed contents.

Note 3)
Flow characteristics Note 2)
Pilot Weight (g) Effective 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB)
Valve model Type of actuation Port size area
port size C [dm3/ C [dm3/
mm2 b Cv b Cv
Grommet (s • bar)] (s • bar)]
Single 48 (22)
5 port Base mounted

2 position 0.46 0.36 0.12 0.46 0.35 0.12


Double 51 (25)
Closed
(with sub-plate)

0.47 0.33 0.12 0.47 0.31 0.12


center
SYJA340-M5 M5 x 0.8 M3 x 0.5 –
Exhaust 0.59 0.43 0.16
3 position 54 (28) 0.36 0.39 0.10
center [0.40] [0.33] [0.11]
Pressure 0.58 0.42 0.16
0.46 0.32 0.11
center [0.32] [0.33] [0.080]
Single 22
2 position
Double 25
Body ported

Closed
center
SYJA320-M3 M3 x 0.5 M3 x 0.5 0.9
Exhaust
3 position 28
center
Pressure
center
Single 22
4 Port Base Mounted

2 position
(For manifold) Note 1)

Double 25
Closed
SYJA330 center
– M3 x 0.5
Exhaust Note 1) Value when used on a manifold. Refer to page 69 for details.
3 position 28
center Note 2) [ ]: denotes normal position.
Pressure Note 3) ( ): Without sub-plate.
Note 4) 5 port, base mounted without sub-plate: SYJA340
center

70
Series SYJA3000

Dimensions/Body Ported Dimensions/Base Mounted


2 position single: SYJA3120-M3(-F) 2 position single: SYJA3140-M5
10 10

2-ø3.5 (28.4)

5
10
(For mounting) (22)

(16.4)
(10)
2-ø3.2
Manual override (For mounting) 22 4
M3 x 0.5 B A

11
17.5
2.5
M3 x 0.5 ø1 (Bleed port) (Pilot port)
1.5 (Pilot port)

A
B
1.5
M3 x 0.5 33
(Piping port) 36
Manual override
B

R
(35)

7 7
36
(13.5) 7

28.5
P
15
A

21
ø1
R

13
R2 P R1
(Bleed port)

5
4 15 10
(2)

10 10
8.2 11 M5 x 0.8
(Bracket) (Piping port)
14 14
15

2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5

10 9
36
7.1

5
2-M3 x 0.5

10
(Pilot port) 1.8
4

A B
2-ø3.2
1.5

1.5

22
8.2

(For mounting)

2.5
7
2-ø1.8 2-M3 x 0.5 A
B
(For manifold mounting)

11
17.5
2-ø3.2 equivalent (18.5) (Pilot port)

A
B
(For mounting) Manual override
1.5

14

1.5
36
(18.5)
(21)

Manual override
13.5

41.6
15

41.6
28.5
21

R2 P R1
13
(0.5) (11)

R P R
10

2-ø1 (Bleed port) 10 10


7 7 2-ø1 (Bleed port)
M3 x 0.5 M5 x 0.8 28
(Piping port) (Piping port)

3 position closed center/exhaust center/pressure center 3 position closed center/exhaust center/pressure center
3 3
SYJA3 45 20-M3(-F) 7.1
SYJA3 45 40-M5
10 9
2-M3 x 0.5 1.8
5

(Pilot port)
10
4

A B
1.5

7
8.2

19 2-M3 x 0.5
49 2-ø3.2 22 3
2.5

(Pilot port)
(For mounting)
2-ø3.2 equivalent B A
(18.5)
1.5
11
17.5

(For mounting) Manual override


A
B
1.5

33 16
(18.5)
(21)

13.5

18.9
15

Manual override 54.5


21.6
54.5
28.5

2-ø1
21

(Bleed port)
(0.5) (11)

R2 P P1
13

R P R
10

2-ø1 (Bleed port) 10 10


7 7 M5 x 0.8
M3 x 0.5 (Piping port) 14
(Piping port) 28

71
4/5 Port Air Operated Valve

Series SYJA5000
How to Order

A, B port size Bracket


M5 M5 x 0.8 Nil Without bracket
C4 One-touch fitting for ø4 F With bracket
C6 One-touch fitting for ø6

Body ported SYJA5 1 20 M5

Base mounted SYJA5 2 40


Port size Thread type
Type of actuation Nil Without sub-plate Nil Rc
1 2 position single 1/8
01 F G
2 2 position double With sub-plate N NPT
JIS Symbol 3 3 position closed center
T NPTF
Body ported 4 3 position exhaust center
5 3 position pressure center
2 position single 2 position double
(A) (B) (A) (B)
4 2 4 2

5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
3 position closed center 3 position exhaust center
(A) (B) (A) (B)
4 2 4 2
How to Order Manifold Base
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
3 position pressure center Same manifolds as series SYJ5000 are prepared.
(A) (B)
4 2

SS5YJA5 Fill the same as SS5YJ5.


5 1 3
(R1) (P) (R2)
Base mounted
2 position single 2 position double
(B) (A) (B) (A)
2 4 2 4 Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model no.

3 1 3 1
(R) (P) (R) (P)
(Ex.)
3 position closed center 3 position exhaust center
(B) (A)
SS5YJA5-42-03-01 ············ 1 set
(B) (A)
2 4 2 4 ∗ SYJA5140 ······························· 1 set
∗ SYJA5240 ······························· 1 set
3 1
∗ SYJ5000-21-1A ····················· 1 set
3 1
(R) (P) (R) (P)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
3 position pressure center
(B) (A)
2 4

3 1
(R) (P)

Caution
Refer to back page 1 through to 5 for Safety
Instructions and Common Precautions.

72
Series SYJA5000

Specifications
Fluid Air
Operating pressure 2 position single 0.15 to 0.7
range 2 position double 0.1 to 0.7
MPa 3 position 0.15 to 0.7
Note 1) 2 position single (0.4 x P+0.1) to 0.7 P: Operating pressure
Pilot pressure range 2 position double 0.1 to 0.7
MPa
3 position 0.15 to 0.7
Ambient and fluid temperature °C –10 to 50 (No freezing. Refer to back page 3.)
Lubrication Not required
Base mounted Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note 2) 300/50
Note 1) In case of single type, be certain that pressure within operating pressure range be supplied
to supply port, because return pressure is introduced from supply port {1(P)} for activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis
and right angle directions of the main valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve when pilot signal is ON and
OFF. (Value in the initial state)

Pilot Pressure Range (Single pilot) With Bracket


Body ported
0.6
Air operated
SYJA5120-M5-F
valve
Pilot pressure MPa

0.5
Pilot pressure range The mounting brcket is supplied unttached.
0.4

0.3

0.2

0.1 0.2 0.3 0.4 0.5 0.6


Operating pressure range MPa
Flow Characteristics/Weight
Flow characteristics Note 1)
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) Pilot Note 2)
Valve model Type of actuation Port size Weight (g)
C [dm3/ C [dm3/ port size
(s·bar)] b Cv (s·bar)] b Cv
Single
0.47 0.41 0.13 0.47 0.41 0.13
45
2 position Double 60
Closed center 0.49 0.44 0.13 0.44 0.40 0.12
SYJA520-M5 M5 x 0.8
Exhaust 0.47 0.43 0.13 70
3 position 0.46 0.37 0.12
center [0.39] [0.35] [0.10]
Pressure 0.49 0.51 0.14 0.45 0.42 0.12
center [0.39] [0.38] [0.10]
Single
0.69 0.39 0.18 0.44 0.39 0.12
52
2 position Double 67
Body ported

A, B port: C4
Closed center (One-touch 0.69 0.40 0.19 0.43 0.40 0.12
SYJA520-C4 Exhaust fitting for ø4) 0.41 0.37 0.10
M5 x 0.8
3 position P, R port: 0.56 0.40 0.15 77
center [0.41] [0.37] [0.11]
Pressure M5 x 0.8 0.57 0.40 0.15 0.41 0.37 0.10
center [0.41] [0.37] [0.10]
Single 52
2 position 0.70 0.36 0.19 0.47 0.40 0.12
Double 67
A, B port: C6
Closed center (One-touch 0.72 0.37 0.19 0.44 0.34 0.12
SYJA520-C6 fitting for ø6)
Exhaust 0.41 0.38 0.11 77
3 position P, R port: 0.67 0.54 0.19
[0.41] [0.38] [0.11]
center
M5 x 0.8
Pressure 0.82 0.41 0.23 0.41 0.36 0.11
center [0.44] [0.39] [0.12]
Single
0.79 0.21 0.19 0.83 0.32 0.21
79 (45)
2 position
(with sub-plate)

Double 94 (60)
Base mounted

Closed center 0.80 0.28 0.18 0.86 0.34 0.20


SYJA540-01 1/8 M5 x 0.8
Exhaust 1.1 0.24 0.26 104(70)
3 position 0.71 0.26 0.18
center [0.60] [0.44] [0.18]
Pressure 0.99 0.29 0.24 0.72 0.38 0.18
center [0.47] [0.38] [0.12]
Note 1) [ ]: denotes normal position.
Note 2) ( ): Without sub-plate.
Note 3) Model No. for 5 port base mounted style without sub-plate is SYJA540.

73
Series SYJA5000

Dimensions/Body Ported Dimensions/Base Mounted


2 position single: SYJA5120-M5(-F) 2 position single: SYJA5140-01
41.5
2-ø4.3
M5 x 0.8

1
Manual override (For mounting)
15
11
5

A B (Pilot port) B A

1
M5 x 0.8

24
10

A
B
(Pilot port) R P
19
2-ø2.6 2-ø3.5
(Bracket) (For manifold mounting) (For mounting) 37.5 4
42
Manual override 47

(30)
24.5

(37)
23

11.5
20
3

3.5 4 11 2-ø2.6
(18) ø1.8

46.5
19.5 (For mounting) 1/8
(25) (Bleed port)

33.5
(Piping port)
(2.3) (46.5)

21.5
With fiflter
(80 mesh)

8.5
M5 x 0.8

6
6
R1 P
(Piping port) 15 17 17
R2 ø1.8 (Bleed port) 24 45.5
With fiflter (80 mesh) 32
21

2 position double: SYJA5220-M5 2 position double: SYJA5240-01

2-ø4.3
44 2-M5 x 0.8
2-M5 x 0.8 (For mounting)
(Pilot port)
(Pilot port)
B A

1
11

1
5

A B

24
A
B
1

1
10 2-ø2.6 R P

19 (For manifold mounting)


37.5 4
15 42 2
54
47
Manual override 54
24.5
23
20

11.5
3

11 2-ø2.6 Manual override


(For mounting) 2-ø1.8
46.5

(Bleed port) 1/8


33.5

M5 x 0.8 (Piping port)


21.5

With fiflter
R1 P
(Piping port) (80 mesh) 8.5
6
6

R2
2-ø1.8 (Bleed port) 15 17 17
21 With fiflter (80 mesh) 24 45.5
32

3 position closed center/exhaust center/pressure center 3 position closed center/exhaust center/pressure center
3 3
SYJA5 45 20-M5 27.6 SYJA5 45 40-01 2-M5 x 0.8 2-ø4.3
37.4 2-M5 x 0.8 22.6 (Pilot port) (For mounting)
(Pilot port)
B A
11
5

A B
24
1

A
1

10 2-ø2.6
R P

19 (For manifold mounting) 37.5 4


15 43
70 48 17.5
Manual override 70.5
24.5
23
20

11.5
3

11 2-ø2.6
1/8
46.5

(For mounting) Manual override


33.5

(Piping port)
M5 x 0.8
21.5

(Piping port)
2-ø1.8
(Bleed port)
6

R1 P
15 With fiflter
17 17
8.5

R2 24 (80 mesh)
45.5
2-ø1.8 (Bleed port) 32
21
With fiflter (80 mesh)

74
4/5 Port Air Operated Valve

Series SYJA7000
How to Order

A, B port size Bracket


01 1/8 Nil Without bracket
C6 One-touch fitting for ø6 F With bracket
C8 One-touch fitting for ø8

Body ported SYJA7 1 20 01

Base mounted SYJA7 2 40


Port size Thread type
Type of actuation Nil Without sub-plate Nil Rc
1 2 position single 1/8
01 F G
JIS Symbol 2 2 position double With sub-plate
N NPT
Body ported 3 3 position closed center 1/4
02 T NPTF
4 3 position exhaust center With sub-plate
2 position single 2 position double 5 3 position pressure center
(A) (B) (A) (B)
4 2 4 2

5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
3 position closed center 3 position exhaust center
(A) (B) (A) (B)
4 2 4 2
How to Order Manifold Base
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
3 position pressure center Same manifolds as series SYJ7000 are prepared.
(A) (B)
4 2

SS5YJA7 Fill the same as SS5YJ7.


5 1 3
(R1) (P) (R2)

Base mounted
2 position single 2 position double Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
(B) (A) (B) (A) with the manifold base model no.
2 4 2 4

3 1 5 3 1 5 (Ex.)
(R2) (P) (R1) (R2) (P) (R1) SS5YJA7-41-03-01 ········· 1 pc.
3 position closed center 3 position exhaust center ∗ SYJA7140 ······························ 1 pc.
(B) (A) (B) (A)
2 4 2 4 ∗ SYJA7240 ······························ 1 pc.
∗ SYJ7000-21-1A ··················· 1 pc.
3 1 5 3 1 5
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
(R2) (P) (R1) (R2) (P) (R1)

3 position pressure center


(B) (A)
2 4

3 1 5
(R2) (P) (R1)

Caution
Refer to back page 1 through to 5 for Safety
Instructions and Common Precautions.

75
Series SYJA7000

Specifications

Fluid Air
Operating pressure 2 position single 0.15 to 0.7
range 2 position double 0.1 to 0.7
MPa 3 position 0.15 to 0.7
Note 1) 2 position single (0.4 x P+0.1) to 0.7 P: Operating pressure
Pilot pressure range 2 position double 0.1 to 0.7
MPa
3 position 0.15 to 0.7
Ambient and fluid temperature °C –10 to 50 (No freezing. Refer to back page 3.)
Base mounted Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note 2) 300/50
Note 1) In case of single type, be certain that pressure within operating pressure range be supplied to
supply port, because return pressure is introduced from supply port {1(P)} for activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
The test was performed on the axis and right angle directions of the
main valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve
when pilot signal is ON and OFF. (Value in the initial state)

Body ported
Pilot Pressure Range (Single pilot) With Bracket

0.6
Air operated
SYJA7120-01-F
valve
0.5
Pilot pressure MPa

Pilot pressure range As a bracket is designed for a body, be sure


0.4 that a bracket is attached when ordering and
operating.

0.3

0.2

0.1 0.2 0.3 0.4 0.5 0.6

Operating pressure range MPa

76
Series SYJA7000

Flow Characteristics/Weight

Flow characteristics Note 2) Note 3)

Valve model Type of actuation Port size 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) Pilot Weight
port size (g)
C [dm3/ b Cv C [dm3/
(s • bar)] (s • bar)] b Cv
Single 90
2 position 2.2 0.36 0.58 2.4 0.34 0.63
Double 110
Closed
1.8 0.37 0.45 2.0 0.35 0.49
center
SYJA720-01 1/8
Exhaust 3.0 0.35 0.73
3 position 1.2 0.50 0.34 120
center [1.3] [0.52] [0.39]
Pressure 3.0 0.37 0.78
1.8 0.37 0.45
center [0.83] [0.50] [0.25]
Single 101
2 position 1.6 0.33 0.4 2.2 0.32 0.53
Double 121
Closed
Body ported

A, B port: C6 1.4 0.27 0.35 1.9 0.33 0.49


center (One-touch
SYJA720-C6 fitting for ø6) M5 x 0.8
Exhaust 2.5 0.32 0.61
3 position P, R port: 1/8 1.1 0.37 0.27 131
center [1.3] [0.54] [0.38]
Pressure 1.8 0.36 0.45
1.6 0.30 0.39
center [0.78] [0.40] [0.22]
Single 101
2 position 2.0 0.39 0.52 2.3 0.34 0.61
Double 121
Closed
A, B port: C8 1.7 0.35 0.42 2.0 0.29 0.49
center (One-touch
SYJA720-C8 Exhaust fitting for ø8) 2.6 0.35 0.67
3 position P, R port: 1/8 1.2 0.38 0.33 131
center [1.3] [0.49] [0.38]
Pressure 1.9 0.57 0.59
1.7 0.39 0.42
center [0.86] [0.46] [0.25]
Single 170 (90)
2 position 2.3 0.45 0.57 2.8 0.37 0.71
Double 190 (110)
Closed
1.9 0.36 0.48 2.1 0.46 0.57
center
Base mounted (with sub-plate)

SYJA740-01 1/8 Note 1) M5 x 0.8


Exhaust 3.4 0.36 0.86
3 position 1.2 0.48 0.35 200 (120)
center [1.3] [0.57] [0.41]
Pressure 3.3 0.43 0.78
2.1 0.45 0.56
center [0.85] [0.54] [0.25]
Single 170 (90)
2 position 2.3 0.41 0.61 2.9 0.35 0.74
Double 190 (110)
Closed
1.9 0.46 0.50 2.2 0.44 0.60
center
SYJA740-02 1/4 Note 1) M5 x 0.8
Exhaust 3.7 0.27 0.87
3 position 1.3 0.45 0.35 200 (120)
center [1.4] [0.56] [0.43]
Pressure 3.6 0.23 0.84
2.1 0.47 0.58
center [0.83] [0.55] [0.25]
Note1) P, A, B port: Rc1/8 is R1, R2 port: Rc (PT) 1/4
Note2) [ ]: for nomal position
Note3) ( ): without sub-plate
Note4) Model No. for base mounted style without sub-plate is SYJA40.

77
Series SYJA7000

Dimensions/Body Ported Dimensions/Base Mounted


2 position single: SYJA7120-01(-F) 02 
2 position single: SYJA7140- 01
60.1
28.3 2-ø4.3
M5 x 0.8 (For mounting)
(Pilot port)

1
B A
13
3

A B

34
27
B
17 M5 x 0.8

A
2-ø3.2
(For manifold mounting) 35 (Pilot port) R2 P R1

2-ø3.2 (For mounting) 2-ø4.5 (For mounting) 34 8.5


(Bracket) (6.8) 35 18 63.3
68.8
Manual override
1/8,1/4
15
29

(44)

(P, A, B port)
(36)
21

14
65.6
(69.2)

54
55
(31.9) (26) ø1.8

40
25.5
1/8 (Bleed port)

20
(34)

11.5
12
(Piping port) With fiflter
R1 P R2 Manual override (80 mesh)
18
1.6

22 22
1/4
ø1.8 (Bleed port) 31.5
27.2 (R1, R2 port)
With fiflter (80 mesh) 63

2 position double: SYJA7240- 02 


01
2 position double: SYJA7220-01 2-ø4.3
63.6 (For mounting)
2-M5 x 0.8 34 8.5
1

(Pilot port)
13
3

B A
A B

1
1

34
27
2-ø3.2 17 2-M5 x 0.8

A
B

1
(For manifold mounting) 35 (Pilot port)
R2 P R1

2-ø3.2 31.5
35 (For mounting) 18 63.6
Manual override
74.6
28
29
25

21

14

74.6
Manual override
55

1/8
2-ø1.8
40
25.5

(Piping port)
(Bleed port)

20
1.6

12
R1 P With fiflter 11.5
R2

18 (80 mesh) 22 22
2-ø1.8 (Bleed port) 63 1/4
27.2
With fiflter (80 mesh) (R1, R2 port)
1/8,1/4
(P, A, B port)

3 position closed center/exhaust center/pressure center 3 position


3
closed center/exhaust center/pressure center
3 2-ø4.3
SYJA7 45 40- 02 
01
SYJA7 45 20-01 2-ø3.2 (For mounting)
35 34 8.5
(For manifold mounting)
17 2-M5 x 0.8
(Pilot port)
B A
1

34
27
13

A B
1
3

1
1

R2 P R1
45.6 32.6 2-M5 x 0.8
38.1 31.5
2-ø3.2 (Pilot port) 64
(For mounting) 35 Manual override 69.5 14
89
Manual override 1/8,1/4
29
28
25

(P, A, B port)
21

14

89.2
18
2-ø1.8 (Bleed port)
55

With fiflter (80 mesh)


2-ø1.8
40
25.5

(Bleed port)
20
1.6

11.5
12

R1 P R2
With fiflter
18 (80 mesh) 22 22
27.2 63 1/4
1/8 (R1, R2 port)
(Piping port)

78
Series SYJ5000/7000
Made to Order
(For detailed specifications, delivery and pricing, please contact SMC.)

Body Ported External Pilot

Applicable solenoid valve series SYJ520R, SYJ720R

SYJ 5
7 20R X20

Entry is the same as standard products.

Operating Pressure Range MPa External Pilot Port


Operating pressure range -100 kPa to 0.7 Series Port size
Pilot pressure range 0.15 to 0.7 SYJ5000, SYJ7000 M5 x 0.8

Dimensions
SYJ5000: 8 mm
longer in total length.
SYJ7000: 8 mm

JIS Symbol
Body ported
2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center
(A)(B) (A)(B) (A)(B) (A)(B) (A)(B)
4 2 4 2 4 2 4 2 4 2

5 1 3 5 1 3 5 1 3 5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2) (R1) (P) (R2) (R1) (P) (R2) (R1) (P) (R2)

X X X X X

79
Series SYJ5000/7000
Made to Order
DIN Connector Conforming to EN-175301-803C (former DIN 43650C)
DIN connector type that conforms to the 8 mm pitch standards between DIN terminals.
How to Order Valve
Light/surge voltage suppressor
Type of actuation
Nil Without light/surge voltage suppressor
1 2 position single solenoid
S With surge voltage suppressor
2 2 position double solenoid
Z With light/surge voltage suppressor Bracket
3 3 position closed center
∗ YOZ is not available. Nil Without bracket
4 3 position exhaust center ∗ For AC voltage valves there is no “S” option. F With bracket
5 3 position pressure center It is already built-in to the rectifier circuit.
Rated Note) Do not remove the factory
voltage installed bracket from
DC AC (50/60 Hz) models with the bracket
5 24 VDC 1 100 VAC
A, B port size option. Removal of he
M5 M5 x 0.8 bracket will cause the
6 12 VDC 2 200 VAC
01 1/8 (SYJ7000 only) valve to leak.
3 110 VAC [115 VAC]
4 220 VAC [230 VAC] C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
N3 One-touch fitting for ø5/32"
N7 One-touch fitting for ø1/4"

Body ported SYJ 5 1 2 0 5 Y M5

Base mounted SYJ 5 2 4 0 5 Y


Electrical entry Thread type
Nil Rc
Body option Y: With F G
connector
0: Pilot valve individual 3: Common exhaust N NPT
exhaust for the pilot type for main and T NPTF
valve pilot valve Port size
Nil Without sub-plate
SYJ5000
01 1/8
SYJ7000
YO: Without 02 1/4 SYJ7000
Series connector
5 SYJ5000 R port P, E port R port P, E port Manual override
7 SYJ7000 Nil Non-locking push type
D Push-turn locking slotted type
E Push-turn locking lever type

How to Order Pilot Valve Assembly

V115 5 Y DIN Connector Part No.


Without light SY100-82-1
Rated voltage With light
Rated voltage Voltage symbol No.
DC 24 VDC 24 VN SY100-82-3-05
5 24 VDC 12 VDC 12 VN SY100-82-3-06
Light/surge voltage suppressor
6 12 VDC 100 VAC 100 VN SY100-82-3-01
Nil Without light/surge voltage suppressor
AC (50 60 Hz) 200 VAC 200 VN SY100-82-3-02
S With surge voltage suppressor
1 100 VAC With light/surge voltage suppressor 110 VAC (115 VAC) 110 VN SY100-82-3-03
Z
2 200 VAC 220 VAC (230 VAC) 220 VN SY100-82-3-04
∗ YOZ is not available.
3 110 VAC [115 VAC] ∗ For AC voltage valves there is no
4 220 VAC [230 VAC] “S” option. It is already built-in to Caution
the rectifier circuit. 1. Use caution in wiring because it won't meet the IP65 (enclosure) standard if you
use the other cord than prescribed heavy-duty cord of size (ø3.5 to ø7.5). Also be
sure to tighten the ground nut and holding screw with the prescribed torque
range.Tighten the ground nut and set screw within the specified range of torque.
Electrical entry For how to use DIN terminal (wiring procedures, procedures for changing electrical
entries, precautions, applicable cable, circuit diagram), refer to back page 8.
Y DIN With connector 2. D type DIN connector with 9.4 mm pitch between terminals is not interchangeable.
YO terminal Without connector 3. DIN connector except D type has the “N” indication in the end of voltage symbol. In
case of DIN connector without light, “N” is not indicated. Please refer to the name
plate to distinguish.
4. Dimensions are completely the same as D type connector.
5. When exchanging the pilot valve assembly only, “V115-D” is interchangeable
with “V115-Y”. Do not replace V114 (G, H, L, M, W) to V115-D/Y (DIN
terminal), and vice versa.

80
Series SYJ
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by labels of
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1),
JIS B 8370 Note 2) and other safety practices.

Caution : Operator error could result in injury or equipment damage.


Warning : Operator error could result in serious injury or loss of life.
Danger : In extreme conditions, there is a possible result of serious injury or loss of life.

Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems.


Note 2) JIS B 8370: General Rules for Pneumatic Equipment

Warning
1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements. The expected performance and safety assurance will be the responsibility of the
person who has determined the compatibility of the system. This person should continuously review
the suitability of all items specified, referring to the latest catalog information with a view to giving due
consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery
and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driver objects have been confirmed.
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston
rod, etc.
4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and
brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.

Back page 1
4/5 Port Solenoid Valves/Common Precautions 1
Be sure to read before handling.

Design Selection

Warning Warning
1. Actuator drive 1. Confirm the specification
When an actuator, such as a cylinder, is to be driven using a The products presented in this catalog are designed only for
valve, take appropriate measures to prevent potential danger use in compressed air systems (including vacuum). Do not
caused by actuator operation. operate at pressures or temperatures, etc., beyond the range
2. Intermediate stopping of specifications, as this can cause damage or malfunction.
(Refer to specifications.)
When a 3 position closed center valve is used to stop a
Contact SMC when using a fluid other than compressed air
cylinder at an intermediate position, accurate stopping of the
(including vacuum).
piston in a predetermined position is not possible due to the
compressibility of air. Furthermore, since valves and cylinders 2. Extended periods of continuous energization
are not guaranteed for zero air leakage, it may not be possible • Continuous energization of the valve for extended periods of
to hold a stopped position for an extended length of time. time may have an adverse effect on the solenoid valve
Contact SMC if it is necessary to hold a stopped position for performance and the peripheral equipment due to
an extended time. temperature rises caused by the heat generation of the coil.
3. Effect of back pressure when using a Consult with SMC if valves will be continuously energized for
extended periods of time or the energized period per day will
manifold be longer than the de-energized period. It is also possible to
Use caution when valves are used on a manifold, as actuator shorten the energization period by using valves of the N.O.
malfunction due to back-pressure may occur. In case of 3 (normally open) type.
position closed exhaust center valve or single acting cylinder, • When solenoid valves are mounted in a control panel,
take appropriate measures to prevent the malfunction using employ measures to radiate excess heat, so that
with individual EXH interface assembly or individual exhaust temperatures remain within the valve specification range.
manifold. Use special caution when three or more stations sequentially
4. Holding of pressure (including vacuum) aligned on the manifold are continuously energized since
Since valves are subject to air leakage, they cannot be used this will cause a drastic temperature rise.
for applications such as holding pressure (including vacuum) (As for AC specifications, since the applicable products are
in a pressure vessel. ready to provide separately, contact SMC.)
5. Cannot be used as an emergency shut off
valve, etc.
The valves presented in this catalog are not designed for Caution
safety applications such as an emergency shut off valve. If the 1. Momentary energization
valves are used in this type of system, other reliable safety
If a double solenoid valve will be operated with momentary
assurance measures should also be adopted.
energization, it should be energized for at least 0.1 second.
6. Maintenance space However, depending on the secondary load conditions, it
The installation should allow sufficient space for maintenance should be energized until the cylinder reaches the stroke end
activities (removal of valve, etc.). position, as there is a possibility of malfunction otherwise.
7. Release of residual pressure 2. Leakage voltage
Provide a residual pressure release function for maintenance When using a resistor in paral- Switching element
OFF
purpose. Especially in case of 3 position closed center valve, lel with the switching element
C R
or using a C-R element (surge
Leakage

ensure the release of residual pressure between valve and


supply
Power

voltage

Valve
cylinder. voltage suppressor) for protec- Leakage current
tion of the switching element,
8. Vacuum applications note that leakage voltage will
When a valve is used for vacuum switching, etc., take increase due to leakage current flowing through the resistor or
measures against the suction of external dust or other C-R element. Limit the amount of residual leakage voltage to
contaminants from vacuum pads and exhaust ports, etc. the following value:
Moreover, an external pilot type valve should be used in this
case. Contact SMC in case of an internal pilot type or air With DC coil : 3% or less of rated voltage
operated valve, etc.
With AC coil : 8% or less of rated voltage
9. About using the double solenoid type
When using the double solenoid type for the first time,
actuators may travel in an unexpected direction depending on
the switching position of a valve. Implement countermeasures
not to occur any danger by the actuator's operation.
10. Ventilation
When a valve is used inside a sealed control panel, etc.,
provide ventilation to prevent a pressure increase caused by
exhausted air inside the control panel or temperature rise
caused by the heat generated by the valve.

Back page 2
4/5 Port Solenoid Valves/Common Precautions 2
Be sure to read before handling.

Selection Port Direction

Caution Caution
3. Solenoid valve drive for AC with solid state 1. Preparation before piping
output (SSR, TRIAC output, etc.) Before piping is connected, it should be thoroughly blown out
with air (flushing) or washed to remove chips, cutting oil and
1) Current leakage
other debris from inside the pipe.
When using a snubber circuit (C-R element) for surge
protection of the output element, a very small electric 2. Wrapping of sealant tape
current will still continue to flow in spite of the OFF state. When connecting pipes and fittings, etc., be sure that chips
This results in the valve not returning. In the cases when from the pipe thread and sealing materials do not get inside
exceeding the tolerance as shown above, take measures to the valve. Furthermore, when pipe tape is used, leave 1.5 to 2
install a bleeder resistor. thread ridges exposed at the end of the threads.
2) Minimum load allowable amount (Min. load current)
Winding
When the consumption current of a valve is less than the direction
output element’s minimum load allowable volume or the
margin is small, the output element may not be switched
normally. Please confirm SMC. Ex
po Pipe tape
se
4. Surge voltage suppressor thr app
ea ro
If a surge protection circuit contains non-ordinary diodes such ds x.
2
as Varistor, a residual voltage that is in proportion to the
protective elements and the rated voltage will remain. 3. Closed center valves
Therefore, give consideration to surge voltage protection of the
controller. In the case of diodes, the residual voltage is When using closed center type valves, carefully check to
approximately 1 V. ascertain that there is no air leakage from the piping between
the valves and cylinders.
5. Use in low temperature environments
Unless otherwise indicated in the specifications for each valve,
4. Screwing in fittings
operation is possible to –10°C, but appropriate measures When connecting fittings to valves, tighten as indicated below.
should be taken to avoid solidification or freezing of drainage 1) For M3 and M5 type
and moisture, etc. (1) When using SMC fittings, follow the guidelines below.
After tightening by hand, tighten an additional M3: 1/4,
6. Operation for air blowing M5: 1/6 turn with a tightening tool. However, if miniature
When using a solenoid valve for air blow, use an external pilot fittings are used, tighten an additional 1/4 turn with a
type. tightening tool after tightening by hand. For fittings with
Take note that when internal pilots and external pilots are used gaskets in 2 locations, e.g., universal elbow or universal
on the same manifold, the pressure drop caused by the air tee, tighten an additional 1/2 turn.
blowing can have an effect on the internal pilot type valves. Note) If fittings are over-tightened, air leakage may result
Moreover, when compressed air within the pressure range of due to breaking of fitting threads or deformation of the
the established specifications is supplied to the external pilot gaskets. However, if fittings are not tightened
port, and a double solenoid valve is used for air blowing, the sufficiently, loosening of the threads and air leakage
solenoids should normally be energized when air is being and may occur.
blown.
(2) When fittings other than SMC fittings are used, follow the
7. Mounting orientation instructions of the respective fitting manufacturer.
Rubber seal: Refer to the specifications of each series. 2) For Rc (PT)
When installing fitting, etc., follow the given torque levels
below.
Mounting Tightening Torque for Piping
Connection threads Applicable tightening torque N·m
Warning 1/8 7 to 9
1. If air leakage increases or equipment does 1/4 12 to 14
not operate properly, stop operation. 3/8 22 to 24
Check mounting conditions when air and power supplies are 1/2 28 to 30
connected. Initial function and leakage tests should be 3/4 28 to 30
performed after installation.
1 36 to 38
2. Instruction manual 11/4 40 to 42
Mount and operate the product after reading the manual 11/2 48 to 50
carefully and understanding its contents. 2 48 to 50
Also keep the manual where it can be referred to as necessary.
3. Painting and coating 5. Connection of piping to products
Warnings or specifications printed or pasted on the product When connecting piping to a product, refer to its instruction
should not be erased, removed or covered up. Consult with manual to avoid mistakes regarding the supply port, etc.
SMC if paint is to be applied to resinous parts, as this may
have an adverse effect due to the paint solvent.

Back page 3
4/5 Port Solenoid Valves/Common Precautions 3
Be sure to read before handling.

Wiring Air Supply

Caution Caution
1. Polarity 1. Install air filters.
When connecting power to a DC specification solenoid valve Install air filters close to valves at their upstream side. A
equipped with (indicator light) surge voltage suppressor, filtration degree of 5 µm or less should be selected.
confirm whether or not there is polarity. 2. Install an air dryer, after cooler or Drain
If there is polarity, take note of the following points.
Without built-in diode to protect polarity (including any power
Catch (water separator), etc.
saving circuit): Air that includes excessive drainage may cause malfunction of
If a mistake is made regarding polarity, the diode in the valves and other pneumatic equipment. To prevent this, install
valve, the control device switching element or power supply an air dryer, after-cooler or Drain Catch (water separator), etc.
equipment, etc., may burn out. 3. If excessive carbon dust is generated,
With diode to protect polarity: eliminate it by installing mist separators at
If a mistake is made regarding polarity, it will not be possible the upstream side of valves.
to switch the valve.
If excessive carbon dust is generated by the compressor, it
2. Applied voltage may adhere to the inside of valves and cause malfunction.
When electric power is connected to a solenoid valve, be Refer to “SMC Best Pneumatics” catalog Vol. 14 for compressed
careful to apply the proper voltage. Improper voltage may air quality.
cause malfunction or coil damage.
3. Confirm the connections.
After completing the wiring, confirm that the connections are Operating Environment
correct.
Warning
Lubrication 1. Do not use valves in atmospheres of
corrosive gases, chemicals, salt water, water
Caution or steam or where there is direct contact
1. Lubrication with any of these.
[Rubber seal] 2. Products with IP65 enclosures (based on
1) The valve has been lubricated for life at the factory, and IEC60529) are protected against dust and
does not require any further lubrication. water, however, these products cannot be
2) In the event that it is lubricated, use class 1 turbine oil used in water.
(without additives), ISO VG32. Take measures to prevent water and dust
However, once lubrication is applied it must be continued,
as loss of the original lubricant may lead to malfunction. from coming from the exhaust port.
Contact SMC regarding class 2 turbine oil (with additives), 3. Products compliant to IP65 satisfy the
ISO VG32. specifications by mounting each product
properly. Be sure to read the Specific
Air Supply Product Precautions for each product.
4. Do not use in an explosive atmosphere.
Warning 5. Do not use in locations subject to vibration
1. Use clean air. or impact. Confirm the specifications in the
Do not use compressed air which contains chemicals, main section of the catalog.
synthetic oils containing organic solvents, salts or corrosive 6. A protective cover, etc., should be used to
gases, etc., as this can cause damage or malfunction.
shield valves from direct sunlight.
7. Shield valves from radiated heat generated
by nearby heat sources.
8. Employ suitable protective measures in
locations where there is contact with water
droplets, oil or welding spatter, etc.
9. When solenoid valves are mounted in a
control panel or are energized for extended
periods of time, employ measures to radiate
excess heat, so that temperatures remain
within the valve specification range.

Back page 4
4/5 Port Solenoid Valves/Common Precautions 4
Be sure to read before handling.

Maintenance

Warning
1. Perform maintenance procedures as shown
in the instruction manual.
If handled improperly, malfunction or damage of machinery or
equipment may occur.
2. Equipment removal and supply/exhaust of
compressed air
When equipment is removed, first confirm that measures are
in place to prevent dropping of work pieces and run-away of
equipment, etc. Then cut the supply pressure and power, and
exhaust all compressed air from the system using its residual
pressure release function.
In the case of 3 position closed center style, exhaust the
residual pressure between valve and cylinder.
When the equipment is to be started again after remounting or
replacement, first confirm that measures are in place to
prevent lurching of actuators, etc., and then confirm that the
equipment is operating normally.
3. Low frequency operation
Valves should be switched at least once every 30 days to
prevent malfunction. (Use caution regarding the air supply.)
4. Manual override operation
When the manual override is operated, connected equipment
will be actuated. Confirm safety before operating.

Caution
1. Drain flushing
Remove drainage from air filters regularly.

Back page 5
Series SYJ3000/5000/7000
Specific Product Precautions 1
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Manual Override Operation Solenoid Valve for 200 V, 220 VAC Specifications

Warning Warning
When the manual override is operated, connected equipment Solenoid valves with grommet and L/M type plug connector AC
will be actuated. Confirm safety before operating. specifications have a built-in rectifier circuit in the pilot section to
operate the DC coil.
With 200 V, 220 VAC specification pilot valves, this built-in
 Non-locking push type [Standard] rectifier generates heat when energized. The surface may
Press in the direction of the arrow become hot depending on the energized condition; therefore, do
not touch the solenoid valves.

Common Exhaust Type for Main and Pilot Valve

 Push-turn locking slotted type [Type D]


While pressing, turn in the direction of the arrow.
Caution
Pilot air is exhausted through the main valve body rather than
If it is not turned, it can be operated the same way as the non- directly to atmosphere.
locking type. • Suitable for applications where exhausting the pilot valve to
Locked position atmosphere would be detrimental to the surrounding working
environment.
• For use in extremely dirty environments where there is the
PUSH

LOCK

possibility that dust could enter the pilot exhaust and damage
the valve.
Ensure that the piping of exhaust air is not too restrictive.

Caution
When operating the locking type D with a screw driver, turn it Series SYJ3000/5000/7000
gently using a watchmakers screw driver. Mixed Installation of 3 Port and 5 Port Valves
[Torque: Less than 0.1 N.m]
on Same Manifold.

 Push-turn locking lever type [Type E] Caution


While pressing, turn in the direction of the arrow. Series SYJ3000/5000/7000 and Series SYJ300/500/700 can be
If it is not turned, it can be operated the same way as the non- mounted on the same manifold. How to mount on the same
locking type. manifold is shown on the following pages.
SYJ3000, SYJ300 P. 14
Locked position SYJ5000, SYJ500 P. 38
SYJ7000, SYJ700 P. 61
If 4 or 5 port valve is used as a 3 port valve
PUSH

LOCK

Series SYJ3000, 5000, 7000 may be used as a N.C.or N.O. 3


port valve by plugging one of the A,B ports. Be sure not to plug
the exhaust ports (R). Can be used when a double solenoid, 3
port valve is required.

Caution Plug position B port A port


When locking the manual override on the push-turn locking Type of actuation N.C. N.O.
types (D, E), be sure to push it down before turning. (A) (B) (A) (B)
Number of solenoids

4 2 Plug Plug 4 2
Single

Turning without first pushing it down can cause damage to the


manual override and trouble such as air leakage, etc. 5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
(A) (B) Plug (A) (B)
4 2 Plug 4 2
Double

5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)

(JIS symbols above: Series SYJ5000)

Back page 6
Series SYJ3000/5000/7000
Specific Product Precautions 2
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

How to Use Plug Connector Plug Connector Lead Wire Length

Caution Caution
1. Attaching and detaching connectors Standard length is 300 mm, but the following lengths are also
• To attach a connector, hold the lever and connector unit available.
between your fingers and insert straight onto the pins of the
solenoid valve so that the lever’s pawl is pushed into the
groove and locks. How to Order Connector Assembly
• To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
For DC: SY100 30 4A
connector straight out.
For 100 VAC: SY100 30 1A
Cover
Groove
Pin
For 200 VAC: SY100 30 2A
Cover
Groove
Lever For other voltages of AC: SY100 30 3A
Pin
DC polarity display
Without lead wire: SY100 30 A Lead wire
-+

Socket
(with connector and 2 of sockets only) length
Connector Lead wire
Nil 300 mm
Hook
How to Order 6 600 mm
Include the connector assembly part 10 1000 mm
number together with the part number 15 1500 mm
for the plug connector’s solenoid valve 20
2. Crimping of lead wires and sockets without connector.
2000 mm
25 2500 mm
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the
Ex.) In case of 2000 mm of lead wire 30 3000 mm
ends of the core wires evenly into the sockets, and then crimp
50 5000 mm
with a crimping tool. When this is done, take care that the For DC For AC
coverings of the lead wires do not enter the core wire crimping SYJ3120-5LO-M3 SYJ3120-1LO-M3
area.
SY100-30-4A-20 SY100-30-1A-20
Use an exclusive crimping tool for crimping.
(Contact SMC for special crimping tools.)

Core wire crimping area Crimping area

Socket Core wire


Lead wire 0.2 to 0.33 mm2
Max. Cover diameter: ø1.7 mm

Hook Insulation

3. Attaching and detaching sockets with lead


wires
• Attaching
Insert the sockets into the square holes of the connector (+, –
indication), and continue to push the sockets all the way in
until they lock by hooking into the seats in the connector.
(When they are pushed in, their hooks open and they are
locked automatically.) Then confirm that they are locked by
pulling lightly on the lead wires.
• Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket’s hook with a stick having a thin tip
(approx. 1 mm). If the socket will be used again, first spread
the hook outward.

Socket Connector

Lead wire
Hook

Back page 7
Series SYJ3000/5000/7000
Specific Product Precautions 3
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Surge Voltage Suppressor

Caution
<For DC>
Grommet, L/M Plug Connector DIN Terminal
 Standard type (with polarity) With surge voltage suppressor (DS)
Surge voltage suppressor (S)
Diode to prevent reverse current

Varistor
Red (+) Coil
Coil

Black
With light/surge voltage suppressor (Z) With light/surge voltage suppressor (DZ)
Diode to prevent reverse current

Red (+)

Varistor
Coil Coil

Black
DIN terminal has no polarity.
 Non-polar type
With surge voltage suppressor (R)
(–) (+) M8 Connector
Varistor Coil (Ground)  Standard type (with polarity)
(+) (–) With light/surge voltage suppressor (S)
4
With light/surge voltage suppressor (U) Diode to prevent reverse current
(–) (+)
1 (+)

Varistor Coil
1 3 Coil
(+) (–)
3 (–)
• Connect the standard type in accordance with the +, – Solenoid valve side
polarity indication. (The non-polar type can be used with the pin wiring diagram With light/surge voltage suppressor (Z)
connections made either way.) Diode to prevent reverse current
• Since voltage specifications other than standard 24 V and 12
VDC do not have diodes for polarity protection, be careful 1 (+)

not to make errors in the polarity. Coil


• Please use caution regarding the allowable voltage fluctua-
3 (–)
tion because there is about a 1 volt drop for a valve with po-
larity protection. (For details, refer to the solenoid specifica-
tions for the individual valve.)  Non-polar type
• When wiring is done at the factory, positive (+) is red and (Ground) With surge voltage suppressor (R)
negative (–) is black. 1 (–) (+)
4
 With power saving circuit Electric circuit (with power saving circuit) Varistor Coil

Power consumption is de- Red (+) 3 (+) (–)


Timer circuit

Diode

creased by 1/4 by reducing LED Coil


1 3
the wattage required to hold With light/surge voltage suppressor (U)
the valve in an energized 1 (–) (+)
1 2
state. (Effective energizing Black (–)
1: Starting current 2: Holding current
Solenoid valve side
time is over 62 ms at 24 pin wiring diagram Varistor Coil
VDC.) 3 (+) (–)

Operating Principle • In the case of standard type, connect + to 1 and – to 3


With the above circuit, the current (In the case of the electric
3
SYJ 57 T,
according the polarity.
consumption when holding is re- wave form of energy saving type) • For DC voltages other than 12 V and 24 V, incorrect wiring will
duced to save energy. Please refer Applied voltage case damage to the surge suppressor circuit.
24 V
to the electric wave data to the right. • Please use caution regarding the allowable voltage fluctuation
0V
• Please be careful not to reverse because there is about a 1 volt drop for a valve with polarity
the polarity, since a diode to pre- Standard protection. (For details, refer to the solenoid specifications for
0.4 W
vent the reversed current is not With power
saving circuit the individual valve.)
0.1 W
provided for the power saving cir-
0W
cuit. 62 ms
• Please use caution regarding the
allowable voltage fluctuation because there is about a 0.5
volt drop due to the transistor. (For details, refer to the sol-
enoid specifications for the individual valve.)

Back page 8
Series SYJ3000/5000/7000
Specific Product Precautions 4
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Surge Voltage Suppressor How to Use DIN Terminal


<For AC>
Ground nut
(There is no “S” type because the generation of surge voltage is tightening Set screw
prevented by a rectifier.) torque Tightening
1.65 to 2.5 N•m torque
Grommet, L/M Plug Connector 0.4 N•m
Washer
With light (Z)
( ) Grommet (Rubber) Housing
Varistor

(Rating symbol)
Coil (Light mounting
Refer to table of DIN
connector part no. below. location)
( ) Terminal block
Terminal screw
(3 locations) Notch
DIN Terminal Tightening torque
With light (DZ) ( ) 0.2 to 0.25 N•m
Varistor

Coil

( )
DIN Connector Part No.
NL: Neon light

Note) Surge voltage suppressor of varistor has residual voltage Caution


corresponding to the protective element and rated voltage;
Without light SY100-61-1
therefore, protect the controller side from the surge. The residual
voltage of the diode is approximately 1 V. With light
Rated voltage Voltage symbol Model no.
24 VDC 24 V SY100-61-3-05
How to Use DIN Terminal
12 VDC 12 V SY100-61-3-06
100 VAC 100 V SY100-61-2-01
Caution 200 VAC 200 V SY100-61-2-02
Connection 110 VAC 110 V SY100-61-2-03
1. Loosen the holding screw and pull the connector out of the 220 VAC 220 V SY100-61-2-04
solenoid valve terminal block.
Circuit Diagram with Light
2. After removing the holding screw, insert a flat head screwdriv-
er, etc. into the notch on the bottom of the terminal block and AC circuit DC circuit
pry it open, separating the terminal block and the housing.
3. Loosen the terminal screws (slotted screws) on the terminal
block, insert the cores of the lead wires into the terminals ac-
cording to the connection method, and fasten them securely
with the terminal screws.
4. Secure the cord by fastening the ground nut.
NL : Neon light LED : Light emitting diode
Caution R : Resister R : Resister

When making connections, take note that using other than the Note) Refer to page 80 for DIN connector (Y) conforming to EN-175301-803C (former
DIN 43650C).
supported size (ø3.5 to ø7) heavy duty cord will not satisfy IP65
(enclosure) standards. Also, be sure to tighten the ground nut
and holding screw within their specified torque ranges.

Caution
Changing the entry direction
After separating the terminal block and housing, the cord entry
can be changed by attaching the housing in the desired direction
(4 directions at 90° intervals).
∗ When equipped with a light, be careful not to damage the light
with the cord’s lead wires.

Precautions
Plug in and pull out the connector vertically without tilting to one
side.

