ES11-84 B
앬 Flow Characteristics
Flow characteristics
Series
C [(dm3/s·bar)] b Cv
SYJ3000 0.46 0.36 0.12
SYJ5000 0.83 0.32 0.21
Cover (stainless steel) SYJ7000 2.9 0.35 0.74
Rubber Seal
4/5 Port Solenoid Valve
Series SYJ3000/5000/7000
Variations
Option
Sonic conductance: Type of Manual
Series Voltage Electrical entry
C [dm3/(s.bar)] actuation With light/surge override
voltage suppressor
SYJ5000
Body ported
P. 23
–+
SYJ7000 2 Position
Single
2.4
Double M plug connector
4/2 → 5/3
{ (A/B → EA/EB) }
+–
For AC
P. 47 Non-locking
3 Position push type
SYJ3000 Closed
100 VAC /60 Hz
50
center
220 VAC 50/60 Hz
SYJ5000
0.83 Push-turn
4/2 → 5/3
{ (A/B → EA/EB) } locking
lever type
(SYJ5000, 7000
only)
P. 23
SYJ7000 M8 connector
2.9
4/2 → 5/3
{ (A/B → EA/EB) }
P. 47
Note) All AC voltage models have built-in surge voltage suppressor.
Front matter 1
Series SYJ3000/5000/7000
Manifold Variations
A, B port size Manifold option
SYJ3000 — — — — — — — — — — —
Body ported
SYJ5000 Top — — — — —
SYJ7000 — — — — — —
Side — — — — —
SYJ3000 — — —
Bottom — — — — — — — — — —
Base mounted
Side — — — —
SYJ5000
Bottom — — — — — — — — (P port —
regulation)
Side — — — — —
SYJ7000
Bottom — — — — — — — — (P port —
regulation)
R port P
Base mounted
P port
Type 32P
Individual EXH
R port
A, B port
spacer assembly
R2
-+
-+ R1
R
R port
P
A, B port
P port Mixed mounting of 3 port
valves and 4, 5 port valves
-+
Interface 4, 5 port valve
3 port valve
-+
R
R port regulator
P
A
A, B port B
P port
-+
-+
R
P
A
-+ B
-+
B
P
R R port
A, B port A For detailed specifications about
B
P port SYJ3000, refer to page 14. For
SYJ5000, refer to page 38, and for
SYJ7000, refer to page 61.
Front matter 2
Rubber Seal
4/5 Port Solenoid Valve
Fluid Air
2 position single 0.15 to 0.7
Operating pressure range
MPa 2 position double 0.1 to 0.7
3 position 0.2 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing. Refer to back page 3.)
Response time (ms) Note 1) 2 position single, double 15 or less
(at 0.5 MPa) 3 position 30 or less
Max. operating 2 position single, double 10
frequency (Hz) 3 position 3
Body ported
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Individual exhaust for the pilot valve, Common exhaust for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
Note 2)
Shock/Vibration resistance (m/s2) 150/30
Enclosure Dust proof (∗ M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge
voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the
main valve and armature in both energized and de-energized states every once for each
condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to
axis and right angle directions of the main valve when pilot signal is ON and OFF. (Value in
the initial state)
Base mounted
Solenoid Specifications
JIS Symbol
5 port 4 port (manifold)
Electrical entry Gromet (G), (H), L plug connector (L),
2 position single 2 position single M plug connector (M), M8 connector (W)
(B) (A) (B) (A)
2 4 2 4 DC 24, 12, 6, 5, 3
Coil rated voltage (V)
AC 50/60 Hz 100, 110, 200, 220
3 1 5
(R) (P) (R)
1 3 Allowable voltage fluctuation ±10% of rated voltage ∗
(P) (R)
2 position double 2 position double Standard 0.35 (With light: 0.4)
(B) (A) (B) (A) Power consumption (W) DC
2 4 2 4 With power saving circuit 0.1 (With light only)
100 V 0.78 (With light: 0.81)
3 1 5 0.86 (With light: 0.89)
(R) (P) (R) 1 3 110 V
(P) (R) [0.94 (With light: 0.97)]
[115 V]
3 position closed center 3 position closed center Apparent power VA ∗ AC
(B) (A) (B) (A) 200 V 1.18 (With light: 1.22)
2 4 2 4
220 V 1.30 (With light: 1.34)
[230 V] [1.42 (With light: 1.46)]
3 1 5
(R) (P) (R) 1 3
(P) (R) Surge voltage suppressor Diode (Non-polarity type: Valistor)
3 position exhaust center 3 position exhaust center Indicator light LED
(B) (A) (B) (A)
2 4 2 4 ∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VDC and 230 VDC, the allowable voltage is –15% to +5% of rated voltage.
∗ S, Z and T type (with power saving circuit) should be used within the following allowable voltage fluctuation range due to
3 1 5 a voltage drop caused by the internal circuit. S and Z type: 24 VDC: –7% to +10%, 12 VDC: –4% to +10%
(R) (P) (R) 1 3
(P) (R) T type: 24 VDC: –8% to +10%, 12 VDC: –6% to +10%
3 position pressure center 3 position pressure center
(B) (A)
2 4
(B) (A)
2 4
Bracket Mounting
q Insert the lower hook of the mounting bracket into w Press the valve and mounting bracket together
3 1 5
(R) (P) (R) 1 3 the groove on the bottom of the valve as shown. until the upper hook of the bracket snaps into
(P) (R) place in the groove on top of the valve.
Made to Order
(For details, refer to page 79.)
1
Series SYJ3000
Flow Characteristics/Weight
Base Mounted
Bore size
Series CJ2 Series CM2
Average
Pressure 0.5 MPa Pressure 0.5 MPa
Series speed Load rate: 50% Load rate: 50%
(mm/s) Stroke 60 mm Stroke 300 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40
800
700 Perpendicular, upward actuation
600
500 Horizontal actuation
SYJ3140-M5 400
300
200
100
0
∗ Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
∗ Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
∗ Load factor: ((Load weight x 9.8) /Theoretical force) x 100%
Conditions
Body ported Series CJ2 Series CM2 Base mounted Series CJ2 Series CM2
Tubing bore x Length ø4 x 1 m Tubing bore x Length ø6 x 1 m
SYJ3120-M3 Speed controller AS1301F-04 SYJ3140-M5 Speed controller AS2001F-06 AS2301F-06
Silencer AN120-M5 Silencer AN120-M5
2
Series SYJ3000
How to Order
Light/surge voltage suppressor Bracket
Type of actuation Nil Without light/surge voltage suppressor Nil: Without bracket
1 2 position single solenoid S With surge voltage suppresor F: With bracket
2 2 position double solenoid Z With light/surge voltage suppressor
3 3 position closed center R With surge voltage suppressor (Non-polar type)
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
5 3 position pressure center ∗ For AC voltage valves there is no “S” option.
-+
It is already built-in to the rectifier circuit.
∗ For type “R” and “U”, DC voltage is only
available. Single Double
∗ Power saving circuit is only available in the ∗ Brackets cannot
5 port Rated voltage "Z" type. be retrofitted.
DC AC (50/60 Hz) Note) • The double solenoid mounting
bracket is supplied unattached.
5 24 VDC 1 100 VAC • To order the double solenoid
6 12 VDC 2 200 VAC bracket for use with a single
V 6 VDC 3 110 VAC [115 VAC] solenoid valve, order the single
S 5 VDC 4 220 VAC [230 VAC] solenoid valve without a bracket
and order the bracket (VJ3000-
R 3 VDC ∗ For type W, DC voltage is only available. 13-1) separately.
(Type 20 Manifold)
(Example) SYJ3120-5M-M3
VJ3000-13-1
For sub-plate,
manifold type 41, S41, 46, S46 R port P, E port R port P, E port
Electrical entry
24, 12, 6, 5, 3 VDC
24, 12, 6, 5, 3 VDC
100,110, 200, 220 VAC
Grommet L plug connector M plug connector M8 connector E: Push-turn locking lever type
G: Lead wire L: With lead wire M: With lead wire MN: Without WO: Without
length 300 mm (Length 300 mm) (Length 300 mm) lead wire connector cable
+– +–
+
–
–+
H: Lead wire LN: Without LO: Without MO: Without W: With connector
length 600 mm lead wire connector connector cable Note 1)
+
–
–+ Note) When placing an order for body ported
solenoid valve as a single unit, mounting
bolt for manifold and gasket are not
attached. Order them separately, if
∗ LN, MN type: with 2 sockets.
necessary. (For details, refer to page 15.)
∗ For connector cable of M8 connector, refer to back page 10.
Note 1) Enter the cable length symbols in . Please be sure
to fill in the blank referring to back page 10.
3
Series SYJ3000
Construction
(A)(B) (A)(B)
2 position single 4 2 2 position double 4 2
5 1 3 5 1 3
(R)(P)(R) (R)(P)(R)
e t qr w wq t r
(A) (B) (A) (B)
4 2 4 2
u u
5 1 3 5 1 3
(R) (P) (R) (R) (P) (R)
y
3 position closed center/exhaust center/pressure center
3 position closed center
(A)(B)
4 2
w t q r
5 1 3
(R)(P)(R)
(A) (B)
3 position exhaust center 4 2
(A)(B)
4 2
5 1 3
(R)(P)(R)
3 position pressure center
(A)(B)
5 1 3
u
4 2
(R) (P) (R)
5 1 3 (This figure shows a closed center type.)
(R)(P)(R)
Coil specifications
Light/surge voltage suppressor
Nil Without light/surge voltage suppressor
For 100 VAC : SY100-30-1A-
Nil Standard S With surge voltage suppresor
T
With power saving circuit Z With light/surge voltage suppressor For 200 VAC : SY100-30-2A-
(24, 12 VDC only) With surge voltage suppressor
R (Non-polar type)
∗ Power saving
circuit is not With light/surge voltage suppressor
For other
voltages of AC
: SY100-30-3A-
available in the U
(Non-polar type)
case of W type.
∗ For AC voltage valves there
is no “S” option. It is already
Without lead wire : SY100-30-A
built-in to the rectifier circuit. (with connector and Lead wire length
∗ For type “R” and “U”, DC 2 of sockets only)
voltage is only available. Nil 300 mm
∗ Power saving circuit is only 6 600 mm
available in the "Z" type. 10 1000 mm
Rated voltage
15 1500 mm
5 24 VDC Electrical entry 20 2000 mm
6 12 VDC G Grommet, 300 mm lead wire 25 2500 mm
V 6 VDC 30 3000 mm
S H Grommet, 600 mm lead wire
5 VDC 50 5000 mm
R 3 VDC L With lead wire
L plug
1 100 VAC 50/60 Hz LN Without lead wire
connector
2 200 VAC 50/60 Hz LO Without connector How to Order M8 Connector Cable
110 VAC 50/60 Hz M With lead wire
3 M plug
[115 VAC 50/60 Hz] MN Without lead wire
4 220 VAC 50/60 Hz MO
connector
Without connector V100-49-1-
[230 VAC 50/60 Hz] WO M8 Without connector cable
∗ For type W, DC W connector With connector cable Note 1)
voltage is only Cable length
∗ For connector cable of M8 connector,
available. refer to back page 10. 1 300 mm
Note 1) Enter the cable length symbols in 2 500 mm
. Please be sure to fill in the 3 1000 mm
blank referring to back page 10. 4 2000 mm
7 5000 mm
4
Series SYJ3000
2 Position Single [ ]: AC
16.4
10
- +
8.2
4
A B
11.5 19.3
7 Manual override
28 [35]
-+
22.1
54.4 [56.6]
13.5
12.6
15
2
R P R (Bracket) 15
11
10
ø1.2 22.1
7 7 (PE port)
15 M5 x 0.8
(P, R port)
28 [35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1 [46.1]
(Lead wire length)
64.3 [66.5]
54.5 [56.7]
63.4
56
49.5
(2)
(2)
(2)
5
Series SYJ3000
2 Position Double [ ]: AC
G
Grommet (G), (H): SYJ3220- H -M3 (-F)
G: Approx. 300
78.8 [83.2] H: Approx. 600
(Lead wire length)
34.4
7.1
1.8
4
8.2
A B
28 [35]
(18.5)
22.1
-+
13.5
12.6
15
(11.5)
0.5
R P R
10
14 ø1.2
(PE port)
M5 x 0.8
(P, R port)
28 [35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1 [46.1]
(Lead wire length)
79 [83.4]
96.8
69
82
15
22.1 15
15
22.1
22.1
6
Series SYJ3000
3
Grommet (G), (H): SYJ3 20- H -M3 (-F)
G
4
5
G: Approx. 300
91.7 [96.1] H: Approx. 600
40.2 [42.4] (Lead wire length)
29.3 18
1.8 5.3
4
8.2
A B
28 [35]
(18.5)
22.1
-+
13.5
12.6
15
(11.5)
0.5
R P R
10
14 ø1.2
(PE port)
M3 x 0.5
(P, R port)
28 [35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1 [46.1]
(Lead wire length)
50.1 [52.3]
40.3 [42.5]
49.2
41.8
35.3
91.9 [96.3]
109.7
46.6
53.1
15
22.1 15
15
22.1
22.1
7
Series SYJ3000
2 Position Single [ ]: AC
G
Grommet (G), (H): SYJ3140- H -M5
M5 x 0.8 10
(A, B port)
5
10
2-ø3.2 32.2
(For mounting)
22 4
2.5
Manual override
B A
11
A
B
1
G: Approx. 300
H: Approx. 600 54.4 [56.6]
(Light/surge voltage suppressor) (Lead wire length)
41.5 [48.5]
-+
35.6
28.5
26.1
R2 P R1
13
10 10 10 M5 x 0.8
17.5 (P, R1, R2 port)
14
28
41.5 [48.5]
26.1
46 M8 x 1
28.5
52.6 [59.6] Approx. 300
(Lead wire length)
64.3 [66.5]
54.5 [56.7]
63.4
56
49.5
R2
R2
R2
10 10
10 10
10 10
28
28
28
P
P
14
14
14
R1
R1
R1
5 5 5
28.5 28.5 28.5
35.6 35.6 35.6
8
Series SYJ3000
2 Position Double [ ]: AC
G
Grommet (G), (H): SYJ3240- -M5 H
M5 x 0.8 10
(A, B port)
5
10
2-ø3.2
(For mounting) 22
2.5
Manual override
B A
11
A
B
34.4
G: Approx. 300
H: Approx. 600 78.8 [83.2]
(Light/surge voltage suppressor) (Lead wire length)
41.5 [48.5]
-+
35.6
26.1
R2 P R1
13
10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)
28
41.5 [48.5]
26.1
46 M8 x 1
28.5
52.6 [59.6] Approx. 300
(Lead wire length)
98.6[103]
79 [83.4]
R2
R2
R2
10 10
10 10
10 10
96.8
28
28
69
28
82
P
P
14
14
14
R1
R1
R1
5 5 5
9
Series SYJ3000
M5 x 0.8
10 (A, B port)
5
10
2-ø3.2 32 15.3
(For mounting)
22 3
2.5
Manual override
B A
11
A
B
37.5 [39.7]
G: Approx. 300
H: Approx. 600 91.7 [96.1]
(Lead wire length)
(Light/surge voltage suppressor)
41.5 [48.5]
-+
35.6
26.1
R2 P R1
13
10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)
28
41.5 [48.5]
26.1
46 M8 x 1
28.5
52.6 [59.6] Approx. 300
(Lead wire length)
55.8
49.3
111.5 [115.9]
R2
R2
R2
91.9 [96.3]
10 10
10 10
10 10
28
28
28
109.7
P
P
14
14
14
R1
R1
R1
37.6 [39.8]
5 5 5
47.4 [49.6]
32.6
39.1
46.5
10
Series SYJ3000
Manifold Specifications
Manifold Standard
Manifold Specifications
Model Type 20 Type 31, S31 Type 32, S32 Type 41, S41 Type 46, S46
Flow Characteristics
Flow characteristics
Port size Effective
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv (mm2)
Port Port [dm /(s·bar)]
3 [dm /(s·bar)]
3
Body ported
Type SS5YJ3-20 SYJ32 M5 x 0.8 M3 x 0.5 – – – – – – 0.9
for internal pilot
31
Type SS5YJ3- S31 SYJ33 M5 x 0.8 M3 x 0.5 – – – – – – 0.9
Type SS5YJ3-32-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 –
Type SS5YJ3-32-C4 C4 0.25 0.18 0.059 0.30 0.27 0.075 –
SYJ33 1/8
Type SS5YJ3-S32-M5 M5 x 0.8 0.25 0.26 0.060 0.29 0.15 0.062 –
Type SS5YJ3-S32-C4 C4 0.24 0.21 0.057 0.27 0.18 0.062 –
Base mounted Type SS5YJ3-41-M5 M5 x 0.8 0.32 0.25 0.081 0.33 0.19 0.079 –
for internal pilot Type SS5YJ3-41-C4 C4 0.32 0.28 0.079 0.35 0.24 0.084 –
SYJ34 1/8
Type SS5YJ3-S41-M5 M5 x 0.8 0.33 0.29 0.082 0.34 0.17 0.081 –
Type SS5YJ3-S41-C4 C4 0.32 0.27 0.079 0.34 0.24 0.084 –
Type SS5YJ3-46-M5 M5 x 0.8 0.20 0.25 0.048 0.10 0.12 0.024 –
Type SS5YJ3-46-C4 1/8 C4 0.21 0.27 0.050 0.21 0.13 0.047 –
SYJ34
Type SS5YJ3-S46-M5 M5 x 0.8 M5 x 0.8 0.20 0.25 0.048 0.19 0.16 0.024 –
Type SS5YJ3-S46-C4 C4 0.22 0.34 0.057 0.10 0.090 0.024 –
Note) Value at manifold base mounted, 2 position single operating
11
Series SYJ3000
Flow Characteristics
Type 21P
Flow characteristics
Port size Effective
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv (mm2)
Port Port [dm /(s·bar)]
3 [dm /(s·bar)]
3
Body ported
Type SS5YJ3-21P SYJ323 1/8 M3 x 0.5 – – – – – – 0.9
for internal pilot
Base mounted Type SS5YJ3-32P-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 –
for internal pilot Type SS5YJ3-32P-C4
SYJ333 1/8
C4 0.25 0.18 0.059 0.3 0.27 0.075 –
Note) Value at manifold base mounted, 2 position single operating
12
Series SYJ3000
Common SUP/Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
R –+
R : :
A
P R port –+
B
P
R port Single solenoid coil is on
B
M5 x 0.8 A, B port A S 20 20 stations
M5 x 0.8 same side as the A,B port.
A, B port M3 x 0.5 Applicable solenoid valve
P port P port
M3 x 0.5 SYJ330-
M5 x 0.8
M5 x 0.8 SYJ333-
Type 32 (4 Port/Base mounted) How to Order Applicable blanking plate
assembly
Type 32 Type S32 SS5YJ3– 32– 05 – M5 SYJ3000-21-2A
( Single
same side as the A,B port. )
solenoid coil is on
Valve mounting direction Stations
Applicable blanking plate
R port assembly
1/8 P port Single solenoid coil is on 02 2 stations SYJ3000-21-2A
Nil opposite side as the A,B port.
1/8 : :
Single solenoid coil is on
–+
S 20 20 stations
P, R port
–+
–+ –+
–+ same side as the A,B port.
–+
P
–+
R
R
A, B port size thread type
A
P port B
B
1/8
A
R port M5 M5 x 0.8 Nil Rc
A, B port 1/8 C4 One-touch fitting for ø4 F G
A, B port
M5 x 0.8, C4 M5 x 0.8, C4 N3 One-touch fitting for ø5/32" N NPT
T NPTF
Common SUP/Individual EXH Note) For more than10 stations, supply air to both sides of P port.
P M5 x 0.8 –+
–+
same side as the A,B port.
P
A
A, B port B A, B port size Nil Rc
B A
A, B port P port M5 x 0.8, C4 M5 M5 x 0.8 F G
M5 x 0.8, C4 1/8
P port C4 One-touch fitting for ø4 N NPT
1/8 N3 One-touch fitting for ø5/32" T NPTF
13
Series SYJ3000
Common SUP/Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Applicable solenoid valve
Type 21P How to Order
Refer to page 12.
A, B port
M3 x 0.5 SS5YJ3–21P– 07 – Applicable connector
P, R port assembly
Stations thread type Refer to page 12.
04 4 stations Nil Rc Applicable blanking
: : 00F G plate assembly
P port 12 12 stations 00N NPT SYJ3000-21-3A
R port (With dust cap)
1/8 1/8 00T NPTF
Mixed Installation of the SYJ300 and the SYJ3000 Valves on the Same Manifold
Series SYJ300 valves can be mounted on the
manifolds for Series SYJ3000.
q SS5YJ3-20, SS5YJ3-21P (SYJ300 3 port valve)
The 3 port valve can be used by simply sealing off
the unused “R” port with rubber plug SYJ3000-33-
1.
Applicable solenoid valves:
Series SYJ312, SYJ312M, SYJ322, SYJ322M (SYJ300 3 port valve)
w SS5YJ3-31, -S31, SS5YJ3-32, -S32,
SS5YJ3-46, -S46, SS5YJ3-32P
Plug (SYJ3000-33-1) Plug (SYJ3000-33-1)
The 3 port valve can be used without modifica-
tion. The A port of the valve will flow out of the B Seal the unused “R” port Seal the unused “R” port
port of the manifold. at the end the manifold. at the end the manifold.
Applicable solenoid valves:
Series SYJ314, SYJ314M, SYJ324, SYJ324M
e SS5YJ3-41, -S41
The 3 port valve can be used on the 4 port
manifold by simply sealing off the unused “R” port
with rubber plug SYJ3000-33-1. The A port of the –+
–+
valve will flow out of the B port of the manifold.
Applicable solenoid valves:
R
P
A
B
Caution
Mounting screw tightening torques
Type SS5YJ3-20 Type SS5YJ3-41
M1.7: 0.12 N·m
Use caution to the assembly orientation for A port of the 3 port valve flows out of the manifold B port.
solenoid valves, gasket, and optional parts.
14
Series SYJ3000
Combination of Blanking Plate Assembly and Manifold Base Difference between SYJ33 03 and SYJ34 03
Blanking plate assembly Blanking plate assembly SYJ330, 333 SYJ340, 343
SYJ3000-21-1A SYJ3000-21-2A (4 port) (5 port)
Round head combination screw
Blanking plate
A Mark A Mark
Manifold Manifold
gasket gasket
Blanking plate
Blanking plate A Mark
A Mark
Manifold
Manifold
gasket
gasket
Caution
Mounting screw tightening torques
M1.7: 0.12 N·m
Applicable manifold base Applicable manifold base Use caution to the assembly orientation for
Type SS5YJ3-32P Type SS5YJ3-21P solenoid valves, gasket, and optional parts.
Manifold base Manifold base
15
Series SYJ3000
Approx. 300
(Lead wire length)
Grommet (G)
(Pitch)
P = 10.5 12.5
Manual override
4 5
3.7
15.8
1.5
91.7 [96.1]
78.8 [83.2]
7 10
R
R
A A A A A
14
19.5
11 10
30.7
31.5
29
52.9 [55.1]
53.7 [55.9]
B B B B B
R
R
2-ø3.5 M5 x 0.8
(For mounting) (P, R port)
M3 x 0.5
(A, B port)
L2 3.5
L1
(Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
42 [49]
26.6
13.5
42 [49]
26.6
M8 x 1
Approx. 300 53.1 [60.1]
(Lead wire length)
1.5
1.5
1.5
111.5 [115.9]
91.9 [96.3]
109.7
98.6[103]
79 [83.4]
94.9
96.8
82
53 [55.2]
62.8 [65]
54.5
61.9
0.8
0.8
0.8
0.8
29
46.5
16
Series SYJ3000
2-ø3.5
(For mounting) Manual override
M5 x 0.8
5.2
7.5
52.2 [54.4]
51.4 [53.6]
17.3
(P, R port)
3
91.7 [96.1]
78.8 [83.2]
78.8 [83.2]
13.5
A A A A A
B B B B B
91.7 [96.1]
R
R
R
29.2
R
30
29.2
25
12
25
51.4 [53.6]
52.2 [54.4]
30
3 13.5
B B B B B
P
P
P
P
A A A A A
17.3
7.5
5.2
-+ -+ -+ -+ -+ -+ -+
28.1
A A B B
15
15
12
12
B B A A
3
1 (Pitch) (Pitch) 1
13.5 P = 10.5 M3 x 0.5 M3 x 0.5 P = 10.5 14.5
(A, B port) (A, B port)
0.8
0.8
0.8
61.3 [63.5]
51.5 [53.7]
60.4
53
98.6[103]
111.5 [115.9]
79 [83.4]
91.9 [96.3]
96.8
82
109.7
94.9
28
43.4 [47.3]
Approx. 300
17
Series SYJ3000
Type 32 Manifold: Side Ported/SS5YJ3-32- Stations -M5, C4
N3 [ ]: AC
Approx. 300
(Lead wire length)
Grommet (G) L1 For C4
N3 (Built-in one-touch fitting)
Manual override
For M5 4 L2 10
2-ø4.5
(For mounting)
36.5
17
10 1/8
54.2 [56.4]
53.4 [55.6]
(P, R port)
78.8 [83.2]
91.7 [96.1]
31.5
3.2 31.2
R
(4.4)
12.5
B B B B B
32
17
1 16
P
P
A A A A A
7.5
15.3
(Station 1) (Station n)
L1
(Pitch) 4.5 L2
15.5 P = 10.5 (Light/surge voltage suppressor)
15.5
(Station 1) (Station n) -+ -+
20
48.5 [55.5]
15
5
B B
-+ -+
(Pitch)
A 16 P = 10.5 (A, B port)
20
A
15
B B
Applicable tubing O.D.: ø4, ø5/32"
1
5
(Pitch) M5 x 0.8
16.5 P = 10.5
(A, B port)
0.8
35.5
0.8
0.8
63.3 [65.5]
53.5 [55.7]
Approx. 300 111.5 [115.9]
62.4
98.6[103]
79 [83.4]
91.9 [96.3]
55
96.8
109.7
82
94.9
1
(Lead wire length)
10
15.5
91.7 [96.1]
34.2 0.2
78.8 [83.2]
36.5
17
57.2 [59.4]
R
R
A A A A A
31.5
56.4 [58.6]
35
B B B B B
P
P
(4.4)
12.5
-+ -+ -+ -+ -+
B
20
B
15
5
A A
B B
20
5
15
1
M5 x 0.8 (Pitch) A A
18
Series SYJ3000
Type 41 Manifold: Side Ported/SS5YJ3-41- Stations -M5, C4
N3 [ ]: AC
Approx. 300
(Lead wire length)
Grommet (G) (Pitch)
For C4
N3 (Built-in one-touch fitting)
For M5 16 P = 10.5 1/8
10 (P port)
Manual override
1/8
36.4
61.7 [63.9] 10
60.9 [63.1]
10 (P port)
21.4
78.8 [83.2]
91.7 [96.1]
R
B B B B B
39.5
38.7
36.5
18
4.3
21.5
R
(4.4)
P
A A A A A
3
11.5
7.8
20
48.5 [55.5]
15
B B
5
-+ -+
2 One-touch fitting
33.1
(Pitch)
A A
17 P = 10.5 (A, B port)
20
15
5
B B
Applicable tubing O.D.: ø4, ø5/32"
2 (Pitch) M5 x 0.8
17 P = 10.5
(A, B port)
35.5
0.8
0.8
0.8
70.8 [73]
61 [63.2]
69.9
111.5 [115.9]
98.6[103]
62.5
79 [83.4]
91.9 [96.3]
96.8
109.7
82
94.9
(Lead wire length)
Approx. 300
C4
Type S41 Manifold: Side Ported Single solenoid coil is on
same side as the A,B port. /SS5YJ3-S41- Stations -M5, N3
(Pitch)
For M5 P = 10.5 16 For C4
N3 (Built-in one-touch fitting)
Manual override
32.2 2.2
33 14.3
91.7 [96.1]
78.8 [83.2]
1/8
10
55.2 [57.4]
54.4 [56.6]
(P port)
R
A A A A A
33.5
36.5
P
B B B B B
R
36.4
21.4
2-ø4.5
(4.4)
L2 4 (For mounting)
L1
(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
-+ -+ -+ -+ -+
B B
20
15
B B
20
A A
15
A A
5
2 (Pitch) 2
M5 x 0.8 (Pitch) One-touch fitting
P = 10.5 15 P = 10.5 15
(A, B port) (A, B port)
Applicable tubing O.D.: ø4, ø5/32"
19
Series SYJ3000
Type 46 Manifold: Side Ported/SS5YJ3-46- Stations -M5, C4
N3 [ ]: AC
Approx. 300
(Lead wire length)
Grommet (G)
(Pitch)
For C4
N3 (Built-in one-touch fitting)
For M5 14.5 P = 10.5 1/8
Manual override
10 (P port)
1/8
59.9 [62.1]
60.7 [62.9]
10
34.9
(P port)
78.8 [83.2]
18.9
91.7 [96.1]
B B B B B
38.5
37.7
35
3.3
P
19
(4.4)
A A A A A
10
8.8
2-ø4.5
4 L2 (For mounting) (Station 1) (Station n)
L1 (Light/surge voltage suppressor)
(Station 1) (Station n)
-+ -+
(Light/surge voltage suppressor)
48.5 [55.5]
A A
20
15
-+ -+
B B
5
33.1
35.5
0.8
0.8
0.8
69.8 [72]
60 [62.2]
68.9
Approx. 300 111.5 [115.9]
98.6[103]
61.5
79 [83.4]
91.9 [96.3]
96.8
109.7
82
94.9
(Lead wire length)
C4
Type S46 Manifold: Side Ported Single solenoid coil is on
same side as the A,B port. /SS5YJ3-S46- Stations -M5, N3
(Pitch)
For M5 P = 10.5 14.5 For C4
N3 (Built-in one-touch fitting)
Manual override
32.5 14.8
25 0.5
31.7 2.7
91.9 [96.3]
78.8 [83.2]
1/8
A A A A A
10
53.9 [56.1]
(P port)
54.7 [56.9]
25
35
P
B B B B B
34.9
18.9
2-ø4.5
(4.4)
L2 4 (For mounting)
L1
(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)
-+ -+ -+ -+ -+
(Light/surge voltage suppressor) -+ -+ -+ -+ -+
B B
20
B B
20
15
15
A A
5
A A
5
20
Series SYJ3000
L1
L2 4
Manual override
-+ -+ -+
M3 x 0.5 -+
(A, B port) 10
2 2
29.2 5.2
111.5 [115.9]
30 17.3
7.5
7 8.5
16 3
98.6[103]
A
P
P
31.5
61.3 [63.5]
62.1 [64.3]
17
45.5
B
65.3
R
2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+
Triangle mark
(Pitch) 1/8
P = 12.5 18.5 (P, R port)
(Station n) (Station 1)
(Light/surge voltage suppressor)
48.5 [55.5]
25.6
5.8
20
28.5
A A
(A, B port) 1
Applicable tubing O.D.: ø4, ø5/32"
B B 5
15
20
A A
L1
L2 4
Manual override
-+ -+ -+
-+
10 10
3.2
32 15.3
111.5 [115.9]
7.5
(4.4)
12.4
31.2 1
98.6[103]
16
A A A A A A
P
P
31.5
63.3 [65.5]
17
64.1 [66.3]
36.4
B B B B B B
R
R
65.3
17
50.4
70.2
2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+
Triangle mark
(Pitch) 1/8
P = 12.5 18.5 (P, R port)
1/8
(Station n) (Station 1) (P, R port)
(Light/surge voltage suppressor)
Applicable connector: 26 pins MIL type
With strain relief
48.5 [55.5]
(Conforming to MIL-C-83503)
25.6
5.8
20
21
22
Rubber Seal
5 Port Solenoid Valve
Fluid Air
2 position single 0.15 to 0.7
Operating pressure range
MPa 2 position double 0.1 to 0.7
3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing. Refer to back page 3.)
Response time (ms) Note 1) 2 position single, double 25 or less
(at 0.5 MPa) 3 position 40 or less
Max. operating frequency 2 position single, double 5
(Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Individual exhaust for the pilot valve, Common exhaust for the pilot and main valve
Body ported Lubrication Not required
Mounting orientation Unrestricted
Shock/Vibration resistance (m/s2) Note 2) 150/30
Enclosure Dust proof (∗ DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main valve and
armature in both energized and de-energized states every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle
directions of the main valve when pilot signal is ON and OFF. (Value in the initial state)
Solenoid Specifications
Flow Characteristics/Weight
Port size Flow characteristics Note 1) Weight (g) Note 2, 3)
Valve model Type of actuation 1, 5, 3 4, 2 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) L/M plug DIN M8
(P, EA, EB) (A, B) C [dm3/(s·bar)] Grommet
b Cv C [dm3/(s·bar)] b Cv connector terminal connector
Single 46 47 68 51
2 position 0.47 0.41 0.13 0.47 0.41 0.13
Double 64 66 108 74
SYJ520--M5 Closed center M5 x 0.8 M5 x 0.8 0.49 0.44 0.13 0.44 0.40 0.12
3 position Exhaust center 0.46 0.37 0.12 0.47 [0.39] 0.43 [0.35] 0.13 [0.10] 75 77 119 85
Pressure center 0.49 [0.39] 0.51 [0.38] 0.14 [0.10] 0.45 0.42 0.12
Single 53 54 75 58
Body ported
Base Mounted
Bore size
Series CJ2 Series CM2 Series MB/CA2
Average speed Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series Load rate: 50%
(mm/s) Load rate: 50% Load rate: 50%
Stroke 60 mm Stroke 300 mm Stroke 500 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
800
700 Perpendicular, upward actuation
600
500 Horizontal actuation
SYJ5140-01 400
300
200
100
0
∗ Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
∗ Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
∗ Load factor: ( (Load weight x 9.8) /Theoretical force) x 100%
Conditions
Body ported Series CJ2 Series CM2 Series MB/CA2 Base mounted Series CJ2 Series CM2 Series MB/CA2
Tubing bore x Length ø4 x 1 m ø6 x 1 m ø8 x 1 m Tubing bore x Length ø4 x 1 m ø6 x 1 m
SYJ5120-M5 Speed controller AS1301F-04 AS3301F-06 AS3301F-08 SYJ5140-01 Speed controller AS2301F-04 AS3001F-06
Silencer AN120-M5 AN110-01 Silencer AN101-01 AN101-01
24
Series SYJ5000
How to Order
Light/surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Type of actuation Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
1 2 position single solenoid S With surge voltage suppresor S With surge voltage suppressor (Non-polar type)
2 2 position double solenoid Z With light/surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type)
3 3 position closed center R With surge voltage suppressor (Non-polar type) ∗ DOZ is not available.
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
5 3 position pressure center ∗ For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit. Bracket
∗ For type “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the "Z" type. Nil: Without bracket
F: With bracket
Rated voltage
DC AC (50/60 Hz)
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC [115 VAC] M5 M5 x 0.8
S 5 VDC 4 220 VAC [230 VAC] C4 One-touch fitting for ø4
R 3 VDC ∗ For type W, C6 One-touch fitting for ø6
∗ DC specifications of type DC voltage is N3 One-touch fitting for ø5/32"
D and DO is only available only available. N7 One-touch fitting for ø1/4"
with 12 and 24 VDC. Note) The mounting bracket is
(For manifold type 20) supplied unattached.
R port P, E port
(With gasket and screws)
–+ –+
H: Lead wire LN: Without LO: Without MO: Without DO: Without W: With
length 600 mm lead wire connector connector connector connector
cable Note 1)
25
Series SYJ5000
Construction
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
e qy t rw w q (A) t(B) r
(A) (B)
4 2 4 2
i
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
i
5 1 3
t q rw
(R1) (P) (R2)
(A) (B)
3 position exhaust center
(A) (B) 4 2
4 2
5 1 3
(R1) (P) (R2)
26
Series SYJ5000
V100-49-1-
V115 5 D 1
Cable length
300 mm
Light/surge voltage suppressor 2 500 mm
Rated voltage
Nil Without light/surge voltage suppressor 3 1000 mm
5 24 VDC
S With surge voltage suppressor (Non-polar type) 4 2000 mm
6 12 VDC
Z With light/surge voltage suppressor (Non-polar type) 7 5000 mm
1 100 VAC 50/60 Hz
∗ DOZ is not available.
2 200 VAC 50/60 Hz ∗ For AC voltage valves there is no “S” option.
110 VAC 50/60 Hz It is already built-in to the rectifier circuit.
3
[115 VAC 50/60 Hz]
220 VAC 50/60 Hz Electrical entry
4 D With connector
[230 VAC 50/60 Hz] DIN
∗ DC specifications of DO terminal Without connector
type D and DO is Note) Do not replace V111 (G, H, L, M,
only available with W) to V115 (DIN terminal) and
12 and 24 VDC. vice versa when replacing pilot
∗ Power saving circuit valve assembly only.
is not available in
the case of D or DO
type.
27
Series SYJ5000
2 Position Single [ ]: AC
37
G: Approx. 300
63.1 [65.3] H: Approx. 600 2-ø3.5 30 3.5
(Lead wire length) (For mounting)
41
19.5
18
25
-+
11
19.7
5
A B
35.1 [42.1]
M5 x 0.8 10 Manual override
(A, B port) 19 2-ø2.6
(For monifold mounting)
63.1 [65.3]
2-M3 x 0.5 (Light/surge voltage suppressor)
(Mounting screw)
-+
18
23
20
2.3
(Bracket)
28.1 [35.1]
12.7
2.5
10.6 11 2-ø2.6
3.5 4
Built-in one-touch fitting:
(For mounting)
SYJ5120- GH - C4, N3
C6, N7 (-F)
19.5
3.5
A B
R1 P
16
15
R2 10.6
(3.2) One-touch fitting
M5 x 0.8 21 ø1.4 (A, B port)
(P, R1, R2 port) (PE port) Applicable tubing O.D. : ø4, ø5/32"
: ø6, ø1/4"
32.3
(2.3)
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ5120-L-M5(-F) SYJ5120-M-M5(-F) SYJ5120-D-M5(-F) SYJ5120-WO-M5(-F)
Approx. 300
(Lead wire length)
63.2 [65.4]
82.1
83
72.1
58.2
64.7
3 3 3 3
42.2
19.5
19.5
19.5
19.5
11
11
11
11
(2.3)
(2.3)
20 2-ø2.6
(2.3)
28
Series SYJ5000
2 Position Double [ ]: AC
G
Grommet (G), (H): SYJ5220- H -M5 Built-in one-touch fitting:
SYJ5220- GH - C4, N3
C6, N7
G: Approx. 300
87.2 [91.6] H : Approx. 600
43 (Lead wire length)
3.5
11
5
A B A B
(3.2)
One-touch fitting
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D. : ø4, ø5/32"
: ø6, ø1/4"
32.3
-+
23
20
3
28.1 [35.1]
11 2-ø2.6
12.7
(For mounting)
R1 P
15
R2
M5 x 0.8 21 ø1.4
(P, R1, R2 port) (PE port)
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ5220-L-M5 SYJ5220-M-M5 SYJ5220-D-M5 SYJ5220-WO-M5
Approx. 300
(Lead wire length)
20 20 20 20
107 [111.4]
3
87.4 [91.8]
3 3 3
105.2
125.2
90.4
77.4
45.4
127
11
11
11
11
23
2-ø2.6 2-ø2.6 2-ø2.6
(For mounting) (For mounting) (For mounting)
23
23
23
27
2-ø2.6
(For mounting)
29
Series SYJ5000
G: Approx. 300
103.2 [107.6] H: Approx. 600
44.2 [46.4] (Lead wire length)
36.9 22.1 44.2 [46.4]
3.5
11
5
A B A B
(3.2)
One-touch fitting
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D. : ø4, ø5/32"
: ø6, ø1/4"
32.3
-+
23
20
3
R1 P
15
R2
M5 x 0.8 21 ø1.4
(P, R1, R2 port) (PE port)
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SYJ5 4 20-L-M5 SYJ5 4 20-M-M5 SYJ5 4 20-D-M5 SYJ5 4 20-WO-M5
5 5 5 5
(Lead wire length)
Approx. 300
44.3 [46.5]
64.1
63.2
53.2
45.8
39.3
20 20 20 20
23.3
3 3 3 3
103.4 [107.8]
123 [127.4]
11
11
11
141.2
121.2
143
11
38.1
23 2-ø2.6 23 2-ø2.6 23 23
54.1
60.6
27
30
Series SYJ5000
2 Position Single [ ]: AC
G
Grommet (G), (H): SYJ5140- H -01 Built-in speed controller:
SYJ5150- H -01
G
Max. 13.5
1/8 19.4 10.3
17 11.5
(A, B port)
8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24 With interface regulator
B
R P
69.6 [76.6]
50.1 [57.1]
-+
54.2
45
34.7
8.5
31.5
21.5
15 17 17 43.9
24 1/8 45.5
(P, R port)
32
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ5140-L-01 SYJ5140-M-01 SYJ5140-D-01 SYJ5140-WO-01
ø3.5 to ø7
82.9
Max. 10
63.7 [65.9]
83.5
82.6
65.2
72.6
58.7
45.5
45.5
45.5
45.5
17 17
17 17
17 17
17 17
42.7
0.5
0.5
0.5
6 6 6 6
0.5
31
Series SYJ5000
2 Position Double [ ]: AC
1/8 17 11.5
(A, B port)
Max. 13.5
8.5
19.4 10.3
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24
B
R P
41.5 1.5
G: Approx. 300 23.6 [25.8]
H: Approx. 600 87.2 [91.6] With interface regulator
(Lead wire length)
107.5 [109.7]
(Light/surge voltage suppressor)
69.6 [76.6]
50.1 [57.1]
-+
54.2
45
34.7
31.5
8.5
21.5
15 17 17 43.9
24 1/8 45.5
(P, R port)
32
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ5240-L-01 SYJ5240-M-01 SYJ5240-D-01 SYJ5240-WO-01
Applicable cable O.D.
