DME CONTROL SYSTEMS

104 Control Systems

Table of Contents

TSP and TSP Plus Temperature


Control System.........................................105-110
Touch Screen Panel, Powerful, flexible and affordable

Smart Series® Temperature


Control Systems...................................111 to 155
RoHS/WEEE-compliant temperature
controls for hot runner systems

Valve Gate Controls.................................156-162


Energy efficient, reliable and compact
hydraulic and pneumatic controls

Technical Support...................................163-164
Customer power requirement worksheet
Breaker wattage size table
Control system repairs and returns

Online Price Guide Go to www.dme.net/prices for the latest pricing guide.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smar t Series ® TSP ™
Temperature C ontrol System
Series

POWERFUL, FLEXIBLE
AND AFFORDABLE
106 TSP Temperature Control System

TSP Features and Benefits

The TSP™ Temperature Control System optimizes injection molding performance of any hot runner
system with the advanced features of a touch screen unit but within a minimal footprint.

Benefits
TSP user-friendly performance
■ Intuitive, leading edge touch screen display with adjustable viewing angle
■ Automatically employed diagnostics to ensure optimal hardware configuration
and performance
■ Advanced micro controller technology
TSP Features and Benefits

■ Continuous ground fault and current measurement

Plug-and-play system architecture


■ Patented “all-in-one” control card designed for reliability
■ Modular 6-zone cards; 15 amps per zone
■ Field calibration mode
■ Universal power supply
|
TSP Temperature Control System

Optimizes performance for all hot runner systems


■ Unique low voltage soft-start feature maximizes heater life
■ Uniform startup feature reduces scrap and energy usage
■ Proprietary adaptive auto-tuning control algorithm
■ Phase angle or burst firing modes (time proportional, zero-crossing)

Robust, high-quality design


■ Compact solid metal enclosure with heavy-duty industrial connectors
■ Mold and controller protection features
■ On-board heater and thermocouple fuses
■ Portable stand available

Optional 7" display with advanced feature set now available!

IMPORTANT NOTICE: TSP Controllers are not designed to control all zones as manifold zones.
Doing so will cause the main circuit breaker to trip.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


text
TSP Temperature Control System 107

TSP Specifications

Specifications Certification
available

TSP™ TEMPERATURE CONTROL SYSTEM SPECIFICATIONS


User Interface Full-color LCD touch screen on all HMI models
Display Size 5.7" QVGA
Calibration Accuracy 0.5˚C / 1˚F
Control Accuracy +/- 0.5˚C / 1˚F
Power Response Time 8.3 ms at 60 Hz
Control Algorithm Adaptive PID 2 with auto-tuning

TSP Temperature Control System


Degree (F or C) Software selectable
Thermocouple J- or K-Type, software selectable
Operating Range 0 - 472˚C or 32 - 882˚F
Output Voltage Maximum 264 VAC
Supply Voltage 200/240 Delta or 380/440V 3Ø Star
40A 3-phase breaker for 6- and 12-zone control units
Supply Breaker
63A 3-phase breaker for 18- to 48-zone control units
Frequency 50 - 60 Hz automatic switching
Ambient Temperature Range 5 - 45˚C (41 - 113˚F)
Humidity Range Up to 95% non-condensing
Ground Fault Detection 40mA per zone
Power Control Phase angle or burst firing modes (time proportional, zero-crossing)
Overload Protection Semi-conductor fuses on both heater legs
Control Modes Closed loop (auto), open loop (manual), standby, boost mode and slave mode

|
TSP Specifications
Alarm Output Closing contact relay, max. 5A, 230V
T/C and Power Connector HAN 24e or 3
LED Indicators Fault, Scan
Soft-Start with Auto-Tune Unique low voltage method for heater safety
Input Protection Plug-in nano fuses on both TC legs
Port (optional) USB

ITEM NUMBER SLOTS # OF ZONES AVAILABILITY


ITS-06-15 1 6 Special order; contact DME
ITS-12-15 2 12 In stock
ITS-18-15 3 18 Special order; contact DME
ITS-24-15 4 24 In stock
ITS-30-15 5 30 Special order; contact DME
ITS-36-15 6 36 Special order; contact DME
ITS-42-15 7 42 Special order; contact DME
ITS-48-15 8 48 In stock

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


text
108 TSP Temperature
textControl System

TSP Component Ordering Information

Mold Power Cables (15 AMP Max)


ITEM ITEM ITEM NUMBER FROM 15 AMP TO POWER INPUT
MPC12C10G NUMBER NUMBER NUMBER OF ZONES FRAME (S) CONNECTOR
(MAX.)
10 FOOT LONG 20 FOOT LONG 30 FOOT LONG FOR CONNECTIONS
MPC12C10G MPC12C20G MPC12C30G 12 12 ZONE PIC12G
TO FRAME TO MOLD

Thermocouple Cables (for 15 or 30 AMP Mainframes)


ITEM ITEM ITEM NUMBER FROM 15 AMP TO THERMOCOUPLE
TC12C10G NUMBER NUMBER NUMBER OF ZONES FRAME (S) CONNECTOR
(MAX.)
10 FOOT LONG 20 FOOT LONG 30 FOOT LONG FOR CONNECTIONS
TC12C10G TC12C20G TC12C30G 12 12 ZONE MTC12G
Ordering Information

TO FRAME TO MOLD

ZONES Controller Cables Terminal Mounting Box

MPC12C10G

12 ZONES
OF CONTROL
+ (1 each)
+ PTC12TBts (1 each)
| TSP |Component

(15 AMP)
blank

TC12C10G
ITS-12-15
Systems

MPC12C10G

24 ZONES
+ +
System

OF CONTROL (2 each) PTC12TBts (2 each)


Control

(15 AMP)

ITS-24-15 TC12C10G
TSP Temperature Control

MPC12C10G

48 ZONES
OF CONTROL
(15 AMP)
+ (4 each) + PTC12TBts (4 each)

TC12C10G
ITS-48-15

Module Replacement Fuses


(sold in packs of 5)
RPM0124

ITEM ITEM NUMBER DESCRIPTION AMPS


ITSTROLLEY RPM0123 POWER FUSE 15
RPM0124 TC FUSE .062

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


109
TSP Temperature Control System Series

TSP Plus Temperature Control System

Everything you loved about the original TSP controller with new enhanced features
for optimal control.
• Automatic Leak detection
• Enhanced 7” Color Touch screen
• Storage : up to 100 Tools
• Full IO function card with 4 input + 4 output for communication
• Optional Thermocouple to monitor steel temperature and alarm if cooling is off
• Accuracy 0.01 oF
• Ability to control Small Mass / High Watt density nozzles
• Field selectable PID (parameters) to optimize control process
• APS technology (Adaptive Process System)
• SPI communication Protocol via RS232/RS485 included

ITEM NUMBER SLOTS # OF ZONES


ITSP-12-15 2 12
ITSP-24-15 4 24

TSP Temperature Control System


ITSP-48-15 8 48

Custom zone configurations available upon request

ITEM NUMBER Description


PCB replacement card, 6
ITSCGR-A
zones @ 15 AMP
See reverse side for accessories 7”
Smart Series user-friendly performance Optimizes performance for all hot
• Intuitive, leading edge touch screen display with adjustable runner systems
viewing angle • Unique low voltage soft-start feature maximizes

|
heater life

TSP Plus
• Automatically employed diagnostics to ensure optimal
hardware configuration and performance • Uniform startup feature reduces scrap and energy
• Advanced micro controller technology usage
• Continuous ground fault and current measurement • Proprietary adaptive auto-tuning control algorithm
• Phase angle or burst firing modes (time
proportional, zero-crossing)
Plug-and-play system architecture
• Patented “all-in-one” control card designed for reliability
Robust, high-quality design
• Modular 6-zone cards; 15 amps per zone
• Compact solid metal enclosure with heavy-duty
• Field calibration mode industrial connectors
• Universal power supply • Mold and controller protection features
• On-board heater and thermocouple fuses
• Portable stand available
IMPORTANT NOTICE: Smart Series Controllers are not designed to control all zones as manifold zones.
Doing so will cause the main circuit breaker to trip. Certification
available

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


text
110 TSP Temperature
textControl System

TSP Plus Component Ordering Information

Mold Power Cables (15 AMP Max)


ITEM ITEM ITEM NUMBER FROM 15 AMP TO POWER INPUT
MPC12C10G NUMBER NUMBER NUMBER OF ZONES FRAME (S) CONNECTOR
(MAX.)
10 FOOT LONG 20 FOOT LONG 30 FOOT LONG FOR CONNECTIONS
MPC12C10G MPC12C20G MPC12C30G 12 12 ZONE PIC12G

TO FRAME TO MOLD

Thermocouple Cables (for 15 or 30 AMP Mainframes)


ITEM ITEM ITEM NUMBER FROM 15 AMP TO THERMOCOUPLE
TC12C10G NUMBER NUMBER NUMBER OF ZONES FRAME (S) CONNECTOR
(MAX.)
10 FOOT LONG 20 FOOT LONG 30 FOOT LONG FOR CONNECTIONS
TC12C10G TC12C20G TC12C30G 12 12 ZONE MTC12G
TO FRAME TO MOLD

ZONES Controller Cables Terminal Mounting Box

MPC12C10G
| blank| TSP Plus

12 ZONES
OF CONTROL
(15 AMP) + (1 each)
+ PTC12TBts (1 each)

TC12C10G
Control System

ITSP-12-15
Control Systems

MPC12C10G
24 ZONES
OF CONTROL
(15 AMP) + (2 each) + PTC12TBts (2 each)
TSP Temperature

TC12C10G
ITSP-24-15

MPC12C10G
48 ZONES
OF CONTROL
(15 AMP)
+ (4 each) + PTC12TBts (4 each)

TC12C10G
ITSP-48-15

ITEM ITEM
ITSPTROLLEY ITSPALRMLT
Module Replacement Fuses
(sold in packs of 5)

RPM0124
ITEM NUMBER DESCRIPTION AMPS
RPM0123 POWER FUSE 15
RPM0124 TC FUSE .062

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smar t Series ®

rohs/weee-compliant
temperature controls
for hot runner systems
112 Smart Series®
RoHS/WEEE Compliant
Advanced Temperature Control for Hot Runner Systems

Capability/RoHS and WEEE Compliant


DME offers 2-, 5-, 8-, and 12-zone standard mainframes for 15A operation and 1-, 2-, 3-, and
5-zone standard mainframes for 30A operation. Components listed in this catalog satisfy all
international compliances. This includes RoHS (Restriction of Hazardous Substances) that
prohibits or restricts the use of six potentially harmful materials in electronic equipment, and
WEEE (Waste Electrical and Electronic Equipment) that requires equipment made after August
2005 to be taken back and recycled by the manufacturer, rather than just “thrown away.”

Two-Year Warranty
All DME temperature controllers are now covered by a two-year warranty, excluding fuses and
triacs.
Advanced Temperature Control for Hot Runner Systems

Electrical Noise Immunity


To enhance immunity from electrical noise, power and thermocouple wire are harnessed
in separate wire ways within the body of the frame. Additional noise immunity is provided
through the use of shielded thermocouple wires.

The DME Smart Series® is the result of intensive and dedicated research with a goal of
designing today’s most versatile and reliable line of temperature controllers. DME achieved
this goal by not only incorporating the latest technology, but by also making certain that each
controller is easy to install and above all…easy to operate.

Heavy Duty Welded Construction


With years of experience behind its design, the Smart Series line is built to last under the
most rigorous conditions. The mainframe’s welded 16 gauge steel construction ensures long
life and peak performance. Cooling fans in the frame are strategically located to increase air
ventilation, maintain cooler running conditions, and promote control module reliability.
|
Smart Series®

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 113

CE COMPLIANT! DME Mainframes and Modules comply with


Electromagnetic compatibility and low voltage directives

Control Modules
SSM (15 and 30 AMP): The SSM module provides accurate temperature control, including Smart Start®
heater dry out circuitry, thermocouple fault displays and auto/manual modes of operation. The SSM
features automatic or manual bumpless transfer which, in the event of a thermocouple fault, provides
switch over to manual mode at the proper power setting to continue molding until the fault can be
corrected. This module can also trigger remote standby heat (idle), boost, off, and alarm functions when
used with the TAS module.

DSS (15 and 30 AMP): For those who require independent dual displays for process and setpoint
temperatures, the DSS is the ideal choice. The DSS module also features automatic or manual bumpless
transfer. This module is also fully compatible with the TAS module for standby heat and alarm functions.

Accessory Modules
TAS: The TAS module provides over/under visual and audible alarms, boost, and standby heat control
with control modules as stated above. The TAS module can accommodate up to 63 zones of control.
SSM1512 Alarm is activated at ± 30° F. See pages 143-144 for details.
NOTE: The TAS accessory module requires the use of “MFC” style communications mainframes.

Smart Series®
Non-communications frames may be upgraded on-site with installable kits.

|
CE COMPLIANT! Control Modules
Simplified Power Hook-Up
Concern for user convenience didn’t stop with improved operation features. DME
went one step beyond
DSS1512 to ensure that the power hook-up procedure goes smoothly as well. For this reason,
detailed schematics
for various hook-ups are provided directly on all mainframe back panels. If it is ever
necessary to change
the configuration, these diagrams will help ensure safe and proper connections. All
wiring diagrams can
be referenced at the end of this section.