Compatible cable
Cord O.D.: ø3.5 to ø7
(Reference) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306

Back page 9
Series SYJ3000/5000/7000
Specific Product Precautions 5
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Connector Assembly with Cover M8 Connector

Caution Caution
Connector assembly with dust proof protective cover. 1. M8 connector types have an IP65 (enclosure) rating, offering
• Effective to prevention of short circuit failure due to the entry of protection from dust and water. However please note: these
foreign matter into the connector. products are not intended for use in water.
• Chloroprene rubber for electrical use, which provides outstand- Select a SMC connector cable (V100-49-1-) or a FA sensor
ing weather resistance and electrical insulation, is used for the type connector, with M8 threaded 3 pin specifications
cover material. However, do not allow contact with cutting oil, conforming to Nippon Electric Control Equipment Association
etc. Standard, NECA4202 (IEC60947-5-2). Make sure the
• Simple and unencumbered appearance by adopting round-shap- connector O.D. is 10.5 mm or less when used with the Series
ed cord. SYJ3000 manifold. If more than 10.5 mm, it cannot be
mounted due to the size.
2. Do not use a tool to mount the connector, as this may cause
damage. Only tighten by hand. (0.4 to 0.6 Nm)
How to Order
3. The excessive stress on the cable connector will not be able to
satisfy the IP65 rating. Please use caution and do not apply a
SY100 68 A stress of 30 N or greater.
Lead wire length
Nil 300 mm Caution
6 600 mm Failure to meet IP65 performance may result if using alternative
10 1000 mm connectors than those shown above, or when insufficiently tight-
15 1500 mm ened.
20 2000 mm
25 2500 mm • Connector cable mounting
30 3000 mm
50 5000 mm
Triangle mark
Arrow mark
Connector Assembly with Cover: Dimensions
(40) Gray

(10)
(8)
(ø4.1)
(6.9)

Red Black
(8)

Note) Connector cable should be mounted in the correct


direction. Make sure that the arrow symbol on the
(14.5) L connector is facing the triangle symbol on the valve
when using SMC connector cable (V100-49-1-). Be
careful not to squeeze it in the wrong direction, as
problems such as pin damage may occur.

 Connector cable
 M8 connector cable for M8 can be ordered as follows:
How to Order
Enter the part number for a plug connector solenoid valve without How to Order
connector together with the part number for a connector assem- 1. To order solenoid valve and connector cable at the same time.
bly with cover. (Connector cable will be included in the shipment of the
Ex. 1) Lead wire length of 2000 mm solenoid valve.)
SYJ3120-5LOZ-M3
SY100-68-A-20 3
Ex. 2) Lead wire length of 300 mm (standard)
SYJ 57
SYJ3120-5LPZ-M3 Electrical entry
W1: Cable length 300 mm
Symbol for connector assembly with cover W2: Cable length 500 mm
W3: Cable length 1000 mm
∗ In this case, the part number for the connector assembly with W4: Cable length 2000 mm
cover is not required. W7: Cable length 5000 mm
Ex. 1) Cable length: 300 mm
SYJ3120-5W1ZE-M3
Symbol for electrical entry

Back page 10
Series SYJ3000/5000/7000
Specific Product Precautions 6
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

M8 Connector Flat Ribbon Cable Manifold


2. To order connector cable only Manifold Internal Wiring
(Ground) Connector dimensions
4 Brown: 1 Blue: 3 Station 12 Station 4 Station 3 Station 2 Station 1
Coil
ø9

3 1
Black: 4

Side A

Side B

Side A

Side B

Side A

Side B

Side A

Side B

Side A

Side B
Triangle mark
33.9

Coil

Coil

Coil

Coil

Coil

Coil

Coil

Coil

Coil

Coil
indicator
position
L 35 10 25 23
7 5 3 1
Note)
26 24
8 6 4 2 Connector
Cable length (L) No.
300 mm V100-49-1-1

(+) (-)
Common (+) (-)

A coil (+) (-)


Side B coil (+) (-)

Side A coil (+) (-)


Side B coil (+) (-)

Side A coil (+) (-)


Side B coil (+) (-)

A coil (+) (-)


Side B coil (+) (-)

A coil (+) (-)


Side B coil (+) (-)
500 mm V100-49-1-2
1000 mm V100-49-1-3

{ Common
2000 mm V100-49-1-4

{ Side

{ Side

{ Side
5000 mm V100-49-1-7

{
Connected
on the Station 12 Station 4 Station 3 Station 2 Station 1
printed board
22 33.9
Max. 12 stations 1
Triangle mark 2
3
Note) 24
Terminal no. is not indicated on the connector. 25
The terminal no. indicated in the connection Reference figure 26
14

schematic of connector, as shown in the


reference, means a correlation of 1, 2, 3····26
from the triangle mark side on the flat ribbon
cable of connector.
Flat Ribbon Cable Manifold
• For more than 10 stations, both poles of the common should be
Caution wired.
• For single solenoid, connect to the solenoid B side.
Type 21P Type 32P • The maximum number of stations that can be accommodated is
12. For more stations, contact SMC.
• Only non-polar valves are available for the DC flat cable
manifold, therefore negative COM or positive COM wiring of the
manifold is possible. The valve does not switch with negative
COM if a Z type is used. Be sure to use a positive COM.

 In the manifold valves, the wiring to the individual valves is Bracket


provided on a printed circuit board, and the connection to the
external wires is consolidated through the use of a flat cable. Caution
 A single MIL flat cable connects the entire manifold to your For bracket attached styles of SYJ3000 (Single) and SYJ7000,
power source. This greatly reduces installation time. do not use it without bracket.

Replacement of Pilot Valve

Caution
Mount it so that there is no slippage or deformation in gaskets,
and tighten with the tightening torque as shown below.
Model Thread size Tightening torque
SYJ3000 M1.7 0.12 N·m
SYJ5000 M2.5 0.45 N·m
SYJ7000 M3 0.8 N·m

Back page 11
Series SYJ3000/5000/7000
Specific Product Precautions 7
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Replacement of Pilot Valve Interface Regulator

Caution Note 1) Set the pressure within the operating pressure range of
the solenoid valve.
Pilot valves in this series are improved to provide excellent energy Note 2) The maximum operating temperature for the solenoid
saving results. However following this improvement, these new valve is 50°C.
valves are no longer compatible with the conventional pilot valve Note 3) The effective area listed is for a single solenoid 2 position
used at the interface. Consult with SMC when you need to valve mounted on a sub-plate.
exchange these pilot valves, in the case of manual override Note 4) Apply pressure from P port in the base for interface
(marked in orange) of the adapter plate. regulator.
New type Manual override
(Blue) Flow Characteristics
(P → A) Condition: Inlet pressure 0.7 MPa
-+

B
A

ARBYJ5000-00-P
Interface
0.6

0.5
Pilot valve
(V111)
Outlet pressure (MPa)

Adapter plate
0.4
Conventional type
Manual override
0.3
(Orange)
-+

B
A

0.2
Interface
0.1

0
0 50 100 150 200
Pilot valve
(SY114) Adapter plate Flow rate l/min (ANR)

ARBYJ7000-00-P
Interface Regulator
0.6
Caution
0.5
Outlet pressure (MPa)

Spacer type regulating valve 0.4


on manifold block can
regulate the pressure to the
valve individually. 0.3

Specifications 0.2
Interface regulator ARBYJ5000 ARBYJ7000

Applicable solenoid valve model SYJ5000 SYJ7000 0.1

Regulating port P P
0
Proof pressure 1.5 MPa 0 100 200 300 400
Flow rate l/min (ANR)
Maximum operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa Note 1)
Ambient and fluid temperature -5 to 60°C (No freezing) Note 2)
Thread size for connection of pressure gauge M5 x 0.8
Weight (kg) 0.06 0.09
Effective area at exhaust Note 3) P→A 1.9 5.1
side (mm2)
S at P1 = 0.7 MPa, P2 = 0.5 MPa P→B 2.1 5.8
Effective area at supply Note 3)
A → EA 4.5 12.6
side (mm2)
S at P1 = 0.7 MPa, P2 = 0.5 MPa B → EB 4.5 12.6

Back page 12
SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK

EUROPE POLAND SOUTH KOREA


AUSTRIA SMC Industrial Automation Polska Sp.z.o.o. SMC Pneumatics Korea Co., Ltd.
SMC Pneumatik GmbH ROMANIA TAIWAN
BELGIUM SMC Romania s.r.l. SMC Pneumatics (Taiwan) Co., Ltd.
SMC Pneumatics N.V./S.A. RUSSIA THAILAND
BULGARIA SMC Pneumatik LLC. SMC Thailand Ltd.
SMC Industrial Automation Bulgaria EOOD SLOVAKIA
CROATIA SMC Priemyselná automatizáciá, s.r.o. NORTH AMERICA
SMC Industrijska automatika d.o.o. SLOVENIA CANADA
CZECH REPUBLIC SMC INDUSTRIJSKA AVTOMATIKA d.o.o. SMC Pneumatics (Canada) Ltd.
SMC Industrial Automation CZ s.r.o. SPAIN/PORTUGAL MEXICO
DENMARK SMC España, S.A. SMC Corporation (Mexico) S.A. de C.V.
SMC Pneumatik A/S SWEDEN USA
ESTONIA SMC Pneumatics Sweden AB SMC Corporation of America
SMC Pneumatics Estonia OÜ SWITZERLAND
FINLAND SMC Pneumatik AG. SOUTH AMERICA
SMC Pneumatics Finland OY UK ARGENTINA
FRANCE SMC Pneumatics (U.K.) Ltd. SMC Argentina S.A.
SMC Pneumatique SA BOLIVIA
GERMANY ASIA SMC Pneumatics Bolivia S.R.L.
SMC Pneumatik GmbH CHINA BRAZIL
HUNGARY SMC (China) Co., Ltd. SMC Pneumaticos Do Brazil Ltda.
SMC Hungary Ipari Automatizálási Kft. HONG KONG CHILE
IRELAND SMC Pneumatics (Hong Kong) Ltd. SMC Pneumatics (Chile) S.A.
SMC Pneumatics (Ireland) Ltd. INDIA VENEZUELA
ITALY SMC Pneumatics (India) Pvt. Ltd. SMC Neumatica Venezuela S.A.
SMC Italia S.p.A. INDONESIA
LATVIA PT. SMC Pneumatics Indonesia OCEANIA
SMC Pnuematics Latvia SIA MALAYSIA AUSTRALIA
NETHERLANDS SMC Pneumatics (S.E.A.) Sdn. Bhd. SMC Pneumatics (Australia) Pty. Ltd.
SMC Pneumatics BV. PHILIPPINES NEW ZEALAND
NORWAY SHOKETSU-SMC Corporation SMC Pneumatics (N.Z.) Ltd.
SMC Pneumatics Norway A/S SINGAPORE
SMC Pneumatics (S.E.A.) Pte. Ltd.

1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN


Tel: 03-3502-2740 Fax: 03-3508-2480
URL http://www.smcworld.com
© 2005 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice D-DN 1st printing IO printing JP 120DN Printed in Japan.
and any obligation on the part of the manufacturer. This catalog is printed on recycled paper with concern for the global environment.
Series 10-SYJ3000/5000/7000 Rubber seal
4/5 port solenoid valve

Variations
Option
Sonic conductance Type of Manual
Series Voltage Electrical entry
C[dm3/(s·bar)] actuation Light/Surge override
voltage suppresser

10-SYJ3000 For DC For DC


Effective area
0.9mm2
4/2→5/3 왎 24 VDC Grommet 왎 With surge
(A/B→EA/EB) 12 VDC voltage suppresser
6 VDC
P.494 5 VDC –+
3 VDC
Body ported

10-SYJ5000
0.47 왎 With light/surge
L plug connector voltage suppressor
4/2→5/3
(A/B→EA/EB) }
P.515

+

10-SYJ7000 For AC
2.4 2 position M plug connector
4/2→5/3
(A/B→EA/EB) } · Single
· Double
왎AC 100V / Hz
50
60

AC 110V 50
/ Hz60

AC 200V 50
/ Hz60 +–

P.537 AC 220V 50
/ Hz60
왎 Non-locking
push type
10-SYJ3000
3 position
0.46
· Closed center
4/2→5/3
(A/B→EA/EB) } · Exhaust center
· Pressure center
왎 Push-turn
Base mounted type

P.494 For AC Note) locking slotted


DIN terminal type
왎 With light/surge
10-SYJ5000
voltage suppresser
0.83
왎 Push-turn
4/2→5/3
(A/B→EA/EB) } locking
lever type
(10-SYJ5000/7000
only)
P.515

10-SYJ7000 M8 connector

2.9
4/2→5/3
(A/B→EA/EB) }
P.537
Note) All standard AC voltage models have built-in surge voltage suppresser.

492
4/5 port solenoid valve Series 10-SYJ3000/5000/7000

Manifold variations
A, B port size Manifold option

One-touch fitting

Air cylinder
A, B port Flat ribbon cable manifold
Valve series Individual Individual
location M3 M5 1/8 Applicable tubing O.D. SUP spacer EXH spacer
assembly assembly
ø4 ø6 ø8 N3 N7 N9

10-SYJ3000 앬 — — — — — — — — — — 앬
Body ported

Rotary actuator
10-SYJ5000 Top — 앬 — 앬 앬 — 앬 앬 — 앬 앬 앬

10-SYJ7000 — — 앬 — 앬 앬 — 앬 앬 — 앬 앬

Side 앬 앬 — 앬 — — 앬 — — 앬

Air gripper
10-SYJ3000 — —
Bottom — — — — — — — — — —
Base mounted

Side — 앬 — 앬 앬 — 앬 앬 — 앬

Directional control
10-SYJ5000 앬 앬

valve
Bottom — — — — — — — — —

Side — — 앬 — 앬 앬 — 앬 앬 —
10-SYJ7000 앬 앬
Bottom — — 앬 — — — — — —

Flow control

equipment
Body ported Type 21P
A, B port

P port

control equipment
Filter, Pressure
Individual SUP
R port spacer assembly
Base mounted
P port

P
Type 32P

Fittings & Tubing


R port
A, B port

R port
A, B port
P port
Air preparation
equipment

Mixed mounting of 3 port valves and 4, 5 port valves

Individual EXH 4/5 port valve


3 port valve
R port spacer assembly
A, B port R2
P port
Pressure switch

R1

R port
· For detailed specifications about 10-
A, B port SYJ3000, refer to page 507. For 10-
P port SYJ5000, refer to page 529, and for
10-SYJ7000, refer to page 550.
Clean gas filter

493
Series 10-SYJ3000 Rubber seal
4/5 port solenoid valve

Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure range (MPa) 2 position double 0.1 to 0.7
3 position 0.2 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (with no freezing. Refer to page 714.)
Response time ms 2 position single, double 15 or less
(0.5MPa) Note 1) 3 position 30 or less
2 position single, double 10
Max. operating frequency (Hz)
3 position 3
Body ported Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
2 Note 2)
Shock/Vibration resistance m/s 150/30
Enclosure Dustproof (∗ M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature : 20°C, at rated voltage and
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000Hz. Test
was performed to axis and right angle directions of the main valve when pilot signal is ON and
Base mounted OFF. (Value in the initial state)

Solenoid specifications
JIS Symbol
5 port 4 port (For manifold
use only) Electrical entry Grommet (G)/(H), L plug connector (L),
2 position single 2 position single M plug connector (M), M8 connector (W)
(B) (A) (B)(A)
2 4 2 4 DC 24, 12, 6, 5, 3
Coil rated voltage V
AC50/60Hz 100, 110, 200, 220
3 1 5
(R) (P) (R)
1 3 Allowable voltage fluctuation ±10% of rated voltage ∗
(P) (R)
2 position double 2 position double Standard 0.35 (With indicator light: 0.4)
(B) (A) (B) (A) Power consumption (W) DC
2 4 2 4 With power saving circuit 0.1 (With indicator light only)
100 VAC 0.78 (With indicator light: 0.81)
3 1 5 110 VAC 0.86 (With indicator light: 0.89)
(R) (P) (R) 1 3
(P) (R)
Apparent power (VA) ∗ [115 VAC] [0.94(With indicator light: 0.97)]
3 position closed center 3 position closed center AC
(B) (A) (B) (A) 200 VAC 1.18 (With indicator light: 1.22)
2 4 2 4
220 VAC 1.30 (With indicator light: 1.34)
3 1 5 [230 VAC] [1.42 (With indicator light: 1.46)]
(R) (P) (R) 1 3
(P) (R) Surge voltage suppressor Diode (Non-polar type: Varistor)
3 position exhaust center 3 position exhaust center Indicator light LED
(B)(A) (B) (A)
2 4 2 4
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is -15% to +5% of rated voltage.
3 1 5
(R) (P) (R) 1 3 ∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please
(P) (R) observe the following range because they have voltage drop due to internal circuit.
3 position pressure center 3 position pressure center
(B) (A) (B) (A) S and Z types 24 VDC: -7% to +10% 12 VDC: -4% to +10%
2 4 2 4 T type 24 VDC: -8% to +10% 12 VDC: -6% to +10%

3 1 5
Bracket mounting
(R) (P)(R) 1 3
(P) (R) (1) Insert the lower hook of the mounting (2) Press the valve and mounting bracket
bracket into the groove on the bottom of together until the upper hook of the bracket
the valve as shown. snaps into place in the groove on top of the
Made to valve.
Order Made to order specifications
(Refer to page 557 for details.)

494
4/5 port solenoid valve Series 10-SYJ3000
Flow characteristics / Weight
Port size Weight (g) Note 3, 4) Flow characteristics Note 2)
Effective
Valve model Type of actuation 1, 5, 3 4, 2 L/M plug M8 area mm 2 1→4/2(P→A/B) 4/2→5/3(A/B→EA/EB)
Grommet

Air cylinder
(P, EA, EB) (A, B) connector Connector C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv
10-SYJ3143 2 Single 62(36) 63(37) 67(41) —
0.46 0.36 0.12 0.46 0.35 0.12
5 port base 10-SYJ3243 position Double 79(53) 81(55) 89(63)
mounted 10-SYJ3343 Closed center M5 x 0.8 M5 x 0.8 — 0.47 0.33 0.12 0.47 0.31 0.12
(With sub-plate) 10-SYJ3443 3 Exhaust center 82(56) 84(58) 92(66) — 0.36 0.39 0.10 0.59[0.40] 0.43[0.33] 0.16[0.11]
position
10-SYJ3543 Pressure center — 0.58[0.32] 0.42[0.33] 0.16[0.080] 0.46 0.32 0.11
10-SYJ3123 2 Single 36 37 41

Rotary actuator
10-SYJ3223 position Double 53 55 63
5 port
10-SYJ3323 Closed center M3 x 0.5 M3 x 0.5 0.9
body ported 3
10-SYJ3423
position
Exhaust center 56 58 66
10-SYJ3523 Pressure center
10-SYJ3133 2 Single 36 37 41 —
4 port base 10-SYJ3233 position Double 53 55 63
mounted
10-SYJ3333 Closed center 1/8 M5 x 0.8 —
(For manifold 3
base only)Note 1) 10-SYJ3433 position Exhaust center 56 58 66 —

Air gripper
10-SYJ3533 Pressure center —
Note 1) Dedicated for manifold base, refer to page 11 for details.
Note 2) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 3) ( ): Without sub-plate
Note 4) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the
weight of the double solenoid and 3 position types.

Directional control
valve
Flow control
equipment
control equipment
Filter, Pressure
Fittings & Tubing
Air preparation
equipment
Pressure switch
Clean gas filter

495
4/5 port solenoid valve Series SYJ3000

How to Order
Light/surge voltage suppressor Bracket
Type of actuation Nil Without light/surge voltage suppressor Nil: Without bracket F: With bracket
1 2 position single solenoid S With surge voltage suppressor
2 2 position double solenoid Z With light/surge voltage suppressor
3 3 position closed center R With surge voltage suppressor (Non-polar type)
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
5 3 position pressure center
∗ For AC voltage valves, there is no "S" option. It is -+

already built-in to the rectifier circuit.


∗ For "R" and "U", DC voltage is only available. Single Double
∗ Power saving circuit is only available in the "Z" type. (Bracket cannot be retrofitted.)

5 port Rated voltage Note) The double solenoid mounting bracket is supplied
unattached.
DC AC (50/60Hz) To order the double solenoid bracket for use with a
5 24 VDC 1 100 VAC single solenoid valve, order the single solenoid
valve without a bracket and double solenoid
6 12 VDC 2 200 VAC
bracket separately by specifying the part number
V 6 VDC 3 110 VAC [115 VAC] of the bracket VJ3000-13-1besides the part
S 5 VDC 4 220 VAC [230 VAC] number of the solenoid valve.
∗ For type "W첸", DC voltage [Example] 10-SYJ3123-5M-M3
R 3 VDC
(Type 20 manifold) is only available. VJ3000-13-1

Body ported 10 SYJ3 1 23 5 M M3


Base mounted
(4 port) 10 SYJ3 2 33 5 M (Manifold use only)
Base mounted
(5 port) 10 SYJ3 2 43 5 M
4 port Clean series Coil specifications Manual override Port size
Nil Standard
Nil: Non-locking push type Nil: Without sub-plate
With power saving circuit
T
<24, 12 VDC only>
∗ Power saving circuit is
not available in the case
For manifold of "W첸" type.
type 31, S31, 32, S32
5 port
(With gasket and screws)
D: Push-turn locking
slotted type M5: With M5 port sub-plate

For sub-plate, manifold


type 41, S41, 46, S46

Electrical entry
24, 12, 6, 5, 3 VDC 24, 12 VDC
100, 110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector M8 connector E: Push-turn locking lever type
G: Lead wire L: With lead M: With lead wire MN: Without WO: Without connector
length wire (length (length 300 mm) lead wire cable
300 mm 300 mm)

+– +–

–+
–+

H: Lead wire LN: Without LO: Without MO: Without W첸: With connector
length lead wire connector connector cable Note 1)
600 mm

–+
–+

Note) When placing an order for body ported


solenoid valve as a single unit, mounting
bolt for manifold and gasket are not
∗ "LN", "MN" types: with 2 sockets. attached. Order them separately, if
∗ For connector cable of M8 connector, refer to page 562. necessary.
Note 1) Be sure to enter a symbol of the cable length in 첸 with reference to P562. (Refer to catalog page 508 for details.)
496
4/5 port solenoid valve Series 10-SYJ3000

How to Order Pilot Valve Assembly How to Order Connector Assembly for L/M Plug Connector

Air cylinder
10 V111 5 G For DC : SY100-30-4A-
Clean series
Light/Surge voltage suppressor
For 100 VAC : SY100-30-1A-
Nil Without light/surge voltage suppressor
Coil specifications S With surge voltage suppresser For 200 VAC : SY100-30-2A-

Rotary actuator
Nil Standard Z With light/surge voltage suppresser
R
T
With power saving circuit
<24, 12 VDC only> U
With surge voltage suppressor (Non-polar type)
With light/surge voltage suppressor (Non-polar type)
For other voltages of AC : SY100-30-3A-
∗ Power saving circuit ∗ For AC voltage valves, there is Without lead wire
is not available in
the case of "W첸"
no "S" option. It is already built-
in to the rectifier circuit.
(With connector and 2 of sockets only) : SY100-30-A
type. ∗ For "R" and "U", DC voltage is
only available. Lead wire length
∗ Power saving circuit is only available Nil 300mm

Air gripper
in the "Z" type. 6 600mm
10 1000mm
Rated voltage Electrical entry 15 1500mm
5 24 VDC G Grommet (Lead wire length 300 mm) 20 2000mm
6 12 VDC H Grommet (Lead wire length 600 mm) 25 2500mm
V 6 VDC L With lead wire 30 3000mm
S 5 VDC L plug 50 5000mm
LN connector Without lead wire

Directional control
R 3 VDC
1 100 VAC50/60Hz LO Without connector
2 200 VAC50/60Hz M With lead wire

valve
M plug
3
110 VAC50/60Hz
[115 VAC50/60Hz]
MN connector Without lead wire How to Order M8 Connector Cable
MO Without connector
220 VAC50/60Hz WO M8 Without connector cable
4
[230 VAC50/60Hz] W첸 Connector With connector cable Note 1) V100-49-1-
∗ For type "W첸", DC ∗ For connector cable of M8 connector,
voltage is only avail- refer to page 562.
Cable length

Flow control
equipment
able. Note 1) Be sure to enter a symbol of the
cable length in 첸 with reference 1 300mm
to page 562. 2 500mm
3 1000mm
4 2000mm
7 5000mm

control equipment
Filter, Pressure
Fittings & Tubing
Air preparation
equipment
Pressure switch
Clean gas filter

497
4/5 port solenoid valve Series 10-SYJ3000

2 position single ∗[ ]: AC

Grommet (G), (H): 10-SYJ3123-첸 GH 첸첸-M3 With bracket: 10-SYJ3123-첸 GH 첸첸-M3-F

G: Approx. 300
54.4[56.6] H: Approx. 600
(Lead wire length) 28.4
32.2 2-ø3.5 22 3.2
(For mounting)
13.2 7.1

16.4
10
- +
8.2
4

A B

11.5 19.3
7 Manual override
34.7[41.7]
M3 x 0.5 2-ø1.8
(A, B port) (For manifold mounting) (Light/surge voltage suppressor)

28[35]
-+
22.1

13.5

12.6

54.4[56.6]
15

2
R P R (Bracket) 15
11
10

22.1
7 7
15 M3 x 0.5
(P, R port)

L plug connector (L): M plug connector (M): M8 Connector (WO):


10-SYJ3123-첸L첸첸-M3 (-F) 10-SYJ3123-첸M첸첸-M3 (-F) 10-SYJ3123-첸WO첸첸-M3 (-F)
(Lead wire length)
Approx. 300

28[35]

12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
64.3[66.5]

54.5[56.7]

63.4
56
49.5
(2)

(2)
(2)

13.5 13.5 13.5


15 15 15
22.1 22.1 22.1

∗ Refer to page 563 for dimensions with connector cable.

498
4/5 port solenoid valve Series 10-SYJ3000

2 position double ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ3223-첸 H 첸첸-M3 (-F)

Air cylinder
G: Approx. 300
78.8[83.2] H: Approx. 600
34.4 (Lead wire length)

7.1
1.8

Rotary actuator
4
8.2 A B

M3 x 0.5 7 Manual override


(A, B port)
2-ø1.8
(For manifold mounting)

Air gripper
Equivalent to 2-ø3.2 Bracket (Light/surge voltage suppressor)
(For mounting) (18.5)

28[35]
(18.5)
22.1

-+

13.5

12.6
15

Directional control
valve
(11.5)
10 0.5

R P R

14

Flow control
equipment
M3 x 0.5
(P, R port)

control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 connector (WO):
10-SYJ3223-첸L첸첸-M3 (-F) 10-SYJ3223-첸M첸첸-M3 (-F) 10-SYJ3223-첸WO첸첸-M3 (-F)
(Lead wire length)
Approx. 300

28[35]

Fittings & Tubing


12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
Air preparation
equipment

13.5 13.5 13.5


98.6[103]

79[83.4]

96.8
69

82

Pressure switch

15
22.1 15
15
22.1
22.1
Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

499
4/5 port solenoid valve Series 10-SYJ3000

3 position closed center / exhaust center / pressure center ∗ [ ]: AC

3
Grommet (G), (H): 10-SYJ3 45 23-첸GH첸첸-M3 (-F)

G: Approx. 300
91.7[96.1] H: Approx. 600
40.2[42.4] (Lead wire length)
29.3 18
1.8 5.3

4
8.2

A B

M3 x 0.5 7 Manual override


(A, B port) 2-ø1.8
(For manifold mounting)

Equivalent to 2-ø3.2 Bracket (Light/surge voltage suppressor)


(For mounting) (18.5)

28[35]
(18.5)
22.1

-+

13.5

12.6
15

(11.5)
10 0.5

R P R

14

M3 x 0.5
(P, R port)

L plug connector (L): M plug connector (M): M8 Connector (WO):


3 3 3
10-SYJ3 45 23-첸L첸첸-M3 (-F) 10-SYJ3 45 23-첸M첸첸-M3 (-F) 10-SYJ3 45 23-첸WO첸첸-M3 (-F)
(Lead wire length)
Approx. 300

28[35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
50.1[52.3]

40.3[42.5]

49.2
41.8
35.3

13.5 13.5 13.5


111.5[115.9]

91.9[96.3]

109.7
46.6

53.1

15
22.1 15
15
22.1
22.1

∗ Refer to page 563 for dimensions with connector cable.

500
4/5 port solenoid valve Series 10-SYJ3000

2 position single ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ3143-첸 H 첸첸-M5

Air cylinder
M5 x 0.8 10
(A, B port)

5
10

Rotary actuator
2-ø3.2 32.2
(For mounting)
22 4

2.5
Manual override
B A

11
A
B

Air gripper
G: Approx. 300 1
H: Approx. 600 54.4[56.6]
(Light/surge voltage suppressor) (Lead wire length)

Directional control
41.5[48.5]

-+

35.6

valve
28.5
26.1

R2 P R1
13

10 10 10 M5 x 0.8
17.5 (Mounting hole)
14
28

Flow control
equipment
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 Connector (WO):
10-SYJ3143-첸L첸첸-M5 10-SYJ3143-첸M첸첸-M5 10-SYJ3143-첸WO첸첸-M5
(Lead wire length)

Fittings & Tubing


Approx. 300

41.5[48.5]
26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
Air preparation
equipment
64.3[66.5]

54.5[56.7]

63.4
56
49.5
R2

R2

R2
10 10

10 10

10 10
28

28

28
P

P
14

14

14
R1

R1

R1

Pressure switch

5 5 5
28.5 28.5 28.5
35.6 35.6 35.6
Clean gas filter

∗ Refer to page 563 for dimensions


with connector cable.

501
4/5 port solenoid valve Series 10-SYJ3000

2 position double ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ3243-첸 H 첸첸-M5

M5 x 0.8 10
(A, B port)

5
10
2-ø3.2
(For mounting) 22

2.5
Manual override

11
G: Approx. 300 34.4
H: Approx. 600 78.8[83.2]
(Light/surge voltage suppressor) (Lead wire length)
41.5[48.5]

35.6
26.1
13

10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)
28

L plug connector (L): M plug connector (M): M8 connector (WO):


10-SYJ3243-첸L첸첸-M5 10-SYJ3243-첸M첸첸-M5 10-SYJ3243-첸WO첸첸-M5
(Lead wire length)
Approx. 300

41.5[48.5]
26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
98.6[103]

79[83.4]
10 10

10 10

10 10

96.8
28

28

69

28

82
14

14

14

5 5 5

∗ Refer to page 563 for dimensions


with connector cable.

502
4/5 port solenoid valve Series 10-SYJ3000

3 position closed center / Exhaust center / Pressure center ∗ [ ]: AC


3
Grommet (G), (H): 10- SYJ3 45 43-첸 GH 첸첸-M5

Air cylinder
M5 x 0.8
10 (A, B port)

5
10

Rotary actuator
2-ø3.2 32 15.3
(For mounting)
22 3

2.5
Manual override
B A

11

Air gripper
A
B
37.5[39.7]
G: Approx. 300
H: Approx. 600 91.7[96.1]
(Lead wire length)
(Light/surge voltage suppressor)

Directional control
41.5[48.5]

-+

valve
35.6
26.1

R2 P R1
13

10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)

Flow control
equipment
28

control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 Connector (WO):
3 3 3
10-SYJ3 45 43-첸L첸첸-M5 10-SYJ3 45 43-첸M첸첸-M5 10-SYJ3 45 43-첸WO첸첸-M5첸
(Lead wire length)
Approx. 300

41.5[48.5]

Fittings & Tubing


26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
Air preparation
equipment
55.8
49.3
111.5[115.9]
R2

R2

R2
91.9[96.3]
10 10

10 10

10 10
28

28

28

109.7
P

P
14

14

14
R1

R1

R1

5 5 5
37.6[39.8]
47.4[49.6]

32.6

Pressure switch
39.1
46.5

Clean gas filter

∗ Refer to page 563 for dimensions


with connector cable.

503
Series 10-SYJ3000 Manifold specifications

Manifold standard

Manifold specifications

Model Type 20 Type 31/S31 Type 32/S32 Type 41/S41 Type 46/S46

Manifold type Single base / B mount

Common SUP / Common EXH Common SUP /


P (SUP) / R (EXH) Individual EXH
Valve stations 2 to 20 stations
A, B port porting Location Valve Base
specifications Direction Top Side

P, R port M5 x 0.8 1/8 P: 1/8


Port size R: M5 x 0.8
A, B port M3 x 0.5 M5 X 0.8, C4 (One-touch fitting for ø4)

Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R) Effective
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C (mm2)
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
Body ported for
10-SS5YJ3-20 10-SYJ3첸23 M5 x 0.8 M3 x 0.5 — — — — — — 0.9
internal pilot
10-SS5YJ3-31-S31 10-SYJ3첸33 M5 x 0.8 M3 x 0.5 — — — — — — 0.9
10-SS5YJ3-32-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 —
10-SS5YJ3-32-C4 C4 0.25 0.18 0.059 0.30 0.27 0.075 —
10-SYJ3첸33 1/8
10-SS5YJ3-S32-M5 M5 x 0.8 0.25 0.26 0.060 0.29 0.15 0.062 —
10-SS5YJ3-S32-C4 C4 0.24 0.21 0.057 0.27 0.18 0.062 —
Base mounted for 10-SS5YJ3-41-M5 M5 x 0.8 0.32 0.25 0.081 0.33 0.19 0.079 —
internal pilot 10-SS5YJ3-41-C4 C4 0.32 0.28 0.079 0.35 0.24 0.084 —
10-SYJ3첸43 1/8
10-SS5YJ3-S41-M5 M5 x 0.8 0.33 0.29 0.082 0.34 0.17 0.081 —
10-SS5YJ3-S41-C4 C4 0.32 0.27 0.079 0.34 0.24 0.084 —
10-SS5YJ3-46-M5 M5 x 0.8 0.20 0.25 0.048 0.10 0.12 0.024 —
10-SS5YJ3-46-C4 1/8 C4 0.21 0.27 0.050 0.21 0.13 0.047 —
10-SYJ3첸43
10-SS5YJ3-S46-M5 M5 x 0.8 M5 x 0.8 0.20 0.25 0.048 0.19 0.16 0.024 —
10-SS5YJ3-S46-C4 C4 0.22 0.34 0.057 0.10 0.090 0.024 —
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model no.
Example
앬10-SS5YJ3-20-03 ······ 1 set (Manifold base) 앬10-SS5YJ3-S41-03-C4 ······ 1 set (Manifold base)
∗ 10-SYJ3123-5G-M3 ······ 2 sets (Valve) ∗ 10-SYJ3143-5LZ ······ 2 sets (Valve)
∗ SYJ3000-21-1A······ 1 set (Blanking plate assembly) ∗ SYJ3000-21-2A ······ 1 set (Blanking plate assembly)

The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

504
Manifold specifications 10-SYJ3000

Flat ribbon cable manifold


• Multiple valve wiring is Flat ribbon cable manifold specifications
simplified through the

Air cylinder
Model Type 21P Type 32P
use of the flat ribbon Manifold Single base / B mount
cable connector. P(SUP) / R(EXH) Common SUP / Common EXH
Valve stations 4 to 12 stations
• Clean appearance A, B port piping Location Valve Base
specifications Direction Top Side

Rotary actuator
In the case of a flat ribbon cable type, each valve
is wired on the print board of manifold base to P, R port 1/8
allow the external wiring to be piped all together Port size
A, B port M3 x 0.5 M5 x 0.8 C4 (One-touch fitting for ø4)
with 26 pins MIL connector.
Applicable flat ribbon
cable connector Socket: 26 pins MIL type with strain relief (conforming to MIL-C-83503)

Internal wiring In common between +COM and –COM (Z type: +COM only).
Rated voltage 12, 24 VDC, 100, 110 VAC
Note) The withstand voltage specification for the wiring unit section conforms to JIS C0704, Grade 1 or

Air gripper
its equivalent.

Flow characteristics

Directional control
Type 21P Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R) Effective

valve
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C (mm2)
port b Cv b Cv
port [dm /(s·bar)]
3 [dm /(s·bar)]
3

Body ported
for internal pilot
10-SS5YJ3-21P 10-SYJ3첸23 1/8 M3 x 0.5 — — — — — — 0.9

Base mounted 10-SS5YJ3-32P-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 —
for internal pilot 10-SS5YJ3-32P-C4
10-SYJ3첸33 1/8
C4 0.25 0.18 0.059 0.3 0.27 0.075 —

Flow control
equipment
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifolds


앬10-SS5YJ3-32P-07-C4 ··1 set (Manifold base) ∗ SYJ3000-21-4A ··1set (Blanking plate assembly)

control equipment
∗ 10-SYJ3133-5LOU ····3 sets (Valve) ∗ SY3000-37-28A ··3 sets (Connector assembly)

Filter, Pressure
∗ 10-SYJ3233-5LOU ····3 sets (Valve) ∗ SY3000-37-29A ··3 sets (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

How to Order Connector


How to Order Valves Assemblies

Fittings & Tubing


Light/Surge voltage suppressor
Rated voltage Z With light/surge voltage suppressor For 12, 24 VDC
5 24 VDC With light/surge voltage
U For single solenoid SY3000-37-28A
6 12 VDC suppressor (Non-polar type)
Double solenoid 3
Clean series Note) Z: Positive common specifications only.
position type
SY3000-37-29A

2
Air preparation

For DC10 SYJ3 1 3 5 LO U


equipment

3 For 100 VAC


For single solenoid SY3000-37-46A
2
For AC10 SYJ3 1 3 3 1 LO Z Double solenoid 3
position type
SY3000-37-47A
Type of actuation
1 2 position single A, B port size
Pressure switch

2 2 position double Symbol Port size 110 VAC (115 VAC)


3 3 position closed center Nil Base mounted For single solenoid SY3000-37-54A
4 3 position exhaust center M3 M3 x 0.5 Double solenoid 3
3 position pressure center SY3000-37-55A
5 position type
Rated voltage
1 100 VAC Note) In the case of flat ribbon cable type,
3 110 VAC(115 VAC) "U" and "Z" types are for DC
Clean gas filter

specifications and "Z" type is for AC


Manual override specifications. "Z" type for DC is
positive common specifications
Nil Non-locking push type
only. For other combinations,
D Push-turn locking slotted type please contact SMC.
E Push-turn locking lever type

505
Manifold specifications 10-SYJ3000

Common SUP / Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20 (5 port / Body ported) How to Order Applicable solenoid valve


10-SYJ3첸23-첸첸첸첸-M3
A, B port 10--SS5YJ3--20-- 05
M3 x 0.5 Applicable blanking plate
Clean series assembly
Stations SYJ3000-21-1A
02 2 stations

P port : :
R port
M5 x 0.8 M5 x 0.8 20 20 stations

Type 31 (4 port / Base mounted) How to Order Applicable solenoid valve


10-SYJ3첸33-첸첸첸첸
Type S31 Single solenoid coil is located on
(the same side of A and B ports. ) 10--SS5YJ3--
Type 31 31-- 05 --M3 Applicable blanking plate
Clean series assembly
SYJ3000-21-2A
Valve mounting direction
Manifold stations
R port Single solenoid coil is located on 02 2 stations
R port Nil
M5 x 0.8 A, B port the opposite side of A and B ports.
M5 x 0.8 : :
A, B port M3 x 0.5 P port Single solenoid coil is located on
P port S 20 20 stations
M3 x 0.5 the same side of A and B ports.
M5 x 0.8
M5 x 0.8

Type 32 (4 port / Base mounted) How to Order

Type 32 Type S32 10--SS5YJ3-- 32-- 05 -- M5


(Single solenoid coil is located on
the same side of A and B ports. ) Clean series
Manifold stations
P, R port thread type
Valve mounting direction 02 2 stations
Single solenoid coil is located on Nil Rc
Nil : :
the opposite side of A and B ports. F G
20 20 stations
Single solenoid coil is located on N NPT
R port R port S A, B port size
the same side of A and B ports.
1/8 1/8 T NPTF
A, B port M5 M5 x 0.8
A, B port P port P port
M5 x 0.8, C4 1/8 C4 One-touch fitting for ø4
M5 x 0.8, C4 1/8
N3 One-touch fitting for ø5/32"

Type 41 (5 port / Base mounted) How to Order Applicable solenoid valve


10-SYJ3첸43-첸첸첸첸
Type 41 Type S41
10--SS5YJ3-- 41-- 05 -- C4 Applicable blanking
Single solenoid coil is located on
( the same side of A and B ports. ) Clean series
Manifold stations
plate assembly
R port SYJ3000-21-2 A
1/8 P port
Valve mounting direction 02 2 stations
1/8 Single solenoid coil is located on : :
Nil
the opposite side of A and B ports.
20 20 stations
Single solenoid coil is located on P, R port thread type
S
the same side of A and B ports. A, B port size Nil Rc
P port
1/8 R port M5 M5 x 0.8 F G
A, B port 1/8 C4 One-touch fitting for ø4
A, B port N NPT
M5 x 0.8, C4 M5 x 0.8, C4 N3 One-touch fitting for ø5/32" T NPTF

Common SUP / Individual EXH Note) For more than 10 stations, supply air to both sides of P port.

Type 46 (5 port / Base mounted) How to Order Applicable solenoid valve


10-SYJ3첸43-첸첸첸첸
Type 46 Type S46 10--SS5YJ3-- 46-- 05 -- M5
Single solenoid coil is located on Applicable blanking
( the same side of A and B ports. ) Clean series
plate assembly
R1, R2 port Manifold stations SYJ3000-21-2A
M5 x 0.8 Valve mounting direction 02 2 stations
Single solenoid coil is located on : :
Nil P port thread type
the opposite side of A and B ports.
R1, R2 port 20 20 stations
Single solenoid coil is located on Nil Rc
M5 x 0.8 S A, B port size
P
the same side of A and B ports. F G
A

B
A, B port M5 M5 x 0.8
A, B port P port N NPT
M5 x 0.8, C4
M5 x 0.8, C4 1/8 C4 One-touch fitting for ø4 T NPTF
P port
N3 One-touch fitting for ø5/32"
1/8

506
Manifold specifications 10-SYJ3000

Flat ribbon cable manifold

Common SUP / Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Air cylinder
Applicable solenoid valve
Type 21P How to Order
Refer to page 505.
A, B port
M3 x 0.5 10--SS5YJ3--21P-- 07 -- Applicable connector
P, R port assembly
Clean series thread type Refer to page 505.
Manifold stations

Rotary actuator
Nil Rc Applicable blanking
04 4 stations
00F G plate assembly
: :
P port
R port
00N NPT SYJ3000-21-3A
12 12 stations
1/8 1/8 00T NPTF (With dust cap)

Type 32P How to Order Applicable solenoid valve


Refer to page 505.
A, B port 10--SS5YJ3--32P-- 07 -- C4 Applicable connector

Air gripper
M5 x 0.8, C4 assembly
Clean series P, R port
thread type Refer to page 505.
Manifold stations A, B port size Nil Rc Applicable blanking
04 4 stations M5 M5 x 0.8
plate assembly
F G
SYJ3000-21-4A
P port : : C4 One-touch fitting for ø4 N NPT
R port (With dust cap)

Directional control
1/8 1/8 12 12 stations N3 One-touch fitting for ø5/32" T NPTF

valve
Mixed installation of the 10-SYJ300 and the 10-SY3000 valves on the same manifold
Series 10-SYJ300 valves can be mounted on the manifolds for 10-SY3000.

Flow control
equipment
q 10-SS5YJ3-20, 10-SS5YJ3-21P (10-SYJ300 3 port valve)
The 3 port valve can be used by simply sealing off the unused "R"
port with rubber plug, SYJ3000-33-1.
Applicable solenoid valves: Type 10-SYJ312M
Type 10-SYJ322M
(10-SYJ300 3 port valve)

control equipment
Filter, Pressure
w 10-SS5YJ3-31/-S31, 10-SS5YJ3-32/-S32,
10-SS5YJ3-46/-S46, 10-SS5YJ3-32P
The 3 port valve can be used without modification. Plug (SYJ3000-33-1) Plug (SYJ3000-33-1)
The A port of the valve will flow out of the B Seal the unused "R"
Seal the unused "R"
port of the manifold. port on the end cover port on the end cover
Applicable solenoid valve: Type 10-SYJ314M side of the manifold. side of the manifold.
Type 10-SYJ324M

Fittings & Tubing


e 10-SS5YJ3-41/-S41
The 3 port valve can be used by simply sealing off
the unused "R" port with rubber plug (SYJ3000-33-1).
The A port of the valve will flow out of the B port of the
manifold.
Applicable solenoid valve: Type 10-SYJ314M
Type 10-SYJ324M
Air preparation
equipment

Caution
Mounting screw tightening torque
M1.7: 0.12N·m Type 10-SS5YJ3-20 Type 10-SS5YJ3-41

Use caution to the assembly orientation for


"B" port becomes "A" port of 3 port valve.
Pressure switch

solenoid valves, gasket, and optional parts.


Clean gas filter

507
Manifold specifications 10-SYJ3000

<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base
5 port body ported 4 port base mounted 5 port base mounted
(Type 10-SYJ3첸23) (Type 10-SYJ3첸33) (Type 10-SYJ3첸43)
Round head combination screw
SY100-33-3
(M1.7 x 17, matt nickel plated)
Applicable manifold base Applicable manifold base Applicable manifold base
Type 10-SS5YJ3-31 Type 10-SS5YJ3-41
Type 10-SS5YJ3-20
Type 10-SS5YJ3-S31 Type 10-SS5YJ3-S41 Manifold
Type 10-SS5YJ3-21P Manifold
Type 10-SS5YJ3-32 base Type 10-SS5YJ3-46 base
Manifold base Type 10-SS5YJ3-S32 Type 10-SS5YJ3-S46
Type 10-SS5YJ3-32P
A mark A mark Protrusion for
positioning Manifold gasket
A
Manifold gasket A
Manifold gasket
SYJ3000-14-7 SYJ3000-14-6 SYJ3000-14-2
Note) Please insert the protrusion for positioning of
the manifold gasket into the hole of the valve
body completely.

Combination of blanking plate assembly and manifold base Difference between types 10-SYJ3첸33 and 10-SYJ3첸43
Blanking plate assembly Blanking plate assembly Type 10-3첸33 (4 port) Type 10-3첸43 (5 port)
SYJ3000-21-1A SYJ3000-21-2A
Round head
combination screw
Blanking plate Steel ball is driven in

Blanking plate

A mark A mark

Manifold gasket Manifold gasket

Applicable base Applicable base sub-plate


Type SS5YJ3-20 manifold base Type 10-SS5YJ3-41
Type 10-SS5YJ3-S41
Type 10-SS5YJ3-46
Type 10-SS5YJ3-S46
Manifold
Type 10-SS5YJ3-31 base
Type 10-SS5YJ3-S31 Configuration of this surface is different
Type 10-SS5YJ3-32
Type 10-SS5YJ3-S32
Note) The SYJ3000-14-2 manifold gasket can be used for
10-SS5YJ3-31/-S31 and 10-SS5YJ3-32/-S32 manifold
bases.

Blanking plate assembly Blanking plate assembly


SYJ3000-21-4A SYJ3000-21-3A
Round head
combination screw Round head
combination screw

Blanking plate
Blanking plate A mark
A mark

Manifold gasket
Manifold gasket

Dust cap Dust cap

Caution
Mounting screw tightening torque
M1.7: 0.12N·m
Applicable base Applicable base Use caution to the assembly orientation for
Type 10-SS5YJ3-32P manifold base Type 10-SS5YJ3-21P manifold base solenoid valves, gasket and option parts.