Approx. 300
(Lead wire length)
ø3.5 to ø7
82.9
Max. 10
87.4 [91.8]
65.2
58.7
45.5
45.5
45.5
45.5
125.2
105.2
17 17
17 17
17 17
17 17
42.7
127
2.7
18.7
6 6 6 6
25.2
32.6
42.6
43.5
32
Series SYJ5000
1/8 17 11.5
Max. 13.5
(A, B port)
19.4 10.3
8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24
B
R P
42.1 16.9
G: Approx. 300
39 [41.2] With interface regulator
H: Approx. 600 103.2 [107.6]
(Lead wire length)
108.1 [110.3]
(Light/surge voltage suppressor)
69.6 [76.6]
50.1 [57.1]
-+
54.2
45
34.7
31.5
21.5
15 17 17 43.9
8.5
1/8
24 45.5
(P, R port)
32
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SYJ5 4 40-L-01 SYJ5 4 40-M-01 SYJ5 4 40-D-01 SYJ5 4 40-WO-01
5 5 5 5
Applicable cable O.D.
(Lead wire length)
ø3.5 to ø7
Approx. 300
82.9
Max. 10
45.5
45.5
45.5
43.3
17 17
17 17
17 17
17 17
141.2
121.2
143
18.1
48.9 [51.1]
6 6 6 6
34.1
40.6
58
33
Series SYJ5000
Manifold Specifications
Manifold Standard
Manifold Specifications
Flow Characteristics
Flow characteristics
Port size
1 → ω4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
Port Port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
for internal pilot
Type SS5YJ5-20 SYJ52 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
Type SS5YJ5-40 1/8 M5 x 0.8 0.55 0.35 0.15 0.64 0.26 0.16
Type SS5YJ5-41 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
Base mounted
for internal pilot
Type SS5YJ5-42-01 SYJ54 1/4 1/8 0.74 0.22 0.18 0.82 0.31 0.21
Type SS5YJ5-42-C6 1/4 C6 0.71 0.24 0.17 0.8 0.29 0.20
Type SS5YJ5-43 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
Note) Value at manifold base mounted, 2 position single operating
34
Series SYJ5000
Flow Characteristics
Flow characteristics
Port size
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
Port Port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
for internal pilot
Type SS5YJ5-20P SYJ523 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
Base mounted Type SS5YJ5-41P 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
SYJ543
for internal pilot Type SS5YJ5-43P 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
Note) Value at manifold base mounted, 2 position single operating
35
Series SYJ5000
Common SUP/Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.
1/8 Nil Rc
P
20 20 stations
A, B port
F G
M5 x 0.8 P port A, B port size N NPT
1/8 M5 M5 x 0.8 T NPTF
Applicable solenoid valve
Type 42 (5 Port/Base mounted) How to Order SYJ540-
SS5YJ5– 42– 05 – C6 SYJ543-
SYJ550-
SYJ553-
Stations
-+ 02 2 stations Applicable blanking
-+
plate assembly
B
R port : :
SYJ5000-21-4A
R
20 20 stations
P
Stations
-+
-+
02 2 stations
R R port : : P, R port
P thread type
A 1/8
A, B port 20 20 stations
B Nil Rc
C4 P port
A, B port size F G
1/8
C4 One-touch fitting for ø4 N NPT
N3 One-touch fitting for ø5/32" T NPTF
36
Series SYJ5000
A
Applicable blanking
plate assembly
B
A
P port P, R port
Number of stations
B
A
SS5YJ5–41P– 05 –M5
B
A
B
A, B port
B
A
A, B port
B
A
B
B
A
P port 03 3 stations
A, B port size Nil Rc
1/8 : :
C4 One-touch fitting for ø4 F G
R port 12 12 stations N NPT
N3 One-touch fitting for ø5/32"
1/8 T NPTF
Blanking plate
Blanking plate
Gasket Gasket
Caution
Applicable manifold base Mounting screw tightening torques
Type SS5YJ5-20 Dust cap
M2.5: 0.45 N·m
Type SS5YJ5-40 Applicable manifold base
Type SS5YJ5-41 Type SS5YJ5-20P Use caution to the assembly orientation for
Type SS5YJ5-42 Type SS5YJ5-41P
Type SS5YJ5-43P solenoid valves, gasket, and optional parts.
Type SS5YJ5-43
37
Series SYJ5000
Mix Installation of the SYJ500 and the SYJ5000 Valves on the Same Manifold Interface Regulator (P port regulation)
Use of an adapter plate makes it possible to mount Series SYJ500 on the manifold bases of Spacer type regulating valve on manifold block
series SYJ5000. can regulate the pressure to the valve
When mounting the SYJ500 valve on the SYJ5000 manifold, the SYJ500 solenoid must be posi- individually.
tioned on the same side of the manifold as a single solenoid SYJ500. (Refer to the figure below.)
For base mounted style, the A port of the 3 port valve flows out the B port of manifold base. ARBYJ5000-00-P
Round head
Adapter Plate Assembly combination
screw
SYJ500-3-2A SYJ500-3-1A
Round head
combination screw
Base mounted
A
A
Manifold gasket
Manifold gasket
10
15
P
Individual EXH spacer
38
Series SYJ5000
Grommet (G)
Approx. 300
(Lead wire length)
13.4
(DIN 14.6)
(Pitch)
2
10 18.5 (DIN 0.8)
P = 16 21
16.5 15.2
23.5
(DIN 46.8)
87.2 [91.6]
(DIN 46.2)
R
16.5 16.5
A
67.1 [69.3]
67.7 [69.9]
45.6
45
49
P
P
B
B
R
4-ø4.5 1/8
(For mounting) (P, R port)
M5 x 0.8
Manual override L2 9 (A, B port)
L1
Built-in one-touch fitting
(Station n) (Station 1)
-+ -+ -+ -+ -+
33.2
20
(3.2) 52.8
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)
Max. 10
87.4 [91.8]
141.2
121.2
106.4
143
125.2
105.2
67.2 [69.4]
90.4
127
77 [79.2]
68.7
76.1
86.1
87
0.6
0.6
35.6
0.6
0.6
33.2
53.1
0.6
0.6
39
Series SYJ5000
Grommet (G)
Approx. 300
(Lead wire length)
L1
L2 9
4-ø4.5
(For mounting)
13
36.9
16.5
A A A A A
87.2 [91.6]
33
47
P
P
44.2 [46.4]
22.1
B B B B B
R
2.5
1/8
(Pitch) (P, R port)
P = 16 21 Manual override
(Station n) (Station 1)
-+ -+ -+ -+ -+
33.2
20
M5 x 0.8
(A, B port)
12
24
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)
Max. 10
87.4 [91.8]
141.2
121.2
106.4
143
125.2
105.2
90.4
127
43.7 [45.9]
53.5 [55.7]
45.2
52.6
62.6
63.5
0.6
0.6
35.6
0.6
0.6
33.2
62.6 53.1
0.6
0.6
48.6 [55.6]
73.9
81.4
40
Series SYJ5000
Grommet (G)
Approx. 300
(Lead wire length)
L1
4.5 L2 Manual override
2-ø5.5
(For mounting)
12
60.2 [62.4]
59.6 [61.8]
(DIN 6.7) (DIN 38.7)
(DIN 22.1) (DIN 39.3)
87.2 [91.6]
103.2 [107.6]
B B B B B R
38.1
37.5
21
35
3.5 17.5
P
A A A A A
7
20.9
1/8
5.5
(P, R port)
(Pitch)
18 P = 16
-+ -+ -+
37.2
A A
18.5
24
B B
5.5
(Pitch)
23 P = 16
M5 x 0.8
(A, B port)
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
85.4
77.9
52.6 [59.6] 66.6 M8 x 1
0.6
57.1
0.6
37.2
0.6
39.6
0.6
0.6
0.6
69.5 [71.7]
59.7 [61.9]
79.5
78.6
68.6
61.2
107 [111.4]
87.4 [91.8]
103.4 [107.8]
123 [127.4]
125.2
105.2
127
90.4
141.2
121.2
106.4
143
3.5
3.5
3.5
3.5
Pg7
(Lead wire length)
Max. 10
41
Series SYJ5000
Type 42: Side Ported/SS5YJ5-42- Stations -01, C6
N7 [ ]: AC
Grommet (G) C6
For N7 (Built-in one-touch fitting)
For 01
Approx. 300
(Lead wire length)
L1 Manual override
6.5 L2
2-ø6.5
(For mounting)
17.5 17.5
65.2 [67.4]
64.6 [66.8]
(DIN 44.3)
87.2 [91.6]
103.2 [107.6]
B B B B B
43.9
43.1
0.5 42.5
24
24
44
23
P
A A A A A
10.5
10.4
( DIN 17.1)
15.9
1/4 1/4
(Pitch) (P, R port)
24.5 P = 17 (P, R port)
(Station 1) (Station n)
(Station 1) (Station n)
(Light/surge voltage suppressor) Built-in speed controller (Light/surge voltage suppressor)
Max. 13.5 56.5
61.6 [68.6]
61.6 [68.6]
-+ -+ -+ -+ -+ -+
46.2
46.2
A A A A
33
33
24.5
25
B B B B
1
8.5
8.5
(Pitch) (Pitch)
24.5 P = 17 1/8 29 P = 16 One-touch fitting
(A, B port) (A, B port)
Applicable tubing O.D.: ø6, ø1/4"
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
94.4
61.6 [68.6] 86.9
M8 x 1 66.1
0.6
0.6
75.6
46.2
0.6
0.6
48.6
0.6
0.6
74.5 [76.7]
64.7 [66.9]
84.5
83.6
107 [111.4]
73.6
87.4 [91.8]
103.4 [107.8]
66.2
123 [127.4]
125.2
105.2
90.4
127
141.2
121.2
106.4
143
Pg7
Max. 10
ø3.5 to ø7
42
Series SYJ5000
N3
Type 43: Side Ported/SS5YJ3-43- Stations - C4 [ ]: AC
Grommet (G)
Approx. 300
(Lead wire length)
L1
4.5 L2 Manual override
2-ø5.5
(For mounting)
12 1/8
62.6 [64.8]
(P, R port)
62 [64.2]
(DIN 41.7)
87.2 [91.6]
103.2 [107.6]
R
B B B B B
40.5
39.9
17.5
36.9
1.1 20.2
P
A A A A A
11.4
3.1
(4.4)
(DIN 19.7)
(Pitch)
18 P = 16
18.5
-+ -+ -+
37.2
A A
24
18
B B
6
(Pitch)
22.3 P = 16 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
85.4
52.6 [59.6] 77.9
66.6 M8 x 1 57.1
0.6
0.6
37.2
39.6
0.6
0.6
0.6
0.6
72 [74.2]
62.2 [64.4]
81.1
82
63.7
71.1
107 [111.4]
87.4 [91.8]
103.4 [107.8]
123 [127.4]
125.2
90.4
127
141.2
106.4
105.2
143
121.2
1
Pg7
Max. 10
ø3.5 to ø7
43
Series SYJ5000
C4 N3
Manual override For C6 N7 (Built-in one-touch fitting)
L1
M5 x 0.8 L2 9
(A, B port) 4-ø4.5
-+
(For mounting)
13.4
-+ -+
2.5 2.5
15.2
12.5
2
123 [127.4]
107 [111.4]
10 18.5
23.5
R
R
One-touch fitting ø6, ø1/4"
16.516.5
A
A
45.6
(A, B port)
77.6 [79.8]
45
49
77 [79.2]
P
65
Applicable tubing O.D.:
82.8
B
16.5
R
-+ -+ -+ -+ -+
Triangle mark
1/8 (3.2) 52.8
(Pitch)
P = 17.5 21 (P, R port)
(Station n) (Station 1)
(Light/surge voltage suppressor)
48.6 [55.6]
25.1
5.8
20
P = 17.5 26
(A, B port)
18.5
-+ -+
5.5
3.5
38.1 20.9
12
123 [127.4]
7
107 [111.4]
17.5
A A A A A
5.5
37.5
69.5 [71.7]
70.1 [72.3]
21
35
51
Max. 13.5
68.8
B B B B B
-+ -+ -+ -+ -+
(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6 [59.6]
7.8
29.1
24
44
Series SYJ5000
SS5YJ5-43P- Stations - N3
C4
6
Applicable tubing O.D.:
18
ø4, ø5/32"
-+ -+
(4.4)
12
11.4
3.1
40.5 18.5
39.9 1.1
123 [127.4]
107 [111.4]
20.2
A A A A A
5.5
36.9
17.5
71.9 [74.1]
72.5 [74.7]
52.9
Max. 13.5
70.7
B B B B B
-+ -+ -+ -+ -+
(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6 [59.6]
7.8
29.1
24
45
46
Rubber Seal
5 Port Solenoid Valve
Fluid Air
2 position single 0.15 to 0.7
Operating pressure range
2 position double 0.1 to 0.7
MPa
3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing. Refer to back page 3.)
Response time (ms) Note 1) 2 position single, double 30 or less
(at 0.5 MPa) 3 position 60 or less
Max. operating frequency 2 position single, double 5
(Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Body ported Pilot exhaust method Individual exhaust for the pilot valve, Common exhaust for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
Shock/Vibration resistance (m/s2) Note 2) 150/30
Enclosure Dust proof (∗ DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage,
without surge suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized
states every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test
was performed to axis and right angle directions of the main valve and
armature when pilot signal is ON and OFF. (Value in the initial state)
Base mounted
Solenoid Specifications
JIS Symbol
Body ported Base mounted
2 position single 2 position single solenoid Grommet (G), (H)
(A) (B) (B) (A) L plug connector (L)
4 2 2 4 Electrical entry M plug connector (M)
DIN terminal (D)
5 1 3 3 1 5 M8 connector (W)
(R1) (P) (R2) (R2) (P) (R1)
G, H, L, M, W D
2 position double 2 position double solenoid DC 24, 12, 6, 5, 3 24, 12
Coil rated voltage (V)
(A) (B) (B) (A) AC 50/60 Hz 100, 110, 200, 220
2 4
±10% of rated voltage ∗
4 2
Allowable voltage fluctuation
Standard 0.35 {With light: 0.4 (DIN terminal with light: 0.45)}
5 1 3 3 1 5 Power consumption (W) DC
(R1) (P) (R2) (R2) (P) (R1) With power saving circuit 0.1 (With light only)
100 V 0.78 (With light: 0.81) 0.78 (With light: 0.87)
3 position closed center 3 position closed center
110 V 0.86 (With light: 0.89) 0.86 (With light: 0.97)
(A) (B) (B) (A)
4 2 2 4 ∗ [115 V] [0.94 (With light: 0.97)] [0.94 (With light: 1.07)]
Apparent power VA AC
200 V 1.18 (With light: 1.22) 1.15 (With light: 1.30)
5 1 3 3 1 5 220 V 1.30 (With light: 1.34) 1.27 (With light: 1.46)
(R1) (P) (R2) (R2) (P) (R1) [230 V] [1.42 (With light: 1.46)] [1.39 (With light: 1.60)]
3 position exhaust center 3 position exhaust center Surge voltage suppressor Diode (DIN terminal, Varistor when non-polar types)
(A) (B) (B) (A) Indicator light LED (Neon light when AC with DIN terminal)
4 2 2 4
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
5 1 3 3 1 5 ∗ S, Z and T type (with power saving circuit) should be used within the following allowable voltage fluctuation
(R1) (P) (R2) (R2) (P) (R1) range due to a voltage drop caused by the internal circuit.
S and Z type: 24 VDC: –7% to +10%, 12 VDC: –4% to +10%
3 position pressure center 3 position pressure center T type: 24 VDC: –8% to +10%, 12 VDC: –6% to +10%
(A) (B) (B) (A)
4 2 2 4
5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1)
Made to Order
(For details, refer to pages 79 through to 80.)
47
Series SYJ7000
Flow Characteristics/Weight
3 position Exhaust center 1.2 0.48 0.35 3.4 [1.3] 0.36[0.57] 0.86 [0.41] 188 (108) 190 (110) 232 (152) 198 (118)
Pressure center 3.3 [0.85] 0.43 [0.54] 0.78 [0.25] 2.1 0.45 0.56
Single 165 (85) 166 (86) 187 (107) 170 (90)
2 position 2.3 0.41 0.61 2.9 0.35 0.74
Double 178 (98) 180 (100) 222 (142) 188 (108)
SYJ740--02 Closed center 1/4 1/4 1.9 0.46 0.50 2.2 0.44 0.60
3 position Exhaust center 1.3 0.45 0.35 3.7 [1.4] 0.27[0.56] 0.87 [0.43] 188 (108) 190 (110) 232 (152) 198 (118)
Pressure center 3.6 [0.83] 0.23 [0.55] 0.84 [0.25] 2.1 0.47 0.58
Note 1) [ ]: denotes the normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate.
Note 3) For DC voltages. For AC voltages add 3 g to the weight of the single solenoid and 6 g to the weight of the double solenoid and 3 position types.
Base Mounted
Bore size
Series CJ2 Series MB/CM2 Series MB/CA2
Average speed Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series Load rate: 50%
(mm/s) Load rate: 50% Load rate: 50%
Stroke 60 mm Stroke 300 mm Stroke 500 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
800
700 Perpendicular, upward actuation
600
500 Horizontal actuation
SYJ7140-02 400
300
200
100
0
∗ Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
∗ Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
∗ Load factor: ( (Load weight x 9.8) /Theoretical force) x 100%
Conditions
Body ported Series CJ2 Series CM2 Series MB/CA2 Base mounted Series CJ2 Series CM2 Series MB/CA2
Tubing bore x Length ø6 x 1 m ø12 x 1 m Tubing bore x Length ø6 x 1 m
SYJ7120-01 Speed controller AS2301F-06 AS3301F-06 AS4001F-12 SYJ7140-02 Speed controller AS1301F-06 AS3001F-06
Silencer AN110-01 AN200-02 Silencer AN110-01 AN200-02 AN3301F-06
48
Series SYJ7000
How to Order
Light/surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Type of actuation Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
1 2 position single solenoid S With surge voltage suppresor S With surge voltage suppressor (Non-polar type)
2 2 position double solenoid Z With light/surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type)
3 3 position closed center R With surge voltage suppressor (Non-polar type) ∗ DOZ is not available. Bracket
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there
5 3 position pressure center ∗ For AC voltage valves there is no “S” option. is no “S” option. It is already Nil: Without bracket
built-in to the rectifier circuit. F: With bracket
It is already built-in to the rectifier circuit.
∗ For type “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the "Z" type.
Thread type
Nil Rc
F G
Rated voltage
N NPT
DC AC (50/60 Hz)
T NPTF
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC [115 VAC] 01 1/8 Note) Do not remove the
S 5 VDC 4 220 VAC [230 VAC] C6 One-touch fitting for ø6 factory installed
R 3 VDC ∗ For type W, DC bracket from models
C8 One-touch fitting for ø8
with the bracket
∗ DC specifications of type voltage is only N7 One-touch fitting for ø1/4"
available. option. Removal of the
D and DO is only available N9 One-touch fitting for ø5/16" bracket will cause the
(For manifold type 20, 21) with 12 and 24 VDC.
valve to leak. Brackets
cannot be retrofitted.
D: Push-turn locking
slotted type
R port P, E port
24, 12, 6, 5, 3 VDC 24,12 VDC 24, 12, 01: 1/8 With sub-plate
Note)
H: Lead wire LN: Without LO: Without MO: Without DO: Without W: With
length 600 mm lead wire connector connector connector connector
cable Note 1)
Note 1) Enter the cable
length symbols in
. Please be sure
-+
to fill in the blank Note) R1, R2 port:
-+
49
Series SYJ7000
Construction
(A)(B) (A) (B)
2 position single 4 2 2 position double 4 2
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
e yq trw w q t r
(A) (B) (A) (B)
4 2 4 2
i i
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
u
3 position closed center/exhaust center/pressure center
3 position closed center
(A) (B)
4 2
5 1 3
(R1) (P) (R2)
t q rw
3 position exhaust center (A) (B)
(A) (B) 4 2
4 2
5 1 3
(R1) (P) (R2)
3 position pressure center
(A) (B)
4 2 i
5 1 3 5 1 3 (This figure shows a closed center type.)
(R1) (P) (R2) (R1) (P) (R2)
V111 5 G V115 5 D
Coil specifications Light/surge voltage suppressor Rated voltage
Nil Standard Nil Without light/surge voltage suppressor 5 24 VDC
With power saving circuit 6 12 VDC
S With surge voltage suppresor
T 1 100 VAC 50/60 Hz
(24, 12 VDC only) Z With light/surge voltage suppressor 2
Light/surge voltage suppressor
200 VAC 50/60 Hz
∗ Power saving circuit R With surge voltage suppressor (Non-polar type) 110 VAC 50/60 Hz Nil Without light/surge voltage suppressor
3
is not available in the U With light/surge voltage suppressor (Non-polar type) [115 V AC 50/60 Hz] S With surge voltage suppressor (Non-polar type)
case of W type. ∗ For AC voltage valves there is no “S” option. 220 VAC 50/60 Hz Z With light/surge voltage suppressor (Non-polar type)
4
It is already built-in to the rectifier circuit. [230 VAC 50/60 Hz] ∗ DOZ is not available.
Rated voltage ∗ For type R and U, DC voltage is only available. ∗ For AC voltage valves there
5 24 VDC ∗ Power saving circuit is only available in the "Z" type. is no “S” option. It is already
6 12 VDC built-in to the rectifier circuit.
V 6 VDC Electrical entry
S 5 VDC G Grommet, 300 mm lead wire
R 3 VDC H Grommet, 600 mm lead wire
1 100 VAC 50/60 Hz
L With lead wire Electrical entry
2 200 VAC 50/60 Hz L plug
LN Without lead wire D DIN With connector
110 VAC 50/60 Hz connector
3 LO Without connector DO terminal Without connector
[115 VAC 50/60 Hz]
220 VAC 50/60 Hz M With lead wire Note) Do not replace V111 (G,
4 M plug Note 1) Enter the cable H, L, M, W) to V115 (DIN
[230 VAC 50/60 Hz] MN Without lead wire
connector length symbols in . terminal) and vice versa
∗ For type W, DC MO Without connector Please be sure to fill when replacing pilot
voltage is only WO M8 Without connector cable in the blank referring valve assembly only.
available. W connector With connector cable Note 1) to back page 10.
∗ For connector cable of M8 connector,
refer to back page 10.
50
Series SYJ7000
For DC : SY100-30-4A-
V100-49-1-
For 100 VAC : SY100-30-1A-
For 200 VAC : SY100-30-2A- Cable length
1 300 mm
For other
voltages of AC : SY100-30-3A- 2 500 mm
3 1000 mm
4 2000 mm
Without lead wire : SY100-30-A 7 5000 mm
(with connector and 2 of sockets only)
51
Series SYJ7000
2 Position Single [ ]: AC
26
34
- +
G: Approx. 300
82 [84.2] H: Approx. 600
59.8 (Lead wire length)
24.1
28.3 39.5 [46.5]
13
3
A B
Manual override
2-ø3.2 17
1/8
85.6 [87.8]
(For manifold mounting) 35 (A, B port)
3.6
-+
28
25
16.1
21
31.5 [38.5]
(A, B port)
Applicable tubing O.D. : ø6, ø1/4"
: ø8, ø5/16"
36
(3.6)
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ7120-L-01 (-F) SYJ7120-M-01 (-F) SYJ7120-D-01 (-F) SYJ7120-WO-01 (-F)
Approx. 300
(Lead wire length)
31.5 [38.5]
57.5
16.1 46.2
31.1 M8 x 1 36
(Lead wire length) 18.5
Approx. 300 42.6 [49.6]
Pg7
91.9 [94.1]
101.9
82.1 [84.3]
101
91
83.6
77.1
61.1
35
35
35
35
28.3
28.3
28.3
28.3
21 21 21 21
(3.6)
(3.6)
(3.6)
(3.6)
52
Series SYJ7000
2 Position Double [ ]: AC
G: Approx. 300
107.4 [111.8] H: Approx. 600
63 (Lead wire length)
3
13
A B A B
Manual override
17 17
2-ø3.2 35 1/8
(For manifold mounting) (A, B port)
One-touch fitting
(4.9)
(A, B port)
2-ø3.2 (Light/surge voltage suppressor) Applicable tubing O.D.: ø6, ø1/4"
(For mounting) 35
: ø8, ø5/16"
36
-+
28
25
16.1
31.5 [38.5]
21
1.6
R1 P R2
18
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ7220-L-01 SYJ7220-M-01 SYJ7220-D-01 SYJ7220-WO-01
Approx. 300
(Lead wire length)
65
31.5 [38.5]
Max. 10
57.5
16.1 46.2
31.1 M8 x 1 36
Approx. 300 42.6 [49.6] 18.5
(Lead wire length)
2-ø3.2
(For mounting) 2-ø3.2
127.2 [131.6]
2-ø3.2 2-ø3.2
107.6 [112]
(For mounting)
(For mounting) (For mounting)
145.4
147.2
125.4
110.6
97.6
65.6
35
35
35
35
21
21
21 25
21 25
28 Pg7
25 25 28
28 Applicable cable O.D.
ø3.5 to ø7 28
Refer to back page 11 for dimentions
with connector cable.
53
Series SYJ7000
G: Approx. 300
122 [126.4] H: Approx. 600
54.5 [56.7] (Lead wire length)
45.3 32.3
3
13
A B A B
Manual override
17 17
2-ø3.2 1/8
(For manifold mounting) 35 (A, B port)
One-touch fitting
(4.9)
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"
36
- +
28
25
16.1
21
31.5 [38.5]
1.6
R1 P R2
18
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SYJ7 45 20-L-01 SYJ7 45 20-M-01 SYJ7 45 20-D-01 SYJ7 45 20-WO-01
Approx. 300
(Lead wire length)
65
Max. 10
54.6 [56.8]
74.4
73.5
63.5
56.1
49.6
33.6
141.8 [146.2]
122.2 [126.6]
35
35
35
35
161.8
160
140
46.6
62.6
28
28
28
Pg7 28
54
Series SYJ7000
2 Position Single [ ]: AC
22
12
34 8.5
2-ø4.3
Manual override B A (For mounting)
27
A
B
R2 P R1
With interface regulator
G: Approx. 300 59.8 3.2
H: Approx. 600 85.2 [87.4]
(Lead wire length)
128.8 [131]
80 [87]
57.5 [64.5]
- +
64.6
54
42.1
36.5
25.5
20
12
11.5
18 1/4 22 22 43.6
34 (R1, R2 port) 31.5
63
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ7140-L- 0102 SYJ7140-M- 0102 SYJ7140-D- 01 02 SYJ7140-WO- 0102
ø3.5 to ø7
91
Max. .10
20 20 20 20
Pg7
95.1 [97.3]
85.3 [87.5]
104.2
94.2
86.8
80.3
22
22
22
22
64.3
63
63
63
63
22
22
22
22
31.5
31.5
31.5
31.5
3.2
3.2
3.2
3.2
55
Series SYJ7000
2 Position Double [ ]: AC
22
12
G: Approx. 300
H: Approx. 600 107.4 [111.8]
(Lead wire length) 63
B A
Manual override R2 P R1
2-ø4.3 34 8.5
(For mounting) 128.8 [131]
80 [87]
57.5 [64.5]
- +
64.6
42.1
36.5
25.5
20
12
11.5
18 1/4 22 22 43.6
34 (R1, R2 port) 31.5
63
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SYJ7240-L- 0102 SYJ7240-M- 0102 SYJ7240-D- 01 02 SYJ7240-WO- 0102
ø3.5 to ø7
91
57.5 [64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
68.6 [75.6] Approx. 300 44.5
20 20 20 20
127.2 [131.6]
Pg7
107.6 [112]
22
22 22
22
22
147.2
145.4
110.6
125.4
97.6
65.6
63
63
63
63
22
22
22
31.5
31.5
31.5
31.5
56
Series SYJ7000
3
Grommet (G), (H): SYJ7 45 40- GH - 01
02
22
12
G: Approx. 300
H: Approx. 600 122 [126.4]
(Lead wire length)
2-ø4.3 36 [38.2]
(For mounting)
B A
27
A
R2 P R1
Manual override 34 8.5
63.8 13.8 129.6 [131.8]
80 [87]
57.5 [64.5]
- +
42.1
36.5
25.5
20
12
11.5
18 1/4 22 22 43.6
34 (R1, R2 port) 31.5
63
L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
02
SYJ7 45 40-L- 01 02
SYJ7 45 40-M- 01 02
SYJ7 45 40-D- 01 02
SYJ7 45 40-WO- 01
ø3.5 to ø7
91
57.5 [64.5] 83.5
42.1 72.2
Pg7 62 M8 x 1
(Lead wire length) 57.1
68.6 [75.6] Approx. 300 44.5
20 20 20 20
141.8 [146.2]
87.6
122.2 [126.6]
81.1
22
22
22 22
22
65.1
161.8
63
63
63
63
160
140
22
22
22
31.5
31.5
31.5
31.5
15.1
45.9 [48.1]
31.1
12 12 12 12
55
Max. 10
57
Series SYJ7000
Manifold Specifications
Manifold Standard
Manifold Specifications
Flow Characteristics
Flow characteristics
Port size
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
Port Port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 1/8 2.2 0.35 0.57 2.3 0.26 0.55
Type SS5YJ7-20 1/8 C6 1.4 0.32 0.37 2.0 0.25 0.49
Body ported 1/8 C8 1.7 0.38 0.45 2.1 0.25 0.51
SYJ72 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
for internal pilot
Type SS5YJ7-21 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Type SS5YJ7-40 1/4 1/8 2.1 0.28 0.51 2.5 0.23 0.59
Base mounted Type SS5YJ7-41 1/4 1/8 2.0 0.30 0.50 2.2 0.30 0.55
for internal pilot Type SS5YJ7-42-C6 SYJ74 1/4 C6 1.5 0.32 0.38 2.2 0.23 0.52
Type SS5YJ7-42-C8 1/4 C8 1.9 0.24 0.46 2.2 0.26 0.53
Note) Value at manifold base mounted, 2 position single operating
58
Series SYJ7000
Flow Characteristics
Flow characteristics
Port size
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
Port Port [dm3/(s·bar)] [dm3/(s·bar)]
Type SS5YJ7-21P-01 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
Body ported
Type SS5YJ7-21P-C6 SYJ723 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
for internal pilot
Type SS5YJ7-21P-C8 1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Note) Value at manifold base mounted, 2 position single operating
59
Series SYJ7000
Manifold Standard
/Common SUP/Common EXH
Type 20 (5 Port/Body ported) How to Order
A, B port SS5YJ7–20– 05 – P, R port
Stations thread type
Applicable solenoid valve
Nil Rc
–+
02 2 stations 01
–+
00F G
P port : : SYJ720-- C6
R
P 1/8 00N NPT C8
R
15 15 stations 00T NPTF 01
R port SYJ723-- C6
C8
1/8 Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Applicable blanking
Type 21 (5 Port/Body ported) How to Order
plate assembly
A, B port SS5YJ7–21– 05 – SYJ7000-21-1A
–+
1/4 02 2 stations 01 1/8 Nil Rc Applicable individual
B R : : F G EXH spacer assembly
P
R N NPT SYJ7000-17-2A
A 20 20 stations
A, B port T NPTF
B R port
1/4 Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. Applicable individual
SUP spacer assembly
Type 42 (5 Port/Base mounted) How to Order
SYJ7000-16-2A
SS5YJ7–42– 05 – C6
Applicable interface
Stations A, B port size Thread type regulator
C6 One-touch fitting for ø6 Nil Rc
–+
–+ 02 2 stations ARBYJ7000-00-P
P port
B R : : C8 One-touch fitting for ø8 F G
P 1/4
R 20 20 stations N7 One-touch fitting for ø1/4" N NPT
A, B port A
T NPTF
B
R port N9 One-touch fitting for ø5/16"
1/4 Note) For more than stations, supply air to both sides of P port and exhaust air from both sides of R port.
Stations
A
B
thread type
A
P port SYJ7000-21-3A
B
03 3 stations
B
1/4 Nil Rc
: : Applicable connector
00F G
12 12 stations 00N NPT assembly
00T NPTF Refer to page 59.
R port
1/4 Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
60
Series SYJ7000
Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Mix Installation of the SYJ700 and the SYJ7000 Valves on the Same Manifold
Round head combination screw Round head combination screw Use of an adapter plate makes it possible to mount Series SYJ700 on the
M3 x 31 M3 x 31 manifold bases of series SYJ7000.
Matt nickel plated Matt nickel plated When mounting the SYJ700 valve on the SYJ7000 manifold, the SYJ700
(with spring washer) (with spring washer)
solenoid must be positioned on the same side of the manifold as a single
solenoid SYJ700. (Refer to the figure below.)
For base mounted style, the A port of the 3 port valve flows out the B port
of manifold base.
7
B B
combination screw
7
A A
O-ring
Manifold
gasket
15
15
R
Applicable manifold base Applicable manifold base
R
R1 R1 Type SS5YJ7-20 Type SS5YJ7-40
Type SS5YJ7-21 Type SS5YJ7-41
Type SS5YJ7-42
Manifold Manifold
gasket gasket Blanking Plate Assembly
Applicable manifold base Applicable manifold base SYJ7000-21-1A
Type SS5YJ7-20 Type SS5YJ7-40
Type SS5YJ7-21 Type SS5YJ7-41 Round head combination screw
Type SS5YJ7-42
Blanking plate
Base mounted
Gasket
15
Individual
SUP spacer
Gasket Applicable manifold base
P
Type SS5YJ7-40
P Type SS5YJ7-41
Type SS5YJ7-42
Applicable manifold base Dust cap
Manifold Applicable manifold base
Type SS5YJ7-40
gasket Type SS5YJ7-21P
Type SS5YJ7-41
Type SS5YJ7-42
Refer to back page 12 prior to handling.
Caution
Mounting screw tightening torques Use caution to the assembly orientation for solenoid valves, gasket, and optional parts.
M3: 0.8 N·m
61
Series SYJ7000
Grommet (G)
Approx. 300
(Lead wire length)
L1 4-ø4.5
L2 6 (For mounting)
6.5
(DIN 7.8)
(DIN 21.6)
15.5
3
20.3
3.3
8
122 [126.4]
17 16.5
107.4 [111.8]
A
25
R
(DIN 58.6)
(DIN 57.8)
17 17
79.5 [81.7]
57.3
50
56.5
78.7 [80.9]
P
P
R
R
1/8
(P, R port)
Manual override
1/8
(Pitch)
(A, B port)
P = 19 20
(Station n) (Station 1)
-+ -+ -+ -+ -+
ø6, ø1/4"
ø8, ø5/16"
40.1
23.5
(4.9) 60
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)
55.5 [62.5] 89
40.1 Pg7 81.5
(Lead wire length)
70.2
Approx. 300 66.6 [73.6] M8 x 1
3.3
3.3
3.3
3.3
141.8 [146.2]
122.2 [126.6]
161.8
127.2 [131.6]
107.6 [112]
125.2
160
140
145.4
147.2
125.4
110.6
78.8 [81]
88.6 [90.8]
80.3
87.7
97.7
98.6
0.8
0.8
42.5
0.8
0.8
60
0.8
0.8
62
Series SYJ7000
Grommet (G)
Approx. 300
(Lead wire length)
L1
4-ø4.5
L2 10 (For mounting)
(DIN 63.6) (DIN 16.6)
(DIN 2.8)
16.5
3
15.3
11.5
1.5
122 [126.4]
107.4 [111.8]
R
A
30
R
(DIN 62.8)
21
83.7 [85.9]
84.5 [86.7]
61.5
62.3
17
21
60
P
P
21
R
R
1/4
(P, R port)
Manual override (Pitch) 1/8
P = 19 23.5 (A, B port)
(Station n) (Station 1)
-+ -+ -+ -+ -+
Applicable tubing O.D.:
ø6, ø1/4"
43.1
ø8, 5/16"
26.5
(4.9) 63
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)
58.5 [65.5] 92
84.5
43.1 Pg7
73.2
(Lead wire length)
Approx. 300 69.6 [76.6] M8 x 1
141.8 [146.2]
122.2 [126.6]
127.2 [131.6]
107.6 [112]
161.8
125.2
160
140
145.4
125.4
110.6
83.8 [86]
93.6 [95.8]
147.2
85.3
92.7
102.7
103.6
0.8
0.8
45.5
0.8
0.8
63
0.8
0.8
63
Series SYJ7000
Approx. 300
(Lead wire length)
Grommet (G)
L1 4-ø4.5
L2 10 (For mounting)
1.5
122 [126.4]
107.4 [111.8]
R
A A A A A
30
R
21 21
83.7 [85.9]
84.5 [86.7]
62.3
61.5
21
60
P
P
B B B B B
R
R
1/4
(P, R port)
Manual override (Pitch)
P = 19 23.5
(Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
58 [65]
42.6
26
B B
19
40
A A
1/8
(A, B port)
(Pitch) 2
P = 19 23.5
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
Approx. 300
(Lead wire length)
58 [65] 91.5
84
42.6 Pg7
72.7
(Lead wire length)
Approx. 300 69.1 [76.1] M8 x 1
141.8 [146.2]
122.2 [126.6]
127.2 [131.6]
107.6 [112]
161.8
125.2
160
140
145.4
147.2
125.4
110.6
83.8 [86]
93.6 [95.8]
85.3
92.7
102.7
103.6
0.8
0.8
45
0.8
0.8
62.5
0.8
0.8
64
Series SYJ7000
Grommet (G)
Approx. 300
(Lead wire length)
L1
14 L2
31.5
20.5
85.2 [87.4]
86 [88.2]
107.4 [111.8]
R
R
B B B B B
(DIN 65.1)
(DIN 64.3)
122 [126.4]
19 19
63.8
19
63
60
P
P
31.5
22
A A A A A
R
R
1/4
(For DIN:
(P, R port)
15.1)
13.8
4-ø4.5
(Pitch)
29 P = 20 (For mounting)
Manual override
(Station 1) (Station n)
(Light/surge voltage suppressor)
-+ -+ -+
73 [80]
57.6
A A
10.5
41
30.5
B B
6.5 1/8
(Pitch)
25 P = 20 (A, B port)
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
106.5
99
73 [80] 87.7
0.8
M8 x 1 77.5
0.8
57.6 60
0.8
0.8
0.8
0.8
95.1 [97.3]
85.3 [87.5]
105.1
104.2
127.2 [131.6]
94.2
107.6 [112]
86.8
141.8 [146.2]
122.2 [126.6]
145.4
147.2
125.4
110.6
161.8
125.2
160
140
ø3.5 to ø7
Approx. 300
65
Series SYJ7000
C8,N9
Type 42: Side Ported/SS5YJ7-42- Stations - C6,N7 [ ]: AC
Grommet (G)
Approx. 300
(Lead wire length)
L1
Manual override
14 L2
4-ø4.5
(For mounting)
32.5
19
85.9 [88.1]
85.1 [87.3]
107.4 [111.8]
(DIN 64.2)
R
B B B B B
R
122 [126.4]
(DIN 65)
18 18.5
62.9
63.7
59.9
21.9 19
P
P
31.4
A A A A A
R
R
(DIN: 15.2)
(4.9)
1/4
13.9
(P, R port)
(Pitch)
29 P = 19
(Station 1) (Station n)
(Light/surge voltage suppressor)
-+ -+ -+
74 [81]
58.6
A A
42
29.5
8.5
B B
8 (Pitch)
25 P = 19 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
107.5
74 [81] 100 M8 x 1
88.7
0.8
0.8
78.5
58.6
0.8
61
0.8
0.8
0.8
95 [97.2]
85.2 [87.4]
104.1
127.2 [131.6]
105
107.6 [112]
94.1
141.8 [146.2]
122.2 [126.6]
86.7
145.4
147.2
125.4
110.6
161.8
125.2
160
140
ø3.5 to ø7
Approx. 300
66
Series SYJ7000
Approx. 300
(Lead wire length)
L1
L2 10
- +
4-ø4.5
(For mounting)
- + - +
16.5
1/8
1.5
15.3
(A, B port)
11.5
141.8 [146.2]
127.2 [131.6]
17 21.5
21 19.5
R
R
30
A
21 21
61.5
62.3
93.6 [95.8]
94.4 [96.6]
60
P
P
93.8
B
R
R
16
- + - + - + - + - +
(Station n) (Station 1)
(Light/surge voltage suppressor)
58.5 [65.5]
32.3
26.5
28.5
Applicable connector: 26 pins MIL type
8.8
(Conforming to MIL-C-83503)
One-touch fitting
(A, B port)
Applicable tubing O.D.:
ø6, ø1/4"
ø8, ø5/16"
(4.9) 63
67
68
4/5 Port Air Operated Valve
Series SYJA3000
How to Order
Bracket
Nil Without bracket
F With bracket
Port size
Type of actuation Nil Without sub-plate
1 2 position single M5 port
M5
2 2 position double With sub-plate
JIS Symbol 3 3 position closed center
4 3 position exhaust center
5 port 4 port
5 3 position pressure center
2 position single 2 position single
(B) (A) (B) (A)
2 4 2 4
3 1 5
1 3
(R) (P) (R)
(P) (R)
3 position closed center 3 position closed center SS5YJA3 Fill the same as SS5YJ3
(B) (A) (B) (A)
2 4 2 4
3 1 5 Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
1 3
(R) (P) (R) with the manifold base model no.
(P) (R)
3 1 5 1 3
(R) (P) (R) (P) (R)
Caution
Refer to back page 1 through to 5 for Safety
Instructions and Common Precautions.
69
Series SYJA3000
Specifications
Fluid Air
Operating pressure 2 position single 0.15 to 0.7
range 2 position double 0.1 to 0.7
MPa 3 position 0.2 to 0.7
Note 1) 2 position single Operating pressure to 0.7
Pilot pressure range 2 position double 0.1 to 0.7
MPa
Base mounted 3 position 0.2 to 0.7
Ambient and fluid temperature °C –10 to 50 (No freezing. Refer to back page 3.)
Lubrication Not required
Mounting orientation Unrestricted
Note 2)
Impact/Vibration resistance (m/s2) 300/50
Note 1) In case of single type, be certain that pressure within operating pressure range be supplied to
supply port, because return pressure is introduced from supply port {1(P)} for activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
The test was performed on the axis and right angle directions of the
main valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve
when pilot signal is ON and OFF. (Value in the initial state)
Body ported
Pilot Pressure Range (Single pilot) With Bracket
0.6
Air operated
SYJA320-M3-F
Pilot pressure MPa
0.2
Note 3)
Flow characteristics Note 2)
Pilot Weight (g) Effective 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB)
Valve model Type of actuation Port size area
port size C [dm3/ C [dm3/
mm2 b Cv b Cv
Grommet (s • bar)] (s • bar)]
Single 48 (22)
5 port Base mounted
Closed
center
SYJA320-M3 M3 x 0.5 M3 x 0.5 0.9
Exhaust
3 position 28
center
Pressure
center
Single 22
4 Port Base Mounted
2 position
(For manifold) Note 1)
Double 25
Closed
SYJA330 center
– M3 x 0.5
Exhaust Note 1) Value when used on a manifold. Refer to page 69 for details.