SSH Controller (10 AMP)


The SSH is a stand-alone single zone controller ideal
for use with hot sprue bushings or machine nozzles.
SSH1022

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


114 Smart Series®

Smart Series® Temperature Control Systems

1 Mainframe

2 Circuit Breaker/Disconnect
3 Mold Power Cable

4 Thermocouple Cable
5 Mold Power Input Connector
6 Insulated Crimp Connector
7 Thermocouple Connector
8 Terminal Mounting Boxes
9 Mainframe Blank Panels
10 Module Replacement Fuses
TABLE OF CONTENTS PAGE
Smart Series® Temperature Control Systems

11 Control Modules
Introduction................................................................................................................................. 112-113
Typical System Configurations........................................................................................................115
SSH Single Zone Controller...................................................................................................... 116-117
Single and Two-Zone Mainframes and Accessories........................................................... 118-121
Single Zone High Power Mainframes.............................................................................................121
Smart Series Mainframes......................................................................................................... 122-124
Digital Current / Voltage Monitor....................................................................................................125
Smart Series Accessories................................................................................................................126
Standard Mainframe Connector Wiring.........................................................................................127
Wiring Diagram for Hot Runner Molding System
and Smart Series / G-Series Mold Connectors..........................................................................128
Wiring Diagram for Hot Runner Molding System
and High Power Smart Series / G-Series Mold Connectors....................................................129
|
Smart Series®

Cables and Connector Kits....................................................................................................... 131-132


Mold Connector Pocket Layouts............................................................................................. 133-134
Terminal Mounting Boxes......................................................................................................... 135-136
SSM Temperature Control Modules....................................................................................... 137-138
DSS Temperature Control Modules........................................................................................ 139-140
TSM Temperature Control Module with Color Touch Screen............................................ 141-142
TAS Temperature Alarm / Standby Heat Modules............................................................... 143-144
Replacement Parts and Service Items................................................................................... 145-147
Input Power Wiring Diagrams................................................................................................. 148-150
Alternate Cable Configuration................................................................................................. 151-153
Terminal Box Detail & Mold Connectors – European..................................................................154

Cable Storage Basket.......................................................................................................................155

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 115

Typical System Configurations


SSM1512
DSS1512 5 Zones of control (15 amp)

+ + MPC5C10G + PTC5TBts +
MFP5G
MFS512G
X5 TC5C10G

SSM1512
DSS1512
8 Zones of control (15 amp)

+ + MPC8C10G
+ PTC8TBts +
MFP8G
MFS512G
X8 TC8C10G

Smart Series®
SSM1512
DSS1512
12 Zones of control (15 amp)

+ + MPC12C10G
+ PTC12TBts
+

|
Typical System Configurations
MFP12G
TC12C10G MFS512G
X12
SSM3012
DSS3012
2 or 3 Zones of High Power control (30 amp)
MTC5G

+ + MPCH23C10G + + +
MFHP2G
MFHP3G
PTCH23TBG
MFS512G
TC5C10G PICH23G
X2 or 3X
SSM3012
DSS3012
5 Zones of High Power control (30 amp)
MTC5G

+ + mpch5c10g
+ + +
MFHP5G
PTCH5TBG
MFS512G
X5 TC5C10G PICH5G

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


116 Smart Series®
RoHS/WEEE Compliant
Smart Series Single Zone Temperature Controller
®

SSH1022/21 (10 AMP)


• Compact
• Easy-to-use
• Includes new, improved and unique features
• Provides microprocessor- based PID control
• More accurate than analog or variac controllers
• Built-in thermocouple diagnostics
• Ideal for use with a hot sprue bushing
or a machine nozzle

Key Features Operational Refinements


• Large Digital Display • Improved SmartStart®
Smart Series Single Zone Temperature Controller

- For easier readability of temperature, % power and faults - A more gradual temperature rise leads to a more effective
• Setpoint Pushwheel heater dry out period,
- For setting desired setpoint temperature thereby extending heater life
- Allows adjustment of setpoint before turning power on - SmartStart® now available as an option in manual mode
• AUTO % Power Display • SelectiveCycle®
- Shows % power output while in AUTO mode - A very high speed power output approach
- Indicates average % power requirement on thermocouple - Enables accurate temperature control and longer heater life
failure • Bumpless Transfer
- A diagnostic tool for solving problems - When a thermocouple failure occurs, operation is automatically
continued with a learned % power
Switchable Options - Unique software accurately assigns percent power setting
• Shorted Thermocouple Sensitivity Adjustment • Third Fuse
- Operation can be tailored to fast or slow reaction times - Allows for display of low temperature alarm when the load
- Sensitivity can be adjusted with internal switches fuses are blown
- Very useful for zones with long startup times
• Switchable °C/°F Operation
- Scale indicated at startup
• K Type Thermocouple Support Power
STandby booST
|

off
• Cut Feature heaT
Smart Series®

- Gain cut feature for small nozzles and heaters with


ungrounded internal thermocouples

Front Panel Digital LED Indicators

baCKward ShorTed oPen bumPleSS fronT Panel TemP mode TemP mode ProCeSS manual loCKouT
ThermoCouPle ThermoCouPle ThermoCouPle TranSfer loCKouT fahrenheiT CenTigrade TemP % Power error

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 117
RoHS/WEEE Compliant
Smart Series Single Zone Temperature Controller
®

SSH1022/21 (10 AMP)


Controller includes 19-foot power cord, mating mold power and thermocouple connector
(CKPTM1) and two spare fuses (ABC10). Additional cables and/or connectors must be
controller VOLTS ordered separately. See Page 121 for detailed information on cables and connectors.
Item NUMBER (vac) Warranty: Two year (excluding triac and fuses).
SSH1022 240 4
SSH1021 120
6

cABLE* LENGTH
Item NUMBER (FEET)
MPTC10 10
MPTC20 20
See page 119

Smart Series®
CKPTM1 1 2 3
INCLUDED 5

Front Panel Controls and Indicators

|
1. Process Temperature Display:

Smart Series Single Zone Temperature Controller


Shows process temperature, thermocouple faults and other operational modes.
MOLD POWER AND Displays % power when switch (3) is pressed down.
THERMOCOUPLE CONNECTOR* 2. Temperature Deviation Lights:
Item NUMBER Indicates deviation from setpoint. Outer lights blink at more than ±40˚F (22˚C)
from setpoint.
CKPTIC1
3. Auto / Manual / % Auto Power Switch:
See page 119 Selects AUTO or MANUAL control mode. shows % power when pressed into
“% AUTO” position.
4. LED Mode Indicators:
Left LED illuminates during manual mode. Right LED illuminates when power
is supplied to heater. Right LED blinks during SmartStart®.
5. Setpoint Pushwheel:
Three digit switch programs setpoint in AUTO mode. Right two digits program
% power in MANUAL mode.
6. Power On/Off Switch:
* Items ordered Controls AC power to module.
separately

Rear Panel
3 1. Mold Power and Thermocouple Output Connector:
CKPTIC1 connects to the heater and thermocouple. Mating connector
CKPTM1 is supplied with controller.

2. Power Input Cord:


Nineteen foot cord supplies power to controller. Plug supplied with
SSH1021 (120 VAC) units. No plug supplied with SSH1022.
1 2
3. Load Fuse Receptacles:
Provides safe and easy replacement of load fuses.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


118 Smart Series®
RoHS/WEEE Compliant
Smart Series Single and 2-Zone Mainframes (10 AMP max.)
®

Single and Two-Zone 10 AMP Mainframes


The DME Portable 10 AMP Mainframes are designed for use with 10 or 15 AMP*
Smart Series or G-Series Temperature Control Modules. Mainframe is supplied with
power input and power-thermocouple output connectors. Circuit breaker provides
safety for operation. Control modules and cables are to be ordered separately.
NOTE: Maximum safe operating amperage is 10 AMPS per zone when using
15 AMP modules. If application will draw more than 10 AMPS per zone,
use 15 AMP Mainframe (MFFPR2G).
A MFP1G
*User must install ABC10 (10 AMP) fuses in the 15 AMP control modules to protect the mainframe.
MFP1G1
Single and Two-Zone 10 AMP Mainframes
B
(50-60 Hz, single phase)
A: AC2024F (Power to Mainframe);
item watts connectors
AC1512F supplied with MFP1G1 ZONES volts
numberS ** per zone
WATTS supplied
CONNECTORS
B: CKPTM1 (Connector to heater) ZONES ITEM NUMBERS** VOLTS
Smart Series Single and 2-Zone Mainframes

PER ZONE SUPPLIED


(1) AC1512F (POWER IN)
1 mfp1g1 120 1200 (1) AC1512F (POWER IN)
This single-zone controller is ideal for 1 MFP1G1 120 1200 (1) CKPTM1 (POWER-T/C OUT)
(1) CKPTM1 (POWER-T/C OUT)
use with Straight-Shot and Gate-Mate (1) AC2024F (POWER IN)
hot sprue bushings. 1
1 MFP1G 240
240 2400
2400 (1) AC2024F (POWER IN)
MFP1G (1) CKPTM1
(1) CKPTM1 (POWER-T/C
(POWER-T/C OUT) OUT)
(1) AC2024F
(1) AC2024F (POWER
(POWER IN) IN)
2 2 MFPR2G
MFPR2G 240 240 2400 2400
(1) CKPTM1
(2) CKPTM1 (POWER-T/C
(POWER-T/C OUT) OUT)

**Includes frame and connectors listed. Modules and cables ordered separately.
NOTE: Replacement power connectors in frame are also available on special order.

Recommended Mold Pocket Layout


(For Mold Power-Thermocouple Input Connector CKPTIC1)

MFPR2G
A
|
Smart Series®

A: AC2024F (Power to Mainframe)


B: CKPTM1 (Connector to heater)

Single zone, horizontal


10 amp controllers
(SSH1022/21) also
available. See page 116

DIMENSIONS
(all frames)
7"W x 9"H x 10"D
(9"H dimension does not
include connectors or handle)

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 119

RoHS/WEEE Compliant: Smart Series® Single and


2-Zone Mainframe Accessories (10 AMP)
For Use With MFP1G, MfP1G1, MFPR2G, SSH1022 and SSH1021
Mold Power-thermocouple Input Connector
Item A single-Zone Power-Thermocouple Input Connector is available for mounting in or on
NUMBER the mold to accept the power-thermocouple cable from the mainframe. Water resistant,
CKPTIC1 the connector has an integral retaining latch for a secure cable connection and numbered
screw-type terminals for power and thermocouple lead wires.
*Can be mounted on top of mold for use with hot sprue bushings.

Armored Mold Power-thermocouple Cables


Item
NUMBER Single-Zone Mold Power-Thermocouple Cables are constructed of special lead wire for
MPTC10 use in high temperature environments, and are available to connect the mainframe to the
connector on the mold. Available in lengths of 10 or 20 feet. Integral retaining latches

Smart Series®
MPTC20
on the mainframe and mold connections provide secure cable connections. Connector
configurations ensure proper insertion of cable.

Replacement Connector Kits (for Controller & Cables)


Male Power – T/C Connectors: FEMALE POWER – T/C CONNECTORS:

|
 CKPTM1 is on MPTC10/20 Cables; CKPTF1 is on MPTC10/20 Cables;

Smart Series Single and 2-Zone Mainframe Accessories


Power Input Connectors Mates with Frame or CKPTF1L only Mates with Mold or CKPTM1L only
For Mainframe  CKPTM1L Mates With CKPTF1 only  CKPTF1L Mates with CKPTM1 only

MALE
CKPTF1 5 4
AC1512F CKPTM1 1

3 for CKPTIC1
2
+ - and CKPTM1
or CKPTM1L
W
PTC210
AC2024F CKPTM1L CKPTF1L B

Item Item Item


VOLTS Item FEMALE
NUMBER NUMBER NUMBER
NUMBER 5 1
AC1512F 120 CKPTM1 CKPTF1
PTC210 4
AC2024F 240 CKPTM1L CKPTF1L 2
3 for CKPTOC1
- + and CKPTF1
Power-Thermocouple Output Terminal Mounting or CKPTF1L
B
Connector (for Mainframe Bulkhead) Boxes – Prewired
(10 AMP) 5 Pin W
Item
NUMBER Terminal Mounting Boxes provide the easiest and most
CKPTOC1 economical method of mounting power and thermocouple
connectors on the mold. Constructed of plated heavy gauge
steel, each box is precut and drilled for quick mounting of
Item NUMBER
the box to the mold (2-zone, prewired terminal mounting
PTC210TBGTS box with terminal strip shown with cover plate removed).

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


120 Smart Series®

Smart Series® 2-Zone Mainframes (15 AMP) and Accessories

Two-Zone 15 AMP Mainframes


MFFPR2G Provides 15 AMP (3600 watts) per zone. For use with Smart Series or G-Series modules.
Supplied with built-in cooling fan, power input, power output and thermocouple input
connectors. Control modules and cables are ordered separately.
TWO-ZONE 15 AMP MAINFRAME (240 VAC, 50-60 Hz, SINGLE PHASE)
item number watts per zone connectors supplied
(1) AC1240F (POWER IN)
MFFPR2G 3500 (1) AC1524M (POWER OUT)
(2) M2MJ (T/C IN)
Includes frame and connectors listed. Modules and cables ordered separately.
NOTE: Replacement parts in frame are also available by special order.
See pages 146-147.
AC1240F
M2MJ item numberS DESCRIPTION
AC1524M
Smart Series 2-Zone Mainframes and Accessories

Female 240 VAC twist-lock power input connector


AC1240F*
(mates with male frame power input)
Male 240 VAC power output connector
AC1524M*
(mates with female frame power outputs)
Thermocouple mini-plug
M2MJ*
FRAME DIMENSIONS: (mates with frame jack strip connector)
7"W x 9"H x 10"D 2 zone, pre-wired terminal mounting box with terminal strip
PTC2TBGTS
(9"H dimension does not (mounts to mold; mates with PTC0110 or PTC0129 cables)
include connectors or handle) * Included with MFFPR2G

Armored Mold Power –


Thermocouple Cables (15 AMP)
Single-Zone Mold Power-Thermocouple Cable is
constructed of special lead wire for use in high
temperature environments. This cable connects
Item NUMBER the mainframe to the connector on the mold.
|

Available in lengths of 10 or 20 feet. Retaining


Smart Series®

PTC0110
latches on the mold connector provide secure
PTC0120 cable connections.
For use with MFFPR2G only

Terminal Mounting Boxes –


Prewired (15 AMP)
Terminal Mounting Boxes provide the easiest and
most economical method of mounting power and
thermocouple connectors on the mold. Constructed
of plated heavy gauge steel, each box is precut and
drilled for quick mounting of the box to the mold
item number (2-zone, prewired terminal mounting box with
PTC2TBGTS terminal strip shown with cover plate removed).