508
Manifold specifications 10-SYJ3000
Type 20 manifold: Top ported / 10-SS5YJ3-20- Stations ∗ [ ]: AC

(Lead wire length)


Grommet (G)

Approx. 300

Air cylinder
(Pitch)
P = 10.5 12.5
Manual

Rotary actuator
override

4 5

3.7
15.8

1.5
91.7[96.1]

78.8[83.2]
7 10
R
R

A A A A A

14
19.5

11 10
30.7
31.5

29
52.9[55.1]
53.7[55.9]

B B B B B

R
R

Air gripper
2-ø3.5 M5 x 0.8
(For mounting) (P, R port)

M3 x 0.5
(A, B port)
L2 3.5

Directional control
L1

valve
(Station n) (Station 1)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+

Flow control
42[49]

equipment
26.6
13.5

control equipment
Filter, Pressure
L plug connector (L) M plug connector (M) M8 connector (WO)
(Lead wire length)
Approx. 300

42[49]
26.6

Fittings & Tubing


M8 x 1
Approx. 300 53.1[60.1]
(Lead wire length)
1.5

1.5
1.5

Air preparation
111.5[115.9]

91.9[96.3]

equipment
109.7
98.6[103]

94.9
79[83.4]

96.8

82
53[55.2]
62.8[65]

54.5
61.9

Pressure switch
0.8

0.8
0.8
0.8

29
46.5

∗ Refer to page 563 for dimensions


Clean gas filter

with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 35.5 46 56.5 67 77.5 88 98.5 109 119.5 130 140.5 151 161.5 172 182.5 193 203.5 214 224.5
L2 28.5 39 49.5 60 70.5 81 91.5 102 112.5 123 133.5 144 154.5 165 175.5 186 196.5 207 217.5

509
Manifold specifications 10-SYJ3000
Type 31 manifold: Side ported / 10-SS5YJ3-31- Stations -M3 ∗ [ ]: AC

Grommet (G) Pilot valve of single solenoid


valve is located on the same
Type S3: Side ported side of A and B ports.
(Lead wire length)
Approx. 300

10-SS5YJ3-S31- Stations -M3


L1
3.5 L2

2-ø3.5
(For mounting) Manual
override
M5 x 0.8

5.2
7.5

17.3
(P, R port)
52.2[54.4]

51.4[53.6]

3
91.7[96.1]

78.8[83.2]
78.8[83.2]

13.5
A A A A A
B B B B B

R
R

R
29.2
91.7[96.1]

R
30

29.2
25
12
25

51.4[53.6]
30
52.2[54.4]
3 13.5

B B B B B

P
P

P
P

A A A A A
17.3

7.5
5.2

Manual override 2-ø3.5


(Pitch) (For mounting)
(Pitch) P = 10.5 9
12.5 P = 10.5 L2 3.5
L1

(Station 1) (Station n) (Station n) (Station 1)


(Light/surge voltage (Light/surge voltage suppressor)
suppressor)
43.5[50.5]

-+ -+ -+ -+ -+ -+ -+
28.1

A A B B
15

15
12

12

B B A A
3
3

1 (Pitch) (Pitch) 1
13.5 P = 10.5 M3 x 0.5 M3 x 0.5 P = 10.5 14.5
(A, B port) (A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1 48
30.5
0.8

0.8

0.8
0.8
61.3[63.5]

51.5[53.7]

60.4

53
98.6[103]
111.5[115.9]

79[83.4]
91.9[96.3]

96.8

82
109.7

94.9

Approx. 300 54.6[61.6]


(Lead wire length)
(Lead wire length)

28
Approx. 300

43.4[47.3]

∗ Refer to page 563 for dimensions


with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 35.5 46 56.5 67 77.5 88 98.5 109 119.5 130 140.5 151 161.5 172 182.5 193 203.5 214 224.5
L2 28.5 39 49.5 60 70.5 81 91.5 102 112.5 123 133.5 144 154.5 165 175.5 186 196.5 207 217.5

510
Manifold specifications 10-SYJ3000
C4
Type 32 manifold: Side ported / 10-SS5YJ3-32- Stations -M5, N3 첸 ∗ [ ]: AC

(Lead wire length)


Approx. 300
Grommet (G) C4첸(With built-in One-touch fitting)
L1 N3
4 L2 Manual override
M5 10

Air cylinder
2-ø4.5
(For mounting)

36.5
1/8

17
10

53.4[55.6]
54.2[56.4]
(P, R port)

78.8[83.2]
91.7[96.1]

31.5
3.2 31.2
R

12.5
(4.4)
B B B B B
32

17
1 16
P
P

A A A A A

7.5

Rotary actuator
15.3

(Station 1) (Station n)
L1
(Pitch) 4.5 L2
15.5 P = 10.5 (Light/surge voltage
15.5
suppressor)
(Station 1) (Station n) -+ -+

(Light/surge voltage suppressor)


A A

20
15
5
48.5[55.5]

B B
-+ -+

1.5 (Pitch) One-touch fitting


33.1

Air gripper
A A 16 P = 10.5 (A, B port)
20
15

B B
Applicable tubing O.D.:
5

1 (Pitch) M5 x 0.8 ø4 and ø5/32"


16.5 P = 10.5
(A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)

Directional control
M8 x 1 53
0.8

0.8
35.5
0.8

valve
0.8
63.3[65.5]

53.5[55.7]
111.5[115.9]

62.4
98.6[103]

79[83.4]
91.9[96.3]

55
96.8
109.7

82
94.9
1

Flow control
equipment
(Lead wire length)
Approx. 300

Approx. 300 59.6[66.6]


33.1 (Lead wire length)
48.4[55.4]
∗ Refer to page 563 for dimensions with
connector cable.

control equipment
Filter, Pressure
Pilot valve of single solenoid valve is C4
Type S32 manifold: Side ported located on the same side of A and B ports. / 10-SS5YJ3-S32- Stations -M5, N3 첸
L1 C4 첸(With built-in One-touch fitting)
M5 L2 4 N3

Fittings & Tubing


Manual
12.3

override 10
15.5

34.2 0.2
91.7[96.1]

78.8[83.2]

36.5
17
56.4[58.6]
57.2[59.4]

31.5
R

A A A A A
35

B B B B B
P
P

12.5
(4.4)

2-ø4.5
Air preparation

(Pitch) (Station n) (Station 1)


equipment

(For mounting) P = 10.5 15.5 L1


(Station n) (Station 1) L2 4.5
(Light/surge voltage suppressor)
15.5
(Light/surge voltage suppressor) -+ -+ -+ -+ -+

-+ -+ -+ -+ -+
B B
20
15
5

A A
B B
20

1
5
15

M5 x 0.8 (Pitch)
Pressure switch

A A

17.5 One-touch fitting


(A, B port) P = 10.5 (A, B port)
(Pitch) 1.5
P = 10.5 18
Applicable tubing O.D.:
ø4 and ø5/32"
SS5YJ3-32,S32- Stations -M5
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 41.5 52 62.5 73 83.5 94 104.5 115 125.5 136 146.5 157 167.5 178 188.5 199 209.5 220 230.5
Clean gas filter

L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5
10-SS5YJ3-32,S32- Stations -C4
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 42.5 53 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5
L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5

511
Manifold specifications 10-SYJ3000
Type 41 manifold: Side ported / 10-SS5YJ3-41- Stations -M5, C4
N3 첸 ∗ [ ]: AC

C4 첸 (With built-in One-touch fitting)

(Lead wire length)


Approx. 300
Grommet (G) (Pitch) N3
M5 16 P = 10.5 1/8
10 (P port)
Manual override
1/8

36.4
10 10
61.7[63.9]

60.9[63.1]
(P port)

21.4
78.8[83.2]
91.7[96.1]

R
39.5 B B B B B

38.7

36.5
18

4.3

21.5
R

(4.4)
P
A A A A A
3
11.5

7.8

1/8 (Station 1) (Station n)


(R port) 2-ø4.5 4 L2 (Light/surge voltage suppressor)
(For mounting) L1
(Station 1) (Station n) -+ -+

(Light/surge voltage suppressor)


A A

20
15
48.5[55.5]

B B

5
-+ -+

2 One-touch fitting
33.1

(Pitch)
A A
17 P = 10.5 (A, B port)
20
15
5

B B Applicable tubing O.D.:


2 ø4 and ø5/32"
(Pitch) M5 x 0.8
17 P = 10.5
(A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1 53
0.8

35.5

0.8
0.8

0.8
70.8[73]

61[63.2]

69.9
111.5[115.9]
98.6[103]

62.5
79[83.4]
91.9[96.3]

96.8
109.7

82
94.9
(Lead wire length)

Approx. 300 59.6[66.6]


Approx. 300

(Lead wire length)


33.1
48.5[55.5]
∗ Refer to page 563 for dimensions with
connector cable.

Pilot valve of single solenoid valve is C4


Type S41 manifold: Side ported located on the same side of A and B ports. 10-SS5YJ3-S41- Stations -M5, N3 첸
(Pitch)
P = 10.5 16 C4첸(With built-in One-touch fitting)
M5 N3
Manual
override
32.2 2.2
91.7[96.1]

33 14.3

78.8[83.2]

1/8
10
(P port)
54.4[56.6]

A A A A A
R
55.2[57.4]

33.5
36.5
P

B B B B B
R

36.4
21.4

2-ø4.5
(4.4)

L2 4 (For mounting)
L1
(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+

-+ -+ -+ -+ -+

B B
20
15

B B
20

A A
15

A A
5

2 (Pitch) 2
M5 x 0.8 (Pitch) One-touch fitting
P = 10.5 15
P = 10.5 15 (A, B port)
(A, B port)
Applicable tubing O.D.:
ø4 and ø5/32"
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5

512
Manifold specifications 10-SYJ3000
Type 46 manifold: Side ported / 10-SS5YJ3-46- Stations -M5, C4
N3 첸 ∗ [ ]: AC

Approx. 300
(Lead wire length)
Grommet (G) C4 첸 (With built-in One-touch fitting)
M5 (Pitch) N3

Air cylinder
14.5 P = 10.5
1/8
10 (P port)
Manual
override
1/8

34.9
10

59.9[62.1]
60.7[62.9] (P port)

18.9
78.8[83.2]
91.7[96.1]

B B B B B
38.5

37.7

35
3.3
P

(4.4)

Rotary actuator
19
A A A A A
10
8.8

2-ø4.5
4 L2 (For mounting) (Station 1) (Station n)
L1 (Light/surge voltage suppressor)

(Station 1) (Station n)
-+ -+
(Light/surge voltage suppressor)

Air gripper
48.5[55.5]

A A

20
15
-+ -+
B B

5
33.1

A A 1.5 (Pitch) One-touch fitting


20
15
5

B B 11.8 P = 10.5 (A, B port)


1.5 (Pitch) Applicable tubing O.D.:
11.8 P = 10.5 M5 x 0.8 ø4 and ø5/32"
(A, B port)

Directional control
L plug connector (L) M plug connector (M) M8 connector (WO)

valve
M8 x 1 53
0.8

35.5

0.8

0.8
0.8
69.8[72]

60[62.2]

68.9
111.5[115.9]
98.6[103]

61.5
79[83.4]
91.9[96.3]

Flow control
equipment
96.8
109.7

82
94.9
(Lead wire length)
Approx. 300

Approx. 300 59.6[66.6]

control equipment
Filter, Pressure
(Lead wire length)
33
48.5[55.5]
∗ Refer to page 563 for dimensions with
connector cable.

Fittings & Tubing


Pilot valve of single solenoid valve is C4
Type S46 manifold: Side ported located on the same side of A and B ports. /10-SS5YJ3-S46- Stations -M5, N3 첸
(Pitch)
P = 10.5 14.5 C4첸(With built-in One-touch fitting)
M5 N3
Manual
override
25 0.5
31.7 2.7
32.5 14.8
91.9[96.3]

1/8
78.8[83.2]

Air preparation

10
equipment

(P port)
A A A A A
53.9[56.1]
54.7[56.9]

25

35
P

B B B B B
34.9
18.9

2-ø4.5
(4.4)

L2 4 (For mounting)
L1
Pressure switch

(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)

-+ -+ -+ -+ -+
(Light/surge voltage suppressor) -+ -+ -+ -+ -+

B B
20

B B
20

15
15

A A
5

A A
5

(Pitch) 1.5 One-touch fitting (Pitch) 1.5


M5 x 0.8 P = 10.5 15.7 P = 10.5 15.7
Clean gas filter

(A, B port)
(A, B port) Applicable tubing O.D.:
ø4 and ø5/32"
Stations n 2 Stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Stations
L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5

513
Manifold specifications 10-SYJ3000

Flat ribbon cable manifold ∗ [ ]: AC

10-SS5YJ3-21P- Stations -00첸

L1
L2 4
Manual override
-+ -+ -+

M3 x 0.5 -+

(A, B port) 10
2 2

5.2
111.5[115.9]

30 17.3

7.5
7 8.5

16 3

98.6[103]
A

P
P

29.2

31.5
61.3[63.5]
62.1[64.3]

17
45.5
B

65.3
R

2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+

Triangle mark
(Pitch) 1/8
P=12.5 18.5 (P, R port)
(Station n) (Station 1)
(Light/surge voltage suppressor)
48.5[55.5]

25.6
5.8
20

28.5

Applicable connector: 26 pins MIL type


With strain relief
(Conforming to MIL-C-83503)

10-SS5YJ3-32P- Stations -M5, C4


N3 첸
C4 첸(With built-in One-touch fitting)
N3
M5 (Pitch)
P = 12.5 19.5
M5 x 0.8 1
(Pitch)
(A, B port)
5

B B
One-touch fitting (A, B port) P = 12.5 19.5
15

A
Applicable tubing O.D.: ø4 and ø5/32" 1
A

5
B B

15
20
A A

L1
L2 4
Manual override
-+ -+ -+

-+

10 10
3.2
32 15.3

7.5

(4.4)
111.5[115.9]

12.4
1

98.6[103]
16

A A A A A A
P
P

31.2

31.5
17
63.3[65.5]
64.1[66.3]

36.4

B B B B B B
R
R

65.3

17

50.4
70.2

2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+

Triangle mark
(Pitch) 1/8
P = 12.5 18.5 (P, R port) 1/8
(Station n) (Station 1) (P, R port)
(Light/surge voltage suppressor)
Applicable connector: 26 pins MIL type
With strain relief
48.5[55.5]

(Conforming to MIL-C-83503)
5.8
25.6
20

28.5 Stations n 4 Stations 5 6 7 8 9 10 11 12 Stations


L1 72.5 85 97.5 110 122.5 135 147.5 160 172.5
L2 64.5 77 89.5 102 114.5 127 139.5 152 164.5

514
Series 10-SYJ5000 Rubber seal
5 port solenoid valve

Air cylinder
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure
2 position double 0.1 to 0.7
range MPa
3 position 0.15 to 0.7
Ambient and fluid temperature -10 to 50°C (with no freezing. Refer to page 714.)

Rotary actuator
Response time ms Note 1) 2 position single, double 25 or less
(0.5 MPa) 3 position 40 or less
Max. operating 2 position single, double 5
frequency (Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the main and pilot valve
Lubrication Not required
Body ported
Mounting orientation Unrestricted

Air gripper
Impact/Vibration resistance m/s2 Note 2) 150/30
Enclosure Dustproof (∗ DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve
and armature in both energized and de-energized states every once for each condition. (Value in the initial state)

Directional control
Vibration resistance: No malfunction occurred in one sweep between 45 and 2000Hz. Test was performed in the axial direction and at the right angles
to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state)

valve
Solenoid specifications
Grommet(G), (H) , L plug connector (L),
M plug connector (M), DIN terminal (D),
Electrical entry M8 connector (W)
Base mounted
G, H, L, M, W D
JIS Symbol DC 24, 12, 6, 5, 3 24, 12
Rated coil voltage V

Flow control
equipment
AC 50/60Hz 100, 110, 200, 220
Body ported Base mounted Allowable voltage fluctuation ±10% of rated voltage ∗
(With sub-plate)
Standard 0.35 {With indicator light: 0.4 (DIN terminal with indicator light: 0.45)}
2 position single 2 position single Power consumption (W) DC
With power saving circuit 0.1 (With indicator light only)
(A) (B) (B)(A) 100V 0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)
4 2 2 4 110V 0.86 (With indicator light: 0.89) 0.86 (With indicator light: 0.97)
[115V] [0.94 (With indicator light: 0.97)] [0.94 (With indicator light: 1.07)]
Apparent power (VA) ∗ AC

control equipment
5 1 3 200V 1.18 (With indicator light: 1.22) 1.15 (With indicator light: 1.30)

Filter, Pressure
3 1
(R1) (P) (R2) (R)(P) 220V 1.30 (With indicator light: 1.34) 1.27 (With indicator light: 1.46)
2 position double 2 position double [230V] [1.42 (With indicator light: 1.46)] [1.39 (With indicator light: 1.60)]
(A) (B) (B)(A) Surge voltage suppressor Diode (DIN terminal, varistor for non-polar types)
4 2 2 4 Indicator light LED (Neon light for DIN terminal AC)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
5 1 3 3 1 ∗ For 115 and 230 VAC, the allowable voltage fluctuation is -15% to +5% of rated voltage.
(R1) (P) (R2) (R)(P) ∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please
observe the following range because they have voltage drop due to internal circuit.

Fittings & Tubing


3 position closed center 3 position closed center
(A) (B) (B)(A) S and Z types 24 VDC: -7% to +10% 12 VDC: -4% to +10%
4 2 2 4 T type 24 VDC: -8% to +10% 12 VDC: -6% to +10%

5 1 3
Built-in speed controller
(R1) (P) (R2) 3 1
(R)(P)
10-SYJ5첸53 Throttle valve characteristics ( AB →R)
앬 Built-in exhaust flow controls enable simple cylinder speed
3 position exhaust center 3 position exhaust center
adjustments.
Effective area (mm2)

(A) (B) (B)(A) 앬 When mounted on the manifold, the common exhaust discharges
Air preparation

4 2 2 4
the pilot and main valve exhaust through a common EXH port to 2
equipment

enable simple exhausting.


5 1 3 3 1
(R1) (P) (R2) (R)(P) (B) (A)
JIS Symbol 2 4 1
3 position pressure center 3 position pressure center
(A) (B) (B) (A)
4 2 2 4
3 1 (Single) 0
(R) (P) 1 2 3 4 5 6 7
Pressure switch

5 1 3
(Fully closed) (Fully open)
(R1) (P) (R2) 3 1
(R) (P)
How to order valve with Note) 앬 When using 10-SYJ5첸53 model, the speed controller
built-in speed controller must be opened more than 1 complete rotation from
fully closed in order to function properly.
Made to
10--SYJ5 53 -- -- 앬 Adjust the speed controller with a torque of 0.3 N·m
Order Made to order specifications or less.
Type of Port size
(Refer to page 557 for details.) actuation Plate fixing screw
Manual override
Clean gas filter

Clean series
Rated voltage Light/Surge voltage
Electrical entry suppressor
Note) Do not loosen plate fixing screw.

515
5 port solenoid valve Series 10-SYJ5000
Flow characteristics / Weight
Port size Flow characteristics Note 1) Weight (g) Note 2, 3)
Valve model Type of actuation 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
Grommet L/M plug DIN terminal M8 connector
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv connector
Single 46 47 68 51
2 position 0.47 0.41 0.13 0.47 0.41 0.13 74
Double 64 66 108
10-SYJ5첸23-첸-M5 Closed center M5 x 0.8 M5 x 0.8 0.49 0.44 0.13 0.44 0.40 0.12
3 position Exhaust center 0.46 0.37 0.12 0.47[0.39] 0.43[0.35] 0.13[0.10] 75 77 119 85
Pressure center 0.49[0.39] 0.51[0.38] 0.14[0.10] 0.45 0.42 0.12
Single 53 54 75 58
Body ported

2 position 0.69 0.39 0.18 0.44 0.39 0.12


Double C4 71 73 115 81
10-SYJ5첸23-첸-C4 Closed center M5 x 0.8 (One-touch 0.69 0.40 0.19 0.43 0.40 0.12
3 position Exhaust center fitting for ø4) 0.56 0.40 0.15 0.41[0.41] 0.37[0.37] 0.10[0.11] 82 84 126 72
Pressure center 0.57[0.41] 0.4[0.37] 0.15[0.10] 0.41 0.37 0.10
Single 53 54 75 58
2 position 0.70 0.36 0.19 0.47 0.40 0.12
Double C6 71 73 115 81
10-SYJ5첸23-첸-C6 Closed center M5 x 0.8 (One-touch 0.72 0.37 0.19 0.44 0.34 0.12
3 position Exhaust center fitting for ø6) 0.67 0.54 0.19 0.41[0.41] 0.38[0.38] 0.11[0.11] 82 84 126 92
Pressure center 0.82[0.44] 0.41[0.39] 0.23[0.12] 0.41 0.36 0.11
Single 80 (49) 81 (47) 102 (68) 51
Base mounted

2 position 0.79 0.21 0.19 0.83 0.32 0.21


Double 98 (64) 100 (66) 142 (108) 74
10-SYJ5첸43-첸-01 Closed center 1/8 1/8 0.80 0.28 0.18 0.86 0.34 0.20
3 position Exhaust center 0.71 0.26 0.18 1.1[0.60] 0.24[0.44] 0.26[0.18] 109 (75) 111 (77) 153 (119) 85
Pressure center 0.99[0.47] 0.29[0.38] 0.24[0.12] 0.72 0.38 0.18
Note 1) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate
Note 3) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types.

516
5 port solenoid valve Series 10-SYJ5000

How to Order
Light/Surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D

Air cylinder
Type of actuation Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
S With surge voltage suppresser S With surge voltage suppressor (Non-polar type)
1 2 position single solenoid
Z With light/surge voltage suppresser Z With light/surge voltage suppressor (Non-polar type)
2 2 position double solenoid
R With surge voltage suppresser (Non-polar type) ∗ "DOZ" is not available.
3 3 position closed center
U With light/surge voltage suppresser (Non-polar type) ∗ For AC voltage valves, there is no "S" option.
4 3 position exhaust center It is already built-in to the rectifier circuit.
5 3 position pressure center ∗ For AC voltage valves, there is no "S" option.
It is already built-in to the rectifier circuit. Bracket

Rotary actuator
∗ For "R" and "U", DC voltage is only available.
∗ Power saving circuit is only available in the "Z" type. Nil: Without bracket
F: With bracket
Rated voltage
DC specifications AC specifications (50/60Hz)
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC[115 VAC] M5 M5 x 0.8
S 5 VDC 4 220 VAC[230 VAC] C4 One-touch fitting for ø4

Air gripper
R 3 VDC ∗ For type "W첸", DC C6 One-touch fitting for ø6
∗ DC specifications voltage is only N3 One-touch fitting for ø5/32"
of type "D" and "DO" available. N7 One-touch fitting for ø1/4"
is only available with Note) The mounting bracket is
(For manifold type 20) 12 and 24 VDC. supplied unattached.

Directional control
Body ported 10 SYJ5 1 23 5 L M5

valve
Base mounted 10 SYJ5 2 43 5 L
Thread type
Clean series

Flow control
equipment
Nil Rc
Coil specifications Manual override F G
Nil Standard N NPT
Nil: Non-locking push type
With power saving circuit T NPTF
T
<For 24 and 12 VDC only>
∗ Power saving circuit is not
Port size

control equipment
Sub-plate, 40, 41, 42,
available in the case of "D",

Filter, Pressure
43 manifold
"DO" or "W첸" type. Nil: Without sub-plate

D: Push-turn locking
slotted type

Fittings & Tubing


(With gasket and screws)

01: 1/8 with sub-plate


Electrical entry
24, 12 VDC, 24, 12 VDC,
24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC 100, 110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector DIN terminal M8 connector E: Push-turn locking
Air preparation

G: Lead wire length L: With lead wire M: With lead wire MN: Without lead wire D: With connector WO: Without connector lever type
equipment

300 mm (length 300 mm) (length 300 mm) cable


–+
–+

–+
–+

Pressure switch

H: Lead wire length LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector W첸: With connector
600 mm cable Note 1)

–+
Clean gas filter
–+

Note 1) Be sure to enter a symbol of the cable


length with reference to page 562.
∗ "LN", "MN" types: with 2 sockets.
∗ DIN terminal type "Y" conforming to EN-175301-803C (former DIN43650C) is also available. For details, refer to page 557.
∗ For connector cable of M8 connector, refer to page 562.

517
5 port solenoid valve Series 10-SYJ5000

How to Order Pilot Valve Assembly How to Order Connector Assembly for L/M Plug Connector

10 V111 5 G For DC :SY100-30-4A-


Clean series
Light/Surge voltage suppressor For 100 VAC :SY100-30-1A-
Coil specifications Nil Without light/surge voltage suppressor
Nil Standard S With surge voltage suppressor For 200 VAC :SY100-30-2A-
With power saving circuit Z With light/surge voltage suppressor
T
<24 and 12 VDC only> R With surge voltage suppressor (Non-polar type) For other voltages of AC :SY100-30-3A-
∗ Power saving circuit is U With light/surge voltage suppressor (Non-polar type)
not available in the ∗ For AC voltage valves, there is no
case of "W첸" type. "S" option. It is already built-in to the Without lead wire :SY100-30-A
rectifier circuit. (With connector and 2 of sockets only)
∗ For "R" and "U", DC voltage is only
Rated voltage available. Lead wire length
∗ Power saving circuit is only available
5 24 VDC in the "Z" type. Nil 300mm
6 12 VDC 6 600mm
V 6 VDC
Electrical entry
10 1000mm
S 5 VDC G Grommet (Lead wire length 300 mm)
15 1500mm
R 3 VDC H Grommet (Lead wire length 600 mm)
20 2000mm
1 100 VAC 50/60Hz L With lead wire
L plug 25 2500mm
2 200 VAC 50/60Hz LN connector Without lead wire
30 3000mm
110 VAC 50/60Hz LO Without connector
3 50 5000mm
[115 VAC 50/60Hz] M With lead wire
M plug
220 VAC 50/60Hz MN connector Without lead wire
4 MO Without connector
[230 VAC 50/60Hz]
∗ For type "W첸", DC WO M8 Without connector cable
voltage is only W첸 connector Without connector cable Note 1)
available. ∗ For connector cable of M8 connector,
refer to page 562.
How to Order M8 Connector Cable
Note 1) Be sure to enter a symbol of the
cable length with reference to
page 562. V100-49-1-

10 V115 5 D Cable length


1 300mm
Clean series 2 500mm
3 1000mm
Rated voltage
4 2000mm
5 24 VDC
Light/surge voltage suppressor 7 5000mm
6 12 VDC
1 100 VAC 50 60 Hz Nil Without light/surge voltage suppressor
2 200 VAC 50 60 Hz S With surge voltage suppressor (Non-polar type)
110 VAC 50 60 Hz Z With light/surge voltage suppressor (Non-polar type)
3
[115 VAC 50 60 Hz] ∗ "DOZ" is not available.
50 60 Hz
∗ For AC voltage valves, there is no "S" option. It is
220 VAC
4 50 60 Hz]
already built-in to the rectifier circuit.
[230 VAC
∗ DC specifications Electrical entry
of type "D" and D With connector
DIN
"DO" is only
DO terminal Without connector
available with 12
and 24 V DC. Note) Do not replace 10-V111 (G, H, L, M,
∗ Power saving circuit W) to 10-V115 (DIN terminal) and
is not available in vice versa when replacing pilot
the case of "D" or valve assembly only.
"DO" type.

518
5 port solenoid valve Series 10-SYJ5000

2 position single ∗ [ ]: AC

G
Grommet (G), (H):10- SYJ5123-첸 첸첸-M5 H With bracket
G
10-SYJ5123-첸 H 첸첸-M5-F

Air cylinder
37
G: Approx. 300
63.1[65.3] H: Approx. 600 2-ø3.5 30 3.5
(Lead wire length) (For mounting)
41
19.5

18
25
-+

Rotary actuator
11

19.7
5

A B

35.1[42.1]
M5 x 0.8 10 Manual override
(A, B port) 19 2-ø2.6
(For manifold mounting)

63.1[65.3]
2-M3 x 0.5 (Light/surge voltage suppressor)

Air gripper
(Mounting screw)

-+
18

23
20

(Bracket)

2.3
28.1[35.1]
2.5

12.7
10.6 11 2-ø2.6 Built-in One-touch Fitting:

Directional control
3.5 4 (For mounting) G C4,N3
10-SYJ5123-첸 H 첸첸- C6,N7 (-F)

valve
19.5

3.5
A B
R1 P
16

15

R2 10.6 One-touch fitting

Flow control
M5 x 0.8 21 (3.2)

equipment
(A, B port)
(P, R1, R2 port) Applicable tubing O.D.: ø4 and ø5/32"
: ø6, ø1/4"
32.3

control equipment
(2.3)

Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5123-첸L첸첸-M5(-F) 10-SYJ5123-첸M첸첸-M5(-F) 10-SYJ5123-첸D첸첸-M5(-F) 10-SYJ5123-첸WO첸첸-M5(-F)

Fittings & Tubing


(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7
MAX.10

28.1[35.1] 60.9
53.4
12.7
42.1
M8 x 1 32.6
Air preparation

15.1
equipment

Approx. 300 39.2[46.2]


(Lead wire length) Pg7
73[75.2]

63.2[65.4]

82.1

83

72.1
58.2

64.7

3 3 3 3
42.2

Pressure switch
19.5

19.5

19.5
11
11
11

19.5
11

20 2-ø2.6 20 2-ø2.6 20 2-ø2.6


(2.3)

(2.3)

(2.3)

20 2-ø2.6
(2.3)

23 (For mounting) (For mounting) 23 (For mounting)


23 23 (For mounting)
27
Clean gas filter

∗ Refer to page 563 for dimensions


with connector cable.

519
5 port solenoid valve Series 10-SYJ5000

2 position double ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ5223-첸 H 첸첸-M5 Built-in One-touch fitting
10-SYJ5223-첸 GH 첸첸-C4,N3
C6,N7

G: Approx. 300
87.2[91.6] H: Approx. 600
43 (Lead wire length)

3.5
11
5

A B A B

10 Manual override 10.6


M5 x 0.8 19 2-ø2.6
(A, B port) (For manifold mounting)

One-touch fitting

(3.2)
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D.: ø4 and ø5/32"
        : ø6, ø1/4"

32.3
-+
23
20

12.7
28.1[35.1]
3

11 2-ø2.6
(For mounting)

R1 P
15

R2
M5 x 0.8 21
(P, R1, R2 port)

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5223-첸L첸첸-M5 10-SYJ5223-첸M첸첸-M5 10-SYJ5223-첸D첸첸-M5 10-SYJ5223-첸WO첸첸-M5
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7
MAX.10

28.1[35.1] 60.9
12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2[46.2]
(Lead wire length)
Pg7

20 20 20 20
107[111.4]

3 3 3
87.4[91.8]

3
105.2
125.2

90.4
77.4

45.4

127

11
11

11
11

23
2-ø2.6 2-ø2.6 2-ø2.6
(For mounting) (For mounting) (For mounting)

23
23
23
27
2-ø2.6
(For mounting)

∗ Refer to page 563 for dimensions


with connector cable.

520
5 port solenoid valve Series 10-SYJ5000
3 position closed center / exhaust center / pressure center ∗ [ ]: AC

3
Grommet (G), (H): 10-SYJ5 45 23-첸GH 첸첸-M5 Built-in One-touch fitting:
3
10-SYJ5 45 23-첸GH 첸첸- C4,N3

Air cylinder
C6,N7

G: Approx. 300
103.2[107.6] H: Approx. 600
44.2[46.4] (Lead wire length)
36.9 22.1 44.2[46.4]

3.5
11
5

Rotary actuator
A B A B

M5 x 0.8 10 Manual override 10.6


(A, B port) 19
2-ø2.6
(For manifold mounting)

One-touch fitting

(3.2)
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D: ø4 and

Air gripper
ø5/32"

32.3
: ø6, ø1/4"
-+
23
20

12.7
28.1[35.1]
3

11 2-ø2.6
(For mounting)

Directional control
valve
R1 P
15

R2
M5 x 0.8 21
(P, R1, R2 port)

Flow control
equipment
control equipment
Filter, Pressure
L plug connector
3
(L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3
10-SYJ5 5 23-첸L첸첸-M5
4 10-SYJ5 45 23-첸M첸첸-M5 10-SYJ5 45 23-첸D첸첸-M5 10-SYJ5 45 23-첸WO첸첸-M5
(Lead wire length)

Fittings & Tubing


Approx. 300

Applicable cable O.D


ø3.5 to ø7
MAX.10

28.1[35.1] 60.9
12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2[46.2]
(Lead wire length)
Air preparation

Pg7
equipment
54.1[56.3]

44.3[46.5]

64.1
63.2

53.2
45.8
39.3

20 20 20 20
23.3

3 3 3 3
103.4[107.8]
123[127.4]

11
11

11
141.2

121.2
143
11
38.1

23 2-ø2.6 23 2-ø2.6 23 23
Pressure switch
54.1

60.6

(For mounting) (For mounting) 2-ø2.6 2-ø2.6


(For (For
mounting) mounting)

27
Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

521
5 port solenoid valve Series 10-SYJ5000

2 position single ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ5143-첸 H 첸첸-01첸 Built-in speed controller:
G
10-SYJ5153-첸 H 첸첸-01첸

MAX.13.5
1/8 19.4 10.3
17 11.5
(A, B port)

8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A

24
B

R P

G: Approx. 300 41 0.5


H: Approx. 600 63.6[65.8]
(Lead wire length)

(Light/surge voltage suppressor)


50.1[57.1]

-+
45

8.5
34.7

21.5

15 17 17
24 1/8 45.5
32 (P, R port)

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5143-첸L첸첸-01첸 10-SYJ5143-첸M첸첸-01첸 10-SYJ5143-첸D첸첸-01첸 10-SYJ5143-첸WO첸첸-01첸
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7
82.9
MAX.10

50.1[57.1] 75.4
34.7 64.1
49 54.6 M8 x 1
37.1
61.2[68.2] Approx. 300
(Lead wire length) Pg7
6 6 6 6
73.5[75.7]

63.7[65.9]

83.5

82.6

65.2
72.6
58.7
45.5

45.5

45.5

45.5
17 17

17 17

17 17

17 17
42.7
0.5

0.5
0.5

6 6 6 6
0.5

8.5 8.5 8.5 8.5


21.5 21.5 21.5 21.5

∗ Refer to page 563 for dimensions with connector cable.

522
5 port solenoid valve Series 10-SYJ5000

2 position double ∗ [ ]: AC

Grommet (G), (H): 10-SYJ5243-첸GH 첸첸-01첸 Built-in speed controller:


10-SYJ5253-첸 GH 첸첸-01첸

Air cylinder
1/8 17 11.5
(A, B port)

MAX.13.5
8.5
19.4 10.3

Rotary actuator
2-ø4.3
(For mounting)
37.5 4
Manual override
B A

24
B

Air gripper
R P

41.5 1.5
G: Approx. 300 23.6[25.8]
H: Approx. 600 87.2[91.6]
(Lead wire length)

Directional control
(Light/surge voltage suppressor)

valve
50.1[57.1]

-+
45
34.7

8.5
21.5

Flow control
15 17 17

equipment
24 1/8 45.5
32 (P, R port)

control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5243-첸L첸첸-01첸 10-SYJ5243-첸M첸첸-01첸 10-SYJ5243-첸D첸첸-01첸 10-SYJ5243-첸WO첸첸-01첸

Fittings & Tubing


Applicable cable O.D
(Lead wire length)

ø3.5 to ø7
Approx. 300

82.9
MAX.10

50.1[57.1] 75.4
34.7 64.1
49 54.6
M8 x 1
61.2[68.2] Approx. 300 37.1
Air preparation
equipment

(Lead wire length) Pg7


6 6 6 6
107[111.4]

65.2
87.4[91.8]
58.7
45.5

45.5

45.5

45.5
125.2

105.2
17 17

17 17

17 17

17 17
42.7
127

2.7

Pressure switch
18.7

6 6 6 6
25.2
32.6
42.6

8.5 8.5 8.5


43.5

8.5
21.5
23.7[25.9]

21.5 21.5 21.5


33.5[35.7]

Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

523
5 port solenoid valve Series 10-SYJ5000

3 position closed center / Exhaust center / Pressure center ∗ [ ]: AC


3
Grommet (G), (H): 10-SYJ5 45 43-첸GH 첸첸-01첸 Built-in speed controller:
3
10-SYJ5 45 53-첸 GH 첸첸-01첸

1/8 17 11.5

MAX.13.5
(A, B port)
19.4 10.3

8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A

24
B

R P

42.1 16.9
39[41.2]
G: Approx. 300
H: Approx. 600 103.2[107.6]
(Lead wire length)

(Light/surge voltage suppressor)


50.1[57.1]

-+
45
34.7

21.5

15 17 17
8.5

1/8
24 45.5
(P, R port)
32

L plug connector
3
(L): M plug connector
3
(M): DIN Terminal
3
(D): M8 connector
3
(WO):
10-SYJ5 45 43-첸L첸첸-01첸 10-SYJ5 45 43-첸M첸첸-01첸 10-SYJ5 45 43-첸D첸첸-01첸 10-SYJ5 45 43-첸WO첸첸-01첸
Applicable cable O.D.
(Lead wire length)

ø3.5 to ø7
Approx. 300

82.9
MAX.10

50.1[57.1] 75.4
64.1
34.7
49 54.6 M8 x 1
61.2[68.2] Approx. 300 37.1
(Lead wire length) Pg7
6 6 6 6
65.8
59.3

103.4[107.8]
123[127.4]
45.5

45.5

45.5

45.5
43.3
17 17

17 17

17 17

17 17
141.2

121.2
143

18.1

6 6 6 6
48.9[51.1]

34.1

40.6

8.5 8.5 8.5 8.5


48
58.9

58

21.5 21.5 21.5 21.5


39.1[41.3]

∗ Refer to page 563 for dimensions with connector cable.

524
Series10-SYJ5000 Manifold specifications

Air cylinder
Manifold standard

Manifold specifications

Model Type 20 Type 40 Type 41 Type 42 Type 43

Rotary actuator
Manifold type Single base / B mount

P (SUP) / R (EXH) Common SUP / Common EXH

Valve stations 2 to 20 stations


A, B port piping Location Valve Base Base
specifications Direction Top Bottom Side

Air gripper
P, R port 1/8 1/4 1/8
Port size M5 x 0.8 1/8, C6
C4 (One-touch
A, B port C4 (One-touch fitting for ø4) M5 x 0.8 (One-touch
C6 (One-touch fitting for ø6) fitting for ø6) fitting for ø4)

Directional control
Flow characteristics

valve
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3(A/B→R)
Manifold model
1(P), 5/3(R) 2(B), 4(A) C C
port port [dm3/(s·bar)] b Cv [dm3/(s·bar)] b Cv
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
10- SS5YJ5-20 10-SYJ5첸23 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
for internal pilot

Flow control
equipment
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
10-SS5YJ5-40 1/8 M5 x 0.8 0.55 0.35 0.15 0.64 0.26 0.16
10-SS5YJ5-41 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
Base mounted
10-SS5YJ5-42-01 10-SYJ5첸43 1/4 1/8 0.74 0.22 0.18 0.82 0.31 0.21
for internal pilot
10-SS5YJ5-42-C6 1/4 C6 0.71 0.24 0.17 0.8 0.29 0.20
10-SS5YJ5-43 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19

control equipment
Note) Value at manifold base mounted, 2 position single operating

Filter, Pressure
How to Order Manifold (Example)

Fittings & Tubing


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model number.
Example 10-SS5YJ5-20-03 ············· 1 set (Manifold base)
∗ 10-SYJ5123-5G-M5 ·········· 2 sets (Valve)
∗ SYJ5000-21-4A ················ 1 set (Blanking plate assembly)
Air preparation

10-SS5YJ5-43-03-C4 ······· 1 set (Manifold base)


equipment

∗ 10-SYJ5143-5LZ ·············· 1 set (Valve)


∗ 10-SYJ5243-5LZ ·············· 1 set (Valve)
∗ SYJ5000-21-4A ················ 1 set (Blanking plate assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.


Pressure switch
Clean gas filter

525
Manifold specifications 10-SYJ5000

Flat ribbon cable manifold


• Multiple valve wiring is Flat ribbon cable manifold specifications
simplified through the
Model Type 20P Type 41P Type 43P
use of the flat ribbon Manifold type Single base / B mount
cable connector. P(SUP) / R(EXH) Common SUP / Common EXH
Valve stations 3 to 12 stations
• Clean appearance A, B port piping Location Valve Base
In the case of a flat ribbon cable type, each specifications Direction Top Side
valve is wired on the print board of manifold P, R port 1/8 1/8
base to allow the external wiring to be piped Port size M5 x 0.8
all together with 26 pins MIL connector. A, B port C4 (One-touch fitting for ø4) M5 x 0.8 C4 (One-touch fitting for ø4)
C6 (One-touch fitting for ø6)
Applicable flat ribbon
Socket: 26 pins MIL type with strain relief (Conforming to MIL-C-83503)
cable connector
Internal wiring In common between +COM and –COM (Z type: +COM only)
Rated voltage 12, 24 VDC 100, 110 VAC
Note) The withstand voltage specification for the wiring section conforms to JIS C0704, Grade 1 or its
equivalent.

Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
10-SS5YJ5-20P 10-SYJ5첸23 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
for internal pilot
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
Base mounted 10-SS5YJ5-41P 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
10-SYJ5첸43
for internal pilot 10-SS5YJ5-43P 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifolds (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model number.
Example
10-SS5YJ5-41P-07-C4 ······ 1 set (Manifold base)
∗ 10-SYJ5143-5LOU ············ 3 sets (Valve)
∗ 10-SYJ5243-5LOU ············ 3 sets (Valve)
∗ SYJ5000-21-3A ················· 1 set (Blanking plate assembly)
∗ SY3000-37-28A ················· 3 sets (Connector assembly)
∗ SY3000-37-29A ················· 3 sets (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

How to Order Valves How to Order Connector Assembly


Rated voltage Light/surge voltage suppressor 12, 24 VDC
Z With light/surge voltage suppressor Single solenoid SY3000-37-28A
5 24 VDC
Clean series U With light/surge voltage suppressor (Non-polar type) Double solenoid 3 position type SY3000-37-29A
6 12 VDC
Note) Z: Positive common specifications only. For single solenoid, individual SUP/EXH spacer SY3000-37-3A
For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-4A
2
For DC 10 SYJ5 1 4 3 5 LO Z For 3 port adaptor plate
For 100 VAC
SY3000-37-3A

For single solenoid SY3000-37-46A


2
For AC 10 SYJ5 1 4 3 1 LOZ Double solenoid 3 position type SY3000-37-47A
For single solenoid, individual SUP/EXH spacer SY3000-37-32A
Type of actuation For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-33A
1 2 position single 3 port adaptor plate SY3000-37-32A
2 2 position double A, B port size For 100 VAC (115 VAC)
3 3 position closed center Symbol Port size For single solenoid SY3000-37-54A
4 3 position exhaust center Nil Base mounted Double solenoid 3 position type SY3000-37-55A
5 3 position pressure center Rated voltage M5 M5 x 0.8 For single solenoid, individual SUP/EXH spacer SY3000-37-35A
C4 One-touch fitting for ø4 For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-36A
1 100 VAC
C6 One-touch fitting for ø6 For 3 port adaptor plate SY3000-37-35A
3 110 VAC(115 VAC)
N3 One-touch fitting for ø5/32"
Manual override N7 One-touch fitting for ø1/4"
Nil Non-locking push type Note) In the case of flat ribbon cable type, "U" and "Z"
D Push-turn locking slotted type types are for DC specifications and "Z" type is for
AC specifications. "Z" type for DC is positive
E Push-turn locking lever type
common specifications only. For other
combinations, please contact SMC.

526
Manifold specifications 10-SYJ5000

Common SUP / Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20 (5 port / Body ported) How to Order Applicable solenoid valve


M5
10-SYJ5첸23-첸첸첸첸- C4
A, B port 10 SS5YJ5 20 05 C6

Air cylinder
M5 x 0.8 Applicable blanking
Clean series plate assembly
-+ P, R port
-+
P port Number of stations thread type SYJ5000-21-4A
1/8 02 2 stations Applicable individual

R
Nil Rc
P
R
: : 00F G EXH spacer assembly
R port 20 20 stations 00N NPT SYJ5000-17-1A

Rotary actuator
1/8 00T NPTF

Type 40 (5 port / Base mounted) How to Order Applicable solenoid valve


10-SYJ5첸43-첸첸첸첸
10 SS5YJ5 40 05 M5 10-SYJ5첸53-첸첸첸첸
P port
Clean series Applicable blanking
1/8
P, R port plate assembly
Number of stations thread type SYJ5000-21-4A

Air gripper
02 2 stations Nil Rc Applicable individual
: : F G EXH spacer assembly
R port
20 20 stations N NPT SYJ5000-17-1A
A, B port 1/8
T NPTF
M5 x 0.8 A, B port size
M5 M5 x 0.8

Directional control
valve
Type 41 (5 port / base mounted) How to Order
10 SS5YJ5 41 05 M5
Clean series
Number of stations

Flow control
equipment
-+
-+ 02 2 stations P, R port
R port thread type
: :
R

1/8 Nil Rc
P

A, B port 20 20 stations
F G
M5 x 0.8 P port
A, B port size N NPT
1/8
M5 M5 x 0.8 T NPTF

control equipment
Filter, Pressure
Type 42 (5 port / base mounted) How to Order
Applicable solenoid valve
10 SS5YJ5 42 05 C6 10-SYJ5첸43-첸첸첸첸
Clean series 10-SYJ5첸53-첸첸첸첸
Number of stations Applicable blanking
-+ 02 2 stations plate assembly
-+

Fittings & Tubing


B
R port
: : SYJ5000-21-4A
R

20 20 stations Applicable individual


P

1/4
A Thread type
A, B port size EXH spacer assembly
A, B port B Nil Rc
P port
01 1/8
SYJ5000-17-1A
1/8, C6 F G
1/4
C6 One-touch fitting for ø6
Applicable individual
N NPT
SUP spacer assembly
N7 One-touch fitting for ø1/4" T NPTF
SYJ5000-16-2A
Air preparation

Type 43 (5 port / base mounted) How to Order


equipment

10 SS5YJ5 43 05 C4
Clean series
Manifold stations
-+
-+ 02 2 stations
Pressure switch

R port : : P, R port
R

thread type
P

1/8
A, B port A 20 20 stations
B Nil Rc
C4 P port
A, B port size F G
1/8
C4 One-touch fitting for ø4 N NPT
N3 One-touch fitting for ø5/32" T NPTF
Clean gas filter

527
Manifold specifications 10-SYJ5000
Flat ribbon cable manifold
Common SUP / Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20P (5 port / body ported) How to Order Applicable solenoid valve
Refer to page 526.
A, B port
10 SS5YJ5 20P-- 05
Applicable blanking
P port Clean series P, R port plate assembly
1/8 thread type SYJ5000-21-3A
Number of stations
Nil Rc
03 3 stations
00F G Applicable connector
: : assembly
R port 00N NPT
1/8 12 12 stations 00T NPTF Refer to page 526.

Type 41P (5 port / base mounted) How to Order


10 SS5YJ5 41P 05 M5
A, B port Clean series P, R port size
M5 x 0.8 Applicable solenoid valve
Number of stations Nil Rc Refer to page 526.
P port
03 3 stations F G
1/8
: : N NPT
R port 12 12 stations T NPTF Applicable blanking
1/8 plate assembly
Type 43P (5 port / base mounted) How to Order SYJ5000-21-3A

10 SS5YJ5 43P 05 C4 Applicable connector


A, B port assembly
C4
Clean series P, R port Refer to page 526.
Number of stations thread type
P port 03 3 stations A, B port size Nil Rc
1/8
: : C4 One-touch fitting for ø4 F G
R port 12 12 stations N3 One-touch fitting for ø5/32" N NPT
1/8 T NPTF

<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base
Round head combination screw Round head combination screw
M2.5 x 25 M2.5 x 25
Matt nickel plated Matt nickel plated
(With spring washer) (With spring washer)

Manifold gasket Manifold gasket


DXT192-10-14 DXT192-10-16

Blanking plate assembly


SYJ5000-21-4A SYJ5000-21-3A
Round head combination screw Round head combination screw

Blanking plate
Blanking plate

Gasket Gasket
Caution
Applicable base Mounting screw tightening torque
· 10-SS5YJ5-20
M2.5: 0.45N·m
· 10-SS5YJ5-40 Dust cap Applicable base
· 10-SS5YJ5-41 · 10-SS5YJ5-20P Use caution to the assembly
· 10-SS5YJ5-42 orientation for solenoid valve,
· 10-SS5YJ5-41P
· 10-SS5YJ5-43
gasket, and optional parts.
· 10-SS5YJ5-43P

528
Manifold specifications 10-SYJ5000

<Manifold option>
Mix installation of the 10-SYJ500 and the 10-SYJ5000 valves on the same manifold
앬 Use of an adapter plate makes it possible to mount Series 10-SYJ500 on the manifold bases of series 10-SYJ5000.

Air cylinder
앬 When mounting the 10-SYJ500 valve on the 10-SYJ5000 manifold, the 10-SYJ500 solenoid must be positioned on the same side of the manifold as a single solenoid of 10-SYJ5000.
앬 For base mounted style, the A port of the 3 port valve flows out the B port of manifold base.