3 position 28
center Note 2) [ ]: denotes normal position.
Pressure Note 3) ( ): Without sub-plate.
Note 4) 5 port, base mounted without sub-plate: SYJA340
center
70
Series SYJA3000
2-ø3.5 (28.4)
5
10
(For mounting) (22)
(16.4)
(10)
2-ø3.2
Manual override (For mounting) 22 4
M3 x 0.5 B A
11
17.5
2.5
M3 x 0.5 ø1 (Bleed port) (Pilot port)
1.5 (Pilot port)
A
B
1.5
M3 x 0.5 33
(Piping port) 36
Manual override
B
R
(35)
7 7
36
(13.5) 7
28.5
P
15
A
21
ø1
R
13
R2 P R1
(Bleed port)
5
4 15 10
(2)
10 10
8.2 11 M5 x 0.8
(Bracket) (Piping port)
14 14
15
10 9
36
7.1
5
2-M3 x 0.5
10
(Pilot port) 1.8
4
A B
2-ø3.2
1.5
1.5
22
8.2
(For mounting)
2.5
7
2-ø1.8 2-M3 x 0.5 A
B
(For manifold mounting)
11
17.5
2-ø3.2 equivalent (18.5) (Pilot port)
A
B
(For mounting) Manual override
1.5
14
1.5
36
(18.5)
(21)
Manual override
13.5
41.6
15
41.6
28.5
21
R2 P R1
13
(0.5) (11)
R P R
10
3 position closed center/exhaust center/pressure center 3 position closed center/exhaust center/pressure center
3 3
SYJA3 45 20-M3(-F) 7.1
SYJA3 45 40-M5
10 9
2-M3 x 0.5 1.8
5
(Pilot port)
10
4
A B
1.5
7
8.2
19 2-M3 x 0.5
49 2-ø3.2 22 3
2.5
(Pilot port)
(For mounting)
2-ø3.2 equivalent B A
(18.5)
1.5
11
17.5
33 16
(18.5)
(21)
13.5
18.9
15
2-ø1
21
(Bleed port)
(0.5) (11)
R2 P P1
13
R P R
10
71
4/5 Port Air Operated Valve
Series SYJA5000
How to Order
5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
3 position closed center 3 position exhaust center
(A) (B) (A) (B)
4 2 4 2
How to Order Manifold Base
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
3 position pressure center Same manifolds as series SYJ5000 are prepared.
(A) (B)
4 2
3 1 3 1
(R) (P) (R) (P)
(Ex.)
3 position closed center 3 position exhaust center
(B) (A)
SS5YJA5-42-03-01 ············ 1 set
(B) (A)
2 4 2 4 ∗ SYJA5140 ······························· 1 set
∗ SYJA5240 ······························· 1 set
3 1
∗ SYJ5000-21-1A ····················· 1 set
3 1
(R) (P) (R) (P)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
3 position pressure center
(B) (A)
2 4
3 1
(R) (P)
Caution
Refer to back page 1 through to 5 for Safety
Instructions and Common Precautions.
72
Series SYJA5000
Specifications
Fluid Air
Operating pressure 2 position single 0.15 to 0.7
range 2 position double 0.1 to 0.7
MPa 3 position 0.15 to 0.7
Note 1) 2 position single (0.4 x P+0.1) to 0.7 P: Operating pressure
Pilot pressure range 2 position double 0.1 to 0.7
MPa
3 position 0.15 to 0.7
Ambient and fluid temperature °C –10 to 50 (No freezing. Refer to back page 3.)
Lubrication Not required
Base mounted Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note 2) 300/50
Note 1) In case of single type, be certain that pressure within operating pressure range be supplied
to supply port, because return pressure is introduced from supply port {1(P)} for activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis
and right angle directions of the main valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve when pilot signal is ON and
OFF. (Value in the initial state)
0.5
Pilot pressure range The mounting brcket is supplied unttached.
0.4
0.3
0.2
A, B port: C4
Closed center (One-touch 0.69 0.40 0.19 0.43 0.40 0.12
SYJA520-C4 Exhaust fitting for ø4) 0.41 0.37 0.10
M5 x 0.8
3 position P, R port: 0.56 0.40 0.15 77
center [0.41] [0.37] [0.11]
Pressure M5 x 0.8 0.57 0.40 0.15 0.41 0.37 0.10
center [0.41] [0.37] [0.10]
Single 52
2 position 0.70 0.36 0.19 0.47 0.40 0.12
Double 67
A, B port: C6
Closed center (One-touch 0.72 0.37 0.19 0.44 0.34 0.12
SYJA520-C6 fitting for ø6)
Exhaust 0.41 0.38 0.11 77
3 position P, R port: 0.67 0.54 0.19
[0.41] [0.38] [0.11]
center
M5 x 0.8
Pressure 0.82 0.41 0.23 0.41 0.36 0.11
center [0.44] [0.39] [0.12]
Single
0.79 0.21 0.19 0.83 0.32 0.21
79 (45)
2 position
(with sub-plate)
Double 94 (60)
Base mounted
73
Series SYJA5000
1
Manual override (For mounting)
15
11
5
A B (Pilot port) B A
1
M5 x 0.8
24
10
A
B
(Pilot port) R P
19
2-ø2.6 2-ø3.5
(Bracket) (For manifold mounting) (For mounting) 37.5 4
42
Manual override 47
(30)
24.5
(37)
23
11.5
20
3
3.5 4 11 2-ø2.6
(18) ø1.8
46.5
19.5 (For mounting) 1/8
(25) (Bleed port)
33.5
(Piping port)
(2.3) (46.5)
21.5
With fiflter
(80 mesh)
8.5
M5 x 0.8
6
6
R1 P
(Piping port) 15 17 17
R2 ø1.8 (Bleed port) 24 45.5
With fiflter (80 mesh) 32
21
2-ø4.3
44 2-M5 x 0.8
2-M5 x 0.8 (For mounting)
(Pilot port)
(Pilot port)
B A
1
11
1
5
A B
24
A
B
1
1
10 2-ø2.6 R P
11.5
3
With fiflter
R1 P
(Piping port) (80 mesh) 8.5
6
6
R2
2-ø1.8 (Bleed port) 15 17 17
21 With fiflter (80 mesh) 24 45.5
32
3 position closed center/exhaust center/pressure center 3 position closed center/exhaust center/pressure center
3 3
SYJA5 45 20-M5 27.6 SYJA5 45 40-01 2-M5 x 0.8 2-ø4.3
37.4 2-M5 x 0.8 22.6 (Pilot port) (For mounting)
(Pilot port)
B A
11
5
A B
24
1
A
1
10 2-ø2.6
R P
11.5
3
11 2-ø2.6
1/8
46.5
(Piping port)
M5 x 0.8
21.5
(Piping port)
2-ø1.8
(Bleed port)
6
R1 P
15 With fiflter
17 17
8.5
R2 24 (80 mesh)
45.5
2-ø1.8 (Bleed port) 32
21
With fiflter (80 mesh)
74
4/5 Port Air Operated Valve
Series SYJA7000
How to Order
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
3 position closed center 3 position exhaust center
(A) (B) (A) (B)
4 2 4 2
How to Order Manifold Base
5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2)
3 position pressure center Same manifolds as series SYJ7000 are prepared.
(A) (B)
4 2
Base mounted
2 position single 2 position double Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
(B) (A) (B) (A) with the manifold base model no.
2 4 2 4
3 1 5 3 1 5 (Ex.)
(R2) (P) (R1) (R2) (P) (R1) SS5YJA7-41-03-01 ········· 1 pc.
3 position closed center 3 position exhaust center ∗ SYJA7140 ······························ 1 pc.
(B) (A) (B) (A)
2 4 2 4 ∗ SYJA7240 ······························ 1 pc.
∗ SYJ7000-21-1A ··················· 1 pc.
3 1 5 3 1 5
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
(R2) (P) (R1) (R2) (P) (R1)
3 1 5
(R2) (P) (R1)
Caution
Refer to back page 1 through to 5 for Safety
Instructions and Common Precautions.
75
Series SYJA7000
Specifications
Fluid Air
Operating pressure 2 position single 0.15 to 0.7
range 2 position double 0.1 to 0.7
MPa 3 position 0.15 to 0.7
Note 1) 2 position single (0.4 x P+0.1) to 0.7 P: Operating pressure
Pilot pressure range 2 position double 0.1 to 0.7
MPa
3 position 0.15 to 0.7
Ambient and fluid temperature °C –10 to 50 (No freezing. Refer to back page 3.)
Base mounted Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note 2) 300/50
Note 1) In case of single type, be certain that pressure within operating pressure range be supplied to
supply port, because return pressure is introduced from supply port {1(P)} for activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
The test was performed on the axis and right angle directions of the
main valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve
when pilot signal is ON and OFF. (Value in the initial state)
Body ported
Pilot Pressure Range (Single pilot) With Bracket
0.6
Air operated
SYJA7120-01-F
valve
0.5
Pilot pressure MPa
0.3
0.2
76
Series SYJA7000
Flow Characteristics/Weight
Valve model Type of actuation Port size 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) Pilot Weight
port size (g)
C [dm3/ b Cv C [dm3/
(s • bar)] (s • bar)] b Cv
Single 90
2 position 2.2 0.36 0.58 2.4 0.34 0.63
Double 110
Closed
1.8 0.37 0.45 2.0 0.35 0.49
center
SYJA720-01 1/8
Exhaust 3.0 0.35 0.73
3 position 1.2 0.50 0.34 120
center [1.3] [0.52] [0.39]
Pressure 3.0 0.37 0.78
1.8 0.37 0.45
center [0.83] [0.50] [0.25]
Single 101
2 position 1.6 0.33 0.4 2.2 0.32 0.53
Double 121
Closed
Body ported
77
Series SYJA7000
1
B A
13
3
A B
34
27
B
17 M5 x 0.8
A
2-ø3.2
(For manifold mounting) 35 (Pilot port) R2 P R1
(44)
(P, A, B port)
(36)
21
14
65.6
(69.2)
54
55
(31.9) (26) ø1.8
40
25.5
1/8 (Bleed port)
20
(34)
11.5
12
(Piping port) With fiflter
R1 P R2 Manual override (80 mesh)
18
1.6
22 22
1/4
ø1.8 (Bleed port) 31.5
27.2 (R1, R2 port)
With fiflter (80 mesh) 63
(Pilot port)
13
3
B A
A B
1
1
34
27
2-ø3.2 17 2-M5 x 0.8
A
B
1
(For manifold mounting) 35 (Pilot port)
R2 P R1
2-ø3.2 31.5
35 (For mounting) 18 63.6
Manual override
74.6
28
29
25
21
14
74.6
Manual override
55
1/8
2-ø1.8
40
25.5
(Piping port)
(Bleed port)
20
1.6
12
R1 P With fiflter 11.5
R2
18 (80 mesh) 22 22
2-ø1.8 (Bleed port) 63 1/4
27.2
With fiflter (80 mesh) (R1, R2 port)
1/8,1/4
(P, A, B port)
34
27
13
A B
1
3
1
1
R2 P R1
45.6 32.6 2-M5 x 0.8
38.1 31.5
2-ø3.2 (Pilot port) 64
(For mounting) 35 Manual override 69.5 14
89
Manual override 1/8,1/4
29
28
25
(P, A, B port)
21
14
89.2
18
2-ø1.8 (Bleed port)
55
(Bleed port)
20
1.6
11.5
12
R1 P R2
With fiflter
18 (80 mesh) 22 22
27.2 63 1/4
1/8 (R1, R2 port)
(Piping port)
78
Series SYJ5000/7000
Made to Order
(For detailed specifications, delivery and pricing, please contact SMC.)
SYJ 5
7 20R X20
Dimensions
SYJ5000: 8 mm
longer in total length.
SYJ7000: 8 mm
JIS Symbol
Body ported
2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center
(A)(B) (A)(B) (A)(B) (A)(B) (A)(B)
4 2 4 2 4 2 4 2 4 2
5 1 3 5 1 3 5 1 3 5 1 3 5 1 3
(R1) (P) (R2) (R1) (P) (R2) (R1) (P) (R2) (R1) (P) (R2) (R1) (P) (R2)
X X X X X
79
Series SYJ5000/7000
Made to Order
DIN Connector Conforming to EN-175301-803C (former DIN 43650C)
DIN connector type that conforms to the 8 mm pitch standards between DIN terminals.
How to Order Valve
Light/surge voltage suppressor
Type of actuation
Nil Without light/surge voltage suppressor
1 2 position single solenoid
S With surge voltage suppressor
2 2 position double solenoid
Z With light/surge voltage suppressor Bracket
3 3 position closed center
∗ YOZ is not available. Nil Without bracket
4 3 position exhaust center ∗ For AC voltage valves there is no “S” option. F With bracket
5 3 position pressure center It is already built-in to the rectifier circuit.
Rated Note) Do not remove the factory
voltage installed bracket from
DC AC (50/60 Hz) models with the bracket
5 24 VDC 1 100 VAC
A, B port size option. Removal of he
M5 M5 x 0.8 bracket will cause the
6 12 VDC 2 200 VAC
01 1/8 (SYJ7000 only) valve to leak.
3 110 VAC [115 VAC]
4 220 VAC [230 VAC] C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
N3 One-touch fitting for ø5/32"
N7 One-touch fitting for ø1/4"
80
Series SYJ
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by labels of
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1),
JIS B 8370 Note 2) and other safety practices.
Warning
1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements. The expected performance and safety assurance will be the responsibility of the
person who has determined the compatibility of the system. This person should continuously review
the suitability of all items specified, referring to the latest catalog information with a view to giving due
consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery
and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driver objects have been confirmed.
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston
rod, etc.
4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and
brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.
Back page 1
4/5 Port Solenoid Valves/Common Precautions 1
Be sure to read before handling.
Design Selection
Warning Warning
1. Actuator drive 1. Confirm the specification
When an actuator, such as a cylinder, is to be driven using a The products presented in this catalog are designed only for
valve, take appropriate measures to prevent potential danger use in compressed air systems (including vacuum). Do not
caused by actuator operation. operate at pressures or temperatures, etc., beyond the range
2. Intermediate stopping of specifications, as this can cause damage or malfunction.
(Refer to specifications.)
When a 3 position closed center valve is used to stop a
Contact SMC when using a fluid other than compressed air
cylinder at an intermediate position, accurate stopping of the
(including vacuum).
piston in a predetermined position is not possible due to the
compressibility of air. Furthermore, since valves and cylinders 2. Extended periods of continuous energization
are not guaranteed for zero air leakage, it may not be possible • Continuous energization of the valve for extended periods of
to hold a stopped position for an extended length of time. time may have an adverse effect on the solenoid valve
Contact SMC if it is necessary to hold a stopped position for performance and the peripheral equipment due to
an extended time. temperature rises caused by the heat generation of the coil.
3. Effect of back pressure when using a Consult with SMC if valves will be continuously energized for
extended periods of time or the energized period per day will
manifold be longer than the de-energized period. It is also possible to
Use caution when valves are used on a manifold, as actuator shorten the energization period by using valves of the N.O.
malfunction due to back-pressure may occur. In case of 3 (normally open) type.
position closed exhaust center valve or single acting cylinder, • When solenoid valves are mounted in a control panel,
take appropriate measures to prevent the malfunction using employ measures to radiate excess heat, so that
with individual EXH interface assembly or individual exhaust temperatures remain within the valve specification range.
manifold. Use special caution when three or more stations sequentially
4. Holding of pressure (including vacuum) aligned on the manifold are continuously energized since
Since valves are subject to air leakage, they cannot be used this will cause a drastic temperature rise.
for applications such as holding pressure (including vacuum) (As for AC specifications, since the applicable products are
in a pressure vessel. ready to provide separately, contact SMC.)
5. Cannot be used as an emergency shut off
valve, etc.
The valves presented in this catalog are not designed for Caution
safety applications such as an emergency shut off valve. If the 1. Momentary energization
valves are used in this type of system, other reliable safety
If a double solenoid valve will be operated with momentary
assurance measures should also be adopted.
energization, it should be energized for at least 0.1 second.
6. Maintenance space However, depending on the secondary load conditions, it
The installation should allow sufficient space for maintenance should be energized until the cylinder reaches the stroke end
activities (removal of valve, etc.). position, as there is a possibility of malfunction otherwise.
7. Release of residual pressure 2. Leakage voltage
Provide a residual pressure release function for maintenance When using a resistor in paral- Switching element
OFF
purpose. Especially in case of 3 position closed center valve, lel with the switching element
C R
or using a C-R element (surge
Leakage
voltage
Valve
cylinder. voltage suppressor) for protec- Leakage current
tion of the switching element,
8. Vacuum applications note that leakage voltage will
When a valve is used for vacuum switching, etc., take increase due to leakage current flowing through the resistor or
measures against the suction of external dust or other C-R element. Limit the amount of residual leakage voltage to
contaminants from vacuum pads and exhaust ports, etc. the following value:
Moreover, an external pilot type valve should be used in this
case. Contact SMC in case of an internal pilot type or air With DC coil : 3% or less of rated voltage
operated valve, etc.
With AC coil : 8% or less of rated voltage
9. About using the double solenoid type
When using the double solenoid type for the first time,
actuators may travel in an unexpected direction depending on
the switching position of a valve. Implement countermeasures
not to occur any danger by the actuator's operation.
10. Ventilation
When a valve is used inside a sealed control panel, etc.,
provide ventilation to prevent a pressure increase caused by
exhausted air inside the control panel or temperature rise
caused by the heat generated by the valve.
Back page 2
4/5 Port Solenoid Valves/Common Precautions 2
Be sure to read before handling.
Caution Caution
3. Solenoid valve drive for AC with solid state 1. Preparation before piping
output (SSR, TRIAC output, etc.) Before piping is connected, it should be thoroughly blown out
with air (flushing) or washed to remove chips, cutting oil and
1) Current leakage
other debris from inside the pipe.
When using a snubber circuit (C-R element) for surge
protection of the output element, a very small electric 2. Wrapping of sealant tape
current will still continue to flow in spite of the OFF state. When connecting pipes and fittings, etc., be sure that chips
This results in the valve not returning. In the cases when from the pipe thread and sealing materials do not get inside
exceeding the tolerance as shown above, take measures to the valve. Furthermore, when pipe tape is used, leave 1.5 to 2
install a bleeder resistor. thread ridges exposed at the end of the threads.
2) Minimum load allowable amount (Min. load current)
Winding
When the consumption current of a valve is less than the direction
output element’s minimum load allowable volume or the
margin is small, the output element may not be switched
normally. Please confirm SMC. Ex
po Pipe tape
se
4. Surge voltage suppressor thr app
ea ro
If a surge protection circuit contains non-ordinary diodes such ds x.
2
as Varistor, a residual voltage that is in proportion to the
protective elements and the rated voltage will remain. 3. Closed center valves
Therefore, give consideration to surge voltage protection of the
controller. In the case of diodes, the residual voltage is When using closed center type valves, carefully check to
approximately 1 V. ascertain that there is no air leakage from the piping between
the valves and cylinders.
5. Use in low temperature environments
Unless otherwise indicated in the specifications for each valve,
4. Screwing in fittings
operation is possible to –10°C, but appropriate measures When connecting fittings to valves, tighten as indicated below.
should be taken to avoid solidification or freezing of drainage 1) For M3 and M5 type
and moisture, etc. (1) When using SMC fittings, follow the guidelines below.
After tightening by hand, tighten an additional M3: 1/4,
6. Operation for air blowing M5: 1/6 turn with a tightening tool. However, if miniature
When using a solenoid valve for air blow, use an external pilot fittings are used, tighten an additional 1/4 turn with a
type. tightening tool after tightening by hand. For fittings with
Take note that when internal pilots and external pilots are used gaskets in 2 locations, e.g., universal elbow or universal
on the same manifold, the pressure drop caused by the air tee, tighten an additional 1/2 turn.
blowing can have an effect on the internal pilot type valves. Note) If fittings are over-tightened, air leakage may result
Moreover, when compressed air within the pressure range of due to breaking of fitting threads or deformation of the
the established specifications is supplied to the external pilot gaskets. However, if fittings are not tightened
port, and a double solenoid valve is used for air blowing, the sufficiently, loosening of the threads and air leakage
solenoids should normally be energized when air is being and may occur.
blown.
(2) When fittings other than SMC fittings are used, follow the
7. Mounting orientation instructions of the respective fitting manufacturer.
Rubber seal: Refer to the specifications of each series. 2) For Rc (PT)
When installing fitting, etc., follow the given torque levels
below.
Mounting Tightening Torque for Piping
Connection threads Applicable tightening torque N·m
Warning 1/8 7 to 9
1. If air leakage increases or equipment does 1/4 12 to 14
not operate properly, stop operation. 3/8 22 to 24
Check mounting conditions when air and power supplies are 1/2 28 to 30
connected. Initial function and leakage tests should be 3/4 28 to 30
performed after installation.
1 36 to 38
2. Instruction manual 11/4 40 to 42
Mount and operate the product after reading the manual 11/2 48 to 50
carefully and understanding its contents. 2 48 to 50
Also keep the manual where it can be referred to as necessary.
3. Painting and coating 5. Connection of piping to products
Warnings or specifications printed or pasted on the product When connecting piping to a product, refer to its instruction
should not be erased, removed or covered up. Consult with manual to avoid mistakes regarding the supply port, etc.
SMC if paint is to be applied to resinous parts, as this may
have an adverse effect due to the paint solvent.
Back page 3
4/5 Port Solenoid Valves/Common Precautions 3
Be sure to read before handling.
Caution Caution
1. Polarity 1. Install air filters.
When connecting power to a DC specification solenoid valve Install air filters close to valves at their upstream side. A
equipped with (indicator light) surge voltage suppressor, filtration degree of 5 µm or less should be selected.
confirm whether or not there is polarity. 2. Install an air dryer, after cooler or Drain
If there is polarity, take note of the following points.
Without built-in diode to protect polarity (including any power
Catch (water separator), etc.
saving circuit): Air that includes excessive drainage may cause malfunction of
If a mistake is made regarding polarity, the diode in the valves and other pneumatic equipment. To prevent this, install
valve, the control device switching element or power supply an air dryer, after-cooler or Drain Catch (water separator), etc.
equipment, etc., may burn out. 3. If excessive carbon dust is generated,
With diode to protect polarity: eliminate it by installing mist separators at
If a mistake is made regarding polarity, it will not be possible the upstream side of valves.
to switch the valve.
If excessive carbon dust is generated by the compressor, it
2. Applied voltage may adhere to the inside of valves and cause malfunction.
When electric power is connected to a solenoid valve, be Refer to “SMC Best Pneumatics” catalog Vol. 14 for compressed
careful to apply the proper voltage. Improper voltage may air quality.
cause malfunction or coil damage.
3. Confirm the connections.
After completing the wiring, confirm that the connections are Operating Environment
correct.
Warning
Lubrication 1. Do not use valves in atmospheres of
corrosive gases, chemicals, salt water, water
Caution or steam or where there is direct contact
1. Lubrication with any of these.
[Rubber seal] 2. Products with IP65 enclosures (based on
1) The valve has been lubricated for life at the factory, and IEC60529) are protected against dust and
does not require any further lubrication. water, however, these products cannot be
2) In the event that it is lubricated, use class 1 turbine oil used in water.
(without additives), ISO VG32. Take measures to prevent water and dust
However, once lubrication is applied it must be continued,
as loss of the original lubricant may lead to malfunction. from coming from the exhaust port.
Contact SMC regarding class 2 turbine oil (with additives), 3. Products compliant to IP65 satisfy the
ISO VG32. specifications by mounting each product
properly. Be sure to read the Specific
Air Supply Product Precautions for each product.
4. Do not use in an explosive atmosphere.
Warning 5. Do not use in locations subject to vibration
1. Use clean air. or impact. Confirm the specifications in the
Do not use compressed air which contains chemicals, main section of the catalog.
synthetic oils containing organic solvents, salts or corrosive 6. A protective cover, etc., should be used to
gases, etc., as this can cause damage or malfunction.
shield valves from direct sunlight.
7. Shield valves from radiated heat generated
by nearby heat sources.
8. Employ suitable protective measures in
locations where there is contact with water
droplets, oil or welding spatter, etc.
9. When solenoid valves are mounted in a
control panel or are energized for extended
periods of time, employ measures to radiate
excess heat, so that temperatures remain
within the valve specification range.
Back page 4
4/5 Port Solenoid Valves/Common Precautions 4
Be sure to read before handling.
Maintenance
Warning
1. Perform maintenance procedures as shown
in the instruction manual.
If handled improperly, malfunction or damage of machinery or
equipment may occur.
2. Equipment removal and supply/exhaust of
compressed air
When equipment is removed, first confirm that measures are
in place to prevent dropping of work pieces and run-away of
equipment, etc. Then cut the supply pressure and power, and
exhaust all compressed air from the system using its residual
pressure release function.
In the case of 3 position closed center style, exhaust the
residual pressure between valve and cylinder.
When the equipment is to be started again after remounting or
replacement, first confirm that measures are in place to
prevent lurching of actuators, etc., and then confirm that the
equipment is operating normally.
3. Low frequency operation
Valves should be switched at least once every 30 days to
prevent malfunction. (Use caution regarding the air supply.)
4. Manual override operation
When the manual override is operated, connected equipment
will be actuated. Confirm safety before operating.
Caution
1. Drain flushing
Remove drainage from air filters regularly.
Back page 5
Series SYJ3000/5000/7000
Specific Product Precautions 1
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.
Manual Override Operation Solenoid Valve for 200 V, 220 VAC Specifications
Warning Warning
When the manual override is operated, connected equipment Solenoid valves with grommet and L/M type plug connector AC
will be actuated. Confirm safety before operating. specifications have a built-in rectifier circuit in the pilot section to
operate the DC coil.
With 200 V, 220 VAC specification pilot valves, this built-in
Non-locking push type [Standard] rectifier generates heat when energized. The surface may
Press in the direction of the arrow become hot depending on the energized condition; therefore, do
not touch the solenoid valves.
LOCK
possibility that dust could enter the pilot exhaust and damage
the valve.
Ensure that the piping of exhaust air is not too restrictive.
Caution
When operating the locking type D with a screw driver, turn it Series SYJ3000/5000/7000
gently using a watchmakers screw driver. Mixed Installation of 3 Port and 5 Port Valves
[Torque: Less than 0.1 N.m]
on Same Manifold.
LOCK
4 2 Plug Plug 4 2
Single
5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
Back page 6
Series SYJ3000/5000/7000
Specific Product Precautions 2
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.
Caution Caution
1. Attaching and detaching connectors Standard length is 300 mm, but the following lengths are also
• To attach a connector, hold the lever and connector unit available.
between your fingers and insert straight onto the pins of the
solenoid valve so that the lever’s pawl is pushed into the
groove and locks. How to Order Connector Assembly
• To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
For DC: SY100 30 4A
connector straight out.
For 100 VAC: SY100 30 1A
Cover
Groove
Pin
For 200 VAC: SY100 30 2A
Cover
Groove
Lever For other voltages of AC: SY100 30 3A
Pin
DC polarity display
Without lead wire: SY100 30 A Lead wire
-+
Socket
(with connector and 2 of sockets only) length
Connector Lead wire
Nil 300 mm
Hook
How to Order 6 600 mm
Include the connector assembly part 10 1000 mm
number together with the part number 15 1500 mm
for the plug connector’s solenoid valve 20
2. Crimping of lead wires and sockets without connector.
2000 mm
25 2500 mm
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the
Ex.) In case of 2000 mm of lead wire 30 3000 mm
ends of the core wires evenly into the sockets, and then crimp
50 5000 mm
with a crimping tool. When this is done, take care that the For DC For AC
coverings of the lead wires do not enter the core wire crimping SYJ3120-5LO-M3 SYJ3120-1LO-M3
area.
SY100-30-4A-20 SY100-30-1A-20
Use an exclusive crimping tool for crimping.
(Contact SMC for special crimping tools.)
Hook Insulation
Socket Connector
Lead wire
Hook
Back page 7
Series SYJ3000/5000/7000
Specific Product Precautions 3
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.
Caution
<For DC>
Grommet, L/M Plug Connector DIN Terminal
Standard type (with polarity) With surge voltage suppressor (DS)
Surge voltage suppressor (S)
Diode to prevent reverse current
Varistor
Red (+) Coil
Coil
Black
With light/surge voltage suppressor (Z) With light/surge voltage suppressor (DZ)
Diode to prevent reverse current
Red (+)
Varistor
Coil Coil
Black
DIN terminal has no polarity.
Non-polar type
With surge voltage suppressor (R)
(–) (+) M8 Connector
Varistor Coil (Ground) Standard type (with polarity)
(+) (–) With light/surge voltage suppressor (S)
4
With light/surge voltage suppressor (U) Diode to prevent reverse current
(–) (+)
1 (+)
Varistor Coil
1 3 Coil
(+) (–)
3 (–)
• Connect the standard type in accordance with the +, – Solenoid valve side
polarity indication. (The non-polar type can be used with the pin wiring diagram With light/surge voltage suppressor (Z)
connections made either way.) Diode to prevent reverse current
• Since voltage specifications other than standard 24 V and 12
VDC do not have diodes for polarity protection, be careful 1 (+)
Diode
Back page 8
Series SYJ3000/5000/7000
Specific Product Precautions 4
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.
(Rating symbol)
Coil (Light mounting
Refer to table of DIN
connector part no. below. location)
( ) Terminal block
Terminal screw
(3 locations) Notch
DIN Terminal Tightening torque
With light (DZ) ( ) 0.2 to 0.25 N•m
Varistor
Coil
( )
DIN Connector Part No.
NL: Neon light
When making connections, take note that using other than the Note) Refer to page 80 for DIN connector (Y) conforming to EN-175301-803C (former
DIN 43650C).
supported size (ø3.5 to ø7) heavy duty cord will not satisfy IP65
(enclosure) standards. Also, be sure to tighten the ground nut
and holding screw within their specified torque ranges.
Caution
Changing the entry direction
After separating the terminal block and housing, the cord entry
can be changed by attaching the housing in the desired direction
(4 directions at 90° intervals).
∗ When equipped with a light, be careful not to damage the light
with the cord’s lead wires.
Precautions
Plug in and pull out the connector vertically without tilting to one
side.
Compatible cable
Cord O.D.: ø3.5 to ø7
(Reference) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306
Back page 9
Series SYJ3000/5000/7000
Specific Product Precautions 5
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.
Caution Caution
Connector assembly with dust proof protective cover. 1. M8 connector types have an IP65 (enclosure) rating, offering
• Effective to prevention of short circuit failure due to the entry of protection from dust and water. However please note: these
foreign matter into the connector. products are not intended for use in water.
• Chloroprene rubber for electrical use, which provides outstand- Select a SMC connector cable (V100-49-1-) or a FA sensor
ing weather resistance and electrical insulation, is used for the type connector, with M8 threaded 3 pin specifications
cover material. However, do not allow contact with cutting oil, conforming to Nippon Electric Control Equipment Association
etc. Standard, NECA4202 (IEC60947-5-2). Make sure the
• Simple and unencumbered appearance by adopting round-shap- connector O.D. is 10.5 mm or less when used with the Series
ed cord. SYJ3000 manifold. If more than 10.5 mm, it cannot be
mounted due to the size.
2. Do not use a tool to mount the connector, as this may cause
damage. Only tighten by hand. (0.4 to 0.6 Nm)
How to Order
3. The excessive stress on the cable connector will not be able to
satisfy the IP65 rating. Please use caution and do not apply a
SY100 68 A stress of 30 N or greater.
Lead wire length
Nil 300 mm Caution
6 600 mm Failure to meet IP65 performance may result if using alternative
10 1000 mm connectors than those shown above, or when insufficiently tight-
15 1500 mm ened.
20 2000 mm
25 2500 mm • Connector cable mounting
30 3000 mm
50 5000 mm
Triangle mark
Arrow mark
Connector Assembly with Cover: Dimensions
(40) Gray
(10)
(8)
(ø4.1)
(6.9)
Red Black
(8)
Connector cable
M8 connector cable for M8 can be ordered as follows:
How to Order
Enter the part number for a plug connector solenoid valve without How to Order
connector together with the part number for a connector assem- 1. To order solenoid valve and connector cable at the same time.
bly with cover. (Connector cable will be included in the shipment of the
Ex. 1) Lead wire length of 2000 mm solenoid valve.)
SYJ3120-5LOZ-M3
SY100-68-A-20 3
Ex. 2) Lead wire length of 300 mm (standard)
SYJ 57
SYJ3120-5LPZ-M3 Electrical entry
W1: Cable length 300 mm
Symbol for connector assembly with cover W2: Cable length 500 mm
W3: Cable length 1000 mm
∗ In this case, the part number for the connector assembly with W4: Cable length 2000 mm
cover is not required. W7: Cable length 5000 mm
Ex. 1) Cable length: 300 mm
SYJ3120-5W1ZE-M3
Symbol for electrical entry
Back page 10
Series SYJ3000/5000/7000
Specific Product Precautions 6
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.
3 1
Black: 4
Side A
Side B
Side A
Side B
Side A
Side B
Side A
Side B
Side A
Side B
Triangle mark
33.9
Coil
Coil
Coil
Coil
Coil
Coil
Coil
Coil
Coil
Coil
indicator
position
L 35 10 25 23
7 5 3 1
Note)
26 24
8 6 4 2 Connector
Cable length (L) No.
300 mm V100-49-1-1
(+) (-)
Common (+) (-)
{ Common
2000 mm V100-49-1-4
{ Side
{ Side
{ Side
5000 mm V100-49-1-7
{
Connected
on the Station 12 Station 4 Station 3 Station 2 Station 1
printed board
22 33.9
Max. 12 stations 1
Triangle mark 2
3
Note) 24
Terminal no. is not indicated on the connector. 25
The terminal no. indicated in the connection Reference figure 26
14
Caution
Mount it so that there is no slippage or deformation in gaskets,
and tighten with the tightening torque as shown below.
Model Thread size Tightening torque
SYJ3000 M1.7 0.12 N·m
SYJ5000 M2.5 0.45 N·m
SYJ7000 M3 0.8 N·m
Back page 11
Series SYJ3000/5000/7000
Specific Product Precautions 7
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.
Caution Note 1) Set the pressure within the operating pressure range of
the solenoid valve.
Pilot valves in this series are improved to provide excellent energy Note 2) The maximum operating temperature for the solenoid
saving results. However following this improvement, these new valve is 50°C.
valves are no longer compatible with the conventional pilot valve Note 3) The effective area listed is for a single solenoid 2 position
used at the interface. Consult with SMC when you need to valve mounted on a sub-plate.
exchange these pilot valves, in the case of manual override Note 4) Apply pressure from P port in the base for interface
(marked in orange) of the adapter plate. regulator.
New type Manual override
(Blue) Flow Characteristics
(P → A) Condition: Inlet pressure 0.7 MPa
-+
B
A
ARBYJ5000-00-P
Interface
0.6
0.5
Pilot valve
(V111)
Outlet pressure (MPa)
Adapter plate
0.4
Conventional type
Manual override
0.3
(Orange)
-+
B
A
0.2
Interface
0.1
0
0 50 100 150 200
Pilot valve
(SY114) Adapter plate Flow rate l/min (ANR)
ARBYJ7000-00-P
Interface Regulator
0.6
Caution
0.5
Outlet pressure (MPa)
Specifications 0.2
Interface regulator ARBYJ5000 ARBYJ7000
Regulating port P P
0
Proof pressure 1.5 MPa 0 100 200 300 400
Flow rate l/min (ANR)
Maximum operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa Note 1)
Ambient and fluid temperature -5 to 60°C (No freezing) Note 2)
Thread size for connection of pressure gauge M5 x 0.8
Weight (kg) 0.06 0.09
Effective area at exhaust Note 3) P→A 1.9 5.1
side (mm2)
S at P1 = 0.7 MPa, P2 = 0.5 MPa P→B 2.1 5.8
Effective area at supply Note 3)
A → EA 4.5 12.6
side (mm2)
S at P1 = 0.7 MPa, P2 = 0.5 MPa B → EB 4.5 12.6
Back page 12
SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK
Variations
Option
Sonic conductance Type of Manual
Series Voltage Electrical entry
C[dm3/(s·bar)] actuation Light/Surge override
voltage suppresser
10-SYJ5000
0.47 왎 With light/surge
L plug connector voltage suppressor
4/2→5/3
(A/B→EA/EB) }
P.515
+
–
10-SYJ7000 For AC
2.4 2 position M plug connector
4/2→5/3
(A/B→EA/EB) } · Single
· Double
왎AC 100V / Hz
50
60
AC 110V 50
/ Hz60
AC 200V 50
/ Hz60 +–
P.537 AC 220V 50
/ Hz60
왎 Non-locking
push type
10-SYJ3000
3 position
0.46
· Closed center
4/2→5/3
(A/B→EA/EB) } · Exhaust center
· Pressure center
왎 Push-turn
Base mounted type
10-SYJ7000 M8 connector
2.9
4/2→5/3
(A/B→EA/EB) }
P.537
Note) All standard AC voltage models have built-in surge voltage suppresser.
492
4/5 port solenoid valve Series 10-SYJ3000/5000/7000
Manifold variations
A, B port size Manifold option
One-touch fitting
Air cylinder
A, B port Flat ribbon cable manifold
Valve series Individual Individual
location M3 M5 1/8 Applicable tubing O.D. SUP spacer EXH spacer
assembly assembly
ø4 ø6 ø8 N3 N7 N9
10-SYJ3000 앬 — — — — — — — — — — 앬
Body ported
Rotary actuator
10-SYJ5000 Top — 앬 — 앬 앬 — 앬 앬 — 앬 앬 앬
10-SYJ7000 — — 앬 — 앬 앬 — 앬 앬 — 앬 앬
Side 앬 앬 — 앬 — — 앬 — — 앬
Air gripper
10-SYJ3000 — —
Bottom — — — — — — — — — —
Base mounted
Side — 앬 — 앬 앬 — 앬 앬 — 앬
Directional control
10-SYJ5000 앬 앬
앬
valve
Bottom — — — — — — — — —
Side — — 앬 — 앬 앬 — 앬 앬 —
10-SYJ7000 앬 앬
Bottom — — 앬 — — — — — —
Flow control
—
equipment
Body ported Type 21P
A, B port
P port
control equipment
Filter, Pressure
Individual SUP
R port spacer assembly
Base mounted
P port
P
Type 32P
R port
A, B port
P port
Air preparation
equipment
R1
R port
· For detailed specifications about 10-
A, B port SYJ3000, refer to page 507. For 10-
P port SYJ5000, refer to page 529, and for
10-SYJ7000, refer to page 550.
Clean gas filter
493
Series 10-SYJ3000 Rubber seal
4/5 port solenoid valve
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure range (MPa) 2 position double 0.1 to 0.7
3 position 0.2 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (with no freezing. Refer to page 714.)
Response time ms 2 position single, double 15 or less
(0.5MPa) Note 1) 3 position 30 or less
2 position single, double 10
Max. operating frequency (Hz)
3 position 3
Body ported Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
2 Note 2)
Shock/Vibration resistance m/s 150/30
Enclosure Dustproof (∗ M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature : 20°C, at rated voltage and
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000Hz. Test
was performed to axis and right angle directions of the main valve when pilot signal is ON and
Base mounted OFF. (Value in the initial state)
Solenoid specifications
JIS Symbol
5 port 4 port (For manifold
use only) Electrical entry Grommet (G)/(H), L plug connector (L),
2 position single 2 position single M plug connector (M), M8 connector (W)
(B) (A) (B)(A)
2 4 2 4 DC 24, 12, 6, 5, 3
Coil rated voltage V
AC50/60Hz 100, 110, 200, 220
3 1 5
(R) (P) (R)
1 3 Allowable voltage fluctuation ±10% of rated voltage ∗
(P) (R)
2 position double 2 position double Standard 0.35 (With indicator light: 0.4)
(B) (A) (B) (A) Power consumption (W) DC
2 4 2 4 With power saving circuit 0.1 (With indicator light only)
100 VAC 0.78 (With indicator light: 0.81)
3 1 5 110 VAC 0.86 (With indicator light: 0.89)
(R) (P) (R) 1 3
(P) (R)
Apparent power (VA) ∗ [115 VAC] [0.94(With indicator light: 0.97)]
3 position closed center 3 position closed center AC
(B) (A) (B) (A) 200 VAC 1.18 (With indicator light: 1.22)
2 4 2 4
220 VAC 1.30 (With indicator light: 1.34)
3 1 5 [230 VAC] [1.42 (With indicator light: 1.46)]
(R) (P) (R) 1 3
(P) (R) Surge voltage suppressor Diode (Non-polar type: Varistor)
3 position exhaust center 3 position exhaust center Indicator light LED
(B)(A) (B) (A)
2 4 2 4
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is -15% to +5% of rated voltage.
3 1 5
(R) (P) (R) 1 3 ∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please
(P) (R) observe the following range because they have voltage drop due to internal circuit.
3 position pressure center 3 position pressure center
(B) (A) (B) (A) S and Z types 24 VDC: -7% to +10% 12 VDC: -4% to +10%
2 4 2 4 T type 24 VDC: -8% to +10% 12 VDC: -6% to +10%
3 1 5
Bracket mounting
(R) (P)(R) 1 3
(P) (R) (1) Insert the lower hook of the mounting (2) Press the valve and mounting bracket
bracket into the groove on the bottom of together until the upper hook of the bracket
the valve as shown. snaps into place in the groove on top of the
Made to valve.
Order Made to order specifications
(Refer to page 557 for details.)