For use with MFFPR2G only NOTE: 6-pin connectors and pins are available as a special order only. These are crimp
contacts. (See pages 148-149 for mounting dimensions.)

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 121

Smart Series® Single Zone


High Power Mainframes (30 AMP Max.)
MFHP1G The DME Portable Single-Zone High Power Mainframe is designed for use with 30 AMP
Smart Series or G-Series temperature control modules. Mainframe is supplied with built-in
cooling fan, power input, power output, and thermocouple input connectors. Circuit breaker
provides safety for the operator. Control modules and cable are ordered separately.
Single Zone 30 AMP Mainframes (240 VAC, 50-60 Hz, Single Phase)

Replacement Connectors and Accessories

M2MJ

AC1240F

Smart Series®
AC1240M

FRAME DIMENSIONS:
7"W x 9"H x 10"D
(9"H dimension does not
include connectors or handle)

|
Smart Series Single Zone High Power Mainframes
D E
*Included with MFHP1G mainframe

NOTE: Overall dimensions


shown include allowances
for hardware (assembly
screws) but not connectors

TERMINAL MOUNTING BOX


PTCH1TBG
(Connectors shown are
ordered separately)
D: TCS1
E: AC1240MI

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


122 Smart Series®

Smart Series® Mainframes (15 AMP)

WIDTH (W)
Smart Series® Mainframe (15 AMP Max.)
Configurations
The 12 configurations illustrated below provide a wide selection of zone capacities
Main AC power
to suit most control applications. The 5-, 8- and 12-zone frames (MFP5, 8, and 12G)
Cooling Fan
input strain relief use individual frame sections. The 16 thru 48 zone frames use 2, 3, or 4 frame sections
rigidly fastened together into one prewired integral unit which requires only one main
AC power input connection. The Current Voltage monitor option will be factory installed
when ordered at same time as Mainframe. Control modules, cables, mold connectors
and other accessories are ordered separately (see table on next page).

 Each frame section


Thermocouple
input with (MFP5G, MFP8G,
retaining
latch and MFP12G) has
Power output its own cooling fan.
9"
with retaining
latch  Multi-section frame
heights are multiples
12" of 9" height shown
(e.g. MFP32G is
Smart Series® Mainframes

Worldwide Wiring 27" high).


Capabilities 
Unless otherwise specified, all Main AC input
Smart Series Mainframes will be shown will always
supplied to accept 240 VAC, 3 phase, be in bottom frame
4-wire, 50-60 Hz input power. Wiring
section. For higher
diagram (included on the access cover)
illustrates the variety of other voltage, power requirements,
phase and load balancing arrangements individual power
possible, such as: (380-415V, 3 phase, inputs and circuit
5-wire, 50-60 Hz), (208-240V, single
breakers can be
|

phase, 3-wire, 50-60 Hz) and (110-120V,


Smart Series®

single phase, 3-wire, 50-60 Hz). factory installed in


These wiring adjustments can be each section of a
performed in the field to suit the stack frame on a
requirements of the application.
If specified at the time of original special order basis.
order, DME will supply the
Mainframe required.
MOLD POWER CABLE (10, 20 OR 30 FOOT)
ITEM NUMBER W*
THERMOCOUPLE CABLE (10, 20 OR 30 FOOT)
MFP5G 14 3/16
MFP8G 20 3/16
MFP12G 28 3/16
* Dimension does not include
connectors
NOTE: Combination frames to
accommodate both 15 and
30 AMP modules (with or
without communications)
are available by special order.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 123

Smart Series® Mainframes (15 AMP)

SMART SERIES MAINFRAMES


CABLES AND MOLD CONNECTORS REQUIRED
Optional Current Voltage Monitor
(Not included with Mainframes and Must be Ordered Separately)
is Factory Installed in CV-Style Frames
Z “MFP” TYPE FOR “MFP” TYPE WITH “MFCP” TYPE FOR “MFCP” TYPE WITH MOLD POWER CABLES THERMOCOUPLE CABLES MOLD POWER INPUT
THERMOCOUPLE
O TEMP. AND CURRENT VOLTAGE TEMP. CONTROL AND CURRENT VOLTAGE C10=10 FT. C20=20 FT. C30=30 FT. C10=10 FT. C20=20 FT. C30=30 FT. CONNECTORS (INCL.
CONNECTORS
N POWER CONTROL MONITOR COMMUNICATIONS MONITOR (SELECT LENGTH DESIRED) (SELECT LENGTH DESIRED) CRIMP CONNECTORS)
E ITEM ITEM NUMBER ITEM ITEM NUMBER ITEM ITEM ITEM ITEM
S QTY. QTY. QTY. QTY.
NUMBER (CV-STYLE) NUMBER (CV-STYLE) NUMBER NUMBER NUMBER NUMBER
5 MFP5G MFP5GCV MFCP5G MFCP5GCV 1 MPC5C10G, C20G or C30G 1 TC5C10G, C20G or C30G 1 PIC5G 1 MTC5G
8 MFP8G MFP8GCV MFCP8G MFCP8GCV 1 MPC8C10G, C20G or C30G 1 TC8C10G, C20G or C30G 1 PIC8G 1 MTC8G
12 MFP12G MFP12GCV MFCP12G MFCP12GCV 1 MPC12C10G, C20G or C30G 1 TC12C10G, C20G or C30G 1 PIC12G 1 MTC12G
16 MFP16G MFP16GCV MFCP16G MFCP16GCV 2 MPC8C10G, C20G or C30G 2 TC8C10G, C20G or C30G 2 PIC8G 2 MTC8G

1 MPC8C10G, C20G or C30G 1 TC8C10G, C20G or C30G 1 PIC8G 1 MTC8G


20 MFP20G MFP20GCV MFCP20G MFCP20GCV and and and and
1 MPC12C10G, C20G or C30G 1 TC12C10G, C20G or C30G 1 PIC12G 1 MTC12G

24 MFP24G MFP24GCV MFCP24G MFCP24GCV 2 MPC12C10G, C20G or C30G 2 TC12C10G, C20G or C30G 2 PIC12G 2 MTC12G

2 MPC8C10G, C20G or C30G 2 TC8C10G, C20G or C30G 2 PIC8G 2 MTC8G


28 MFP28G MFP28GCV MFCP28G MFCP28GCV and and and and
1 MPC12C10G, C20G or C30G 1 TC12C10G, C20G or C30G 1 PIC12G 1 MTC12G

1 MPC8C10G, C20G or C30G 1 TC8C10G, C20G or C30G 1 PIC8G 1 MTC8G


32 MFP32G MFP32GCV MFCP32G MFCP32GCV and and and and

Smart Series®
2 MPC12C10G, C20G or C30G 2 TC12C10G, C20G or C30G 2 PIC12G 2 MTC12G

36 MFP36G MFP36GCV MFCP36G MFCP36GCV 3 MPC12C10G, C20G or C30G 3 TC12C10G, C20G or C30G 3 PIC12G 3 MTC12G

2 MPC8C10G, C20G or C30G 2 TC8C10G, C20G or C30G 2 PIC8G 2 MTC8G


40 MFP40G MFP40GCV MFCP40G MFCP40GCV and and and and
2 MPC12C10G, C20G or C30G 2 TC12C10G, C20G or C30G 2 PIC12G 2 MTC12G

1 MPC8C10G, C20G or C30G 1 TC8C10G, C20G or C30G 1 PIC8G 1 MTC8G


44 MFP44G MFP44GCV MFCP44G MFCP44GCV and and and

|
and
3 MPC12C10G, C20G or C30G 3 TC12C10G, C20G or C30G 3 PIC12G 3 MTC12G

Smart Series® Mainframes


48 MFP48G MFP48GCV MFCP48G MFCP48GCV 4 MPC12C10G, C20G or C30G 4 TC12C10G, C20G or C30G 4 PIC12G 4 MTC12G

NOTE: For details on cables and connectors, see pages 130-132.

Terminal Mounting Boxes


ORDER ITEMS A and B or C ORDER ITEMS A and B or C
Z Z
O (A) (B) (C) O (A) (B) (C)
N FOR POWER INPUT FOR THERMOCOUPLE CABLES COMBINATION N FOR POWER INPUT FOR THERMOCOUPLE CABLES COMBINATION
E CONNECTORS CONNECTORS POWER & TC E CONNECTORS CONNECTORS POWER & TC
S ITEM ITEM ITEM S ITEM ITEM ITEM
QTY. QTY. QTY. QTY. QTY. QTY.
NUMBER NUMBER NUMBER NUMBER NUMBER NUMBER
5 1 PIC512TBG 1 MTC5TBG 1 PTC5TBG 1 MTC8TBG 1 PTC8TBG
8 1 PIC512TBG 1 MTC8TBG 1 PTC8TBG 32 3 PIC512TBG and and
2 MTC12TBG 2 PTC12TBG
12 1 PIC512TBG 1 MTC12TBG 1 PTC12TBG
36 3 PIC512TBG 3 MTC12TBG 3 PTC12TBG
16 2 PIC512TBG 2 MTC8TBG 2 PTC8TBG
2 MTC8TBG 2 PTC8TBG
1 MTC8TBG 1 PTC8TBG 40 4 PIC512TBG and and
20 2 PIC512TBG and and 2 MTC12TBG 2 PTC12TBG
1 MTC12TBG 1 PTC12TBG
1 MTC8TBG 1 PTC8TBG
24 2 PIC512TBG 2 MTC12TBG 2 PTC12TBG
44 4 PIC512TBG and and
2 MTC8TBG 2 PTC8TBG 3 MTC12TBG 3 PTC12TBG
28 3 PIC512TBG and and
1 MTC12TBG 1 PTC12TBG 48 4 PIC512TBG 4 MTC12TBG 4 PTC12TBG

NOTES: Combination terminal mounting boxes are available with connectors prewired to terminal strips. See page 135 for details.
See page 136 for dimensional details. For below flush mounting of connectors, see mold pocket layouts on pages 133-134.
See page 125 for current voltage monitor.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


124 Smart Series®

Smart Series® High Power Mainframes (30 AMP)

50 AMP 3-PHASE
CIRCUIT BREAKER HIGH POWER MOLD POWER CABLE (10, 20 OR 30 FOOT)

THERMOCOUPLE CABLE (10, 20 OR 30 FOOT)


9" (USE 5-ZONE CABLE) HIGH POWER
MOLD POWER
THERMOCOUPLE CONNECTOR INPUT CONNECTOR
TERMINAL MOUNTING BOX (OPTIONAL)
(14 3/16" WIDE)
INSULATED
CRIMP
50 AMP 3-PHASE CONNECTORS
CIRCUIT BREAKER (INCLUDED WITH
MOLD POWER
MAINFRAME WITH CIRCUIT BREAKER
INPUT
DISCONNECT IS STANDARD; CURRENT
9" CONNECTOR)
VOLTAGE MONITOR IS OPTIONAL

The 3 configurations illustrated at left provide 2, 3 or 5-zones of 30 AMP control for


higher wattage heater applications. The Current Voltage monitor option will be factory
(20 3/16" WIDE)
installed when ordered at the same time as Mainframe. Control modules, cables, mold
connectors and other accessories are ordered separately.
Smart Series® High Power Mainframes

70 AMP 3-PHASE
CIRCUIT BREAKER SMART SERIES HIGH POWER MAINFRAMES
Optional Current Voltage Monitor is Factory Installed in CV-Style Frames
Z “MFHP” TYPE FOR “MFHP” TYPE WITH “MFCHP” TYPE FOR TEMP. “MFCHP” TYPE WITH CURRENT
9" O TEMP. CONTROL CURRENT VOLTAGE MONITOR CONTROL AND COMMUNICATIONS VOLTAGE MONITOR
N
E ITEM ITEM NUMBER ITEM ITEM NUMBER
S NUMBER (CV-STYLE) NUMBER (CV-STYLE)

(28 3/16" WIDE) 2 MFHP2G MFHP2GCV MFCHP2G MFCHP2GCV


3 MFHP3G MFHP3GCV MFCHP3G MFCHP3GCV
Dimensions above do 5 MFHP5G MFHP5GCV MFCHP5G MFCHP5GCV
not include connectors
all frames are 12" deep CABLES AND MOLD CONNECTORS REQUIRED
(Not included with Mainframes and Must be Ordered Separately)
NOTE: Blank panels cover Z MOLD POWER CABLES THERMOCOUPLE CABLES MOLD POWER INPUT
THERMOCOUPLE
O C10=10 FT. C20=20 FT. C30=30 FT. C10=10 FT. C20=20 FT. C30=30 FT. CONNECTORS
unused zones in frames N (SELECT LENGTH DESIRED) (SELECT LENGTH DESIRED) (INCL. CRIMP CONNECTORS)
CONNECTORS
|

(shaded panels above). For E ITEM ITEM ITEM ITEM


Smart Series®

communications (MFCHP) S QTY. NUMBER


QTY.
NUMBER
QTY.
NUMBER
QTY.
NUMBER
type frames, these 2 1 MPCH23C10G, C20G or C30G 1 TC5C10G, C20G or C30G 1 PICH23G 1 MTC5G
zones may be used for 3 1 MPCH23C10G, C20G or C30G 1 TC5C10G, C20G or C30G 1 PICH23G 1 MTC8G
communication modules. 5 1 MPCH5C10G, C20G or C30G 1 TC5C10G, C20G or C30G 1 PICH5G 1 MTC12G

NOTE: For details on cables and connectors, see pages 130-132.