Adaptor plate assembly


SYJ500-3-2A SYJ500-3-1A

Rotary actuator
Round head combination screw

Gasket

Air gripper
Round head combination screw
Round head combination screw

Adaptor plate
7

Adaptor plate
7
Adaptor gasket

Directional control
valve
Adaptor gasket Applicable base
· 10-SS5YJ5-40
Applicable base · 10-SS5YJ5-41
· 10-SS5YJ5-20 · 10-SS5YJ5-42
· 10-SS5YJ5-43

Individual EXH spacer assembly Individual SUP spacer assembly

Flow control
equipment
SYJ5000-17-1A
SYJ5000-16-2 A
Round head combination screw Round head combination screw
Thread type
Nil Rc

control equipment
Filter, Pressure
F G
N NPT
T NPTF
B

A
A

Manifold gasket
Manifold gasket

Fittings & Tubing


10

15

Individual EXH spacer

Individual SUP spacer


Air preparation
equipment

Applicable base Applicable base


· 10-SS5YJ5-20 · 10-SS5YJ5-41
· 10-SS5YJ5-40 · 10-SS5YJ5-42
· 10-SS5YJ5-41 · 10-SS5YJ5-43
· 10-SS5YJ5-42
· 10-SS5YJ5-43
Caution
Pressure switch

Mounting screw tightening torque


M2.5: 0.45N·m
Use caution to the assembly
orientation for solenoid
valves, gasket, and optional
parts.
Clean gas filter

529
Manifold specifications 10-SYJ5000
Type 20: Top ported / 10-SS5YJ5-20- Station -00첸 ∗ [ ]: AC

Grommet (G)
(Lead wire length)
Approx. 300

(DIN: 14.6)

(Pitch)

10 18.5 (DIN: 0.8)


P = 16 21
13.4

2.5 2.5 12.5


2
103.2[107.6]

16.515.2

(DIN: 46.2)
(DIN: 46.8)

23.5
87.2[91.6]

16.516.5
R

R
A

A
45.6

67.1[69.3]
67.7[69.9]

45

49
P

P
B

B
R

4-ø4.5 1/8
(For mounting) (P, R port)
M5 x 0.8
Manual override L2 9 (A, B port)
L1
Built-in One-touch fitting

(Station n) (Station 1)

(Light/surge voltage suppressor)


48.6[55.6]

-+ -+ -+ -+ -+
33.2

20

(3.2) 52.8

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
Approx. 300

MAX.10

Applicable cable O.D


Pg7
ø3.5 to ø7
(Lead wire length)
Approx. 300 59.7[66.7] M8 x 1
103.4[107.8]
123[127.4]
107[111.4]

87.4[91.8]

141.2

121.2

106.4
143
125.2

105.2
67.2[69.4]

90.4
127
77[79.2]

68.7
76.1
86.1

87
0.6

0.6

35.6
0.6
0.6

33.2
53.1
0.6
0.6

48.6[55.6] 62.6
73.9
81.4

∗ Refer to page 563 for dimensions with connector cable.


Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330 346
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328

530
Manifold specifications 10-SYJ5000
Type 40: Bottom ported / 10-SS5YJ5-40- Stations -M5첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300

Air cylinder
L1
L2 9

4-ø4.5
(For mounting)

Rotary actuator
13
8.5
(DIN: 23.3) (DIN: 38.1)

(DIN: 22.7) (DIN: 22.7)


103.2[107.6]

16.5

43.6[45.8] 23.5
22.1 36.9

21.5 21.5
R

A A A A A

87.2[91.6]

33
47
P

P
44.2[46.4]

B B B B B
R

2.5

Air gripper
1/8
(Pitch) (P, R port)
P = 16 21 Manual override

(Station n) (Station 1)

(Light/surge voltage suppressor) Built-in speed controller


48.6[55.6]

Directional control
-+ -+ -+ -+ -+
33.2

valve
20

M5 x 0.8
(A, B port)

Flow control
equipment
12
24

MAX.13.5 43.5

control equipment
(Pitch)

Filter, Pressure
P = 16 23

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
Approx. 300

MAX.10

Fittings & Tubing


Applicable cable O.D
Pg7 ø3.5 to ø7
(Lead wire length)
Approx. 300 59.7[66.7] M8 x 1
Air preparation
103.4[107.8]

equipment
123[127.4]
107[111.4]

87.4[91.8]

141.2

121.2

106.4
143
125.2

105.2

90.4
127
43.7[45.9]
53.5[55.7]

45.2
52.6
62.6

63.5

Pressure switch
0.6

0.6

35.6
0.6
0.6

33.2
53.1
0.6

62.6
0.6

48.6[55.6]
73.9
81.4
Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330 346
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328

531
Manifold specifications 10-SYJ5000
Type 41: Side ported / 10-SS5YJ5-41- Stations -M5첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300

L1
4.5 L2 Manual override

2-ø5.5
(For mounting)

12
60.2[62.4]

59.6[61.8]
(DIN: 38.7)
(DIN: 22.1) (DIN: 39.3)

87.2[91.6]
103.2[107.6]

R
B B B B B
38.1

21
35
5.5 37.5
3.5 17.5
P

A A A A A

7
20.9

(DIN: 6.7) 1/8


(P, R port)

(Pitch)
18 P = 16

Built-in speed controller


(Station 1) (Station n)
MAX.13.5 47.5

(Light/surge voltage suppressor)


52.6[59.6]

-+ -+ -+
37.2

A A
18.5
24

B B
5.5

(Pitch)
23 P = 16
M5 x 0.8
(A, B port)

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)

85.4
77.9
52.6[59.6] 66.6
0.6

M8 x 1
0.6

57.1
37.2
0.6

39.6
0.6
0.6

0.6
69.5[71.7]

59.7[61.9]

79.5
78.6

68.6

61.2
107[111.4]

87.4[91.8]
103.4[107.8]
123[127.4]

125.2

105.2
127

90.4
141.2

121.2

106.4
143
3.5
3.5

3.5
3.5

Approx. 300 63.7[70.7]


(Lead wire length)

Pg7
MAX.10
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340
L2 43 59 75 91 107 123 139 155 171 187 203 219 235 251 267 283 299 315 331

532
Manifold specifications 10-SYJ5000
Type 42: Side ported / 10-SS5YJ5-42- Stations -01, C6
N7 첸 ∗ [ ]: AC

Grommet (G) C6
01첸 N7 첸(With built-in One-touch fitting)

Air cylinder
(Lead wire length)
Approx. 300

L1 Manual override
6.5 L2
2-ø6.5

Rotary actuator
(For mounting)

17.5 17.5
65.2[67.4]

64.6[66.8]
(DIN: 43.7)
(DIN: 44.3)

87.2[91.6]
103.2[107.6]

B B B B B

43.9
24

24
44
0.5 42.5
43.1

23
P

A A A A A

10.4
(DIN: 1.7)

10.5

Air gripper
15.9
(DIN: 17.1)

1/4 1/4
(Pitch) (P, R port)
24.5 P = 17 (P, R port)

(Station 1) (Station n)

Directional control
(Station 1) (Station n)
(Light/surge voltage suppressor) Built-in speed controller (Light/surge voltage suppressor)

valve
MAX.13.5 56.5

61.6[68.6]
61.6[68.6]

-+ -+ -+ -+ -+ -+

46.2
46.2

A A A A
33

33
24.5

25
B B B B

6 1
8.5

8.5

Flow control
equipment
(Pitch) (Pitch)
24.5 P = 17 1/8 29 P = 16 One-touch fitting
(A, B port) (A, B port)
Applicable tubing
O.D.: ø6,ø1/4"

control equipment
Filter, Pressure
∗ Other dimensions are the same as the grommet type.

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)

94.4

Fittings & Tubing


61.6[68.6] 86.9
M8 x 1 66.1
0.6
0.6

75.6
46.2
0.6

0.6

48.6 0.6
0.6
74.5[76.7]

64.7[66.9]

84.5
83.6

73.6
107[111.4]

87.4[91.8]
103.4[107.8]

66.2
123[127.4]

125.2

105.2

90.4
127
141.2

121.2

106.4
143

Air preparation
equipment

Approx. 300 72.7[79.7]


(Lead wire length)
(Lead wire length)

MAX.10

Pg7
Pressure switch

Applicable cable O.D


Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.


Clean gas filter

A, B port size Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 66 83 100 117 134 151 168 185 202 219 236 253 270 287 304 321 338 355 372
1/8
L2 53 70 87 104 121 138 155 172 189 206 223 240 257 274 291 308 325 342 359
L1 65 81 97 113 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353
C6/N7
L2 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340

533
Manifold specifications 10-SYJ5000
C4
Type 43: Side ported / 10-SS5YJ5-43- Stations - N3 첸 ∗ [ ]: AC

Grommet (G)
(Lead wire length)
Approx. 300

L1
4.5 L2 Manual override

2-ø5.5
(For mounting)
12 1/8
(P, R port)
62.6[64.8]

62[64.2]
(DIN: 4.3) (DIN: 41.1)
(DIN: 41.7)

87.2[91.6]
103.2[107.6]

R
B B B B B
40.5

17.5
36.9
3.1 39.9
1.1 20.2
P

P
A A A A A

11.4
(4.4)
18.5
(DIN: 19.7)

(Pitch)
18 P = 16

Built-in speed controller


(Station 1) (Station n)
MAX.13.5 47.5
(Light/surge voltage suppressor)
52.6[59.6]

-+ -+ -+
37.2

A A
24
18

B B
6

(Pitch)
22.3 P = 16 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4,ø5/32"

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
85.4
52.6[59.6] 77.9
66.6 M8 x 1 57.1
0.6
0.6

37.2
39.6
0.6

0.6

0.6
0.6
72[74.2]

62.2[64.4]

81.1

82

63.7
71.1
125.2

90.4
127
107[111.4]

141.2

106.4
87.4[91.8]

105.2
143
123[127.4]

103.4[107.8]

121.2
1

Approx. 300 63.7[70.7]


(Lead wire length)
(Lead wire length)

Pg7
MAX.10

Applicable cable O.D


Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340
L2 43 59 75 91 107 123 139 155 171 187 203 219 235 251 267 283 299 315 331

534
Manifold specifications 10-SYJ5000

Flat ribbon cable manifold ∗ [ ]: AC

10-SS5YJ5-20P- Stations -00첸

Air cylinder
C4, N3
Manual override C6, N7
L1
M5 x 0.8 L2 9 (With built-in One-touch fitting)

Rotary actuator
(A, B port) 4-ø4.5
-+

(For mounting)
13.4

-+ -+

2.5 2.5 12.5

15.2
2
123[127.4]

107[111.4]
10 18.5

23.5
R

R One-touch fitting

16.5 16.5
A

A
45.6

(A, B port)
77.6 [79.8]

45

49
77 [79.2]
P

Applicable tubing

65
82.8
16.5
B

O.D.: ø4, ø5/32"

Air gripper
R

ø6, ø1/4"

-+ -+ -+ -+ -+

Triangle mark
1/8 (3.2) 52.8
(Pitch)
P = 17.5 21 (P, R port)

Directional control
(Station n) (Station 1)
(Light/surge voltage suppressor)

valve
48.6[55.6]

5.8
25.1
20

Applicable connector: 28.5

Flow control
26 pins MIL type with strain relief Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations

equipment
(Conforming to MIL-C-83503) L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 59 76.5 94 111.5 129 146.5 164 181.5 199 216.5

10-SS5YJ5-41P- Stations -M5첸


(Pitch)

control equipment
M5 x 0.8

Filter, Pressure
5.5

P = 17.5 26
(A, B port)
18.5

Built-in speed controller

Fittings & Tubing


L1
Manual override L2 7.5
-+

-+ -+
5.5
3.5
38.1 20.9

12
123[127.4]

7
107[111.4]
17.5

A A A A A
Air preparation

5.5
37.5

equipment
69.5 [71.7]
70.1 [72.3]

21
35
51

MAX.13.5
68.8

B B B B B

-+ -+ -+ -+ -+

2-ø5.5 Triangle mark 1/8


(For mounting) (Pitch) (P, R port)
Pressure switch

P = 17.5 21

(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6[59.6]

7.8
29.1

Clean gas filter


24

Applicable connector: 28.5


26 pins MIL type with strain relief Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations
(Conforming to MIL-C-83503) L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 62 79.5 97 114.5 132 149.5 167 184.5 202 219.5

535
Manifold specifications 10-SYJ5000

Flat ribbon cable manifold ∗ [ ]: AC

C4
10-SS5YJ5-43P- Stations - N3 첸
One-touch fitting (Pitch)
(A, B port) P = 17.5 25.3

6
Applicable tubing
O.D.: ø4, ø5/32"

18
L1 Built-in speed controller
Manual override L2 7.5
-+

-+ -+

(4.4)
11.4
12
3.1
1.1
40.5 18.5
123 [127.4]

107 [111.4]
20.2

A A A A A

5.5

36.9
39.9

17.5
71.9 [74.1]
72.5 [74.7]

52.9

MAX.13.5

70.7
B B B B B

-+ -+ -+ -+ -+

4-ø5.5 Triangle mark 1/8


(For mounting) (Pitch) (P, R port)
P = 17.5 21

(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6 [59.6]

7.8
29.1
24

Applicable connector: 28.5


26 pins MIL type with strain relief
(Conforming to MIL-C-83503)

Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations


L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 62 79.5 97 114.5 132 149.5 167 184.5 202 219.5

536
Series10-SYJ7000
Rubber seal
5 port solenoid valve

Air cylinder
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure
2 position double 0.1 to 0.7
range (MPa)
3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (with no freezing. Refer to page 714.)

Rotary actuator
Response time ms 2 position single, double 30 or less
(0.5MPa) Note 1) 3 position 60 or less
Max. operating 2 position single, double 5
frequency (Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the pilot and main valve
Body ported Lubrication Not required
Mounting orientation Unrestricted

Air gripper
Impact/Vibration resistance m/s2 Note 2) 150/30
Enclosure Dustproof (∗DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature : 20°C, at rated voltage,
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction

Directional control
and at the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep between 45 and 2000Hz. Test was

valve
performed in the axial direction and at the right angles to the main valve and armature in both
energized and de-energized states every once for each condition. (Value in the initial state)

Base mounted
Solenoid specifications

Flow control
equipment
JIS Symbol
Body ported Base mounted Grommet (G), (H)
2 position single 2 position single solenoid
L plug connector (L)
M plug connector (M)
(A)(B) (B)(A) Electrical entry
4 2 2 4 DIN terminal (D)
M8 connector (W)

control equipment
Filter, Pressure
5 1 3 3 1 5 G, H, L, M, W D
(R1) (P) (R2) (R2) (P) (R1)
DC 24, 12, 6, 5, 3 24, 12
Coil rated voltage V
2 position double 2 position double solenoid AC 50/60Hz 100, 110, 200, 220
(A)(B) (B)(A) Allowable voltage fluctuation ±10% of rated voltage ∗
4 2 2 4
Standard 0.35 {With indicator light: 0.4 (DIN connector with indicator light: 0.45)}
Power consumption (W) DC
With power saving circuit 0.1 (With indicator light only)
5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1) 100V 0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)

Fittings & Tubing


110V 0.86 (With indicator light: 0.89) 0.86 (With indicator light: 0.97)
3 position closed center 3 position closed center
∗ [115V] [0.94 (With indicator light: 0.97)] [0.94 (With indicator light: 1.07)]
(A)(B) (B)(A) Apparent power (VA) AC
4 2 2 4 200V 1.18 (With indicator light: 1.22) 1.15 (With indicator light: 1.30)
220V 1.30 (With indicator light: 1.34) 1.27 (With indicator light: 1.46)
5 1 3 3 1 5 [230V] [1.42 (With indicator light: 1.46)] [1.39 (With indicator light: 1.60)]
(R1) (P) (R2) (R2) (P) (R1) Surge voltage suppressor Diode (DIN terminal, varistor for non-polar type)
3 position exhaust center 3 position exhaust center Indicator light LED (Neon light when AC with DIN terminal)
(A)(B) (B)(A) ∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
Air preparation

4 2 2 4
equipment

∗ For 115 and 230 VAC, the allowable voltage fluctuation is -15% to +5% of rated voltage.
∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please observe the
5 1 3 3 1 5 following range because they have voltage drop due to internal circuit.
(R1) (P) (R2) (R2) (P) (R1) S and Z types 24 VDC: –7% to +10%
12 VDC: –4% to +10%
3 position pressure center 3 position pressure center T type 24 VDC: –8% to +10%
(A)(B) (B)(A) 12 VDC: –6% to +10%
4 2 2 4
Pressure switch

5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1)

Made to
Order Made to order specifications (Refer to page 557 for details.)
Clean gas filter

537
5 port solenoid valve Series 10-SYJ7000

Flow characteristics / Weight


Port size Flow characteristicsNote 1) Weight (g)Note 2, 3)
Valve model Type of actuation 1,5,3 4,2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB) L/M plug DIN M8
Grommet
(P,EA,EB) (A,B) C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv connector terminal connector
Single 85 86 107 90
2 position 2.2 0.36 0.58 2.4 0.34 0.63
Double 98 100 142 108
10-SYJ7첸23-첸-01 Closed center 1/8 1/8 1.8 0.37 0.45 2.0 0.35 0.49
3 position Exhaust center 1.2 0.50 0.34 3.0[1.3] 0.35[0.52] 0.73[0.39] 108 110 152 118
Pressure center 3.0[0.83] 0.37[0.50] 0.78[0.25] 1.8 0.37 0.45
Single 96 97 98 101
Body ported

2 position 1.6 0.33 0.4 2.2 0.32 0.53


Double C6 109 111 153 119
10-SYJ7첸23-첸-C6 Closed center 1/8 (One-touch 1.4 0.27 0.35 1.9 0.33 0.49
3 position Exhaust center fitting for ø6) 1.1 0.37 0.27 2.5[1.3] 0.32[0.54] 0.61[0.38] 119 121 163 129
Pressure center 1.8[0.78] 0.36[0.40] 0.45[0.22] 1.6 0.30 0.39
Single 96 97 98 101
2 position 2.0 0.39 0.52 2.3 0.34 0.61
Double C8 109 111 153 119
10-SYJ7첸23-첸-C8 Closed center 1/8 (One-touch 1.7 0.35 0.42 2.0 0.29 0.49
3 position Exhaust center fitting for ø8) 1.2 0.38 0.33 2.6[1.3] 0.35[0.49] 0.67[0.38] 119 121 163 129
Pressure center 1.9[0.86] 0.57[0.46] 0.59[0.25] 1.7 0.39 0.42
Single 165(85) 166(86) 187(107) 170(90)
2 position 2.3 0.45 0.57 2.8 0.37 0.71
Double 178(98) 180(100) 222(142) 188(108)
10-SYJ7첸43-첸-01 Closed center 1/8 1/8 1.9 0.36 0.48 2.1 0.46 0.57
Base mounted

3 position Exhaust center 1.2 0.48 0.35 3.4[1.3] 0.36[0.57] 0.86[0.41] 188(108) 190(110) 232(152) 198(118)
Pressure center 3.3[0.85] 0.43[0.54] 0.78[0.25] 2.1 0.45 0.56
Single 165(85) 166(86) 187(107) 170(90)
2 position 2.3 0.41 0.61 2.9 0.35 0.74
Double 178(98) 180(100) 222(142) 188(108)
10-SYJ7첸43-첸-02 Closed center 1/4 1/4 1.9 0.46 0.50 2.2 0.44 0.60
3 position Exhaust center 1.3 0.45 0.35 3.7[1.4] 0.27[0.56] 0.87[0.43] 188(108) 190(110) 232(152) 198(118)
Pressure center 3.6[0.83] 0.23[0.55] 0.84[0.25] 2.1 0.47 0.58
Note 1) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate
Note 3) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types.

538
5 port solenoid valve Series 10-SYJ7000

How to Order
Light/Surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Type of actuation

Air cylinder
Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
1 2 position single solenoid S With surge voltage suppresser S With surge voltage suppresser (Non-polar type)
2 2 position double solenoid Z With light/surge voltage suppresser Z With light/surge voltage suppresser (Non-polar type)
3 3 position closed center R With surge voltage suppressor (Non-polar type) ∗ "DOZ" is not available.
∗ For AC voltage valves, there is
Bracket
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
no "S" option. It is already built-
5 3 position pressure center ∗ For AC voltage valves, there is no "S" option. It is Nil: Without bracket
in to the rectifier circuit.
already built-in to the rectifier circuit. F: With bracket

Rotary actuator
∗ For "R" and "U", DC voltage is only available.
∗ Power saving circuit is only available in the "Z" Thread type
type.
Nil Rc
F G
Rated voltage
N NPT
DC specifications AC specifications (50/60Hz)
T NPTF
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC [115 VAC] 01 1/8

Air gripper
Note) Do not remove the factory
S 5 VDC 4 220 VAC [230 VAC] C6 One-touch fitting for ø6 installed bracket from
R 3 VDC ∗ For type "W첸", C8 One-touch fitting for ø8 models with the bracket
∗ DC specifications of option. Removal of the
DC voltage is N7 One-touch fitting for ø1/4" bracket will cause the
type "D" and "DO" is only available.
only available with N9 One-touch fitting for ø5/16" valve to leak. Brackets
(For manifold type 20, 21) 12 and 24 V DC. cannot be retrofitted.

Directional control
Body ported 10 SYJ7 1 23 5 M 01

valve
Base mounted 10 SYJ7 2 43 5 M

Flow control
Thread type

equipment
Nil Rc
Coil specifications Manual override F G
Nil Standard N NPT
Nil: Non-locking push
With power saving circuit type T NPTF
T
<For 24 and 12 VDC only>

control equipment
∗ Power saving circuit is

Filter, Pressure
Sub-plate, 40, 41, 42
not available in the
manifold Port size
case of "D", "DO" or
"W첸" type. Nil: Without sub-plate

D: Push-turn locking
slotted type

Fittings & Tubing


Electrical entry (With gasket and screws)

24, 12 VDC, 24, 12 VDC, 01: 1/8 with sub-plate Note)


24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC
100, 110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector DIN terminal M8 connector
E: Push-turn locking
Air preparation

G: Lead wire L: With lead M: With lead wire MN: Without D: With connector WO: Without
equipment

length wire (length (length 300 mm) lead wire connector lever type
300 mm 300 mm)
+- +-

-+ 02: 1/4 with sub-plate


-+

Pressure switch

H: Lead wire LN: Without LO: Without MO: Without DO: Without W첸: With connector
length 600 mm lead wire connector connector connector cable Note 1)

Note 1) Be sure to enter a


symbol of the
-+
-+

cable length with Note) R1, R2 ports :


Clean gas filter

reference to page 1/4


562.
∗ "LN", "MN" type : with 2 sockets.
∗ DIN terminal type "Y" conforming to EN-175301-803C (former DIN43650C) is also available. For
details, refer to page 557.
∗ For connector cable of M8 connector, refer to page 562.

539
5 port solenoid valve Series 10-SYJ7000

How to Order Pilot Valve Assembly

10 V111 5 G 10 V115 5 D
Clean series Clean series
Light/Surge voltage suppressor
Coil specifications Without light/surge voltage suppressor
Rated voltage
Nil
Nil Standard 5 24 VDC
S With surge voltage suppressor
With power saving circuit 6 12 VDC
T Z With light/surge voltage suppressor Light/surge voltage suppressor
<24 and 12 VDC only> 1 100 VAC 50/60Hz
R With surge voltage suppressor (Non-polar type) 2 200 VAC 50/60Hz Nil Without light/surge voltage suppressor
∗ Power saving circuit is U With light/surge voltage suppressor (Non-polar type) 110 VAC 50/60Hz S With surge voltage suppressor (Non-polar type)
not available in the 3
∗ For AC voltage valves, there is no [115 VAC 50/60Hz] Z With light/surge voltage suppressor (Non-polar type)
case of "W첸" type.
"S" option. It is already built-in to 4 220 VAC 50/60Hz ∗ "DOZ" is not available.
the rectifier circuit. [230 VAC 50/60Hz] ∗ For AC voltage valves, there
Rated voltage ∗ For "R" and "U", DC voltage is only is no "S" option. It is already
5 24 VDC available. built-in to the rectifier circuit.
∗ Power saving circuit is only available
6 12 VDC
in the "Z" type.
V 6 VDC
S 5 VDC
R 3 VDC Electrical entry Electrical entry
1 100 VAC 50/60Hz G Grommet (Lead wire length 300 mm) D With connector
DIN
2 200 VAC 50/60Hz H Grommet (Lead wire length 600 mm) DO terminal Without connector
110 VAC 50/60Hz L With lead wire
3 Note) Do not replace 10-V111
[115 VAC 50/60Hz] L plug
LN
connector Without lead wire (G, H, L, M, W) to 10-
220 VAC 50/60Hz LO Without connector V115 (DIN terminal) and
4
[230 VAC 50/60Hz] M With lead wire vice versa when
∗ For type "W첸", DC M plug replacing pilot valve
MN
voltage is only connector Without lead wire Note 1) Be sure to enter a assembly only.
MO Without connector symbol of the cable
available.
WO M8 Without connector cable length with reference
W첸 connector With connector cable Note 1) to page 562.
∗ For connector cable of M8
connector, refer to page 562.

How to Order L/M Plug Connector Assembly How to Order M8 Connector Cable

For DC :SY100-30-4A-
V100-49-1-
For 100 VAC :SY100-30-1A-
For 200 VAC :SY100-30-2A- Cable length
1 300mm
For other voltages of AC :SY100-30-3A- 2 500mm
3 1000mm
Without lead wire 4 2000mm
(With connector and 2 of sockets only) :SY100-30-A 7 5000mm

Lead wire length


Nil 300mm
6 600mm
10 1000mm
15 1500mm
20 2000mm
25 2500mm
30 3000mm
50 5000mm

540
5 port solenoid valve Series 10-SYJ7000

2 position single ∗ [ ]: AC

Grommet (G), (H): 10- SYJ7123-첸GH 첸첸-01첸 With bracket


10-SYJ7123-첸GH 첸첸-01첸-F

Air cylinder
44
2-ø4.5 36 4
(For mounting)

26
34
- +
G: Approx. 300
82[84.2] H: Approx. 600

Rotary actuator
59.8 (Lead wire length) 24.1
28.3 39.5[46.5]
13
3

A B

Manual override
2-ø3.2 17
(For manifold mounting) 1/8

85.6[87.8]
35 (A, B port)

Air gripper
2-ø3.2 (Light/surge voltage suppressor)
35
(For mounting) (Bracket)

3.6
-+
28
25

16.1
21

Directional control
31.5[38.5]

valve
Built-in One-touch fitting:
10-SYJ7123-첸GH 첸첸- C6, N7
C8, N9 첸 (-F)
R1 P R2
28.3
1.6
18

1/8 27.2 A B
(P, R1, R2 port)

Flow control
equipment
17
One-touch fitting
(4.9)

(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
: ø8, ø5/16"

control equipment
36

Filter, Pressure
(3.6)

L plug connector (L) M plug connector (M) DIN Terminal (D): M8 connector (WO):

Fittings & Tubing


10-SYJ7123-첸L첸첸-01첸 (-F) 10-SYJ7123-첸M첸첸-01첸 (-F) 10-SYJ7123-첸D첸첸-01첸 (-F) 10-SYJ7123-첸WO첸첸-01첸 (-F)
Applicable cable O.D.
Approx. 300 (Lead wire length)

ø3.5 to ø7
65
31.5[38.5]
MAX.10

57.5
16.1 46.2
31.1 M8 x 1 36
Air preparation
equipment

(Lead wire length) 18.5


Approx. 300 42.6[49.6]

Pg7
91.9[94.1]

101.9
82.1[84.3]

101

Pressure switch
91
83.6
77.1

61.1
35

35

35

35
28.3

28.3

28.3

28.3

21 21 21 21
(3.6)

(3.6)

(3.6)

(3.6)

2-ø3.2 2-ø3.2 2-ø3.2 2-ø3.2


25 25 25 25
Clean gas filter

(For mounting) (For mounting) (For mounting) (For mounting)


28 28 28 28

∗ Refer to page 563 for dimensions with connector cable.

541
5 port solenoid valve Series 10-SYJ7000

2 position double ∗ [ ]: AC

Grommet (G), (H): 10-SYJ7223-첸GH 첸첸-01첸 Built-in One-touch fitting:


10-SYJ7223-첸GH 첸첸- C6, N7
C8, N9 첸

G: Approx. 300
107.4[111.8] H: Approx. 600
63 (Lead wire length)
3
13

A B A B

Manual override
17 17
2-ø3.2 35 1/8 (A, B port)
(For manifold mounting)
One-touch fitting

(4.9)
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"

36
-+
28
25

16.1
21

31.5[38.5]
1.6

R1 P R2
18

1/8 (P, R1, R2 port) 27.2

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7223-씲L씲씲-01씲 10-SYJ7223-씲M씲씲-01씲 10-SYJ7223-씲D씲씲-01씲 10-SYJ7223-씲WO씲씲-01씲
(Lead wire length)
Approx. 300

65
31.5[38.5]
MAX.10

57.5
16.1 46.2
31.1 M8 x 1 36
Approx. 300 42.6[49.6] 18.5
(Lead wire length)

2-ø3.2
(For mounting) 2-ø3.2
127.2[131.6]

2-ø3.2 (For mounting) 2-ø3.2


107.6[112]

(For mounting) (For mounting)


145.4

147.2

125.4
110.6
97.6

65.6
35

35

35

35

21
21
21 25
21 25
28 Pg7
25 25 28
Applicable cable O.D.
28 28
ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

542
5 port solenoid valve Series 10-SYJ7000

3 position closed center / Exhaust center / Pressure center ∗ [ ]: AC


3
Grommet (G), (H): 10-SYJ7 45 23-첸 GH 첸첸-01첸 Built-in One-touch fitting:
3
10-SYJ7 45 23-첸GH 첸첸- C6, N7
C8, N9 첸

Air cylinder
G: Approx. 300
122[126.4] H: Approx. 600
(Lead wire length)

Rotary actuator
54.5[56.7]
45.3 32.3
3
13

A B A B

Manual override
17 17
2-ø3.2 1/8 (A, B port)
(For manifold mounting) 35
One-touch fitting

(4.9)

Air gripper
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"

36
- +
28
25

16.1
21

Directional control
31.5[38.5]

valve
1.6

R1 P R2
18

1/8 (P, R1, R2 port) 27.2

Flow control
equipment
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3 3
10-SYJ7 45 23-첸L첸첸-01첸 10-SYJ7 45 23-첸M첸첸-01첸 10-SYJ7 45 23-첸D첸첸-01첸 10-SYJ7 45 23-첸WO첸첸-01첸
(Lead wire length)
Approx. 300

65
31.5[38.5]
MAX.10

57.5
16.1

Fittings & Tubing


46.2
31.1 M8 x 1 36
Approx. 300 42.6[49.6] 18.5
(Lead wire length)
64.4[66.6]

74.4
54.6[56.8]

73.5

63.5
56.1
49.6

Air preparation
33.6

equipment
141.8[146.2]

122.2[126.6]
35

35

35

35
161.8
160

140
46.6
62.6

2-ø3.2 21 2-ø3.2 21 2-ø3.2 21 2-ø3.2 21


69.1

(For mounting) 25 (For mounting) 25 (For mounting) 25 (For mounting) 25


Pressure switch

28
28
28
Pg7 28
Clean gas filter

Applicable cable O.D.


ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

543
5 port solenoid valve Series 10-SYJ7000

2 position single ∗ [ ]: AC

Grommet (G), (H): 10- SYJ7143-첸 GH 첸첸- 01


02 첸

22

12
34 8.5
2-ø4.3
Manual override B A (For mounting)

27
A
B
R2 P R1

G: Approx. 300 59.8 3.2


H: Approx. 600 85.2[87.4]
(Lead wire length)

(Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port)


57.5[64.5]

- +

54
42.1
25.5

20
12
11.5
18 1/4 (R1, R2 port) 22 22
34 31.5
63

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7143-첸L첸첸- 0102 첸 10-SYJ7143-첸M첸첸- 0102 첸 10-SYJ7143-첸D첸첸- 01
02 첸 10-SYJ7143-첸WO첸첸- 01
02첸
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7

91
MAX.10

57.5[64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
44.5
68.6[75.6] Approx. 300

20 20 20 20
Pg7
95.1[97.3]

104.2
85.3[87.5]

94.2
86.8
80.3
22

22

22

22
64.3
63

63

63

63
22

22

22

22
31.5

31.5

31.5

31.5
3.2

3.2
3.2

3.2

11.5 11.5 11.5 11.5


12 12 12 12
25.5 25.5 25.5 25.5

∗ Refer to page 563 for dimensions with connector cable.

544
5 port solenoid valve Series 10-SYJ7000

2 position double ∗ [ ]: AC

Grommet (G), (H): 10-SYJ7243-첸GH 첸첸- 01


02첸

Air cylinder
22

12

Rotary actuator
G: Approx. 300
H: Approx. 600 107.4[111.8]
(Lead wire length) 63

Air gripper
B A

27
A
B
Manual override R2 P R1

2-ø4.3 34 8.5
(For mounting)

Directional control
(Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port)

valve
57.5[64.5]

- +
42.1
25.5

20
12
11.5

22 22

Flow control
18 1/4 (R1, R2 port)

equipment
34 31.5
63

control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7243-첸L첸첸- 0102첸 10-SYJ7243-첸M첸첸- 0102 첸 10-SYJ7243-첸D첸첸- 01
02 첸 10-SYJ7243-첸WO첸첸- 01
02첸

Applicable cable O.D.


(Lead wire length)

Fittings & Tubing


ø3.5 to ø7
Approx. 300

91
57.5[64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
68.6[75.6] Approx. 300 44.5
Air preparation
equipment

20 20 20 20
Pg7
127.2[131.6]

107.6[112]
22

22 22

22
22

147.2

145.4

110.6
125.4
97.6

65.6
63

63

63
63

22

22
22

31.5

31.5

31.5
31.5

Pressure switch

11.5 11.5 11.5 11.5


12
12 12 12
25.5
25.5 25.5 25.5
MAX.10

Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

545
5 port solenoid valve Series 10-SYJ7000

3 position closed center / Exhaust center / Pressure center ∗ [ ]: AC

3
Grommet (G), (H): 10-SYJ7 45 43-첸 GH첸첸- 01
02 첸

22

12
G: Approx. 300
H: Approx. 600 122[126.4]
(Lead wire length) 2-ø4.3 36[38.2]
(For mounting)
B A

27
A
B
R2 P R1
Manual override 34 8.5
63.8 13.8

(Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port)


57.5[64.5]

- +
42.1
25.5

20
12
11.5

18 1/4 (R1, R2 port) 22 22


34 31.5
63

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3 3
10-SYJ7 45 43-첸L첸첸- 01
02 첸 10-SYJ7 45 43-첸M첸첸- 01
02 첸 10-SYJ7 45 43-첸D첸첸- 01
02첸 10-SYJ7 45 43-첸WO첸첸- 01
02첸
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Approx. 300

91
57.5[64.5] 83.5
42.1 72.2
Pg7 62 M8 x 1
(Lead wire length) 57.1
68.6[75.6] Approx. 300 44.5

20 20 20 20
141.8[146.2]

87.6
122.2[126.6]
81.1
22

22

22 22

22
65.1
161.8
63

63

63

63
160

140
22

22

22
31.5

31.5

31.5

31.5
15.1
45.9[48.1]

31.1

11.5 11.5 11.5 11.5


37.6
45
55.9

12 12 12 12
55

25.5 25.5 25.5 25.5


36.1[38.3]

MAX.10

∗ Refer to page 563 for dimensions with connector cable.

546
Series 10-SYJ7000 Manifold specifications

Air cylinder
Manifold standard

Manifold specifications

Model Type 20 Type 21 Type 40 Type 41 Type 42

Rotary actuator
Manifold type Single base / B mount
P (SUP) / R (EXH) Common SUP / Common EXH
Valve stations 2 to 15 stations 2 to 20 stations
A, B port porting Location Valve Base Base
specifications Direction Top Bottom Side
P, R port 1/8 1/4

Air gripper
1/8 C6 (One-touch
Port size A, B port C6 (One-touch fitting for ø6) 1/8 fitting for ø6)
C8 (One-touch fitting for ø8) C8 (One-touch
fitting for ø8)

Directional control
Flow characteristics

valve
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 1/8 2.2 0.35 0.57 2.3 0.26 0.55
Body

Flow control
equipment
ported
10-SS5YJ7-20 1/8 C6 1.4 0.32 0.37 2.0 0.25 0.49
for
10-SYJ7첸23 1/8 C8 1.7 0.38 0.45 2.1 0.25 0.51
1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
internal
pilot
10-SS5YJ7-21 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Base 10-SS5YJ7-40 1/4 1/8 2.1 0.28 0.51 2.5 0.23 0.59

control equipment
mounted 10-SS5YJ7-41 10-SYJ7첸43 1/4 1/8 2.0 0.30 0.50 2.2 0.30 0.55

Filter, Pressure
for internal 10-SS5YJ7-42-C6 1/4 C6 1.5 0.32 0.38 2.2 0.23 0.52
pilot 10-SS5YJ7-42-C8 1/4 C8 1.9 0.24 0.46 2.2 0.26 0.53
Note) Value at manifold base mounted, 2 position single operating

Fittings & Tubing


How to Order Manifold
Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model number.
Example 앬 10-SS5YJ7-20-03 ········ 1 set (Manifold base)
∗ 10-SYJ7123-5G-01 ······· 2 sets (Valve)
∗ SYJ7000-21-1A ············ 1 set (Blanking plate assembly)
Air preparation
equipment

앬 10- SS5YJ7-41-03-01 ·· 1 set (Manifold base)


∗ 10- SYJ7143-5LZ ·········· 1 set (Valve)
∗ 10- SYJ7243-5LZ ·········· 1 set (Valve)
∗ SYJ7000-21-1A ············ 1 set (Blanking plate assembly)

The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the
Pressure switch

solenoid valve, etc.


∗ Use manifold specification sheet.
Clean gas filter

547
Manifold specifications 10-SYJ7000

Flat ribbon cable manifold

• Multiple valve wiring is Flat ribbon cable manifold specifications


simplified through the
Model Type 21P
use of the flat ribbon Manifold type Single base / B mount
cable connector. P(SUP) / R(EXH) Common SUP / Common EXH
Valve stations 3 to 12 stations
• Clean appearance A, B port porting specifications Valve
In the case of a flat ribbon cable type, each valve P, R port 1/4
is wired on the print board of manifold base to
Port size
A, B port 1/8, C6, C8
allow the external wiring to be piped all together
with 26 pins MIL connector. Applicable flat ribbon Socket: 26 pins MIL type with strain relief (Conforming to MIL-C-83503)
cable connector (MIL-C-83503 compliant)
Internal wiring In common between +COM and –COM (Z type: +COM only)
Rated voltage 24, 12 VDC
Note) The value is for manifold base and individually operated 2 position type.
Note 2) The withstand voltage specification for the wiring unit section is JIS C0704, Grade 1 or its equivalent.

Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
Body ported 10-SS5YJ7-21P-01 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
for internal 10-SS5YJ7-21P-C6 10-SYJ7첸23 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
pilot 10-SS5YJ7-21P-C8 1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model number.
(Example) 앬 10-SS5YJ7-21P-07 ···· 1 set (Manifold base)
∗ 10-SYJ7123-5LOU-C8 ·····3 sets (Valve)
∗ 10-SYJ7223-5LOU-C8 ·····3 sets (Valve)
∗ SYJ7000-21-3A ····· 1 set (Blanking plate assembly)
∗ SY3000-37-3A ······ 3 sets (Connector assembly)
∗ SY3000-37-4A ······ 3 sets (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
∗ Use manifold specification sheet.

How to Order Valve How to Order Connector Assembly


Light/Surge voltage suppressor
Rated voltage Z With light/surge voltage suppressor 12V, 24 VDC
5 24 VDC With light/surge voltage For single solenoid SY3000-37-3A
U
6 12 VDC suppressor (Non-polar type) For double solenoid 3 position type SY3000-37-4A
Note) Z: Positive common specifications only. For single solenoid, individual SUP/EXH spacer SY3000-37-3A
For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-6A
For DC10 SYJ7 1 23 5 LO Z 01 3 port adaptor plate SY3000-37-3A
100 VAC
For single solenoid SY3000-37-32A
For AC10 SYJ7 1 23 1 LOZ 01 For double solenoid 3 position type SY3000-37-33A
For single solenoid, individual SUP/EXH spacer SY3000-37-15A
For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-34A
Type of actuation A, B port size 3 port adaptor plate SY3000-37-32A
1 2 position single Symbol Port size
2 2 position double 01 1/8
100 VAC (115 VAC)
3 3 position closed center C6 One-touch fitting for ø6 For single solenoid SY3000-37-35A
4 3 position exhaust center C8 One-touch fitting for ø8 For double solenoid 3 position type SY3000-37-36A
5 3 position pressure center N7 One-touch fitting for ø1/4" For single solenoid, individual SUP/EXH spacer SY3000-37-19A
N9 One-touch fitting for ø5/16" For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-37A
Rated voltage 3 port adaptor plate SY3000-37-35A
1 100 VAC
3 110 VAC (115 VAC)
Note) In the case of flat ribbon cable
Manual override type, "U" and "Z" types are for DC
specifications and "Z" type is for
Nil Non-locking push type AC specifications. "Z" type for DC
D Push-turn locking slotted type is positive common specifications
E Push-turn locking lever type only. For other combinations,
please contact SMC.

548
Manifold specifications 10-SYJ7000
Manifold standard
Common SUP / Common EXH
Type 20 (5 port / Body ported) How to Order
A, B port 10-SS5YJ7-20- 05 -

Air cylinder
P,R port
thread type
Stations
Nil Rc
02 2 stations Applicable solenoid valve
00F G 01
P port 1/8 : : 10-SYJ7첸23-첸첸첸첸-C6
00N NPT C8
15 15 stations 00T NPTF
R port 1/8
Applicable blanking

Rotary actuator
Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
plate assembly
Type 21 (5 port / Body ported) How to Order SYJ7000-21-1A
A, B port 10-SS5YJ7-21- 05 - Applicable individual
P,R port EXH spacer assembly
Stations thread type
02 2 stations SYJ7000-17-1A
Nil Rc
P port 1/4 : :
00F G
20 20 stations

Air gripper
00N NPT
R port 1/4 00T NPTF
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 40 (5 port / Base mounted) How to Order


P port 1/4 10-SS5YJ7-40- 05 - 01

Directional control
Stations A, B port size Thread type
02 2 stations 01 1/8 Nil Rc

valve
: : F G
R port 1/4 N NPT
20 20 stations
T NPTF
A, B port 1/8
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port. Applicable solenoid valve
Type 41 (5 port / Base mounted) How to Order 10-SYJ7첸43-첸첸첸첸

Flow control
10-SS5YJ7-41- 05 - 01

equipment
Applicable blanking
plate assembly
P port 1/4 Stations A, B port size Thread type SYJ7000-21-1A
02 2 stations 01 1/8 Nil Rc Applicable individual
: : F G EXH spacer assembly
N NPT SYJ7000-17-2A
20 20 stations

control equipment
Filter, Pressure
A, B port 1/8 T NPTF
R port 1/4 Applicable individual
Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. SUP spacer assembly
Type 42 (5 port / Base mounted) How to Order SYJ7000-16-2A
10-SS5YJ7- 42- 05 - C6
Stations A, B port size Thread type
02 2 stations C6 One-touch fitting for ø6 Nil Rc

Fittings & Tubing


P port 1/4 F G
: : C8 One-touch fitting for ø8
20 20 stations N7 One-touch fitting for ø1/4" N NPT
A, B port T NPTF
C6, C8 R port 1/4 N9 One-touch fitting for ø5/16"
Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. Air preparation
equipment

Flat ribbon cable manifold


Common SUP / Common EXH
Applicable solenoid valve
Type 21P (5 port / Body ported) How to Order Refer to page 548.
10-SS5YJ7-21P - 05 -
Pressure switch

A, B port
Applicable blanking
Stations P, R port plate assembly
thread type SYJ7000-21-3A
P port 1/4 03 3 stations
Nil Rc
: : Applicable connector
00F G
12 12 stations 00N NPT assembly
00T NPTF Refer to page 548.
Clean gas filter

R port 1/4
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

549
Manifold specifications 10-SYJ7000

<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base Mix installation of 10-SYJ700 and 10-SYJ7000 valves on the same manifold
Round head combination screw Round head combination screw 앬 Use of an adapter plate makes it possible to mount series 10-SYJ700 on the manifold bases of
M3 x 31 series 10-SYJ7000.
M3 x 31
앬 When mounting the 10-SYJ700 valve on the 10-SYJ7000 manifold, the 10-SYJ700 solenoid
Matt nickel plated Matt nickel plated must be positioned on the same side of a single solenoid of the 10-SYJ7000.
(With spring washer) (With spring washer) 앬 For base mounted style, the A port of the 3 port valve become the B port of manifold base.

Adaptor plate assembly Adaptor plate assembly


SYJ700-3-1A SYJ700-3-2A
Series 10-SYJ700 body ported type Series 10-SYJ700 base mounted type

Gasket Gasket
DXT199-21-10 DXT199-21-11

Round head
Applicable base Applicable base combination screw
· 10-SS5YJ7-20 · Sub-plate Round head
· 10-SS5YJ7-21 · 10-SS5YJ7-40 combination screw
· 10-SS5YJ7-41
· 10-SS5YJ7-42
Individual EXH spacer assembly
SYJ7000-17-1 A Thread type
SYJ7000-17-2 A Thread type
Round head Nil Rc Round head Nil Rc
F G F G
Gasket
combination screw combination screw
N NPT N NPT
T NPTF T NPTF
Round head

7
Round head combination screw

7
combination screw
B
B

Adaptor plate Adaptor plate


A
A

O-ring
Manifold gasket
15
15

Individual R2 Individual R2
exhaust spacer exhaust spacer Applicable base Applicable base
· 10-SS5YJ7-20 · 10-SS5YJ7-40
R
R1 R1
R
· 10-SS5YJ7-21 · 10-SS5YJ7-41
· 10-SS5YJ7-42

Manifold Manifold
gasket gasket Blanking plate assembly
Applicable base Applicable base SYJ7000-21-1A
· 10-SS5YJ7-20 · 10-SS5YJ7-40
Round head combination screw
· 10-SS5YJ7-21 · 10-SS5YJ7-41
· 10-SS5YJ7-42
Individual SUP spacer assembly
SYJ7000-16-2 A Blanking plate Applicable base
· 10-SS5YJ7-20
Round head · 10-SS5YJ7-21
combination screw Gasket · 10-SS5YJ7-40
Thread type · 10-SS5YJ7-41
Nil Rc SYJ7000-21-3A · 10-SS5YJ7-42
F G
B

N NPT Round head


T NPTF combination screw
A

Blanking plate

Gasket
15

Individual
SUP spacer
P

Applicable base
Manifold Dust cap
· 10-SS5YJ7-40
gasket
· 10-SS5YJ7-41
Applicable base
· 10-SS5YJ7-42
Caution · 10-SS5YJ7-21P

Mounting screw tightening torque Use caution to the assembly orientation of solenoid valves, gasket, and optional parts.
M3: 0.8N·m
550
Manifold specifications 10-SYJ7000
Type 20: Top ported / 10-SS5YJ7-20- Stations -00 ∗ [ ]: AC

Grommet (G)
(Lead wire length)
Approx. 300

Air cylinder
L1 4-ø4.5
L2 6 (For mounting)

(DIN: 7.8)
(DIN: 21.6)

Rotary actuator
15.5
3

6.5
3.3
20.3

8
122[126.4]

107.4[111.8]
17 16.5
A

25
R

(DIN: 57.8)
(DIN: 58.6)

17 17
56.5

78.7[80.9]
57.3

50
79.5[81.7]

P
P

R
R

Air gripper
1/8 (P, R port)

1/8 (A, B port)


Manual override (Pitch)
P = 19 20

Directional control
Built-in One-touch fitting

valve
(Station n) (Station 1)

(Light/surge voltage suppressor) One-touch fitting


(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
55.5[62.5]

-+ -+ -+ -+ -+

Flow control
equipment
ø8, ø5/16"
40.1
23.5

control equipment
(4.9) 60

Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7

Fittings & Tubing


MAX.10

55.5[62.5] 89
40.1 Pg7 81.5
(Lead wire length)
70.2
Approx. 300 66.6[73.6] M8 x 1 Air preparation
equipment
3.3
3.3

3.3

3.3
161.8
141.8[146.2]

122.2[126.6]
127.2[131.6]

107.6[112]

125.2
160

140
145.4

147.2

125.4

110.6
78.8[81]
88.6[90.8]

80.3
87.7
97.7

98.6

Pressure switch
0.8

0.8

42.5
0.8
0.8

60
0.8

0.8

∗ Refer to page 563 for dimensions with connector cable.