494
4/5 port solenoid valve Series 10-SYJ3000
Flow characteristics / Weight
Port size Weight (g) Note 3, 4) Flow characteristics Note 2)
Effective
Valve model Type of actuation 1, 5, 3 4, 2 L/M plug M8 area mm 2 1→4/2(P→A/B) 4/2→5/3(A/B→EA/EB)
Grommet
Air cylinder
(P, EA, EB) (A, B) connector Connector C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv
10-SYJ3143 2 Single 62(36) 63(37) 67(41) —
0.46 0.36 0.12 0.46 0.35 0.12
5 port base 10-SYJ3243 position Double 79(53) 81(55) 89(63)
mounted 10-SYJ3343 Closed center M5 x 0.8 M5 x 0.8 — 0.47 0.33 0.12 0.47 0.31 0.12
(With sub-plate) 10-SYJ3443 3 Exhaust center 82(56) 84(58) 92(66) — 0.36 0.39 0.10 0.59[0.40] 0.43[0.33] 0.16[0.11]
position
10-SYJ3543 Pressure center — 0.58[0.32] 0.42[0.33] 0.16[0.080] 0.46 0.32 0.11
10-SYJ3123 2 Single 36 37 41
Rotary actuator
10-SYJ3223 position Double 53 55 63
5 port
10-SYJ3323 Closed center M3 x 0.5 M3 x 0.5 0.9
body ported 3
10-SYJ3423
position
Exhaust center 56 58 66
10-SYJ3523 Pressure center
10-SYJ3133 2 Single 36 37 41 —
4 port base 10-SYJ3233 position Double 53 55 63
mounted
10-SYJ3333 Closed center 1/8 M5 x 0.8 —
(For manifold 3
base only)Note 1) 10-SYJ3433 position Exhaust center 56 58 66 —
Air gripper
10-SYJ3533 Pressure center —
Note 1) Dedicated for manifold base, refer to page 11 for details.
Note 2) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 3) ( ): Without sub-plate
Note 4) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the
weight of the double solenoid and 3 position types.
Directional control
valve
Flow control
equipment
control equipment
Filter, Pressure
Fittings & Tubing
Air preparation
equipment
Pressure switch
Clean gas filter
495
4/5 port solenoid valve Series SYJ3000
How to Order
Light/surge voltage suppressor Bracket
Type of actuation Nil Without light/surge voltage suppressor Nil: Without bracket F: With bracket
1 2 position single solenoid S With surge voltage suppressor
2 2 position double solenoid Z With light/surge voltage suppressor
3 3 position closed center R With surge voltage suppressor (Non-polar type)
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
5 3 position pressure center
∗ For AC voltage valves, there is no "S" option. It is -+
5 port Rated voltage Note) The double solenoid mounting bracket is supplied
unattached.
DC AC (50/60Hz) To order the double solenoid bracket for use with a
5 24 VDC 1 100 VAC single solenoid valve, order the single solenoid
valve without a bracket and double solenoid
6 12 VDC 2 200 VAC
bracket separately by specifying the part number
V 6 VDC 3 110 VAC [115 VAC] of the bracket VJ3000-13-1besides the part
S 5 VDC 4 220 VAC [230 VAC] number of the solenoid valve.
∗ For type "W첸", DC voltage [Example] 10-SYJ3123-5M-M3
R 3 VDC
(Type 20 manifold) is only available. VJ3000-13-1
Electrical entry
24, 12, 6, 5, 3 VDC 24, 12 VDC
100, 110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector M8 connector E: Push-turn locking lever type
G: Lead wire L: With lead M: With lead wire MN: Without WO: Without connector
length wire (length (length 300 mm) lead wire cable
300 mm 300 mm)
+– +–
–+
–+
H: Lead wire LN: Without LO: Without MO: Without W첸: With connector
length lead wire connector connector cable Note 1)
600 mm
–+
–+
How to Order Pilot Valve Assembly How to Order Connector Assembly for L/M Plug Connector
Air cylinder
10 V111 5 G For DC : SY100-30-4A-
Clean series
Light/Surge voltage suppressor
For 100 VAC : SY100-30-1A-
Nil Without light/surge voltage suppressor
Coil specifications S With surge voltage suppresser For 200 VAC : SY100-30-2A-
Rotary actuator
Nil Standard Z With light/surge voltage suppresser
R
T
With power saving circuit
<24, 12 VDC only> U
With surge voltage suppressor (Non-polar type)
With light/surge voltage suppressor (Non-polar type)
For other voltages of AC : SY100-30-3A-
∗ Power saving circuit ∗ For AC voltage valves, there is Without lead wire
is not available in
the case of "W첸"
no "S" option. It is already built-
in to the rectifier circuit.
(With connector and 2 of sockets only) : SY100-30-A
type. ∗ For "R" and "U", DC voltage is
only available. Lead wire length
∗ Power saving circuit is only available Nil 300mm
Air gripper
in the "Z" type. 6 600mm
10 1000mm
Rated voltage Electrical entry 15 1500mm
5 24 VDC G Grommet (Lead wire length 300 mm) 20 2000mm
6 12 VDC H Grommet (Lead wire length 600 mm) 25 2500mm
V 6 VDC L With lead wire 30 3000mm
S 5 VDC L plug 50 5000mm
LN connector Without lead wire
Directional control
R 3 VDC
1 100 VAC50/60Hz LO Without connector
2 200 VAC50/60Hz M With lead wire
valve
M plug
3
110 VAC50/60Hz
[115 VAC50/60Hz]
MN connector Without lead wire How to Order M8 Connector Cable
MO Without connector
220 VAC50/60Hz WO M8 Without connector cable
4
[230 VAC50/60Hz] W첸 Connector With connector cable Note 1) V100-49-1-
∗ For type "W첸", DC ∗ For connector cable of M8 connector,
voltage is only avail- refer to page 562.
Cable length
Flow control
equipment
able. Note 1) Be sure to enter a symbol of the
cable length in 첸 with reference 1 300mm
to page 562. 2 500mm
3 1000mm
4 2000mm
7 5000mm
control equipment
Filter, Pressure
Fittings & Tubing
Air preparation
equipment
Pressure switch
Clean gas filter
497
4/5 port solenoid valve Series 10-SYJ3000
2 position single ∗[ ]: AC
G: Approx. 300
54.4[56.6] H: Approx. 600
(Lead wire length) 28.4
32.2 2-ø3.5 22 3.2
(For mounting)
13.2 7.1
16.4
10
- +
8.2
4
A B
11.5 19.3
7 Manual override
34.7[41.7]
M3 x 0.5 2-ø1.8
(A, B port) (For manifold mounting) (Light/surge voltage suppressor)
28[35]
-+
22.1
13.5
12.6
54.4[56.6]
15
2
R P R (Bracket) 15
11
10
22.1
7 7
15 M3 x 0.5
(P, R port)
28[35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
64.3[66.5]
54.5[56.7]
63.4
56
49.5
(2)
(2)
(2)
498
4/5 port solenoid valve Series 10-SYJ3000
2 position double ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ3223-첸 H 첸첸-M3 (-F)
Air cylinder
G: Approx. 300
78.8[83.2] H: Approx. 600
34.4 (Lead wire length)
7.1
1.8
Rotary actuator
4
8.2 A B
Air gripper
Equivalent to 2-ø3.2 Bracket (Light/surge voltage suppressor)
(For mounting) (18.5)
28[35]
(18.5)
22.1
-+
13.5
12.6
15
Directional control
valve
(11.5)
10 0.5
R P R
14
Flow control
equipment
M3 x 0.5
(P, R port)
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 connector (WO):
10-SYJ3223-첸L첸첸-M3 (-F) 10-SYJ3223-첸M첸첸-M3 (-F) 10-SYJ3223-첸WO첸첸-M3 (-F)
(Lead wire length)
Approx. 300
28[35]
79[83.4]
96.8
69
82
Pressure switch
15
22.1 15
15
22.1
22.1
Clean gas filter
499
4/5 port solenoid valve Series 10-SYJ3000
3
Grommet (G), (H): 10-SYJ3 45 23-첸GH첸첸-M3 (-F)
G: Approx. 300
91.7[96.1] H: Approx. 600
40.2[42.4] (Lead wire length)
29.3 18
1.8 5.3
4
8.2
A B
28[35]
(18.5)
22.1
-+
13.5
12.6
15
(11.5)
10 0.5
R P R
14
M3 x 0.5
(P, R port)
28[35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
50.1[52.3]
40.3[42.5]
49.2
41.8
35.3
91.9[96.3]
109.7
46.6
53.1
15
22.1 15
15
22.1
22.1
500
4/5 port solenoid valve Series 10-SYJ3000
2 position single ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ3143-첸 H 첸첸-M5
Air cylinder
M5 x 0.8 10
(A, B port)
5
10
Rotary actuator
2-ø3.2 32.2
(For mounting)
22 4
2.5
Manual override
B A
11
A
B
Air gripper
G: Approx. 300 1
H: Approx. 600 54.4[56.6]
(Light/surge voltage suppressor) (Lead wire length)
Directional control
41.5[48.5]
-+
35.6
valve
28.5
26.1
R2 P R1
13
10 10 10 M5 x 0.8
17.5 (Mounting hole)
14
28
Flow control
equipment
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 Connector (WO):
10-SYJ3143-첸L첸첸-M5 10-SYJ3143-첸M첸첸-M5 10-SYJ3143-첸WO첸첸-M5
(Lead wire length)
41.5[48.5]
26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
Air preparation
equipment
64.3[66.5]
54.5[56.7]
63.4
56
49.5
R2
R2
R2
10 10
10 10
10 10
28
28
28
P
P
14
14
14
R1
R1
R1
Pressure switch
5 5 5
28.5 28.5 28.5
35.6 35.6 35.6
Clean gas filter
501
4/5 port solenoid valve Series 10-SYJ3000
2 position double ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ3243-첸 H 첸첸-M5
M5 x 0.8 10
(A, B port)
5
10
2-ø3.2
(For mounting) 22
2.5
Manual override
11
G: Approx. 300 34.4
H: Approx. 600 78.8[83.2]
(Light/surge voltage suppressor) (Lead wire length)
41.5[48.5]
35.6
26.1
13
10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)
28
41.5[48.5]
26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
98.6[103]
79[83.4]
10 10
10 10
10 10
96.8
28
28
69
28
82
14
14
14
5 5 5
502
4/5 port solenoid valve Series 10-SYJ3000
Air cylinder
M5 x 0.8
10 (A, B port)
5
10
Rotary actuator
2-ø3.2 32 15.3
(For mounting)
22 3
2.5
Manual override
B A
11
Air gripper
A
B
37.5[39.7]
G: Approx. 300
H: Approx. 600 91.7[96.1]
(Lead wire length)
(Light/surge voltage suppressor)
Directional control
41.5[48.5]
-+
valve
35.6
26.1
R2 P R1
13
10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)
Flow control
equipment
28
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 Connector (WO):
3 3 3
10-SYJ3 45 43-첸L첸첸-M5 10-SYJ3 45 43-첸M첸첸-M5 10-SYJ3 45 43-첸WO첸첸-M5첸
(Lead wire length)
Approx. 300
41.5[48.5]
R2
R2
91.9[96.3]
10 10
10 10
10 10
28
28
28
109.7
P
P
14
14
14
R1
R1
R1
5 5 5
37.6[39.8]
47.4[49.6]
32.6
Pressure switch
39.1
46.5
503
Series 10-SYJ3000 Manifold specifications
Manifold standard
Manifold specifications
Model Type 20 Type 31/S31 Type 32/S32 Type 41/S41 Type 46/S46
Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R) Effective
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C (mm2)
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
Body ported for
10-SS5YJ3-20 10-SYJ3첸23 M5 x 0.8 M3 x 0.5 — — — — — — 0.9
internal pilot
10-SS5YJ3-31-S31 10-SYJ3첸33 M5 x 0.8 M3 x 0.5 — — — — — — 0.9
10-SS5YJ3-32-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 —
10-SS5YJ3-32-C4 C4 0.25 0.18 0.059 0.30 0.27 0.075 —
10-SYJ3첸33 1/8
10-SS5YJ3-S32-M5 M5 x 0.8 0.25 0.26 0.060 0.29 0.15 0.062 —
10-SS5YJ3-S32-C4 C4 0.24 0.21 0.057 0.27 0.18 0.062 —
Base mounted for 10-SS5YJ3-41-M5 M5 x 0.8 0.32 0.25 0.081 0.33 0.19 0.079 —
internal pilot 10-SS5YJ3-41-C4 C4 0.32 0.28 0.079 0.35 0.24 0.084 —
10-SYJ3첸43 1/8
10-SS5YJ3-S41-M5 M5 x 0.8 0.33 0.29 0.082 0.34 0.17 0.081 —
10-SS5YJ3-S41-C4 C4 0.32 0.27 0.079 0.34 0.24 0.084 —
10-SS5YJ3-46-M5 M5 x 0.8 0.20 0.25 0.048 0.10 0.12 0.024 —
10-SS5YJ3-46-C4 1/8 C4 0.21 0.27 0.050 0.21 0.13 0.047 —
10-SYJ3첸43
10-SS5YJ3-S46-M5 M5 x 0.8 M5 x 0.8 0.20 0.25 0.048 0.19 0.16 0.024 —
10-SS5YJ3-S46-C4 C4 0.22 0.34 0.057 0.10 0.090 0.024 —
Note) Value at manifold base mounted, 2 position single operating
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
504
Manifold specifications 10-SYJ3000
Air cylinder
Model Type 21P Type 32P
use of the flat ribbon Manifold Single base / B mount
cable connector. P(SUP) / R(EXH) Common SUP / Common EXH
Valve stations 4 to 12 stations
• Clean appearance A, B port piping Location Valve Base
specifications Direction Top Side
Rotary actuator
In the case of a flat ribbon cable type, each valve
is wired on the print board of manifold base to P, R port 1/8
allow the external wiring to be piped all together Port size
A, B port M3 x 0.5 M5 x 0.8 C4 (One-touch fitting for ø4)
with 26 pins MIL connector.
Applicable flat ribbon
cable connector Socket: 26 pins MIL type with strain relief (conforming to MIL-C-83503)
Internal wiring In common between +COM and –COM (Z type: +COM only).
Rated voltage 12, 24 VDC, 100, 110 VAC
Note) The withstand voltage specification for the wiring unit section conforms to JIS C0704, Grade 1 or
Air gripper
its equivalent.
Flow characteristics
Directional control
Type 21P Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R) Effective
valve
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C (mm2)
port b Cv b Cv
port [dm /(s·bar)]
3 [dm /(s·bar)]
3
Body ported
for internal pilot
10-SS5YJ3-21P 10-SYJ3첸23 1/8 M3 x 0.5 — — — — — — 0.9
Base mounted 10-SS5YJ3-32P-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 —
for internal pilot 10-SS5YJ3-32P-C4
10-SYJ3첸33 1/8
C4 0.25 0.18 0.059 0.3 0.27 0.075 —
Flow control
equipment
Note) Value at manifold base mounted, 2 position single operating
control equipment
∗ 10-SYJ3133-5LOU ····3 sets (Valve) ∗ SY3000-37-28A ··3 sets (Connector assembly)
Filter, Pressure
∗ 10-SYJ3233-5LOU ····3 sets (Valve) ∗ SY3000-37-29A ··3 sets (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
2
Air preparation
505
Manifold specifications 10-SYJ3000
Common SUP / Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
P port : :
R port
M5 x 0.8 M5 x 0.8 20 20 stations
Common SUP / Individual EXH Note) For more than 10 stations, supply air to both sides of P port.
B
A, B port M5 M5 x 0.8
A, B port P port N NPT
M5 x 0.8, C4
M5 x 0.8, C4 1/8 C4 One-touch fitting for ø4 T NPTF
P port
N3 One-touch fitting for ø5/32"
1/8
506
Manifold specifications 10-SYJ3000
Common SUP / Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Air cylinder
Applicable solenoid valve
Type 21P How to Order
Refer to page 505.
A, B port
M3 x 0.5 10--SS5YJ3--21P-- 07 -- Applicable connector
P, R port assembly
Clean series thread type Refer to page 505.
Manifold stations
Rotary actuator
Nil Rc Applicable blanking
04 4 stations
00F G plate assembly
: :
P port
R port
00N NPT SYJ3000-21-3A
12 12 stations
1/8 1/8 00T NPTF (With dust cap)
Air gripper
M5 x 0.8, C4 assembly
Clean series P, R port
thread type Refer to page 505.
Manifold stations A, B port size Nil Rc Applicable blanking
04 4 stations M5 M5 x 0.8
plate assembly
F G
SYJ3000-21-4A
P port : : C4 One-touch fitting for ø4 N NPT
R port (With dust cap)
Directional control
1/8 1/8 12 12 stations N3 One-touch fitting for ø5/32" T NPTF
valve
Mixed installation of the 10-SYJ300 and the 10-SY3000 valves on the same manifold
Series 10-SYJ300 valves can be mounted on the manifolds for 10-SY3000.
Flow control
equipment
q 10-SS5YJ3-20, 10-SS5YJ3-21P (10-SYJ300 3 port valve)
The 3 port valve can be used by simply sealing off the unused "R"
port with rubber plug, SYJ3000-33-1.
Applicable solenoid valves: Type 10-SYJ312M
Type 10-SYJ322M
(10-SYJ300 3 port valve)
control equipment
Filter, Pressure
w 10-SS5YJ3-31/-S31, 10-SS5YJ3-32/-S32,
10-SS5YJ3-46/-S46, 10-SS5YJ3-32P
The 3 port valve can be used without modification. Plug (SYJ3000-33-1) Plug (SYJ3000-33-1)
The A port of the valve will flow out of the B Seal the unused "R"
Seal the unused "R"
port of the manifold. port on the end cover port on the end cover
Applicable solenoid valve: Type 10-SYJ314M side of the manifold. side of the manifold.
Type 10-SYJ324M
Caution
Mounting screw tightening torque
M1.7: 0.12N·m Type 10-SS5YJ3-20 Type 10-SS5YJ3-41
507
Manifold specifications 10-SYJ3000
<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base
5 port body ported 4 port base mounted 5 port base mounted
(Type 10-SYJ3첸23) (Type 10-SYJ3첸33) (Type 10-SYJ3첸43)
Round head combination screw
SY100-33-3
(M1.7 x 17, matt nickel plated)
Applicable manifold base Applicable manifold base Applicable manifold base
Type 10-SS5YJ3-31 Type 10-SS5YJ3-41
Type 10-SS5YJ3-20
Type 10-SS5YJ3-S31 Type 10-SS5YJ3-S41 Manifold
Type 10-SS5YJ3-21P Manifold
Type 10-SS5YJ3-32 base Type 10-SS5YJ3-46 base
Manifold base Type 10-SS5YJ3-S32 Type 10-SS5YJ3-S46
Type 10-SS5YJ3-32P
A mark A mark Protrusion for
positioning Manifold gasket
A
Manifold gasket A
Manifold gasket
SYJ3000-14-7 SYJ3000-14-6 SYJ3000-14-2
Note) Please insert the protrusion for positioning of
the manifold gasket into the hole of the valve
body completely.
Combination of blanking plate assembly and manifold base Difference between types 10-SYJ3첸33 and 10-SYJ3첸43
Blanking plate assembly Blanking plate assembly Type 10-3첸33 (4 port) Type 10-3첸43 (5 port)
SYJ3000-21-1A SYJ3000-21-2A
Round head
combination screw
Blanking plate Steel ball is driven in
Blanking plate
A mark A mark
Blanking plate
Blanking plate A mark
A mark
Manifold gasket
Manifold gasket
Caution
Mounting screw tightening torque
M1.7: 0.12N·m
Applicable base Applicable base Use caution to the assembly orientation for
Type 10-SS5YJ3-32P manifold base Type 10-SS5YJ3-21P manifold base solenoid valves, gasket and option parts.
508
Manifold specifications 10-SYJ3000
Type 20 manifold: Top ported / 10-SS5YJ3-20- Stations ∗ [ ]: AC
Approx. 300
Air cylinder
(Pitch)
P = 10.5 12.5
Manual
Rotary actuator
override
4 5
3.7
15.8
1.5
91.7[96.1]
78.8[83.2]
7 10
R
R
A A A A A
14
19.5
11 10
30.7
31.5
29
52.9[55.1]
53.7[55.9]
B B B B B
R
R
Air gripper
2-ø3.5 M5 x 0.8
(For mounting) (P, R port)
M3 x 0.5
(A, B port)
L2 3.5
Directional control
L1
valve
(Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
Flow control
42[49]
equipment
26.6
13.5
control equipment
Filter, Pressure
L plug connector (L) M plug connector (M) M8 connector (WO)
(Lead wire length)
Approx. 300
42[49]
26.6
1.5
1.5
Air preparation
111.5[115.9]
91.9[96.3]
equipment
109.7
98.6[103]
94.9
79[83.4]
96.8
82
53[55.2]
62.8[65]
54.5
61.9
Pressure switch
0.8
0.8
0.8
0.8
29
46.5
509
Manifold specifications 10-SYJ3000
Type 31 manifold: Side ported / 10-SS5YJ3-31- Stations -M3 ∗ [ ]: AC
2-ø3.5
(For mounting) Manual
override
M5 x 0.8
5.2
7.5
17.3
(P, R port)
52.2[54.4]
51.4[53.6]
3
91.7[96.1]
78.8[83.2]
78.8[83.2]
13.5
A A A A A
B B B B B
R
R
R
29.2
91.7[96.1]
R
30
29.2
25
12
25
51.4[53.6]
30
52.2[54.4]
3 13.5
B B B B B
P
P
P
P
A A A A A
17.3
7.5
5.2
-+ -+ -+ -+ -+ -+ -+
28.1
A A B B
15
15
12
12
B B A A
3
3
1 (Pitch) (Pitch) 1
13.5 P = 10.5 M3 x 0.5 M3 x 0.5 P = 10.5 14.5
(A, B port) (A, B port)
0.8
0.8
0.8
61.3[63.5]
51.5[53.7]
60.4
53
98.6[103]
111.5[115.9]
79[83.4]
91.9[96.3]
96.8
82
109.7
94.9
28
Approx. 300
43.4[47.3]
510
Manifold specifications 10-SYJ3000
C4
Type 32 manifold: Side ported / 10-SS5YJ3-32- Stations -M5, N3 첸 ∗ [ ]: AC
Air cylinder
2-ø4.5
(For mounting)
36.5
1/8
17
10
53.4[55.6]
54.2[56.4]
(P, R port)
78.8[83.2]
91.7[96.1]
31.5
3.2 31.2
R
12.5
(4.4)
B B B B B
32
17
1 16
P
P
A A A A A
7.5
Rotary actuator
15.3
(Station 1) (Station n)
L1
(Pitch) 4.5 L2
15.5 P = 10.5 (Light/surge voltage
15.5
suppressor)
(Station 1) (Station n) -+ -+
20
15
5
48.5[55.5]
B B
-+ -+
Air gripper
A A 16 P = 10.5 (A, B port)
20
15
B B
Applicable tubing O.D.:
5
Directional control
M8 x 1 53
0.8
0.8
35.5
0.8
valve
0.8
63.3[65.5]
53.5[55.7]
111.5[115.9]
62.4
98.6[103]
79[83.4]
91.9[96.3]
55
96.8
109.7
82
94.9
1
Flow control
equipment
(Lead wire length)
Approx. 300
control equipment
Filter, Pressure
Pilot valve of single solenoid valve is C4
Type S32 manifold: Side ported located on the same side of A and B ports. / 10-SS5YJ3-S32- Stations -M5, N3 첸
L1 C4 첸(With built-in One-touch fitting)
M5 L2 4 N3
override 10
15.5
34.2 0.2
91.7[96.1]
78.8[83.2]
36.5
17
56.4[58.6]
57.2[59.4]
31.5
R
A A A A A
35
B B B B B
P
P
12.5
(4.4)
2-ø4.5
Air preparation
-+ -+ -+ -+ -+
B B
20
15
5
A A
B B
20
1
5
15
M5 x 0.8 (Pitch)
Pressure switch
A A
L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5
10-SS5YJ3-32,S32- Stations -C4
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 42.5 53 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5
L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5
511
Manifold specifications 10-SYJ3000
Type 41 manifold: Side ported / 10-SS5YJ3-41- Stations -M5, C4
N3 첸 ∗ [ ]: AC
36.4
10 10
61.7[63.9]
60.9[63.1]
(P port)
21.4
78.8[83.2]
91.7[96.1]
R
39.5 B B B B B
38.7
36.5
18
4.3
21.5
R
(4.4)
P
A A A A A
3
11.5
7.8
20
15
48.5[55.5]
B B
5
-+ -+
2 One-touch fitting
33.1
(Pitch)
A A
17 P = 10.5 (A, B port)
20
15
5
35.5
0.8
0.8
0.8
70.8[73]
61[63.2]
69.9
111.5[115.9]
98.6[103]
62.5
79[83.4]
91.9[96.3]
96.8
109.7
82
94.9
(Lead wire length)
33 14.3
78.8[83.2]
1/8
10
(P port)
54.4[56.6]
A A A A A
R
55.2[57.4]
33.5
36.5
P
B B B B B
R
36.4
21.4
2-ø4.5
(4.4)
L2 4 (For mounting)
L1
(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
-+ -+ -+ -+ -+
B B
20
15
B B
20
A A
15
A A
5
2 (Pitch) 2
M5 x 0.8 (Pitch) One-touch fitting
P = 10.5 15
P = 10.5 15 (A, B port)
(A, B port)
Applicable tubing O.D.:
ø4 and ø5/32"
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
512
Manifold specifications 10-SYJ3000
Type 46 manifold: Side ported / 10-SS5YJ3-46- Stations -M5, C4
N3 첸 ∗ [ ]: AC
Approx. 300
(Lead wire length)
Grommet (G) C4 첸 (With built-in One-touch fitting)
M5 (Pitch) N3
Air cylinder
14.5 P = 10.5
1/8
10 (P port)
Manual
override
1/8
34.9
10
59.9[62.1]
60.7[62.9] (P port)
18.9
78.8[83.2]
91.7[96.1]
B B B B B
38.5
37.7
35
3.3
P
(4.4)
Rotary actuator
19
A A A A A
10
8.8
2-ø4.5
4 L2 (For mounting) (Station 1) (Station n)
L1 (Light/surge voltage suppressor)
(Station 1) (Station n)
-+ -+
(Light/surge voltage suppressor)
Air gripper
48.5[55.5]
A A
20
15
-+ -+
B B
5
33.1
Directional control
L plug connector (L) M plug connector (M) M8 connector (WO)
valve
M8 x 1 53
0.8
35.5
0.8
0.8
0.8
69.8[72]
60[62.2]
68.9
111.5[115.9]
98.6[103]
61.5
79[83.4]
91.9[96.3]
Flow control
equipment
96.8
109.7
82
94.9
(Lead wire length)
Approx. 300
control equipment
Filter, Pressure
(Lead wire length)
33
48.5[55.5]
∗ Refer to page 563 for dimensions with
connector cable.
1/8
78.8[83.2]
Air preparation
10
equipment
(P port)
A A A A A
53.9[56.1]
54.7[56.9]
25
35
P
B B B B B
34.9
18.9
2-ø4.5
(4.4)
L2 4 (For mounting)
L1
Pressure switch
-+ -+ -+ -+ -+
(Light/surge voltage suppressor) -+ -+ -+ -+ -+
B B
20
B B
20
15
15
A A
5
A A
5
(A, B port)
(A, B port) Applicable tubing O.D.:
ø4 and ø5/32"
Stations n 2 Stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Stations
L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
513
Manifold specifications 10-SYJ3000
L1
L2 4
Manual override
-+ -+ -+
M3 x 0.5 -+
(A, B port) 10
2 2
5.2
111.5[115.9]
30 17.3
7.5
7 8.5
16 3
98.6[103]
A
P
P
29.2
31.5
61.3[63.5]
62.1[64.3]
17
45.5
B
65.3
R
2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+
Triangle mark
(Pitch) 1/8
P=12.5 18.5 (P, R port)
(Station n) (Station 1)
(Light/surge voltage suppressor)
48.5[55.5]
25.6
5.8
20
28.5
B B
One-touch fitting (A, B port) P = 12.5 19.5
15
A
Applicable tubing O.D.: ø4 and ø5/32" 1
A
5
B B
15
20
A A
L1
L2 4
Manual override
-+ -+ -+
-+
10 10
3.2
32 15.3
7.5
(4.4)
111.5[115.9]
12.4
1
98.6[103]
16
A A A A A A
P
P
31.2
31.5
17
63.3[65.5]
64.1[66.3]
36.4
B B B B B B
R
R
65.3
17
50.4
70.2
2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+
Triangle mark
(Pitch) 1/8
P = 12.5 18.5 (P, R port) 1/8
(Station n) (Station 1) (P, R port)
(Light/surge voltage suppressor)
Applicable connector: 26 pins MIL type
With strain relief
48.5[55.5]
(Conforming to MIL-C-83503)
5.8
25.6
20
514
Series 10-SYJ5000 Rubber seal
5 port solenoid valve
Air cylinder
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure
2 position double 0.1 to 0.7
range MPa
3 position 0.15 to 0.7
Ambient and fluid temperature -10 to 50°C (with no freezing. Refer to page 714.)
Rotary actuator
Response time ms Note 1) 2 position single, double 25 or less
(0.5 MPa) 3 position 40 or less
Max. operating 2 position single, double 5
frequency (Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the main and pilot valve
Lubrication Not required
Body ported
Mounting orientation Unrestricted
Air gripper
Impact/Vibration resistance m/s2 Note 2) 150/30
Enclosure Dustproof (∗ DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve
and armature in both energized and de-energized states every once for each condition. (Value in the initial state)
Directional control
Vibration resistance: No malfunction occurred in one sweep between 45 and 2000Hz. Test was performed in the axial direction and at the right angles
to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state)
valve
Solenoid specifications
Grommet(G), (H) , L plug connector (L),
M plug connector (M), DIN terminal (D),
Electrical entry M8 connector (W)
Base mounted
G, H, L, M, W D
JIS Symbol DC 24, 12, 6, 5, 3 24, 12
Rated coil voltage V
Flow control
equipment
AC 50/60Hz 100, 110, 200, 220
Body ported Base mounted Allowable voltage fluctuation ±10% of rated voltage ∗
(With sub-plate)
Standard 0.35 {With indicator light: 0.4 (DIN terminal with indicator light: 0.45)}
2 position single 2 position single Power consumption (W) DC
With power saving circuit 0.1 (With indicator light only)
(A) (B) (B)(A) 100V 0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)
4 2 2 4 110V 0.86 (With indicator light: 0.89) 0.86 (With indicator light: 0.97)
[115V] [0.94 (With indicator light: 0.97)] [0.94 (With indicator light: 1.07)]
Apparent power (VA) ∗ AC
control equipment
5 1 3 200V 1.18 (With indicator light: 1.22) 1.15 (With indicator light: 1.30)
Filter, Pressure
3 1
(R1) (P) (R2) (R)(P) 220V 1.30 (With indicator light: 1.34) 1.27 (With indicator light: 1.46)
2 position double 2 position double [230V] [1.42 (With indicator light: 1.46)] [1.39 (With indicator light: 1.60)]
(A) (B) (B)(A) Surge voltage suppressor Diode (DIN terminal, varistor for non-polar types)
4 2 2 4 Indicator light LED (Neon light for DIN terminal AC)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
5 1 3 3 1 ∗ For 115 and 230 VAC, the allowable voltage fluctuation is -15% to +5% of rated voltage.
(R1) (P) (R2) (R)(P) ∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please
observe the following range because they have voltage drop due to internal circuit.
5 1 3
Built-in speed controller
(R1) (P) (R2) 3 1
(R)(P)
10-SYJ5첸53 Throttle valve characteristics ( AB →R)
앬 Built-in exhaust flow controls enable simple cylinder speed
3 position exhaust center 3 position exhaust center
adjustments.
Effective area (mm2)
(A) (B) (B)(A) 앬 When mounted on the manifold, the common exhaust discharges
Air preparation
4 2 2 4
the pilot and main valve exhaust through a common EXH port to 2
equipment
5 1 3
(Fully closed) (Fully open)
(R1) (P) (R2) 3 1
(R) (P)
How to order valve with Note) 앬 When using 10-SYJ5첸53 model, the speed controller
built-in speed controller must be opened more than 1 complete rotation from
fully closed in order to function properly.
Made to
10--SYJ5 53 -- -- 앬 Adjust the speed controller with a torque of 0.3 N·m
Order Made to order specifications or less.
Type of Port size
(Refer to page 557 for details.) actuation Plate fixing screw
Manual override
Clean gas filter
Clean series
Rated voltage Light/Surge voltage
Electrical entry suppressor
Note) Do not loosen plate fixing screw.
515
5 port solenoid valve Series 10-SYJ5000
Flow characteristics / Weight
Port size Flow characteristics Note 1) Weight (g) Note 2, 3)
Valve model Type of actuation 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
Grommet L/M plug DIN terminal M8 connector
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv connector
Single 46 47 68 51
2 position 0.47 0.41 0.13 0.47 0.41 0.13 74
Double 64 66 108
10-SYJ5첸23-첸-M5 Closed center M5 x 0.8 M5 x 0.8 0.49 0.44 0.13 0.44 0.40 0.12
3 position Exhaust center 0.46 0.37 0.12 0.47[0.39] 0.43[0.35] 0.13[0.10] 75 77 119 85
Pressure center 0.49[0.39] 0.51[0.38] 0.14[0.10] 0.45 0.42 0.12
Single 53 54 75 58
Body ported
516
5 port solenoid valve Series 10-SYJ5000
How to Order
Light/Surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Air cylinder
Type of actuation Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
S With surge voltage suppresser S With surge voltage suppressor (Non-polar type)
1 2 position single solenoid
Z With light/surge voltage suppresser Z With light/surge voltage suppressor (Non-polar type)
2 2 position double solenoid
R With surge voltage suppresser (Non-polar type) ∗ "DOZ" is not available.
3 3 position closed center
U With light/surge voltage suppresser (Non-polar type) ∗ For AC voltage valves, there is no "S" option.
4 3 position exhaust center It is already built-in to the rectifier circuit.
5 3 position pressure center ∗ For AC voltage valves, there is no "S" option.
It is already built-in to the rectifier circuit. Bracket
Rotary actuator
∗ For "R" and "U", DC voltage is only available.
∗ Power saving circuit is only available in the "Z" type. Nil: Without bracket
F: With bracket
Rated voltage
DC specifications AC specifications (50/60Hz)
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC[115 VAC] M5 M5 x 0.8
S 5 VDC 4 220 VAC[230 VAC] C4 One-touch fitting for ø4
Air gripper
R 3 VDC ∗ For type "W첸", DC C6 One-touch fitting for ø6
∗ DC specifications voltage is only N3 One-touch fitting for ø5/32"
of type "D" and "DO" available. N7 One-touch fitting for ø1/4"
is only available with Note) The mounting bracket is
(For manifold type 20) 12 and 24 VDC. supplied unattached.
Directional control
Body ported 10 SYJ5 1 23 5 L M5
valve
Base mounted 10 SYJ5 2 43 5 L
Thread type
Clean series
Flow control
equipment
Nil Rc
Coil specifications Manual override F G
Nil Standard N NPT
Nil: Non-locking push type
With power saving circuit T NPTF
T
<For 24 and 12 VDC only>
∗ Power saving circuit is not
Port size
control equipment
Sub-plate, 40, 41, 42,
available in the case of "D",
Filter, Pressure
43 manifold
"DO" or "W첸" type. Nil: Without sub-plate
D: Push-turn locking
slotted type
G: Lead wire length L: With lead wire M: With lead wire MN: Without lead wire D: With connector WO: Without connector lever type
equipment
–+
–+
Pressure switch
H: Lead wire length LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector W첸: With connector
600 mm cable Note 1)
–+
Clean gas filter
–+
517
5 port solenoid valve Series 10-SYJ5000
How to Order Pilot Valve Assembly How to Order Connector Assembly for L/M Plug Connector
518
5 port solenoid valve Series 10-SYJ5000
2 position single ∗ [ ]: AC
G
Grommet (G), (H):10- SYJ5123-첸 첸첸-M5 H With bracket
G
10-SYJ5123-첸 H 첸첸-M5-F
Air cylinder
37
G: Approx. 300
63.1[65.3] H: Approx. 600 2-ø3.5 30 3.5
(Lead wire length) (For mounting)
41
19.5
18
25
-+
Rotary actuator
11
19.7
5
A B
35.1[42.1]
M5 x 0.8 10 Manual override
(A, B port) 19 2-ø2.6
(For manifold mounting)
63.1[65.3]
2-M3 x 0.5 (Light/surge voltage suppressor)
Air gripper
(Mounting screw)
-+
18
23
20
(Bracket)
2.3
28.1[35.1]
2.5
12.7
10.6 11 2-ø2.6 Built-in One-touch Fitting:
Directional control
3.5 4 (For mounting) G C4,N3
10-SYJ5123-첸 H 첸첸- C6,N7 (-F)
valve
19.5
3.5
A B
R1 P
16
15
Flow control
M5 x 0.8 21 (3.2)
equipment
(A, B port)
(P, R1, R2 port) Applicable tubing O.D.: ø4 and ø5/32"
: ø6, ø1/4"
32.3
control equipment
(2.3)
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5123-첸L첸첸-M5(-F) 10-SYJ5123-첸M첸첸-M5(-F) 10-SYJ5123-첸D첸첸-M5(-F) 10-SYJ5123-첸WO첸첸-M5(-F)
ø3.5 to ø7
MAX.10
28.1[35.1] 60.9
53.4
12.7
42.1
M8 x 1 32.6
Air preparation
15.1
equipment
63.2[65.4]
82.1
83
72.1
58.2
64.7
3 3 3 3
42.2
Pressure switch
19.5
19.5
19.5
11
11
11
19.5
11
(2.3)
(2.3)
20 2-ø2.6
(2.3)
519
5 port solenoid valve Series 10-SYJ5000
2 position double ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ5223-첸 H 첸첸-M5 Built-in One-touch fitting
10-SYJ5223-첸 GH 첸첸-C4,N3
C6,N7
G: Approx. 300
87.2[91.6] H: Approx. 600
43 (Lead wire length)
3.5
11
5
A B A B
One-touch fitting
(3.2)
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D.: ø4 and ø5/32"
: ø6, ø1/4"
32.3
-+
23
20
12.7
28.1[35.1]
3
11 2-ø2.6
(For mounting)
R1 P
15
R2
M5 x 0.8 21
(P, R1, R2 port)
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5223-첸L첸첸-M5 10-SYJ5223-첸M첸첸-M5 10-SYJ5223-첸D첸첸-M5 10-SYJ5223-첸WO첸첸-M5
(Lead wire length)
ø3.5 to ø7
MAX.10
28.1[35.1] 60.9
12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2[46.2]
(Lead wire length)
Pg7
20 20 20 20
107[111.4]
3 3 3
87.4[91.8]
3
105.2
125.2
90.4
77.4
45.4
127
11
11
11
11
23
2-ø2.6 2-ø2.6 2-ø2.6
(For mounting) (For mounting) (For mounting)
23
23
23
27
2-ø2.6
(For mounting)
520
5 port solenoid valve Series 10-SYJ5000
3 position closed center / exhaust center / pressure center ∗ [ ]: AC
3
Grommet (G), (H): 10-SYJ5 45 23-첸GH 첸첸-M5 Built-in One-touch fitting:
3
10-SYJ5 45 23-첸GH 첸첸- C4,N3
Air cylinder
C6,N7
G: Approx. 300
103.2[107.6] H: Approx. 600
44.2[46.4] (Lead wire length)
36.9 22.1 44.2[46.4]
3.5
11
5
Rotary actuator
A B A B
One-touch fitting
(3.2)
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D: ø4 and
Air gripper
ø5/32"
32.3
: ø6, ø1/4"
-+
23
20
12.7
28.1[35.1]
3
11 2-ø2.6
(For mounting)
Directional control
valve
R1 P
15
R2
M5 x 0.8 21
(P, R1, R2 port)
Flow control
equipment
control equipment
Filter, Pressure
L plug connector
3
(L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3
10-SYJ5 5 23-첸L첸첸-M5
4 10-SYJ5 45 23-첸M첸첸-M5 10-SYJ5 45 23-첸D첸첸-M5 10-SYJ5 45 23-첸WO첸첸-M5
(Lead wire length)
28.1[35.1] 60.9
12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2[46.2]
(Lead wire length)
Air preparation
Pg7
equipment
54.1[56.3]
44.3[46.5]
64.1
63.2
53.2
45.8
39.3
20 20 20 20
23.3
3 3 3 3
103.4[107.8]
123[127.4]
11
11
11
141.2
121.2
143
11
38.1
23 2-ø2.6 23 2-ø2.6 23 23
Pressure switch
54.1
60.6
27
Clean gas filter
521
5 port solenoid valve Series 10-SYJ5000
2 position single ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ5143-첸 H 첸첸-01첸 Built-in speed controller:
G
10-SYJ5153-첸 H 첸첸-01첸
MAX.13.5
1/8 19.4 10.3
17 11.5
(A, B port)
8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24
B
R P
-+
45
8.5
34.7
21.5
15 17 17
24 1/8 45.5
32 (P, R port)
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5143-첸L첸첸-01첸 10-SYJ5143-첸M첸첸-01첸 10-SYJ5143-첸D첸첸-01첸 10-SYJ5143-첸WO첸첸-01첸
(Lead wire length)
ø3.5 to ø7
82.9
MAX.10
50.1[57.1] 75.4
34.7 64.1
49 54.6 M8 x 1
37.1
61.2[68.2] Approx. 300
(Lead wire length) Pg7
6 6 6 6
73.5[75.7]
63.7[65.9]
83.5
82.6
65.2
72.6
58.7
45.5
45.5
45.5
45.5
17 17
17 17
17 17
17 17
42.7
0.5
0.5
0.5
6 6 6 6
0.5
522
5 port solenoid valve Series 10-SYJ5000
2 position double ∗ [ ]: AC
Air cylinder
1/8 17 11.5
(A, B port)
MAX.13.5
8.5
19.4 10.3
Rotary actuator
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24
B
Air gripper
R P
41.5 1.5
G: Approx. 300 23.6[25.8]
H: Approx. 600 87.2[91.6]
(Lead wire length)
Directional control
(Light/surge voltage suppressor)
valve
50.1[57.1]
-+
45
34.7
8.5
21.5
Flow control
15 17 17
equipment
24 1/8 45.5
32 (P, R port)
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5243-첸L첸첸-01첸 10-SYJ5243-첸M첸첸-01첸 10-SYJ5243-첸D첸첸-01첸 10-SYJ5243-첸WO첸첸-01첸
ø3.5 to ø7
Approx. 300
82.9
MAX.10
50.1[57.1] 75.4
34.7 64.1
49 54.6
M8 x 1
61.2[68.2] Approx. 300 37.1
Air preparation
equipment
65.2
87.4[91.8]
58.7
45.5
45.5
45.5
45.5
125.2
105.2
17 17
17 17
17 17
17 17
42.7
127
2.7
Pressure switch
18.7
6 6 6 6
25.2
32.6
42.6
8.5
21.5
23.7[25.9]
523
5 port solenoid valve Series 10-SYJ5000
1/8 17 11.5
MAX.13.5
(A, B port)
19.4 10.3
8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24
B
R P
42.1 16.9
39[41.2]
G: Approx. 300
H: Approx. 600 103.2[107.6]
(Lead wire length)
-+
45
34.7
21.5
15 17 17
8.5
1/8
24 45.5
(P, R port)
32
L plug connector
3
(L): M plug connector
3
(M): DIN Terminal
3
(D): M8 connector
3
(WO):
10-SYJ5 45 43-첸L첸첸-01첸 10-SYJ5 45 43-첸M첸첸-01첸 10-SYJ5 45 43-첸D첸첸-01첸 10-SYJ5 45 43-첸WO첸첸-01첸
Applicable cable O.D.