Terminal Mounting Boxes


Z
ORDER ITEMS A and B or C
O (A) (B) (C)
N FOR POWER INPUT CONNECTORS FOR THERMOCOUPLE CABLES CONNECTORS COMBINATION POWER & TC
E
S QTY. ITEM ITEM ITEM
QTY. QTY.
NUMBER NUMBER NUMBER
NOTE: Combination frames
2 1 PICH23TBG 1 MTC5TBG 1 PTCH23TBG
to accommodate
3 1 PICH23TBG 1 MTC5TBG 1 PTCH23TBG
both 15 and 30 AMP
modules (with or without 4 1 PICH5TBG 1 MTC5TBG 1 PTCH5TBG

communications) are
NOTE: See page 135-136 for dimensional details. For below-flush mounting of connectors, see
available by special order.
mold pocket layouts on pages 133-134.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 125

Smart Series® Digital Current/Voltage Monitor

Streamlined Design For Improved Performance


The new Current/Voltage Monitor is simple to operate and features a large 3
easy-to-read digital display. Ease of operation has been enhanced by streamlining
4
the unit and eliminating unnecessary switches and controls. When setting the
selector switch to the desired zone number, the ‘Amps’ function is selected.
The meter will then display the amount of current being delivered by the selected
module. Input voltage to the system can be measured by rotating the selector 5
switch to one of the three ‘line voltage’ positions. This will set the meter in the
‘voltage’ function and display the voltage of the selected phase.

Current Supply To Each Zone


To monitor the current supply to each zone, simply set the rotary selector switch 2
to the desired module zone number. The “Amps” function is then automatically
selected and is indicated by the letter ’A’ just to the right of the numbers in the 1

Smart Series®
display window. The meter displays the current being delivered to the heater load
in amperes.

Input Voltage From Each Phase


Set the rotary selector to the desired phase voltage position. This automatically
selects the ‘volts’ function which is indicated when the letter ‘V’ appears to the

|
right of the numbers in the display window. The meter will display the line voltage

Smart Series® Digital Current/Voltage Monitor


of the selected phase.
1. CIRCUIT BREAKER/DISCONNECT – Applies or removes power to all modules
in the frame.
2. POWER ON LIGHT (amber) – Illuminates when CIRCUIT BREAKER is in the
ON position.
3. AMPS/VOLTS METER – Digital multi-scale meter provides accurate readings
of zone current (AMPS) or input voltage (VOLTS).
4. AMPS/VOLTS INDICATOR – Appears automatically when either AMPS or
VOLTS is selected.
5. SELECTOR SWITCH – Multi-position switch automatically selects zone
current or phase line voltage to be monitored. For systems with more than
12-zones, additional meter and selector switch panels are supplied.

Specifications
Voltmeter Range 190 to 290 VAC (for 240 volt systems)
90 to 145 VAC (for 120 volt systems) NOTE: The Digital Current/Voltage Monitor
is a factory installed option which
Voltmeter Accuracy ± 3% of reading, 50 to 60 Hz replaces the standard circuit
breaker/disconnect, and is supplied
Maximum Voltmeter Input 400 VAC
when “CV-style” mainframes
Input Voltage 240/120 VAC, 50 to 60 Hz are ordered.
Ammeter Range 0 to 2; 0 to 30; 0 to 40 amperes
Ammeter Accuracy ± 2% @ 0 to 100% Duty Cycle, 50-60 Hz See pages 123 and 124 for
appropriate mainframe
Maximum Ammeter Input 30 Amperes item numbers.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


126 Smart Series®

Smart Series® Accessories

Universal Floor Stand


3 SECTIONS Floor stand
The Universal Floor Stand will accommodate all 15 or 30 amp width adjusts
1 SECTIONS Mainframes from one to four sections high. Stand is made from for 8- and
heavy gauge steel and includes locking casters (400 lb. rating). 12- zone
2 SECTIONS All assembly and Mainframe mounting hardware is included. mainframes
Heavy duty floor stand available for larger systems (1000 lb. rating).
4 SECTIONS
46"
ITEM NUMBER RATING
MFS512G 400 LBS
MFS512GHD* 1000 LBS
* HD stand not shown. 28 1/4
Floor stand comes with plates for 5-zone frame mounting
25 3/4" on 8-zone “x” pattern

Step-Down Transformer Kits (from 480 VAC to 240 VAC)


Transformer Kits are pre-wired and include enclosed transformer (480 VAC input, 240 VAC output)
with adjustable transformer voltage taps, one 10-foot cable for AC power-in (no connector), one
6-foot cable for mainframe (AC input), one safety switch, two extra fuses, floor stand (MFS512G)
and all mounting brackets and hardware required. Shipped with instructions for easy assembly.
Smart Series® Accessories

Single section frames mount to front or rear of stand. Also Available:


ITEM NUMBER RATING 1. Transformer only
TK61AG 6 KVA
2. Transformer and cables only
TK91AG* 9 KVA
3. Transformers with other voltage
TK151AG* 15 KVA
or current capacities
TK301AG** 30 KVA
4. Isolation Transformers

Mainframe not included. Contact DME for details and prices.


Adapter plates for narrower frames available by special order.
* Comes with plates for mounting 8-zone on 12-zone “x” pattern
|

** Supplied with MFS512GHD for this transformer size or larger and transformers mounted flat.
Smart Series®

NOTE: Power capacity needed depends on total load of system


(i.e. number of zones and heater load per zone).

Mainframe Module Replacement Fuses Insulated Crimp Connectors


Blank Panels (sold in packages of 5) For connection of mold power input connector leads
Used. to cover unused to heater leads. (195˚F / 90˚C maximum temperature)
zones in mainframes.
Push-pull fasteners
included in panel.
MFBP10G covers ITEM NUMBER AMPS
one 15 amp zone; ABC1 1
MFBP30G covers ITEM NUMBER AMPS RATING
ABC15 15
one 30 amp zone (or HWCC1 (Bag of 30) 10-15 16-22 RED
ABC10 10
two 15 amp zones). HWCC3 (Bag of 30) 10-15 14-16 BLUE
13X10 10
ITEM NUMBER 13X15 15 HWCC2 (Bag of 20) 15-30 10-12 YELLOW
MFBP10G RPM0123 15 NOTE: Initial supply is provided with mold power
MFBP30G RPM0124 .062 input connectors.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 127

Smart Series® Mainframe Connector Wiring

Standard Mainframe Connector Wiring

Side of
Mainframe

Smart Series®
|
Smart Series® Mainframe Connector Wiring
High Power Mainframe Connector Wiring

Side of
Mainframe

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® | Wiring Diagram with Smart Series® Mold Connectors 128

U.S. 800-626-6653

BLACK (+)
WHITE (-)

Canada 800-387-6600

Smart Series®

CHECK CONNECTIONS OF BLACK BLK BLK BLK

BETWEEN BLK & WHITE LEADS.


with Smart Series® Mold Connectors

[email protected]

Wiring Diagram for DME Hot Runner Molding System

www.dme.net
NOTES: All grounds must be connected to mold to ensure operator safety.
All crimp connections can be eliminated by using terminal mounting box with terminal strip. See page 135.
BLACK (+)

U.S. 800-626-6653
WHITE (-)


BLACK WHITE

Canada 800-387-6600

Smart Series®

[email protected]
CHECK CONNECTIONS OF BLACK AND WHITE LEADS TO ENSURE


with High Power Smart Series® Mold Connectors
Wiring Diagram for DME Hot Runner Molding System

USE OHM METER TO MEASURE BETWEENF BLACK AND WHITE LEADS .

www.dme.net
NOTES: All grounds must be connected to mold to ensure operator safety.
All crimp connections may be eliminated. Simply remove 6" leads form PIC connectors and wire directly.

Wiring Diagram with High Power Smart Series® Mold Connectors Smart Series®
129

|
130 Smart Series®

Mold Power and Thermocouple Cables

Mold Power Cables are used to connect the Mainframe to the Power Input Connector on the
mold. Available in lengths of 10, 20 or 30 feet. Integral retaining latches on both the frame and
mold connectors provide secure cable connections. Connector configurations ensure proper
insertion of cable. Cables are wired for 5, 8 or 12 zones (15 AMP) and 3 or 5 zones (30 AMP)
MPC12C10G for use with the appropriate Smart Series Mainframes and Mold Power Input Connectors.

Universal Mold Power Cable (15 AMP)


The MPC12C10G, 20G or 30G Mold Power Cable also serves as a universal cable for connecting
any 15 AMP Smart Series Mainframe to any 15 AMP Mold Power Input Connector. The maximum
number of zones will be determined by the connector in the mold.

Mold Power Cables (15 AMP Max)


10 FOOT LONG 20 FOOT LONG 30 FOOT LONG NUMBER FOR CONNECTIONS
OF ZONES
ITEM ITEM ITEM FROM 15 AMP TO POWER INPUT
(MAX.)
NUMBER NUMBER NUMBER FRAME (S) CONNECTOR
MPC5C10G MPC5C20G MPC5C30G 5 5, 8, 12 ZONE PIC5G
Mold Power and Thermocouple Cables

MPC8C10G MPC8C20G MPC8C30G 8 8, 12 ZONE PIC8G


MPC12C10G MPC12C20G MPC12C30G 12 12 ZONE PIC12G

Mold Power Cables (30 AMP Max)


Special Cables 10 FOOT LONG 20 FOOT LONG FOR CONNECTIONS
NUMBER OF ZONES
Virtually any type of ITEM ITEM FROM 30 AMP TO POWER INPUT
(MAX.)
Conversion or Special Cable NUMBER NUMBER FRAME (S) CONNECTOR
configuration can be provided MPCH23C10G MPCH23C20G 3 2-3 ZONE PICH23G
by special order MPCH5C10G MPCH5C20G 5 5 ZONE PICH5G

Thermocouple Cables are used to connect the Mainframe to the Thermocouple Connector on
the mold, and are available in lengths of 10, 20 of 30 feet. Integral retaining latches on both
the frame and mold connectors provide secure cable connections. Connector configurations
|

ensure proper insertion of cable. Cables available are wired for 5, 8 or 12 zones for use with
Smart Series®

TC12C10G the appropriate Smart Series Mainframes and Thermocouple Connectors.

Thermocouple Cables (for use with 15 or 30 AMP Mainframes)


These Thermocouple Cables serve as cables for connecting dissimilar Mainframes and
Thermocouple Connectors. For example. the TC8C10G could be used to connect a 12-zone
frame to an 8-zone MTC8G connector. The maximum number of zones will be determined by
the connector in the mold.

Thermocouple Cables
10 FOOT LONG 20 FOOT LONG 30 FOOT LONG NUMBER FOR CONNECTIONS
OF ZONES
ITEM ITEM ITEM FROM 15 AMP TO THERMOCOUPLE
(MAX.)
NUMBER NUMBER NUMBER FRAME (S) CONNECTOR
TC5C10G TC5C20G TC5C30G 5 5, 8, 12 ZONE MTC5G
TC8C10G TC8C20G TC8C30G 8 8, 12 ZONE MTC8G
TC12C10G TC12C20G TC12C30G 12 12 ZONE MTC12G
* Used with all 30 AMP Mainframes.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series®
131

RoHS/WEEE Compliant: Mold Power Input Connectors

For 15 AMP Mold Power Input Connectors are mounted on the mold to accept power cable(s) from
Applications the Mainframe. They are supplied with six inches of numbered leads and a ground wire.
All three 15 AMP connectors are the same physical size and use 14-gauge wire. Only the
number of active pins change. The 30 AMP connectors are supplied with 10-gauge leads
and are attached to screw terminals. Each is equipped with an integral retaining latch to
provide a secure cable connection. Connector configuration ensures proper insertion of
PIC5G
cable. Splicing of 6" leads to heater power leads is easily accomplished with the Insulated
Crimp Connectors supplied.

NOTE: G
 round wire must be
connected to mold to
ensure operator safety.

PIC8G Mold Power Input Connectors

Smart Series®
PIC12G

|
NOTE: Replacement
 parts and

Mold Power Input Connectors


For 30 AMP
extraction tools can be
Applications found on page 146

NOTE: Dimensions shown may vary slightly.

PICH23G Insulated Crimp Connectors

PICH5G
NOTES: NOTE: Initial supply is provided with
Connector PICH23G is mold power input connectors.
dimensionally identical to Also, see page 126.
thermocouple connector
MTC8G. See next page.
For PICH23G and PICH5G,
direct wiring without crimp
connectors is possible by
removing 6" leads.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


132 Smart Series®

RoHS/WEEE Compliant: Mold Thermocouple Connectors

Thermocouple Connectors are mounted on the mold to use with thermocouple


cable(s) from the Mainframe. Screw type terminals for use with iron(+) and
constantan(-) thermocouple leads are numbered and coded on the side and bottom
of each connector. All three connectors are equipped with integral retaining latches
MTC5G to provide a secure cable connection. Connector configuration ensures proper
insertion of cable. Pins are made of copper alloy and are silver plated. Experience
has proven that iron and constantan are not required.

MTC8G
Mold Thermocouple Connectors

NOTE: MOLD POWER INPUT CONNECTOR PICH23G IS DIMENSIONALLY IDENTICAL TO MTC8G

MTC12G Mold Thermocouple Connector Mold power and Thermocouple


MTC5G Connector TPC0001
MTC8G
MTC12G
|
Smart Series®

tpc0001

* Use with 2, 3 and 5-zone, 30 AMP


mainframes

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 133

Mold Connector Pocket Layouts

NOTE: Drawing depicts Where space or mold handling and storage requirements do not permit the use of
below-flush mounting. Terminal Mounting Boxes, the connectors can be below-flush or surface mounted.
Disregard dimensions
marked with * for
See drawings below and next page for dimensions.
surface mounting.

Smart Series®
|
Mold Connector Pocket Layouts
NOTE: Disregard dimensions
marked with * for
surface mounting.

NOTE: Mold power input connector PICH23G is


dimensionally identical to MTC8G.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


134 Smart Series®

Mold Connector Pocket Layouts


Mold Connector Pocket Layouts

NOTE: Drawing depicts below-surface mounting. Disregard dimensions marked with * for surface mounting.
|
Smart Series®

(Use pocket dimensions shown on pages 131-132 as detailed for thermocouple connector MTC8G.)

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 135

RoHS/WEEE Compliant: Terminal Mounting Boxes

Pre-wired combination terminal mounting boxes


Includes terminal strip for ease of wiring, all necessary connectors installed, and power
connector pre-wired to a terminal strip. All units shown without covers.