Clean gas filter

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 stations


L1 59 78 97 116 135 154 173 192 211 230 249 268 287 306
L2 47 66 85 104 123 142 161 180 199 218 237 256 275 294

551
Manifold specifications 10-SYJ7000
Type 21: Top ported / 10-SS5YJ7-21- Stations (-00 ) ∗ [ ]: AC

Grommet (G)
(Lead wire length)
Approx. 300

L1
4-ø4.5
L2 10 (For mounting)

(DIN: 2.8)
(DIN: 16.6)

16.5
3 11.5
15.3

1.5
122[126.4]

107.4[111.8]
R
A

30
R

(DIN: 62.8)
(DIN: 63.6)

21
61.5

83.7[85.9]
62.3
84.5[86.7]

17

21

60
P
P

21
R
R

1/4 (P, R port)

Manual override (Pitch)


1/8 (A, B port)
P = 19 23.5
Built-in One-touch fitting

(Station n) (Station 1)

(Light/surge voltage suppressor)


One-touch fitting
(A, B port)
58.5[65.5]

-+ -+ -+ -+ -+
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
43.1
26.5

(4.9) 63

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
Applicable cable O.D.
(Lead wire length)
Approx. 300

ø3.5 to ø7
MAX.10

58.5[65.5] 92
84.5
43.1 Pg7
73.2
(Lead wire length)
Approx. 300 69.6[76.6] M8 x 1
141.8[146.2]

122.2[126.6]
127.2[131.6]

107.6[112]

161.8

125.2
160

140
145.4

125.4

110.6
83.8[86]

147.2
93.6[95.8]

85.3
92.7
102.7

103.6
0.8

0.8

45.5
0.8
0.8

63
0.8

0.8

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388

552
Manifold specifications 10-SYJ7000
Type 40: Bottom ported / 10-SS5YJ7-40- Stations -01 ∗ [ ]: AC

(Lead wire length)


Approx. 300
Grommet (G)
L1

Air cylinder
4-ø4.5
L2 10 (For mounting)

16.5

(DIN: 16.6)

(DIN: 2.8)
11.5

15.3
0.5

1.5

Rotary actuator
122[126.4]

107.4[111.8]
R
A A A A A
(DIN: 63.6)

30
R

(DIN: 62.8)

21 21
83.7[85.9]
84.5[86.7]
62.3

61.5
21

60
P
P

B B B B B

R
R

1/4 (P, R port)

Air gripper
Manual override (Pitch)
P = 19 23.5
(Station n) (Station 1)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+
58[65]

Directional control
42.6
26

valve
B B
19
40

Flow control
equipment
A A

1/8 (A, B port)

(Pitch) 2
23.5

control equipment
P = 19

Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
Applicable cable O.D.
(Lead wire length)
Approx. 300

ø3.5 to ø7
MAX.10

91.5

Fittings & Tubing


58[65]
84
42.6 Pg7
72.7
(Lead wire length)
Approx. 300 69.1[76.1] M8 x 1
Air preparation
141.8[146.2]

122.2[126.6]

equipment
127.2[131.6]

107.6[112]

161.8

125.2
160

140
145.4

147.2

125.4

110.6
83.8[86]
93.6[95.8]

85.3
92.7
102.7

103.6

Pressure switch
0.8

0.8

45
0.8

0.8

62.5
0.8
0.8

∗ Refer to page 563 for dimensions with connector cable.


Clean gas filter

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388

553
Manifold specifications 10-SYJ7000
Type 41: Side ported / 10-SS5YJ7-41- Stations -01 ∗ [ ]: AC

Grommet (G)

(Lead wire length)


Approx. 300
L1
14 L2

31.5
20.5

85.2[87.4]
86[88.2]

107.4[111.8]
R
R
B B B B B
(DIN: 65.1)

(DIN: 64.3)
122[126.4]

19 19
63.8

19
63

60
P
P

31.5
22
A A A A A

R
R
(DIN: 15.1)

1/4 (P, R port)


13.8

4-ø4.5
(Pitch)
29 P = 20 (For mounting)

Manual override

(Station 1) (Station n)
(Light/surge voltage suppressor)

-+ -+ -+
73[80]
57.6

A A
10.5

41
30.5

B B

6.5 1/8 (A, B port)


(Pitch)
25 P = 20

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
106.5
99
73[80] 87.7
M8 x 1 77.5
0.8
0.8

57.6 60
0.8

0.8
0.8

0.8
95.1[97.3]

105.1
104.2
85.3[87.5]
127.2[131.6]

94.2
107.6[112]

86.8
141.8[146.2]

122.2[126.6]

145.4

147.2

125.4

110.6
161.8

125.2
160

140

84.1[91.1]
Approx. 300
(Lead wire length)
(Lead wire length)

MAX.10

Pg7 Applicable cable O.D.


Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 78 98 118 138 158 178 198 218 238 258 278 298 318 338 358 378 398 418 438
L2 50 70 90 110 130 150 170 190 210 230 250 270 290 310 330 350 370 390 410

554
Manifold specifications 10-SYJ7000
Type 42: Side ported / 10-SS5YJ7-42- Stations - C6,N7
C8,N9 ∗ [ ]: AC

Grommet (G)

(Lead wire length)


Approx. 300

Air cylinder
L1
Manual override
14 L2
4-ø4.5
(For mounting) 32.5
19

Rotary actuator
85.9[88.1]

85.1[87.3]
107.4[111.8]
(DIN: 64.2)
R
B B B B B

R
(DIN: 65)
122[126.4]

18 18.5
62.9
63.7

59.9
21.9 19
P
P

31.4
A A A A A

R
R
(DIN: 15.2)

(4.9)
13.9

Air gripper
1/4 (P, R port)
(Pitch)
29 P = 19

Directional control
(Station 1) (Station n)
(Light/surge voltage suppressor)

valve
-+ -+ -+
74[81]
58.6

A A
42
29.5
8.5

B B

Flow control
equipment
8 (Pitch)
25 P = 19 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"

control equipment
Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
107.5
74[81] 100 M8 x 1
88.7

Fittings & Tubing


0.8
0.8

78.5
58.6
0.8

61
0.8

0.8
0.8
95[97.2]

85.2[87.4]

104.1

105
127.2[131.6]

94.1
107.6[112]
141.8[146.2]

122.2[126.6]

86.7
145.4

147.2

125.4

110.6
161.8

125.2
160

140

Air preparation
equipment

85.1[92.1]
Approx. 300
Pressure switch

(Lead wire length)


Pg7
(Lead wire length)

Applicable cable O.D.


MAX.10
Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.


Clean gas filter

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 77 96 115 134 153 172 191 210 229 248 267 286 305 324 343 362 381 400 419
L2 49 68 87 106 125 144 163 182 201 220 239 258 277 296 315 334 353 372 391

555
Manifold specifications 10-SYJ7000

Flat ribbon cable manifold ∗ [ ]: AC

10-SS5YJ7-21P- Stations (-00 )

(Lead wire length)


Approx. 300
L1
L2 10

- +
4-ø4.5
(For mounting)
- + - +
16.5
1/8 (A, B port)

1.5
15.3

11.5
141.8[146.2]

127.2[131.6]
17 21.5

21 19.5
R
R

30
A

21 21
61.5
62.3

93.6[95.8]
94.4[96.6]

60
P
P

93.8
B

R
R

16
- + - + - + - + - +

Manual override (Non-locking) (Pitch) Triangle mark 1/4 (P, R port)


P = 20.5 23.5

(Station n) (Station 1)
(Light/surge voltage suppressor)
58.5[65.5]

32.3
26.5

28.5
8.8

Applicable connector: 26 pins MIL type


(Conforming to MIL-C-83503)

With built-in One-touch fitting

One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"

(4.9) 63

Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations


L1 88 108.5 129 149.5 170 190.5 211 231.5 252 272.5
L2 68 88.5 109 129.5 150 170.5 191 211.5 232 252.5

556
Series 10-SYJ5000/7000
Made to order specifications
DIN terminal connector conforming to EN-175301-803C
(former DIN 43650C) standard

DIN terminal type conforming to DIN 43650C (DIN pitch 8mm) standard

Air cylinder
How to Order Valves
Light/surge voltage suppressor
Type of actuation
Nil Without light/surge voltage suppressor
1 2 position single solenoid
S With surge voltage suppresser
2 2 position double solenoid
Z With light/surge voltage suppresser Bracket
3 3 position closed center

Rotary actuator
∗ "YOZ" is not available. Nil Without bracket
4 3 position exhaust center ∗ For AC voltage valves, there is no "S" F With bracket
5 3 position pressure center option. It is already built-in to the
rectifier circuit. Note) Do not remove the factory
installed bracket from
models with the bracket
Rated voltage A, B port size option. Removal of the
DC specifications AC specifications (50/60Hz) M5 M5 x 0.8 bracket will cause air
5 24 VDC 1 100 VAC 01 1/8 (10- SYJ7000 only) leakage.
6 2

Air gripper
12 VDC 200 VAC C4 One-touch fitting for ø4
3 110 VAC [115 VAC] C6 One-touch fitting for ø6
4 220 VAC [230 VAC] N3 One-touch fitting for ø5/32"
N7 One-touch fitting for ø1/4

Directional control
Body ported 10 SYJ 5 1 23 5 Y M5

valve
Base mounted 10 SYJ 5 2 43 5 Y
Series Electrical entry Thread type

Flow control
equipment
5 10-SYJ5000 Nil Rc
Y: With connector F G
7 10-SYJ7000
N NPT
T NPTF

Port size
Nil Without sub-plate

control equipment
Filter, Pressure
10-SYJ5000
1 1/8
YO: Without connector 10-SYJ7000
2 1/4 10-SYJ7000

Manual override
Nil Non-locking push type
D Push-turn locking slotted type

Fittings & Tubing


E Push-turn locking lever type

How to Order Pilot Valve Assembly

10 V115 5 Y DIN connector part no.


Without light SY100-82-1
Rated voltage With light
Air preparation

Rated voltage Voltage symbol Part no.


equipment

DC specifications 24 VDC 24VN SY100-82-3-05


5 24 VDC 12 VDC 12VN SY100-82-3-06
Light/surge voltage suppressor
6 12 VDC 100 VAC 100VN SY100-82-3-01
Nil Without light/surge voltage suppressor
AC specifications (50 60 Hz) 200 VAC 200VN SY100-82-3-02
S With surge voltage suppresser
1 100 VAC 110 VAC [115 VAC] 110VN SY100-82-3-03
Z With light/surge voltage suppresser
2 200 VAC 220 VAC [230 VAC] 220VN SY100-82-3-04
Pressure switch

∗ "YOZ" is not available.


3 110 VAC [115 VAC] ∗ For AC voltage valves, there is
4 220 VAC [230 VAC] no "S" option. It is already built-in Caution
to the rectifier circuit. 1. Use caution in wiring because it won't meet the IP65 (enclosure) standard if you
use the other cord than prescribed cabtire cable of size (ø3.5 to ø7).
Also be sure to tighten the ground nut and set screw within the specified range of
torque.
Electrical entry For how to use DIN terminal (wiring procedures, procedures for changing electrical
entries, precautions, applicable cable, circuit diagram), refer to page 560.
Y With connector
Clean gas filter

DIN terminal 2. D type DIN connector with 9.4 mm pitch between terminals is not interchangeable.
YO Without connector 3. DIN connector except D type has the "N" indication in the end of voltage symbol. In
case of DIN connector without light, "N" is not indicated. Please refer to the name
plate to distinguish.
4. Dimensions are completely the same as D type connector.
5. When exchanging the pilot valve assembly only, "10-V115-첸D" is interchangeable
with "10-V115-첸Y". Do not replace 10-V114 (G, H, L, M, W) to 10-V115-첸D/첸Y
(DIN terminal), and vice versa.

557
Series 10-SYJ3000/5000/7000
Specific Product Precautions 1
Be sure to read before handling.

Manual override operation Solenoid valve for 200/220 VAC specifications

Warning Warning
When the manual override is operated, connected equipment will Solenoid valves with grommet and L/M type plug connector AC
be actuated. Confirm safety before operating. specificatinos have a built-in rectifier circuit in the pilot section to
operate the DC coil.
왎Non-locking push type (Standard) With 200/220 VAC specification pilot valves, this built-in rectifier
Press in the direction of the arrow. generates heat when energized. The surface may become hot
depending on the energized condition. Therefore, do not touch
the solenoid valves.

Series 10-SYJ3000, 5000, 7000


왎Push-turn locking slotted [Type D] Mixed installation of 3 port and 5 port valves
While pressing, turn in the direction of the arrow.
on the same manifold.
If it is not turned, it can be operated in the same way as the
non-locking type.
Locked position Caution
Series 10-SYJ3000/5000/7000 and Series 10-SYJ300/500/700
can be mounted on the same manifold. How to mount on the
PUSH

LOCK

same manifold is shown on the following pages.


10-SYJ3000, 10-SYJ300 ········· Page 507
10-SYJ5000, 10-SYJ500 ········· Page 529
Caution 10-SYJ7000, 10-SYJ700 ········· Page 550
When handling the locking type D with a screwdriver, turn it If 4 or 5 port valve is used as a 3 port valve
gently using a watchmaker's screwdriver. Series 10-SY 3000/5000/7000 may be used as a N.C. or N.O. 3
[Torque: 0.1 N·m or less] port valve by plugging one of the A, B ports. Be sure not to plug
the exhaust ports (R). Can be used when a double solenoide, 3
왎Push-turn locking lever [Type E] port valve is required.
While pressing, turn in the direction of the arrow.
If it is turned, it can be operated in the same way as the non- Plug position B port A port
Type of actuation N.C. N.O.
locking type.
Number of solenoids

(A) (B) Plug (A) (B)


4 2 Plug 4 2
Single

Locked position
5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
LOCK
PUSH

(A) (B) Plug (A) (B)


4 2 Plug 4 2
Double

5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)

(JIS Symbols above: Series 10-SYJ5000)


Caution
When locking the manual override on the push-turn locking
types (D, E), be sure to push it down before turning.
Turning without first pushing it down can cause damage to the
manual override and trouble such as air leakage, etc.

558
Series 10-SYJ3000/5000/7000
Specific Product Precautions 2
Be sure to read before handling.

Air cylinder
How to use plug connector Plug connector lead wire length

Caution Caution

Rotary actuator
1. Attaching and detaching connectors Standard length is 300 mm, but the following lengths are also
앬 To attach a connector, hold the lever and connector unit available.
between your fingers and insert straight onto the pins of the
solenoid valve so that the lever's pawl is pushed into the How to Order Connector Assembly
groove and locks.
For DC: SY100 30 4A
앬 To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the

Air gripper
For 100 VAC: SY100 30 1A
connector straight out.
Cover
Groove For 200 VAC: SY100 30 2A
Pin
Cover
Groove For other voltages of AC: SY100 30 3A

Directional control
Lever
Pin
DC polarity display
Without lead wire: SY100 30 A Lead wire

valve
-+

Socket (with connector and 2 of sockets only) length


Connector Lead wire Nil 300mm
How to Order
6 600mm
Hook Specify the connector assembly part
10 1000mm
number together with the part number for 15 1500mm
2. Crimping of lead wires and sockets the plug connector's solenoid valve without 20 2000mm

Flow control
equipment
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the connector. 25 2500mm
ends of the core wires evenly into the sockets, and then crimp <Example> Lead wire length 2000 mm 30 3000mm
50 5000mm
with a crimping tool. (For DC) For AC
When this is done, take care that the coverings of the lead 10-SYJ3123-5LO-M3 10-SYJ3123-1LO-M3
wires do not enter the core wire crimping area. SY100-30-4A-20 SY100-30-1A-20

control equipment
Filter, Pressure
Use an exclusive crimping tool for crimping.
(For special crimping tools, please contact SMC.)
Core wire crimping area Crimping area
Socket Core wire
Lead wire 0.2 to 0.33mm2
Max. cover diameter: ø1.7 mm

Fittings & Tubing


Hook Insulation

3. Attaching and detaching sockets with lead wires


앬 Attaching
Insert the sockets into the square holes of the connector
( + and - indication), and continue to push the sockets all
the way in until they lock by hooking into the seats in the
Air preparation
equipment

connector. (When they are pushed in, their hooks open and
they are locked automatically.) Then confirm that they are
locked by pulling lightly on the lead wires.
앬 Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket's hook with a stick having a thin tip
Pressure switch

(approx. 1 mm).
If the socket will be used again, first spread the hook
outward.

Socket Connector
Clean gas filter

Lead wire
Hook

559
Series 10-SYJ3000/5000/7000
Specific Product Precautions 3
Be sure to read before handling.

Surge voltage suppressor

Caution
(For DC)
Grommet, L/M plug connector type DIN terminal
왎Standard type (with polarity) With surge voltage suppresser (DS)
With surge voltage suppresser (첸S)

Varistor
Diode to prevent reverse current

Coil
Red (+)

Black (–) Coil


With light/surge voltage suppresser (DZ)
With light/surge voltage suppresser (첸Z)
Diode to prevent reverse current

Varistor
Red (+)

Coil
Coil

Black (–)
DIN terminal has no polarity.
왎Non-polar type
With surge voltage suppresser (첸R)
(–) (+) M8 connector type
Coil

Varistor (Ground) 왎Standard type (with polarity)


(+) (–) With surge voltage suppresser (첸S)
4
With light/surge voltage suppresser (첸U) Diode to prevent reverse current
(–) (+)
1 (+)
Coil

Coil
Varistor
1 3
(+) (–)
3 (–)
· Connect the standard type in accordance with the +, – polarity
indication. Solenoid valve side
(The non-polar type can be used with the connections made Pin wiring diagram With light/surge voltage suppresser(첸Z)
either way.) Diode to prevent reverse current

· Since voltage specifications other than standard 24 and 12 VDC 1 (+)


do not have diodes for polarity protection, be careful not to

Coil
make errors in the polarity.
· Be careful about the allowable voltage fluctuation since the 3 (–)
valves with a diode to prevent reverse current has about a 1V
voltage drop. (Refer to the solenoid specifications of each valve 왎Non-polar type
for details.) With surge voltage suppresser (첸R)
(Ground)
· When wiring is done at the factory, positive (+) is red and 1 (–) (+)
negative (–) is black. 4
Coil

왎With power saving circuit Electric circuit (with power saving circuit)
Varistor
3 (+) (–)
Power consumption is de- Red (+)
Diode
Timer circuit

creased by 1/4 by reducing 1 3


Coil

LED
the wattage required to hold With light/surge voltage suppresser (첸U)
the valve in an energized 1 (–) (+)
1 2
state. (Effective energizing Black (–) Solenoid valve side
Coil

1: Starting current 2: Holding current Varistor


time is over 62 ms at 24 VDC.) Pin wiring diagram
3 (+) (–)
Working principle
(Energy saving type's electrical power
With the above circuit, the current 3 · In the case of standard type, connect + to 1 and – to 3 according
waveform : SYJ5 첸첸0T)
consumption when holding is re- 7 to the polarity.
duced to save energy. Please refer 24V
Applied voltage · For DC voltages other than standard 12/24 VDC, use caution not
to the electric wave data to the right. to mistake the polarity because a diode to prevent reverse
0V
· When a power saving circuit is in- current is not provided.
stalled, a diode to prevent reverse 0.4W Standard · Be careful about the allowable voltage fluctuation since the
With power
current is not provided. Therefore, 0.1W
saving circuit valves with a diode to prevent reverse current has about a 1V
use caution not to connect in re- 0W voltage drop. (Refer to the solenoid specifications of each valve
62ms
verse. for details.)
· Be careful about the allowable voltage fluctuation since voltage
drop of about 0.5V occurs due to a transistor. (Refer to the sole-
noid specifications of each valve for details.)

560
Series 10-SYJ3000/5000/7000
Specific Product Precautions 4
Be sure to read before handling.

Air cylinder
Surge voltage suppressor How to use DIN Terminal
<For AC> Ground nut
(There is no "S" type because the generation of surge voltage is Tightening torque

Rotary actuator
prevented by a rectifier.) 1.65 to 2.5 N·m
Holding screw
Tightening torque
Grommet, L/M plug connector 0.4 N·m
Washer
With indicator light (첸Z) Grommet
(~)
(Rubber) Housing
Varistor

Coil
(Rating symbol)
Refer to table of
(~) DIN connector part no. (Light mounting
location )

Air gripper
Terminal screw Terminal block
DIN terminal (3 locations) Notch
With indicator light (DZ) Tightening torque
(~)
0.2 to 2.5 N·m
Varistor

Coil

Directional control
(~) DIN connector part no.
NL : Neon ball

valve
Note) Surge voltage suppressor of varistor has residual voltage
corresponding to the protective element and rated voltage. Caution
Therefore, protect the controller side from the surge.
The residual voltage of the diode is approximately 1 V. Without light SY100-61-1
With light

Flow control
Rated voltage Voltage symbol Part no.

equipment
How to use DIN Terminal 24 VDC 24V SY100-61-3-05
12 VDC 12V SY100-61-3-06

Caution 100 VAC


200 VAC
100V
200V
SY100-61-2-01
SY100-61-2-02
Connection 110 VAC 110V SY100-61-2-03
1. Loosen the holding screw and pull the connector out of the 220 VAC 220V SY100-61-2-04

control equipment
Filter, Pressure
solenoid valve terminal block.
2. After removing the holding screw, insert a flat head Circuit diagram with light
screwdriver, etc. into the notch on the bottom of the terminal AC circuit DC circuit
block and pry it open, separating the terminal block and the
housing.
3. Loosen the terminal screws (slotted screws) on the terminal
block, insert the cores of the lead wires into the terminals

Fittings & Tubing


according to the connection method, and fasten them securely
with the terminal screws.
4. Secure the cord by fastening the ground nut. NL: Neon light LED: Light emitting diode
R: Resistor R: Resistor
Caution Note) Refer to page 557 for DIN connector (Y) conforming to EN-175301-803C (former DIN
When making connections, note that using other than the 43650C).
supported size (ø3.5 to ø7) cabtire cable will not satisfy IP65
(enclosure) standards.
Air preparation
equipment

Also, be sure to tighten the ground nut and holding screw within
their specified torque ranges.

Caution
Changing the entry direction
After separating the terminal block and housing, the cord entry
Pressure switch

can be changed by attaching the housing in the desired direction


(4 directions at 90° intervals).
∗ When equipped with an indicator light, be careful not to damage
the light with the cord's lead wires.
Precautions
Plug in and pull out the connector vertically without tilting to one
Clean gas filter

side.
Compatible cable
Cord O.D.: ø3.5 to ø7
(Reference) 0.5 mm2, 2 core or 3 core, equivalent to JIS C 3306

561
Series 10-SYJ3000/5000/7000
Specific Product Precautions 5
Be sure to read before handling.

Connector assembly with cover M8 connector

Caution Caution
Connector assembly with dustproof protective cover 1. M8 connector types have an IP65 (enclosure) rating, offering
· Effective to prevent short circuit failure due to the entry of foreign protection from dust and water. However please note that
matter into the connector these products are not intended for use in water.
· Chloroprene rubber for electrical use, which provides outstand- Select a SMC connector cable (V100-49-1-첸) or a FA sensor
ing weather resistance and electrical insulation, is used for the type connector, with M8 threaded 3 pin specifications
cover material. However, do not allow contact with cutting oil, conforming to Nippon Electric Control Equipment Association
etc. Standard, NECA4202 (IEC60947-5-2). Make sure the
· Simple and unencumbered appearance by adopting round- connector O.D. is 10.5 mm or less when used with the Series
shaped cord. 10-SY3000 manifold. If more than 10.5mm, it cannot be
mounted due to the size.
How to Order 2. Do not use a tool to mount the connector, as this may cause
damage. Only tighten by hand. (0.4 to 0.6N)
SY100-68-A 3. Do not apply excessive power greater than 30N to the connec-
Lead wire length tor cable, otherwise IP65 cannot be satisfied.
Nil 300mm
6 600mm
Caution
10 1000mm Failure to meet IP65 performance may result if using alternative
15 1500mm connectors than shown above, or when insufficiently tightened.
20 2000mm
25 2500mm · Connector cable mounting
30 3000mm
50 5000mm
Triangle mark
Arrow mark
Connector assembly with cover: Dimensions
(40) Gray

(10)
(ø4.1)
(6.9)

Red Black (8)


(8)

Note) Connector cable should be mounted in the correct direc-


tion. Make sure that the arrow symbol on the connector is
(14.5) L facing the triangle symbol on the valve when using SMC
connector cable (V100-49-1-첸).
Be careful not to squeeze it in the wrong direction, as
problems such as pin damage may occur.

MConnector cable
· Connector cable for M8 can be ordered as follows:

How to Order How to Order


Enter the part number for a plug connector solenoid valve without 1. To order solenoid valve and connector cable at the same time.
connector together with the part number for a connector (Connector cable will be included in the shipment of the solenoid
assembly with cover. valve.)
<Example 1> Lead wire length 2000 mm 3
10-SYJ3123-5LOZ-M3 10 SYJ 57 3
SY100-68-A-20 Electrical entry
<Example 2> Lead wire length 300mm (Standard) W1: Cable length 300 mm
10-SYJ3123-5LPZ-M3 W2: Cable length 500 mm
W3: Cable length 1000 mm
Symbol for connector assembly with cover W4: Cable length 2000 mm
W7: Cable length 5000 mm
∗ In this case, the part number for the connector assembly with
cover is not required. (Example 1) Cable length 300 mm
10-SYJ3123-5W1ZE-M3
Symbol for electrical entry

562
Series 10-SYJ3000/5000/7000
Specific Product Precautions 6
Be sure to read before handling.

Air cylinder
M8 connector Flat ribbon cable manifold
2. To order connector cable only Internal wiring of manifold

Rotary actuator
(Ground) Connector dimensions
4 Brown: 1 Blue: 3 Station 12 Station 4 Station 3 Station 2 Station 1
Coil
ø9

3 1
Black: 4 Side A Side B Side A Side B Side A Side B Side A Side B Side A Side BTriangle mark
33.9 Coil Coil Coil Coil Coil Coil Coil Coil Coil Coil Indicated position

L 35 10 25 23
7 5 3 1 Note)
Connector

Air gripper
26 24
8 6 4 2
Cable length (L) Part no.
300mm V100-49-1-1

) ( ) Side A Coil
) ( ) Side B Coil

( ) ( ) Side A Coil
) ( ) Side B Coil

) ( ) Side A Coil
) ( ) Side B Coil

) ( ) Side A Coil
) ( ) Side B Coil

) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Common
) ( ) Common
500mm V100-49-1-2
1000mm V100-49-1-3
2000mm V100-49-1-4 + +

Directional control
+ + + + + + + + + +
5000mm V100-49-1-7
-
-
{((

-
-

-
-

-
-
-
-
-
-

{ ((
{(

{ ((

{ ((
{ ((
Connected

valve
on the
22 33.9 board Station 12 Station 4 Station 3 Station 2 Station 1
1
Triangle mark 2
(Max. 12 stations)
3
24
25
Reference figure 26
Note)
14

Flow control
equipment
Terminal no. is not indicated on the connector. The terminal no.
indicated in the connection schematic of connector, as shown in
the reference, means a correlation of 1, 2, 3···26 from the triangle
mark side on the flat ribbon cable of connector.
Flat ribbon cable manifold
· For more than 10 stations, both poles of the common should be

control equipment
Caution wired.

Filter, Pressure
· For single solenoid, connect to the solenoid B side.
Type 21P Type 32P · The maximum number of stations that can be accommodated is
12. Please contact SMC for more stations.
· Only non-polar valves are available for the DC flat ribbon cable
manifold, therefore negative COM or positive COM wiring of the
manifold is possible. The valve dose not switch with negative

Fittings & Tubing


COM if a Z type is used. Be sure to use positive COM.

Bracket
• In the manifold valves, the wiring to the individual valves is
provided on a printed circuit board, and the connection to the
external wires is consolidated through the use of a flat cable.
Caution
For 10-SYJ3000 (Single) or 10-SYJ7000 with bracket, do not use
•A single MIL flat cable connects the entire manifold to your
Air preparation

it without bracket.
equipment

power source. This greatly reduces installation time and


provides clean appearance.

Replacement of solenoid valve

Caution
Pressure switch

Mount it so that there is no slippage or deformation in gaskets,


and tighten with the tightening torque as shown below.

Model Thread size Tightening torque


10-SYJ3000 M1.7 0.12N·m
10-SYJ5000 M2.5 0.45N·m
Clean gas filter

10-SYJ7000 M3 0.8N·m

563
Series 10-SYJ3000/5000/7000
Specific Product Precautions 7
Be sure to read before handling.

Replacement of pilot valve

Caution
Pilot valves in this series are improved to provide excellent
energy saving results. However, following this improvement,
these new valves are no longer compatible with the conventional
pilot valve used at the interface. Please consult with SMC when
you need to exchange these pilot valves, in the case of manual
override (marked in orange) of the adapter plate.

New type
Manual override
(Blue)
-+

B
A

Interface

Pilot valve
(10-V111) Adapter plate

Conventional type
Manual override
(Orange)
-+

B
A

Interface

Pilot valve
(10-SY114) Adapter plate

564
Series 10-SYJ3000/5000/7000 Rubber seal
4/5 port solenoid valve

Variations
Option
Sonic conductance Type of Manual
Series Voltage Electrical entry
C[dm3/(s·bar)] actuation Light/Surge override
voltage suppresser

10-SYJ3000 For DC For DC


Effective area
0.9mm2
4/2→5/3 왎 24 VDC Grommet 왎 With surge
(A/B→EA/EB) 12 VDC voltage suppresser
6 VDC
P.494 5 VDC –+
3 VDC
Body ported

10-SYJ5000
0.47 왎 With light/surge
L plug connector voltage suppressor
4/2→5/3
(A/B→EA/EB) }
P.515

+

10-SYJ7000 For AC
2.4 2 position M plug connector
4/2→5/3
(A/B→EA/EB) } · Single
· Double
왎AC 100V / Hz
50
60

AC 110V 50
/ Hz60

AC 200V 50
/ Hz60 +–

P.537 AC 220V 50
/ Hz60
왎 Non-locking
push type
10-SYJ3000
3 position
0.46
· Closed center
4/2→5/3
(A/B→EA/EB) } · Exhaust center
· Pressure center
왎 Push-turn
Base mounted type

P.494 For AC Note) locking slotted


DIN terminal type
왎 With light/surge
10-SYJ5000
voltage suppresser
0.83
왎 Push-turn
4/2→5/3
(A/B→EA/EB) } locking
lever type
(10-SYJ5000/7000
only)
P.515

10-SYJ7000 M8 connector

2.9
4/2→5/3
(A/B→EA/EB) }
P.537
Note) All standard AC voltage models have built-in surge voltage suppresser.

492
4/5 port solenoid valve Series 10-SYJ3000/5000/7000

Manifold variations
A, B port size Manifold option

One-touch fitting

Air cylinder
A, B port Flat ribbon cable manifold
Valve series Individual Individual
location M3 M5 1/8 Applicable tubing O.D. SUP spacer EXH spacer
assembly assembly
ø4 ø6 ø8 N3 N7 N9

10-SYJ3000 앬 — — — — — — — — — — 앬
Body ported

Rotary actuator
10-SYJ5000 Top — 앬 — 앬 앬 — 앬 앬 — 앬 앬 앬

10-SYJ7000 — — 앬 — 앬 앬 — 앬 앬 — 앬 앬

Side 앬 앬 — 앬 — — 앬 — — 앬

Air gripper
10-SYJ3000 — —
Bottom — — — — — — — — — —
Base mounted

Side — 앬 — 앬 앬 — 앬 앬 — 앬

Directional control
10-SYJ5000 앬 앬

valve
Bottom — — — — — — — — —

Side — — 앬 — 앬 앬 — 앬 앬 —
10-SYJ7000 앬 앬
Bottom — — 앬 — — — — — —

Flow control

equipment
Body ported Type 21P
A, B port

P port

control equipment
Filter, Pressure
Individual SUP
R port spacer assembly
Base mounted
P port

P
Type 32P

Fittings & Tubing


R port
A, B port

R port
A, B port
P port
Air preparation
equipment

Mixed mounting of 3 port valves and 4, 5 port valves

Individual EXH 4/5 port valve


3 port valve
R port spacer assembly
A, B port R2
P port
Pressure switch

R1

R port
· For detailed specifications about 10-
A, B port SYJ3000, refer to page 507. For 10-
P port SYJ5000, refer to page 529, and for
10-SYJ7000, refer to page 550.
Clean gas filter

493
Series 10-SYJ3000 Rubber seal
4/5 port solenoid valve

Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure range (MPa) 2 position double 0.1 to 0.7
3 position 0.2 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (with no freezing. Refer to page 714.)
Response time ms 2 position single, double 15 or less
(0.5MPa) Note 1) 3 position 30 or less
2 position single, double 10
Max. operating frequency (Hz)
3 position 3
Body ported Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
2 Note 2)
Shock/Vibration resistance m/s 150/30
Enclosure Dustproof (∗ M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature : 20°C, at rated voltage and
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000Hz. Test
was performed to axis and right angle directions of the main valve when pilot signal is ON and
Base mounted OFF. (Value in the initial state)

Solenoid specifications
JIS Symbol
5 port 4 port (For manifold
use only) Electrical entry Grommet (G)/(H), L plug connector (L),
2 position single 2 position single M plug connector (M), M8 connector (W)
(B) (A) (B)(A)
2 4 2 4 DC 24, 12, 6, 5, 3
Coil rated voltage V
AC50/60Hz 100, 110, 200, 220
3 1 5
(R) (P) (R)
1 3 Allowable voltage fluctuation ±10% of rated voltage ∗
(P) (R)
2 position double 2 position double Standard 0.35 (With indicator light: 0.4)
(B) (A) (B) (A) Power consumption (W) DC
2 4 2 4 With power saving circuit 0.1 (With indicator light only)
100 VAC 0.78 (With indicator light: 0.81)
3 1 5 110 VAC 0.86 (With indicator light: 0.89)
(R) (P) (R) 1 3
(P) (R)
Apparent power (VA) ∗ [115 VAC] [0.94(With indicator light: 0.97)]
3 position closed center 3 position closed center AC
(B) (A) (B) (A) 200 VAC 1.18 (With indicator light: 1.22)
2 4 2 4
220 VAC 1.30 (With indicator light: 1.34)
3 1 5 [230 VAC] [1.42 (With indicator light: 1.46)]
(R) (P) (R) 1 3
(P) (R) Surge voltage suppressor Diode (Non-polar type: Varistor)
3 position exhaust center 3 position exhaust center Indicator light LED
(B)(A) (B) (A)
2 4 2 4
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is -15% to +5% of rated voltage.
3 1 5
(R) (P) (R) 1 3 ∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please
(P) (R) observe the following range because they have voltage drop due to internal circuit.
3 position pressure center 3 position pressure center
(B) (A) (B) (A) S and Z types 24 VDC: -7% to +10% 12 VDC: -4% to +10%
2 4 2 4 T type 24 VDC: -8% to +10% 12 VDC: -6% to +10%

3 1 5
Bracket mounting
(R) (P)(R) 1 3
(P) (R) (1) Insert the lower hook of the mounting (2) Press the valve and mounting bracket
bracket into the groove on the bottom of together until the upper hook of the bracket
the valve as shown. snaps into place in the groove on top of the
Made to valve.
Order Made to order specifications
(Refer to page 557 for details.)

494
4/5 port solenoid valve Series 10-SYJ3000
Flow characteristics / Weight
Port size Weight (g) Note 3, 4) Flow characteristics Note 2)
Effective
Valve model Type of actuation 1, 5, 3 4, 2 L/M plug M8 area mm 2 1→4/2(P→A/B) 4/2→5/3(A/B→EA/EB)
Grommet

Air cylinder
(P, EA, EB) (A, B) connector Connector C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv
10-SYJ3143 2 Single 62(36) 63(37) 67(41) —
0.46 0.36 0.12 0.46 0.35 0.12
5 port base 10-SYJ3243 position Double 79(53) 81(55) 89(63)
mounted 10-SYJ3343 Closed center M5 x 0.8 M5 x 0.8 — 0.47 0.33 0.12 0.47 0.31 0.12
(With sub-plate) 10-SYJ3443 3 Exhaust center 82(56) 84(58) 92(66) — 0.36 0.39 0.10 0.59[0.40] 0.43[0.33] 0.16[0.11]
position
10-SYJ3543 Pressure center — 0.58[0.32] 0.42[0.33] 0.16[0.080] 0.46 0.32 0.11
10-SYJ3123 2 Single 36 37 41

Rotary actuator
10-SYJ3223 position Double 53 55 63
5 port
10-SYJ3323 Closed center M3 x 0.5 M3 x 0.5 0.9
body ported 3
10-SYJ3423
position
Exhaust center 56 58 66
10-SYJ3523 Pressure center
10-SYJ3133 2 Single 36 37 41 —
4 port base 10-SYJ3233 position Double 53 55 63
mounted
10-SYJ3333 Closed center 1/8 M5 x 0.8 —
(For manifold 3
base only)Note 1) 10-SYJ3433 position Exhaust center 56 58 66 —

Air gripper
10-SYJ3533 Pressure center —
Note 1) Dedicated for manifold base, refer to page 11 for details.
Note 2) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 3) ( ): Without sub-plate
Note 4) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the
weight of the double solenoid and 3 position types.

Directional control
valve
Flow control
equipment
control equipment
Filter, Pressure
Fittings & Tubing
Air preparation
equipment
Pressure switch
Clean gas filter

495
4/5 port solenoid valve Series SYJ3000

How to Order
Light/surge voltage suppressor Bracket
Type of actuation Nil Without light/surge voltage suppressor Nil: Without bracket F: With bracket
1 2 position single solenoid S With surge voltage suppressor
2 2 position double solenoid Z With light/surge voltage suppressor
3 3 position closed center R With surge voltage suppressor (Non-polar type)
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
5 3 position pressure center
∗ For AC voltage valves, there is no "S" option. It is -+

already built-in to the rectifier circuit.


∗ For "R" and "U", DC voltage is only available. Single Double
∗ Power saving circuit is only available in the "Z" type. (Bracket cannot be retrofitted.)

5 port Rated voltage Note) The double solenoid mounting bracket is supplied
unattached.
DC AC (50/60Hz) To order the double solenoid bracket for use with a
5 24 VDC 1 100 VAC single solenoid valve, order the single solenoid
valve without a bracket and double solenoid
6 12 VDC 2 200 VAC
bracket separately by specifying the part number
V 6 VDC 3 110 VAC [115 VAC] of the bracket VJ3000-13-1besides the part
S 5 VDC 4 220 VAC [230 VAC] number of the solenoid valve.
∗ For type "W첸", DC voltage [Example] 10-SYJ3123-5M-M3
R 3 VDC
(Type 20 manifold) is only available. VJ3000-13-1

Body ported 10 SYJ3 1 23 5 M M3


Base mounted
(4 port) 10 SYJ3 2 33 5 M (Manifold use only)
Base mounted
(5 port) 10 SYJ3 2 43 5 M
4 port Clean series Coil specifications Manual override Port size
Nil Standard
Nil: Non-locking push type Nil: Without sub-plate
With power saving circuit
T
<24, 12 VDC only>
∗ Power saving circuit is
not available in the case
For manifold of "W첸" type.
type 31, S31, 32, S32
5 port
(With gasket and screws)
D: Push-turn locking
slotted type M5: With M5 port sub-plate

For sub-plate, manifold


type 41, S41, 46, S46

Electrical entry
24, 12, 6, 5, 3 VDC 24, 12 VDC
100, 110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector M8 connector E: Push-turn locking lever type
G: Lead wire L: With lead M: With lead wire MN: Without WO: Without connector
length wire (length (length 300 mm) lead wire cable
300 mm 300 mm)

+– +–

–+
–+

H: Lead wire LN: Without LO: Without MO: Without W첸: With connector
length lead wire connector connector cable Note 1)
600 mm

–+
–+

Note) When placing an order for body ported


solenoid valve as a single unit, mounting
bolt for manifold and gasket are not
∗ "LN", "MN" types: with 2 sockets. attached. Order them separately, if
∗ For connector cable of M8 connector, refer to page 562. necessary.
Note 1) Be sure to enter a symbol of the cable length in 첸 with reference to P562. (Refer to catalog page 508 for details.)
496
4/5 port solenoid valve Series 10-SYJ3000

How to Order Pilot Valve Assembly How to Order Connector Assembly for L/M Plug Connector

Air cylinder
10 V111 5 G For DC : SY100-30-4A-
Clean series
Light/Surge voltage suppressor
For 100 VAC : SY100-30-1A-
Nil Without light/surge voltage suppressor
Coil specifications S With surge voltage suppresser For 200 VAC : SY100-30-2A-

Rotary actuator
Nil Standard Z With light/surge voltage suppresser
R
T
With power saving circuit
<24, 12 VDC only> U
With surge voltage suppressor (Non-polar type)
With light/surge voltage suppressor (Non-polar type)
For other voltages of AC : SY100-30-3A-
∗ Power saving circuit ∗ For AC voltage valves, there is Without lead wire
is not available in
the case of "W첸"
no "S" option. It is already built-
in to the rectifier circuit.
(With connector and 2 of sockets only) : SY100-30-A
type. ∗ For "R" and "U", DC voltage is
only available. Lead wire length
∗ Power saving circuit is only available Nil 300mm

Air gripper
in the "Z" type. 6 600mm
10 1000mm
Rated voltage Electrical entry 15 1500mm
5 24 VDC G Grommet (Lead wire length 300 mm) 20 2000mm
6 12 VDC H Grommet (Lead wire length 600 mm) 25 2500mm
V 6 VDC L With lead wire 30 3000mm
S 5 VDC L plug 50 5000mm
LN connector Without lead wire

Directional control
R 3 VDC
1 100 VAC50/60Hz LO Without connector
2 200 VAC50/60Hz M With lead wire

valve
M plug
3
110 VAC50/60Hz
[115 VAC50/60Hz]
MN connector Without lead wire How to Order M8 Connector Cable
MO Without connector
220 VAC50/60Hz WO M8 Without connector cable
4
[230 VAC50/60Hz] W첸 Connector With connector cable Note 1) V100-49-1-
∗ For type "W첸", DC ∗ For connector cable of M8 connector,
voltage is only avail- refer to page 562.
Cable length

Flow control
equipment
able. Note 1) Be sure to enter a symbol of the
cable length in 첸 with reference 1 300mm
to page 562. 2 500mm
3 1000mm
4 2000mm
7 5000mm

control equipment
Filter, Pressure
Fittings & Tubing
Air preparation
equipment
Pressure switch
Clean gas filter

497
4/5 port solenoid valve Series 10-SYJ3000

2 position single ∗[ ]: AC

Grommet (G), (H): 10-SYJ3123-첸 GH 첸첸-M3 With bracket: 10-SYJ3123-첸 GH 첸첸-M3-F

G: Approx. 300
54.4[56.6] H: Approx. 600
(Lead wire length) 28.4
32.2 2-ø3.5 22 3.2
(For mounting)
13.2 7.1

16.4
10
- +
8.2
4

A B

11.5 19.3
7 Manual override
34.7[41.7]
M3 x 0.5 2-ø1.8
(A, B port) (For manifold mounting) (Light/surge voltage suppressor)

28[35]
-+
22.1

13.5

12.6

54.4[56.6]
15

2
R P R (Bracket) 15
11
10

22.1
7 7
15 M3 x 0.5
(P, R port)

L plug connector (L): M plug connector (M): M8 Connector (WO):


10-SYJ3123-첸L첸첸-M3 (-F) 10-SYJ3123-첸M첸첸-M3 (-F) 10-SYJ3123-첸WO첸첸-M3 (-F)
(Lead wire length)
Approx. 300

28[35]

12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
64.3[66.5]

54.5[56.7]

63.4
56
49.5
(2)

(2)
(2)

13.5 13.5 13.5


15 15 15
22.1 22.1 22.1

∗ Refer to page 563 for dimensions with connector cable.

498
4/5 port solenoid valve Series 10-SYJ3000

2 position double ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ3223-첸 H 첸첸-M3 (-F)

Air cylinder
G: Approx. 300
78.8[83.2] H: Approx. 600
34.4 (Lead wire length)

7.1
1.8

Rotary actuator
4
8.2 A B

M3 x 0.5 7 Manual override


(A, B port)
2-ø1.8
(For manifold mounting)

Air gripper
Equivalent to 2-ø3.2 Bracket (Light/surge voltage suppressor)
(For mounting) (18.5)

28[35]
(18.5)
22.1

-+

13.5

12.6
15

Directional control
valve
(11.5)
10 0.5

R P R

14

Flow control
equipment
M3 x 0.5
(P, R port)

control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 connector (WO):
10-SYJ3223-첸L첸첸-M3 (-F) 10-SYJ3223-첸M첸첸-M3 (-F) 10-SYJ3223-첸WO첸첸-M3 (-F)
(Lead wire length)
Approx. 300

28[35]

Fittings & Tubing


12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
Air preparation
equipment

13.5 13.5 13.5


98.6[103]

79[83.4]

96.8
69

82

Pressure switch

15
22.1 15
15
22.1
22.1
Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

499
4/5 port solenoid valve Series 10-SYJ3000

3 position closed center / exhaust center / pressure center ∗ [ ]: AC

3
Grommet (G), (H): 10-SYJ3 45 23-첸GH첸첸-M3 (-F)

G: Approx. 300
91.7[96.1] H: Approx. 600
40.2[42.4] (Lead wire length)
29.3 18
1.8 5.3

4
8.2

A B

M3 x 0.5 7 Manual override


(A, B port) 2-ø1.8
(For manifold mounting)

Equivalent to 2-ø3.2 Bracket (Light/surge voltage suppressor)


(For mounting) (18.5)

28[35]
(18.5)
22.1

-+

13.5

12.6
15

(11.5)
10 0.5

R P R

14

M3 x 0.5
(P, R port)

L plug connector (L): M plug connector (M): M8 Connector (WO):


3 3 3
10-SYJ3 45 23-첸L첸첸-M3 (-F) 10-SYJ3 45 23-첸M첸첸-M3 (-F) 10-SYJ3 45 23-첸WO첸첸-M3 (-F)
(Lead wire length)
Approx. 300

28[35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
50.1[52.3]

40.3[42.5]

49.2
41.8
35.3

13.5 13.5 13.5


111.5[115.9]

91.9[96.3]

109.7
46.6

53.1

15
22.1 15
15
22.1
22.1

∗ Refer to page 563 for dimensions with connector cable.

500
4/5 port solenoid valve Series 10-SYJ3000

2 position single ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ3143-첸 H 첸첸-M5

Air cylinder
M5 x 0.8 10
(A, B port)

5
10

Rotary actuator
2-ø3.2 32.2
(For mounting)
22 4

2.5
Manual override
B A

11
A
B

Air gripper
G: Approx. 300 1
H: Approx. 600 54.4[56.6]
(Light/surge voltage suppressor) (Lead wire length)

Directional control
41.5[48.5]

-+

35.6

valve
28.5
26.1

R2 P R1
13

10 10 10 M5 x 0.8
17.5 (Mounting hole)
14
28

Flow control
equipment
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 Connector (WO):
10-SYJ3143-첸L첸첸-M5 10-SYJ3143-첸M첸첸-M5 10-SYJ3143-첸WO첸첸-M5
(Lead wire length)

Fittings & Tubing


Approx. 300

41.5[48.5]
26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
Air preparation
equipment
64.3[66.5]

54.5[56.7]

63.4
56
49.5
R2

R2

R2
10 10

10 10

10 10
28

28

28
P

P
14

14

14
R1

R1

R1

Pressure switch

5 5 5
28.5 28.5 28.5
35.6 35.6 35.6
Clean gas filter

∗ Refer to page 563 for dimensions


with connector cable.

501
4/5 port solenoid valve Series 10-SYJ3000

2 position double ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ3243-첸 H 첸첸-M5

M5 x 0.8 10
(A, B port)

5
10
2-ø3.2
(For mounting) 22

2.5
Manual override

11
G: Approx. 300 34.4
H: Approx. 600 78.8[83.2]
(Light/surge voltage suppressor) (Lead wire length)
41.5[48.5]

35.6
26.1
13

10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)
28

L plug connector (L): M plug connector (M): M8 connector (WO):


10-SYJ3243-첸L첸첸-M5 10-SYJ3243-첸M첸첸-M5 10-SYJ3243-첸WO첸첸-M5
(Lead wire length)
Approx. 300

41.5[48.5]
26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
98.6[103]

79[83.4]
10 10

10 10

10 10

96.8
28

28

69

28

82
14

14

14

5 5 5

∗ Refer to page 563 for dimensions


with connector cable.