(Lead wire length)
ø3.5 to ø7
Approx. 300
82.9
MAX.10
50.1[57.1] 75.4
64.1
34.7
49 54.6 M8 x 1
61.2[68.2] Approx. 300 37.1
(Lead wire length) Pg7
6 6 6 6
65.8
59.3
103.4[107.8]
123[127.4]
45.5
45.5
45.5
45.5
43.3
17 17
17 17
17 17
17 17
141.2
121.2
143
18.1
6 6 6 6
48.9[51.1]
34.1
40.6
58
524
Series10-SYJ5000 Manifold specifications
Air cylinder
Manifold standard
Manifold specifications
Rotary actuator
Manifold type Single base / B mount
Air gripper
P, R port 1/8 1/4 1/8
Port size M5 x 0.8 1/8, C6
C4 (One-touch
A, B port C4 (One-touch fitting for ø4) M5 x 0.8 (One-touch
C6 (One-touch fitting for ø6) fitting for ø6) fitting for ø4)
Directional control
Flow characteristics
valve
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3(A/B→R)
Manifold model
1(P), 5/3(R) 2(B), 4(A) C C
port port [dm3/(s·bar)] b Cv [dm3/(s·bar)] b Cv
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
10- SS5YJ5-20 10-SYJ5첸23 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
for internal pilot
Flow control
equipment
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
10-SS5YJ5-40 1/8 M5 x 0.8 0.55 0.35 0.15 0.64 0.26 0.16
10-SS5YJ5-41 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
Base mounted
10-SS5YJ5-42-01 10-SYJ5첸43 1/4 1/8 0.74 0.22 0.18 0.82 0.31 0.21
for internal pilot
10-SS5YJ5-42-C6 1/4 C6 0.71 0.24 0.17 0.8 0.29 0.20
10-SS5YJ5-43 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
control equipment
Note) Value at manifold base mounted, 2 position single operating
Filter, Pressure
How to Order Manifold (Example)
525
Manifold specifications 10-SYJ5000
Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
10-SS5YJ5-20P 10-SYJ5첸23 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
for internal pilot
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
Base mounted 10-SS5YJ5-41P 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
10-SYJ5첸43
for internal pilot 10-SS5YJ5-43P 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
Note) Value at manifold base mounted, 2 position single operating
526
Manifold specifications 10-SYJ5000
Common SUP / Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Air cylinder
M5 x 0.8 Applicable blanking
Clean series plate assembly
-+ P, R port
-+
P port Number of stations thread type SYJ5000-21-4A
1/8 02 2 stations Applicable individual
R
Nil Rc
P
R
: : 00F G EXH spacer assembly
R port 20 20 stations 00N NPT SYJ5000-17-1A
Rotary actuator
1/8 00T NPTF
Air gripper
02 2 stations Nil Rc Applicable individual
: : F G EXH spacer assembly
R port
20 20 stations N NPT SYJ5000-17-1A
A, B port 1/8
T NPTF
M5 x 0.8 A, B port size
M5 M5 x 0.8
Directional control
valve
Type 41 (5 port / base mounted) How to Order
10 SS5YJ5 41 05 M5
Clean series
Number of stations
Flow control
equipment
-+
-+ 02 2 stations P, R port
R port thread type
: :
R
1/8 Nil Rc
P
A, B port 20 20 stations
F G
M5 x 0.8 P port
A, B port size N NPT
1/8
M5 M5 x 0.8 T NPTF
control equipment
Filter, Pressure
Type 42 (5 port / base mounted) How to Order
Applicable solenoid valve
10 SS5YJ5 42 05 C6 10-SYJ5첸43-첸첸첸첸
Clean series 10-SYJ5첸53-첸첸첸첸
Number of stations Applicable blanking
-+ 02 2 stations plate assembly
-+
1/4
A Thread type
A, B port size EXH spacer assembly
A, B port B Nil Rc
P port
01 1/8
SYJ5000-17-1A
1/8, C6 F G
1/4
C6 One-touch fitting for ø6
Applicable individual
N NPT
SUP spacer assembly
N7 One-touch fitting for ø1/4" T NPTF
SYJ5000-16-2A
Air preparation
10 SS5YJ5 43 05 C4
Clean series
Manifold stations
-+
-+ 02 2 stations
Pressure switch
R port : : P, R port
R
thread type
P
1/8
A, B port A 20 20 stations
B Nil Rc
C4 P port
A, B port size F G
1/8
C4 One-touch fitting for ø4 N NPT
N3 One-touch fitting for ø5/32" T NPTF
Clean gas filter
527
Manifold specifications 10-SYJ5000
Flat ribbon cable manifold
Common SUP / Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Type 20P (5 port / body ported) How to Order Applicable solenoid valve
Refer to page 526.
A, B port
10 SS5YJ5 20P-- 05
Applicable blanking
P port Clean series P, R port plate assembly
1/8 thread type SYJ5000-21-3A
Number of stations
Nil Rc
03 3 stations
00F G Applicable connector
: : assembly
R port 00N NPT
1/8 12 12 stations 00T NPTF Refer to page 526.
<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base
Round head combination screw Round head combination screw
M2.5 x 25 M2.5 x 25
Matt nickel plated Matt nickel plated
(With spring washer) (With spring washer)
Blanking plate
Blanking plate
Gasket Gasket
Caution
Applicable base Mounting screw tightening torque
· 10-SS5YJ5-20
M2.5: 0.45N·m
· 10-SS5YJ5-40 Dust cap Applicable base
· 10-SS5YJ5-41 · 10-SS5YJ5-20P Use caution to the assembly
· 10-SS5YJ5-42 orientation for solenoid valve,
· 10-SS5YJ5-41P
· 10-SS5YJ5-43
gasket, and optional parts.
· 10-SS5YJ5-43P
528
Manifold specifications 10-SYJ5000
<Manifold option>
Mix installation of the 10-SYJ500 and the 10-SYJ5000 valves on the same manifold
앬 Use of an adapter plate makes it possible to mount Series 10-SYJ500 on the manifold bases of series 10-SYJ5000.
Air cylinder
앬 When mounting the 10-SYJ500 valve on the 10-SYJ5000 manifold, the 10-SYJ500 solenoid must be positioned on the same side of the manifold as a single solenoid of 10-SYJ5000.
앬 For base mounted style, the A port of the 3 port valve flows out the B port of manifold base.
Rotary actuator
Round head combination screw
Gasket
Air gripper
Round head combination screw
Round head combination screw
Adaptor plate
7
Adaptor plate
7
Adaptor gasket
Directional control
valve
Adaptor gasket Applicable base
· 10-SS5YJ5-40
Applicable base · 10-SS5YJ5-41
· 10-SS5YJ5-20 · 10-SS5YJ5-42
· 10-SS5YJ5-43
Flow control
equipment
SYJ5000-17-1A
SYJ5000-16-2 A
Round head combination screw Round head combination screw
Thread type
Nil Rc
control equipment
Filter, Pressure
F G
N NPT
T NPTF
B
A
A
Manifold gasket
Manifold gasket
15
529
Manifold specifications 10-SYJ5000
Type 20: Top ported / 10-SS5YJ5-20- Station -00첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
(DIN: 14.6)
(Pitch)
16.515.2
(DIN: 46.2)
(DIN: 46.8)
23.5
87.2[91.6]
16.516.5
R
R
A
A
45.6
67.1[69.3]
67.7[69.9]
45
49
P
P
B
B
R
4-ø4.5 1/8
(For mounting) (P, R port)
M5 x 0.8
Manual override L2 9 (A, B port)
L1
Built-in One-touch fitting
(Station n) (Station 1)
-+ -+ -+ -+ -+
33.2
20
(3.2) 52.8
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
Approx. 300
MAX.10
87.4[91.8]
141.2
121.2
106.4
143
125.2
105.2
67.2[69.4]
90.4
127
77[79.2]
68.7
76.1
86.1
87
0.6
0.6
35.6
0.6
0.6
33.2
53.1
0.6
0.6
48.6[55.6] 62.6
73.9
81.4
530
Manifold specifications 10-SYJ5000
Type 40: Bottom ported / 10-SS5YJ5-40- Stations -M5첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
Air cylinder
L1
L2 9
4-ø4.5
(For mounting)
Rotary actuator
13
8.5
(DIN: 23.3) (DIN: 38.1)
16.5
43.6[45.8] 23.5
22.1 36.9
21.5 21.5
R
A A A A A
87.2[91.6]
33
47
P
P
44.2[46.4]
B B B B B
R
2.5
Air gripper
1/8
(Pitch) (P, R port)
P = 16 21 Manual override
(Station n) (Station 1)
Directional control
-+ -+ -+ -+ -+
33.2
valve
20
M5 x 0.8
(A, B port)
Flow control
equipment
12
24
MAX.13.5 43.5
control equipment
(Pitch)
Filter, Pressure
P = 16 23
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
Approx. 300
MAX.10
equipment
123[127.4]
107[111.4]
87.4[91.8]
141.2
121.2
106.4
143
125.2
105.2
90.4
127
43.7[45.9]
53.5[55.7]
45.2
52.6
62.6
63.5
Pressure switch
0.6
0.6
35.6
0.6
0.6
33.2
53.1
0.6
62.6
0.6
48.6[55.6]
73.9
81.4
Clean gas filter
531
Manifold specifications 10-SYJ5000
Type 41: Side ported / 10-SS5YJ5-41- Stations -M5첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
L1
4.5 L2 Manual override
2-ø5.5
(For mounting)
12
60.2[62.4]
59.6[61.8]
(DIN: 38.7)
(DIN: 22.1) (DIN: 39.3)
87.2[91.6]
103.2[107.6]
R
B B B B B
38.1
21
35
5.5 37.5
3.5 17.5
P
A A A A A
7
20.9
(Pitch)
18 P = 16
-+ -+ -+
37.2
A A
18.5
24
B B
5.5
(Pitch)
23 P = 16
M5 x 0.8
(A, B port)
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
85.4
77.9
52.6[59.6] 66.6
0.6
M8 x 1
0.6
57.1
37.2
0.6
39.6
0.6
0.6
0.6
69.5[71.7]
59.7[61.9]
79.5
78.6
68.6
61.2
107[111.4]
87.4[91.8]
103.4[107.8]
123[127.4]
125.2
105.2
127
90.4
141.2
121.2
106.4
143
3.5
3.5
3.5
3.5
Pg7
MAX.10
(Lead wire length)
ø3.5 to ø7
532
Manifold specifications 10-SYJ5000
Type 42: Side ported / 10-SS5YJ5-42- Stations -01, C6
N7 첸 ∗ [ ]: AC
Grommet (G) C6
01첸 N7 첸(With built-in One-touch fitting)
Air cylinder
(Lead wire length)
Approx. 300
L1 Manual override
6.5 L2
2-ø6.5
Rotary actuator
(For mounting)
17.5 17.5
65.2[67.4]
64.6[66.8]
(DIN: 43.7)
(DIN: 44.3)
87.2[91.6]
103.2[107.6]
B B B B B
43.9
24
24
44
0.5 42.5
43.1
23
P
A A A A A
10.4
(DIN: 1.7)
10.5
Air gripper
15.9
(DIN: 17.1)
1/4 1/4
(Pitch) (P, R port)
24.5 P = 17 (P, R port)
(Station 1) (Station n)
Directional control
(Station 1) (Station n)
(Light/surge voltage suppressor) Built-in speed controller (Light/surge voltage suppressor)
valve
MAX.13.5 56.5
61.6[68.6]
61.6[68.6]
-+ -+ -+ -+ -+ -+
46.2
46.2
A A A A
33
33
24.5
25
B B B B
6 1
8.5
8.5
Flow control
equipment
(Pitch) (Pitch)
24.5 P = 17 1/8 29 P = 16 One-touch fitting
(A, B port) (A, B port)
Applicable tubing
O.D.: ø6,ø1/4"
control equipment
Filter, Pressure
∗ Other dimensions are the same as the grommet type.
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
94.4
75.6
46.2
0.6
0.6
48.6 0.6
0.6
74.5[76.7]
64.7[66.9]
84.5
83.6
73.6
107[111.4]
87.4[91.8]
103.4[107.8]
66.2
123[127.4]
125.2
105.2
90.4
127
141.2
121.2
106.4
143
Air preparation
equipment
MAX.10
Pg7
Pressure switch
ø3.5 to ø7
533
Manifold specifications 10-SYJ5000
C4
Type 43: Side ported / 10-SS5YJ5-43- Stations - N3 첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
L1
4.5 L2 Manual override
2-ø5.5
(For mounting)
12 1/8
(P, R port)
62.6[64.8]
62[64.2]
(DIN: 4.3) (DIN: 41.1)
(DIN: 41.7)
87.2[91.6]
103.2[107.6]
R
B B B B B
40.5
17.5
36.9
3.1 39.9
1.1 20.2
P
P
A A A A A
11.4
(4.4)
18.5
(DIN: 19.7)
(Pitch)
18 P = 16
-+ -+ -+
37.2
A A
24
18
B B
6
(Pitch)
22.3 P = 16 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4,ø5/32"
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
85.4
52.6[59.6] 77.9
66.6 M8 x 1 57.1
0.6
0.6
37.2
39.6
0.6
0.6
0.6
0.6
72[74.2]
62.2[64.4]
81.1
82
63.7
71.1
125.2
90.4
127
107[111.4]
141.2
106.4
87.4[91.8]
105.2
143
123[127.4]
103.4[107.8]
121.2
1
Pg7
MAX.10
ø3.5 to ø7
534
Manifold specifications 10-SYJ5000
Air cylinder
C4, N3
Manual override C6, N7
L1
M5 x 0.8 L2 9 (With built-in One-touch fitting)
Rotary actuator
(A, B port) 4-ø4.5
-+
(For mounting)
13.4
-+ -+
15.2
2
123[127.4]
107[111.4]
10 18.5
23.5
R
R One-touch fitting
16.5 16.5
A
A
45.6
(A, B port)
77.6 [79.8]
45
49
77 [79.2]
P
Applicable tubing
65
82.8
16.5
B
Air gripper
R
ø6, ø1/4"
-+ -+ -+ -+ -+
Triangle mark
1/8 (3.2) 52.8
(Pitch)
P = 17.5 21 (P, R port)
Directional control
(Station n) (Station 1)
(Light/surge voltage suppressor)
valve
48.6[55.6]
5.8
25.1
20
Flow control
26 pins MIL type with strain relief Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations
equipment
(Conforming to MIL-C-83503) L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 59 76.5 94 111.5 129 146.5 164 181.5 199 216.5
control equipment
M5 x 0.8
Filter, Pressure
5.5
P = 17.5 26
(A, B port)
18.5
-+ -+
5.5
3.5
38.1 20.9
12
123[127.4]
7
107[111.4]
17.5
A A A A A
Air preparation
5.5
37.5
equipment
69.5 [71.7]
70.1 [72.3]
21
35
51
MAX.13.5
68.8
B B B B B
-+ -+ -+ -+ -+
P = 17.5 21
(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6[59.6]
7.8
29.1
535
Manifold specifications 10-SYJ5000
C4
10-SS5YJ5-43P- Stations - N3 첸
One-touch fitting (Pitch)
(A, B port) P = 17.5 25.3
6
Applicable tubing
O.D.: ø4, ø5/32"
18
L1 Built-in speed controller
Manual override L2 7.5
-+
-+ -+
(4.4)
11.4
12
3.1
1.1
40.5 18.5
123 [127.4]
107 [111.4]
20.2
A A A A A
5.5
36.9
39.9
17.5
71.9 [74.1]
72.5 [74.7]
52.9
MAX.13.5
70.7
B B B B B
-+ -+ -+ -+ -+
(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6 [59.6]
7.8
29.1
24
536
Series10-SYJ7000
Rubber seal
5 port solenoid valve
Air cylinder
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure
2 position double 0.1 to 0.7
range (MPa)
3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (with no freezing. Refer to page 714.)
Rotary actuator
Response time ms 2 position single, double 30 or less
(0.5MPa) Note 1) 3 position 60 or less
Max. operating 2 position single, double 5
frequency (Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the pilot and main valve
Body ported Lubrication Not required
Mounting orientation Unrestricted
Air gripper
Impact/Vibration resistance m/s2 Note 2) 150/30
Enclosure Dustproof (∗DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature : 20°C, at rated voltage,
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
Directional control
and at the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep between 45 and 2000Hz. Test was
valve
performed in the axial direction and at the right angles to the main valve and armature in both
energized and de-energized states every once for each condition. (Value in the initial state)
Base mounted
Solenoid specifications
Flow control
equipment
JIS Symbol
Body ported Base mounted Grommet (G), (H)
2 position single 2 position single solenoid
L plug connector (L)
M plug connector (M)
(A)(B) (B)(A) Electrical entry
4 2 2 4 DIN terminal (D)
M8 connector (W)
control equipment
Filter, Pressure
5 1 3 3 1 5 G, H, L, M, W D
(R1) (P) (R2) (R2) (P) (R1)
DC 24, 12, 6, 5, 3 24, 12
Coil rated voltage V
2 position double 2 position double solenoid AC 50/60Hz 100, 110, 200, 220
(A)(B) (B)(A) Allowable voltage fluctuation ±10% of rated voltage ∗
4 2 2 4
Standard 0.35 {With indicator light: 0.4 (DIN connector with indicator light: 0.45)}
Power consumption (W) DC
With power saving circuit 0.1 (With indicator light only)
5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1) 100V 0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)
4 2 2 4
equipment
∗ For 115 and 230 VAC, the allowable voltage fluctuation is -15% to +5% of rated voltage.
∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please observe the
5 1 3 3 1 5 following range because they have voltage drop due to internal circuit.
(R1) (P) (R2) (R2) (P) (R1) S and Z types 24 VDC: –7% to +10%
12 VDC: –4% to +10%
3 position pressure center 3 position pressure center T type 24 VDC: –8% to +10%
(A)(B) (B)(A) 12 VDC: –6% to +10%
4 2 2 4
Pressure switch
5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1)
Made to
Order Made to order specifications (Refer to page 557 for details.)
Clean gas filter
537
5 port solenoid valve Series 10-SYJ7000
3 position Exhaust center 1.2 0.48 0.35 3.4[1.3] 0.36[0.57] 0.86[0.41] 188(108) 190(110) 232(152) 198(118)
Pressure center 3.3[0.85] 0.43[0.54] 0.78[0.25] 2.1 0.45 0.56
Single 165(85) 166(86) 187(107) 170(90)
2 position 2.3 0.41 0.61 2.9 0.35 0.74
Double 178(98) 180(100) 222(142) 188(108)
10-SYJ7첸43-첸-02 Closed center 1/4 1/4 1.9 0.46 0.50 2.2 0.44 0.60
3 position Exhaust center 1.3 0.45 0.35 3.7[1.4] 0.27[0.56] 0.87[0.43] 188(108) 190(110) 232(152) 198(118)
Pressure center 3.6[0.83] 0.23[0.55] 0.84[0.25] 2.1 0.47 0.58
Note 1) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate
Note 3) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types.
538
5 port solenoid valve Series 10-SYJ7000
How to Order
Light/Surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Type of actuation
Air cylinder
Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
1 2 position single solenoid S With surge voltage suppresser S With surge voltage suppresser (Non-polar type)
2 2 position double solenoid Z With light/surge voltage suppresser Z With light/surge voltage suppresser (Non-polar type)
3 3 position closed center R With surge voltage suppressor (Non-polar type) ∗ "DOZ" is not available.
∗ For AC voltage valves, there is
Bracket
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
no "S" option. It is already built-
5 3 position pressure center ∗ For AC voltage valves, there is no "S" option. It is Nil: Without bracket
in to the rectifier circuit.
already built-in to the rectifier circuit. F: With bracket
Rotary actuator
∗ For "R" and "U", DC voltage is only available.
∗ Power saving circuit is only available in the "Z" Thread type
type.
Nil Rc
F G
Rated voltage
N NPT
DC specifications AC specifications (50/60Hz)
T NPTF
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC [115 VAC] 01 1/8
Air gripper
Note) Do not remove the factory
S 5 VDC 4 220 VAC [230 VAC] C6 One-touch fitting for ø6 installed bracket from
R 3 VDC ∗ For type "W첸", C8 One-touch fitting for ø8 models with the bracket
∗ DC specifications of option. Removal of the
DC voltage is N7 One-touch fitting for ø1/4" bracket will cause the
type "D" and "DO" is only available.
only available with N9 One-touch fitting for ø5/16" valve to leak. Brackets
(For manifold type 20, 21) 12 and 24 V DC. cannot be retrofitted.
Directional control
Body ported 10 SYJ7 1 23 5 M 01
valve
Base mounted 10 SYJ7 2 43 5 M
Flow control
Thread type
equipment
Nil Rc
Coil specifications Manual override F G
Nil Standard N NPT
Nil: Non-locking push
With power saving circuit type T NPTF
T
<For 24 and 12 VDC only>
control equipment
∗ Power saving circuit is
Filter, Pressure
Sub-plate, 40, 41, 42
not available in the
manifold Port size
case of "D", "DO" or
"W첸" type. Nil: Without sub-plate
D: Push-turn locking
slotted type
G: Lead wire L: With lead M: With lead wire MN: Without D: With connector WO: Without
equipment
length wire (length (length 300 mm) lead wire connector lever type
300 mm 300 mm)
+- +-
Pressure switch
H: Lead wire LN: Without LO: Without MO: Without DO: Without W첸: With connector
length 600 mm lead wire connector connector connector cable Note 1)
539
5 port solenoid valve Series 10-SYJ7000
10 V111 5 G 10 V115 5 D
Clean series Clean series
Light/Surge voltage suppressor
Coil specifications Without light/surge voltage suppressor
Rated voltage
Nil
Nil Standard 5 24 VDC
S With surge voltage suppressor
With power saving circuit 6 12 VDC
T Z With light/surge voltage suppressor Light/surge voltage suppressor
<24 and 12 VDC only> 1 100 VAC 50/60Hz
R With surge voltage suppressor (Non-polar type) 2 200 VAC 50/60Hz Nil Without light/surge voltage suppressor
∗ Power saving circuit is U With light/surge voltage suppressor (Non-polar type) 110 VAC 50/60Hz S With surge voltage suppressor (Non-polar type)
not available in the 3
∗ For AC voltage valves, there is no [115 VAC 50/60Hz] Z With light/surge voltage suppressor (Non-polar type)
case of "W첸" type.
"S" option. It is already built-in to 4 220 VAC 50/60Hz ∗ "DOZ" is not available.
the rectifier circuit. [230 VAC 50/60Hz] ∗ For AC voltage valves, there
Rated voltage ∗ For "R" and "U", DC voltage is only is no "S" option. It is already
5 24 VDC available. built-in to the rectifier circuit.
∗ Power saving circuit is only available
6 12 VDC
in the "Z" type.
V 6 VDC
S 5 VDC
R 3 VDC Electrical entry Electrical entry
1 100 VAC 50/60Hz G Grommet (Lead wire length 300 mm) D With connector
DIN
2 200 VAC 50/60Hz H Grommet (Lead wire length 600 mm) DO terminal Without connector
110 VAC 50/60Hz L With lead wire
3 Note) Do not replace 10-V111
[115 VAC 50/60Hz] L plug
LN
connector Without lead wire (G, H, L, M, W) to 10-
220 VAC 50/60Hz LO Without connector V115 (DIN terminal) and
4
[230 VAC 50/60Hz] M With lead wire vice versa when
∗ For type "W첸", DC M plug replacing pilot valve
MN
voltage is only connector Without lead wire Note 1) Be sure to enter a assembly only.
MO Without connector symbol of the cable
available.
WO M8 Without connector cable length with reference
W첸 connector With connector cable Note 1) to page 562.
∗ For connector cable of M8
connector, refer to page 562.
How to Order L/M Plug Connector Assembly How to Order M8 Connector Cable
For DC :SY100-30-4A-
V100-49-1-
For 100 VAC :SY100-30-1A-
For 200 VAC :SY100-30-2A- Cable length
1 300mm
For other voltages of AC :SY100-30-3A- 2 500mm
3 1000mm
Without lead wire 4 2000mm
(With connector and 2 of sockets only) :SY100-30-A 7 5000mm
540
5 port solenoid valve Series 10-SYJ7000
2 position single ∗ [ ]: AC
Air cylinder
44
2-ø4.5 36 4
(For mounting)
26
34
- +
G: Approx. 300
82[84.2] H: Approx. 600
Rotary actuator
59.8 (Lead wire length) 24.1
28.3 39.5[46.5]
13
3
A B
Manual override
2-ø3.2 17
(For manifold mounting) 1/8
85.6[87.8]
35 (A, B port)
Air gripper
2-ø3.2 (Light/surge voltage suppressor)
35
(For mounting) (Bracket)
3.6
-+
28
25
16.1
21
Directional control
31.5[38.5]
valve
Built-in One-touch fitting:
10-SYJ7123-첸GH 첸첸- C6, N7
C8, N9 첸 (-F)
R1 P R2
28.3
1.6
18
1/8 27.2 A B
(P, R1, R2 port)
Flow control
equipment
17
One-touch fitting
(4.9)
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
: ø8, ø5/16"
control equipment
36
Filter, Pressure
(3.6)
L plug connector (L) M plug connector (M) DIN Terminal (D): M8 connector (WO):
ø3.5 to ø7
65
31.5[38.5]
MAX.10
57.5
16.1 46.2
31.1 M8 x 1 36
Air preparation
equipment
Pg7
91.9[94.1]
101.9
82.1[84.3]
101
Pressure switch
91
83.6
77.1
61.1
35
35
35
35
28.3
28.3
28.3
28.3
21 21 21 21
(3.6)
(3.6)
(3.6)
(3.6)
541
5 port solenoid valve Series 10-SYJ7000
2 position double ∗ [ ]: AC
G: Approx. 300
107.4[111.8] H: Approx. 600
63 (Lead wire length)
3
13
A B A B
Manual override
17 17
2-ø3.2 35 1/8 (A, B port)
(For manifold mounting)
One-touch fitting
(4.9)
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"
36
-+
28
25
16.1
21
31.5[38.5]
1.6
R1 P R2
18
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7223-씲L씲씲-01씲 10-SYJ7223-씲M씲씲-01씲 10-SYJ7223-씲D씲씲-01씲 10-SYJ7223-씲WO씲씲-01씲
(Lead wire length)
Approx. 300
65
31.5[38.5]
MAX.10
57.5
16.1 46.2
31.1 M8 x 1 36
Approx. 300 42.6[49.6] 18.5
(Lead wire length)
2-ø3.2
(For mounting) 2-ø3.2
127.2[131.6]
147.2
125.4
110.6
97.6
65.6
35
35
35
35
21
21
21 25
21 25
28 Pg7
25 25 28
Applicable cable O.D.
28 28
ø3.5 to ø7
542
5 port solenoid valve Series 10-SYJ7000
Air cylinder
G: Approx. 300
122[126.4] H: Approx. 600
(Lead wire length)
Rotary actuator
54.5[56.7]
45.3 32.3
3
13
A B A B
Manual override
17 17
2-ø3.2 1/8 (A, B port)
(For manifold mounting) 35
One-touch fitting
(4.9)
Air gripper
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"
36
- +
28
25
16.1
21
Directional control
31.5[38.5]
valve
1.6
R1 P R2
18
Flow control
equipment
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3 3
10-SYJ7 45 23-첸L첸첸-01첸 10-SYJ7 45 23-첸M첸첸-01첸 10-SYJ7 45 23-첸D첸첸-01첸 10-SYJ7 45 23-첸WO첸첸-01첸
(Lead wire length)
Approx. 300
65
31.5[38.5]
MAX.10
57.5
16.1
74.4
54.6[56.8]
73.5
63.5
56.1
49.6
Air preparation
33.6
equipment
141.8[146.2]
122.2[126.6]
35
35
35
35
161.8
160
140
46.6
62.6
28
28
28
Pg7 28
Clean gas filter
543
5 port solenoid valve Series 10-SYJ7000
2 position single ∗ [ ]: AC
22
12
34 8.5
2-ø4.3
Manual override B A (For mounting)
27
A
B
R2 P R1
- +
54
42.1
25.5
20
12
11.5
18 1/4 (R1, R2 port) 22 22
34 31.5
63
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7143-첸L첸첸- 0102 첸 10-SYJ7143-첸M첸첸- 0102 첸 10-SYJ7143-첸D첸첸- 01
02 첸 10-SYJ7143-첸WO첸첸- 01
02첸
(Lead wire length)
ø3.5 to ø7
91
MAX.10
57.5[64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
44.5
68.6[75.6] Approx. 300
20 20 20 20
Pg7
95.1[97.3]
104.2
85.3[87.5]
94.2
86.8
80.3
22
22
22
22
64.3
63
63
63
63
22
22
22
22
31.5
31.5
31.5
31.5
3.2
3.2
3.2
3.2
544
5 port solenoid valve Series 10-SYJ7000
2 position double ∗ [ ]: AC
Air cylinder
22
12
Rotary actuator
G: Approx. 300
H: Approx. 600 107.4[111.8]
(Lead wire length) 63
Air gripper
B A
27
A
B
Manual override R2 P R1
2-ø4.3 34 8.5
(For mounting)
Directional control
(Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port)
valve
57.5[64.5]
- +
42.1
25.5
20
12
11.5
22 22
Flow control
18 1/4 (R1, R2 port)
equipment
34 31.5
63
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7243-첸L첸첸- 0102첸 10-SYJ7243-첸M첸첸- 0102 첸 10-SYJ7243-첸D첸첸- 01
02 첸 10-SYJ7243-첸WO첸첸- 01
02첸
91
57.5[64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
68.6[75.6] Approx. 300 44.5
Air preparation
equipment
20 20 20 20
Pg7
127.2[131.6]
107.6[112]
22
22 22
22
22
147.2
145.4
110.6
125.4
97.6
65.6
63
63
63
63
22
22
22
31.5
31.5
31.5
31.5
Pressure switch
545
5 port solenoid valve Series 10-SYJ7000
3
Grommet (G), (H): 10-SYJ7 45 43-첸 GH첸첸- 01
02 첸
22
12
G: Approx. 300
H: Approx. 600 122[126.4]
(Lead wire length) 2-ø4.3 36[38.2]
(For mounting)
B A
27
A
B
R2 P R1
Manual override 34 8.5
63.8 13.8
- +
42.1
25.5
20
12
11.5
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3 3
10-SYJ7 45 43-첸L첸첸- 01
02 첸 10-SYJ7 45 43-첸M첸첸- 01
02 첸 10-SYJ7 45 43-첸D첸첸- 01
02첸 10-SYJ7 45 43-첸WO첸첸- 01
02첸
(Lead wire length)
91
57.5[64.5] 83.5
42.1 72.2
Pg7 62 M8 x 1
(Lead wire length) 57.1
68.6[75.6] Approx. 300 44.5
20 20 20 20
141.8[146.2]
87.6
122.2[126.6]
81.1
22
22
22 22
22
65.1
161.8
63
63
63
63
160
140
22
22
22
31.5
31.5
31.5
31.5
15.1
45.9[48.1]
31.1
12 12 12 12
55
MAX.10
546
Series 10-SYJ7000 Manifold specifications
Air cylinder
Manifold standard
Manifold specifications
Rotary actuator
Manifold type Single base / B mount
P (SUP) / R (EXH) Common SUP / Common EXH
Valve stations 2 to 15 stations 2 to 20 stations
A, B port porting Location Valve Base Base
specifications Direction Top Bottom Side
P, R port 1/8 1/4
Air gripper
1/8 C6 (One-touch
Port size A, B port C6 (One-touch fitting for ø6) 1/8 fitting for ø6)
C8 (One-touch fitting for ø8) C8 (One-touch
fitting for ø8)
Directional control
Flow characteristics
valve
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 1/8 2.2 0.35 0.57 2.3 0.26 0.55
Body
Flow control
equipment
ported
10-SS5YJ7-20 1/8 C6 1.4 0.32 0.37 2.0 0.25 0.49
for
10-SYJ7첸23 1/8 C8 1.7 0.38 0.45 2.1 0.25 0.51
1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
internal
pilot
10-SS5YJ7-21 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Base 10-SS5YJ7-40 1/4 1/8 2.1 0.28 0.51 2.5 0.23 0.59
control equipment
mounted 10-SS5YJ7-41 10-SYJ7첸43 1/4 1/8 2.0 0.30 0.50 2.2 0.30 0.55
Filter, Pressure
for internal 10-SS5YJ7-42-C6 1/4 C6 1.5 0.32 0.38 2.2 0.23 0.52
pilot 10-SS5YJ7-42-C8 1/4 C8 1.9 0.24 0.46 2.2 0.26 0.53
Note) Value at manifold base mounted, 2 position single operating
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the
Pressure switch
547
Manifold specifications 10-SYJ7000
Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
Body ported 10-SS5YJ7-21P-01 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
for internal 10-SS5YJ7-21P-C6 10-SYJ7첸23 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
pilot 10-SS5YJ7-21P-C8 1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Note) Value at manifold base mounted, 2 position single operating
548
Manifold specifications 10-SYJ7000
Manifold standard
Common SUP / Common EXH
Type 20 (5 port / Body ported) How to Order
A, B port 10-SS5YJ7-20- 05 -
Air cylinder
P,R port
thread type
Stations
Nil Rc
02 2 stations Applicable solenoid valve
00F G 01
P port 1/8 : : 10-SYJ7첸23-첸첸첸첸-C6
00N NPT C8
15 15 stations 00T NPTF
R port 1/8
Applicable blanking
Rotary actuator
Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
plate assembly
Type 21 (5 port / Body ported) How to Order SYJ7000-21-1A
A, B port 10-SS5YJ7-21- 05 - Applicable individual
P,R port EXH spacer assembly
Stations thread type
02 2 stations SYJ7000-17-1A
Nil Rc
P port 1/4 : :
00F G
20 20 stations
Air gripper
00N NPT
R port 1/4 00T NPTF
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Directional control
Stations A, B port size Thread type
02 2 stations 01 1/8 Nil Rc
valve
: : F G
R port 1/4 N NPT
20 20 stations
T NPTF
A, B port 1/8
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port. Applicable solenoid valve
Type 41 (5 port / Base mounted) How to Order 10-SYJ7첸43-첸첸첸첸
Flow control
10-SS5YJ7-41- 05 - 01
equipment
Applicable blanking
plate assembly
P port 1/4 Stations A, B port size Thread type SYJ7000-21-1A
02 2 stations 01 1/8 Nil Rc Applicable individual
: : F G EXH spacer assembly
N NPT SYJ7000-17-2A
20 20 stations
control equipment
Filter, Pressure
A, B port 1/8 T NPTF
R port 1/4 Applicable individual
Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. SUP spacer assembly
Type 42 (5 port / Base mounted) How to Order SYJ7000-16-2A
10-SS5YJ7- 42- 05 - C6
Stations A, B port size Thread type
02 2 stations C6 One-touch fitting for ø6 Nil Rc
A, B port
Applicable blanking
Stations P, R port plate assembly
thread type SYJ7000-21-3A
P port 1/4 03 3 stations
Nil Rc
: : Applicable connector
00F G
12 12 stations 00N NPT assembly
00T NPTF Refer to page 548.
Clean gas filter
R port 1/4
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
549
Manifold specifications 10-SYJ7000
<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base Mix installation of 10-SYJ700 and 10-SYJ7000 valves on the same manifold
Round head combination screw Round head combination screw 앬 Use of an adapter plate makes it possible to mount series 10-SYJ700 on the manifold bases of
M3 x 31 series 10-SYJ7000.
M3 x 31
앬 When mounting the 10-SYJ700 valve on the 10-SYJ7000 manifold, the 10-SYJ700 solenoid
Matt nickel plated Matt nickel plated must be positioned on the same side of a single solenoid of the 10-SYJ7000.
(With spring washer) (With spring washer) 앬 For base mounted style, the A port of the 3 port valve become the B port of manifold base.
Gasket Gasket
DXT199-21-10 DXT199-21-11
Round head
Applicable base Applicable base combination screw
· 10-SS5YJ7-20 · Sub-plate Round head
· 10-SS5YJ7-21 · 10-SS5YJ7-40 combination screw
· 10-SS5YJ7-41
· 10-SS5YJ7-42
Individual EXH spacer assembly
SYJ7000-17-1 A Thread type
SYJ7000-17-2 A Thread type
Round head Nil Rc Round head Nil Rc
F G F G
Gasket
combination screw combination screw
N NPT N NPT
T NPTF T NPTF
Round head
7
Round head combination screw
7
combination screw
B
B
O-ring
Manifold gasket
15
15
Individual R2 Individual R2
exhaust spacer exhaust spacer Applicable base Applicable base
· 10-SS5YJ7-20 · 10-SS5YJ7-40
R
R1 R1
R
· 10-SS5YJ7-21 · 10-SS5YJ7-41
· 10-SS5YJ7-42
Manifold Manifold
gasket gasket Blanking plate assembly
Applicable base Applicable base SYJ7000-21-1A
· 10-SS5YJ7-20 · 10-SS5YJ7-40
Round head combination screw
· 10-SS5YJ7-21 · 10-SS5YJ7-41
· 10-SS5YJ7-42
Individual SUP spacer assembly
SYJ7000-16-2 A Blanking plate Applicable base
· 10-SS5YJ7-20
Round head · 10-SS5YJ7-21
combination screw Gasket · 10-SS5YJ7-40
Thread type · 10-SS5YJ7-41
Nil Rc SYJ7000-21-3A · 10-SS5YJ7-42
F G
B
Blanking plate
Gasket
15
Individual
SUP spacer
P
Applicable base
Manifold Dust cap
· 10-SS5YJ7-40
gasket
· 10-SS5YJ7-41
Applicable base
· 10-SS5YJ7-42
Caution · 10-SS5YJ7-21P
Mounting screw tightening torque Use caution to the assembly orientation of solenoid valves, gasket, and optional parts.
M3: 0.8N·m
550
Manifold specifications 10-SYJ7000
Type 20: Top ported / 10-SS5YJ7-20- Stations -00 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
Air cylinder
L1 4-ø4.5
L2 6 (For mounting)
(DIN: 7.8)
(DIN: 21.6)
Rotary actuator
15.5
3
6.5
3.3
20.3
8
122[126.4]
107.4[111.8]
17 16.5
A
25
R
(DIN: 57.8)
(DIN: 58.6)
17 17
56.5
78.7[80.9]
57.3
50
79.5[81.7]
P
P
R
R
Air gripper
1/8 (P, R port)
Directional control
Built-in One-touch fitting
valve
(Station n) (Station 1)
-+ -+ -+ -+ -+
Flow control
equipment
ø8, ø5/16"
40.1
23.5
control equipment
(4.9) 60
Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
ø3.5 to ø7
55.5[62.5] 89
40.1 Pg7 81.5
(Lead wire length)
70.2
Approx. 300 66.6[73.6] M8 x 1 Air preparation
equipment
3.3
3.3
3.3
3.3
161.8
141.8[146.2]
122.2[126.6]
127.2[131.6]
107.6[112]
125.2
160
140
145.4
147.2
125.4
110.6
78.8[81]
88.6[90.8]
80.3
87.7
97.7
98.6
Pressure switch
0.8
0.8
42.5
0.8
0.8
60
0.8
0.8
551
Manifold specifications 10-SYJ7000
Type 21: Top ported / 10-SS5YJ7-21- Stations (-00 ) ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
L1
4-ø4.5
L2 10 (For mounting)
(DIN: 2.8)
(DIN: 16.6)
16.5
3 11.5
15.3
1.5
122[126.4]
107.4[111.8]
R
A
30
R
(DIN: 62.8)
(DIN: 63.6)
21
61.5
83.7[85.9]
62.3
84.5[86.7]
17
21
60
P
P
21
R
R
(Station n) (Station 1)
-+ -+ -+ -+ -+
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
43.1
26.5
(4.9) 63
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
Applicable cable O.D.
(Lead wire length)
Approx. 300
ø3.5 to ø7
MAX.10
58.5[65.5] 92
84.5
43.1 Pg7
73.2
(Lead wire length)
Approx. 300 69.6[76.6] M8 x 1
141.8[146.2]
122.2[126.6]
127.2[131.6]
107.6[112]
161.8
125.2
160
140
145.4
125.4
110.6
83.8[86]
147.2
93.6[95.8]
85.3
92.7
102.7
103.6
0.8
0.8
45.5
0.8
0.8
63
0.8
0.8
552
Manifold specifications 10-SYJ7000
Type 40: Bottom ported / 10-SS5YJ7-40- Stations -01 ∗ [ ]: AC
Air cylinder
4-ø4.5
L2 10 (For mounting)
16.5
(DIN: 16.6)
(DIN: 2.8)
11.5
15.3
0.5
1.5
Rotary actuator
122[126.4]
107.4[111.8]
R
A A A A A
(DIN: 63.6)
30
R
(DIN: 62.8)
21 21
83.7[85.9]
84.5[86.7]
62.3
61.5
21
60
P
P
B B B B B
R
R
Air gripper
Manual override (Pitch)
P = 19 23.5
(Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
58[65]
Directional control
42.6
26
valve
B B
19
40
Flow control
equipment
A A
(Pitch) 2
23.5
control equipment
P = 19
Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
Applicable cable O.D.