PTC5TBGts PTC8TBGts PTC12TBGts

PTC5TBts PTC8TBts PTC12TBts

Smart Series®
PTC2TBGTS is not to be used with SSH1022,

|
Terminal Mounting Boxes
SSH1021, MFP1G, MFP1G1, MFP2G,
MFPR2G controls & mainframes

PTC210TBGts

Combination Terminal Mounting Boxes – with Terminal Strip


ITEM NUMBER X Y H M1 M2 ACCEPTS
PTC210TBGTS* 2.75 4.88 4.25 1.500 4.250 MPTC10/MPTC20
PTC2TBGTS* 2.75 4.88 4.25 1.500 4.250 PTC0110/PTC0120
PTC5TBGTS** 2.75 8.66 4.25 1.500 8.031 MPC5C(10 or 20)G/TC5C(10 or 20)G
PTC8TBGTS** 2.75 9.47 4.25 1.500 8.843 MPC8C(10 or 20)G/TC8C(10 or 20)G
PTC12TBGTS** 2.75 10.53 4.25 1.500 9.906 MPC12C(10 or 20)G/TC12C(10 or 20)G
PTC24TBGTS** 4.18 10.53 4.10  3.25 9.91 (2) MPC12C(10 or 20)G / (2) TC12C(10 or 20)G
PTC36TBGTS** 4.18 16.50 4.10 3.25 15.88 (3) MPC12C(10 or 20)G / ( 3) TC12C(10 or 20)G,
PTC5TBTS** 5.00 6.13 5.12 2.625 5.000 MPC5C(10 or 20)G/TC5C(10 or 20)G
PTC8TBTS** 5.00 6.13 5.12 2.625 5.000 MPC8C(10 or 20)G/TC8C(10 or 20)G
PTC12TBTS** 5.00 6.13 5.12 2.625 5.000 MPC12C(10 or 20)G/TC12C(10 or 20)G
** Comes with all necessary connectors installed and power connector pre-wired to a terminal strip.
* Power and thermocouple connectors are pre-wired.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


136 Smart Series®

Terminal Mounting Boxes


PTC8TBG


PTC5TBG
Terminal Mounting Boxes


Overall dimensions shown include allowances for hardware (assembly screws) but not connectors
PTC0012 †
(example: For Item Number PTC0012 the “X” dimension is 4.29 not including screw heads)
Overall dimensions shown include allowances for hardware (assembly screws) but not connectors
*(example:
Used with For Item15
2-zone, Number PTC0012 the
AMP mainframe “X” dimension
MFFPR2G ** Usediswith
4.291-zone,
not including
30 AMP screw heads)
mainframe MFHP1G
* Used with 2-zone, 15 AMP mainframe MFFPR2G ** Used with 1-zone, 30 AMP mainframe MFHP1G

terminal mounting boxes


|

PIC512TBG
Smart Series®

PTC210 NOTE: Overall dimensions


shown include allowances
Terminal Mounting Boxes provide NOTE:for hardware
Overall (assembly
dimensions
the easiest and most economical screws)include
shown but not allowances
connectors
method of mounting power and for hardware (assembly
thermocouple connectors on the screws) but not connectors

mold. Constructed of plated heavy


gauge steel, each box is precut
and drilled for quick mounting of
the connector to the box, and box
to the mold. Connector mounting
hardware is supplied. Connectors
are ordered separately.
U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net
Smart Series® 137

RoHS/WEEE Compliant: Microprocessor-Based Temperature Control


Modules with Digital Display and Setpoint Pushwheel
COMPATIBLE WITH TAS0512 SSM1512/11 (15 AMP) & SSM3012 (30 AMP)
ALARM AND SYSTEM CONTROL The SSM1512 is the second generation of the popular SSM15G. This version maintains simplicity of operation
with simultaneous display of setpoint and temperature. Other new, improved, and unique features include:
FUNCTIONS. SEE PAGEs 143-144.
Key Features
• Large Digital Display
- For easier readability of temperature, % power and faults
• Setpoint Pushwheel
- For setting desired setpoint temperature
- Allows adjustment of setpoint before turning power on
• Auto % Power Display
- Shows % power output while in AUTO mode
- Indicates average % power requirement on thermocouple failure
- Serves as a diagnostic tool for solving hot runner system problems

Operational Refinements
• Improved SmartStart®
- A more gradual temperature rise leads to a more effective heater dry-out period,
thereby extending heater life
- SmartStart® now available in MANUAL mode (optional)

Smart Series®
• SelectiveCycle®
- A very high speed power output approach
- Enables accurate temperature control and longer heater life
• Bumpless Transfer
- When a thermocouple failure occurs, operation is automatically continued with a learned % power
- Unique software accurately assigns percent power setting

|
• Third Fuse

Control Modules with Digital Display


- Allows for alarm output when the load fuses are blown
- Protects module from application of excessive voltage
• Anti-Arcing Feature
- Protects circuit board from damage when module is either inserted or removed under power

Switchable Options
• Boost, Idle and Power Off Features
- Provides system-wide adjustment of temperatures
- Enables alarm audio/visual output and remote alarms
- Requires TAS0512 module and communications mainframe
(See pages 148-149 for more information on these capabilities)
• Unique AutoBoost Option
- Instantaneously opens frozen gates on startup
- TAS module or mainframe communications are not required
• Lights Out Feature
- After stabilizing at setpoint, display turns off; when a fault occurs, display is turned on and flashes
- For easier detection of faults
• Shorted Thermocouple Sensitivity Adjustment
- Operation can be tailored to fast or slow reaction times
- Sensitivity can be adjusted with internal switches
- Very useful for manifold zones with long startup times
• Switchable °C/°F Operation
- Scale indicated at startup
NOTE: SSM3012 is twice as • K Type Thermocouple Support
wide as above and has • Cut Feature
circuit breaker instead - Gain cut feature for small nozzles and heaters with ungrounded internal thermocouples
of power on/off switch.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


138 Smart Series®
RoHS/WEEE Compliant: Microprocessor-Based Temperature Control
Modules with Digital Display and Setpoint Pushwheel

SSM1512/11 (15 AMP) & SSM3012 (30 AMP)


Warranty: MODULE VOLTAGE
Two years ITEM NUMBER AMPS WATTS
(VAC)
(excluding triac and fuses)
SSM1512 240 15 3600
Fuse Requirements SSM1511 120 15 1800
(15 amp only)
(2) ABC15 fuses (Bussman only) SSM3012 240 30 7200
(2) spare fuses included
with module NOTE: Standard (240 VAC) modules are compatible with mainframes wired for either
240 VAC three phase (standard) or 240 VAC single phase.

Front Panel Controls and Indicators


1. Process Temperature Display
Indicates process temperature, thermocouple faults and other operational modes.
Displays % power when switch (3) is in “% Auto” position.
Control Modules with Digital Display

4
2. Temperature Deviation Lights
1 Indicates deviation from setpoint. Outer lights blink when temperature is more
than ±40˚F (22˚C) from setpoint.
2
3. Auto/Manual/Auto % Power Switch
Selects AUTO or MANUAL control mode. Shows % power when pressed into
“% AUTO” position.

5 4. LED Mode Indicators


Left LED illuminates during manual mode.
Right LED illuminates when power is supplied to heater.
Right LED blinks on and off during SmartStart®.
3
|
Smart Series®

5. Setpoint Pushwheel
Three-digit switch programs setpoint in AUTO mode. Right two digits program
% power in MANUAL mode.

6. Power On/Off Switch


Controls AC power to module.
6

Front Panel Digital LED Indicators

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 139

RoHS/WEEE Compliant: Microprocessor-Based Temperature


Control Modules with Dual Digital Display
COMPATIBLE WITH TAS MODULE
DSS1512/11 (15 AMP) & DSS3012 (30 AMP)
ALARM AND STANDBY HEAT The DSS15 Smart Series Module has dual digital displays providing readouts of both process and
setpoint temperatures at a glance. Closed-loop, fuzzy logic PID control, and auto-tuning of PID
FUNCTIONS. SEE PAGES 143-144.
parameters provide precise control even under the most adverse processing conditions.
In the event of a thermocouple failure, the DSS can automatically invoke bumpless transfer to a
percent power mode based on the last valid percentage learned before the thermocouple failure.
If desired, manual bumpless transfer may be selected, in which case a thermocouple fault will turn
off power to the heater until the manual percent power mode is activated by the operator.
A unique feature of the DSS is a 100% power option. For a switch-selectable, interval of 15 or 30
1 seconds, full power can be immediately delivered to the heater to rapidly break through frozen
gates to achieve quicker start-ups. The 100% power mode can be disengaged at any time by
simply pressing any front panel button.
2 Indicator lights provide quick reference for module control modes, temperature deviation and
3 blown fuses. The process temperature display also provides quick diagnostics of thermocouple
faults, using the following abbreviated codes:
Shi = Shorted thermocouple
oPi = Open thermocouple

Smart Series®
bci = Reversed thermocouple
The DSS module also includes a Smart Start® mode to safely bake out damaging internal heater
4 moisture at system start-up and to prolong heater life. Fast or slow load modes may also be
selected
5
to protect smaller heaters or compensate for “slow” loads such as externally heated manifolds.
6 An accurate, durable and full-featured module, the DSS is fully compatible with all Smart Series
10
7 or G-Series® 15 amp mainframes.

|
Front Panel Controls and Indicators

Control Modules with Dual Digital Display


8
11
9 1. Smart Start Light
Indicates Smart Start is on.
12
2. Process Temperature Display
Indicates process temperature and thermocouple faults as described above.
3. Temperature Deviation Lights
Indicates deviation from setpoint. Outer lights blink at more than ±30°F from setpoint.
13 4. Setpoint Display
Indicates setpoint temperature or percent power, depending on controller mode.
5. Auto/Manual Switch
Selects auto or manual control mode.
6. Auto Light
Indicates auto mode.
7. Manual Light
Indicates manual mode.
8. 100% Power Switch
Indicates 100% power output for selectable interval of 15 or 30 seconds.
NOTE: DSS3012 is twice as 9. 100% Power Light
wide as above; has Indicates 100% power mode.
circuit breaker instead 10. Up Arrow Front Panel Digital LED Indicators
of F1/F2 lights and power
Increases desired setpoint value.
on/off switch.
11. Down Arrow
Decreases desired setpoint value.
12. F1/F2 Lights
Illuminate when fuse is blown.
13. Power On/Off Switch
U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net
140 Smart Series®
Microprocessor-Based Temperature
Control Modules with Dual Digital Display
DSS1512/11 (15 AMP) & DSS3012 (30 AMP)
Performance Specifications
Auto and Manual Control Modes: Time proportioning/Selective Cycle®
Temperature Range: Ambient to 999°F (537°C)
Control Accuracy: ±1°F (0.5°C) dependent on the total thermal system
Temperature Stability: ± 0.5% of full scale over the ambient range of 32 to 120°F (0 to 50°C)
Calibration Accuracy: Better than 0.2% of full scale
Power Response Time: 0.538 seconds.
Manual Control: Adjustable from 0-100%, maintains output power to within 1% of set point.
Smart Start®: Linear voltage ramping.
Maximum Smart Start Duration: 5 minutes
Smart Start Override Temperature: 256°F (124°C)
100% Power: Applies 100% power to the output. Software selectable inhibit or S = 15, L = 30 seconds.
Operational Mode Priority: · Smart Start® precedes auto mode.
· Thermocouple (T/C) break, reversed or shortened T/C overrides Smart Start and auto modes.
· Manual control overrides auto mode, T/C breaks, reversed or shortened thermocouples.
· Output is inhibited during all fault conditions

Input Specifications
Thermocouple Sensor: Type J, grounded or ungrounded.
External T/C Residence: Less than 0.1°F/ .
T/C Isolation: Isolated by control circuit power supply
Cold Junction Compensation: Automatic, better than 0.03°F/F (0.015°C/°C).
T/C Break, Reversed & Shorted Protection: Automatically inhibits power to heater unless bumpless transfer is invoked.
Input Impedance: 5.6 Megohms
Control Modules with Dual Digital Display

Input Amplifier Stability: Greater than 0.02°F/°F (0.01°C/°C).


Common Mode Rejection Ratio: Greater than 120dB.
Power Supply Rejection: Greater than 110dB.

Output Specifications
Voltage Power Capability: 15 AMP: 240 nominal, single phase, 120 VAC available, 15 amperes, 3600 watts @ 240 VAC (1800 watts @ 120 VAC).
30 AMP: 30 amperes, 7200 watts @ 240 VAC
Output Drive: Internal solid state triac, triggered by zero AC crossing pulses.
Overload Protection: 15 AMP: Fuses are provided on both sides of AC line.
30 AMP: Fast acting circuit breaker.
Transient Protection: dv/dt and transient pulse suppression included.
Power Line Isolation: Optically and transformer isolated from AC lines. Isolation voltage is greater than 2500 volts.

Controls and Indicators


Auto/Manual Selection: Push-button switch with LED indicators adjacent to switch.
Setpoint Adjustment: Push-button up & down arrow keys.
100% Power Selection: Push-button switch with LED indicator adjacent.
Power On/Off: 16 Amp rocker switch (15 amp) or 30 amp circuit breaker (30 amp). Both are ul, CSA, VDE approved.
Setpoint Display: Three 0.4", seven segment digit display.
Process Display: Three 0.56", seven segment digit display. Also displays alarm codes and flashing “100” for 100˚ power operation.
100% Power Indication: Red LED adjacent to 100% power key flashes. Process display flashes “100.”
Auto Indication: Illuminates green LED adjacent to Auto/Man key.
Manual Indication: Illuminates yellow LED adjacent to Auto/Man key.
|

Smart Start Indication: Illuminates green LED above the process display.
Smart Series®

Shorted T/C Indication: Flashes “Shi” in process display.