502
4/5 port solenoid valve Series 10-SYJ3000

3 position closed center / Exhaust center / Pressure center ∗ [ ]: AC


3
Grommet (G), (H): 10- SYJ3 45 43-첸 GH 첸첸-M5

Air cylinder
M5 x 0.8
10 (A, B port)

5
10

Rotary actuator
2-ø3.2 32 15.3
(For mounting)
22 3

2.5
Manual override
B A

11

Air gripper
A
B
37.5[39.7]
G: Approx. 300
H: Approx. 600 91.7[96.1]
(Lead wire length)
(Light/surge voltage suppressor)

Directional control
41.5[48.5]

-+

valve
35.6
26.1

R2 P R1
13

10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)

Flow control
equipment
28

control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 Connector (WO):
3 3 3
10-SYJ3 45 43-첸L첸첸-M5 10-SYJ3 45 43-첸M첸첸-M5 10-SYJ3 45 43-첸WO첸첸-M5첸
(Lead wire length)
Approx. 300

41.5[48.5]

Fittings & Tubing


26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
Air preparation
equipment
55.8
49.3
111.5[115.9]
R2

R2

R2
91.9[96.3]
10 10

10 10

10 10
28

28

28

109.7
P

P
14

14

14
R1

R1

R1

5 5 5
37.6[39.8]
47.4[49.6]

32.6

Pressure switch
39.1
46.5

Clean gas filter

∗ Refer to page 563 for dimensions


with connector cable.

503
Series 10-SYJ3000 Manifold specifications

Manifold standard

Manifold specifications

Model Type 20 Type 31/S31 Type 32/S32 Type 41/S41 Type 46/S46

Manifold type Single base / B mount

Common SUP / Common EXH Common SUP /


P (SUP) / R (EXH) Individual EXH
Valve stations 2 to 20 stations
A, B port porting Location Valve Base
specifications Direction Top Side

P, R port M5 x 0.8 1/8 P: 1/8


Port size R: M5 x 0.8
A, B port M3 x 0.5 M5 X 0.8, C4 (One-touch fitting for ø4)

Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R) Effective
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C (mm2)
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
Body ported for
10-SS5YJ3-20 10-SYJ3첸23 M5 x 0.8 M3 x 0.5 — — — — — — 0.9
internal pilot
10-SS5YJ3-31-S31 10-SYJ3첸33 M5 x 0.8 M3 x 0.5 — — — — — — 0.9
10-SS5YJ3-32-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 —
10-SS5YJ3-32-C4 C4 0.25 0.18 0.059 0.30 0.27 0.075 —
10-SYJ3첸33 1/8
10-SS5YJ3-S32-M5 M5 x 0.8 0.25 0.26 0.060 0.29 0.15 0.062 —
10-SS5YJ3-S32-C4 C4 0.24 0.21 0.057 0.27 0.18 0.062 —
Base mounted for 10-SS5YJ3-41-M5 M5 x 0.8 0.32 0.25 0.081 0.33 0.19 0.079 —
internal pilot 10-SS5YJ3-41-C4 C4 0.32 0.28 0.079 0.35 0.24 0.084 —
10-SYJ3첸43 1/8
10-SS5YJ3-S41-M5 M5 x 0.8 0.33 0.29 0.082 0.34 0.17 0.081 —
10-SS5YJ3-S41-C4 C4 0.32 0.27 0.079 0.34 0.24 0.084 —
10-SS5YJ3-46-M5 M5 x 0.8 0.20 0.25 0.048 0.10 0.12 0.024 —
10-SS5YJ3-46-C4 1/8 C4 0.21 0.27 0.050 0.21 0.13 0.047 —
10-SYJ3첸43
10-SS5YJ3-S46-M5 M5 x 0.8 M5 x 0.8 0.20 0.25 0.048 0.19 0.16 0.024 —
10-SS5YJ3-S46-C4 C4 0.22 0.34 0.057 0.10 0.090 0.024 —
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model no.
Example
앬10-SS5YJ3-20-03 ······ 1 set (Manifold base) 앬10-SS5YJ3-S41-03-C4 ······ 1 set (Manifold base)
∗ 10-SYJ3123-5G-M3 ······ 2 sets (Valve) ∗ 10-SYJ3143-5LZ ······ 2 sets (Valve)
∗ SYJ3000-21-1A······ 1 set (Blanking plate assembly) ∗ SYJ3000-21-2A ······ 1 set (Blanking plate assembly)

The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

504
Manifold specifications 10-SYJ3000

Flat ribbon cable manifold


• Multiple valve wiring is Flat ribbon cable manifold specifications
simplified through the

Air cylinder
Model Type 21P Type 32P
use of the flat ribbon Manifold Single base / B mount
cable connector. P(SUP) / R(EXH) Common SUP / Common EXH
Valve stations 4 to 12 stations
• Clean appearance A, B port piping Location Valve Base
specifications Direction Top Side

Rotary actuator
In the case of a flat ribbon cable type, each valve
is wired on the print board of manifold base to P, R port 1/8
allow the external wiring to be piped all together Port size
A, B port M3 x 0.5 M5 x 0.8 C4 (One-touch fitting for ø4)
with 26 pins MIL connector.
Applicable flat ribbon
cable connector Socket: 26 pins MIL type with strain relief (conforming to MIL-C-83503)

Internal wiring In common between +COM and –COM (Z type: +COM only).
Rated voltage 12, 24 VDC, 100, 110 VAC
Note) The withstand voltage specification for the wiring unit section conforms to JIS C0704, Grade 1 or

Air gripper
its equivalent.

Flow characteristics

Directional control
Type 21P Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R) Effective

valve
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C (mm2)
port b Cv b Cv
port [dm /(s·bar)]
3 [dm /(s·bar)]
3

Body ported
for internal pilot
10-SS5YJ3-21P 10-SYJ3첸23 1/8 M3 x 0.5 — — — — — — 0.9

Base mounted 10-SS5YJ3-32P-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 —
for internal pilot 10-SS5YJ3-32P-C4
10-SYJ3첸33 1/8
C4 0.25 0.18 0.059 0.3 0.27 0.075 —

Flow control
equipment
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifolds


앬10-SS5YJ3-32P-07-C4 ··1 set (Manifold base) ∗ SYJ3000-21-4A ··1set (Blanking plate assembly)

control equipment
∗ 10-SYJ3133-5LOU ····3 sets (Valve) ∗ SY3000-37-28A ··3 sets (Connector assembly)

Filter, Pressure
∗ 10-SYJ3233-5LOU ····3 sets (Valve) ∗ SY3000-37-29A ··3 sets (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

How to Order Connector


How to Order Valves Assemblies

Fittings & Tubing


Light/Surge voltage suppressor
Rated voltage Z With light/surge voltage suppressor For 12, 24 VDC
5 24 VDC With light/surge voltage
U For single solenoid SY3000-37-28A
6 12 VDC suppressor (Non-polar type)
Double solenoid 3
Clean series Note) Z: Positive common specifications only.
position type
SY3000-37-29A

2
Air preparation

For DC10 SYJ3 1 3 5 LO U


equipment

3 For 100 VAC


For single solenoid SY3000-37-46A
2
For AC10 SYJ3 1 3 3 1 LO Z Double solenoid 3
position type
SY3000-37-47A
Type of actuation
1 2 position single A, B port size
Pressure switch

2 2 position double Symbol Port size 110 VAC (115 VAC)


3 3 position closed center Nil Base mounted For single solenoid SY3000-37-54A
4 3 position exhaust center M3 M3 x 0.5 Double solenoid 3
3 position pressure center SY3000-37-55A
5 position type
Rated voltage
1 100 VAC Note) In the case of flat ribbon cable type,
3 110 VAC(115 VAC) "U" and "Z" types are for DC
Clean gas filter

specifications and "Z" type is for AC


Manual override specifications. "Z" type for DC is
positive common specifications
Nil Non-locking push type
only. For other combinations,
D Push-turn locking slotted type please contact SMC.
E Push-turn locking lever type

505
Manifold specifications 10-SYJ3000

Common SUP / Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20 (5 port / Body ported) How to Order Applicable solenoid valve


10-SYJ3첸23-첸첸첸첸-M3
A, B port 10--SS5YJ3--20-- 05
M3 x 0.5 Applicable blanking plate
Clean series assembly
Stations SYJ3000-21-1A
02 2 stations

P port : :
R port
M5 x 0.8 M5 x 0.8 20 20 stations

Type 31 (4 port / Base mounted) How to Order Applicable solenoid valve


10-SYJ3첸33-첸첸첸첸
Type S31 Single solenoid coil is located on
(the same side of A and B ports. ) 10--SS5YJ3--
Type 31 31-- 05 --M3 Applicable blanking plate
Clean series assembly
SYJ3000-21-2A
Valve mounting direction
Manifold stations
R port Single solenoid coil is located on 02 2 stations
R port Nil
M5 x 0.8 A, B port the opposite side of A and B ports.
M5 x 0.8 : :
A, B port M3 x 0.5 P port Single solenoid coil is located on
P port S 20 20 stations
M3 x 0.5 the same side of A and B ports.
M5 x 0.8
M5 x 0.8

Type 32 (4 port / Base mounted) How to Order

Type 32 Type S32 10--SS5YJ3-- 32-- 05 -- M5


(Single solenoid coil is located on
the same side of A and B ports. ) Clean series
Manifold stations
P, R port thread type
Valve mounting direction 02 2 stations
Single solenoid coil is located on Nil Rc
Nil : :
the opposite side of A and B ports. F G
20 20 stations
Single solenoid coil is located on N NPT
R port R port S A, B port size
the same side of A and B ports.
1/8 1/8 T NPTF
A, B port M5 M5 x 0.8
A, B port P port P port
M5 x 0.8, C4 1/8 C4 One-touch fitting for ø4
M5 x 0.8, C4 1/8
N3 One-touch fitting for ø5/32"

Type 41 (5 port / Base mounted) How to Order Applicable solenoid valve


10-SYJ3첸43-첸첸첸첸
Type 41 Type S41
10--SS5YJ3-- 41-- 05 -- C4 Applicable blanking
Single solenoid coil is located on
( the same side of A and B ports. ) Clean series
Manifold stations
plate assembly
R port SYJ3000-21-2 A
1/8 P port
Valve mounting direction 02 2 stations
1/8 Single solenoid coil is located on : :
Nil
the opposite side of A and B ports.
20 20 stations
Single solenoid coil is located on P, R port thread type
S
the same side of A and B ports. A, B port size Nil Rc
P port
1/8 R port M5 M5 x 0.8 F G
A, B port 1/8 C4 One-touch fitting for ø4
A, B port N NPT
M5 x 0.8, C4 M5 x 0.8, C4 N3 One-touch fitting for ø5/32" T NPTF

Common SUP / Individual EXH Note) For more than 10 stations, supply air to both sides of P port.

Type 46 (5 port / Base mounted) How to Order Applicable solenoid valve


10-SYJ3첸43-첸첸첸첸
Type 46 Type S46 10--SS5YJ3-- 46-- 05 -- M5
Single solenoid coil is located on Applicable blanking
( the same side of A and B ports. ) Clean series
plate assembly
R1, R2 port Manifold stations SYJ3000-21-2A
M5 x 0.8 Valve mounting direction 02 2 stations
Single solenoid coil is located on : :
Nil P port thread type
the opposite side of A and B ports.
R1, R2 port 20 20 stations
Single solenoid coil is located on Nil Rc
M5 x 0.8 S A, B port size
P
the same side of A and B ports. F G
A

B
A, B port M5 M5 x 0.8
A, B port P port N NPT
M5 x 0.8, C4
M5 x 0.8, C4 1/8 C4 One-touch fitting for ø4 T NPTF
P port
N3 One-touch fitting for ø5/32"
1/8

506
Manifold specifications 10-SYJ3000

Flat ribbon cable manifold

Common SUP / Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Air cylinder
Applicable solenoid valve
Type 21P How to Order
Refer to page 505.
A, B port
M3 x 0.5 10--SS5YJ3--21P-- 07 -- Applicable connector
P, R port assembly
Clean series thread type Refer to page 505.
Manifold stations

Rotary actuator
Nil Rc Applicable blanking
04 4 stations
00F G plate assembly
: :
P port
R port
00N NPT SYJ3000-21-3A
12 12 stations
1/8 1/8 00T NPTF (With dust cap)

Type 32P How to Order Applicable solenoid valve


Refer to page 505.
A, B port 10--SS5YJ3--32P-- 07 -- C4 Applicable connector

Air gripper
M5 x 0.8, C4 assembly
Clean series P, R port
thread type Refer to page 505.
Manifold stations A, B port size Nil Rc Applicable blanking
04 4 stations M5 M5 x 0.8
plate assembly
F G
SYJ3000-21-4A
P port : : C4 One-touch fitting for ø4 N NPT
R port (With dust cap)

Directional control
1/8 1/8 12 12 stations N3 One-touch fitting for ø5/32" T NPTF

valve
Mixed installation of the 10-SYJ300 and the 10-SY3000 valves on the same manifold
Series 10-SYJ300 valves can be mounted on the manifolds for 10-SY3000.

Flow control
equipment
q 10-SS5YJ3-20, 10-SS5YJ3-21P (10-SYJ300 3 port valve)
The 3 port valve can be used by simply sealing off the unused "R"
port with rubber plug, SYJ3000-33-1.
Applicable solenoid valves: Type 10-SYJ312M
Type 10-SYJ322M
(10-SYJ300 3 port valve)

control equipment
Filter, Pressure
w 10-SS5YJ3-31/-S31, 10-SS5YJ3-32/-S32,
10-SS5YJ3-46/-S46, 10-SS5YJ3-32P
The 3 port valve can be used without modification. Plug (SYJ3000-33-1) Plug (SYJ3000-33-1)
The A port of the valve will flow out of the B Seal the unused "R"
Seal the unused "R"
port of the manifold. port on the end cover port on the end cover
Applicable solenoid valve: Type 10-SYJ314M side of the manifold. side of the manifold.
Type 10-SYJ324M

Fittings & Tubing


e 10-SS5YJ3-41/-S41
The 3 port valve can be used by simply sealing off
the unused "R" port with rubber plug (SYJ3000-33-1).
The A port of the valve will flow out of the B port of the
manifold.
Applicable solenoid valve: Type 10-SYJ314M
Type 10-SYJ324M
Air preparation
equipment

Caution
Mounting screw tightening torque
M1.7: 0.12N·m Type 10-SS5YJ3-20 Type 10-SS5YJ3-41

Use caution to the assembly orientation for


"B" port becomes "A" port of 3 port valve.
Pressure switch

solenoid valves, gasket, and optional parts.


Clean gas filter

507
Manifold specifications 10-SYJ3000

<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base
5 port body ported 4 port base mounted 5 port base mounted
(Type 10-SYJ3첸23) (Type 10-SYJ3첸33) (Type 10-SYJ3첸43)
Round head combination screw
SY100-33-3
(M1.7 x 17, matt nickel plated)
Applicable manifold base Applicable manifold base Applicable manifold base
Type 10-SS5YJ3-31 Type 10-SS5YJ3-41
Type 10-SS5YJ3-20
Type 10-SS5YJ3-S31 Type 10-SS5YJ3-S41 Manifold
Type 10-SS5YJ3-21P Manifold
Type 10-SS5YJ3-32 base Type 10-SS5YJ3-46 base
Manifold base Type 10-SS5YJ3-S32 Type 10-SS5YJ3-S46
Type 10-SS5YJ3-32P
A mark A mark Protrusion for
positioning Manifold gasket
A
Manifold gasket A
Manifold gasket
SYJ3000-14-7 SYJ3000-14-6 SYJ3000-14-2
Note) Please insert the protrusion for positioning of
the manifold gasket into the hole of the valve
body completely.

Combination of blanking plate assembly and manifold base Difference between types 10-SYJ3첸33 and 10-SYJ3첸43
Blanking plate assembly Blanking plate assembly Type 10-3첸33 (4 port) Type 10-3첸43 (5 port)
SYJ3000-21-1A SYJ3000-21-2A
Round head
combination screw
Blanking plate Steel ball is driven in

Blanking plate

A mark A mark

Manifold gasket Manifold gasket

Applicable base Applicable base sub-plate


Type SS5YJ3-20 manifold base Type 10-SS5YJ3-41
Type 10-SS5YJ3-S41
Type 10-SS5YJ3-46
Type 10-SS5YJ3-S46
Manifold
Type 10-SS5YJ3-31 base
Type 10-SS5YJ3-S31 Configuration of this surface is different
Type 10-SS5YJ3-32
Type 10-SS5YJ3-S32
Note) The SYJ3000-14-2 manifold gasket can be used for
10-SS5YJ3-31/-S31 and 10-SS5YJ3-32/-S32 manifold
bases.

Blanking plate assembly Blanking plate assembly


SYJ3000-21-4A SYJ3000-21-3A
Round head
combination screw Round head
combination screw

Blanking plate
Blanking plate A mark
A mark

Manifold gasket
Manifold gasket

Dust cap Dust cap

Caution
Mounting screw tightening torque
M1.7: 0.12N·m
Applicable base Applicable base Use caution to the assembly orientation for
Type 10-SS5YJ3-32P manifold base Type 10-SS5YJ3-21P manifold base solenoid valves, gasket and option parts.

508
Manifold specifications 10-SYJ3000
Type 20 manifold: Top ported / 10-SS5YJ3-20- Stations ∗ [ ]: AC

(Lead wire length)


Grommet (G)

Approx. 300

Air cylinder
(Pitch)
P = 10.5 12.5
Manual

Rotary actuator
override

4 5

3.7
15.8

1.5
91.7[96.1]

78.8[83.2]
7 10
R
R

A A A A A

14
19.5

11 10
30.7
31.5

29
52.9[55.1]
53.7[55.9]

B B B B B

R
R

Air gripper
2-ø3.5 M5 x 0.8
(For mounting) (P, R port)

M3 x 0.5
(A, B port)
L2 3.5

Directional control
L1

valve
(Station n) (Station 1)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+

Flow control
42[49]

equipment
26.6
13.5

control equipment
Filter, Pressure
L plug connector (L) M plug connector (M) M8 connector (WO)
(Lead wire length)
Approx. 300

42[49]
26.6

Fittings & Tubing


M8 x 1
Approx. 300 53.1[60.1]
(Lead wire length)
1.5

1.5
1.5

Air preparation
111.5[115.9]

91.9[96.3]

equipment
109.7
98.6[103]

94.9
79[83.4]

96.8

82
53[55.2]
62.8[65]

54.5
61.9

Pressure switch
0.8

0.8
0.8
0.8

29
46.5

∗ Refer to page 563 for dimensions


Clean gas filter

with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 35.5 46 56.5 67 77.5 88 98.5 109 119.5 130 140.5 151 161.5 172 182.5 193 203.5 214 224.5
L2 28.5 39 49.5 60 70.5 81 91.5 102 112.5 123 133.5 144 154.5 165 175.5 186 196.5 207 217.5

509
Manifold specifications 10-SYJ3000
Type 31 manifold: Side ported / 10-SS5YJ3-31- Stations -M3 ∗ [ ]: AC

Grommet (G) Pilot valve of single solenoid


valve is located on the same
Type S3: Side ported side of A and B ports.
(Lead wire length)
Approx. 300

10-SS5YJ3-S31- Stations -M3


L1
3.5 L2

2-ø3.5
(For mounting) Manual
override
M5 x 0.8

5.2
7.5

17.3
(P, R port)
52.2[54.4]

51.4[53.6]

3
91.7[96.1]

78.8[83.2]
78.8[83.2]

13.5
A A A A A
B B B B B

R
R

R
29.2
91.7[96.1]

R
30

29.2
25
12
25

51.4[53.6]
30
52.2[54.4]
3 13.5

B B B B B

P
P

P
P

A A A A A
17.3

7.5
5.2

Manual override 2-ø3.5


(Pitch) (For mounting)
(Pitch) P = 10.5 9
12.5 P = 10.5 L2 3.5
L1

(Station 1) (Station n) (Station n) (Station 1)


(Light/surge voltage (Light/surge voltage suppressor)
suppressor)
43.5[50.5]

-+ -+ -+ -+ -+ -+ -+
28.1

A A B B
15

15
12

12

B B A A
3
3

1 (Pitch) (Pitch) 1
13.5 P = 10.5 M3 x 0.5 M3 x 0.5 P = 10.5 14.5
(A, B port) (A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1 48
30.5
0.8

0.8

0.8
0.8
61.3[63.5]

51.5[53.7]

60.4

53
98.6[103]
111.5[115.9]

79[83.4]
91.9[96.3]

96.8

82
109.7

94.9

Approx. 300 54.6[61.6]


(Lead wire length)
(Lead wire length)

28
Approx. 300

43.4[47.3]

∗ Refer to page 563 for dimensions


with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 35.5 46 56.5 67 77.5 88 98.5 109 119.5 130 140.5 151 161.5 172 182.5 193 203.5 214 224.5
L2 28.5 39 49.5 60 70.5 81 91.5 102 112.5 123 133.5 144 154.5 165 175.5 186 196.5 207 217.5

510
Manifold specifications 10-SYJ3000
C4
Type 32 manifold: Side ported / 10-SS5YJ3-32- Stations -M5, N3 첸 ∗ [ ]: AC

(Lead wire length)


Approx. 300
Grommet (G) C4첸(With built-in One-touch fitting)
L1 N3
4 L2 Manual override
M5 10

Air cylinder
2-ø4.5
(For mounting)

36.5
1/8

17
10

53.4[55.6]
54.2[56.4]
(P, R port)

78.8[83.2]
91.7[96.1]

31.5
3.2 31.2
R

12.5
(4.4)
B B B B B
32

17
1 16
P
P

A A A A A

7.5

Rotary actuator
15.3

(Station 1) (Station n)
L1
(Pitch) 4.5 L2
15.5 P = 10.5 (Light/surge voltage
15.5
suppressor)
(Station 1) (Station n) -+ -+

(Light/surge voltage suppressor)


A A

20
15
5
48.5[55.5]

B B
-+ -+

1.5 (Pitch) One-touch fitting


33.1

Air gripper
A A 16 P = 10.5 (A, B port)
20
15

B B
Applicable tubing O.D.:
5

1 (Pitch) M5 x 0.8 ø4 and ø5/32"


16.5 P = 10.5
(A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)

Directional control
M8 x 1 53
0.8

0.8
35.5
0.8

valve
0.8
63.3[65.5]

53.5[55.7]
111.5[115.9]

62.4
98.6[103]

79[83.4]
91.9[96.3]

55
96.8
109.7

82
94.9
1

Flow control
equipment
(Lead wire length)
Approx. 300

Approx. 300 59.6[66.6]


33.1 (Lead wire length)
48.4[55.4]
∗ Refer to page 563 for dimensions with
connector cable.

control equipment
Filter, Pressure
Pilot valve of single solenoid valve is C4
Type S32 manifold: Side ported located on the same side of A and B ports. / 10-SS5YJ3-S32- Stations -M5, N3 첸
L1 C4 첸(With built-in One-touch fitting)
M5 L2 4 N3

Fittings & Tubing


Manual
12.3

override 10
15.5

34.2 0.2
91.7[96.1]

78.8[83.2]

36.5
17
56.4[58.6]
57.2[59.4]

31.5
R

A A A A A
35

B B B B B
P
P

12.5
(4.4)

2-ø4.5
Air preparation

(Pitch) (Station n) (Station 1)


equipment

(For mounting) P = 10.5 15.5 L1


(Station n) (Station 1) L2 4.5
(Light/surge voltage suppressor)
15.5
(Light/surge voltage suppressor) -+ -+ -+ -+ -+

-+ -+ -+ -+ -+
B B
20
15
5

A A
B B
20

1
5
15

M5 x 0.8 (Pitch)
Pressure switch

A A

17.5 One-touch fitting


(A, B port) P = 10.5 (A, B port)
(Pitch) 1.5
P = 10.5 18
Applicable tubing O.D.:
ø4 and ø5/32"
SS5YJ3-32,S32- Stations -M5
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 41.5 52 62.5 73 83.5 94 104.5 115 125.5 136 146.5 157 167.5 178 188.5 199 209.5 220 230.5
Clean gas filter

L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5
10-SS5YJ3-32,S32- Stations -C4
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 42.5 53 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5
L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5

511
Manifold specifications 10-SYJ3000
Type 41 manifold: Side ported / 10-SS5YJ3-41- Stations -M5, C4
N3 첸 ∗ [ ]: AC

C4 첸 (With built-in One-touch fitting)

(Lead wire length)


Approx. 300
Grommet (G) (Pitch) N3
M5 16 P = 10.5 1/8
10 (P port)
Manual override
1/8

36.4
10 10
61.7[63.9]

60.9[63.1]
(P port)

21.4
78.8[83.2]
91.7[96.1]

R
39.5 B B B B B

38.7

36.5
18

4.3

21.5
R

(4.4)
P
A A A A A
3
11.5

7.8

1/8 (Station 1) (Station n)


(R port) 2-ø4.5 4 L2 (Light/surge voltage suppressor)
(For mounting) L1
(Station 1) (Station n) -+ -+

(Light/surge voltage suppressor)


A A

20
15
48.5[55.5]

B B

5
-+ -+

2 One-touch fitting
33.1

(Pitch)
A A
17 P = 10.5 (A, B port)
20
15
5

B B Applicable tubing O.D.:


2 ø4 and ø5/32"
(Pitch) M5 x 0.8
17 P = 10.5
(A, B port)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1 53
0.8

35.5

0.8
0.8

0.8
70.8[73]

61[63.2]

69.9
111.5[115.9]
98.6[103]

62.5
79[83.4]
91.9[96.3]

96.8
109.7

82
94.9
(Lead wire length)

Approx. 300 59.6[66.6]


Approx. 300

(Lead wire length)


33.1
48.5[55.5]
∗ Refer to page 563 for dimensions with
connector cable.

Pilot valve of single solenoid valve is C4


Type S41 manifold: Side ported located on the same side of A and B ports. 10-SS5YJ3-S41- Stations -M5, N3 첸
(Pitch)
P = 10.5 16 C4첸(With built-in One-touch fitting)
M5 N3
Manual
override
32.2 2.2
91.7[96.1]

33 14.3

78.8[83.2]

1/8
10
(P port)
54.4[56.6]

A A A A A
R
55.2[57.4]

33.5
36.5
P

B B B B B
R

36.4
21.4

2-ø4.5
(4.4)

L2 4 (For mounting)
L1
(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+

-+ -+ -+ -+ -+

B B
20
15

B B
20

A A
15

A A
5

2 (Pitch) 2
M5 x 0.8 (Pitch) One-touch fitting
P = 10.5 15
P = 10.5 15 (A, B port)
(A, B port)
Applicable tubing O.D.:
ø4 and ø5/32"
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5

512
Manifold specifications 10-SYJ3000
Type 46 manifold: Side ported / 10-SS5YJ3-46- Stations -M5, C4
N3 첸 ∗ [ ]: AC

Approx. 300
(Lead wire length)
Grommet (G) C4 첸 (With built-in One-touch fitting)
M5 (Pitch) N3

Air cylinder
14.5 P = 10.5
1/8
10 (P port)
Manual
override
1/8

34.9
10

59.9[62.1]
60.7[62.9] (P port)

18.9
78.8[83.2]
91.7[96.1]

B B B B B
38.5

37.7

35
3.3
P

(4.4)

Rotary actuator
19
A A A A A
10
8.8

2-ø4.5
4 L2 (For mounting) (Station 1) (Station n)
L1 (Light/surge voltage suppressor)

(Station 1) (Station n)
-+ -+
(Light/surge voltage suppressor)

Air gripper
48.5[55.5]

A A

20
15
-+ -+
B B

5
33.1

A A 1.5 (Pitch) One-touch fitting


20
15
5

B B 11.8 P = 10.5 (A, B port)


1.5 (Pitch) Applicable tubing O.D.:
11.8 P = 10.5 M5 x 0.8 ø4 and ø5/32"
(A, B port)

Directional control
L plug connector (L) M plug connector (M) M8 connector (WO)

valve
M8 x 1 53
0.8

35.5

0.8

0.8
0.8
69.8[72]

60[62.2]

68.9
111.5[115.9]
98.6[103]

61.5
79[83.4]
91.9[96.3]

Flow control
equipment
96.8
109.7

82
94.9
(Lead wire length)
Approx. 300

Approx. 300 59.6[66.6]

control equipment
Filter, Pressure
(Lead wire length)
33
48.5[55.5]
∗ Refer to page 563 for dimensions with
connector cable.

Fittings & Tubing


Pilot valve of single solenoid valve is C4
Type S46 manifold: Side ported located on the same side of A and B ports. /10-SS5YJ3-S46- Stations -M5, N3 첸
(Pitch)
P = 10.5 14.5 C4첸(With built-in One-touch fitting)
M5 N3
Manual
override
25 0.5
31.7 2.7
32.5 14.8
91.9[96.3]

1/8
78.8[83.2]

Air preparation

10
equipment

(P port)
A A A A A
53.9[56.1]
54.7[56.9]

25

35
P

B B B B B
34.9
18.9

2-ø4.5
(4.4)

L2 4 (For mounting)
L1
Pressure switch

(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)

-+ -+ -+ -+ -+
(Light/surge voltage suppressor) -+ -+ -+ -+ -+

B B
20

B B
20

15
15

A A
5

A A
5

(Pitch) 1.5 One-touch fitting (Pitch) 1.5


M5 x 0.8 P = 10.5 15.7 P = 10.5 15.7
Clean gas filter

(A, B port)
(A, B port) Applicable tubing O.D.:
ø4 and ø5/32"
Stations n 2 Stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Stations
L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5

513
Manifold specifications 10-SYJ3000

Flat ribbon cable manifold ∗ [ ]: AC

10-SS5YJ3-21P- Stations -00첸

L1
L2 4
Manual override
-+ -+ -+

M3 x 0.5 -+

(A, B port) 10
2 2

5.2
111.5[115.9]

30 17.3

7.5
7 8.5

16 3

98.6[103]
A

P
P

29.2

31.5
61.3[63.5]
62.1[64.3]

17
45.5
B

65.3
R

2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+

Triangle mark
(Pitch) 1/8
P=12.5 18.5 (P, R port)
(Station n) (Station 1)
(Light/surge voltage suppressor)
48.5[55.5]

25.6
5.8
20

28.5

Applicable connector: 26 pins MIL type


With strain relief
(Conforming to MIL-C-83503)

10-SS5YJ3-32P- Stations -M5, C4


N3 첸
C4 첸(With built-in One-touch fitting)
N3
M5 (Pitch)
P = 12.5 19.5
M5 x 0.8 1
(Pitch)
(A, B port)
5

B B
One-touch fitting (A, B port) P = 12.5 19.5
15

A
Applicable tubing O.D.: ø4 and ø5/32" 1
A

5
B B

15
20
A A

L1
L2 4
Manual override
-+ -+ -+

-+

10 10
3.2
32 15.3

7.5

(4.4)
111.5[115.9]

12.4
1

98.6[103]
16

A A A A A A
P
P

31.2

31.5
17
63.3[65.5]
64.1[66.3]

36.4

B B B B B B
R
R

65.3

17

50.4
70.2

2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+

Triangle mark
(Pitch) 1/8
P = 12.5 18.5 (P, R port) 1/8
(Station n) (Station 1) (P, R port)
(Light/surge voltage suppressor)
Applicable connector: 26 pins MIL type
With strain relief
48.5[55.5]

(Conforming to MIL-C-83503)
5.8
25.6
20

28.5 Stations n 4 Stations 5 6 7 8 9 10 11 12 Stations


L1 72.5 85 97.5 110 122.5 135 147.5 160 172.5
L2 64.5 77 89.5 102 114.5 127 139.5 152 164.5

514
Series 10-SYJ5000 Rubber seal
5 port solenoid valve

Air cylinder
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure
2 position double 0.1 to 0.7
range MPa
3 position 0.15 to 0.7
Ambient and fluid temperature -10 to 50°C (with no freezing. Refer to page 714.)

Rotary actuator
Response time ms Note 1) 2 position single, double 25 or less
(0.5 MPa) 3 position 40 or less
Max. operating 2 position single, double 5
frequency (Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the main and pilot valve
Lubrication Not required
Body ported
Mounting orientation Unrestricted

Air gripper
Impact/Vibration resistance m/s2 Note 2) 150/30
Enclosure Dustproof (∗ DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve
and armature in both energized and de-energized states every once for each condition. (Value in the initial state)

Directional control
Vibration resistance: No malfunction occurred in one sweep between 45 and 2000Hz. Test was performed in the axial direction and at the right angles
to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state)

valve
Solenoid specifications
Grommet(G), (H) , L plug connector (L),
M plug connector (M), DIN terminal (D),
Electrical entry M8 connector (W)
Base mounted
G, H, L, M, W D
JIS Symbol DC 24, 12, 6, 5, 3 24, 12
Rated coil voltage V

Flow control
equipment
AC 50/60Hz 100, 110, 200, 220
Body ported Base mounted Allowable voltage fluctuation ±10% of rated voltage ∗
(With sub-plate)
Standard 0.35 {With indicator light: 0.4 (DIN terminal with indicator light: 0.45)}
2 position single 2 position single Power consumption (W) DC
With power saving circuit 0.1 (With indicator light only)
(A) (B) (B)(A) 100V 0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)
4 2 2 4 110V 0.86 (With indicator light: 0.89) 0.86 (With indicator light: 0.97)
[115V] [0.94 (With indicator light: 0.97)] [0.94 (With indicator light: 1.07)]
Apparent power (VA) ∗ AC

control equipment
5 1 3 200V 1.18 (With indicator light: 1.22) 1.15 (With indicator light: 1.30)

Filter, Pressure
3 1
(R1) (P) (R2) (R)(P) 220V 1.30 (With indicator light: 1.34) 1.27 (With indicator light: 1.46)
2 position double 2 position double [230V] [1.42 (With indicator light: 1.46)] [1.39 (With indicator light: 1.60)]
(A) (B) (B)(A) Surge voltage suppressor Diode (DIN terminal, varistor for non-polar types)
4 2 2 4 Indicator light LED (Neon light for DIN terminal AC)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
5 1 3 3 1 ∗ For 115 and 230 VAC, the allowable voltage fluctuation is -15% to +5% of rated voltage.
(R1) (P) (R2) (R)(P) ∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please
observe the following range because they have voltage drop due to internal circuit.

Fittings & Tubing


3 position closed center 3 position closed center
(A) (B) (B)(A) S and Z types 24 VDC: -7% to +10% 12 VDC: -4% to +10%
4 2 2 4 T type 24 VDC: -8% to +10% 12 VDC: -6% to +10%

5 1 3
Built-in speed controller
(R1) (P) (R2) 3 1
(R)(P)
10-SYJ5첸53 Throttle valve characteristics ( AB →R)
앬 Built-in exhaust flow controls enable simple cylinder speed
3 position exhaust center 3 position exhaust center
adjustments.
Effective area (mm2)

(A) (B) (B)(A) 앬 When mounted on the manifold, the common exhaust discharges
Air preparation

4 2 2 4
the pilot and main valve exhaust through a common EXH port to 2
equipment

enable simple exhausting.


5 1 3 3 1
(R1) (P) (R2) (R)(P) (B) (A)
JIS Symbol 2 4 1
3 position pressure center 3 position pressure center
(A) (B) (B) (A)
4 2 2 4
3 1 (Single) 0
(R) (P) 1 2 3 4 5 6 7
Pressure switch

5 1 3
(Fully closed) (Fully open)
(R1) (P) (R2) 3 1
(R) (P)
How to order valve with Note) 앬 When using 10-SYJ5첸53 model, the speed controller
built-in speed controller must be opened more than 1 complete rotation from
fully closed in order to function properly.
Made to
10--SYJ5 53 -- -- 앬 Adjust the speed controller with a torque of 0.3 N·m
Order Made to order specifications or less.
Type of Port size
(Refer to page 557 for details.) actuation Plate fixing screw
Manual override
Clean gas filter

Clean series
Rated voltage Light/Surge voltage
Electrical entry suppressor
Note) Do not loosen plate fixing screw.

515
5 port solenoid valve Series 10-SYJ5000
Flow characteristics / Weight
Port size Flow characteristics Note 1) Weight (g) Note 2, 3)
Valve model Type of actuation 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
Grommet L/M plug DIN terminal M8 connector
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv connector
Single 46 47 68 51
2 position 0.47 0.41 0.13 0.47 0.41 0.13 74
Double 64 66 108
10-SYJ5첸23-첸-M5 Closed center M5 x 0.8 M5 x 0.8 0.49 0.44 0.13 0.44 0.40 0.12
3 position Exhaust center 0.46 0.37 0.12 0.47[0.39] 0.43[0.35] 0.13[0.10] 75 77 119 85
Pressure center 0.49[0.39] 0.51[0.38] 0.14[0.10] 0.45 0.42 0.12
Single 53 54 75 58
Body ported

2 position 0.69 0.39 0.18 0.44 0.39 0.12


Double C4 71 73 115 81
10-SYJ5첸23-첸-C4 Closed center M5 x 0.8 (One-touch 0.69 0.40 0.19 0.43 0.40 0.12
3 position Exhaust center fitting for ø4) 0.56 0.40 0.15 0.41[0.41] 0.37[0.37] 0.10[0.11] 82 84 126 72
Pressure center 0.57[0.41] 0.4[0.37] 0.15[0.10] 0.41 0.37 0.10
Single 53 54 75 58
2 position 0.70 0.36 0.19 0.47 0.40 0.12
Double C6 71 73 115 81
10-SYJ5첸23-첸-C6 Closed center M5 x 0.8 (One-touch 0.72 0.37 0.19 0.44 0.34 0.12
3 position Exhaust center fitting for ø6) 0.67 0.54 0.19 0.41[0.41] 0.38[0.38] 0.11[0.11] 82 84 126 92
Pressure center 0.82[0.44] 0.41[0.39] 0.23[0.12] 0.41 0.36 0.11
Single 80 (49) 81 (47) 102 (68) 51
Base mounted

2 position 0.79 0.21 0.19 0.83 0.32 0.21


Double 98 (64) 100 (66) 142 (108) 74
10-SYJ5첸43-첸-01 Closed center 1/8 1/8 0.80 0.28 0.18 0.86 0.34 0.20
3 position Exhaust center 0.71 0.26 0.18 1.1[0.60] 0.24[0.44] 0.26[0.18] 109 (75) 111 (77) 153 (119) 85
Pressure center 0.99[0.47] 0.29[0.38] 0.24[0.12] 0.72 0.38 0.18
Note 1) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate
Note 3) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types.

516
5 port solenoid valve Series 10-SYJ5000

How to Order
Light/Surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D

Air cylinder
Type of actuation Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
S With surge voltage suppresser S With surge voltage suppressor (Non-polar type)
1 2 position single solenoid
Z With light/surge voltage suppresser Z With light/surge voltage suppressor (Non-polar type)
2 2 position double solenoid
R With surge voltage suppresser (Non-polar type) ∗ "DOZ" is not available.
3 3 position closed center
U With light/surge voltage suppresser (Non-polar type) ∗ For AC voltage valves, there is no "S" option.
4 3 position exhaust center It is already built-in to the rectifier circuit.
5 3 position pressure center ∗ For AC voltage valves, there is no "S" option.
It is already built-in to the rectifier circuit. Bracket

Rotary actuator
∗ For "R" and "U", DC voltage is only available.
∗ Power saving circuit is only available in the "Z" type. Nil: Without bracket
F: With bracket
Rated voltage
DC specifications AC specifications (50/60Hz)
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC[115 VAC] M5 M5 x 0.8
S 5 VDC 4 220 VAC[230 VAC] C4 One-touch fitting for ø4

Air gripper
R 3 VDC ∗ For type "W첸", DC C6 One-touch fitting for ø6
∗ DC specifications voltage is only N3 One-touch fitting for ø5/32"
of type "D" and "DO" available. N7 One-touch fitting for ø1/4"
is only available with Note) The mounting bracket is
(For manifold type 20) 12 and 24 VDC. supplied unattached.

Directional control
Body ported 10 SYJ5 1 23 5 L M5

valve
Base mounted 10 SYJ5 2 43 5 L
Thread type
Clean series

Flow control
equipment
Nil Rc
Coil specifications Manual override F G
Nil Standard N NPT
Nil: Non-locking push type
With power saving circuit T NPTF
T
<For 24 and 12 VDC only>
∗ Power saving circuit is not
Port size

control equipment
Sub-plate, 40, 41, 42,
available in the case of "D",

Filter, Pressure
43 manifold
"DO" or "W첸" type. Nil: Without sub-plate

D: Push-turn locking
slotted type

Fittings & Tubing


(With gasket and screws)

01: 1/8 with sub-plate


Electrical entry
24, 12 VDC, 24, 12 VDC,
24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC 100, 110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector DIN terminal M8 connector E: Push-turn locking
Air preparation

G: Lead wire length L: With lead wire M: With lead wire MN: Without lead wire D: With connector WO: Without connector lever type
equipment

300 mm (length 300 mm) (length 300 mm) cable


–+
–+

–+
–+

Pressure switch

H: Lead wire length LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector W첸: With connector
600 mm cable Note 1)

–+
Clean gas filter
–+

Note 1) Be sure to enter a symbol of the cable


length with reference to page 562.
∗ "LN", "MN" types: with 2 sockets.
∗ DIN terminal type "Y" conforming to EN-175301-803C (former DIN43650C) is also available. For details, refer to page 557.
∗ For connector cable of M8 connector, refer to page 562.

517
5 port solenoid valve Series 10-SYJ5000

How to Order Pilot Valve Assembly How to Order Connector Assembly for L/M Plug Connector

10 V111 5 G For DC :SY100-30-4A-


Clean series
Light/Surge voltage suppressor For 100 VAC :SY100-30-1A-
Coil specifications Nil Without light/surge voltage suppressor
Nil Standard S With surge voltage suppressor For 200 VAC :SY100-30-2A-
With power saving circuit Z With light/surge voltage suppressor
T
<24 and 12 VDC only> R With surge voltage suppressor (Non-polar type) For other voltages of AC :SY100-30-3A-
∗ Power saving circuit is U With light/surge voltage suppressor (Non-polar type)
not available in the ∗ For AC voltage valves, there is no
case of "W첸" type. "S" option. It is already built-in to the Without lead wire :SY100-30-A
rectifier circuit. (With connector and 2 of sockets only)
∗ For "R" and "U", DC voltage is only
Rated voltage available. Lead wire length
∗ Power saving circuit is only available
5 24 VDC in the "Z" type. Nil 300mm
6 12 VDC 6 600mm
V 6 VDC
Electrical entry
10 1000mm
S 5 VDC G Grommet (Lead wire length 300 mm)
15 1500mm
R 3 VDC H Grommet (Lead wire length 600 mm)
20 2000mm
1 100 VAC 50/60Hz L With lead wire
L plug 25 2500mm
2 200 VAC 50/60Hz LN connector Without lead wire
30 3000mm
110 VAC 50/60Hz LO Without connector
3 50 5000mm
[115 VAC 50/60Hz] M With lead wire
M plug
220 VAC 50/60Hz MN connector Without lead wire
4 MO Without connector
[230 VAC 50/60Hz]
∗ For type "W첸", DC WO M8 Without connector cable
voltage is only W첸 connector Without connector cable Note 1)
available. ∗ For connector cable of M8 connector,
refer to page 562.
How to Order M8 Connector Cable
Note 1) Be sure to enter a symbol of the
cable length with reference to
page 562. V100-49-1-

10 V115 5 D Cable length


1 300mm
Clean series 2 500mm
3 1000mm
Rated voltage
4 2000mm
5 24 VDC
Light/surge voltage suppressor 7 5000mm
6 12 VDC
1 100 VAC 50 60 Hz Nil Without light/surge voltage suppressor
2 200 VAC 50 60 Hz S With surge voltage suppressor (Non-polar type)
110 VAC 50 60 Hz Z With light/surge voltage suppressor (Non-polar type)
3
[115 VAC 50 60 Hz] ∗ "DOZ" is not available.
50 60 Hz
∗ For AC voltage valves, there is no "S" option. It is
220 VAC
4 50 60 Hz]
already built-in to the rectifier circuit.
[230 VAC
∗ DC specifications Electrical entry
of type "D" and D With connector
DIN
"DO" is only
DO terminal Without connector
available with 12
and 24 V DC. Note) Do not replace 10-V111 (G, H, L, M,
∗ Power saving circuit W) to 10-V115 (DIN terminal) and
is not available in vice versa when replacing pilot
the case of "D" or valve assembly only.
"DO" type.

518
5 port solenoid valve Series 10-SYJ5000

2 position single ∗ [ ]: AC

G
Grommet (G), (H):10- SYJ5123-첸 첸첸-M5 H With bracket
G
10-SYJ5123-첸 H 첸첸-M5-F

Air cylinder
37
G: Approx. 300
63.1[65.3] H: Approx. 600 2-ø3.5 30 3.5
(Lead wire length) (For mounting)
41
19.5

18
25
-+

Rotary actuator
11

19.7
5

A B

35.1[42.1]
M5 x 0.8 10 Manual override
(A, B port) 19 2-ø2.6
(For manifold mounting)

63.1[65.3]
2-M3 x 0.5 (Light/surge voltage suppressor)

Air gripper
(Mounting screw)

-+
18

23
20

(Bracket)

2.3
28.1[35.1]
2.5

12.7
10.6 11 2-ø2.6 Built-in One-touch Fitting:

Directional control
3.5 4 (For mounting) G C4,N3
10-SYJ5123-첸 H 첸첸- C6,N7 (-F)

valve
19.5

3.5
A B
R1 P
16

15

R2 10.6 One-touch fitting

Flow control
M5 x 0.8 21 (3.2)

equipment
(A, B port)
(P, R1, R2 port) Applicable tubing O.D.: ø4 and ø5/32"
: ø6, ø1/4"
32.3

control equipment
(2.3)

Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5123-첸L첸첸-M5(-F) 10-SYJ5123-첸M첸첸-M5(-F) 10-SYJ5123-첸D첸첸-M5(-F) 10-SYJ5123-첸WO첸첸-M5(-F)

Fittings & Tubing


(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7
MAX.10

28.1[35.1] 60.9
53.4
12.7
42.1
M8 x 1 32.6
Air preparation

15.1
equipment

Approx. 300 39.2[46.2]


(Lead wire length) Pg7
73[75.2]

63.2[65.4]

82.1

83

72.1
58.2

64.7

3 3 3 3
42.2

Pressure switch
19.5

19.5

19.5
11
11
11

19.5
11

20 2-ø2.6 20 2-ø2.6 20 2-ø2.6


(2.3)

(2.3)

(2.3)

20 2-ø2.6
(2.3)

23 (For mounting) (For mounting) 23 (For mounting)


23 23 (For mounting)
27
Clean gas filter

∗ Refer to page 563 for dimensions


with connector cable.

519
5 port solenoid valve Series 10-SYJ5000

2 position double ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ5223-첸 H 첸첸-M5 Built-in One-touch fitting
10-SYJ5223-첸 GH 첸첸-C4,N3
C6,N7

G: Approx. 300
87.2[91.6] H: Approx. 600
43 (Lead wire length)

3.5
11
5

A B A B

10 Manual override 10.6


M5 x 0.8 19 2-ø2.6
(A, B port) (For manifold mounting)

One-touch fitting

(3.2)
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D.: ø4 and ø5/32"
        : ø6, ø1/4"

32.3
-+
23
20

12.7
28.1[35.1]
3

11 2-ø2.6
(For mounting)

R1 P
15

R2
M5 x 0.8 21
(P, R1, R2 port)

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5223-첸L첸첸-M5 10-SYJ5223-첸M첸첸-M5 10-SYJ5223-첸D첸첸-M5 10-SYJ5223-첸WO첸첸-M5
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7
MAX.10

28.1[35.1] 60.9
12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2[46.2]
(Lead wire length)
Pg7

20 20 20 20
107[111.4]

3 3 3
87.4[91.8]

3
105.2
125.2

90.4
77.4

45.4

127

11
11

11
11

23
2-ø2.6 2-ø2.6 2-ø2.6
(For mounting) (For mounting) (For mounting)

23
23
23
27
2-ø2.6
(For mounting)

∗ Refer to page 563 for dimensions


with connector cable.