(Lead wire length)
Approx. 300
ø3.5 to ø7
MAX.10
91.5
122.2[126.6]
equipment
127.2[131.6]
107.6[112]
161.8
125.2
160
140
145.4
147.2
125.4
110.6
83.8[86]
93.6[95.8]
85.3
92.7
102.7
103.6
Pressure switch
0.8
0.8
45
0.8
0.8
62.5
0.8
0.8
553
Manifold specifications 10-SYJ7000
Type 41: Side ported / 10-SS5YJ7-41- Stations -01 ∗ [ ]: AC
Grommet (G)
31.5
20.5
85.2[87.4]
86[88.2]
107.4[111.8]
R
R
B B B B B
(DIN: 65.1)
(DIN: 64.3)
122[126.4]
19 19
63.8
19
63
60
P
P
31.5
22
A A A A A
R
R
(DIN: 15.1)
4-ø4.5
(Pitch)
29 P = 20 (For mounting)
Manual override
(Station 1) (Station n)
(Light/surge voltage suppressor)
-+ -+ -+
73[80]
57.6
A A
10.5
41
30.5
B B
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
106.5
99
73[80] 87.7
M8 x 1 77.5
0.8
0.8
57.6 60
0.8
0.8
0.8
0.8
95.1[97.3]
105.1
104.2
85.3[87.5]
127.2[131.6]
94.2
107.6[112]
86.8
141.8[146.2]
122.2[126.6]
145.4
147.2
125.4
110.6
161.8
125.2
160
140
84.1[91.1]
Approx. 300
(Lead wire length)
(Lead wire length)
MAX.10
ø3.5 to ø7
554
Manifold specifications 10-SYJ7000
Type 42: Side ported / 10-SS5YJ7-42- Stations - C6,N7
C8,N9 ∗ [ ]: AC
Grommet (G)
Air cylinder
L1
Manual override
14 L2
4-ø4.5
(For mounting) 32.5
19
Rotary actuator
85.9[88.1]
85.1[87.3]
107.4[111.8]
(DIN: 64.2)
R
B B B B B
R
(DIN: 65)
122[126.4]
18 18.5
62.9
63.7
59.9
21.9 19
P
P
31.4
A A A A A
R
R
(DIN: 15.2)
(4.9)
13.9
Air gripper
1/4 (P, R port)
(Pitch)
29 P = 19
Directional control
(Station 1) (Station n)
(Light/surge voltage suppressor)
valve
-+ -+ -+
74[81]
58.6
A A
42
29.5
8.5
B B
Flow control
equipment
8 (Pitch)
25 P = 19 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
control equipment
Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
107.5
74[81] 100 M8 x 1
88.7
78.5
58.6
0.8
61
0.8
0.8
0.8
95[97.2]
85.2[87.4]
104.1
105
127.2[131.6]
94.1
107.6[112]
141.8[146.2]
122.2[126.6]
86.7
145.4
147.2
125.4
110.6
161.8
125.2
160
140
Air preparation
equipment
85.1[92.1]
Approx. 300
Pressure switch
ø3.5 to ø7
555
Manifold specifications 10-SYJ7000
- +
4-ø4.5
(For mounting)
- + - +
16.5
1/8 (A, B port)
1.5
15.3
11.5
141.8[146.2]
127.2[131.6]
17 21.5
21 19.5
R
R
30
A
21 21
61.5
62.3
93.6[95.8]
94.4[96.6]
60
P
P
93.8
B
R
R
16
- + - + - + - + - +
(Station n) (Station 1)
(Light/surge voltage suppressor)
58.5[65.5]
32.3
26.5
28.5
8.8
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
(4.9) 63
556
Series 10-SYJ5000/7000
Made to order specifications
DIN terminal connector conforming to EN-175301-803C
(former DIN 43650C) standard
DIN terminal type conforming to DIN 43650C (DIN pitch 8mm) standard
Air cylinder
How to Order Valves
Light/surge voltage suppressor
Type of actuation
Nil Without light/surge voltage suppressor
1 2 position single solenoid
S With surge voltage suppresser
2 2 position double solenoid
Z With light/surge voltage suppresser Bracket
3 3 position closed center
Rotary actuator
∗ "YOZ" is not available. Nil Without bracket
4 3 position exhaust center ∗ For AC voltage valves, there is no "S" F With bracket
5 3 position pressure center option. It is already built-in to the
rectifier circuit. Note) Do not remove the factory
installed bracket from
models with the bracket
Rated voltage A, B port size option. Removal of the
DC specifications AC specifications (50/60Hz) M5 M5 x 0.8 bracket will cause air
5 24 VDC 1 100 VAC 01 1/8 (10- SYJ7000 only) leakage.
6 2
Air gripper
12 VDC 200 VAC C4 One-touch fitting for ø4
3 110 VAC [115 VAC] C6 One-touch fitting for ø6
4 220 VAC [230 VAC] N3 One-touch fitting for ø5/32"
N7 One-touch fitting for ø1/4
Directional control
Body ported 10 SYJ 5 1 23 5 Y M5
valve
Base mounted 10 SYJ 5 2 43 5 Y
Series Electrical entry Thread type
Flow control
equipment
5 10-SYJ5000 Nil Rc
Y: With connector F G
7 10-SYJ7000
N NPT
T NPTF
Port size
Nil Without sub-plate
control equipment
Filter, Pressure
10-SYJ5000
1 1/8
YO: Without connector 10-SYJ7000
2 1/4 10-SYJ7000
Manual override
Nil Non-locking push type
D Push-turn locking slotted type
DIN terminal 2. D type DIN connector with 9.4 mm pitch between terminals is not interchangeable.
YO Without connector 3. DIN connector except D type has the "N" indication in the end of voltage symbol. In
case of DIN connector without light, "N" is not indicated. Please refer to the name
plate to distinguish.
4. Dimensions are completely the same as D type connector.
5. When exchanging the pilot valve assembly only, "10-V115-첸D" is interchangeable
with "10-V115-첸Y". Do not replace 10-V114 (G, H, L, M, W) to 10-V115-첸D/첸Y
(DIN terminal), and vice versa.
557
Series 10-SYJ3000/5000/7000
Specific Product Precautions 1
Be sure to read before handling.
Warning Warning
When the manual override is operated, connected equipment will Solenoid valves with grommet and L/M type plug connector AC
be actuated. Confirm safety before operating. specificatinos have a built-in rectifier circuit in the pilot section to
operate the DC coil.
왎Non-locking push type (Standard) With 200/220 VAC specification pilot valves, this built-in rectifier
Press in the direction of the arrow. generates heat when energized. The surface may become hot
depending on the energized condition. Therefore, do not touch
the solenoid valves.
LOCK
Locked position
5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
LOCK
PUSH
5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
558
Series 10-SYJ3000/5000/7000
Specific Product Precautions 2
Be sure to read before handling.
Air cylinder
How to use plug connector Plug connector lead wire length
Caution Caution
Rotary actuator
1. Attaching and detaching connectors Standard length is 300 mm, but the following lengths are also
앬 To attach a connector, hold the lever and connector unit available.
between your fingers and insert straight onto the pins of the
solenoid valve so that the lever's pawl is pushed into the How to Order Connector Assembly
groove and locks.
For DC: SY100 30 4A
앬 To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
Air gripper
For 100 VAC: SY100 30 1A
connector straight out.
Cover
Groove For 200 VAC: SY100 30 2A
Pin
Cover
Groove For other voltages of AC: SY100 30 3A
Directional control
Lever
Pin
DC polarity display
Without lead wire: SY100 30 A Lead wire
valve
-+
Flow control
equipment
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the connector. 25 2500mm
ends of the core wires evenly into the sockets, and then crimp <Example> Lead wire length 2000 mm 30 3000mm
50 5000mm
with a crimping tool. (For DC) For AC
When this is done, take care that the coverings of the lead 10-SYJ3123-5LO-M3 10-SYJ3123-1LO-M3
wires do not enter the core wire crimping area. SY100-30-4A-20 SY100-30-1A-20
control equipment
Filter, Pressure
Use an exclusive crimping tool for crimping.
(For special crimping tools, please contact SMC.)
Core wire crimping area Crimping area
Socket Core wire
Lead wire 0.2 to 0.33mm2
Max. cover diameter: ø1.7 mm
connector. (When they are pushed in, their hooks open and
they are locked automatically.) Then confirm that they are
locked by pulling lightly on the lead wires.
앬 Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket's hook with a stick having a thin tip
Pressure switch
(approx. 1 mm).
If the socket will be used again, first spread the hook
outward.
Socket Connector
Clean gas filter
Lead wire
Hook
559
Series 10-SYJ3000/5000/7000
Specific Product Precautions 3
Be sure to read before handling.
Caution
(For DC)
Grommet, L/M plug connector type DIN terminal
왎Standard type (with polarity) With surge voltage suppresser (DS)
With surge voltage suppresser (첸S)
Varistor
Diode to prevent reverse current
Coil
Red (+)
Varistor
Red (+)
Coil
Coil
Black (–)
DIN terminal has no polarity.
왎Non-polar type
With surge voltage suppresser (첸R)
(–) (+) M8 connector type
Coil
Coil
Varistor
1 3
(+) (–)
3 (–)
· Connect the standard type in accordance with the +, – polarity
indication. Solenoid valve side
(The non-polar type can be used with the connections made Pin wiring diagram With light/surge voltage suppresser(첸Z)
either way.) Diode to prevent reverse current
Coil
make errors in the polarity.
· Be careful about the allowable voltage fluctuation since the 3 (–)
valves with a diode to prevent reverse current has about a 1V
voltage drop. (Refer to the solenoid specifications of each valve 왎Non-polar type
for details.) With surge voltage suppresser (첸R)
(Ground)
· When wiring is done at the factory, positive (+) is red and 1 (–) (+)
negative (–) is black. 4
Coil
왎With power saving circuit Electric circuit (with power saving circuit)
Varistor
3 (+) (–)
Power consumption is de- Red (+)
Diode
Timer circuit
LED
the wattage required to hold With light/surge voltage suppresser (첸U)
the valve in an energized 1 (–) (+)
1 2
state. (Effective energizing Black (–) Solenoid valve side
Coil
560
Series 10-SYJ3000/5000/7000
Specific Product Precautions 4
Be sure to read before handling.
Air cylinder
Surge voltage suppressor How to use DIN Terminal
<For AC> Ground nut
(There is no "S" type because the generation of surge voltage is Tightening torque
Rotary actuator
prevented by a rectifier.) 1.65 to 2.5 N·m
Holding screw
Tightening torque
Grommet, L/M plug connector 0.4 N·m
Washer
With indicator light (첸Z) Grommet
(~)
(Rubber) Housing
Varistor
Coil
(Rating symbol)
Refer to table of
(~) DIN connector part no. (Light mounting
location )
Air gripper
Terminal screw Terminal block
DIN terminal (3 locations) Notch
With indicator light (DZ) Tightening torque
(~)
0.2 to 2.5 N·m
Varistor
Coil
Directional control
(~) DIN connector part no.
NL : Neon ball
valve
Note) Surge voltage suppressor of varistor has residual voltage
corresponding to the protective element and rated voltage. Caution
Therefore, protect the controller side from the surge.
The residual voltage of the diode is approximately 1 V. Without light SY100-61-1
With light
Flow control
Rated voltage Voltage symbol Part no.
equipment
How to use DIN Terminal 24 VDC 24V SY100-61-3-05
12 VDC 12V SY100-61-3-06
control equipment
Filter, Pressure
solenoid valve terminal block.
2. After removing the holding screw, insert a flat head Circuit diagram with light
screwdriver, etc. into the notch on the bottom of the terminal AC circuit DC circuit
block and pry it open, separating the terminal block and the
housing.
3. Loosen the terminal screws (slotted screws) on the terminal
block, insert the cores of the lead wires into the terminals
Also, be sure to tighten the ground nut and holding screw within
their specified torque ranges.
Caution
Changing the entry direction
After separating the terminal block and housing, the cord entry
Pressure switch
side.
Compatible cable
Cord O.D.: ø3.5 to ø7
(Reference) 0.5 mm2, 2 core or 3 core, equivalent to JIS C 3306
561
Series 10-SYJ3000/5000/7000
Specific Product Precautions 5
Be sure to read before handling.
Caution Caution
Connector assembly with dustproof protective cover 1. M8 connector types have an IP65 (enclosure) rating, offering
· Effective to prevent short circuit failure due to the entry of foreign protection from dust and water. However please note that
matter into the connector these products are not intended for use in water.
· Chloroprene rubber for electrical use, which provides outstand- Select a SMC connector cable (V100-49-1-첸) or a FA sensor
ing weather resistance and electrical insulation, is used for the type connector, with M8 threaded 3 pin specifications
cover material. However, do not allow contact with cutting oil, conforming to Nippon Electric Control Equipment Association
etc. Standard, NECA4202 (IEC60947-5-2). Make sure the
· Simple and unencumbered appearance by adopting round- connector O.D. is 10.5 mm or less when used with the Series
shaped cord. 10-SY3000 manifold. If more than 10.5mm, it cannot be
mounted due to the size.
How to Order 2. Do not use a tool to mount the connector, as this may cause
damage. Only tighten by hand. (0.4 to 0.6N)
SY100-68-A 3. Do not apply excessive power greater than 30N to the connec-
Lead wire length tor cable, otherwise IP65 cannot be satisfied.
Nil 300mm
6 600mm
Caution
10 1000mm Failure to meet IP65 performance may result if using alternative
15 1500mm connectors than shown above, or when insufficiently tightened.
20 2000mm
25 2500mm · Connector cable mounting
30 3000mm
50 5000mm
Triangle mark
Arrow mark
Connector assembly with cover: Dimensions
(40) Gray
(10)
(ø4.1)
(6.9)
MConnector cable
· Connector cable for M8 can be ordered as follows:
562
Series 10-SYJ3000/5000/7000
Specific Product Precautions 6
Be sure to read before handling.
Air cylinder
M8 connector Flat ribbon cable manifold
2. To order connector cable only Internal wiring of manifold
Rotary actuator
(Ground) Connector dimensions
4 Brown: 1 Blue: 3 Station 12 Station 4 Station 3 Station 2 Station 1
Coil
ø9
3 1
Black: 4 Side A Side B Side A Side B Side A Side B Side A Side B Side A Side BTriangle mark
33.9 Coil Coil Coil Coil Coil Coil Coil Coil Coil Coil Indicated position
L 35 10 25 23
7 5 3 1 Note)
Connector
Air gripper
26 24
8 6 4 2
Cable length (L) Part no.
300mm V100-49-1-1
) ( ) Side A Coil
) ( ) Side B Coil
( ) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Common
) ( ) Common
500mm V100-49-1-2
1000mm V100-49-1-3
2000mm V100-49-1-4 + +
Directional control
+ + + + + + + + + +
5000mm V100-49-1-7
-
-
{((
-
-
-
-
-
-
-
-
-
-
{ ((
{(
{ ((
{ ((
{ ((
Connected
valve
on the
22 33.9 board Station 12 Station 4 Station 3 Station 2 Station 1
1
Triangle mark 2
(Max. 12 stations)
3
24
25
Reference figure 26
Note)
14
Flow control
equipment
Terminal no. is not indicated on the connector. The terminal no.
indicated in the connection schematic of connector, as shown in
the reference, means a correlation of 1, 2, 3···26 from the triangle
mark side on the flat ribbon cable of connector.
Flat ribbon cable manifold
· For more than 10 stations, both poles of the common should be
control equipment
Caution wired.
Filter, Pressure
· For single solenoid, connect to the solenoid B side.
Type 21P Type 32P · The maximum number of stations that can be accommodated is
12. Please contact SMC for more stations.
· Only non-polar valves are available for the DC flat ribbon cable
manifold, therefore negative COM or positive COM wiring of the
manifold is possible. The valve dose not switch with negative
Bracket
• In the manifold valves, the wiring to the individual valves is
provided on a printed circuit board, and the connection to the
external wires is consolidated through the use of a flat cable.
Caution
For 10-SYJ3000 (Single) or 10-SYJ7000 with bracket, do not use
•A single MIL flat cable connects the entire manifold to your
Air preparation
it without bracket.
equipment
Caution
Pressure switch
10-SYJ7000 M3 0.8N·m
563
Series 10-SYJ3000/5000/7000
Specific Product Precautions 7
Be sure to read before handling.
Caution
Pilot valves in this series are improved to provide excellent
energy saving results. However, following this improvement,
these new valves are no longer compatible with the conventional
pilot valve used at the interface. Please consult with SMC when
you need to exchange these pilot valves, in the case of manual
override (marked in orange) of the adapter plate.
New type
Manual override
(Blue)
-+
B
A
Interface
Pilot valve
(10-V111) Adapter plate
Conventional type
Manual override
(Orange)
-+
B
A
Interface
Pilot valve
(10-SY114) Adapter plate
564
Series 10-SYJ3000/5000/7000 Rubber seal
4/5 port solenoid valve
Variations
Option
Sonic conductance Type of Manual
Series Voltage Electrical entry
C[dm3/(s·bar)] actuation Light/Surge override
voltage suppresser
10-SYJ5000
0.47 왎 With light/surge
L plug connector voltage suppressor
4/2→5/3
(A/B→EA/EB) }
P.515
+
–
10-SYJ7000 For AC
2.4 2 position M plug connector
4/2→5/3
(A/B→EA/EB) } · Single
· Double
왎AC 100V / Hz
50
60
AC 110V 50
/ Hz60
AC 200V 50
/ Hz60 +–
P.537 AC 220V 50
/ Hz60
왎 Non-locking
push type
10-SYJ3000
3 position
0.46
· Closed center
4/2→5/3
(A/B→EA/EB) } · Exhaust center
· Pressure center
왎 Push-turn
Base mounted type
10-SYJ7000 M8 connector
2.9
4/2→5/3
(A/B→EA/EB) }
P.537
Note) All standard AC voltage models have built-in surge voltage suppresser.
492
4/5 port solenoid valve Series 10-SYJ3000/5000/7000
Manifold variations
A, B port size Manifold option
One-touch fitting
Air cylinder
A, B port Flat ribbon cable manifold
Valve series Individual Individual
location M3 M5 1/8 Applicable tubing O.D. SUP spacer EXH spacer
assembly assembly
ø4 ø6 ø8 N3 N7 N9
10-SYJ3000 앬 — — — — — — — — — — 앬
Body ported
Rotary actuator
10-SYJ5000 Top — 앬 — 앬 앬 — 앬 앬 — 앬 앬 앬
10-SYJ7000 — — 앬 — 앬 앬 — 앬 앬 — 앬 앬
Side 앬 앬 — 앬 — — 앬 — — 앬
Air gripper
10-SYJ3000 — —
Bottom — — — — — — — — — —
Base mounted
Side — 앬 — 앬 앬 — 앬 앬 — 앬
Directional control
10-SYJ5000 앬 앬
앬
valve
Bottom — — — — — — — — —
Side — — 앬 — 앬 앬 — 앬 앬 —
10-SYJ7000 앬 앬
Bottom — — 앬 — — — — — —
Flow control
—
equipment
Body ported Type 21P
A, B port
P port
control equipment
Filter, Pressure
Individual SUP
R port spacer assembly
Base mounted
P port
P
Type 32P
R port
A, B port
P port
Air preparation
equipment
R1
R port
· For detailed specifications about 10-
A, B port SYJ3000, refer to page 507. For 10-
P port SYJ5000, refer to page 529, and for
10-SYJ7000, refer to page 550.
Clean gas filter
493
Series 10-SYJ3000 Rubber seal
4/5 port solenoid valve
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure range (MPa) 2 position double 0.1 to 0.7
3 position 0.2 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (with no freezing. Refer to page 714.)
Response time ms 2 position single, double 15 or less
(0.5MPa) Note 1) 3 position 30 or less
2 position single, double 10
Max. operating frequency (Hz)
3 position 3
Body ported Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
2 Note 2)
Shock/Vibration resistance m/s 150/30
Enclosure Dustproof (∗ M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature : 20°C, at rated voltage and
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000Hz. Test
was performed to axis and right angle directions of the main valve when pilot signal is ON and
Base mounted OFF. (Value in the initial state)
Solenoid specifications
JIS Symbol
5 port 4 port (For manifold
use only) Electrical entry Grommet (G)/(H), L plug connector (L),
2 position single 2 position single M plug connector (M), M8 connector (W)
(B) (A) (B)(A)
2 4 2 4 DC 24, 12, 6, 5, 3
Coil rated voltage V
AC50/60Hz 100, 110, 200, 220
3 1 5
(R) (P) (R)
1 3 Allowable voltage fluctuation ±10% of rated voltage ∗
(P) (R)
2 position double 2 position double Standard 0.35 (With indicator light: 0.4)
(B) (A) (B) (A) Power consumption (W) DC
2 4 2 4 With power saving circuit 0.1 (With indicator light only)
100 VAC 0.78 (With indicator light: 0.81)
3 1 5 110 VAC 0.86 (With indicator light: 0.89)
(R) (P) (R) 1 3
(P) (R)
Apparent power (VA) ∗ [115 VAC] [0.94(With indicator light: 0.97)]
3 position closed center 3 position closed center AC
(B) (A) (B) (A) 200 VAC 1.18 (With indicator light: 1.22)
2 4 2 4
220 VAC 1.30 (With indicator light: 1.34)
3 1 5 [230 VAC] [1.42 (With indicator light: 1.46)]
(R) (P) (R) 1 3
(P) (R) Surge voltage suppressor Diode (Non-polar type: Varistor)
3 position exhaust center 3 position exhaust center Indicator light LED
(B)(A) (B) (A)
2 4 2 4
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is -15% to +5% of rated voltage.
3 1 5
(R) (P) (R) 1 3 ∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please
(P) (R) observe the following range because they have voltage drop due to internal circuit.
3 position pressure center 3 position pressure center
(B) (A) (B) (A) S and Z types 24 VDC: -7% to +10% 12 VDC: -4% to +10%
2 4 2 4 T type 24 VDC: -8% to +10% 12 VDC: -6% to +10%
3 1 5
Bracket mounting
(R) (P)(R) 1 3
(P) (R) (1) Insert the lower hook of the mounting (2) Press the valve and mounting bracket
bracket into the groove on the bottom of together until the upper hook of the bracket
the valve as shown. snaps into place in the groove on top of the
Made to valve.
Order Made to order specifications
(Refer to page 557 for details.)
494
4/5 port solenoid valve Series 10-SYJ3000
Flow characteristics / Weight
Port size Weight (g) Note 3, 4) Flow characteristics Note 2)
Effective
Valve model Type of actuation 1, 5, 3 4, 2 L/M plug M8 area mm 2 1→4/2(P→A/B) 4/2→5/3(A/B→EA/EB)
Grommet
Air cylinder
(P, EA, EB) (A, B) connector Connector C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv
10-SYJ3143 2 Single 62(36) 63(37) 67(41) —
0.46 0.36 0.12 0.46 0.35 0.12
5 port base 10-SYJ3243 position Double 79(53) 81(55) 89(63)
mounted 10-SYJ3343 Closed center M5 x 0.8 M5 x 0.8 — 0.47 0.33 0.12 0.47 0.31 0.12
(With sub-plate) 10-SYJ3443 3 Exhaust center 82(56) 84(58) 92(66) — 0.36 0.39 0.10 0.59[0.40] 0.43[0.33] 0.16[0.11]
position
10-SYJ3543 Pressure center — 0.58[0.32] 0.42[0.33] 0.16[0.080] 0.46 0.32 0.11
10-SYJ3123 2 Single 36 37 41
Rotary actuator
10-SYJ3223 position Double 53 55 63
5 port
10-SYJ3323 Closed center M3 x 0.5 M3 x 0.5 0.9
body ported 3
10-SYJ3423
position
Exhaust center 56 58 66
10-SYJ3523 Pressure center
10-SYJ3133 2 Single 36 37 41 —
4 port base 10-SYJ3233 position Double 53 55 63
mounted
10-SYJ3333 Closed center 1/8 M5 x 0.8 —
(For manifold 3
base only)Note 1) 10-SYJ3433 position Exhaust center 56 58 66 —
Air gripper
10-SYJ3533 Pressure center —
Note 1) Dedicated for manifold base, refer to page 11 for details.
Note 2) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 3) ( ): Without sub-plate
Note 4) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the
weight of the double solenoid and 3 position types.
Directional control
valve
Flow control
equipment
control equipment
Filter, Pressure
Fittings & Tubing
Air preparation
equipment
Pressure switch
Clean gas filter
495
4/5 port solenoid valve Series SYJ3000
How to Order
Light/surge voltage suppressor Bracket
Type of actuation Nil Without light/surge voltage suppressor Nil: Without bracket F: With bracket
1 2 position single solenoid S With surge voltage suppressor
2 2 position double solenoid Z With light/surge voltage suppressor
3 3 position closed center R With surge voltage suppressor (Non-polar type)
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
5 3 position pressure center
∗ For AC voltage valves, there is no "S" option. It is -+
5 port Rated voltage Note) The double solenoid mounting bracket is supplied
unattached.
DC AC (50/60Hz) To order the double solenoid bracket for use with a
5 24 VDC 1 100 VAC single solenoid valve, order the single solenoid
valve without a bracket and double solenoid
6 12 VDC 2 200 VAC
bracket separately by specifying the part number
V 6 VDC 3 110 VAC [115 VAC] of the bracket VJ3000-13-1besides the part
S 5 VDC 4 220 VAC [230 VAC] number of the solenoid valve.
∗ For type "W첸", DC voltage [Example] 10-SYJ3123-5M-M3
R 3 VDC
(Type 20 manifold) is only available. VJ3000-13-1
Electrical entry
24, 12, 6, 5, 3 VDC 24, 12 VDC
100, 110, 200, 220 VAC 6, 5, 3 VDC
Grommet L plug connector M plug connector M8 connector E: Push-turn locking lever type
G: Lead wire L: With lead M: With lead wire MN: Without WO: Without connector
length wire (length (length 300 mm) lead wire cable
300 mm 300 mm)
+– +–
–+
–+
H: Lead wire LN: Without LO: Without MO: Without W첸: With connector
length lead wire connector connector cable Note 1)
600 mm
–+
–+
How to Order Pilot Valve Assembly How to Order Connector Assembly for L/M Plug Connector
Air cylinder
10 V111 5 G For DC : SY100-30-4A-
Clean series
Light/Surge voltage suppressor
For 100 VAC : SY100-30-1A-
Nil Without light/surge voltage suppressor
Coil specifications S With surge voltage suppresser For 200 VAC : SY100-30-2A-
Rotary actuator
Nil Standard Z With light/surge voltage suppresser
R
T
With power saving circuit
<24, 12 VDC only> U
With surge voltage suppressor (Non-polar type)
With light/surge voltage suppressor (Non-polar type)
For other voltages of AC : SY100-30-3A-
∗ Power saving circuit ∗ For AC voltage valves, there is Without lead wire
is not available in
the case of "W첸"
no "S" option. It is already built-
in to the rectifier circuit.
(With connector and 2 of sockets only) : SY100-30-A
type. ∗ For "R" and "U", DC voltage is
only available. Lead wire length
∗ Power saving circuit is only available Nil 300mm
Air gripper
in the "Z" type. 6 600mm
10 1000mm
Rated voltage Electrical entry 15 1500mm
5 24 VDC G Grommet (Lead wire length 300 mm) 20 2000mm
6 12 VDC H Grommet (Lead wire length 600 mm) 25 2500mm
V 6 VDC L With lead wire 30 3000mm
S 5 VDC L plug 50 5000mm
LN connector Without lead wire
Directional control
R 3 VDC
1 100 VAC50/60Hz LO Without connector
2 200 VAC50/60Hz M With lead wire
valve
M plug
3
110 VAC50/60Hz
[115 VAC50/60Hz]
MN connector Without lead wire How to Order M8 Connector Cable
MO Without connector
220 VAC50/60Hz WO M8 Without connector cable
4
[230 VAC50/60Hz] W첸 Connector With connector cable Note 1) V100-49-1-
∗ For type "W첸", DC ∗ For connector cable of M8 connector,
voltage is only avail- refer to page 562.
Cable length
Flow control
equipment
able. Note 1) Be sure to enter a symbol of the
cable length in 첸 with reference 1 300mm
to page 562. 2 500mm
3 1000mm
4 2000mm
7 5000mm
control equipment
Filter, Pressure
Fittings & Tubing
Air preparation
equipment
Pressure switch
Clean gas filter
497
4/5 port solenoid valve Series 10-SYJ3000
2 position single ∗[ ]: AC
G: Approx. 300
54.4[56.6] H: Approx. 600
(Lead wire length) 28.4
32.2 2-ø3.5 22 3.2
(For mounting)
13.2 7.1
16.4
10
- +
8.2
4
A B
11.5 19.3
7 Manual override
34.7[41.7]
M3 x 0.5 2-ø1.8
(A, B port) (For manifold mounting) (Light/surge voltage suppressor)
28[35]
-+
22.1
13.5
12.6
54.4[56.6]
15
2
R P R (Bracket) 15
11
10
22.1
7 7
15 M3 x 0.5
(P, R port)
28[35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
64.3[66.5]
54.5[56.7]
63.4
56
49.5
(2)
(2)
(2)
498
4/5 port solenoid valve Series 10-SYJ3000
2 position double ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ3223-첸 H 첸첸-M3 (-F)
Air cylinder
G: Approx. 300
78.8[83.2] H: Approx. 600
34.4 (Lead wire length)
7.1
1.8
Rotary actuator
4
8.2 A B
Air gripper
Equivalent to 2-ø3.2 Bracket (Light/surge voltage suppressor)
(For mounting) (18.5)
28[35]
(18.5)
22.1
-+
13.5
12.6
15
Directional control
valve
(11.5)
10 0.5
R P R
14
Flow control
equipment
M3 x 0.5
(P, R port)
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 connector (WO):
10-SYJ3223-첸L첸첸-M3 (-F) 10-SYJ3223-첸M첸첸-M3 (-F) 10-SYJ3223-첸WO첸첸-M3 (-F)
(Lead wire length)
Approx. 300
28[35]
79[83.4]
96.8
69
82
Pressure switch
15
22.1 15
15
22.1
22.1
Clean gas filter
499
4/5 port solenoid valve Series 10-SYJ3000
3
Grommet (G), (H): 10-SYJ3 45 23-첸GH첸첸-M3 (-F)
G: Approx. 300
91.7[96.1] H: Approx. 600
40.2[42.4] (Lead wire length)
29.3 18
1.8 5.3
4
8.2
A B
28[35]
(18.5)
22.1
-+
13.5
12.6
15
(11.5)
10 0.5
R P R
14
M3 x 0.5
(P, R port)
28[35]
12.6
M8 x 1 32.5
15
Approx. 300 39.1[46.1]
(Lead wire length)
50.1[52.3]
40.3[42.5]
49.2
41.8
35.3
91.9[96.3]
109.7
46.6
53.1
15
22.1 15
15
22.1
22.1
500
4/5 port solenoid valve Series 10-SYJ3000
2 position single ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ3143-첸 H 첸첸-M5
Air cylinder
M5 x 0.8 10
(A, B port)
5
10
Rotary actuator
2-ø3.2 32.2
(For mounting)
22 4
2.5
Manual override
B A
11
A
B
Air gripper
G: Approx. 300 1
H: Approx. 600 54.4[56.6]
(Light/surge voltage suppressor) (Lead wire length)
Directional control
41.5[48.5]
-+
35.6
valve
28.5
26.1
R2 P R1
13
10 10 10 M5 x 0.8
17.5 (Mounting hole)
14
28
Flow control
equipment
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 Connector (WO):
10-SYJ3143-첸L첸첸-M5 10-SYJ3143-첸M첸첸-M5 10-SYJ3143-첸WO첸첸-M5
(Lead wire length)
41.5[48.5]
26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
Air preparation
equipment
64.3[66.5]
54.5[56.7]
63.4
56
49.5
R2
R2
R2
10 10
10 10
10 10
28
28
28
P
P
14
14
14
R1
R1
R1
Pressure switch
5 5 5
28.5 28.5 28.5
35.6 35.6 35.6
Clean gas filter
501
4/5 port solenoid valve Series 10-SYJ3000
2 position double ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ3243-첸 H 첸첸-M5
M5 x 0.8 10
(A, B port)
5
10
2-ø3.2
(For mounting) 22
2.5
Manual override
11
G: Approx. 300 34.4
H: Approx. 600 78.8[83.2]
(Light/surge voltage suppressor) (Lead wire length)
41.5[48.5]
35.6
26.1
13
10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)
28
41.5[48.5]
26.1
46 M8 x 1
28.5
52.6[59.6] Approx. 300
(Lead wire length)
98.6[103]
79[83.4]
10 10
10 10
10 10
96.8
28
28
69
28
82
14
14
14
5 5 5
502
4/5 port solenoid valve Series 10-SYJ3000
Air cylinder
M5 x 0.8
10 (A, B port)
5
10
Rotary actuator
2-ø3.2 32 15.3
(For mounting)
22 3
2.5
Manual override
B A
11
Air gripper
A
B
37.5[39.7]
G: Approx. 300
H: Approx. 600 91.7[96.1]
(Lead wire length)
(Light/surge voltage suppressor)
Directional control
41.5[48.5]
-+
valve
35.6
26.1
R2 P R1
13
10 10 10 M5 x 0.8
17.5 14 (P, R1, R2 port)
Flow control
equipment
28
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): M8 Connector (WO):
3 3 3
10-SYJ3 45 43-첸L첸첸-M5 10-SYJ3 45 43-첸M첸첸-M5 10-SYJ3 45 43-첸WO첸첸-M5첸
(Lead wire length)
Approx. 300
41.5[48.5]
R2
R2
91.9[96.3]
10 10
10 10
10 10
28
28
28
109.7
P
P
14
14
14
R1
R1
R1
5 5 5
37.6[39.8]
47.4[49.6]
32.6
Pressure switch
39.1
46.5
503
Series 10-SYJ3000 Manifold specifications
Manifold standard
Manifold specifications
Model Type 20 Type 31/S31 Type 32/S32 Type 41/S41 Type 46/S46
Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R) Effective
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C (mm2)
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
Body ported for
10-SS5YJ3-20 10-SYJ3첸23 M5 x 0.8 M3 x 0.5 — — — — — — 0.9
internal pilot
10-SS5YJ3-31-S31 10-SYJ3첸33 M5 x 0.8 M3 x 0.5 — — — — — — 0.9
10-SS5YJ3-32-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 —
10-SS5YJ3-32-C4 C4 0.25 0.18 0.059 0.30 0.27 0.075 —
10-SYJ3첸33 1/8
10-SS5YJ3-S32-M5 M5 x 0.8 0.25 0.26 0.060 0.29 0.15 0.062 —
10-SS5YJ3-S32-C4 C4 0.24 0.21 0.057 0.27 0.18 0.062 —
Base mounted for 10-SS5YJ3-41-M5 M5 x 0.8 0.32 0.25 0.081 0.33 0.19 0.079 —
internal pilot 10-SS5YJ3-41-C4 C4 0.32 0.28 0.079 0.35 0.24 0.084 —
10-SYJ3첸43 1/8
10-SS5YJ3-S41-M5 M5 x 0.8 0.33 0.29 0.082 0.34 0.17 0.081 —
10-SS5YJ3-S41-C4 C4 0.32 0.27 0.079 0.34 0.24 0.084 —
10-SS5YJ3-46-M5 M5 x 0.8 0.20 0.25 0.048 0.10 0.12 0.024 —
10-SS5YJ3-46-C4 1/8 C4 0.21 0.27 0.050 0.21 0.13 0.047 —
10-SYJ3첸43
10-SS5YJ3-S46-M5 M5 x 0.8 M5 x 0.8 0.20 0.25 0.048 0.19 0.16 0.024 —
10-SS5YJ3-S46-C4 C4 0.22 0.34 0.057 0.10 0.090 0.024 —
Note) Value at manifold base mounted, 2 position single operating
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
504
Manifold specifications 10-SYJ3000
Air cylinder
Model Type 21P Type 32P
use of the flat ribbon Manifold Single base / B mount
cable connector. P(SUP) / R(EXH) Common SUP / Common EXH
Valve stations 4 to 12 stations
• Clean appearance A, B port piping Location Valve Base
specifications Direction Top Side
Rotary actuator
In the case of a flat ribbon cable type, each valve
is wired on the print board of manifold base to P, R port 1/8
allow the external wiring to be piped all together Port size
A, B port M3 x 0.5 M5 x 0.8 C4 (One-touch fitting for ø4)
with 26 pins MIL connector.
Applicable flat ribbon
cable connector Socket: 26 pins MIL type with strain relief (conforming to MIL-C-83503)
Internal wiring In common between +COM and –COM (Z type: +COM only).
Rated voltage 12, 24 VDC, 100, 110 VAC
Note) The withstand voltage specification for the wiring unit section conforms to JIS C0704, Grade 1 or
Air gripper
its equivalent.
Flow characteristics
Directional control
Type 21P Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R) Effective
valve
Manifold area
1(P), 5/3(R) 2(B), 4(A) C C (mm2)
port b Cv b Cv
port [dm /(s·bar)]
3 [dm /(s·bar)]
3
Body ported
for internal pilot
10-SS5YJ3-21P 10-SYJ3첸23 1/8 M3 x 0.5 — — — — — — 0.9
Base mounted 10-SS5YJ3-32P-M5 M5 x 0.8 0.25 0.19 0.060 0.32 0.25 0.077 —
for internal pilot 10-SS5YJ3-32P-C4
10-SYJ3첸33 1/8
C4 0.25 0.18 0.059 0.3 0.27 0.075 —
Flow control
equipment
Note) Value at manifold base mounted, 2 position single operating
control equipment
∗ 10-SYJ3133-5LOU ····3 sets (Valve) ∗ SY3000-37-28A ··3 sets (Connector assembly)
Filter, Pressure
∗ 10-SYJ3233-5LOU ····3 sets (Valve) ∗ SY3000-37-29A ··3 sets (Connector assembly)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
2
Air preparation
505
Manifold specifications 10-SYJ3000
Common SUP / Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
P port : :
R port
M5 x 0.8 M5 x 0.8 20 20 stations
Common SUP / Individual EXH Note) For more than 10 stations, supply air to both sides of P port.
B
A, B port M5 M5 x 0.8
A, B port P port N NPT
M5 x 0.8, C4
M5 x 0.8, C4 1/8 C4 One-touch fitting for ø4 T NPTF
P port
N3 One-touch fitting for ø5/32"
1/8
506
Manifold specifications 10-SYJ3000
Common SUP / Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Air cylinder
Applicable solenoid valve
Type 21P How to Order
Refer to page 505.
A, B port
M3 x 0.5 10--SS5YJ3--21P-- 07 -- Applicable connector
P, R port assembly
Clean series thread type Refer to page 505.
Manifold stations
Rotary actuator
Nil Rc Applicable blanking
04 4 stations
00F G plate assembly
: :
P port
R port
00N NPT SYJ3000-21-3A
12 12 stations
1/8 1/8 00T NPTF (With dust cap)
Air gripper
M5 x 0.8, C4 assembly
Clean series P, R port
thread type Refer to page 505.
Manifold stations A, B port size Nil Rc Applicable blanking
04 4 stations M5 M5 x 0.8
plate assembly
F G
SYJ3000-21-4A
P port : : C4 One-touch fitting for ø4 N NPT
R port (With dust cap)
Directional control
1/8 1/8 12 12 stations N3 One-touch fitting for ø5/32" T NPTF
valve
Mixed installation of the 10-SYJ300 and the 10-SY3000 valves on the same manifold
Series 10-SYJ300 valves can be mounted on the manifolds for 10-SY3000.
Flow control
equipment
q 10-SS5YJ3-20, 10-SS5YJ3-21P (10-SYJ300 3 port valve)
The 3 port valve can be used by simply sealing off the unused "R"
port with rubber plug, SYJ3000-33-1.
Applicable solenoid valves: Type 10-SYJ312M
Type 10-SYJ322M
(10-SYJ300 3 port valve)
control equipment
Filter, Pressure
w 10-SS5YJ3-31/-S31, 10-SS5YJ3-32/-S32,
10-SS5YJ3-46/-S46, 10-SS5YJ3-32P
The 3 port valve can be used without modification. Plug (SYJ3000-33-1) Plug (SYJ3000-33-1)
The A port of the valve will flow out of the B Seal the unused "R"
Seal the unused "R"
port of the manifold. port on the end cover port on the end cover
Applicable solenoid valve: Type 10-SYJ314M side of the manifold. side of the manifold.
Type 10-SYJ324M
Caution
Mounting screw tightening torque
M1.7: 0.12N·m Type 10-SS5YJ3-20 Type 10-SS5YJ3-41
507
Manifold specifications 10-SYJ3000
<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base
5 port body ported 4 port base mounted 5 port base mounted
(Type 10-SYJ3첸23) (Type 10-SYJ3첸33) (Type 10-SYJ3첸43)
Round head combination screw
SY100-33-3
(M1.7 x 17, matt nickel plated)
Applicable manifold base Applicable manifold base Applicable manifold base
Type 10-SS5YJ3-31 Type 10-SS5YJ3-41
Type 10-SS5YJ3-20
Type 10-SS5YJ3-S31 Type 10-SS5YJ3-S41 Manifold
Type 10-SS5YJ3-21P Manifold
Type 10-SS5YJ3-32 base Type 10-SS5YJ3-46 base
Manifold base Type 10-SS5YJ3-S32 Type 10-SS5YJ3-S46
Type 10-SS5YJ3-32P
A mark A mark Protrusion for
positioning Manifold gasket
A
Manifold gasket A
Manifold gasket
SYJ3000-14-7 SYJ3000-14-6 SYJ3000-14-2
Note) Please insert the protrusion for positioning of
the manifold gasket into the hole of the valve
body completely.
Combination of blanking plate assembly and manifold base Difference between types 10-SYJ3첸33 and 10-SYJ3첸43
Blanking plate assembly Blanking plate assembly Type 10-3첸33 (4 port) Type 10-3첸43 (5 port)
SYJ3000-21-1A SYJ3000-21-2A
Round head
combination screw
Blanking plate Steel ball is driven in
Blanking plate
A mark A mark
Blanking plate
Blanking plate A mark
A mark
Manifold gasket
Manifold gasket
Caution
Mounting screw tightening torque
M1.7: 0.12N·m
Applicable base Applicable base Use caution to the assembly orientation for
Type 10-SS5YJ3-32P manifold base Type 10-SS5YJ3-21P manifold base solenoid valves, gasket and option parts.