Opened T/C Indication: Flashes “oPi” in process display.
Reversed T/C Indication: Flashes “bci” in process display.
Temperature Deviation Indicators: Five separate LEDs: ±20°F/11°C = Red
±10°F/5°C = Yellow
0° = Green.
Blown Fuse Indicators: 2 neon indicators (15 amp only)

Electrical Power Specifications


Input Voltage: 240/120 VAC + 10% -15%
Frequency: 50/60 Hz
DC Power Supplies: Internally generated, regulated and compensated
Module Power Usage: Less than 6 watts, excluding load.
Dimensions: 15 AMP: 2"W x 7"H x 7 1/2"D (5.08 x 17.78 x 19.05 cm)
30 AMP: 4"W x 7"H x 7 1/2"D (10.06 x 17.78 x 19.05 cm)

NOTE: Standard (240 VAC) modules are


compatible with mainframes wired Smart Series Microprocessor-Based Temperature Control Modules
for either 240 VAC three phase
(standard) or 240 VAC single phase. (240 VAC, standard) (120 VAC, optional)
FOR °C OPERATION: Switch to °C on front panel. ITEM NUMBER AMPS WATTS ITEM NUMBER AMPS WATTS
FUSE REQUIREMENTS (15 AMP ONLY):
(2) ABC15 Fuses (Bussman only) DSS1512 15 3600 DSS1511 15 1800
NOTE: (2) spare fuses included with module. DSS3012 30 7200
WARRANTY: Two years (excluding triac and fuses)
U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net
Smart Series® 141
RoHS/WEEE Compliant: Microprocessor-Based Temperature
Control Modules with Color Touch Screen Display

TSM-15-12
The TSM15 Smart Series Module has a color touch screen digital display providing readouts
for Actual Temperature, Current Mode, Percentage Power and Current Reading. Closed-loop,
fuzzy logic PID control, and auto-tuning of PID parameters provide precise control even
under the most adverse processing conditions.

In the event of a thermocouple failure, the TSM can automatically invoke bumpless
transfer to a percent power mode based on the last valid percentage learned before the
thermocouple failure. If desired, manual bumpless transfer may be selected, in which case
a thermocouple fault will turn off power to the heater until the manual percent power mode
is activated by the operator.

The TSM boost level option limits boosting of the temperature by 75°C or 135°F to limit the
degradation of material.

Smart Series®
The TSM module also includes a Smart Start® mode to safely bake out damaging internal
heater moisture at system start-up and to prolong heater life. Fast or slow load modes
may also be selected to protect smaller heaters or compensate for “slow” loads such as
externally heated manifolds. An accurate, durable and full-featured module, the TSM is
fully compatible with all Smart Series or G-Series® 15 AMP mainframes.

|
Control Modules with Color Touch Screen Display
Leak Detection capabilities (reference TSM1512 User Manual)

TSM15 SmartSeries® Controller with Default Settings (Factory Settings)

Zone temperature 260ºC or 500ºF


Standby level 100ºC or 180ºF
Boost level 75ºC or 135ºF
Over temperature range
10ºC or 18ºF
Under temperature range
Ramp On
Auto-Manual On
Extended alarms for Manual, Standby and
Off
Boost
When reconfiguring your controller for a new tool or environment, this chapter of the manual shows
how to alter controller default settings to your preferred values and afterward to save them.

Should anything seem wrong with your new settings then it is possible to restore the default settings
at any time.

1 Actual temperature (and scale)


Front Panel Controls
2 Current mode shows set-point and Indicators
3 Percentage power applied
4 Current reading

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


142 Smart Series®
RoHS/WEEE Compliant: Microprocessor-Based Temperature
Control Modules with Color Touch Screen Display

Individual Card Diagnostics


The control system has several features which provide a diagnosis of faults in the control system, the tool heaters and thermo-
couple sensors.

If a zone temperature is seen to deviate from the actual setting beyond the alarm limits then the display will change to White
text in Red box and generate a remote alarm.

The following is a list of alarm conditions that may be detected and which will also activate
the output contacts.

Error Message Cause Action


Little or no temperature rise has been detected in that
zone. When the console starts to apply power it expects
to see an equivalent heat rise at the thermocouple. If the
Control Modules with Color Touch Screen Display

thermocouple has been trapped and pinched elsewhere


Check thermocouple wiring; it may be reversed. Heater
ERR! in the tool or cable then it cannot sense the full heat rise that
wiring may be faulty or element may be open circuit.
occurs at the tip. If left uncorrected, there is a danger that the
zone could overheat and damage the tip. Instead the circuit
maintains the output at whatever level it reached when the
monitor circuit detected the fault.
The output fuse for that zone has failed. Please note:
A fuse can only fail due to a fault external to the controller.
Identify and rectify the fault before replacing the fuse.
Note: The fuse detection circuit requires a continuous low level
current through a high impedance bleed resistor to maintain the Replace the fuse with one of the same rating and type;
FUSE alarm condition. As a result the load circuit is still connected to i.e. High Rupture Current load fuse. The blown fuse is
the main’s voltage supply and it is not safe to attempt to repair located on the control card.
or replace the fuse without first isolating the circuit. If the fuse
in question is mounted on a control card then it is safe to unplug
the board in order to isolate the circuit and replace the fuse on
the card.

Check your heater wiring for a low impedance path to


GND The system has detected an ground fault.
the ground.
|
Smart Series®

There is a phase detection circuit on each TMS15-Series


No mains supply synchronization pulses being received. The card and a common phase detection circuit on all other
3-phase supply is used in a cross-over detection circuit to gener- controller types. Although a fault in such circuits may
ate timing pulses for accurate phase control and firing the triac. cause the LINE error message, such fault is very rarely
LINE If the phase detection fails on one or two phases then there is seen. The most common error is either the absence of
no pulse to use to measure phase angle and the LINE error mes- one phase or, if a plug has been re-wired incorrectly, a
sage is generated. Meanwhile, all circuits on the healthy phases swapped phase and neutral. If a LINE error message oc-
will continue to work normally. curs then switch off and isolate the controller then check
supply wiring for presence of all three phases.

The card has detected an abnormal input at the T/C termination If the REV alarm persists, switch off the controller and
REV
that indicates a shorted or reversed thermocouple. investigate the offending zone.
For immediate recovery, change to open loop control.
Make a note of the above action so that when the
An open circuit thermocouple has been detected and no auto-
controller is free you can check to see whether the input
T/C response has been selected in the T/C Open Error column of the
fuse on the control card has ruptured. If the fuse is good
Setup page.
then you may need to check the wiring for faults or even
replace the thermocouple.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 143

Temperature Alarm/System Control Modules

TAS0512/11 Temperature Alarm Function


• Provides alarm for over or under temperature, or diagnostic error
• Provides visual and audible indications of an alarm
1 • The audible alarm (2) can be turned on or off with switch (4)
• Relay contacts (5) are provided to allow hook-up of remote equipment such as a light,
a conveyor or a machine function
• Relay contacts are unaffected by the position switch (4)
2
• An infinite number of zones of control can be monitored as long as they are contained within
the same communications-style mainframe as the TAS module

3 System Control Functions


Up to 63 zones can be controlled remotely at one time. These zones must be contained within
4 the same communications-style mainframe as the TAS module.
5

Smart Series®
NORMAL / IDLE
• Rotary switch (6) provides remote control of DSS1502/01, DSS1512/11, CSS1502/01,
SSM1502/01, and SSM1512/11
• Control modules can all be commanded to respond from NORMAL to IDLE (Standby Heat)
6
• In IDLE, the modules will adjust to a setting of 93˚C (200°F)

|
Exceptions: SSM1502/01 and SSM1512/11 adjust to a setting of 100˚C (212°F)

Temperature Alarm/System Control Modules


• Moving the rotary switch back to NORMAL restores all modules to their established setpoints
• The user can select IDLE for temporary lowering of all zones to prevent material degradation
• This feature can be used to keep heaters warm enough to prevent absorption of moisture
7

BOOST / OFF
• The SSM1502/01 and SSM1512/11 can be placed into BOOST and OFF
• BOOST will raise the setpoint of the module by 10, 20, or 30%
• OFF shuts off power to the heater but allows the user to monitor cool down of the
hot runner system
• Each SSM1502/01 and SSM1512/11 can be individually programmed to respond to OFF,
IDLE and BOOST commands
• The user can quickly drive all nozzle zones into BOOST to open frozen gates

Front Panel Controls and Indicators


1. Power On Indicator: LED illuminates when power is applied to the module.
2. Audible Alarm: Emits a loud audible alarm when the alarm switch (4) is placed in the
“1” position (on) and an alarm condition is sent by a compatible control module.
3. Alarm Indicator: LED illuminates when an alarm condition is sent by a compatible module.
4. Audio Alarm On/Off Switch: Turns the audio alarm (2) on or off.
5. Alarm Relay Connector Provides relay contacts for use with remote equipment.
Mating connector is supplied.
6. System Control Switch: Activates the OFF, IDLE and BOOST mode in all
compatible modules.
7. Power On/Off Switch: Controls AC power to the module.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


144 Smart Series®

Temperature Alarm/System Control Modules

ITEM NOTE: Standard (240 VAC) modules are compatible with mainframes wired for either 240 VAC
VOLTS three-phase (standard) or 240 VAC single-phase. Use TAS0511 for 120 VAC operation.
NUMBER
TAS0512 240 VAC FUSE REQUIREMENTS: (2) ABC1 fuses. NOTE: (2) spare fuses included with module.
TAS0511 120 VAC WARRANTY: Two years (excluding fuses).
Note:
Tas Module Compatibility TAS module is not compatible with older CSS15G/30G or DSS15G/30G modules.
MODULE FUNCTIONS MODULE FUNCTIONS
ALARM IDLE BOOST OFF ALARM IDLE BOOST OFF
SSM1502/01/12/11 CSS1502/01
SSM3002/12 CSS3002
DSS1502/01/12/11 SSM15G
DSS3002/12 SSM15G1
TSM1512 SSM30G
Temperature Alarm/System Control Modules

BOOST
The “BOOST” setting is the normal setpoint plus 10, 20, or 30%; for example,
BOOST if setpoint = 500˚F and BOOST is 10%, then BOOST temperature = 550˚F.

NORMAL “NORMAL” operation is as though Remote


NORMAL
the TAS module is not present. Control
Functions

IDLE “IDLE” (Standby heat) reduces heat to 200˚F or 212˚F.


IDLE
93˚C (200˚F)
or
100˚C (212˚F)

OFF “OFF” cuts power to the heater:


AMBIENT The user can monitor cool down.

TIME
|
Smart Series®

Upgrade Kits For Converting to Communications Mainframes

ITEM NUMBER MAIN FRAME ITEM NUMBER MAIN FRAME

CIK4 4-ZONE CIK28 28-ZONE


CIK5 5-ZONE CIK32 32-ZONE
CIK7 7-ZONE CIK36 36-ZONE
CIK8 8-ZONE CIK40 40-ZONE
CIK11 11-ZONE CIK44 44-ZONE
CIK12 12-ZONE CIK48 48-ZONE
CIK16 16-ZONE CIK2HP 2-ZONE HIGH POWER
CIK20 20-ZONE CIK3HP 3-ZONE HIGH POWER
CIK24 24-ZONE CIK5HP 5-ZONE HIGH POWER

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 145

Replacement Parts and Service Items for DME


Smart Series® Temperature Control Systems

Smart Series®
|
Replacement Parts for Smart Series® Temperature Control Systems
NOTE: For upper inside communications connectors, see previous page.

Connectors / Connector Kits (5-48 zone, 15 Amp; 2-5 zone, 30 Amp)


REFERENCE
DESCRIPTION ITEM NUMBER
LETTER
A Mold Thermocouple Output Connector see page134
132
B Mold Power Input Connector see page133
131
Mold End Kit for 5-Zone Thermocouple Cable (10, 15 or 30 AMP) CKTF15G
C Mold End Kit for 8-Zone Thermocouple Cable (10, 15 or 30 AMP) CKTF18G
Mold End Kit for 12-Zone Thermocouple Cable (10, 15 or 30 AMP) CKTF112G
Mold End Kit for all 10 or 15 AMP Power Cables CKPF112BG
D Mold End Kit for all 2 or 3-Zone 30 AMP Power Cables CKPF13CG
Mold End Kit for all 5-Zone 30 AMP Power Cables CKPF15CG
E Frame End Kit for all Thermocouple Cables (10, 15 or 30 AMP) CKTF112AG
Frame End Kit for all 10 or 15 AMP Power Cables CKPM112BG
F Frame End Kit for 2 or 3-Zone 30 AMP Power Cables CKPM13CG
Frame End Kit for all 5-Zone 30 AMP Power Cables CKPM15CG
G Thermocouple Input Kit for all Mainframes (10, 15 or 30 AMP) CKTM212AG
Power Output Kit for all 10 or 15 AMP Power Cables CKPF212BG
H Power Output for all 2 or 3-Zone 30 AMP Power Cables CKPF32CG
Power Output Kit for all 5-Zone 30 AMP Power Cables CKPF25CG
I Edge Card Connector Kit for all Mainframe PC Boards (10, 15 or 30 AMP) CKF312G