520
5 port solenoid valve Series 10-SYJ5000
3 position closed center / exhaust center / pressure center ∗ [ ]: AC

3
Grommet (G), (H): 10-SYJ5 45 23-첸GH 첸첸-M5 Built-in One-touch fitting:
3
10-SYJ5 45 23-첸GH 첸첸- C4,N3

Air cylinder
C6,N7

G: Approx. 300
103.2[107.6] H: Approx. 600
44.2[46.4] (Lead wire length)
36.9 22.1 44.2[46.4]

3.5
11
5

Rotary actuator
A B A B

M5 x 0.8 10 Manual override 10.6


(A, B port) 19
2-ø2.6
(For manifold mounting)

One-touch fitting

(3.2)
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D: ø4 and

Air gripper
ø5/32"

32.3
: ø6, ø1/4"
-+
23
20

12.7
28.1[35.1]
3

11 2-ø2.6
(For mounting)

Directional control
valve
R1 P
15

R2
M5 x 0.8 21
(P, R1, R2 port)

Flow control
equipment
control equipment
Filter, Pressure
L plug connector
3
(L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3
10-SYJ5 5 23-첸L첸첸-M5
4 10-SYJ5 45 23-첸M첸첸-M5 10-SYJ5 45 23-첸D첸첸-M5 10-SYJ5 45 23-첸WO첸첸-M5
(Lead wire length)

Fittings & Tubing


Approx. 300

Applicable cable O.D


ø3.5 to ø7
MAX.10

28.1[35.1] 60.9
12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2[46.2]
(Lead wire length)
Air preparation

Pg7
equipment
54.1[56.3]

44.3[46.5]

64.1
63.2

53.2
45.8
39.3

20 20 20 20
23.3

3 3 3 3
103.4[107.8]
123[127.4]

11
11

11
141.2

121.2
143
11
38.1

23 2-ø2.6 23 2-ø2.6 23 23
Pressure switch
54.1

60.6

(For mounting) (For mounting) 2-ø2.6 2-ø2.6


(For (For
mounting) mounting)

27
Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

521
5 port solenoid valve Series 10-SYJ5000

2 position single ∗ [ ]: AC

G
Grommet (G), (H): 10-SYJ5143-첸 H 첸첸-01첸 Built-in speed controller:
G
10-SYJ5153-첸 H 첸첸-01첸

MAX.13.5
1/8 19.4 10.3
17 11.5
(A, B port)

8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A

24
B

R P

G: Approx. 300 41 0.5


H: Approx. 600 63.6[65.8]
(Lead wire length)

(Light/surge voltage suppressor)


50.1[57.1]

-+
45

8.5
34.7

21.5

15 17 17
24 1/8 45.5
32 (P, R port)

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5143-첸L첸첸-01첸 10-SYJ5143-첸M첸첸-01첸 10-SYJ5143-첸D첸첸-01첸 10-SYJ5143-첸WO첸첸-01첸
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7
82.9
MAX.10

50.1[57.1] 75.4
34.7 64.1
49 54.6 M8 x 1
37.1
61.2[68.2] Approx. 300
(Lead wire length) Pg7
6 6 6 6
73.5[75.7]

63.7[65.9]

83.5

82.6

65.2
72.6
58.7
45.5

45.5

45.5

45.5
17 17

17 17

17 17

17 17
42.7
0.5

0.5
0.5

6 6 6 6
0.5

8.5 8.5 8.5 8.5


21.5 21.5 21.5 21.5

∗ Refer to page 563 for dimensions with connector cable.

522
5 port solenoid valve Series 10-SYJ5000

2 position double ∗ [ ]: AC

Grommet (G), (H): 10-SYJ5243-첸GH 첸첸-01첸 Built-in speed controller:


10-SYJ5253-첸 GH 첸첸-01첸

Air cylinder
1/8 17 11.5
(A, B port)

MAX.13.5
8.5
19.4 10.3

Rotary actuator
2-ø4.3
(For mounting)
37.5 4
Manual override
B A

24
B

Air gripper
R P

41.5 1.5
G: Approx. 300 23.6[25.8]
H: Approx. 600 87.2[91.6]
(Lead wire length)

Directional control
(Light/surge voltage suppressor)

valve
50.1[57.1]

-+
45
34.7

8.5
21.5

Flow control
15 17 17

equipment
24 1/8 45.5
32 (P, R port)

control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5243-첸L첸첸-01첸 10-SYJ5243-첸M첸첸-01첸 10-SYJ5243-첸D첸첸-01첸 10-SYJ5243-첸WO첸첸-01첸

Fittings & Tubing


Applicable cable O.D
(Lead wire length)

ø3.5 to ø7
Approx. 300

82.9
MAX.10

50.1[57.1] 75.4
34.7 64.1
49 54.6
M8 x 1
61.2[68.2] Approx. 300 37.1
Air preparation
equipment

(Lead wire length) Pg7


6 6 6 6
107[111.4]

65.2
87.4[91.8]
58.7
45.5

45.5

45.5

45.5
125.2

105.2
17 17

17 17

17 17

17 17
42.7
127

2.7

Pressure switch
18.7

6 6 6 6
25.2
32.6
42.6

8.5 8.5 8.5


43.5

8.5
21.5
23.7[25.9]

21.5 21.5 21.5


33.5[35.7]

Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

523
5 port solenoid valve Series 10-SYJ5000

3 position closed center / Exhaust center / Pressure center ∗ [ ]: AC


3
Grommet (G), (H): 10-SYJ5 45 43-첸GH 첸첸-01첸 Built-in speed controller:
3
10-SYJ5 45 53-첸 GH 첸첸-01첸

1/8 17 11.5

MAX.13.5
(A, B port)
19.4 10.3

8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A

24
B

R P

42.1 16.9
39[41.2]
G: Approx. 300
H: Approx. 600 103.2[107.6]
(Lead wire length)

(Light/surge voltage suppressor)


50.1[57.1]

-+
45
34.7

21.5

15 17 17
8.5

1/8
24 45.5
(P, R port)
32

L plug connector
3
(L): M plug connector
3
(M): DIN Terminal
3
(D): M8 connector
3
(WO):
10-SYJ5 45 43-첸L첸첸-01첸 10-SYJ5 45 43-첸M첸첸-01첸 10-SYJ5 45 43-첸D첸첸-01첸 10-SYJ5 45 43-첸WO첸첸-01첸
Applicable cable O.D.
(Lead wire length)

ø3.5 to ø7
Approx. 300

82.9
MAX.10

50.1[57.1] 75.4
64.1
34.7
49 54.6 M8 x 1
61.2[68.2] Approx. 300 37.1
(Lead wire length) Pg7
6 6 6 6
65.8
59.3

103.4[107.8]
123[127.4]
45.5

45.5

45.5

45.5
43.3
17 17

17 17

17 17

17 17
141.2

121.2
143

18.1

6 6 6 6
48.9[51.1]

34.1

40.6

8.5 8.5 8.5 8.5


48
58.9

58

21.5 21.5 21.5 21.5


39.1[41.3]

∗ Refer to page 563 for dimensions with connector cable.

524
Series10-SYJ5000 Manifold specifications

Air cylinder
Manifold standard

Manifold specifications

Model Type 20 Type 40 Type 41 Type 42 Type 43

Rotary actuator
Manifold type Single base / B mount

P (SUP) / R (EXH) Common SUP / Common EXH

Valve stations 2 to 20 stations


A, B port piping Location Valve Base Base
specifications Direction Top Bottom Side

Air gripper
P, R port 1/8 1/4 1/8
Port size M5 x 0.8 1/8, C6
C4 (One-touch
A, B port C4 (One-touch fitting for ø4) M5 x 0.8 (One-touch
C6 (One-touch fitting for ø6) fitting for ø6) fitting for ø4)

Directional control
Flow characteristics

valve
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3(A/B→R)
Manifold model
1(P), 5/3(R) 2(B), 4(A) C C
port port [dm3/(s·bar)] b Cv [dm3/(s·bar)] b Cv
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
10- SS5YJ5-20 10-SYJ5첸23 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
for internal pilot

Flow control
equipment
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
10-SS5YJ5-40 1/8 M5 x 0.8 0.55 0.35 0.15 0.64 0.26 0.16
10-SS5YJ5-41 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
Base mounted
10-SS5YJ5-42-01 10-SYJ5첸43 1/4 1/8 0.74 0.22 0.18 0.82 0.31 0.21
for internal pilot
10-SS5YJ5-42-C6 1/4 C6 0.71 0.24 0.17 0.8 0.29 0.20
10-SS5YJ5-43 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19

control equipment
Note) Value at manifold base mounted, 2 position single operating

Filter, Pressure
How to Order Manifold (Example)

Fittings & Tubing


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model number.
Example 10-SS5YJ5-20-03 ············· 1 set (Manifold base)
∗ 10-SYJ5123-5G-M5 ·········· 2 sets (Valve)
∗ SYJ5000-21-4A ················ 1 set (Blanking plate assembly)
Air preparation

10-SS5YJ5-43-03-C4 ······· 1 set (Manifold base)


equipment

∗ 10-SYJ5143-5LZ ·············· 1 set (Valve)


∗ 10-SYJ5243-5LZ ·············· 1 set (Valve)
∗ SYJ5000-21-4A ················ 1 set (Blanking plate assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.


Pressure switch
Clean gas filter

525
Manifold specifications 10-SYJ5000

Flat ribbon cable manifold


• Multiple valve wiring is Flat ribbon cable manifold specifications
simplified through the
Model Type 20P Type 41P Type 43P
use of the flat ribbon Manifold type Single base / B mount
cable connector. P(SUP) / R(EXH) Common SUP / Common EXH
Valve stations 3 to 12 stations
• Clean appearance A, B port piping Location Valve Base
In the case of a flat ribbon cable type, each specifications Direction Top Side
valve is wired on the print board of manifold P, R port 1/8 1/8
base to allow the external wiring to be piped Port size M5 x 0.8
all together with 26 pins MIL connector. A, B port C4 (One-touch fitting for ø4) M5 x 0.8 C4 (One-touch fitting for ø4)
C6 (One-touch fitting for ø6)
Applicable flat ribbon
Socket: 26 pins MIL type with strain relief (Conforming to MIL-C-83503)
cable connector
Internal wiring In common between +COM and –COM (Z type: +COM only)
Rated voltage 12, 24 VDC 100, 110 VAC
Note) The withstand voltage specification for the wiring section conforms to JIS C0704, Grade 1 or its
equivalent.

Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
10-SS5YJ5-20P 10-SYJ5첸23 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
for internal pilot
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
Base mounted 10-SS5YJ5-41P 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
10-SYJ5첸43
for internal pilot 10-SS5YJ5-43P 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifolds (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model number.
Example
10-SS5YJ5-41P-07-C4 ······ 1 set (Manifold base)
∗ 10-SYJ5143-5LOU ············ 3 sets (Valve)
∗ 10-SYJ5243-5LOU ············ 3 sets (Valve)
∗ SYJ5000-21-3A ················· 1 set (Blanking plate assembly)
∗ SY3000-37-28A ················· 3 sets (Connector assembly)
∗ SY3000-37-29A ················· 3 sets (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

∗ Use manifold specification sheet.

How to Order Valves How to Order Connector Assembly


Rated voltage Light/surge voltage suppressor 12, 24 VDC
Z With light/surge voltage suppressor Single solenoid SY3000-37-28A
5 24 VDC
Clean series U With light/surge voltage suppressor (Non-polar type) Double solenoid 3 position type SY3000-37-29A
6 12 VDC
Note) Z: Positive common specifications only. For single solenoid, individual SUP/EXH spacer SY3000-37-3A
For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-4A
2
For DC 10 SYJ5 1 4 3 5 LO Z For 3 port adaptor plate
For 100 VAC
SY3000-37-3A

For single solenoid SY3000-37-46A


2
For AC 10 SYJ5 1 4 3 1 LOZ Double solenoid 3 position type SY3000-37-47A
For single solenoid, individual SUP/EXH spacer SY3000-37-32A
Type of actuation For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-33A
1 2 position single 3 port adaptor plate SY3000-37-32A
2 2 position double A, B port size For 100 VAC (115 VAC)
3 3 position closed center Symbol Port size For single solenoid SY3000-37-54A
4 3 position exhaust center Nil Base mounted Double solenoid 3 position type SY3000-37-55A
5 3 position pressure center Rated voltage M5 M5 x 0.8 For single solenoid, individual SUP/EXH spacer SY3000-37-35A
C4 One-touch fitting for ø4 For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-36A
1 100 VAC
C6 One-touch fitting for ø6 For 3 port adaptor plate SY3000-37-35A
3 110 VAC(115 VAC)
N3 One-touch fitting for ø5/32"
Manual override N7 One-touch fitting for ø1/4"
Nil Non-locking push type Note) In the case of flat ribbon cable type, "U" and "Z"
D Push-turn locking slotted type types are for DC specifications and "Z" type is for
AC specifications. "Z" type for DC is positive
E Push-turn locking lever type
common specifications only. For other
combinations, please contact SMC.

526
Manifold specifications 10-SYJ5000

Common SUP / Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20 (5 port / Body ported) How to Order Applicable solenoid valve


M5
10-SYJ5첸23-첸첸첸첸- C4
A, B port 10 SS5YJ5 20 05 C6

Air cylinder
M5 x 0.8 Applicable blanking
Clean series plate assembly
-+ P, R port
-+
P port Number of stations thread type SYJ5000-21-4A
1/8 02 2 stations Applicable individual

R
Nil Rc
P
R
: : 00F G EXH spacer assembly
R port 20 20 stations 00N NPT SYJ5000-17-1A

Rotary actuator
1/8 00T NPTF

Type 40 (5 port / Base mounted) How to Order Applicable solenoid valve


10-SYJ5첸43-첸첸첸첸
10 SS5YJ5 40 05 M5 10-SYJ5첸53-첸첸첸첸
P port
Clean series Applicable blanking
1/8
P, R port plate assembly
Number of stations thread type SYJ5000-21-4A

Air gripper
02 2 stations Nil Rc Applicable individual
: : F G EXH spacer assembly
R port
20 20 stations N NPT SYJ5000-17-1A
A, B port 1/8
T NPTF
M5 x 0.8 A, B port size
M5 M5 x 0.8

Directional control
valve
Type 41 (5 port / base mounted) How to Order
10 SS5YJ5 41 05 M5
Clean series
Number of stations

Flow control
equipment
-+
-+ 02 2 stations P, R port
R port thread type
: :
R

1/8 Nil Rc
P

A, B port 20 20 stations
F G
M5 x 0.8 P port
A, B port size N NPT
1/8
M5 M5 x 0.8 T NPTF

control equipment
Filter, Pressure
Type 42 (5 port / base mounted) How to Order
Applicable solenoid valve
10 SS5YJ5 42 05 C6 10-SYJ5첸43-첸첸첸첸
Clean series 10-SYJ5첸53-첸첸첸첸
Number of stations Applicable blanking
-+ 02 2 stations plate assembly
-+

Fittings & Tubing


B
R port
: : SYJ5000-21-4A
R

20 20 stations Applicable individual


P

1/4
A Thread type
A, B port size EXH spacer assembly
A, B port B Nil Rc
P port
01 1/8
SYJ5000-17-1A
1/8, C6 F G
1/4
C6 One-touch fitting for ø6
Applicable individual
N NPT
SUP spacer assembly
N7 One-touch fitting for ø1/4" T NPTF
SYJ5000-16-2A
Air preparation

Type 43 (5 port / base mounted) How to Order


equipment

10 SS5YJ5 43 05 C4
Clean series
Manifold stations
-+
-+ 02 2 stations
Pressure switch

R port : : P, R port
R

thread type
P

1/8
A, B port A 20 20 stations
B Nil Rc
C4 P port
A, B port size F G
1/8
C4 One-touch fitting for ø4 N NPT
N3 One-touch fitting for ø5/32" T NPTF
Clean gas filter

527
Manifold specifications 10-SYJ5000
Flat ribbon cable manifold
Common SUP / Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 20P (5 port / body ported) How to Order Applicable solenoid valve
Refer to page 526.
A, B port
10 SS5YJ5 20P-- 05
Applicable blanking
P port Clean series P, R port plate assembly
1/8 thread type SYJ5000-21-3A
Number of stations
Nil Rc
03 3 stations
00F G Applicable connector
: : assembly
R port 00N NPT
1/8 12 12 stations 00T NPTF Refer to page 526.

Type 41P (5 port / base mounted) How to Order


10 SS5YJ5 41P 05 M5
A, B port Clean series P, R port size
M5 x 0.8 Applicable solenoid valve
Number of stations Nil Rc Refer to page 526.
P port
03 3 stations F G
1/8
: : N NPT
R port 12 12 stations T NPTF Applicable blanking
1/8 plate assembly
Type 43P (5 port / base mounted) How to Order SYJ5000-21-3A

10 SS5YJ5 43P 05 C4 Applicable connector


A, B port assembly
C4
Clean series P, R port Refer to page 526.
Number of stations thread type
P port 03 3 stations A, B port size Nil Rc
1/8
: : C4 One-touch fitting for ø4 F G
R port 12 12 stations N3 One-touch fitting for ø5/32" N NPT
1/8 T NPTF

<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base
Round head combination screw Round head combination screw
M2.5 x 25 M2.5 x 25
Matt nickel plated Matt nickel plated
(With spring washer) (With spring washer)

Manifold gasket Manifold gasket


DXT192-10-14 DXT192-10-16

Blanking plate assembly


SYJ5000-21-4A SYJ5000-21-3A
Round head combination screw Round head combination screw

Blanking plate
Blanking plate

Gasket Gasket
Caution
Applicable base Mounting screw tightening torque
· 10-SS5YJ5-20
M2.5: 0.45N·m
· 10-SS5YJ5-40 Dust cap Applicable base
· 10-SS5YJ5-41 · 10-SS5YJ5-20P Use caution to the assembly
· 10-SS5YJ5-42 orientation for solenoid valve,
· 10-SS5YJ5-41P
· 10-SS5YJ5-43
gasket, and optional parts.
· 10-SS5YJ5-43P

528
Manifold specifications 10-SYJ5000

<Manifold option>
Mix installation of the 10-SYJ500 and the 10-SYJ5000 valves on the same manifold
앬 Use of an adapter plate makes it possible to mount Series 10-SYJ500 on the manifold bases of series 10-SYJ5000.

Air cylinder
앬 When mounting the 10-SYJ500 valve on the 10-SYJ5000 manifold, the 10-SYJ500 solenoid must be positioned on the same side of the manifold as a single solenoid of 10-SYJ5000.
앬 For base mounted style, the A port of the 3 port valve flows out the B port of manifold base.

Adaptor plate assembly


SYJ500-3-2A SYJ500-3-1A

Rotary actuator
Round head combination screw

Gasket

Air gripper
Round head combination screw
Round head combination screw

Adaptor plate
7

Adaptor plate
7
Adaptor gasket

Directional control
valve
Adaptor gasket Applicable base
· 10-SS5YJ5-40
Applicable base · 10-SS5YJ5-41
· 10-SS5YJ5-20 · 10-SS5YJ5-42
· 10-SS5YJ5-43

Individual EXH spacer assembly Individual SUP spacer assembly

Flow control
equipment
SYJ5000-17-1A
SYJ5000-16-2 A
Round head combination screw Round head combination screw
Thread type
Nil Rc

control equipment
Filter, Pressure
F G
N NPT
T NPTF
B

A
A

Manifold gasket
Manifold gasket

Fittings & Tubing


10

15

Individual EXH spacer

Individual SUP spacer


Air preparation
equipment

Applicable base Applicable base


· 10-SS5YJ5-20 · 10-SS5YJ5-41
· 10-SS5YJ5-40 · 10-SS5YJ5-42
· 10-SS5YJ5-41 · 10-SS5YJ5-43
· 10-SS5YJ5-42
· 10-SS5YJ5-43
Caution
Pressure switch

Mounting screw tightening torque


M2.5: 0.45N·m
Use caution to the assembly
orientation for solenoid
valves, gasket, and optional
parts.
Clean gas filter

529
Manifold specifications 10-SYJ5000
Type 20: Top ported / 10-SS5YJ5-20- Station -00첸 ∗ [ ]: AC

Grommet (G)
(Lead wire length)
Approx. 300

(DIN: 14.6)

(Pitch)

10 18.5 (DIN: 0.8)


P = 16 21
13.4

2.5 2.5 12.5


2
103.2[107.6]

16.515.2

(DIN: 46.2)
(DIN: 46.8)

23.5
87.2[91.6]

16.516.5
R

R
A

A
45.6

67.1[69.3]
67.7[69.9]

45

49
P

P
B

B
R

4-ø4.5 1/8
(For mounting) (P, R port)
M5 x 0.8
Manual override L2 9 (A, B port)
L1
Built-in One-touch fitting

(Station n) (Station 1)

(Light/surge voltage suppressor)


48.6[55.6]

-+ -+ -+ -+ -+
33.2

20

(3.2) 52.8

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
Approx. 300

MAX.10

Applicable cable O.D


Pg7
ø3.5 to ø7
(Lead wire length)
Approx. 300 59.7[66.7] M8 x 1
103.4[107.8]
123[127.4]
107[111.4]

87.4[91.8]

141.2

121.2

106.4
143
125.2

105.2
67.2[69.4]

90.4
127
77[79.2]

68.7
76.1
86.1

87
0.6

0.6

35.6
0.6
0.6

33.2
53.1
0.6
0.6

48.6[55.6] 62.6
73.9
81.4

∗ Refer to page 563 for dimensions with connector cable.


Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330 346
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328

530
Manifold specifications 10-SYJ5000
Type 40: Bottom ported / 10-SS5YJ5-40- Stations -M5첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300

Air cylinder
L1
L2 9

4-ø4.5
(For mounting)

Rotary actuator
13
8.5
(DIN: 23.3) (DIN: 38.1)

(DIN: 22.7) (DIN: 22.7)


103.2[107.6]

16.5

43.6[45.8] 23.5
22.1 36.9

21.5 21.5
R

A A A A A

87.2[91.6]

33
47
P

P
44.2[46.4]

B B B B B
R

2.5

Air gripper
1/8
(Pitch) (P, R port)
P = 16 21 Manual override

(Station n) (Station 1)

(Light/surge voltage suppressor) Built-in speed controller


48.6[55.6]

Directional control
-+ -+ -+ -+ -+
33.2

valve
20

M5 x 0.8
(A, B port)

Flow control
equipment
12
24

MAX.13.5 43.5

control equipment
(Pitch)

Filter, Pressure
P = 16 23

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
Approx. 300

MAX.10

Fittings & Tubing


Applicable cable O.D
Pg7 ø3.5 to ø7
(Lead wire length)
Approx. 300 59.7[66.7] M8 x 1
Air preparation
103.4[107.8]

equipment
123[127.4]
107[111.4]

87.4[91.8]

141.2

121.2

106.4
143
125.2

105.2

90.4
127
43.7[45.9]
53.5[55.7]

45.2
52.6
62.6

63.5

Pressure switch
0.6

0.6

35.6
0.6
0.6

33.2
53.1
0.6

62.6
0.6

48.6[55.6]
73.9
81.4
Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330 346
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328

531
Manifold specifications 10-SYJ5000
Type 41: Side ported / 10-SS5YJ5-41- Stations -M5첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300

L1
4.5 L2 Manual override

2-ø5.5
(For mounting)

12
60.2[62.4]

59.6[61.8]
(DIN: 38.7)
(DIN: 22.1) (DIN: 39.3)

87.2[91.6]
103.2[107.6]

R
B B B B B
38.1

21
35
5.5 37.5
3.5 17.5
P

A A A A A

7
20.9

(DIN: 6.7) 1/8


(P, R port)

(Pitch)
18 P = 16

Built-in speed controller


(Station 1) (Station n)
MAX.13.5 47.5

(Light/surge voltage suppressor)


52.6[59.6]

-+ -+ -+
37.2

A A
18.5
24

B B
5.5

(Pitch)
23 P = 16
M5 x 0.8
(A, B port)

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)

85.4
77.9
52.6[59.6] 66.6
0.6

M8 x 1
0.6

57.1
37.2
0.6

39.6
0.6
0.6

0.6
69.5[71.7]

59.7[61.9]

79.5
78.6

68.6

61.2
107[111.4]

87.4[91.8]
103.4[107.8]
123[127.4]

125.2

105.2
127

90.4
141.2

121.2

106.4
143
3.5
3.5

3.5
3.5

Approx. 300 63.7[70.7]


(Lead wire length)

Pg7
MAX.10
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340
L2 43 59 75 91 107 123 139 155 171 187 203 219 235 251 267 283 299 315 331

532
Manifold specifications 10-SYJ5000
Type 42: Side ported / 10-SS5YJ5-42- Stations -01, C6
N7 첸 ∗ [ ]: AC

Grommet (G) C6
01첸 N7 첸(With built-in One-touch fitting)

Air cylinder
(Lead wire length)
Approx. 300

L1 Manual override
6.5 L2
2-ø6.5

Rotary actuator
(For mounting)

17.5 17.5
65.2[67.4]

64.6[66.8]
(DIN: 43.7)
(DIN: 44.3)

87.2[91.6]
103.2[107.6]

B B B B B

43.9
24

24
44
0.5 42.5
43.1

23
P

A A A A A

10.4
(DIN: 1.7)

10.5

Air gripper
15.9
(DIN: 17.1)

1/4 1/4
(Pitch) (P, R port)
24.5 P = 17 (P, R port)

(Station 1) (Station n)

Directional control
(Station 1) (Station n)
(Light/surge voltage suppressor) Built-in speed controller (Light/surge voltage suppressor)

valve
MAX.13.5 56.5

61.6[68.6]
61.6[68.6]

-+ -+ -+ -+ -+ -+

46.2
46.2

A A A A
33

33
24.5

25
B B B B

6 1
8.5

8.5

Flow control
equipment
(Pitch) (Pitch)
24.5 P = 17 1/8 29 P = 16 One-touch fitting
(A, B port) (A, B port)
Applicable tubing
O.D.: ø6,ø1/4"

control equipment
Filter, Pressure
∗ Other dimensions are the same as the grommet type.

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)

94.4

Fittings & Tubing


61.6[68.6] 86.9
M8 x 1 66.1
0.6
0.6

75.6
46.2
0.6

0.6

48.6 0.6
0.6
74.5[76.7]

64.7[66.9]

84.5
83.6

73.6
107[111.4]

87.4[91.8]
103.4[107.8]

66.2
123[127.4]

125.2

105.2

90.4
127
141.2

121.2

106.4
143

Air preparation
equipment

Approx. 300 72.7[79.7]


(Lead wire length)
(Lead wire length)

MAX.10

Pg7
Pressure switch

Applicable cable O.D


Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.


Clean gas filter

A, B port size Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 66 83 100 117 134 151 168 185 202 219 236 253 270 287 304 321 338 355 372
1/8
L2 53 70 87 104 121 138 155 172 189 206 223 240 257 274 291 308 325 342 359
L1 65 81 97 113 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353
C6/N7
L2 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340

533
Manifold specifications 10-SYJ5000
C4
Type 43: Side ported / 10-SS5YJ5-43- Stations - N3 첸 ∗ [ ]: AC

Grommet (G)
(Lead wire length)
Approx. 300

L1
4.5 L2 Manual override

2-ø5.5
(For mounting)
12 1/8
(P, R port)
62.6[64.8]

62[64.2]
(DIN: 4.3) (DIN: 41.1)
(DIN: 41.7)

87.2[91.6]
103.2[107.6]

R
B B B B B
40.5

17.5
36.9
3.1 39.9
1.1 20.2
P

P
A A A A A

11.4
(4.4)
18.5
(DIN: 19.7)

(Pitch)
18 P = 16

Built-in speed controller


(Station 1) (Station n)
MAX.13.5 47.5
(Light/surge voltage suppressor)
52.6[59.6]

-+ -+ -+
37.2

A A
24
18

B B
6

(Pitch)
22.3 P = 16 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4,ø5/32"

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
85.4
52.6[59.6] 77.9
66.6 M8 x 1 57.1
0.6
0.6

37.2
39.6
0.6

0.6

0.6
0.6
72[74.2]

62.2[64.4]

81.1

82

63.7
71.1
125.2

90.4
127
107[111.4]

141.2

106.4
87.4[91.8]

105.2
143
123[127.4]

103.4[107.8]

121.2
1

Approx. 300 63.7[70.7]


(Lead wire length)
(Lead wire length)

Pg7
MAX.10

Applicable cable O.D


Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340
L2 43 59 75 91 107 123 139 155 171 187 203 219 235 251 267 283 299 315 331

534
Manifold specifications 10-SYJ5000

Flat ribbon cable manifold ∗ [ ]: AC

10-SS5YJ5-20P- Stations -00첸

Air cylinder
C4, N3
Manual override C6, N7
L1
M5 x 0.8 L2 9 (With built-in One-touch fitting)

Rotary actuator
(A, B port) 4-ø4.5
-+

(For mounting)
13.4

-+ -+

2.5 2.5 12.5

15.2
2
123[127.4]

107[111.4]
10 18.5

23.5
R

R One-touch fitting

16.5 16.5
A

A
45.6

(A, B port)
77.6 [79.8]

45

49
77 [79.2]
P

Applicable tubing

65
82.8
16.5
B

O.D.: ø4, ø5/32"

Air gripper
R

ø6, ø1/4"

-+ -+ -+ -+ -+

Triangle mark
1/8 (3.2) 52.8
(Pitch)
P = 17.5 21 (P, R port)

Directional control
(Station n) (Station 1)
(Light/surge voltage suppressor)

valve
48.6[55.6]

5.8
25.1
20

Applicable connector: 28.5

Flow control
26 pins MIL type with strain relief Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations

equipment
(Conforming to MIL-C-83503) L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 59 76.5 94 111.5 129 146.5 164 181.5 199 216.5

10-SS5YJ5-41P- Stations -M5첸


(Pitch)

control equipment
M5 x 0.8

Filter, Pressure
5.5

P = 17.5 26
(A, B port)
18.5

Built-in speed controller

Fittings & Tubing


L1
Manual override L2 7.5
-+

-+ -+
5.5
3.5
38.1 20.9

12
123[127.4]

7
107[111.4]
17.5

A A A A A
Air preparation

5.5
37.5

equipment
69.5 [71.7]
70.1 [72.3]

21
35
51

MAX.13.5
68.8

B B B B B

-+ -+ -+ -+ -+

2-ø5.5 Triangle mark 1/8


(For mounting) (Pitch) (P, R port)
Pressure switch

P = 17.5 21

(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6[59.6]

7.8
29.1

Clean gas filter


24

Applicable connector: 28.5


26 pins MIL type with strain relief Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations
(Conforming to MIL-C-83503) L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 62 79.5 97 114.5 132 149.5 167 184.5 202 219.5

535
Manifold specifications 10-SYJ5000

Flat ribbon cable manifold ∗ [ ]: AC

C4
10-SS5YJ5-43P- Stations - N3 첸
One-touch fitting (Pitch)
(A, B port) P = 17.5 25.3

6
Applicable tubing
O.D.: ø4, ø5/32"

18
L1 Built-in speed controller
Manual override L2 7.5
-+

-+ -+

(4.4)
11.4
12
3.1
1.1
40.5 18.5
123 [127.4]

107 [111.4]
20.2

A A A A A

5.5

36.9
39.9

17.5
71.9 [74.1]
72.5 [74.7]

52.9

MAX.13.5

70.7
B B B B B

-+ -+ -+ -+ -+

4-ø5.5 Triangle mark 1/8


(For mounting) (Pitch) (P, R port)
P = 17.5 21

(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6 [59.6]

7.8
29.1
24

Applicable connector: 28.5


26 pins MIL type with strain relief
(Conforming to MIL-C-83503)

Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations


L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 62 79.5 97 114.5 132 149.5 167 184.5 202 219.5

536
Series10-SYJ7000
Rubber seal
5 port solenoid valve

Air cylinder
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure
2 position double 0.1 to 0.7
range (MPa)
3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (with no freezing. Refer to page 714.)

Rotary actuator
Response time ms 2 position single, double 30 or less
(0.5MPa) Note 1) 3 position 60 or less
Max. operating 2 position single, double 5
frequency (Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the pilot and main valve
Body ported Lubrication Not required
Mounting orientation Unrestricted

Air gripper
Impact/Vibration resistance m/s2 Note 2) 150/30
Enclosure Dustproof (∗DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature : 20°C, at rated voltage,
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction

Directional control
and at the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep between 45 and 2000Hz. Test was

valve
performed in the axial direction and at the right angles to the main valve and armature in both
energized and de-energized states every once for each condition. (Value in the initial state)

Base mounted
Solenoid specifications

Flow control
equipment
JIS Symbol
Body ported Base mounted Grommet (G), (H)
2 position single 2 position single solenoid
L plug connector (L)
M plug connector (M)
(A)(B) (B)(A) Electrical entry
4 2 2 4 DIN terminal (D)
M8 connector (W)

control equipment
Filter, Pressure
5 1 3 3 1 5 G, H, L, M, W D
(R1) (P) (R2) (R2) (P) (R1)
DC 24, 12, 6, 5, 3 24, 12
Coil rated voltage V
2 position double 2 position double solenoid AC 50/60Hz 100, 110, 200, 220
(A)(B) (B)(A) Allowable voltage fluctuation ±10% of rated voltage ∗
4 2 2 4
Standard 0.35 {With indicator light: 0.4 (DIN connector with indicator light: 0.45)}
Power consumption (W) DC
With power saving circuit 0.1 (With indicator light only)
5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1) 100V 0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)

Fittings & Tubing


110V 0.86 (With indicator light: 0.89) 0.86 (With indicator light: 0.97)
3 position closed center 3 position closed center
∗ [115V] [0.94 (With indicator light: 0.97)] [0.94 (With indicator light: 1.07)]
(A)(B) (B)(A) Apparent power (VA) AC
4 2 2 4 200V 1.18 (With indicator light: 1.22) 1.15 (With indicator light: 1.30)
220V 1.30 (With indicator light: 1.34) 1.27 (With indicator light: 1.46)
5 1 3 3 1 5 [230V] [1.42 (With indicator light: 1.46)] [1.39 (With indicator light: 1.60)]
(R1) (P) (R2) (R2) (P) (R1) Surge voltage suppressor Diode (DIN terminal, varistor for non-polar type)
3 position exhaust center 3 position exhaust center Indicator light LED (Neon light when AC with DIN terminal)
(A)(B) (B)(A) ∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
Air preparation

4 2 2 4
equipment

∗ For 115 and 230 VAC, the allowable voltage fluctuation is -15% to +5% of rated voltage.
∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please observe the
5 1 3 3 1 5 following range because they have voltage drop due to internal circuit.
(R1) (P) (R2) (R2) (P) (R1) S and Z types 24 VDC: –7% to +10%
12 VDC: –4% to +10%
3 position pressure center 3 position pressure center T type 24 VDC: –8% to +10%
(A)(B) (B)(A) 12 VDC: –6% to +10%
4 2 2 4
Pressure switch

5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1)

Made to
Order Made to order specifications (Refer to page 557 for details.)
Clean gas filter

537
5 port solenoid valve Series 10-SYJ7000

Flow characteristics / Weight


Port size Flow characteristicsNote 1) Weight (g)Note 2, 3)
Valve model Type of actuation 1,5,3 4,2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB) L/M plug DIN M8
Grommet
(P,EA,EB) (A,B) C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv connector terminal connector
Single 85 86 107 90
2 position 2.2 0.36 0.58 2.4 0.34 0.63
Double 98 100 142 108
10-SYJ7첸23-첸-01 Closed center 1/8 1/8 1.8 0.37 0.45 2.0 0.35 0.49
3 position Exhaust center 1.2 0.50 0.34 3.0[1.3] 0.35[0.52] 0.73[0.39] 108 110 152 118
Pressure center 3.0[0.83] 0.37[0.50] 0.78[0.25] 1.8 0.37 0.45
Single 96 97 98 101
Body ported

2 position 1.6 0.33 0.4 2.2 0.32 0.53


Double C6 109 111 153 119
10-SYJ7첸23-첸-C6 Closed center 1/8 (One-touch 1.4 0.27 0.35 1.9 0.33 0.49
3 position Exhaust center fitting for ø6) 1.1 0.37 0.27 2.5[1.3] 0.32[0.54] 0.61[0.38] 119 121 163 129
Pressure center 1.8[0.78] 0.36[0.40] 0.45[0.22] 1.6 0.30 0.39
Single 96 97 98 101
2 position 2.0 0.39 0.52 2.3 0.34 0.61
Double C8 109 111 153 119
10-SYJ7첸23-첸-C8 Closed center 1/8 (One-touch 1.7 0.35 0.42 2.0 0.29 0.49
3 position Exhaust center fitting for ø8) 1.2 0.38 0.33 2.6[1.3] 0.35[0.49] 0.67[0.38] 119 121 163 129
Pressure center 1.9[0.86] 0.57[0.46] 0.59[0.25] 1.7 0.39 0.42
Single 165(85) 166(86) 187(107) 170(90)
2 position 2.3 0.45 0.57 2.8 0.37 0.71
Double 178(98) 180(100) 222(142) 188(108)
10-SYJ7첸43-첸-01 Closed center 1/8 1/8 1.9 0.36 0.48 2.1 0.46 0.57
Base mounted

3 position Exhaust center 1.2 0.48 0.35 3.4[1.3] 0.36[0.57] 0.86[0.41] 188(108) 190(110) 232(152) 198(118)
Pressure center 3.3[0.85] 0.43[0.54] 0.78[0.25] 2.1 0.45 0.56
Single 165(85) 166(86) 187(107) 170(90)
2 position 2.3 0.41 0.61 2.9 0.35 0.74
Double 178(98) 180(100) 222(142) 188(108)
10-SYJ7첸43-첸-02 Closed center 1/4 1/4 1.9 0.46 0.50 2.2 0.44 0.60
3 position Exhaust center 1.3 0.45 0.35 3.7[1.4] 0.27[0.56] 0.87[0.43] 188(108) 190(110) 232(152) 198(118)
Pressure center 3.6[0.83] 0.23[0.55] 0.84[0.25] 2.1 0.47 0.58
Note 1) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate
Note 3) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types.

538
5 port solenoid valve Series 10-SYJ7000

How to Order
Light/Surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Type of actuation

Air cylinder
Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
1 2 position single solenoid S With surge voltage suppresser S With surge voltage suppresser (Non-polar type)
2 2 position double solenoid Z With light/surge voltage suppresser Z With light/surge voltage suppresser (Non-polar type)
3 3 position closed center R With surge voltage suppressor (Non-polar type) ∗ "DOZ" is not available.
∗ For AC voltage valves, there is
Bracket
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
no "S" option. It is already built-
5 3 position pressure center ∗ For AC voltage valves, there is no "S" option. It is Nil: Without bracket
in to the rectifier circuit.
already built-in to the rectifier circuit. F: With bracket

Rotary actuator
∗ For "R" and "U", DC voltage is only available.
∗ Power saving circuit is only available in the "Z" Thread type
type.
Nil Rc
F G
Rated voltage
N NPT
DC specifications AC specifications (50/60Hz)
T NPTF
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC [115 VAC] 01 1/8

Air gripper
Note) Do not remove the factory
S 5 VDC 4 220 VAC [230 VAC] C6 One-touch fitting for ø6 installed bracket from
R 3 VDC ∗ For type "W첸", C8 One-touch fitting for ø8 models with the bracket
∗ DC specifications of option. Removal of the
DC voltage is N7 One-touch fitting for ø1/4" bracket will cause the
type "D" and "DO" is only available.
only available with N9 One-touch fitting for ø5/16" valve to leak. Brackets
(For manifold type 20, 21) 12 and 24 V DC. cannot be retrofitted.

Directional control
Body ported 10 SYJ7 1 23 5 M 01

valve
Base mounted 10 SYJ7 2 43 5 M

Flow control
Thread type

equipment
Nil Rc
Coil specifications Manual override F G
Nil Standard N NPT
Nil: Non-locking push
With power saving circuit type T NPTF
T
<For 24 and 12 VDC only>

control equipment
∗ Power saving circuit is

Filter, Pressure
Sub-plate, 40, 41, 42
not available in the
manifold Port size
case of "D", "DO" or
"W첸" type. Nil: Without sub-plate

D: Push-turn locking
slotted type

Fittings & Tubing


Electrical entry (With gasket and screws)

24, 12 VDC, 24, 12 VDC, 01: 1/8 with sub-plate Note)


24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC
100, 110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector DIN terminal M8 connector
E: Push-turn locking
Air preparation

G: Lead wire L: With lead M: With lead wire MN: Without D: With connector WO: Without
equipment

length wire (length (length 300 mm) lead wire connector lever type
300 mm 300 mm)
+- +-

-+ 02: 1/4 with sub-plate


-+

Pressure switch

H: Lead wire LN: Without LO: Without MO: Without DO: Without W첸: With connector
length 600 mm lead wire connector connector connector cable Note 1)

Note 1) Be sure to enter a


symbol of the
-+
-+

cable length with Note) R1, R2 ports :


Clean gas filter

reference to page 1/4


562.
∗ "LN", "MN" type : with 2 sockets.
∗ DIN terminal type "Y" conforming to EN-175301-803C (former DIN43650C) is also available. For
details, refer to page 557.
∗ For connector cable of M8 connector, refer to page 562.

539
5 port solenoid valve Series 10-SYJ7000

How to Order Pilot Valve Assembly

10 V111 5 G 10 V115 5 D
Clean series Clean series
Light/Surge voltage suppressor
Coil specifications Without light/surge voltage suppressor
Rated voltage
Nil
Nil Standard 5 24 VDC
S With surge voltage suppressor
With power saving circuit 6 12 VDC
T Z With light/surge voltage suppressor Light/surge voltage suppressor
<24 and 12 VDC only> 1 100 VAC 50/60Hz
R With surge voltage suppressor (Non-polar type) 2 200 VAC 50/60Hz Nil Without light/surge voltage suppressor
∗ Power saving circuit is U With light/surge voltage suppressor (Non-polar type) 110 VAC 50/60Hz S With surge voltage suppressor (Non-polar type)
not available in the 3
∗ For AC voltage valves, there is no [115 VAC 50/60Hz] Z With light/surge voltage suppressor (Non-polar type)
case of "W첸" type.
"S" option. It is already built-in to 4 220 VAC 50/60Hz ∗ "DOZ" is not available.
the rectifier circuit. [230 VAC 50/60Hz] ∗ For AC voltage valves, there
Rated voltage ∗ For "R" and "U", DC voltage is only is no "S" option. It is already
5 24 VDC available. built-in to the rectifier circuit.
∗ Power saving circuit is only available
6 12 VDC
in the "Z" type.
V 6 VDC
S 5 VDC
R 3 VDC Electrical entry Electrical entry
1 100 VAC 50/60Hz G Grommet (Lead wire length 300 mm) D With connector
DIN
2 200 VAC 50/60Hz H Grommet (Lead wire length 600 mm) DO terminal Without connector
110 VAC 50/60Hz L With lead wire
3 Note) Do not replace 10-V111
[115 VAC 50/60Hz] L plug
LN
connector Without lead wire (G, H, L, M, W) to 10-
220 VAC 50/60Hz LO Without connector V115 (DIN terminal) and
4
[230 VAC 50/60Hz] M With lead wire vice versa when
∗ For type "W첸", DC M plug replacing pilot valve
MN
voltage is only connector Without lead wire Note 1) Be sure to enter a assembly only.
MO Without connector symbol of the cable
available.
WO M8 Without connector cable length with reference
W첸 connector With connector cable Note 1) to page 562.
∗ For connector cable of M8
connector, refer to page 562.

How to Order L/M Plug Connector Assembly How to Order M8 Connector Cable

For DC :SY100-30-4A-
V100-49-1-
For 100 VAC :SY100-30-1A-
For 200 VAC :SY100-30-2A- Cable length
1 300mm
For other voltages of AC :SY100-30-3A- 2 500mm
3 1000mm
Without lead wire 4 2000mm
(With connector and 2 of sockets only) :SY100-30-A 7 5000mm

Lead wire length


Nil 300mm
6 600mm
10 1000mm
15 1500mm
20 2000mm
25 2500mm
30 3000mm
50 5000mm

540
5 port solenoid valve Series 10-SYJ7000

2 position single ∗ [ ]: AC

Grommet (G), (H): 10- SYJ7123-첸GH 첸첸-01첸 With bracket


10-SYJ7123-첸GH 첸첸-01첸-F

Air cylinder
44
2-ø4.5 36 4
(For mounting)

26
34
- +
G: Approx. 300
82[84.2] H: Approx. 600

Rotary actuator
59.8 (Lead wire length) 24.1
28.3 39.5[46.5]
13
3

A B

Manual override
2-ø3.2 17
(For manifold mounting) 1/8

85.6[87.8]
35 (A, B port)

Air gripper
2-ø3.2 (Light/surge voltage suppressor)
35
(For mounting) (Bracket)

3.6
-+
28
25

16.1
21

Directional control
31.5[38.5]

valve
Built-in One-touch fitting:
10-SYJ7123-첸GH 첸첸- C6, N7
C8, N9 첸 (-F)
R1 P R2
28.3
1.6
18

1/8 27.2 A B
(P, R1, R2 port)

Flow control
equipment
17
One-touch fitting
(4.9)

(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
: ø8, ø5/16"

control equipment
36

Filter, Pressure
(3.6)

L plug connector (L) M plug connector (M) DIN Terminal (D): M8 connector (WO):

Fittings & Tubing


10-SYJ7123-첸L첸첸-01첸 (-F) 10-SYJ7123-첸M첸첸-01첸 (-F) 10-SYJ7123-첸D첸첸-01첸 (-F) 10-SYJ7123-첸WO첸첸-01첸 (-F)
Applicable cable O.D.
Approx. 300 (Lead wire length)

ø3.5 to ø7
65
31.5[38.5]
MAX.10

57.5
16.1 46.2
31.1 M8 x 1 36
Air preparation
equipment

(Lead wire length) 18.5


Approx. 300 42.6[49.6]

Pg7
91.9[94.1]

101.9
82.1[84.3]

101

Pressure switch
91
83.6
77.1

61.1
35

35

35

35
28.3

28.3

28.3

28.3

21 21 21 21
(3.6)

(3.6)

(3.6)

(3.6)

2-ø3.2 2-ø3.2 2-ø3.2 2-ø3.2


25 25 25 25
Clean gas filter

(For mounting) (For mounting) (For mounting) (For mounting)


28 28 28 28

∗ Refer to page 563 for dimensions with connector cable.

541
5 port solenoid valve Series 10-SYJ7000

2 position double ∗ [ ]: AC

Grommet (G), (H): 10-SYJ7223-첸GH 첸첸-01첸 Built-in One-touch fitting:


10-SYJ7223-첸GH 첸첸- C6, N7
C8, N9 첸

G: Approx. 300
107.4[111.8] H: Approx. 600
63 (Lead wire length)
3
13

A B A B

Manual override
17 17
2-ø3.2 35 1/8 (A, B port)
(For manifold mounting)
One-touch fitting

(4.9)
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"

36
-+
28
25

16.1
21

31.5[38.5]
1.6

R1 P R2
18

1/8 (P, R1, R2 port) 27.2

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7223-씲L씲씲-01씲 10-SYJ7223-씲M씲씲-01씲 10-SYJ7223-씲D씲씲-01씲 10-SYJ7223-씲WO씲씲-01씲
(Lead wire length)
Approx. 300

65
31.5[38.5]
MAX.10

57.5
16.1 46.2
31.1 M8 x 1 36
Approx. 300 42.6[49.6] 18.5
(Lead wire length)

2-ø3.2
(For mounting) 2-ø3.2
127.2[131.6]

2-ø3.2 (For mounting) 2-ø3.2


107.6[112]

(For mounting) (For mounting)


145.4

147.2

125.4
110.6
97.6

65.6
35

35

35

35

21
21
21 25
21 25
28 Pg7
25 25 28
Applicable cable O.D.
28 28
ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

542
5 port solenoid valve Series 10-SYJ7000

3 position closed center / Exhaust center / Pressure center ∗ [ ]: AC


3
Grommet (G), (H): 10-SYJ7 45 23-첸 GH 첸첸-01첸 Built-in One-touch fitting:
3
10-SYJ7 45 23-첸GH 첸첸- C6, N7
C8, N9 첸

Air cylinder
G: Approx. 300
122[126.4] H: Approx. 600
(Lead wire length)

Rotary actuator
54.5[56.7]
45.3 32.3
3
13

A B A B

Manual override
17 17
2-ø3.2 1/8 (A, B port)
(For manifold mounting) 35
One-touch fitting

(4.9)

Air gripper
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"

36
- +
28
25

16.1
21

Directional control
31.5[38.5]

valve
1.6

R1 P R2
18

1/8 (P, R1, R2 port) 27.2

Flow control
equipment
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3 3
10-SYJ7 45 23-첸L첸첸-01첸 10-SYJ7 45 23-첸M첸첸-01첸 10-SYJ7 45 23-첸D첸첸-01첸 10-SYJ7 45 23-첸WO첸첸-01첸
(Lead wire length)
Approx. 300

65
31.5[38.5]
MAX.10

57.5
16.1

Fittings & Tubing


46.2
31.1 M8 x 1 36
Approx. 300 42.6[49.6] 18.5
(Lead wire length)
64.4[66.6]

74.4
54.6[56.8]

73.5

63.5
56.1
49.6

Air preparation
33.6

equipment
141.8[146.2]

122.2[126.6]
35

35

35

35
161.8
160

140
46.6
62.6

2-ø3.2 21 2-ø3.2 21 2-ø3.2 21 2-ø3.2 21


69.1

(For mounting) 25 (For mounting) 25 (For mounting) 25 (For mounting) 25


Pressure switch

28
28
28
Pg7 28
Clean gas filter

Applicable cable O.D.


ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

543
5 port solenoid valve Series 10-SYJ7000

2 position single ∗ [ ]: AC

Grommet (G), (H): 10- SYJ7143-첸 GH 첸첸- 01


02 첸

22

12
34 8.5
2-ø4.3
Manual override B A (For mounting)

27
A
B
R2 P R1

G: Approx. 300 59.8 3.2


H: Approx. 600 85.2[87.4]
(Lead wire length)

(Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port)


57.5[64.5]

- +

54
42.1
25.5

20
12
11.5
18 1/4 (R1, R2 port) 22 22
34 31.5
63

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7143-첸L첸첸- 0102 첸 10-SYJ7143-첸M첸첸- 0102 첸 10-SYJ7143-첸D첸첸- 01
02 첸 10-SYJ7143-첸WO첸첸- 01
02첸
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7

91
MAX.10

57.5[64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
44.5
68.6[75.6] Approx. 300

20 20 20 20
Pg7
95.1[97.3]

104.2
85.3[87.5]

94.2
86.8
80.3
22

22

22

22
64.3
63

63

63

63
22

22

22

22
31.5

31.5

31.5

31.5
3.2

3.2
3.2

3.2

11.5 11.5 11.5 11.5


12 12 12 12
25.5 25.5 25.5 25.5

∗ Refer to page 563 for dimensions with connector cable.

544
5 port solenoid valve Series 10-SYJ7000

2 position double ∗ [ ]: AC

Grommet (G), (H): 10-SYJ7243-첸GH 첸첸- 01


02첸

Air cylinder
22

12

Rotary actuator
G: Approx. 300
H: Approx. 600 107.4[111.8]
(Lead wire length) 63

Air gripper
B A

27
A
B
Manual override R2 P R1

2-ø4.3 34 8.5
(For mounting)

Directional control
(Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port)

valve
57.5[64.5]

- +
42.1
25.5

20
12
11.5

22 22

Flow control
18 1/4 (R1, R2 port)

equipment
34 31.5
63

control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7243-첸L첸첸- 0102첸 10-SYJ7243-첸M첸첸- 0102 첸 10-SYJ7243-첸D첸첸- 01
02 첸 10-SYJ7243-첸WO첸첸- 01
02첸

Applicable cable O.D.


(Lead wire length)

Fittings & Tubing


ø3.5 to ø7
Approx. 300

91
57.5[64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
68.6[75.6] Approx. 300 44.5
Air preparation
equipment

20 20 20 20
Pg7
127.2[131.6]

107.6[112]
22

22 22

22
22

147.2

145.4

110.6
125.4
97.6

65.6
63

63

63
63

22

22
22

31.5

31.5

31.5
31.5

Pressure switch

11.5 11.5 11.5 11.5


12
12 12 12
25.5
25.5 25.5 25.5
MAX.10

Clean gas filter

∗ Refer to page 563 for dimensions with connector cable.

545
5 port solenoid valve Series 10-SYJ7000

3 position closed center / Exhaust center / Pressure center ∗ [ ]: AC

3
Grommet (G), (H): 10-SYJ7 45 43-첸 GH첸첸- 01
02 첸

22

12
G: Approx. 300
H: Approx. 600 122[126.4]
(Lead wire length) 2-ø4.3 36[38.2]
(For mounting)
B A

27
A
B
R2 P R1
Manual override 34 8.5
63.8 13.8

(Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port)


57.5[64.5]

- +
42.1
25.5

20
12
11.5

18 1/4 (R1, R2 port) 22 22


34 31.5
63

L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3 3
10-SYJ7 45 43-첸L첸첸- 01
02 첸 10-SYJ7 45 43-첸M첸첸- 01
02 첸 10-SYJ7 45 43-첸D첸첸- 01
02첸 10-SYJ7 45 43-첸WO첸첸- 01
02첸
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Approx. 300

91
57.5[64.5] 83.5
42.1 72.2
Pg7 62 M8 x 1
(Lead wire length) 57.1
68.6[75.6] Approx. 300 44.5

20 20 20 20
141.8[146.2]

87.6
122.2[126.6]
81.1
22

22

22 22

22
65.1
161.8
63

63

63

63
160

140
22

22

22
31.5

31.5

31.5

31.5
15.1
45.9[48.1]

31.1

11.5 11.5 11.5 11.5


37.6
45
55.9

12 12 12 12
55

25.5 25.5 25.5 25.5


36.1[38.3]

MAX.10

∗ Refer to page 563 for dimensions with connector cable.

546
Series 10-SYJ7000 Manifold specifications

Air cylinder
Manifold standard

Manifold specifications

Model Type 20 Type 21 Type 40 Type 41 Type 42

Rotary actuator
Manifold type Single base / B mount
P (SUP) / R (EXH) Common SUP / Common EXH
Valve stations 2 to 15 stations 2 to 20 stations
A, B port porting Location Valve Base Base
specifications Direction Top Bottom Side
P, R port 1/8 1/4

Air gripper
1/8 C6 (One-touch
Port size A, B port C6 (One-touch fitting for ø6) 1/8 fitting for ø6)
C8 (One-touch fitting for ø8) C8 (One-touch
fitting for ø8)

Directional control
Flow characteristics

valve
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 1/8 2.2 0.35 0.57 2.3 0.26 0.55
Body

Flow control
equipment
ported
10-SS5YJ7-20 1/8 C6 1.4 0.32 0.37 2.0 0.25 0.49
for
10-SYJ7첸23 1/8 C8 1.7 0.38 0.45 2.1 0.25 0.51
1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
internal
pilot
10-SS5YJ7-21 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Base 10-SS5YJ7-40 1/4 1/8 2.1 0.28 0.51 2.5 0.23 0.59

control equipment
mounted 10-SS5YJ7-41 10-SYJ7첸43 1/4 1/8 2.0 0.30 0.50 2.2 0.30 0.55

Filter, Pressure
for internal 10-SS5YJ7-42-C6 1/4 C6 1.5 0.32 0.38 2.2 0.23 0.52
pilot 10-SS5YJ7-42-C8 1/4 C8 1.9 0.24 0.46 2.2 0.26 0.53
Note) Value at manifold base mounted, 2 position single operating

Fittings & Tubing


How to Order Manifold
Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with
the manifold base model number.
Example 앬 10-SS5YJ7-20-03 ········ 1 set (Manifold base)
∗ 10-SYJ7123-5G-01 ······· 2 sets (Valve)
∗ SYJ7000-21-1A ············ 1 set (Blanking plate assembly)
Air preparation
equipment

앬 10- SS5YJ7-41-03-01 ·· 1 set (Manifold base)


∗ 10- SYJ7143-5LZ ·········· 1 set (Valve)
∗ 10- SYJ7243-5LZ ·········· 1 set (Valve)
∗ SYJ7000-21-1A ············ 1 set (Blanking plate assembly)

The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the
Pressure switch

solenoid valve, etc.


∗ Use manifold specification sheet.
Clean gas filter

547
Manifold specifications 10-SYJ7000

Flat ribbon cable manifold

• Multiple valve wiring is Flat ribbon cable manifold specifications


simplified through the
Model Type 21P
use of the flat ribbon Manifold type Single base / B mount
cable connector. P(SUP) / R(EXH) Common SUP / Common EXH
Valve stations 3 to 12 stations
• Clean appearance A, B port porting specifications Valve
In the case of a flat ribbon cable type, each valve P, R port 1/4
is wired on the print board of manifold base to
Port size
A, B port 1/8, C6, C8
allow the external wiring to be piped all together
with 26 pins MIL connector. Applicable flat ribbon Socket: 26 pins MIL type with strain relief (Conforming to MIL-C-83503)
cable connector (MIL-C-83503 compliant)
Internal wiring In common between +COM and –COM (Z type: +COM only)
Rated voltage 24, 12 VDC
Note) The value is for manifold base and individually operated 2 position type.
Note 2) The withstand voltage specification for the wiring unit section is JIS C0704, Grade 1 or its equivalent.

Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
Body ported 10-SS5YJ7-21P-01 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
for internal 10-SS5YJ7-21P-C6 10-SYJ7첸23 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
pilot 10-SS5YJ7-21P-C8 1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Note) Value at manifold base mounted, 2 position single operating

How to Order Manifold (Example)


Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model number.
(Example) 앬 10-SS5YJ7-21P-07 ···· 1 set (Manifold base)
∗ 10-SYJ7123-5LOU-C8 ·····3 sets (Valve)
∗ 10-SYJ7223-5LOU-C8 ·····3 sets (Valve)
∗ SYJ7000-21-3A ····· 1 set (Blanking plate assembly)
∗ SY3000-37-3A ······ 3 sets (Connector assembly)
∗ SY3000-37-4A ······ 3 sets (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
∗ Use manifold specification sheet.

How to Order Valve How to Order Connector Assembly


Light/Surge voltage suppressor
Rated voltage Z With light/surge voltage suppressor 12V, 24 VDC
5 24 VDC With light/surge voltage For single solenoid SY3000-37-3A
U
6 12 VDC suppressor (Non-polar type) For double solenoid 3 position type SY3000-37-4A
Note) Z: Positive common specifications only. For single solenoid, individual SUP/EXH spacer SY3000-37-3A
For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-6A
For DC10 SYJ7 1 23 5 LO Z 01 3 port adaptor plate SY3000-37-3A
100 VAC
For single solenoid SY3000-37-32A
For AC10 SYJ7 1 23 1 LOZ 01 For double solenoid 3 position type SY3000-37-33A
For single solenoid, individual SUP/EXH spacer SY3000-37-15A
For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-34A
Type of actuation A, B port size 3 port adaptor plate SY3000-37-32A
1 2 position single Symbol Port size
2 2 position double 01 1/8
100 VAC (115 VAC)
3 3 position closed center C6 One-touch fitting for ø6 For single solenoid SY3000-37-35A
4 3 position exhaust center C8 One-touch fitting for ø8 For double solenoid 3 position type SY3000-37-36A
5 3 position pressure center N7 One-touch fitting for ø1/4" For single solenoid, individual SUP/EXH spacer SY3000-37-19A
N9 One-touch fitting for ø5/16" For double solenoid, 3 position individual SUP/EXH spacer SY3000-37-37A
Rated voltage 3 port adaptor plate SY3000-37-35A
1 100 VAC
3 110 VAC (115 VAC)
Note) In the case of flat ribbon cable
Manual override type, "U" and "Z" types are for DC
specifications and "Z" type is for
Nil Non-locking push type AC specifications. "Z" type for DC
D Push-turn locking slotted type is positive common specifications
E Push-turn locking lever type only. For other combinations,
please contact SMC.

548
Manifold specifications 10-SYJ7000
Manifold standard
Common SUP / Common EXH
Type 20 (5 port / Body ported) How to Order
A, B port 10-SS5YJ7-20- 05 -

Air cylinder
P,R port
thread type
Stations
Nil Rc
02 2 stations Applicable solenoid valve
00F G 01
P port 1/8 : : 10-SYJ7첸23-첸첸첸첸-C6
00N NPT C8
15 15 stations 00T NPTF
R port 1/8
Applicable blanking

Rotary actuator
Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
plate assembly
Type 21 (5 port / Body ported) How to Order SYJ7000-21-1A
A, B port 10-SS5YJ7-21- 05 - Applicable individual
P,R port EXH spacer assembly
Stations thread type
02 2 stations SYJ7000-17-1A
Nil Rc
P port 1/4 : :
00F G
20 20 stations

Air gripper
00N NPT
R port 1/4 00T NPTF
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

Type 40 (5 port / Base mounted) How to Order


P port 1/4 10-SS5YJ7-40- 05 - 01

Directional control
Stations A, B port size Thread type
02 2 stations 01 1/8 Nil Rc

valve
: : F G
R port 1/4 N NPT
20 20 stations
T NPTF
A, B port 1/8
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port. Applicable solenoid valve
Type 41 (5 port / Base mounted) How to Order 10-SYJ7첸43-첸첸첸첸

Flow control
10-SS5YJ7-41- 05 - 01

equipment
Applicable blanking
plate assembly
P port 1/4 Stations A, B port size Thread type SYJ7000-21-1A
02 2 stations 01 1/8 Nil Rc Applicable individual
: : F G EXH spacer assembly
N NPT SYJ7000-17-2A
20 20 stations

control equipment
Filter, Pressure
A, B port 1/8 T NPTF
R port 1/4 Applicable individual
Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. SUP spacer assembly
Type 42 (5 port / Base mounted) How to Order SYJ7000-16-2A
10-SS5YJ7- 42- 05 - C6
Stations A, B port size Thread type
02 2 stations C6 One-touch fitting for ø6 Nil Rc

Fittings & Tubing


P port 1/4 F G
: : C8 One-touch fitting for ø8
20 20 stations N7 One-touch fitting for ø1/4" N NPT
A, B port T NPTF
C6, C8 R port 1/4 N9 One-touch fitting for ø5/16"
Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. Air preparation
equipment

Flat ribbon cable manifold


Common SUP / Common EXH
Applicable solenoid valve
Type 21P (5 port / Body ported) How to Order Refer to page 548.
10-SS5YJ7-21P - 05 -
Pressure switch

A, B port
Applicable blanking
Stations P, R port plate assembly
thread type SYJ7000-21-3A
P port 1/4 03 3 stations
Nil Rc
: : Applicable connector
00F G
12 12 stations 00N NPT assembly
00T NPTF Refer to page 548.
Clean gas filter

R port 1/4
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.

549
Manifold specifications 10-SYJ7000

<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base Mix installation of 10-SYJ700 and 10-SYJ7000 valves on the same manifold
Round head combination screw Round head combination screw 앬 Use of an adapter plate makes it possible to mount series 10-SYJ700 on the manifold bases of
M3 x 31 series 10-SYJ7000.
M3 x 31
앬 When mounting the 10-SYJ700 valve on the 10-SYJ7000 manifold, the 10-SYJ700 solenoid
Matt nickel plated Matt nickel plated must be positioned on the same side of a single solenoid of the 10-SYJ7000.
(With spring washer) (With spring washer) 앬 For base mounted style, the A port of the 3 port valve become the B port of manifold base.

Adaptor plate assembly Adaptor plate assembly


SYJ700-3-1A SYJ700-3-2A
Series 10-SYJ700 body ported type Series 10-SYJ700 base mounted type

Gasket Gasket
DXT199-21-10 DXT199-21-11

Round head
Applicable base Applicable base combination screw
· 10-SS5YJ7-20 · Sub-plate Round head
· 10-SS5YJ7-21 · 10-SS5YJ7-40 combination screw
· 10-SS5YJ7-41
· 10-SS5YJ7-42
Individual EXH spacer assembly
SYJ7000-17-1 A Thread type
SYJ7000-17-2 A Thread type
Round head Nil Rc Round head Nil Rc
F G F G
Gasket
combination screw combination screw
N NPT N NPT
T NPTF T NPTF
Round head

7
Round head combination screw

7
combination screw
B
B

Adaptor plate Adaptor plate


A
A

O-ring
Manifold gasket
15
15

Individual R2 Individual R2
exhaust spacer exhaust spacer Applicable base Applicable base
· 10-SS5YJ7-20 · 10-SS5YJ7-40
R
R1 R1
R
· 10-SS5YJ7-21 · 10-SS5YJ7-41
· 10-SS5YJ7-42

Manifold Manifold
gasket gasket Blanking plate assembly
Applicable base Applicable base SYJ7000-21-1A
· 10-SS5YJ7-20 · 10-SS5YJ7-40
Round head combination screw
· 10-SS5YJ7-21 · 10-SS5YJ7-41
· 10-SS5YJ7-42
Individual SUP spacer assembly
SYJ7000-16-2 A Blanking plate Applicable base
· 10-SS5YJ7-20
Round head · 10-SS5YJ7-21
combination screw Gasket · 10-SS5YJ7-40
Thread type · 10-SS5YJ7-41
Nil Rc SYJ7000-21-3A · 10-SS5YJ7-42
F G
B

N NPT Round head


T NPTF combination screw
A

Blanking plate

Gasket
15

Individual
SUP spacer
P

Applicable base
Manifold Dust cap
· 10-SS5YJ7-40
gasket
· 10-SS5YJ7-41
Applicable base
· 10-SS5YJ7-42
Caution · 10-SS5YJ7-21P

Mounting screw tightening torque Use caution to the assembly orientation of solenoid valves, gasket, and optional parts.
M3: 0.8N·m
550
Manifold specifications 10-SYJ7000
Type 20: Top ported / 10-SS5YJ7-20- Stations -00 ∗ [ ]: AC

Grommet (G)
(Lead wire length)
Approx. 300

Air cylinder
L1 4-ø4.5
L2 6 (For mounting)

(DIN: 7.8)
(DIN: 21.6)

Rotary actuator
15.5
3

6.5
3.3
20.3

8
122[126.4]

107.4[111.8]
17 16.5
A

25
R

(DIN: 57.8)
(DIN: 58.6)

17 17
56.5

78.7[80.9]
57.3

50
79.5[81.7]

P
P

R
R

Air gripper
1/8 (P, R port)

1/8 (A, B port)


Manual override (Pitch)
P = 19 20

Directional control
Built-in One-touch fitting

valve
(Station n) (Station 1)

(Light/surge voltage suppressor) One-touch fitting


(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
55.5[62.5]

-+ -+ -+ -+ -+

Flow control
equipment
ø8, ø5/16"
40.1
23.5

control equipment
(4.9) 60

Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7

Fittings & Tubing


MAX.10

55.5[62.5] 89
40.1 Pg7 81.5
(Lead wire length)
70.2
Approx. 300 66.6[73.6] M8 x 1 Air preparation
equipment
3.3
3.3

3.3

3.3
161.8
141.8[146.2]

122.2[126.6]
127.2[131.6]

107.6[112]

125.2
160

140
145.4

147.2

125.4

110.6
78.8[81]
88.6[90.8]

80.3
87.7
97.7

98.6

Pressure switch
0.8

0.8

42.5
0.8
0.8

60
0.8

0.8

∗ Refer to page 563 for dimensions with connector cable.


Clean gas filter

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 stations


L1 59 78 97 116 135 154 173 192 211 230 249 268 287 306
L2 47 66 85 104 123 142 161 180 199 218 237 256 275 294

551
Manifold specifications 10-SYJ7000
Type 21: Top ported / 10-SS5YJ7-21- Stations (-00 ) ∗ [ ]: AC

Grommet (G)
(Lead wire length)
Approx. 300

L1
4-ø4.5
L2 10 (For mounting)

(DIN: 2.8)
(DIN: 16.6)

16.5
3 11.5
15.3

1.5
122[126.4]

107.4[111.8]
R
A

30
R

(DIN: 62.8)
(DIN: 63.6)

21
61.5

83.7[85.9]
62.3
84.5[86.7]

17

21

60
P
P

21
R
R

1/4 (P, R port)

Manual override (Pitch)


1/8 (A, B port)
P = 19 23.5
Built-in One-touch fitting

(Station n) (Station 1)

(Light/surge voltage suppressor)


One-touch fitting
(A, B port)
58.5[65.5]

-+ -+ -+ -+ -+
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
43.1
26.5

(4.9) 63

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
Applicable cable O.D.
(Lead wire length)
Approx. 300

ø3.5 to ø7
MAX.10

58.5[65.5] 92
84.5
43.1 Pg7
73.2
(Lead wire length)
Approx. 300 69.6[76.6] M8 x 1
141.8[146.2]

122.2[126.6]
127.2[131.6]

107.6[112]

161.8

125.2
160

140
145.4

125.4

110.6
83.8[86]

147.2
93.6[95.8]

85.3
92.7
102.7

103.6
0.8

0.8

45.5
0.8
0.8

63
0.8

0.8

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388

552
Manifold specifications 10-SYJ7000
Type 40: Bottom ported / 10-SS5YJ7-40- Stations -01 ∗ [ ]: AC

(Lead wire length)


Approx. 300
Grommet (G)
L1

Air cylinder
4-ø4.5
L2 10 (For mounting)

16.5

(DIN: 16.6)

(DIN: 2.8)
11.5

15.3
0.5

1.5

Rotary actuator
122[126.4]

107.4[111.8]
R
A A A A A
(DIN: 63.6)

30
R

(DIN: 62.8)

21 21
83.7[85.9]
84.5[86.7]
62.3

61.5
21

60
P
P

B B B B B

R
R

1/4 (P, R port)

Air gripper
Manual override (Pitch)
P = 19 23.5
(Station n) (Station 1)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+
58[65]

Directional control
42.6
26

valve
B B
19
40

Flow control
equipment
A A

1/8 (A, B port)

(Pitch) 2
23.5

control equipment
P = 19

Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
Applicable cable O.D.
(Lead wire length)
Approx. 300

ø3.5 to ø7
MAX.10

91.5

Fittings & Tubing


58[65]
84
42.6 Pg7
72.7
(Lead wire length)
Approx. 300 69.1[76.1] M8 x 1
Air preparation
141.8[146.2]

122.2[126.6]

equipment
127.2[131.6]

107.6[112]

161.8

125.2
160

140
145.4

147.2

125.4

110.6
83.8[86]
93.6[95.8]

85.3
92.7
102.7

103.6

Pressure switch
0.8

0.8

45
0.8

0.8

62.5
0.8
0.8

∗ Refer to page 563 for dimensions with connector cable.


Clean gas filter

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388

553
Manifold specifications 10-SYJ7000
Type 41: Side ported / 10-SS5YJ7-41- Stations -01 ∗ [ ]: AC

Grommet (G)

(Lead wire length)


Approx. 300
L1
14 L2

31.5
20.5

85.2[87.4]
86[88.2]

107.4[111.8]
R
R
B B B B B
(DIN: 65.1)

(DIN: 64.3)
122[126.4]

19 19
63.8

19
63

60
P
P

31.5
22
A A A A A

R
R
(DIN: 15.1)

1/4 (P, R port)


13.8

4-ø4.5
(Pitch)
29 P = 20 (For mounting)

Manual override

(Station 1) (Station n)
(Light/surge voltage suppressor)

-+ -+ -+
73[80]
57.6

A A
10.5

41
30.5

B B

6.5 1/8 (A, B port)


(Pitch)
25 P = 20

L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
106.5
99
73[80] 87.7
M8 x 1 77.5
0.8
0.8

57.6 60
0.8

0.8
0.8

0.8
95.1[97.3]

105.1
104.2
85.3[87.5]
127.2[131.6]

94.2
107.6[112]

86.8
141.8[146.2]

122.2[126.6]

145.4

147.2

125.4

110.6
161.8

125.2
160

140

84.1[91.1]
Approx. 300
(Lead wire length)
(Lead wire length)

MAX.10

Pg7 Applicable cable O.D.


Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 78 98 118 138 158 178 198 218 238 258 278 298 318 338 358 378 398 418 438
L2 50 70 90 110 130 150 170 190 210 230 250 270 290 310 330 350 370 390 410

554
Manifold specifications 10-SYJ7000
Type 42: Side ported / 10-SS5YJ7-42- Stations - C6,N7
C8,N9 ∗ [ ]: AC

Grommet (G)

(Lead wire length)


Approx. 300

Air cylinder
L1
Manual override
14 L2
4-ø4.5
(For mounting) 32.5
19

Rotary actuator
85.9[88.1]

85.1[87.3]
107.4[111.8]
(DIN: 64.2)
R
B B B B B

R
(DIN: 65)
122[126.4]

18 18.5
62.9
63.7

59.9
21.9 19
P
P

31.4
A A A A A

R
R
(DIN: 15.2)

(4.9)
13.9

Air gripper
1/4 (P, R port)
(Pitch)
29 P = 19

Directional control
(Station 1) (Station n)
(Light/surge voltage suppressor)

valve
-+ -+ -+
74[81]
58.6

A A
42
29.5
8.5

B B

Flow control
equipment
8 (Pitch)
25 P = 19 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"

control equipment
Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
107.5
74[81] 100 M8 x 1
88.7

Fittings & Tubing


0.8
0.8

78.5
58.6
0.8

61
0.8

0.8
0.8
95[97.2]

85.2[87.4]

104.1

105
127.2[131.6]

94.1
107.6[112]
141.8[146.2]

122.2[126.6]

86.7
145.4

147.2

125.4

110.6
161.8

125.2
160

140

Air preparation
equipment

85.1[92.1]
Approx. 300
Pressure switch

(Lead wire length)


Pg7
(Lead wire length)

Applicable cable O.D.


MAX.10
Approx. 300

ø3.5 to ø7

∗ Refer to page 563 for dimensions with connector cable.


Clean gas filter

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 77 96 115 134 153 172 191 210 229 248 267 286 305 324 343 362 381 400 419
L2 49 68 87 106 125 144 163 182 201 220 239 258 277 296 315 334 353 372 391

555
Manifold specifications 10-SYJ7000

Flat ribbon cable manifold ∗ [ ]: AC

10-SS5YJ7-21P- Stations (-00 )

(Lead wire length)


Approx. 300
L1
L2 10

- +
4-ø4.5
(For mounting)
- + - +
16.5
1/8 (A, B port)

1.5
15.3

11.5
141.8[146.2]

127.2[131.6]
17 21.5

21 19.5
R
R

30
A

21 21
61.5
62.3

93.6[95.8]
94.4[96.6]

60
P
P

93.8
B

R
R

16
- + - + - + - + - +

Manual override (Non-locking) (Pitch) Triangle mark 1/4 (P, R port)


P = 20.5 23.5

(Station n) (Station 1)
(Light/surge voltage suppressor)
58.5[65.5]

32.3
26.5

28.5
8.8

Applicable connector: 26 pins MIL type


(Conforming to MIL-C-83503)

With built-in One-touch fitting

One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"

(4.9) 63

Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations


L1 88 108.5 129 149.5 170 190.5 211 231.5 252 272.5
L2 68 88.5 109 129.5 150 170.5 191 211.5 232 252.5

556
Series 10-SYJ5000/7000
Made to order specifications
DIN terminal connector conforming to EN-175301-803C
(former DIN 43650C) standard

DIN terminal type conforming to DIN 43650C (DIN pitch 8mm) standard

Air cylinder
How to Order Valves
Light/surge voltage suppressor
Type of actuation
Nil Without light/surge voltage suppressor
1 2 position single solenoid
S With surge voltage suppresser
2 2 position double solenoid
Z With light/surge voltage suppresser Bracket
3 3 position closed center

Rotary actuator
∗ "YOZ" is not available. Nil Without bracket
4 3 position exhaust center ∗ For AC voltage valves, there is no "S" F With bracket
5 3 position pressure center option. It is already built-in to the
rectifier circuit. Note) Do not remove the factory
installed bracket from
models with the bracket
Rated voltage A, B port size option. Removal of the
DC specifications AC specifications (50/60Hz) M5 M5 x 0.8 bracket will cause air
5 24 VDC 1 100 VAC 01 1/8 (10- SYJ7000 only) leakage.
6 2

Air gripper
12 VDC 200 VAC C4 One-touch fitting for ø4
3 110 VAC [115 VAC] C6 One-touch fitting for ø6
4 220 VAC [230 VAC] N3 One-touch fitting for ø5/32"
N7 One-touch fitting for ø1/4

Directional control
Body ported 10 SYJ 5 1 23 5 Y M5

valve
Base mounted 10 SYJ 5 2 43 5 Y
Series Electrical entry Thread type

Flow control
equipment
5 10-SYJ5000 Nil Rc
Y: With connector F G
7 10-SYJ7000
N NPT
T NPTF

Port size
Nil Without sub-plate

control equipment
Filter, Pressure
10-SYJ5000
1 1/8
YO: Without connector 10-SYJ7000
2 1/4 10-SYJ7000

Manual override
Nil Non-locking push type
D Push-turn locking slotted type

Fittings & Tubing


E Push-turn locking lever type

How to Order Pilot Valve Assembly

10 V115 5 Y DIN connector part no.


Without light SY100-82-1
Rated voltage With light
Air preparation

Rated voltage Voltage symbol Part no.


equipment

DC specifications 24 VDC 24VN SY100-82-3-05


5 24 VDC 12 VDC 12VN SY100-82-3-06
Light/surge voltage suppressor
6 12 VDC 100 VAC 100VN SY100-82-3-01
Nil Without light/surge voltage suppressor
AC specifications (50 60 Hz) 200 VAC 200VN SY100-82-3-02
S With surge voltage suppresser
1 100 VAC 110 VAC [115 VAC] 110VN SY100-82-3-03
Z With light/surge voltage suppresser
2 200 VAC 220 VAC [230 VAC] 220VN SY100-82-3-04
Pressure switch

∗ "YOZ" is not available.


3 110 VAC [115 VAC] ∗ For AC voltage valves, there is
4 220 VAC [230 VAC] no "S" option. It is already built-in Caution
to the rectifier circuit. 1. Use caution in wiring because it won't meet the IP65 (enclosure) standard if you
use the other cord than prescribed cabtire cable of size (ø3.5 to ø7).
Also be sure to tighten the ground nut and set screw within the specified range of
torque.
Electrical entry For how to use DIN terminal (wiring procedures, procedures for changing electrical
entries, precautions, applicable cable, circuit diagram), refer to page 560.
Y With connector
Clean gas filter

DIN terminal 2. D type DIN connector with 9.4 mm pitch between terminals is not interchangeable.
YO Without connector 3. DIN connector except D type has the "N" indication in the end of voltage symbol. In
case of DIN connector without light, "N" is not indicated. Please refer to the name
plate to distinguish.
4. Dimensions are completely the same as D type connector.
5. When exchanging the pilot valve assembly only, "10-V115-첸D" is interchangeable
with "10-V115-첸Y". Do not replace 10-V114 (G, H, L, M, W) to 10-V115-첸D/첸Y
(DIN terminal), and vice versa.

557
Series 10-SYJ3000/5000/7000
Specific Product Precautions 1
Be sure to read before handling.

Manual override operation Solenoid valve for 200/220 VAC specifications

Warning Warning
When the manual override is operated, connected equipment will Solenoid valves with grommet and L/M type plug connector AC
be actuated. Confirm safety before operating. specificatinos have a built-in rectifier circuit in the pilot section to
operate the DC coil.
왎Non-locking push type (Standard) With 200/220 VAC specification pilot valves, this built-in rectifier
Press in the direction of the arrow. generates heat when energized. The surface may become hot
depending on the energized condition. Therefore, do not touch
the solenoid valves.

Series 10-SYJ3000, 5000, 7000


왎Push-turn locking slotted [Type D] Mixed installation of 3 port and 5 port valves
While pressing, turn in the direction of the arrow.
on the same manifold.
If it is not turned, it can be operated in the same way as the
non-locking type.
Locked position Caution
Series 10-SYJ3000/5000/7000 and Series 10-SYJ300/500/700
can be mounted on the same manifold. How to mount on the
PUSH

LOCK

same manifold is shown on the following pages.


10-SYJ3000, 10-SYJ300 ········· Page 507
10-SYJ5000, 10-SYJ500 ········· Page 529
Caution 10-SYJ7000, 10-SYJ700 ········· Page 550
When handling the locking type D with a screwdriver, turn it If 4 or 5 port valve is used as a 3 port valve
gently using a watchmaker's screwdriver. Series 10-SY 3000/5000/7000 may be used as a N.C. or N.O. 3
[Torque: 0.1 N·m or less] port valve by plugging one of the A, B ports. Be sure not to plug
the exhaust ports (R). Can be used when a double solenoide, 3
왎Push-turn locking lever [Type E] port valve is required.
While pressing, turn in the direction of the arrow.
If it is turned, it can be operated in the same way as the non- Plug position B port A port
Type of actuation N.C. N.O.
locking type.
Number of solenoids

(A) (B) Plug (A) (B)


4 2 Plug 4 2
Single

Locked position
5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
LOCK
PUSH

(A) (B) Plug (A) (B)


4 2 Plug 4 2
Double

5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)

(JIS Symbols above: Series 10-SYJ5000)


Caution
When locking the manual override on the push-turn locking
types (D, E), be sure to push it down before turning.
Turning without first pushing it down can cause damage to the
manual override and trouble such as air leakage, etc.

558
Series 10-SYJ3000/5000/7000
Specific Product Precautions 2
Be sure to read before handling.

Air cylinder
How to use plug connector Plug connector lead wire length

Caution Caution

Rotary actuator
1. Attaching and detaching connectors Standard length is 300 mm, but the following lengths are also
앬 To attach a connector, hold the lever and connector unit available.
between your fingers and insert straight onto the pins of the
solenoid valve so that the lever's pawl is pushed into the How to Order Connector Assembly
groove and locks.
For DC: SY100 30 4A
앬 To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the

Air gripper
For 100 VAC: SY100 30 1A
connector straight out.
Cover
Groove For 200 VAC: SY100 30 2A
Pin
Cover
Groove For other voltages of AC: SY100 30 3A

Directional control
Lever
Pin
DC polarity display
Without lead wire: SY100 30 A Lead wire

valve
-+

Socket (with connector and 2 of sockets only) length


Connector Lead wire Nil 300mm
How to Order
6 600mm
Hook Specify the connector assembly part
10 1000mm
number together with the part number for 15 1500mm
2. Crimping of lead wires and sockets the plug connector's solenoid valve without 20 2000mm

Flow control
equipment
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the connector. 25 2500mm
ends of the core wires evenly into the sockets, and then crimp <Example> Lead wire length 2000 mm 30 3000mm
50 5000mm
with a crimping tool. (For DC) For AC
When this is done, take care that the coverings of the lead 10-SYJ3123-5LO-M3 10-SYJ3123-1LO-M3
wires do not enter the core wire crimping area. SY100-30-4A-20 SY100-30-1A-20

control equipment
Filter, Pressure
Use an exclusive crimping tool for crimping.
(For special crimping tools, please contact SMC.)
Core wire crimping area Crimping area
Socket Core wire
Lead wire 0.2 to 0.33mm2
Max. cover diameter: ø1.7 mm

Fittings & Tubing


Hook Insulation

3. Attaching and detaching sockets with lead wires


앬 Attaching
Insert the sockets into the square holes of the connector
( + and - indication), and continue to push the sockets all
the way in until they lock by hooking into the seats in the
Air preparation
equipment

connector. (When they are pushed in, their hooks open and
they are locked automatically.) Then confirm that they are
locked by pulling lightly on the lead wires.
앬 Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket's hook with a stick having a thin tip
Pressure switch

(approx. 1 mm).
If the socket will be used again, first spread the hook
outward.

Socket Connector
Clean gas filter

Lead wire
Hook

559
Series 10-SYJ3000/5000/7000
Specific Product Precautions 3
Be sure to read before handling.

Surge voltage suppressor

Caution
(For DC)
Grommet, L/M plug connector type DIN terminal
왎Standard type (with polarity) With surge voltage suppresser (DS)
With surge voltage suppresser (첸S)

Varistor
Diode to prevent reverse current

Coil
Red (+)

Black (–) Coil


With light/surge voltage suppresser (DZ)
With light/surge voltage suppresser (첸Z)
Diode to prevent reverse current

Varistor
Red (+)

Coil
Coil

Black (–)
DIN terminal has no polarity.
왎Non-polar type
With surge voltage suppresser (첸R)
(–) (+) M8 connector type
Coil

Varistor (Ground) 왎Standard type (with polarity)


(+) (–) With surge voltage suppresser (첸S)
4
With light/surge voltage suppresser (첸U) Diode to prevent reverse current
(–) (+)
1 (+)
Coil

Coil
Varistor
1 3
(+) (–)
3 (–)
· Connect the standard type in accordance with the +, – polarity
indication. Solenoid valve side
(The non-polar type can be used with the connections made Pin wiring diagram With light/surge voltage suppresser(첸Z)
either way.) Diode to prevent reverse current

· Since voltage specifications other than standard 24 and 12 VDC 1 (+)


do not have diodes for polarity protection, be careful not to

Coil
make errors in the polarity.
· Be careful about the allowable voltage fluctuation since the 3 (–)
valves with a diode to prevent reverse current has about a 1V
voltage drop. (Refer to the solenoid specifications of each valve 왎Non-polar type
for details.) With surge voltage suppresser (첸R)
(Ground)
· When wiring is done at the factory, positive (+) is red and 1 (–) (+)
negative (–) is black. 4
Coil

왎With power saving circuit Electric circuit (with power saving circuit)
Varistor
3 (+) (–)
Power consumption is de- Red (+)
Diode
Timer circuit

creased by 1/4 by reducing 1 3


Coil

LED
the wattage required to hold With light/surge voltage suppresser (첸U)
the valve in an energized 1 (–) (+)
1 2
state. (Effective energizing Black (–) Solenoid valve side
Coil

1: Starting current 2: Holding current Varistor


time is over 62 ms at 24 VDC.) Pin wiring diagram
3 (+) (–)
Working principle
(Energy saving type's electrical power
With the above circuit, the current 3 · In the case of standard type, connect + to 1 and – to 3 according
waveform : SYJ5 첸첸0T)
consumption when holding is re- 7 to the polarity.
duced to save energy. Please refer 24V
Applied voltage · For DC voltages other than standard 12/24 VDC, use caution not
to the electric wave data to the right. to mistake the polarity because a diode to prevent reverse
0V
· When a power saving circuit is in- current is not provided.
stalled, a diode to prevent reverse 0.4W Standard · Be careful about the allowable voltage fluctuation since the
With power
current is not provided. Therefore, 0.1W
saving circuit valves with a diode to prevent reverse current has about a 1V
use caution not to connect in re- 0W voltage drop. (Refer to the solenoid specifications of each valve
62ms
verse. for details.)
· Be careful about the allowable voltage fluctuation since voltage
drop of about 0.5V occurs due to a transistor. (Refer to the sole-
noid specifications of each valve for details.)

560
Series 10-SYJ3000/5000/7000
Specific Product Precautions 4
Be sure to read before handling.

Air cylinder
Surge voltage suppressor How to use DIN Terminal
<For AC> Ground nut
(There is no "S" type because the generation of surge voltage is Tightening torque

Rotary actuator
prevented by a rectifier.) 1.65 to 2.5 N·m
Holding screw
Tightening torque
Grommet, L/M plug connector 0.4 N·m
Washer
With indicator light (첸Z) Grommet
(~)
(Rubber) Housing
Varistor

Coil
(Rating symbol)
Refer to table of
(~) DIN connector part no. (Light mounting
location )

Air gripper
Terminal screw Terminal block
DIN terminal (3 locations) Notch
With indicator light (DZ) Tightening torque
(~)
0.2 to 2.5 N·m
Varistor

Coil

Directional control
(~) DIN connector part no.
NL : Neon ball

valve
Note) Surge voltage suppressor of varistor has residual voltage
corresponding to the protective element and rated voltage. Caution
Therefore, protect the controller side from the surge.
The residual voltage of the diode is approximately 1 V. Without light SY100-61-1
With light

Flow control
Rated voltage Voltage symbol Part no.

equipment
How to use DIN Terminal 24 VDC 24V SY100-61-3-05
12 VDC 12V SY100-61-3-06

Caution 100 VAC


200 VAC
100V
200V
SY100-61-2-01
SY100-61-2-02
Connection 110 VAC 110V SY100-61-2-03
1. Loosen the holding screw and pull the connector out of the 220 VAC 220V SY100-61-2-04

control equipment
Filter, Pressure
solenoid valve terminal block.
2. After removing the holding screw, insert a flat head Circuit diagram with light
screwdriver, etc. into the notch on the bottom of the terminal AC circuit DC circuit
block and pry it open, separating the terminal block and the
housing.
3. Loosen the terminal screws (slotted screws) on the terminal
block, insert the cores of the lead wires into the terminals

Fittings & Tubing


according to the connection method, and fasten them securely
with the terminal screws.
4. Secure the cord by fastening the ground nut. NL: Neon light LED: Light emitting diode
R: Resistor R: Resistor
Caution Note) Refer to page 557 for DIN connector (Y) conforming to EN-175301-803C (former DIN
When making connections, note that using other than the 43650C).
supported size (ø3.5 to ø7) cabtire cable will not satisfy IP65
(enclosure) standards.
Air preparation
equipment

Also, be sure to tighten the ground nut and holding screw within
their specified torque ranges.

Caution
Changing the entry direction
After separating the terminal block and housing, the cord entry
Pressure switch

can be changed by attaching the housing in the desired direction


(4 directions at 90° intervals).
∗ When equipped with an indicator light, be careful not to damage
the light with the cord's lead wires.
Precautions
Plug in and pull out the connector vertically without tilting to one
Clean gas filter

side.
Compatible cable
Cord O.D.: ø3.5 to ø7
(Reference) 0.5 mm2, 2 core or 3 core, equivalent to JIS C 3306

561
Series 10-SYJ3000/5000/7000
Specific Product Precautions 5
Be sure to read before handling.

Connector assembly with cover M8 connector

Caution Caution
Connector assembly with dustproof protective cover 1. M8 connector types have an IP65 (enclosure) rating, offering
· Effective to prevent short circuit failure due to the entry of foreign protection from dust and water. However please note that
matter into the connector these products are not intended for use in water.
· Chloroprene rubber for electrical use, which provides outstand- Select a SMC connector cable (V100-49-1-첸) or a FA sensor
ing weather resistance and electrical insulation, is used for the type connector, with M8 threaded 3 pin specifications
cover material. However, do not allow contact with cutting oil, conforming to Nippon Electric Control Equipment Association
etc. Standard, NECA4202 (IEC60947-5-2). Make sure the
· Simple and unencumbered appearance by adopting round- connector O.D. is 10.5 mm or less when used with the Series
shaped cord. 10-SY3000 manifold. If more than 10.5mm, it cannot be
mounted due to the size.
How to Order 2. Do not use a tool to mount the connector, as this may cause
damage. Only tighten by hand. (0.4 to 0.6N)
SY100-68-A 3. Do not apply excessive power greater than 30N to the connec-
Lead wire length tor cable, otherwise IP65 cannot be satisfied.
Nil 300mm
6 600mm
Caution
10 1000mm Failure to meet IP65 performance may result if using alternative
15 1500mm connectors than shown above, or when insufficiently tightened.
20 2000mm
25 2500mm · Connector cable mounting
30 3000mm
50 5000mm
Triangle mark
Arrow mark
Connector assembly with cover: Dimensions
(40) Gray

(10)
(ø4.1)
(6.9)

Red Black (8)


(8)

Note) Connector cable should be mounted in the correct direc-


tion. Make sure that the arrow symbol on the connector is
(14.5) L facing the triangle symbol on the valve when using SMC
connector cable (V100-49-1-첸).
Be careful not to squeeze it in the wrong direction, as
problems such as pin damage may occur.

MConnector cable
· Connector cable for M8 can be ordered as follows:

How to Order How to Order


Enter the part number for a plug connector solenoid valve without 1. To order solenoid valve and connector cable at the same time.
connector together with the part number for a connector (Connector cable will be included in the shipment of the solenoid
assembly with cover. valve.)
<Example 1> Lead wire length 2000 mm 3
10-SYJ3123-5LOZ-M3 10 SYJ 57 3
SY100-68-A-20 Electrical entry
<Example 2> Lead wire length 300mm (Standard) W1: Cable length 300 mm
10-SYJ3123-5LPZ-M3 W2: Cable length 500 mm
W3: Cable length 1000 mm
Symbol for connector assembly with cover W4: Cable length 2000 mm
W7: Cable length 5000 mm
∗ In this case, the part number for the connector assembly with
cover is not required. (Example 1) Cable length 300 mm
10-SYJ3123-5W1ZE-M3
Symbol for electrical entry

562
Series 10-SYJ3000/5000/7000
Specific Product Precautions 6
Be sure to read before handling.

Air cylinder
M8 connector Flat ribbon cable manifold
2. To order connector cable only Internal wiring of manifold

Rotary actuator
(Ground) Connector dimensions
4 Brown: 1 Blue: 3 Station 12 Station 4 Station 3 Station 2 Station 1
Coil
ø9

3 1
Black: 4 Side A Side B Side A Side B Side A Side B Side A Side B Side A Side BTriangle mark
33.9 Coil Coil Coil Coil Coil Coil Coil Coil Coil Coil Indicated position

L 35 10 25 23
7 5 3 1 Note)
Connector

Air gripper
26 24
8 6 4 2
Cable length (L) Part no.
300mm V100-49-1-1

) ( ) Side A Coil
) ( ) Side B Coil

( ) ( ) Side A Coil
) ( ) Side B Coil

) ( ) Side A Coil
) ( ) Side B Coil

) ( ) Side A Coil
) ( ) Side B Coil

) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Common
) ( ) Common
500mm V100-49-1-2
1000mm V100-49-1-3
2000mm V100-49-1-4 + +

Directional control
+ + + + + + + + + +
5000mm V100-49-1-7
-
-
{((

-
-

-
-

-
-
-
-
-
-

{ ((
{(

{ ((

{ ((
{ ((
Connected

valve
on the
22 33.9 board Station 12 Station 4 Station 3 Station 2 Station 1
1
Triangle mark 2
(Max. 12 stations)
3
24
25
Reference figure 26
Note)
14

Flow control
equipment
Terminal no. is not indicated on the connector. The terminal no.
indicated in the connection schematic of connector, as shown in
the reference, means a correlation of 1, 2, 3···26 from the triangle
mark side on the flat ribbon cable of connector.
Flat ribbon cable manifold
· For more than 10 stations, both poles of the common should be

control equipment
Caution wired.

Filter, Pressure
· For single solenoid, connect to the solenoid B side.
Type 21P Type 32P · The maximum number of stations that can be accommodated is
12. Please contact SMC for more stations.
· Only non-polar valves are available for the DC flat ribbon cable
manifold, therefore negative COM or positive COM wiring of the
manifold is possible. The valve dose not switch with negative

Fittings & Tubing


COM if a Z type is used. Be sure to use positive COM.

Bracket
• In the manifold valves, the wiring to the individual valves is
provided on a printed circuit board, and the connection to the
external wires is consolidated through the use of a flat cable.
Caution
For 10-SYJ3000 (Single) or 10-SYJ7000 with bracket, do not use
•A single MIL flat cable connects the entire manifold to your
Air preparation

it without bracket.
equipment

power source. This greatly reduces installation time and


provides clean appearance.

Replacement of solenoid valve

Caution
Pressure switch

Mount it so that there is no slippage or deformation in gaskets,


and tighten with the tightening torque as shown below.

Model Thread size Tightening torque


10-SYJ3000 M1.7 0.12N·m
10-SYJ5000 M2.5 0.45N·m
Clean gas filter

10-SYJ7000 M3 0.8N·m

563
Series 10-SYJ3000/5000/7000
Specific Product Precautions 7
Be sure to read before handling.

Replacement of pilot valve

Caution
Pilot valves in this series are improved to provide excellent
energy saving results. However, following this improvement,
these new valves are no longer compatible with the conventional
pilot valve used at the interface. Please consult with SMC when
you need to exchange these pilot valves, in the case of manual
override (marked in orange) of the adapter plate.

New type
Manual override
(Blue)
-+

B
A

Interface

Pilot valve
(10-V111) Adapter plate

Conventional type
Manual override
(Orange)
-+

B
A

Interface

Pilot valve
(10-SY114) Adapter plate

564

You might also like