508
Manifold specifications 10-SYJ3000
Type 20 manifold: Top ported / 10-SS5YJ3-20- Stations ∗ [ ]: AC
Approx. 300
Air cylinder
(Pitch)
P = 10.5 12.5
Manual
Rotary actuator
override
4 5
3.7
15.8
1.5
91.7[96.1]
78.8[83.2]
7 10
R
R
A A A A A
14
19.5
11 10
30.7
31.5
29
52.9[55.1]
53.7[55.9]
B B B B B
R
R
Air gripper
2-ø3.5 M5 x 0.8
(For mounting) (P, R port)
M3 x 0.5
(A, B port)
L2 3.5
Directional control
L1
valve
(Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
Flow control
42[49]
equipment
26.6
13.5
control equipment
Filter, Pressure
L plug connector (L) M plug connector (M) M8 connector (WO)
(Lead wire length)
Approx. 300
42[49]
26.6
1.5
1.5
Air preparation
111.5[115.9]
91.9[96.3]
equipment
109.7
98.6[103]
94.9
79[83.4]
96.8
82
53[55.2]
62.8[65]
54.5
61.9
Pressure switch
0.8
0.8
0.8
0.8
29
46.5
509
Manifold specifications 10-SYJ3000
Type 31 manifold: Side ported / 10-SS5YJ3-31- Stations -M3 ∗ [ ]: AC
2-ø3.5
(For mounting) Manual
override
M5 x 0.8
5.2
7.5
17.3
(P, R port)
52.2[54.4]
51.4[53.6]
3
91.7[96.1]
78.8[83.2]
78.8[83.2]
13.5
A A A A A
B B B B B
R
R
R
29.2
91.7[96.1]
R
30
29.2
25
12
25
51.4[53.6]
30
52.2[54.4]
3 13.5
B B B B B
P
P
P
P
A A A A A
17.3
7.5
5.2
-+ -+ -+ -+ -+ -+ -+
28.1
A A B B
15
15
12
12
B B A A
3
3
1 (Pitch) (Pitch) 1
13.5 P = 10.5 M3 x 0.5 M3 x 0.5 P = 10.5 14.5
(A, B port) (A, B port)
0.8
0.8
0.8
61.3[63.5]
51.5[53.7]
60.4
53
98.6[103]
111.5[115.9]
79[83.4]
91.9[96.3]
96.8
82
109.7
94.9
28
Approx. 300
43.4[47.3]
510
Manifold specifications 10-SYJ3000
C4
Type 32 manifold: Side ported / 10-SS5YJ3-32- Stations -M5, N3 첸 ∗ [ ]: AC
Air cylinder
2-ø4.5
(For mounting)
36.5
1/8
17
10
53.4[55.6]
54.2[56.4]
(P, R port)
78.8[83.2]
91.7[96.1]
31.5
3.2 31.2
R
12.5
(4.4)
B B B B B
32
17
1 16
P
P
A A A A A
7.5
Rotary actuator
15.3
(Station 1) (Station n)
L1
(Pitch) 4.5 L2
15.5 P = 10.5 (Light/surge voltage
15.5
suppressor)
(Station 1) (Station n) -+ -+
20
15
5
48.5[55.5]
B B
-+ -+
Air gripper
A A 16 P = 10.5 (A, B port)
20
15
B B
Applicable tubing O.D.:
5
Directional control
M8 x 1 53
0.8
0.8
35.5
0.8
valve
0.8
63.3[65.5]
53.5[55.7]
111.5[115.9]
62.4
98.6[103]
79[83.4]
91.9[96.3]
55
96.8
109.7
82
94.9
1
Flow control
equipment
(Lead wire length)
Approx. 300
control equipment
Filter, Pressure
Pilot valve of single solenoid valve is C4
Type S32 manifold: Side ported located on the same side of A and B ports. / 10-SS5YJ3-S32- Stations -M5, N3 첸
L1 C4 첸(With built-in One-touch fitting)
M5 L2 4 N3
override 10
15.5
34.2 0.2
91.7[96.1]
78.8[83.2]
36.5
17
56.4[58.6]
57.2[59.4]
31.5
R
A A A A A
35
B B B B B
P
P
12.5
(4.4)
2-ø4.5
Air preparation
-+ -+ -+ -+ -+
B B
20
15
5
A A
B B
20
1
5
15
M5 x 0.8 (Pitch)
Pressure switch
A A
L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5
10-SS5YJ3-32,S32- Stations -C4
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 42.5 53 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5
L2 33.5 44 54.5 65 75.5 86 96.5 107 117.5 128 138.5 149 159.5 170 180.5 191 201.5 212 222.5
511
Manifold specifications 10-SYJ3000
Type 41 manifold: Side ported / 10-SS5YJ3-41- Stations -M5, C4
N3 첸 ∗ [ ]: AC
36.4
10 10
61.7[63.9]
60.9[63.1]
(P port)
21.4
78.8[83.2]
91.7[96.1]
R
39.5 B B B B B
38.7
36.5
18
4.3
21.5
R
(4.4)
P
A A A A A
3
11.5
7.8
20
15
48.5[55.5]
B B
5
-+ -+
2 One-touch fitting
33.1
(Pitch)
A A
17 P = 10.5 (A, B port)
20
15
5
35.5
0.8
0.8
0.8
70.8[73]
61[63.2]
69.9
111.5[115.9]
98.6[103]
62.5
79[83.4]
91.9[96.3]
96.8
109.7
82
94.9
(Lead wire length)
33 14.3
78.8[83.2]
1/8
10
(P port)
54.4[56.6]
A A A A A
R
55.2[57.4]
33.5
36.5
P
B B B B B
R
36.4
21.4
2-ø4.5
(4.4)
L2 4 (For mounting)
L1
(Station n) (Station 1) (Light/surge voltage suppressor) (Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
-+ -+ -+ -+ -+
B B
20
15
B B
20
A A
15
A A
5
2 (Pitch) 2
M5 x 0.8 (Pitch) One-touch fitting
P = 10.5 15
P = 10.5 15 (A, B port)
(A, B port)
Applicable tubing O.D.:
ø4 and ø5/32"
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
512
Manifold specifications 10-SYJ3000
Type 46 manifold: Side ported / 10-SS5YJ3-46- Stations -M5, C4
N3 첸 ∗ [ ]: AC
Approx. 300
(Lead wire length)
Grommet (G) C4 첸 (With built-in One-touch fitting)
M5 (Pitch) N3
Air cylinder
14.5 P = 10.5
1/8
10 (P port)
Manual
override
1/8
34.9
10
59.9[62.1]
60.7[62.9] (P port)
18.9
78.8[83.2]
91.7[96.1]
B B B B B
38.5
37.7
35
3.3
P
(4.4)
Rotary actuator
19
A A A A A
10
8.8
2-ø4.5
4 L2 (For mounting) (Station 1) (Station n)
L1 (Light/surge voltage suppressor)
(Station 1) (Station n)
-+ -+
(Light/surge voltage suppressor)
Air gripper
48.5[55.5]
A A
20
15
-+ -+
B B
5
33.1
Directional control
L plug connector (L) M plug connector (M) M8 connector (WO)
valve
M8 x 1 53
0.8
35.5
0.8
0.8
0.8
69.8[72]
60[62.2]
68.9
111.5[115.9]
98.6[103]
61.5
79[83.4]
91.9[96.3]
Flow control
equipment
96.8
109.7
82
94.9
(Lead wire length)
Approx. 300
control equipment
Filter, Pressure
(Lead wire length)
33
48.5[55.5]
∗ Refer to page 563 for dimensions with
connector cable.
1/8
78.8[83.2]
Air preparation
10
equipment
(P port)
A A A A A
53.9[56.1]
54.7[56.9]
25
35
P
B B B B B
34.9
18.9
2-ø4.5
(4.4)
L2 4 (For mounting)
L1
Pressure switch
-+ -+ -+ -+ -+
(Light/surge voltage suppressor) -+ -+ -+ -+ -+
B B
20
B B
20
15
15
A A
5
A A
5
(A, B port)
(A, B port) Applicable tubing O.D.:
ø4 and ø5/32"
Stations n 2 Stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Stations
L1 39.5 50 60.5 71 81.5 92 102.5 113 123.5 134 144.5 155 165.5 176 186.5 197 207.5 218 228.5
L2 31.5 42 52.5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
513
Manifold specifications 10-SYJ3000
L1
L2 4
Manual override
-+ -+ -+
M3 x 0.5 -+
(A, B port) 10
2 2
5.2
111.5[115.9]
30 17.3
7.5
7 8.5
16 3
98.6[103]
A
P
P
29.2
31.5
61.3[63.5]
62.1[64.3]
17
45.5
B
65.3
R
2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+
Triangle mark
(Pitch) 1/8
P=12.5 18.5 (P, R port)
(Station n) (Station 1)
(Light/surge voltage suppressor)
48.5[55.5]
25.6
5.8
20
28.5
B B
One-touch fitting (A, B port) P = 12.5 19.5
15
A
Applicable tubing O.D.: ø4 and ø5/32" 1
A
5
B B
15
20
A A
L1
L2 4
Manual override
-+ -+ -+
-+
10 10
3.2
32 15.3
7.5
(4.4)
111.5[115.9]
12.4
1
98.6[103]
16
A A A A A A
P
P
31.2
31.5
17
63.3[65.5]
64.1[66.3]
36.4
B B B B B B
R
R
65.3
17
50.4
70.2
2-ø4.5
(For mounting) -+ -+ -+ -+ -+ -+
Triangle mark
(Pitch) 1/8
P = 12.5 18.5 (P, R port) 1/8
(Station n) (Station 1) (P, R port)
(Light/surge voltage suppressor)
Applicable connector: 26 pins MIL type
With strain relief
48.5[55.5]
(Conforming to MIL-C-83503)
5.8
25.6
20
514
Series 10-SYJ5000 Rubber seal
5 port solenoid valve
Air cylinder
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure
2 position double 0.1 to 0.7
range MPa
3 position 0.15 to 0.7
Ambient and fluid temperature -10 to 50°C (with no freezing. Refer to page 714.)
Rotary actuator
Response time ms Note 1) 2 position single, double 25 or less
(0.5 MPa) 3 position 40 or less
Max. operating 2 position single, double 5
frequency (Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the main and pilot valve
Lubrication Not required
Body ported
Mounting orientation Unrestricted
Air gripper
Impact/Vibration resistance m/s2 Note 2) 150/30
Enclosure Dustproof (∗ DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve
and armature in both energized and de-energized states every once for each condition. (Value in the initial state)
Directional control
Vibration resistance: No malfunction occurred in one sweep between 45 and 2000Hz. Test was performed in the axial direction and at the right angles
to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state)
valve
Solenoid specifications
Grommet(G), (H) , L plug connector (L),
M plug connector (M), DIN terminal (D),
Electrical entry M8 connector (W)
Base mounted
G, H, L, M, W D
JIS Symbol DC 24, 12, 6, 5, 3 24, 12
Rated coil voltage V
Flow control
equipment
AC 50/60Hz 100, 110, 200, 220
Body ported Base mounted Allowable voltage fluctuation ±10% of rated voltage ∗
(With sub-plate)
Standard 0.35 {With indicator light: 0.4 (DIN terminal with indicator light: 0.45)}
2 position single 2 position single Power consumption (W) DC
With power saving circuit 0.1 (With indicator light only)
(A) (B) (B)(A) 100V 0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)
4 2 2 4 110V 0.86 (With indicator light: 0.89) 0.86 (With indicator light: 0.97)
[115V] [0.94 (With indicator light: 0.97)] [0.94 (With indicator light: 1.07)]
Apparent power (VA) ∗ AC
control equipment
5 1 3 200V 1.18 (With indicator light: 1.22) 1.15 (With indicator light: 1.30)
Filter, Pressure
3 1
(R1) (P) (R2) (R)(P) 220V 1.30 (With indicator light: 1.34) 1.27 (With indicator light: 1.46)
2 position double 2 position double [230V] [1.42 (With indicator light: 1.46)] [1.39 (With indicator light: 1.60)]
(A) (B) (B)(A) Surge voltage suppressor Diode (DIN terminal, varistor for non-polar types)
4 2 2 4 Indicator light LED (Neon light for DIN terminal AC)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
5 1 3 3 1 ∗ For 115 and 230 VAC, the allowable voltage fluctuation is -15% to +5% of rated voltage.
(R1) (P) (R2) (R)(P) ∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please
observe the following range because they have voltage drop due to internal circuit.
5 1 3
Built-in speed controller
(R1) (P) (R2) 3 1
(R)(P)
10-SYJ5첸53 Throttle valve characteristics ( AB →R)
앬 Built-in exhaust flow controls enable simple cylinder speed
3 position exhaust center 3 position exhaust center
adjustments.
Effective area (mm2)
(A) (B) (B)(A) 앬 When mounted on the manifold, the common exhaust discharges
Air preparation
4 2 2 4
the pilot and main valve exhaust through a common EXH port to 2
equipment
5 1 3
(Fully closed) (Fully open)
(R1) (P) (R2) 3 1
(R) (P)
How to order valve with Note) 앬 When using 10-SYJ5첸53 model, the speed controller
built-in speed controller must be opened more than 1 complete rotation from
fully closed in order to function properly.
Made to
10--SYJ5 53 -- -- 앬 Adjust the speed controller with a torque of 0.3 N·m
Order Made to order specifications or less.
Type of Port size
(Refer to page 557 for details.) actuation Plate fixing screw
Manual override
Clean gas filter
Clean series
Rated voltage Light/Surge voltage
Electrical entry suppressor
Note) Do not loosen plate fixing screw.
515
5 port solenoid valve Series 10-SYJ5000
Flow characteristics / Weight
Port size Flow characteristics Note 1) Weight (g) Note 2, 3)
Valve model Type of actuation 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
Grommet L/M plug DIN terminal M8 connector
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv connector
Single 46 47 68 51
2 position 0.47 0.41 0.13 0.47 0.41 0.13 74
Double 64 66 108
10-SYJ5첸23-첸-M5 Closed center M5 x 0.8 M5 x 0.8 0.49 0.44 0.13 0.44 0.40 0.12
3 position Exhaust center 0.46 0.37 0.12 0.47[0.39] 0.43[0.35] 0.13[0.10] 75 77 119 85
Pressure center 0.49[0.39] 0.51[0.38] 0.14[0.10] 0.45 0.42 0.12
Single 53 54 75 58
Body ported
516
5 port solenoid valve Series 10-SYJ5000
How to Order
Light/Surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Air cylinder
Type of actuation Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
S With surge voltage suppresser S With surge voltage suppressor (Non-polar type)
1 2 position single solenoid
Z With light/surge voltage suppresser Z With light/surge voltage suppressor (Non-polar type)
2 2 position double solenoid
R With surge voltage suppresser (Non-polar type) ∗ "DOZ" is not available.
3 3 position closed center
U With light/surge voltage suppresser (Non-polar type) ∗ For AC voltage valves, there is no "S" option.
4 3 position exhaust center It is already built-in to the rectifier circuit.
5 3 position pressure center ∗ For AC voltage valves, there is no "S" option.
It is already built-in to the rectifier circuit. Bracket
Rotary actuator
∗ For "R" and "U", DC voltage is only available.
∗ Power saving circuit is only available in the "Z" type. Nil: Without bracket
F: With bracket
Rated voltage
DC specifications AC specifications (50/60Hz)
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC[115 VAC] M5 M5 x 0.8
S 5 VDC 4 220 VAC[230 VAC] C4 One-touch fitting for ø4
Air gripper
R 3 VDC ∗ For type "W첸", DC C6 One-touch fitting for ø6
∗ DC specifications voltage is only N3 One-touch fitting for ø5/32"
of type "D" and "DO" available. N7 One-touch fitting for ø1/4"
is only available with Note) The mounting bracket is
(For manifold type 20) 12 and 24 VDC. supplied unattached.
Directional control
Body ported 10 SYJ5 1 23 5 L M5
valve
Base mounted 10 SYJ5 2 43 5 L
Thread type
Clean series
Flow control
equipment
Nil Rc
Coil specifications Manual override F G
Nil Standard N NPT
Nil: Non-locking push type
With power saving circuit T NPTF
T
<For 24 and 12 VDC only>
∗ Power saving circuit is not
Port size
control equipment
Sub-plate, 40, 41, 42,
available in the case of "D",
Filter, Pressure
43 manifold
"DO" or "W첸" type. Nil: Without sub-plate
D: Push-turn locking
slotted type
G: Lead wire length L: With lead wire M: With lead wire MN: Without lead wire D: With connector WO: Without connector lever type
equipment
–+
–+
Pressure switch
H: Lead wire length LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector W첸: With connector
600 mm cable Note 1)
–+
Clean gas filter
–+
517
5 port solenoid valve Series 10-SYJ5000
How to Order Pilot Valve Assembly How to Order Connector Assembly for L/M Plug Connector
518
5 port solenoid valve Series 10-SYJ5000
2 position single ∗ [ ]: AC
G
Grommet (G), (H):10- SYJ5123-첸 첸첸-M5 H With bracket
G
10-SYJ5123-첸 H 첸첸-M5-F
Air cylinder
37
G: Approx. 300
63.1[65.3] H: Approx. 600 2-ø3.5 30 3.5
(Lead wire length) (For mounting)
41
19.5
18
25
-+
Rotary actuator
11
19.7
5
A B
35.1[42.1]
M5 x 0.8 10 Manual override
(A, B port) 19 2-ø2.6
(For manifold mounting)
63.1[65.3]
2-M3 x 0.5 (Light/surge voltage suppressor)
Air gripper
(Mounting screw)
-+
18
23
20
(Bracket)
2.3
28.1[35.1]
2.5
12.7
10.6 11 2-ø2.6 Built-in One-touch Fitting:
Directional control
3.5 4 (For mounting) G C4,N3
10-SYJ5123-첸 H 첸첸- C6,N7 (-F)
valve
19.5
3.5
A B
R1 P
16
15
Flow control
M5 x 0.8 21 (3.2)
equipment
(A, B port)
(P, R1, R2 port) Applicable tubing O.D.: ø4 and ø5/32"
: ø6, ø1/4"
32.3
control equipment
(2.3)
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5123-첸L첸첸-M5(-F) 10-SYJ5123-첸M첸첸-M5(-F) 10-SYJ5123-첸D첸첸-M5(-F) 10-SYJ5123-첸WO첸첸-M5(-F)
ø3.5 to ø7
MAX.10
28.1[35.1] 60.9
53.4
12.7
42.1
M8 x 1 32.6
Air preparation
15.1
equipment
63.2[65.4]
82.1
83
72.1
58.2
64.7
3 3 3 3
42.2
Pressure switch
19.5
19.5
19.5
11
11
11
19.5
11
(2.3)
(2.3)
20 2-ø2.6
(2.3)
519
5 port solenoid valve Series 10-SYJ5000
2 position double ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ5223-첸 H 첸첸-M5 Built-in One-touch fitting
10-SYJ5223-첸 GH 첸첸-C4,N3
C6,N7
G: Approx. 300
87.2[91.6] H: Approx. 600
43 (Lead wire length)
3.5
11
5
A B A B
One-touch fitting
(3.2)
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D.: ø4 and ø5/32"
: ø6, ø1/4"
32.3
-+
23
20
12.7
28.1[35.1]
3
11 2-ø2.6
(For mounting)
R1 P
15
R2
M5 x 0.8 21
(P, R1, R2 port)
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5223-첸L첸첸-M5 10-SYJ5223-첸M첸첸-M5 10-SYJ5223-첸D첸첸-M5 10-SYJ5223-첸WO첸첸-M5
(Lead wire length)
ø3.5 to ø7
MAX.10
28.1[35.1] 60.9
12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2[46.2]
(Lead wire length)
Pg7
20 20 20 20
107[111.4]
3 3 3
87.4[91.8]
3
105.2
125.2
90.4
77.4
45.4
127
11
11
11
11
23
2-ø2.6 2-ø2.6 2-ø2.6
(For mounting) (For mounting) (For mounting)
23
23
23
27
2-ø2.6
(For mounting)
520
5 port solenoid valve Series 10-SYJ5000
3 position closed center / exhaust center / pressure center ∗ [ ]: AC
3
Grommet (G), (H): 10-SYJ5 45 23-첸GH 첸첸-M5 Built-in One-touch fitting:
3
10-SYJ5 45 23-첸GH 첸첸- C4,N3
Air cylinder
C6,N7
G: Approx. 300
103.2[107.6] H: Approx. 600
44.2[46.4] (Lead wire length)
36.9 22.1 44.2[46.4]
3.5
11
5
Rotary actuator
A B A B
One-touch fitting
(3.2)
(Light/surge voltage suppressor) (A, B port)
Applicable tubing O.D: ø4 and
Air gripper
ø5/32"
32.3
: ø6, ø1/4"
-+
23
20
12.7
28.1[35.1]
3
11 2-ø2.6
(For mounting)
Directional control
valve
R1 P
15
R2
M5 x 0.8 21
(P, R1, R2 port)
Flow control
equipment
control equipment
Filter, Pressure
L plug connector
3
(L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3
10-SYJ5 5 23-첸L첸첸-M5
4 10-SYJ5 45 23-첸M첸첸-M5 10-SYJ5 45 23-첸D첸첸-M5 10-SYJ5 45 23-첸WO첸첸-M5
(Lead wire length)
28.1[35.1] 60.9
12.7 53.4
42.1 M8 x 1 32.6
15.1
Approx. 300 39.2[46.2]
(Lead wire length)
Air preparation
Pg7
equipment
54.1[56.3]
44.3[46.5]
64.1
63.2
53.2
45.8
39.3
20 20 20 20
23.3
3 3 3 3
103.4[107.8]
123[127.4]
11
11
11
141.2
121.2
143
11
38.1
23 2-ø2.6 23 2-ø2.6 23 23
Pressure switch
54.1
60.6
27
Clean gas filter
521
5 port solenoid valve Series 10-SYJ5000
2 position single ∗ [ ]: AC
G
Grommet (G), (H): 10-SYJ5143-첸 H 첸첸-01첸 Built-in speed controller:
G
10-SYJ5153-첸 H 첸첸-01첸
MAX.13.5
1/8 19.4 10.3
17 11.5
(A, B port)
8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24
B
R P
-+
45
8.5
34.7
21.5
15 17 17
24 1/8 45.5
32 (P, R port)
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5143-첸L첸첸-01첸 10-SYJ5143-첸M첸첸-01첸 10-SYJ5143-첸D첸첸-01첸 10-SYJ5143-첸WO첸첸-01첸
(Lead wire length)
ø3.5 to ø7
82.9
MAX.10
50.1[57.1] 75.4
34.7 64.1
49 54.6 M8 x 1
37.1
61.2[68.2] Approx. 300
(Lead wire length) Pg7
6 6 6 6
73.5[75.7]
63.7[65.9]
83.5
82.6
65.2
72.6
58.7
45.5
45.5
45.5
45.5
17 17
17 17
17 17
17 17
42.7
0.5
0.5
0.5
6 6 6 6
0.5
522
5 port solenoid valve Series 10-SYJ5000
2 position double ∗ [ ]: AC
Air cylinder
1/8 17 11.5
(A, B port)
MAX.13.5
8.5
19.4 10.3
Rotary actuator
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24
B
Air gripper
R P
41.5 1.5
G: Approx. 300 23.6[25.8]
H: Approx. 600 87.2[91.6]
(Lead wire length)
Directional control
(Light/surge voltage suppressor)
valve
50.1[57.1]
-+
45
34.7
8.5
21.5
Flow control
15 17 17
equipment
24 1/8 45.5
32 (P, R port)
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ5243-첸L첸첸-01첸 10-SYJ5243-첸M첸첸-01첸 10-SYJ5243-첸D첸첸-01첸 10-SYJ5243-첸WO첸첸-01첸
ø3.5 to ø7
Approx. 300
82.9
MAX.10
50.1[57.1] 75.4
34.7 64.1
49 54.6
M8 x 1
61.2[68.2] Approx. 300 37.1
Air preparation
equipment
65.2
87.4[91.8]
58.7
45.5
45.5
45.5
45.5
125.2
105.2
17 17
17 17
17 17
17 17
42.7
127
2.7
Pressure switch
18.7
6 6 6 6
25.2
32.6
42.6
8.5
21.5
23.7[25.9]
523
5 port solenoid valve Series 10-SYJ5000
1/8 17 11.5
MAX.13.5
(A, B port)
19.4 10.3
8.5
2-ø4.3
(For mounting)
37.5 4
Manual override
B A
24
B
R P
42.1 16.9
39[41.2]
G: Approx. 300
H: Approx. 600 103.2[107.6]
(Lead wire length)
-+
45
34.7
21.5
15 17 17
8.5
1/8
24 45.5
(P, R port)
32
L plug connector
3
(L): M plug connector
3
(M): DIN Terminal
3
(D): M8 connector
3
(WO):
10-SYJ5 45 43-첸L첸첸-01첸 10-SYJ5 45 43-첸M첸첸-01첸 10-SYJ5 45 43-첸D첸첸-01첸 10-SYJ5 45 43-첸WO첸첸-01첸
Applicable cable O.D.
(Lead wire length)
ø3.5 to ø7
Approx. 300
82.9
MAX.10
50.1[57.1] 75.4
64.1
34.7
49 54.6 M8 x 1
61.2[68.2] Approx. 300 37.1
(Lead wire length) Pg7
6 6 6 6
65.8
59.3
103.4[107.8]
123[127.4]
45.5
45.5
45.5
45.5
43.3
17 17
17 17
17 17
17 17
141.2
121.2
143
18.1
6 6 6 6
48.9[51.1]
34.1
40.6
58
524
Series10-SYJ5000 Manifold specifications
Air cylinder
Manifold standard
Manifold specifications
Rotary actuator
Manifold type Single base / B mount
Air gripper
P, R port 1/8 1/4 1/8
Port size M5 x 0.8 1/8, C6
C4 (One-touch
A, B port C4 (One-touch fitting for ø4) M5 x 0.8 (One-touch
C6 (One-touch fitting for ø6) fitting for ø6) fitting for ø4)
Directional control
Flow characteristics
valve
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3(A/B→R)
Manifold model
1(P), 5/3(R) 2(B), 4(A) C C
port port [dm3/(s·bar)] b Cv [dm3/(s·bar)] b Cv
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
10- SS5YJ5-20 10-SYJ5첸23 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
for internal pilot
Flow control
equipment
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
10-SS5YJ5-40 1/8 M5 x 0.8 0.55 0.35 0.15 0.64 0.26 0.16
10-SS5YJ5-41 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
Base mounted
10-SS5YJ5-42-01 10-SYJ5첸43 1/4 1/8 0.74 0.22 0.18 0.82 0.31 0.21
for internal pilot
10-SS5YJ5-42-C6 1/4 C6 0.71 0.24 0.17 0.8 0.29 0.20
10-SS5YJ5-43 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
control equipment
Note) Value at manifold base mounted, 2 position single operating
Filter, Pressure
How to Order Manifold (Example)
525
Manifold specifications 10-SYJ5000
Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 M5 x 0.8 0.46 0.39 0.12 0.75 0.32 0.19
Body ported
10-SS5YJ5-20P 10-SYJ5첸23 1/8 C4 0.62 0.33 0.16 0.83 0.27 0.20
for internal pilot
1/8 C6 0.79 0.36 0.21 0.91 0.36 0.24
Base mounted 10-SS5YJ5-41P 1/8 M5 x 0.8 0.59 0.35 0.16 0.68 0.23 0.17
10-SYJ5첸43
for internal pilot 10-SS5YJ5-43P 1/8 C4 0.55 0.29 0.14 0.74 0.32 0.19
Note) Value at manifold base mounted, 2 position single operating
526
Manifold specifications 10-SYJ5000
Common SUP / Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Air cylinder
M5 x 0.8 Applicable blanking
Clean series plate assembly
-+ P, R port
-+
P port Number of stations thread type SYJ5000-21-4A
1/8 02 2 stations Applicable individual
R
Nil Rc
P
R
: : 00F G EXH spacer assembly
R port 20 20 stations 00N NPT SYJ5000-17-1A
Rotary actuator
1/8 00T NPTF
Air gripper
02 2 stations Nil Rc Applicable individual
: : F G EXH spacer assembly
R port
20 20 stations N NPT SYJ5000-17-1A
A, B port 1/8
T NPTF
M5 x 0.8 A, B port size
M5 M5 x 0.8
Directional control
valve
Type 41 (5 port / base mounted) How to Order
10 SS5YJ5 41 05 M5
Clean series
Number of stations
Flow control
equipment
-+
-+ 02 2 stations P, R port
R port thread type
: :
R
1/8 Nil Rc
P
A, B port 20 20 stations
F G
M5 x 0.8 P port
A, B port size N NPT
1/8
M5 M5 x 0.8 T NPTF
control equipment
Filter, Pressure
Type 42 (5 port / base mounted) How to Order
Applicable solenoid valve
10 SS5YJ5 42 05 C6 10-SYJ5첸43-첸첸첸첸
Clean series 10-SYJ5첸53-첸첸첸첸
Number of stations Applicable blanking
-+ 02 2 stations plate assembly
-+
1/4
A Thread type
A, B port size EXH spacer assembly
A, B port B Nil Rc
P port
01 1/8
SYJ5000-17-1A
1/8, C6 F G
1/4
C6 One-touch fitting for ø6
Applicable individual
N NPT
SUP spacer assembly
N7 One-touch fitting for ø1/4" T NPTF
SYJ5000-16-2A
Air preparation
10 SS5YJ5 43 05 C4
Clean series
Manifold stations
-+
-+ 02 2 stations
Pressure switch
R port : : P, R port
R
thread type
P
1/8
A, B port A 20 20 stations
B Nil Rc
C4 P port
A, B port size F G
1/8
C4 One-touch fitting for ø4 N NPT
N3 One-touch fitting for ø5/32" T NPTF
Clean gas filter
527
Manifold specifications 10-SYJ5000
Flat ribbon cable manifold
Common SUP / Common EXH Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Type 20P (5 port / body ported) How to Order Applicable solenoid valve
Refer to page 526.
A, B port
10 SS5YJ5 20P-- 05
Applicable blanking
P port Clean series P, R port plate assembly
1/8 thread type SYJ5000-21-3A
Number of stations
Nil Rc
03 3 stations
00F G Applicable connector
: : assembly
R port 00N NPT
1/8 12 12 stations 00T NPTF Refer to page 526.
<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base
Round head combination screw Round head combination screw
M2.5 x 25 M2.5 x 25
Matt nickel plated Matt nickel plated
(With spring washer) (With spring washer)
Blanking plate
Blanking plate
Gasket Gasket
Caution
Applicable base Mounting screw tightening torque
· 10-SS5YJ5-20
M2.5: 0.45N·m
· 10-SS5YJ5-40 Dust cap Applicable base
· 10-SS5YJ5-41 · 10-SS5YJ5-20P Use caution to the assembly
· 10-SS5YJ5-42 orientation for solenoid valve,
· 10-SS5YJ5-41P
· 10-SS5YJ5-43
gasket, and optional parts.
· 10-SS5YJ5-43P
528
Manifold specifications 10-SYJ5000
<Manifold option>
Mix installation of the 10-SYJ500 and the 10-SYJ5000 valves on the same manifold
앬 Use of an adapter plate makes it possible to mount Series 10-SYJ500 on the manifold bases of series 10-SYJ5000.
Air cylinder
앬 When mounting the 10-SYJ500 valve on the 10-SYJ5000 manifold, the 10-SYJ500 solenoid must be positioned on the same side of the manifold as a single solenoid of 10-SYJ5000.
앬 For base mounted style, the A port of the 3 port valve flows out the B port of manifold base.
Rotary actuator
Round head combination screw
Gasket
Air gripper
Round head combination screw
Round head combination screw
Adaptor plate
7
Adaptor plate
7
Adaptor gasket
Directional control
valve
Adaptor gasket Applicable base
· 10-SS5YJ5-40
Applicable base · 10-SS5YJ5-41
· 10-SS5YJ5-20 · 10-SS5YJ5-42
· 10-SS5YJ5-43
Flow control
equipment
SYJ5000-17-1A
SYJ5000-16-2 A
Round head combination screw Round head combination screw
Thread type
Nil Rc
control equipment
Filter, Pressure
F G
N NPT
T NPTF
B
A
A
Manifold gasket
Manifold gasket
15
529
Manifold specifications 10-SYJ5000
Type 20: Top ported / 10-SS5YJ5-20- Station -00첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
(DIN: 14.6)
(Pitch)
16.515.2
(DIN: 46.2)
(DIN: 46.8)
23.5
87.2[91.6]
16.516.5
R
R
A
A
45.6
67.1[69.3]
67.7[69.9]
45
49
P
P
B
B
R
4-ø4.5 1/8
(For mounting) (P, R port)
M5 x 0.8
Manual override L2 9 (A, B port)
L1
Built-in One-touch fitting
(Station n) (Station 1)
-+ -+ -+ -+ -+
33.2
20
(3.2) 52.8
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
Approx. 300
MAX.10
87.4[91.8]
141.2
121.2
106.4
143
125.2
105.2
67.2[69.4]
90.4
127
77[79.2]
68.7
76.1
86.1
87
0.6
0.6
35.6
0.6
0.6
33.2
53.1
0.6
0.6
48.6[55.6] 62.6
73.9
81.4
530
Manifold specifications 10-SYJ5000
Type 40: Bottom ported / 10-SS5YJ5-40- Stations -M5첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
Air cylinder
L1
L2 9
4-ø4.5
(For mounting)
Rotary actuator
13
8.5
(DIN: 23.3) (DIN: 38.1)
16.5
43.6[45.8] 23.5
22.1 36.9
21.5 21.5
R
A A A A A
87.2[91.6]
33
47
P
P
44.2[46.4]
B B B B B
R
2.5
Air gripper
1/8
(Pitch) (P, R port)
P = 16 21 Manual override
(Station n) (Station 1)
Directional control
-+ -+ -+ -+ -+
33.2
valve
20
M5 x 0.8
(A, B port)
Flow control
equipment
12
24
MAX.13.5 43.5
control equipment
(Pitch)
Filter, Pressure
P = 16 23
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
Approx. 300
MAX.10
equipment
123[127.4]
107[111.4]
87.4[91.8]
141.2
121.2
106.4
143
125.2
105.2
90.4
127
43.7[45.9]
53.5[55.7]
45.2
52.6
62.6
63.5
Pressure switch
0.6
0.6
35.6
0.6
0.6
33.2
53.1
0.6
62.6
0.6
48.6[55.6]
73.9
81.4
Clean gas filter
531
Manifold specifications 10-SYJ5000
Type 41: Side ported / 10-SS5YJ5-41- Stations -M5첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
L1
4.5 L2 Manual override
2-ø5.5
(For mounting)
12
60.2[62.4]
59.6[61.8]
(DIN: 38.7)
(DIN: 22.1) (DIN: 39.3)
87.2[91.6]
103.2[107.6]
R
B B B B B
38.1
21
35
5.5 37.5
3.5 17.5
P
A A A A A
7
20.9
(Pitch)
18 P = 16
-+ -+ -+
37.2
A A
18.5
24
B B
5.5
(Pitch)
23 P = 16
M5 x 0.8
(A, B port)
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
85.4
77.9
52.6[59.6] 66.6
0.6
M8 x 1
0.6
57.1
37.2
0.6
39.6
0.6
0.6
0.6
69.5[71.7]
59.7[61.9]
79.5
78.6
68.6
61.2
107[111.4]
87.4[91.8]
103.4[107.8]
123[127.4]
125.2
105.2
127
90.4
141.2
121.2
106.4
143
3.5
3.5
3.5
3.5
Pg7
MAX.10
(Lead wire length)
ø3.5 to ø7
532
Manifold specifications 10-SYJ5000
Type 42: Side ported / 10-SS5YJ5-42- Stations -01, C6
N7 첸 ∗ [ ]: AC
Grommet (G) C6
01첸 N7 첸(With built-in One-touch fitting)
Air cylinder
(Lead wire length)
Approx. 300
L1 Manual override
6.5 L2
2-ø6.5
Rotary actuator
(For mounting)
17.5 17.5
65.2[67.4]
64.6[66.8]
(DIN: 43.7)
(DIN: 44.3)
87.2[91.6]
103.2[107.6]
B B B B B
43.9
24
24
44
0.5 42.5
43.1
23
P
A A A A A
10.4
(DIN: 1.7)
10.5
Air gripper
15.9
(DIN: 17.1)
1/4 1/4
(Pitch) (P, R port)
24.5 P = 17 (P, R port)
(Station 1) (Station n)
Directional control
(Station 1) (Station n)
(Light/surge voltage suppressor) Built-in speed controller (Light/surge voltage suppressor)
valve
MAX.13.5 56.5
61.6[68.6]
61.6[68.6]
-+ -+ -+ -+ -+ -+
46.2
46.2
A A A A
33
33
24.5
25
B B B B
6 1
8.5
8.5
Flow control
equipment
(Pitch) (Pitch)
24.5 P = 17 1/8 29 P = 16 One-touch fitting
(A, B port) (A, B port)
Applicable tubing
O.D.: ø6,ø1/4"
control equipment
Filter, Pressure
∗ Other dimensions are the same as the grommet type.
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
94.4
75.6
46.2
0.6
0.6
48.6 0.6
0.6
74.5[76.7]
64.7[66.9]
84.5
83.6
73.6
107[111.4]
87.4[91.8]
103.4[107.8]
66.2
123[127.4]
125.2
105.2
90.4
127
141.2
121.2
106.4
143
Air preparation
equipment
MAX.10
Pg7
Pressure switch
ø3.5 to ø7
533
Manifold specifications 10-SYJ5000
C4
Type 43: Side ported / 10-SS5YJ5-43- Stations - N3 첸 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
L1
4.5 L2 Manual override
2-ø5.5
(For mounting)
12 1/8
(P, R port)
62.6[64.8]
62[64.2]
(DIN: 4.3) (DIN: 41.1)
(DIN: 41.7)
87.2[91.6]
103.2[107.6]
R
B B B B B
40.5
17.5
36.9
3.1 39.9
1.1 20.2
P
P
A A A A A
11.4
(4.4)
18.5
(DIN: 19.7)
(Pitch)
18 P = 16
-+ -+ -+
37.2
A A
24
18
B B
6
(Pitch)
22.3 P = 16 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4,ø5/32"
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
85.4
52.6[59.6] 77.9
66.6 M8 x 1 57.1
0.6
0.6
37.2
39.6
0.6
0.6
0.6
0.6
72[74.2]
62.2[64.4]
81.1
82
63.7
71.1
125.2
90.4
127
107[111.4]
141.2
106.4
87.4[91.8]
105.2
143
123[127.4]
103.4[107.8]
121.2
1
Pg7
MAX.10
ø3.5 to ø7
534
Manifold specifications 10-SYJ5000
Air cylinder
C4, N3
Manual override C6, N7
L1
M5 x 0.8 L2 9 (With built-in One-touch fitting)
Rotary actuator
(A, B port) 4-ø4.5
-+
(For mounting)
13.4
-+ -+
15.2
2
123[127.4]
107[111.4]
10 18.5
23.5
R
R One-touch fitting
16.5 16.5
A
A
45.6
(A, B port)
77.6 [79.8]
45
49
77 [79.2]
P
Applicable tubing
65
82.8
16.5
B
Air gripper
R
ø6, ø1/4"
-+ -+ -+ -+ -+
Triangle mark
1/8 (3.2) 52.8
(Pitch)
P = 17.5 21 (P, R port)
Directional control
(Station n) (Station 1)
(Light/surge voltage suppressor)
valve
48.6[55.6]
5.8
25.1
20
Flow control
26 pins MIL type with strain relief Stations n 3 stations 4 5 6 7 8 9 10 11 12 stations
equipment
(Conforming to MIL-C-83503) L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 59 76.5 94 111.5 129 146.5 164 181.5 199 216.5
control equipment
M5 x 0.8
Filter, Pressure
5.5
P = 17.5 26
(A, B port)
18.5
-+ -+
5.5
3.5
38.1 20.9
12
123[127.4]
7
107[111.4]
17.5
A A A A A
Air preparation
5.5
37.5
equipment
69.5 [71.7]
70.1 [72.3]
21
35
51
MAX.13.5
68.8
B B B B B
-+ -+ -+ -+ -+
P = 17.5 21
(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6[59.6]
7.8
29.1
535
Manifold specifications 10-SYJ5000
C4
10-SS5YJ5-43P- Stations - N3 첸
One-touch fitting (Pitch)
(A, B port) P = 17.5 25.3
6
Applicable tubing
O.D.: ø4, ø5/32"
18
L1 Built-in speed controller
Manual override L2 7.5
-+
-+ -+
(4.4)
11.4
12
3.1
1.1
40.5 18.5
123 [127.4]
107 [111.4]
20.2
A A A A A
5.5
36.9
39.9
17.5
71.9 [74.1]
72.5 [74.7]
52.9
MAX.13.5
70.7
B B B B B
-+ -+ -+ -+ -+
(Station n) (Station 1)
(Light/surge voltage suppressor)
52.6 [59.6]
7.8
29.1
24
536
Series10-SYJ7000
Rubber seal
5 port solenoid valve
Air cylinder
Specifications
Fluid Air
2 position single 0.15 to 0.7
Operating pressure
2 position double 0.1 to 0.7
range (MPa)
3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (with no freezing. Refer to page 714.)
Rotary actuator
Response time ms 2 position single, double 30 or less
(0.5MPa) Note 1) 3 position 60 or less
Max. operating 2 position single, double 5
frequency (Hz) 3 position 3
Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust for the pilot and main valve
Body ported Lubrication Not required
Mounting orientation Unrestricted
Air gripper
Impact/Vibration resistance m/s2 Note 2) 150/30
Enclosure Dustproof (∗DIN terminal, M8 connector conforms to IP65.)
∗ Based on IEC60529
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature : 20°C, at rated voltage,
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
Directional control
and at the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep between 45 and 2000Hz. Test was
valve
performed in the axial direction and at the right angles to the main valve and armature in both
energized and de-energized states every once for each condition. (Value in the initial state)
Base mounted
Solenoid specifications
Flow control
equipment
JIS Symbol
Body ported Base mounted Grommet (G), (H)
2 position single 2 position single solenoid
L plug connector (L)
M plug connector (M)
(A)(B) (B)(A) Electrical entry
4 2 2 4 DIN terminal (D)
M8 connector (W)
control equipment
Filter, Pressure
5 1 3 3 1 5 G, H, L, M, W D
(R1) (P) (R2) (R2) (P) (R1)
DC 24, 12, 6, 5, 3 24, 12
Coil rated voltage V
2 position double 2 position double solenoid AC 50/60Hz 100, 110, 200, 220
(A)(B) (B)(A) Allowable voltage fluctuation ±10% of rated voltage ∗
4 2 2 4
Standard 0.35 {With indicator light: 0.4 (DIN connector with indicator light: 0.45)}
Power consumption (W) DC
With power saving circuit 0.1 (With indicator light only)
5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1) 100V 0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)
4 2 2 4
equipment
∗ For 115 and 230 VAC, the allowable voltage fluctuation is -15% to +5% of rated voltage.