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


146 Smart Series®
Replacement Parts and Service Items for DME
Smart Series® Temperature Control Systems

mainframe, cable components, and service tools*


cbd10m 10 amp 2 pole, circuit breaker used in mfp1g and mfp1g1
cbd20m 20 amp 2 pole, circuit breaker used in mfr2g
cbd30m 30 amp 2 pole, circuit breaker used in mffpr2g and mfhp1g
cbd50 50 amp 3 pole, circuit breaker used in 5 through 12 zone mainframes
cbd70 70 amp 3 pole, circuit breaker used in 16 through 48 zone & high power mainframes
pin0114 14 gauge male pin for “b”& “f” power connectors (package of 30) SEE Previous page
pin0214 14 gauge female socket for “d”& “h” power connectors (package of 30) SEE Previous page
pin0120 20 gauge male pin for “g” thermocouple connector (package of 30) SEE Previous page
pin0220 20 gauge female pin for “e” thermocouple connector (package of 30) SEE Previous page
wht1919 crimp tool for all pin-xxxx listed above
rpm0048 extraction tool for all pin-TYPE connector PINS
Replacement Parts for Smart Series® Temperature Control Systems

rpm0038 neon indicators used on 240 vac mainframe circuit breaker panels
rpm0044 card guides for all mainframes
rpm0046 pins for white edge card connectors “I” (package of 20)
rpm0059 panel mount base & latch for 5-zone thermocouple mold connection “a” SEE Previous page
rpm0060 panel mount base & latch for 8-zone thermocouple mold connection “a” SEE Previous page
rpm0061 panel mount base & latch for 12-zone thermocouple mold connection “a” SEE Previous page
rpm0062 male insert for 5 zone thermocouple mold connection “a” SEE Previous page
rpm0063 male insert for 8-zone thermocouple mold connection “a” SEE Previous page
rpm0064 male insert for 12-zone thermocouple mold connection “a” SEE Previous page
rpm0065 female insert for 5-zone thermocouple cable connector “c” SEE Previous page
rpm0066 female insert for 8-zone thermocouple cable connector “c” SEE Previous page
rpm0067 female insert for 12-zone thermocouple cable connector “c” SEE Previous page
rpm0068 hood for 5 zone thermocouple cable connector “c” SEE Previous page
rpm0069 hood for 8 zone thermocouple cable connector “c” SEE Previous page
rpm0070 hood for 12 zone thermocouple cable connector “c” SEE Previous page
rpm0071 hood for 5, 8 & 12 power & thermocouple cable connections “d”,“e” & “f” SEE Previous page
rpm0072 male insert for “b”, “f” & “g” (15 amp connector rating is exclusive to DME) SEE Previous page
rpm0073 female insert for “d”, “e” & “h” (15 amp connector rating is exclusive to DME) SEE Previous page
*(reference page 134-147 for letter designations)

All Smart Series Modules


ABC1 1 AMP 250 VAC FUSE
ABC3 3 AMP 250 VAC FUSE - NOTE: THESE LOWER POWER FUSES ARE RECOMMENDED FOR NOZZLES
|

ABC5 5 AMP 250 VAC FUSE - NOTE: THESE LOWER POWER FUSES ARE RECOMMENDED FOR NOZZLES
Smart Series®

ABC10 10 AMP 250 VAC FUSE - NOTE: REQUIRED FOR 15 AMP MODULES USED IN 10 AMP FRAMES
ABC15 15 AMP 250 VAC FUSE
RPM0123 15 AMP 250 VAC FUSE - ULTRAFAST
RPM0124 .062 AMP TC FUSE FOR TSM MODULES ONLY
NYL0001 “NYLATCH” MODULE RETENTION PLUNGER AND GROMMET (10/PKG) - note: at the bottom of each module
RPM0008 POWER ROCKER SWITCH FOR ALL MODULES EXCEPT DSS AND CSS1524
RPM0009 TRANSFORMER TYPE DST416 FOR ALL MODULES EXCEPT DSS & TAS
RPM0027 ALUMINUM HANDLE FOR 15 AMP MODULES
RPM0039 30 AMP 2 pole, CIRCUIT BREAKER FOR MODULES
RPM0023 TRIAC - TYPE Q6040P 40 AMP 600 VOLT FOR USE ON ALL MODULES
RPM0054 TRIAC - TYPE BTA40800B 40 AMP 800 VOLT FOR USE ON ALL MODULES EXCEPT CSS
RPM0050 2200 OHM FLAME PROOF FUSIBLE LINK RESISTOR USED IN THERMOCOUPLE CIRCUIT (10/PK) USED ON ALL MODULES
RPM0088 A/D CONVERTER FOR SSM15G, SSM15G1, SSM30G, SSH1001, SSH-1002 AND ALL CSS MODULES
U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net
Smart Series® 147

Replacement Parts and Service Items for DME


Smart Series® Temperature Control Systems

Smart Series®
|
Replacement Parts for Smart Series® Temperature Control Systems

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


148 Smart Series®

Input Power Wiring Diagrams (Option A)

The diagrams on pages 148 through 150 are printed on the back panels of the mainframes.
For your convenience, they are depicted here along with additional information.
For information on input wiring for 30 amp mainframes, contact DME.

Standard input wiring for mainframes, unless specified otherwise at time of order, is 240 VAC,
three- phase, 4-wire, 50/60 Hz. (OPTION A). If it becomes necessary to change to another
configuration, refer to the appropriate diagram and information on the following pages:
Page 148: (OPTION A) 208-240 VAC, 3-phase, 4-wire
Page 149: (OPTION B) 380-415 VAC, 3-phase, 5-wire
Page 150: (OPTION C) 240 VAC, 2-phase, 4-wire
(OPTION D) 208-240 VAC, single phase, 3-wire 120 VAC, 2-phase, 4-wire

Note: For mold power and thermocouple connector wiring information, see pages 128-129.
Input Power Wiring Diagrams (Option A)

OPTION A 208 – 240 VAC, Three-Phase, 4-wire Delta


(Standard) or “Y” Power Distribution System
|
Smart Series®

As shown above, each module is powered from one of the three phases. Zone (1), for
example, is powered from Phase 1, which is supplied by R/L1 and S/L2. Zone (2) is
powered by Phase 2, which is supplied by S/L2 and T/L3. Zone (3) is powered by Phase
3, which is supplied by R/L1 and T/L3.

NOTE: At this point, the sequence repeats itself. For example, Zone (4) is connected
the same as Zone (1) to R/L1 and S/L2 and Zone (5) is connected the same as Zone (2) to
S/L2 and T/L3 and Zone (6) is connected the same as Zone (3) to R/L1 and T/L3. Zone (7)
is then connected to the same phase as Zone (1) and (4), etc. This method of connection
assures the greatest likelihood of line balance.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 149

Input Power Wiring Diagrams (Option B)

OPTION B 380 – 415 VAC, Three-Phase, 5-wire


“Y” Power Distribution System

Smart Series®
CAUTION note: The voltages from line-to-line in this system are 380 to 415 volts. Severe damage to module and

|
Input Power Wiring Diagrams (Option B)
mainframe could result if this type of AC input system is connected to a mainframe wired as OPTION A. This type of power
distribution is not found or is very uncommon in the United States but is the most common system found in many other
countries worldwide.

WARNING: If export of this system is intended, make sure that wiring is reconfigured for the country where it is to be used.

Please note that the 380-415 Volt Power Distribution System is the same as the “Y” connection shown in OPTION A except
for the voltage levels and the use of the MP/N to develop the 240 volt from the 380-415 volt system. Notice that all modules
have one line connected to MP/N and the other side connected to one of the three phase lines.

Example: Zone (1) is connected to Phase 1, which is supplied by R/L1 and MP/N.
Zone (2) is connected to Phase 2, which is supplied by S/L2 and MP/N.
Zone (3) is connected to Phase 3, which is supplied by T/L3 and MP/N.
Zone (4) starts the sequence over again. It is connected to Phase 1 R/L1
and MP/N, etc.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


150 Smart Series®

Input Power Wiring Diagrams (Options C and D)

Example: Zone (1) is connected to MP/N and R/L1. Zone (2) is connected to MP/N and S/L2, etc.
Zone (3) starts the sequence over again. It is connected to MP/N and R/L2, same as zone (1).

OPTION C 240 VAC, Two-Phase, 4-wire


Input Power Wiring Diagrams (Options C and D)

The 240 volt single-phase connection only uses two power lines plus ground.
CAUTION: Only power conductors should be connected through the circuit breaker. Never make ground
connections through a circuit breaker. Notice that the output of the circuit breaker is connected to terminal strips
R/L1 and S/L2. Also notice that ground is common with MP/N in this system. All zones in this system have to be
connected to MP/N and either R/L1 or S/L2. Line balance is achieved by alternating between R/L1 and S/L2.

OPTION D 208 – 240 VAC, Single-Phase, 3-wire or 120 Vac,


Two-Phase, 4-Wire
|
Smart Series®

Above diagram depicts two different wiring configurations. One is 208-240 volt, single-phase, 3-wire. Note that
lines R/L1 and S/L2 are connected through the circuit breaker to the appropriate terminal strips. All zones will be
connected between R/L1 and S/L2. MP/N is common with ground and is not connected through the circuit breaker.
In the 120 volt connection (zone connections shown within the dashed-line area), the 120 volts is developed between
R/L1 and MP/N and S/L2 and MP/N. Again, ground and MP/N are not connected through the circuit breaker. Each
zone in this system will be connected to MP/N and either R/L1 or S/L2. Line balance is achieved by alternating
between R/L1 and S/L2.
U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net
Smart Series® Alternate Connectors 151

Alternate Cable Configuration


Mold-Masters to DME Smart Series Conversion Cables

Smart Series® Alternate Connectors


Combination Mold Power and Thermocouple Conversion Cables allow
ease of conversion between Mold-Masters and DME systems

• Mold Power and Thermocouple combined in a single cable


• Conversion for 12 zones
• Cables available in standard lengths of 10’ and 20’ (custom lengths are
available)

|
Mold Power Thermocouple Cable Mainframe Mold

Mold-Masters to DME Smart Series


Item Number Zones Zones Length Connector Connector Splits

PITC1210YFE 10’ HBE48


DME “G” (Mold 5
Series Master (Frame End)
PITC1220YFE 20’ MPlug.12)
12 12
PITC1210YME 10’ HBE48
(Mold DME “G” 5
Master Series (Mold End)
PITC1220YME 20’ MPlug.12)

Works with the following connectors:

PIC12G MTC12G MPlug.12

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® Alternate Connectors | Mold-Masters to DME Smart Series 152

5-ZONES OF CONTROL
B PTCO5TB 5-ZONE TERMINAL MOUNTING BOX
C MPCO5C10 OR 20G 5-ZONE MOLD POWER CABLE; 10' OR 20' O.A.L.

U.S. 800-626-6653

D PICO5 5-ZONE MOLD POWER INPUT CONNECTOR
E TCO5C10 OR 20G 5-ZONE THERMOCOUPLE CABLE; 10' OR 20'
O.A.L.
F MTCO5 5-ZONE MOLD THERMOCOUPLE CONNECTOR

A
8-ZONES OF CONTROL
B PTCO8TB 8-ZONE TERMINAL MOUNTING BOX
F E
C MPCO8C10 OR 20G 8-ZONE MOLD POWER CABLE; 10' OR 20' O.A.L.
D PICO8 8-ZONE MOLD POWER INPUT CONNECTOR

Canada 800-387-6600
THERMOCOUPLE


E TCO8C10 OR 20G 8-ZONE THERMOCOUPLE CABLE; 10' OR 20'
O.A.L.
B
F MTCO8 8-ZONE MOLD THERMOCOUPLE CONNECTOR
Smart Series® Alternate Connectors

12-ZONES OF CONTROL
MOLD POWER
Alternate Cable Configuration

B PTCO12TB 12-ZONE TERMINAL MOUNTING BOX


C MPCO12C10 OR 20G 12-ZONE MOLD POWER CABLE; 10' OR 20' O.A.L.

[email protected]
D PICO12 12-ZONE MOLD POWER INPUT CONNECTOR


HUSKY COMPATIBLE CONTROL SYSTEM COMPONENTS

D C A E TCO12C10 OR 20G 12-ZONE THERMOCOUPLE CABLE; 10' OR 20'


O.A.L.
F MTCO12 12-ZONE MOLD THERMOCOUPLE CONNECTOR

Husky is a trademark of
Husky Injection Molding Systems

www.dme.net
HEATER POWER LEADS
DISTRIBUTOR TUBE OR MANIFOLD HEATER (ZONE 1)
MOLD POWER
INPUT CONNECTORS MOLD THERMOCOUPLE CONNECTORS REAR
REAR
2 3 4 5 6 7 8 9 10 11 12 THERMOCOUPLE LEADS 13 14 15 16 17 18 19 20 21 22 23 24 VIEW
VIEW
WHITE (-)
BLACK (+)

PICO12
MTCO12

U.S. 800-626-6653
13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12


1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

PICO8
9 10 11 12 13 14 15 16 TYPE “J”
T/C ONLY

MTCO8
1 2 3 4 5 PROBE OR 1 2 3 4 5 6 7 8
NOZZLE 6 7 8 9 10
HEATER

PICO5
6 7 8 9 10
MTC05
Z 1 2 3 4 5
ZONE BEFORE POWER BEFORE POWER IS
1 13 1 9 1 6 ZONE 1 IS CONNECTED: CONNECTED:

Canada 800-387-6600
O ZONE BLK WHT BLK WHT BLK WHT


2 14 2 10 2 7 ZONE 2 • USE OHM METER TO
CHECK EACH HEATER
ZONE 1 1 6 1 9 1 13
3 15 3 11 3 8 ZONE 3 POWER LEAD. RESISTANCE
N ZONE 2 2 7 2 10 2 14
4 16 4 12 4 9 ZONE 4 TO GROUND SHOULD BE ZONE 3 3 8 3 11 3 15
5 17 5 13 5 10 ZONE 5 GREATER THAN 20,000 E
OHMS. ZONE 4 4 9 4 12 4 16
6 18 6 14 ZONE 6 • CHECK RESISTANCE ZONE 5 5 10 5 13 5 17
7 19 7 15 ZONE 7 BETWEEN HEATER POWER
Smart Series® Alternate Connectors

LEADS. (SEE CALCULATION


ZONE 6 6 14 6 18
8 20 8 16 ZONE 8 ZONE 7 7 15 7 19
BELOW) 1
9 21 ZONE 9 ZONE 8 8 16 8 20
Alternate Cable Configuration

10 22 ZONE 10 2 ZONE 9 9 21
11 23 ZONE 11 ZONE 10 10 22

[email protected]
12 24 ZONE 12 ZONE 11 11 23


HEATER HEATER HEATER ZONE 12 12 24
MEASURED
TYPICAL MOLD CONNECTOR WIRING DIAGRAM (REVISION “A”)

VOLTS VOLTS WATTS RESISTANCE


MARKED ON × MARKED ON ÷ MARKED ON ≅ OHMS
HEATER HEATER HEATER
EXAMPLE: (240 VOLTS) × (240 VOLTS) ÷ 820 WATTS ≅ 70 OHMS
NOTE: ALL GROUNDS MUST BE CONNECTED TO MOLD TO INSURE OPERATOR SAFETY.