∗ For the allowable voltage fluctuation for S, Z and T types (with power saving circuit), please observe the
5 1 3 3 1 5 following range because they have voltage drop due to internal circuit.
(R1) (P) (R2) (R2) (P) (R1) S and Z types 24 VDC: –7% to +10%
12 VDC: –4% to +10%
3 position pressure center 3 position pressure center T type 24 VDC: –8% to +10%
(A)(B) (B)(A) 12 VDC: –6% to +10%
4 2 2 4
Pressure switch
5 1 3 3 1 5
(R1) (P) (R2) (R2) (P) (R1)
Made to
Order Made to order specifications (Refer to page 557 for details.)
Clean gas filter
537
5 port solenoid valve Series 10-SYJ7000
3 position Exhaust center 1.2 0.48 0.35 3.4[1.3] 0.36[0.57] 0.86[0.41] 188(108) 190(110) 232(152) 198(118)
Pressure center 3.3[0.85] 0.43[0.54] 0.78[0.25] 2.1 0.45 0.56
Single 165(85) 166(86) 187(107) 170(90)
2 position 2.3 0.41 0.61 2.9 0.35 0.74
Double 178(98) 180(100) 222(142) 188(108)
10-SYJ7첸43-첸-02 Closed center 1/4 1/4 1.9 0.46 0.50 2.2 0.44 0.60
3 position Exhaust center 1.3 0.45 0.35 3.7[1.4] 0.27[0.56] 0.87[0.43] 188(108) 190(110) 232(152) 198(118)
Pressure center 3.6[0.83] 0.23[0.55] 0.84[0.25] 2.1 0.47 0.58
Note 1) [ ] denotes normal position. Exhaust center: 4/2 → 5/3, Pressure center: 1 → 4/2
Note 2) ( ): Without sub-plate
Note 3) For DC voltages. For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types.
538
5 port solenoid valve Series 10-SYJ7000
How to Order
Light/Surge voltage suppressor
Electrical entry for G, H, L, M, W Electrical entry for D
Type of actuation
Air cylinder
Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
1 2 position single solenoid S With surge voltage suppresser S With surge voltage suppresser (Non-polar type)
2 2 position double solenoid Z With light/surge voltage suppresser Z With light/surge voltage suppresser (Non-polar type)
3 3 position closed center R With surge voltage suppressor (Non-polar type) ∗ "DOZ" is not available.
∗ For AC voltage valves, there is
Bracket
4 3 position exhaust center U With light/surge voltage suppressor (Non-polar type)
no "S" option. It is already built-
5 3 position pressure center ∗ For AC voltage valves, there is no "S" option. It is Nil: Without bracket
in to the rectifier circuit.
already built-in to the rectifier circuit. F: With bracket
Rotary actuator
∗ For "R" and "U", DC voltage is only available.
∗ Power saving circuit is only available in the "Z" Thread type
type.
Nil Rc
F G
Rated voltage
N NPT
DC specifications AC specifications (50/60Hz)
T NPTF
5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC A, B port size
V 6 VDC 3 110 VAC [115 VAC] 01 1/8
Air gripper
Note) Do not remove the factory
S 5 VDC 4 220 VAC [230 VAC] C6 One-touch fitting for ø6 installed bracket from
R 3 VDC ∗ For type "W첸", C8 One-touch fitting for ø8 models with the bracket
∗ DC specifications of option. Removal of the
DC voltage is N7 One-touch fitting for ø1/4" bracket will cause the
type "D" and "DO" is only available.
only available with N9 One-touch fitting for ø5/16" valve to leak. Brackets
(For manifold type 20, 21) 12 and 24 V DC. cannot be retrofitted.
Directional control
Body ported 10 SYJ7 1 23 5 M 01
valve
Base mounted 10 SYJ7 2 43 5 M
Flow control
Thread type
equipment
Nil Rc
Coil specifications Manual override F G
Nil Standard N NPT
Nil: Non-locking push
With power saving circuit type T NPTF
T
<For 24 and 12 VDC only>
control equipment
∗ Power saving circuit is
Filter, Pressure
Sub-plate, 40, 41, 42
not available in the
manifold Port size
case of "D", "DO" or
"W첸" type. Nil: Without sub-plate
D: Push-turn locking
slotted type
G: Lead wire L: With lead M: With lead wire MN: Without D: With connector WO: Without
equipment
length wire (length (length 300 mm) lead wire connector lever type
300 mm 300 mm)
+- +-
Pressure switch
H: Lead wire LN: Without LO: Without MO: Without DO: Without W첸: With connector
length 600 mm lead wire connector connector connector cable Note 1)
539
5 port solenoid valve Series 10-SYJ7000
10 V111 5 G 10 V115 5 D
Clean series Clean series
Light/Surge voltage suppressor
Coil specifications Without light/surge voltage suppressor
Rated voltage
Nil
Nil Standard 5 24 VDC
S With surge voltage suppressor
With power saving circuit 6 12 VDC
T Z With light/surge voltage suppressor Light/surge voltage suppressor
<24 and 12 VDC only> 1 100 VAC 50/60Hz
R With surge voltage suppressor (Non-polar type) 2 200 VAC 50/60Hz Nil Without light/surge voltage suppressor
∗ Power saving circuit is U With light/surge voltage suppressor (Non-polar type) 110 VAC 50/60Hz S With surge voltage suppressor (Non-polar type)
not available in the 3
∗ For AC voltage valves, there is no [115 VAC 50/60Hz] Z With light/surge voltage suppressor (Non-polar type)
case of "W첸" type.
"S" option. It is already built-in to 4 220 VAC 50/60Hz ∗ "DOZ" is not available.
the rectifier circuit. [230 VAC 50/60Hz] ∗ For AC voltage valves, there
Rated voltage ∗ For "R" and "U", DC voltage is only is no "S" option. It is already
5 24 VDC available. built-in to the rectifier circuit.
∗ Power saving circuit is only available
6 12 VDC
in the "Z" type.
V 6 VDC
S 5 VDC
R 3 VDC Electrical entry Electrical entry
1 100 VAC 50/60Hz G Grommet (Lead wire length 300 mm) D With connector
DIN
2 200 VAC 50/60Hz H Grommet (Lead wire length 600 mm) DO terminal Without connector
110 VAC 50/60Hz L With lead wire
3 Note) Do not replace 10-V111
[115 VAC 50/60Hz] L plug
LN
connector Without lead wire (G, H, L, M, W) to 10-
220 VAC 50/60Hz LO Without connector V115 (DIN terminal) and
4
[230 VAC 50/60Hz] M With lead wire vice versa when
∗ For type "W첸", DC M plug replacing pilot valve
MN
voltage is only connector Without lead wire Note 1) Be sure to enter a assembly only.
MO Without connector symbol of the cable
available.
WO M8 Without connector cable length with reference
W첸 connector With connector cable Note 1) to page 562.
∗ For connector cable of M8
connector, refer to page 562.
How to Order L/M Plug Connector Assembly How to Order M8 Connector Cable
For DC :SY100-30-4A-
V100-49-1-
For 100 VAC :SY100-30-1A-
For 200 VAC :SY100-30-2A- Cable length
1 300mm
For other voltages of AC :SY100-30-3A- 2 500mm
3 1000mm
Without lead wire 4 2000mm
(With connector and 2 of sockets only) :SY100-30-A 7 5000mm
540
5 port solenoid valve Series 10-SYJ7000
2 position single ∗ [ ]: AC
Air cylinder
44
2-ø4.5 36 4
(For mounting)
26
34
- +
G: Approx. 300
82[84.2] H: Approx. 600
Rotary actuator
59.8 (Lead wire length) 24.1
28.3 39.5[46.5]
13
3
A B
Manual override
2-ø3.2 17
(For manifold mounting) 1/8
85.6[87.8]
35 (A, B port)
Air gripper
2-ø3.2 (Light/surge voltage suppressor)
35
(For mounting) (Bracket)
3.6
-+
28
25
16.1
21
Directional control
31.5[38.5]
valve
Built-in One-touch fitting:
10-SYJ7123-첸GH 첸첸- C6, N7
C8, N9 첸 (-F)
R1 P R2
28.3
1.6
18
1/8 27.2 A B
(P, R1, R2 port)
Flow control
equipment
17
One-touch fitting
(4.9)
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
: ø8, ø5/16"
control equipment
36
Filter, Pressure
(3.6)
L plug connector (L) M plug connector (M) DIN Terminal (D): M8 connector (WO):
ø3.5 to ø7
65
31.5[38.5]
MAX.10
57.5
16.1 46.2
31.1 M8 x 1 36
Air preparation
equipment
Pg7
91.9[94.1]
101.9
82.1[84.3]
101
Pressure switch
91
83.6
77.1
61.1
35
35
35
35
28.3
28.3
28.3
28.3
21 21 21 21
(3.6)
(3.6)
(3.6)
(3.6)
541
5 port solenoid valve Series 10-SYJ7000
2 position double ∗ [ ]: AC
G: Approx. 300
107.4[111.8] H: Approx. 600
63 (Lead wire length)
3
13
A B A B
Manual override
17 17
2-ø3.2 35 1/8 (A, B port)
(For manifold mounting)
One-touch fitting
(4.9)
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"
36
-+
28
25
16.1
21
31.5[38.5]
1.6
R1 P R2
18
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7223-씲L씲씲-01씲 10-SYJ7223-씲M씲씲-01씲 10-SYJ7223-씲D씲씲-01씲 10-SYJ7223-씲WO씲씲-01씲
(Lead wire length)
Approx. 300
65
31.5[38.5]
MAX.10
57.5
16.1 46.2
31.1 M8 x 1 36
Approx. 300 42.6[49.6] 18.5
(Lead wire length)
2-ø3.2
(For mounting) 2-ø3.2
127.2[131.6]
147.2
125.4
110.6
97.6
65.6
35
35
35
35
21
21
21 25
21 25
28 Pg7
25 25 28
Applicable cable O.D.
28 28
ø3.5 to ø7
542
5 port solenoid valve Series 10-SYJ7000
Air cylinder
G: Approx. 300
122[126.4] H: Approx. 600
(Lead wire length)
Rotary actuator
54.5[56.7]
45.3 32.3
3
13
A B A B
Manual override
17 17
2-ø3.2 1/8 (A, B port)
(For manifold mounting) 35
One-touch fitting
(4.9)
Air gripper
(A, B port)
2-ø3.2 (Light/surge voltage suppressor)
35 Applicable tubing O.D.: ø6, ø1/4"
(For mounting)
: ø8, ø5/16"
36
- +
28
25
16.1
21
Directional control
31.5[38.5]
valve
1.6
R1 P R2
18
Flow control
equipment
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3 3
10-SYJ7 45 23-첸L첸첸-01첸 10-SYJ7 45 23-첸M첸첸-01첸 10-SYJ7 45 23-첸D첸첸-01첸 10-SYJ7 45 23-첸WO첸첸-01첸
(Lead wire length)
Approx. 300
65
31.5[38.5]
MAX.10
57.5
16.1
74.4
54.6[56.8]
73.5
63.5
56.1
49.6
Air preparation
33.6
equipment
141.8[146.2]
122.2[126.6]
35
35
35
35
161.8
160
140
46.6
62.6
28
28
28
Pg7 28
Clean gas filter
543
5 port solenoid valve Series 10-SYJ7000
2 position single ∗ [ ]: AC
22
12
34 8.5
2-ø4.3
Manual override B A (For mounting)
27
A
B
R2 P R1
- +
54
42.1
25.5
20
12
11.5
18 1/4 (R1, R2 port) 22 22
34 31.5
63
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7143-첸L첸첸- 0102 첸 10-SYJ7143-첸M첸첸- 0102 첸 10-SYJ7143-첸D첸첸- 01
02 첸 10-SYJ7143-첸WO첸첸- 01
02첸
(Lead wire length)
ø3.5 to ø7
91
MAX.10
57.5[64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
44.5
68.6[75.6] Approx. 300
20 20 20 20
Pg7
95.1[97.3]
104.2
85.3[87.5]
94.2
86.8
80.3
22
22
22
22
64.3
63
63
63
63
22
22
22
22
31.5
31.5
31.5
31.5
3.2
3.2
3.2
3.2
544
5 port solenoid valve Series 10-SYJ7000
2 position double ∗ [ ]: AC
Air cylinder
22
12
Rotary actuator
G: Approx. 300
H: Approx. 600 107.4[111.8]
(Lead wire length) 63
Air gripper
B A
27
A
B
Manual override R2 P R1
2-ø4.3 34 8.5
(For mounting)
Directional control
(Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port)
valve
57.5[64.5]
- +
42.1
25.5
20
12
11.5
22 22
Flow control
18 1/4 (R1, R2 port)
equipment
34 31.5
63
control equipment
Filter, Pressure
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
10-SYJ7243-첸L첸첸- 0102첸 10-SYJ7243-첸M첸첸- 0102 첸 10-SYJ7243-첸D첸첸- 01
02 첸 10-SYJ7243-첸WO첸첸- 01
02첸
91
57.5[64.5] 83.5
42.1 72.2
57.1 62 M8 x 1
(Lead wire length)
68.6[75.6] Approx. 300 44.5
Air preparation
equipment
20 20 20 20
Pg7
127.2[131.6]
107.6[112]
22
22 22
22
22
147.2
145.4
110.6
125.4
97.6
65.6
63
63
63
63
22
22
22
31.5
31.5
31.5
31.5
Pressure switch
545
5 port solenoid valve Series 10-SYJ7000
3
Grommet (G), (H): 10-SYJ7 45 43-첸 GH첸첸- 01
02 첸
22
12
G: Approx. 300
H: Approx. 600 122[126.4]
(Lead wire length) 2-ø4.3 36[38.2]
(For mounting)
B A
27
A
B
R2 P R1
Manual override 34 8.5
63.8 13.8
- +
42.1
25.5
20
12
11.5
L plug connector (L): M plug connector (M): DIN Terminal (D): M8 connector (WO):
3 3 3 3
10-SYJ7 45 43-첸L첸첸- 01
02 첸 10-SYJ7 45 43-첸M첸첸- 01
02 첸 10-SYJ7 45 43-첸D첸첸- 01
02첸 10-SYJ7 45 43-첸WO첸첸- 01
02첸
(Lead wire length)
91
57.5[64.5] 83.5
42.1 72.2
Pg7 62 M8 x 1
(Lead wire length) 57.1
68.6[75.6] Approx. 300 44.5
20 20 20 20
141.8[146.2]
87.6
122.2[126.6]
81.1
22
22
22 22
22
65.1
161.8
63
63
63
63
160
140
22
22
22
31.5
31.5
31.5
31.5
15.1
45.9[48.1]
31.1
12 12 12 12
55
MAX.10
546
Series 10-SYJ7000 Manifold specifications
Air cylinder
Manifold standard
Manifold specifications
Rotary actuator
Manifold type Single base / B mount
P (SUP) / R (EXH) Common SUP / Common EXH
Valve stations 2 to 15 stations 2 to 20 stations
A, B port porting Location Valve Base Base
specifications Direction Top Bottom Side
P, R port 1/8 1/4
Air gripper
1/8 C6 (One-touch
Port size A, B port C6 (One-touch fitting for ø6) 1/8 fitting for ø6)
C8 (One-touch fitting for ø8) C8 (One-touch
fitting for ø8)
Directional control
Flow characteristics
valve
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
1/8 1/8 2.2 0.35 0.57 2.3 0.26 0.55
Body
Flow control
equipment
ported
10-SS5YJ7-20 1/8 C6 1.4 0.32 0.37 2.0 0.25 0.49
for
10-SYJ7첸23 1/8 C8 1.7 0.38 0.45 2.1 0.25 0.51
1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
internal
pilot
10-SS5YJ7-21 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Base 10-SS5YJ7-40 1/4 1/8 2.1 0.28 0.51 2.5 0.23 0.59
control equipment
mounted 10-SS5YJ7-41 10-SYJ7첸43 1/4 1/8 2.0 0.30 0.50 2.2 0.30 0.55
Filter, Pressure
for internal 10-SS5YJ7-42-C6 1/4 C6 1.5 0.32 0.38 2.2 0.23 0.52
pilot 10-SS5YJ7-42-C8 1/4 C8 1.9 0.24 0.46 2.2 0.26 0.53
Note) Value at manifold base mounted, 2 position single operating
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the
Pressure switch
547
Manifold specifications 10-SYJ7000
Flow characteristics
Flow characteristics
Port size
1→4/2 (P→A/B) 4/2→5/3 (A/B→R)
Manifold
1(P), 5/3(R) 2(B), 4(A) C C
b Cv b Cv
port port [dm3/(s·bar)] [dm3/(s·bar)]
Body ported 10-SS5YJ7-21P-01 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
for internal 10-SS5YJ7-21P-C6 10-SYJ7첸23 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
pilot 10-SS5YJ7-21P-C8 1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Note) Value at manifold base mounted, 2 position single operating
548
Manifold specifications 10-SYJ7000
Manifold standard
Common SUP / Common EXH
Type 20 (5 port / Body ported) How to Order
A, B port 10-SS5YJ7-20- 05 -
Air cylinder
P,R port
thread type
Stations
Nil Rc
02 2 stations Applicable solenoid valve
00F G 01
P port 1/8 : : 10-SYJ7첸23-첸첸첸첸-C6
00N NPT C8
15 15 stations 00T NPTF
R port 1/8
Applicable blanking
Rotary actuator
Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
plate assembly
Type 21 (5 port / Body ported) How to Order SYJ7000-21-1A
A, B port 10-SS5YJ7-21- 05 - Applicable individual
P,R port EXH spacer assembly
Stations thread type
02 2 stations SYJ7000-17-1A
Nil Rc
P port 1/4 : :
00F G
20 20 stations
Air gripper
00N NPT
R port 1/4 00T NPTF
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Directional control
Stations A, B port size Thread type
02 2 stations 01 1/8 Nil Rc
valve
: : F G
R port 1/4 N NPT
20 20 stations
T NPTF
A, B port 1/8
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port. Applicable solenoid valve
Type 41 (5 port / Base mounted) How to Order 10-SYJ7첸43-첸첸첸첸
Flow control
10-SS5YJ7-41- 05 - 01
equipment
Applicable blanking
plate assembly
P port 1/4 Stations A, B port size Thread type SYJ7000-21-1A
02 2 stations 01 1/8 Nil Rc Applicable individual
: : F G EXH spacer assembly
N NPT SYJ7000-17-2A
20 20 stations
control equipment
Filter, Pressure
A, B port 1/8 T NPTF
R port 1/4 Applicable individual
Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. SUP spacer assembly
Type 42 (5 port / Base mounted) How to Order SYJ7000-16-2A
10-SS5YJ7- 42- 05 - C6
Stations A, B port size Thread type
02 2 stations C6 One-touch fitting for ø6 Nil Rc
A, B port
Applicable blanking
Stations P, R port plate assembly
thread type SYJ7000-21-3A
P port 1/4 03 3 stations
Nil Rc
: : Applicable connector
00F G
12 12 stations 00N NPT assembly
00T NPTF Refer to page 548.
Clean gas filter
R port 1/4
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
549
Manifold specifications 10-SYJ7000
<Manifold option>
Combinations of solenoid valve, manifold gasket and manifold base Mix installation of 10-SYJ700 and 10-SYJ7000 valves on the same manifold
Round head combination screw Round head combination screw 앬 Use of an adapter plate makes it possible to mount series 10-SYJ700 on the manifold bases of
M3 x 31 series 10-SYJ7000.
M3 x 31
앬 When mounting the 10-SYJ700 valve on the 10-SYJ7000 manifold, the 10-SYJ700 solenoid
Matt nickel plated Matt nickel plated must be positioned on the same side of a single solenoid of the 10-SYJ7000.
(With spring washer) (With spring washer) 앬 For base mounted style, the A port of the 3 port valve become the B port of manifold base.
Gasket Gasket
DXT199-21-10 DXT199-21-11
Round head
Applicable base Applicable base combination screw
· 10-SS5YJ7-20 · Sub-plate Round head
· 10-SS5YJ7-21 · 10-SS5YJ7-40 combination screw
· 10-SS5YJ7-41
· 10-SS5YJ7-42
Individual EXH spacer assembly
SYJ7000-17-1 A Thread type
SYJ7000-17-2 A Thread type
Round head Nil Rc Round head Nil Rc
F G F G
Gasket
combination screw combination screw
N NPT N NPT
T NPTF T NPTF
Round head
7
Round head combination screw
7
combination screw
B
B
O-ring
Manifold gasket
15
15
Individual R2 Individual R2
exhaust spacer exhaust spacer Applicable base Applicable base
· 10-SS5YJ7-20 · 10-SS5YJ7-40
R
R1 R1
R
· 10-SS5YJ7-21 · 10-SS5YJ7-41
· 10-SS5YJ7-42
Manifold Manifold
gasket gasket Blanking plate assembly
Applicable base Applicable base SYJ7000-21-1A
· 10-SS5YJ7-20 · 10-SS5YJ7-40
Round head combination screw
· 10-SS5YJ7-21 · 10-SS5YJ7-41
· 10-SS5YJ7-42
Individual SUP spacer assembly
SYJ7000-16-2 A Blanking plate Applicable base
· 10-SS5YJ7-20
Round head · 10-SS5YJ7-21
combination screw Gasket · 10-SS5YJ7-40
Thread type · 10-SS5YJ7-41
Nil Rc SYJ7000-21-3A · 10-SS5YJ7-42
F G
B
Blanking plate
Gasket
15
Individual
SUP spacer
P
Applicable base
Manifold Dust cap
· 10-SS5YJ7-40
gasket
· 10-SS5YJ7-41
Applicable base
· 10-SS5YJ7-42
Caution · 10-SS5YJ7-21P
Mounting screw tightening torque Use caution to the assembly orientation of solenoid valves, gasket, and optional parts.
M3: 0.8N·m
550
Manifold specifications 10-SYJ7000
Type 20: Top ported / 10-SS5YJ7-20- Stations -00 ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
Air cylinder
L1 4-ø4.5
L2 6 (For mounting)
(DIN: 7.8)
(DIN: 21.6)
Rotary actuator
15.5
3
6.5
3.3
20.3
8
122[126.4]
107.4[111.8]
17 16.5
A
25
R
(DIN: 57.8)
(DIN: 58.6)
17 17
56.5
78.7[80.9]
57.3
50
79.5[81.7]
P
P
R
R
Air gripper
1/8 (P, R port)
Directional control
Built-in One-touch fitting
valve
(Station n) (Station 1)
-+ -+ -+ -+ -+
Flow control
equipment
ø8, ø5/16"
40.1
23.5
control equipment
(4.9) 60
Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
(Lead wire length)
ø3.5 to ø7
55.5[62.5] 89
40.1 Pg7 81.5
(Lead wire length)
70.2
Approx. 300 66.6[73.6] M8 x 1 Air preparation
equipment
3.3
3.3
3.3
3.3
161.8
141.8[146.2]
122.2[126.6]
127.2[131.6]
107.6[112]
125.2
160
140
145.4
147.2
125.4
110.6
78.8[81]
88.6[90.8]
80.3
87.7
97.7
98.6
Pressure switch
0.8
0.8
42.5
0.8
0.8
60
0.8
0.8
551
Manifold specifications 10-SYJ7000
Type 21: Top ported / 10-SS5YJ7-21- Stations (-00 ) ∗ [ ]: AC
Grommet (G)
(Lead wire length)
Approx. 300
L1
4-ø4.5
L2 10 (For mounting)
(DIN: 2.8)
(DIN: 16.6)
16.5
3 11.5
15.3
1.5
122[126.4]
107.4[111.8]
R
A
30
R
(DIN: 62.8)
(DIN: 63.6)
21
61.5
83.7[85.9]
62.3
84.5[86.7]
17
21
60
P
P
21
R
R
(Station n) (Station 1)
-+ -+ -+ -+ -+
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
43.1
26.5
(4.9) 63
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
Applicable cable O.D.
(Lead wire length)
Approx. 300
ø3.5 to ø7
MAX.10
58.5[65.5] 92
84.5
43.1 Pg7
73.2
(Lead wire length)
Approx. 300 69.6[76.6] M8 x 1
141.8[146.2]
122.2[126.6]
127.2[131.6]
107.6[112]
161.8
125.2
160
140
145.4
125.4
110.6
83.8[86]
147.2
93.6[95.8]
85.3
92.7
102.7
103.6
0.8
0.8
45.5
0.8
0.8
63
0.8
0.8
552
Manifold specifications 10-SYJ7000
Type 40: Bottom ported / 10-SS5YJ7-40- Stations -01 ∗ [ ]: AC
Air cylinder
4-ø4.5
L2 10 (For mounting)
16.5
(DIN: 16.6)
(DIN: 2.8)
11.5
15.3
0.5
1.5
Rotary actuator
122[126.4]
107.4[111.8]
R
A A A A A
(DIN: 63.6)
30
R
(DIN: 62.8)
21 21
83.7[85.9]
84.5[86.7]
62.3
61.5
21
60
P
P
B B B B B
R
R
Air gripper
Manual override (Pitch)
P = 19 23.5
(Station n) (Station 1)
(Light/surge voltage suppressor)
-+ -+ -+ -+ -+
58[65]
Directional control
42.6
26
valve
B B
19
40
Flow control
equipment
A A
(Pitch) 2
23.5
control equipment
P = 19
Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
Applicable cable O.D.
(Lead wire length)
Approx. 300
ø3.5 to ø7
MAX.10
91.5
122.2[126.6]
equipment
127.2[131.6]
107.6[112]
161.8
125.2
160
140
145.4
147.2
125.4
110.6
83.8[86]
93.6[95.8]
85.3
92.7
102.7
103.6
Pressure switch
0.8
0.8
45
0.8
0.8
62.5
0.8
0.8
553
Manifold specifications 10-SYJ7000
Type 41: Side ported / 10-SS5YJ7-41- Stations -01 ∗ [ ]: AC
Grommet (G)
31.5
20.5
85.2[87.4]
86[88.2]
107.4[111.8]
R
R
B B B B B
(DIN: 65.1)
(DIN: 64.3)
122[126.4]
19 19
63.8
19
63
60
P
P
31.5
22
A A A A A
R
R
(DIN: 15.1)
4-ø4.5
(Pitch)
29 P = 20 (For mounting)
Manual override
(Station 1) (Station n)
(Light/surge voltage suppressor)
-+ -+ -+
73[80]
57.6
A A
10.5
41
30.5
B B
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
106.5
99
73[80] 87.7
M8 x 1 77.5
0.8
0.8
57.6 60
0.8
0.8
0.8
0.8
95.1[97.3]
105.1
104.2
85.3[87.5]
127.2[131.6]
94.2
107.6[112]
86.8
141.8[146.2]
122.2[126.6]
145.4
147.2
125.4
110.6
161.8
125.2
160
140
84.1[91.1]
Approx. 300
(Lead wire length)
(Lead wire length)
MAX.10
ø3.5 to ø7
554
Manifold specifications 10-SYJ7000
Type 42: Side ported / 10-SS5YJ7-42- Stations - C6,N7
C8,N9 ∗ [ ]: AC
Grommet (G)
Air cylinder
L1
Manual override
14 L2
4-ø4.5
(For mounting) 32.5
19
Rotary actuator
85.9[88.1]
85.1[87.3]
107.4[111.8]
(DIN: 64.2)
R
B B B B B
R
(DIN: 65)
122[126.4]
18 18.5
62.9
63.7
59.9
21.9 19
P
P
31.4
A A A A A
R
R
(DIN: 15.2)
(4.9)
13.9
Air gripper
1/4 (P, R port)
(Pitch)
29 P = 19
Directional control
(Station 1) (Station n)
(Light/surge voltage suppressor)
valve
-+ -+ -+
74[81]
58.6
A A
42
29.5
8.5
B B
Flow control
equipment
8 (Pitch)
25 P = 19 One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
control equipment
Filter, Pressure
L plug connector (L) M plug connector (M) DIN Terminal (D) M8 connector (WO)
107.5
74[81] 100 M8 x 1
88.7
78.5
58.6
0.8
61
0.8
0.8
0.8
95[97.2]
85.2[87.4]
104.1
105
127.2[131.6]
94.1
107.6[112]
141.8[146.2]
122.2[126.6]
86.7
145.4
147.2
125.4
110.6
161.8
125.2
160
140
Air preparation
equipment
85.1[92.1]
Approx. 300
Pressure switch
ø3.5 to ø7
555
Manifold specifications 10-SYJ7000
- +
4-ø4.5
(For mounting)
- + - +
16.5
1/8 (A, B port)
1.5
15.3
11.5
141.8[146.2]
127.2[131.6]
17 21.5
21 19.5
R
R
30
A
21 21
61.5
62.3
93.6[95.8]
94.4[96.6]
60
P
P
93.8
B
R
R
16
- + - + - + - + - +
(Station n) (Station 1)
(Light/surge voltage suppressor)
58.5[65.5]
32.3
26.5
28.5
8.8
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø6, ø1/4"
ø8, ø5/16"
(4.9) 63
556
Series 10-SYJ5000/7000
Made to order specifications
DIN terminal connector conforming to EN-175301-803C
(former DIN 43650C) standard
DIN terminal type conforming to DIN 43650C (DIN pitch 8mm) standard
Air cylinder
How to Order Valves
Light/surge voltage suppressor
Type of actuation
Nil Without light/surge voltage suppressor
1 2 position single solenoid
S With surge voltage suppresser
2 2 position double solenoid
Z With light/surge voltage suppresser Bracket
3 3 position closed center
Rotary actuator
∗ "YOZ" is not available. Nil Without bracket
4 3 position exhaust center ∗ For AC voltage valves, there is no "S" F With bracket
5 3 position pressure center option. It is already built-in to the
rectifier circuit. Note) Do not remove the factory
installed bracket from
models with the bracket
Rated voltage A, B port size option. Removal of the
DC specifications AC specifications (50/60Hz) M5 M5 x 0.8 bracket will cause air
5 24 VDC 1 100 VAC 01 1/8 (10- SYJ7000 only) leakage.
6 2
Air gripper
12 VDC 200 VAC C4 One-touch fitting for ø4
3 110 VAC [115 VAC] C6 One-touch fitting for ø6
4 220 VAC [230 VAC] N3 One-touch fitting for ø5/32"
N7 One-touch fitting for ø1/4
Directional control
Body ported 10 SYJ 5 1 23 5 Y M5
valve
Base mounted 10 SYJ 5 2 43 5 Y
Series Electrical entry Thread type
Flow control
equipment
5 10-SYJ5000 Nil Rc
Y: With connector F G
7 10-SYJ7000
N NPT
T NPTF
Port size
Nil Without sub-plate
control equipment
Filter, Pressure
10-SYJ5000
1 1/8
YO: Without connector 10-SYJ7000
2 1/4 10-SYJ7000
Manual override
Nil Non-locking push type
D Push-turn locking slotted type
DIN terminal 2. D type DIN connector with 9.4 mm pitch between terminals is not interchangeable.
YO Without connector 3. DIN connector except D type has the "N" indication in the end of voltage symbol. In
case of DIN connector without light, "N" is not indicated. Please refer to the name
plate to distinguish.
4. Dimensions are completely the same as D type connector.
5. When exchanging the pilot valve assembly only, "10-V115-첸D" is interchangeable
with "10-V115-첸Y". Do not replace 10-V114 (G, H, L, M, W) to 10-V115-첸D/첸Y
(DIN terminal), and vice versa.
557
Series 10-SYJ3000/5000/7000
Specific Product Precautions 1
Be sure to read before handling.
Warning Warning
When the manual override is operated, connected equipment will Solenoid valves with grommet and L/M type plug connector AC
be actuated. Confirm safety before operating. specificatinos have a built-in rectifier circuit in the pilot section to
operate the DC coil.
왎Non-locking push type (Standard) With 200/220 VAC specification pilot valves, this built-in rectifier
Press in the direction of the arrow. generates heat when energized. The surface may become hot
depending on the energized condition. Therefore, do not touch
the solenoid valves.
LOCK
Locked position
5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
LOCK
PUSH
5 13 5 13
(R1) (P)(R2) (R1) (P)(R2)
558
Series 10-SYJ3000/5000/7000
Specific Product Precautions 2
Be sure to read before handling.
Air cylinder
How to use plug connector Plug connector lead wire length
Caution Caution
Rotary actuator
1. Attaching and detaching connectors Standard length is 300 mm, but the following lengths are also
앬 To attach a connector, hold the lever and connector unit available.
between your fingers and insert straight onto the pins of the
solenoid valve so that the lever's pawl is pushed into the How to Order Connector Assembly
groove and locks.
For DC: SY100 30 4A
앬 To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
Air gripper
For 100 VAC: SY100 30 1A
connector straight out.
Cover
Groove For 200 VAC: SY100 30 2A
Pin
Cover
Groove For other voltages of AC: SY100 30 3A
Directional control
Lever
Pin
DC polarity display
Without lead wire: SY100 30 A Lead wire
valve
-+
Flow control
equipment
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the connector. 25 2500mm
ends of the core wires evenly into the sockets, and then crimp <Example> Lead wire length 2000 mm 30 3000mm
50 5000mm
with a crimping tool. (For DC) For AC
When this is done, take care that the coverings of the lead 10-SYJ3123-5LO-M3 10-SYJ3123-1LO-M3
wires do not enter the core wire crimping area. SY100-30-4A-20 SY100-30-1A-20
control equipment
Filter, Pressure
Use an exclusive crimping tool for crimping.
(For special crimping tools, please contact SMC.)
Core wire crimping area Crimping area
Socket Core wire
Lead wire 0.2 to 0.33mm2
Max. cover diameter: ø1.7 mm
connector. (When they are pushed in, their hooks open and
they are locked automatically.) Then confirm that they are
locked by pulling lightly on the lead wires.
앬 Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket's hook with a stick having a thin tip
Pressure switch
(approx. 1 mm).
If the socket will be used again, first spread the hook
outward.
Socket Connector
Clean gas filter
Lead wire
Hook
559
Series 10-SYJ3000/5000/7000
Specific Product Precautions 3
Be sure to read before handling.
Caution
(For DC)
Grommet, L/M plug connector type DIN terminal
왎Standard type (with polarity) With surge voltage suppresser (DS)
With surge voltage suppresser (첸S)
Varistor
Diode to prevent reverse current
Coil
Red (+)
Varistor
Red (+)
Coil
Coil
Black (–)
DIN terminal has no polarity.
왎Non-polar type
With surge voltage suppresser (첸R)
(–) (+) M8 connector type
Coil
Coil
Varistor
1 3
(+) (–)
3 (–)
· Connect the standard type in accordance with the +, – polarity
indication. Solenoid valve side
(The non-polar type can be used with the connections made Pin wiring diagram With light/surge voltage suppresser(첸Z)
either way.) Diode to prevent reverse current
Coil
make errors in the polarity.
· Be careful about the allowable voltage fluctuation since the 3 (–)
valves with a diode to prevent reverse current has about a 1V
voltage drop. (Refer to the solenoid specifications of each valve 왎Non-polar type
for details.) With surge voltage suppresser (첸R)
(Ground)
· When wiring is done at the factory, positive (+) is red and 1 (–) (+)
negative (–) is black. 4
Coil
왎With power saving circuit Electric circuit (with power saving circuit)
Varistor
3 (+) (–)
Power consumption is de- Red (+)
Diode
Timer circuit
LED
the wattage required to hold With light/surge voltage suppresser (첸U)
the valve in an energized 1 (–) (+)
1 2
state. (Effective energizing Black (–) Solenoid valve side
Coil
560
Series 10-SYJ3000/5000/7000
Specific Product Precautions 4
Be sure to read before handling.
Air cylinder
Surge voltage suppressor How to use DIN Terminal
<For AC> Ground nut
(There is no "S" type because the generation of surge voltage is Tightening torque
Rotary actuator
prevented by a rectifier.) 1.65 to 2.5 N·m
Holding screw
Tightening torque
Grommet, L/M plug connector 0.4 N·m
Washer
With indicator light (첸Z) Grommet
(~)
(Rubber) Housing
Varistor
Coil
(Rating symbol)
Refer to table of
(~) DIN connector part no. (Light mounting
location )
Air gripper
Terminal screw Terminal block
DIN terminal (3 locations) Notch
With indicator light (DZ) Tightening torque
(~)
0.2 to 2.5 N·m
Varistor
Coil
Directional control
(~) DIN connector part no.
NL : Neon ball
valve
Note) Surge voltage suppressor of varistor has residual voltage
corresponding to the protective element and rated voltage. Caution
Therefore, protect the controller side from the surge.
The residual voltage of the diode is approximately 1 V. Without light SY100-61-1
With light
Flow control
Rated voltage Voltage symbol Part no.
equipment
How to use DIN Terminal 24 VDC 24V SY100-61-3-05
12 VDC 12V SY100-61-3-06
control equipment
Filter, Pressure
solenoid valve terminal block.
2. After removing the holding screw, insert a flat head Circuit diagram with light
screwdriver, etc. into the notch on the bottom of the terminal AC circuit DC circuit
block and pry it open, separating the terminal block and the
housing.
3. Loosen the terminal screws (slotted screws) on the terminal
block, insert the cores of the lead wires into the terminals
Also, be sure to tighten the ground nut and holding screw within
their specified torque ranges.
Caution
Changing the entry direction
After separating the terminal block and housing, the cord entry
Pressure switch
side.
Compatible cable
Cord O.D.: ø3.5 to ø7
(Reference) 0.5 mm2, 2 core or 3 core, equivalent to JIS C 3306
561
Series 10-SYJ3000/5000/7000
Specific Product Precautions 5
Be sure to read before handling.
Caution Caution
Connector assembly with dustproof protective cover 1. M8 connector types have an IP65 (enclosure) rating, offering
· Effective to prevent short circuit failure due to the entry of foreign protection from dust and water. However please note that
matter into the connector these products are not intended for use in water.
· Chloroprene rubber for electrical use, which provides outstand- Select a SMC connector cable (V100-49-1-첸) or a FA sensor
ing weather resistance and electrical insulation, is used for the type connector, with M8 threaded 3 pin specifications
cover material. However, do not allow contact with cutting oil, conforming to Nippon Electric Control Equipment Association
etc. Standard, NECA4202 (IEC60947-5-2). Make sure the
· Simple and unencumbered appearance by adopting round- connector O.D. is 10.5 mm or less when used with the Series
shaped cord. 10-SY3000 manifold. If more than 10.5mm, it cannot be
mounted due to the size.
How to Order 2. Do not use a tool to mount the connector, as this may cause
damage. Only tighten by hand. (0.4 to 0.6N)
SY100-68-A 3. Do not apply excessive power greater than 30N to the connec-
Lead wire length tor cable, otherwise IP65 cannot be satisfied.
Nil 300mm
6 600mm
Caution
10 1000mm Failure to meet IP65 performance may result if using alternative
15 1500mm connectors than shown above, or when insufficiently tightened.
20 2000mm
25 2500mm · Connector cable mounting
30 3000mm
50 5000mm
Triangle mark
Arrow mark
Connector assembly with cover: Dimensions
(40) Gray
(10)
(ø4.1)
(6.9)
MConnector cable
· Connector cable for M8 can be ordered as follows:
562
Series 10-SYJ3000/5000/7000
Specific Product Precautions 6
Be sure to read before handling.
Air cylinder
M8 connector Flat ribbon cable manifold
2. To order connector cable only Internal wiring of manifold
Rotary actuator
(Ground) Connector dimensions
4 Brown: 1 Blue: 3 Station 12 Station 4 Station 3 Station 2 Station 1
Coil
ø9
3 1
Black: 4 Side A Side B Side A Side B Side A Side B Side A Side B Side A Side BTriangle mark
33.9 Coil Coil Coil Coil Coil Coil Coil Coil Coil Coil Indicated position
L 35 10 25 23
7 5 3 1 Note)
Connector
Air gripper
26 24
8 6 4 2
Cable length (L) Part no.
300mm V100-49-1-1
) ( ) Side A Coil
) ( ) Side B Coil
( ) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Side A Coil
) ( ) Side B Coil
) ( ) Common
) ( ) Common
500mm V100-49-1-2
1000mm V100-49-1-3
2000mm V100-49-1-4 + +
Directional control
+ + + + + + + + + +
5000mm V100-49-1-7
-
-
{((
-
-
-
-
-
-
-
-
-
-
{ ((
{(
{ ((
{ ((
{ ((
Connected
valve
on the
22 33.9 board Station 12 Station 4 Station 3 Station 2 Station 1
1
Triangle mark 2
(Max. 12 stations)
3
24
25
Reference figure 26
Note)
14
Flow control
equipment
Terminal no. is not indicated on the connector. The terminal no.
indicated in the connection schematic of connector, as shown in
the reference, means a correlation of 1, 2, 3···26 from the triangle
mark side on the flat ribbon cable of connector.
Flat ribbon cable manifold
· For more than 10 stations, both poles of the common should be
control equipment
Caution wired.
Filter, Pressure
· For single solenoid, connect to the solenoid B side.
Type 21P Type 32P · The maximum number of stations that can be accommodated is
12. Please contact SMC for more stations.
· Only non-polar valves are available for the DC flat ribbon cable
manifold, therefore negative COM or positive COM wiring of the
manifold is possible. The valve dose not switch with negative
Bracket
• In the manifold valves, the wiring to the individual valves is
provided on a printed circuit board, and the connection to the
external wires is consolidated through the use of a flat cable.
Caution
For 10-SYJ3000 (Single) or 10-SYJ7000 with bracket, do not use
•A single MIL flat cable connects the entire manifold to your
Air preparation
it without bracket.
equipment
Caution
Pressure switch
10-SYJ7000 M3 0.8N·m
563
Series 10-SYJ3000/5000/7000
Specific Product Precautions 7
Be sure to read before handling.
Caution
Pilot valves in this series are improved to provide excellent
energy saving results. However, following this improvement,
these new valves are no longer compatible with the conventional
pilot valve used at the interface. Please consult with SMC when
you need to exchange these pilot valves, in the case of manual
override (marked in orange) of the adapter plate.
New type
Manual override
(Blue)
-+
B
A
Interface
Pilot valve
(10-V111) Adapter plate
Conventional type
Manual override
(Orange)
-+
B
A
Interface
Pilot valve
(10-SY114) Adapter plate
564