www.dme.net
Alternate Cable Configuration
153

| Smart Series® Alternate Connectors


154 Smart Series® Alternate Connectors
Terminal Box Detail & Mold Connectors
EUROPEAN CONFIGURATION

2
E

5
1
4
Terminal Box Detail & Mold Connectors

B
A D
C
3

Callout Number 1 is special B


order with a short lead time;
D
all other items are in stock
A
C

ITEM NUMBER ITEM NUMBER DIMENSIONS


|

CALLOUT CALLOUT
TERMINAL MOLD
Smart Series® Alternate Connectors

NUMBER NUMBER
BOX CONNECTOR A B C D E

1 PTO5TB 2 PICO5 1.50" 38mm 4.25" 108mm 2.44" 62mm 4.88" 124mm 4.10" 104mm
1 PTO5TB 2 MTCO5 1.50" 38mm 4.25" 108mm 2.44" 62mm 4.88" 124mm 4.10" 104mm
1 PTO8TB 2 PICO8 1.50" 38mm 4.99" 127mm 2.44" 62mm 5.61" 142mm 4.10" 104mm
1 PTO8TB 2 MTCO8 1.50" 38mm 4.99" 127mm 2.44" 62mm 5.61" 142mm 4.10" 104mm
1 PTO12TB 2 PICO12 1.50" 38mm 6.05" 154mm 2.44" 62mm 6.68" 170mm 4.10" 104mm
1 PTO12TB 2 MTCO12 1.50" 38mm 6.05" 154mm 2.44" 62mm 6.68" 170mm 4.10" 104mm
3 PTCO5TB 4 PICO5 1.50" 38mm 8.84" 225mm 2.44" 62mm 9.47" 241mm 4.10" 104mm
5 MTCO5 1.50" 38mm 8.84" 225mm 2.44" 62mm 9.47" 241mm 4.10" 104mm
3 PTCO8TB 4 PICO8 1.50" 38mm 9.91" 252mm 2.44" 62mm 10.53" 267mm 4.10" 104mm
5 MTCO8 1.50" 38mm 9.91" 252mm 2.44" 62mm 10.53" 267mm 4.10" 104mm
3 PTCO12TB 4 PICO12 1.50" 38mm 12.17" 309mm 2.44" 62mm 12.79" 325mm 4.10" 104mm
5 MTCO12 1.50" 38mm 12.17" 309mm 2.44" 62mm 12.79" 325mm 4.10" 104mm

NOTE: ALLOW AN ADDITIONAL 0.25" (10mm) IN HEIGHT AND WIDTH FOR SCREW HEAD CLEARANCE

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Smart Series® 155

DME Mainframe Stand Accessory – Cable Storage Basket

FSCB0001 Cable Basket


(Includes (1) 14"- and (4) 6"- long zip ties)

• Compatible with DME Smart Series


• Durable molded plastic construction
• Keep all your cables and connectors safely off the floor

|Smart Series®
Mainframe Stand Accessory – Cable Storage Basket
Note: P
 roduct color may differ from
what is shown.

Smart Series 8-zone stand Smart Series 12-zone stand

Installation Guide
Step 1
Position Basket on bottom of the DME Mainframe Floor Stand.
Decide if you will attach the basket to the right or left Mainframe Upright Post.
Step 2
Secure Basket to Mainframe Floor Stand with Supplied Cable Ties.

Attach Longer Cable Tie to Side Post Attach Shorter Cable Ties to Corners

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Valve Gate C ontrols

Energy efficient, reliable


and compact hydraulic and
pneumatic controls
Valve Gate Controls 157

DME Pneumatic Sequential Valve Gate Controller

The SVG controller provides the user with full control over valve gate flow sequence, critical when
molding complex or large parts. All SVG controllers feature the NEW APS (Adaptive Process System)
technology providing faster processing and response speed.

BENEFITS
• The sequential valve gate technology is integrated in a precise valve gate control unit
with all available features or stand alone unit
• SVGP systems are air cooled & energy efficient
• Designed to easily connect to any valve gate system
• Precise filling control with performance graphs displaying time and position,
with up to 4 steps per cycle
• (2) digital and analog triggers for 2-shot applications

Valve Gate Controls


CONFIGURATION
• Program valve actuation by time or injection screw position
• Pin position feedback for gate open /close confirmation
• Automatic and manual mode for individual gate control
• Absolute and incremental timer selections
• Single or dual acting solenoid valves for gate activation, valve banks re-locatable SVGP

|
• Calibrate analog signals for position, pressure and volumetric settings

DME Valve Gate Controller Products and Solutions


• Reconfigure pin position feedback inputs for 12 additional sequences
• 500 or 1000 Watt 24VDC power supply - Standard 220V single phase (185-245V range)
or Optional 480V three phase

ITEM
Description includes
NUMBER

SVGP2 2 ZONE PNEUMATIC SVG12 HMI, 1-2 SOLENOID VALVE BANK


SVGP4 4 ZONE PNEUMATIC SVG12 HMI, 1-4 SOLENOID VALVE BANK
SVGP6 6 ZONE PNEUMATIC SVG12 HMI, 1-6 SOLENOID VALVE BANK
SVGP8 8 ZONE PNEUMATIC SVG12 HMI, 1-8 SOLENOID VALVE BANK
SVGP12 12 ZONE PNEUMATIC SVG12 HMI, 2-6 SOLENOID VALVE BANKS
SVGPC2 2 ZONE COMPACT PNEUMATIC SVG12C HMI, 1-2 SOLENOID VALVE BANK
svgPc4 4 ZONE COMPACT PNEUMATIC SVG12C HMI, 1-4 SOLENOID VALVE BANK
svgPc6 6 ZONE COMPACT PNEUMATIC SVG12C HMI, 1-6 SOLENOID VALVE BANK
svgPc8 8 ZONE COMPACT PNEUMATIC SVG12C HMI, 1-8 SOLENOID VALVE BANK
SVGPC
svgPc12 12 ZONE COMPACT PNEUMATIC SVG12C HMI, 2-6 SOLENOID VALVE BANKS

If you do not see the number of controlled zones required in the table above please contact us.

Optional Accessories
ITEM Pneumatic Power pack
Description
NUMBER

ITSPTROLLEY Stand Stand


PNEUPP Pneumatic Power Pack 500 PSI

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Valve Gate
textControls
158
158 text
DME Pneumatic Sequential Valve Gate Controller
page content

KEY TECHNICAL FEATURES AT A GLANCE


• Digital outputs – fused at 2 amps
• Digital inputs - pin position back/forward
• Integrated 24 VDC power supply to drive valve gate solenoids
• 7” color touch screen on standalone controller
• Controls single or dual coil solenoid valves
• Real time valve status graph
• Configurable Easy View status page
• NEW SVG Power pack combines hot runner control, SVG,
hydraulic power pack and solenoid valve bank all in one package
DME Valve Gate Controller Products and Solutions
|
Valve Gate Controls

PROGRAMMABLE TRIGGERS & ALARMS


• Digital input – sequence start trigger
• Digital input triggers – programmable sequence triggers
• (2) Analog inputs 0-10 volts
• Analog input 4-20ma
• Remote enable signal – from IMM
• Fault relay output (dry contact) – to IMM
• Dry contact or 24VDC input triggering
Controller includes 15ft (4.8m) solenoid power cord
U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net
Valve Gate Controls 159

DME Hydraulic Sequential Valve Gate Controller

The SVG controller provides the user with full control over valve gate flow sequence, critical when
molding complex or large parts. All SVG controllers feature the NEW APS (Adaptive Process System)
technology providing faster processing and response speed.

BENEFITS
• The sequential valve gate technology is integrated in a precise valve gate control unit
with all available features or stand alone unit
• SVGH6 systems - air cooled & energy efficient
SVGH1200 & 1600 systems - built-in water cooling circuit for the hydraulic power pack
• Designed to easily connect to any valve gate system
• Precise filling control with performance graphs displaying time and position,
with up to 4 steps per cycle
• (2) digital and analog triggers for 2-shot applications

Valve Gate Controls


CONFIGURATION
• Program valve actuation by time or injection screw position
• Pin position feedback for gate open /close confirmation
• Automatic and manual mode for individual gate control
• Absolute and incremental timer selections
• Single or dual acting solenoid valves for gate activation, valve banks relocatable
• Calibrate analog signals for position, pressure and volumetric settings

|
• Configure up to 4 cards to control as many as 48 single acting valve gates

DME Valve Gate Controller Products and Solutions


• Reconfigure pin position feedback inputs for 12 additional sequences
• 500 or 1000 Watt 24VDC power supply - Standard 220V single phase (185-245V range) 3L-1200 PSI / 3L-1600 PSI
or Optional 480V three phase Power pack

• Available as standalone controller or semi-integrated into the TSP or TSP Plus


temperature controller

ITEM pOWER PACK


Description CONSISTS OF
NUMBER psi
SVGH62 2 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 1-2 SOLENOID VALVE BANK, STAND
SVGH64 4 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 1-4 SOLENOID VALVE BANK, STAND
3L-600 PSI
SVGH66 6 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 1-6 SOLENOID VALVE BANK, STAND
SVGH68 8 ZONE HYDRAULIC SVG12 HMI, POWER PACK,1-8 SOLENOID VALVE BANK, STAND
SVGH122 2 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 1-2 SOLENOID VALVE BANK, STAND
SVGH124 4 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 1-4 SOLENOID VALVE BANK, STAND
SVGH126 6 ZONE HYDRAULIC 3L-1200 PSI SVG12 HMI, POWER PACK, 1-6 SOLENOID VALVE BANK, STAND
3L-600 PSI Power pack
SVGH128 8 ZONE HYDRAULIC SVG12 HMI, POWER PACK,1-8 SOLENOID VALVE BANK, STAND
SVGH1212 12 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 2-6 SOLENOID VALVE BANKS, STAND
SVGH162 2 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 1-2 SOLENOID VALVE BANK, STAND
SVGH164 4 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 1-4 SOLENOID VALVE BANK, STAND
SVGH166 6 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 1-6 SOLENOID VALVE BANK, STAND
SVGH168 8 ZONE HYDRAULIC 3L-1600 PSI SVG12 HMI, POWER PACK,1-8 SOLENOID VALVE BANK, STAND
SVGH1612 12 ZONE HYDRAULIC SVG12 HMI, POWER PACK, 2-6 SOLENOID VALVE BANKS, STAND
SVGH1616 16 ZONE HYDRAULIC SVG24 HMI, POWER PACK, 2-8 SOLENOID VALVE BANKS, STAND
SVGH1624 24 ZONE HYDRAULIC SVG24 HMI, POWER PACK, 3-8 SOLENOID VALVE BANKS, STAND

If you do not see the number of controlled zones required in the table above please contact us.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


160
text
160 Valve Gate
textControls

DME Sequential
pageValve Gate Controller
content

KEY TECHNICAL FEATURES AT A GLANCE


• Digital outputs – fused at 2 amps
• Digital inputs - pin position back/forward
• Integrated 24 VDC power supply to drive valve gate solenoids
• 7” color touch screen on standalone controller
• Controls single or dual coil solenoid valves
• Real time valve status graph
• Configurable Easy View status page
• NEW SVG Power pack combines hot runner control, SVG,
hydraulic power pack and solenoid valve bank all in one package
DME Valve Gate Controller Products and Solutions
|
Valve Gate Controls

PROGRAMMABLE TRIGGERS & ALARMS


• Digital input – sequence start trigger
• Digital input triggers – programmable sequence triggers
• (2) Analog inputs 0-10 volts
• Analog input 4-20ma
• Remote enable signal – from IMM
• Fault relay output (dry contact) – to IMM
• Dry contact or 24VDC input triggering

Controller includes 15ft (4.8m) solenoid power cord


U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net
Valve Gate Controls 161

VCAP Air Valve Assemblies and 4-Zone Timer

VCAP multi-station air valve assemblies


The VCAP series offers 4-station (0400), 6-station (0600), 8-station (0800),
10-station (1000), and 12-station (1200) valve assemblies. The single-solenoid
valves are spring returned and designed to run from 24 VDC +/- 10%. The air
supply (maximum rated pressure 145 PSI) can be lubricated or non-lubricated
– dry air is preferred but the valve is designed to tolerate some moisture.

Quick connects are provided on all air outputs to accept standard 1/4" tubing.
The de-energized outputs, used for closing valve gates, feature check valves
to ensure that unused valves do not leak air.

item number description


vcap0400 4-station air valve assembly

Valve Gate Controls


vcap0600 6-station air valve assembly
vcap0800 8-station air valve assembly
vcap1000 10-station air valve assembly
vcap1200 12-station air valve assembly

Note: E
 ach valve assembly includes a valve cable.

|
VCAP Air Valve Assemblies and 4-Zone Timer
Compact 4-zone pneumatic or hydraulic control unit
The VCTB4000 Valve Gate Controller is designed to provide timer-based control
of up to four 24 volt DC valves used to actuate pneumatic valve gate cylinders as
well as some hydraulic valves, and features a user-friendly auto-reset feature. Its
compact size makes it extremely portable and requires minimal space. A single
DB025 cable connects the controller to up to four remotely located valves,
minimizing wiring and air connections.

item number description


vctb4000 4-zone pneumatic Highly accurate DME
hydraulic controller
vcpt0100 100-ft. length of solid state timers
pneumatic tubing

Note: T
 rigger signal cable included with controller.
feature resolution to
1/100 of a second, far
exceeding the industry
standard of 1/10 of
a second.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


162 Valve Gate Controls

DME Single Zone Timer

DME Single Zone Timer: TCM03024D

Versatile for virtually any type of operation that requires a timer, including single-zone valve gate systems, core
pulls, and air sweeps.

 Unit plugs directly into DME Smart Series Mainframes Trigger input signal can be ganged to operate more than

one timer when multiple units are used (24 VDC input only)
 Test button (green light indicates power out)
Input signal and output power can be used from timer

 Yellow light indicates trigger signal being applied
front panel connectors or DME mainframe cables
or timer in operation
Thermocouple cable serves as trigger signal; power

 Trigger signal has two available sources – dry set of
cable serves as 24 VDC power supply to any 24 VDC
contacts or 24 VDC input
solenoid valve
DME Single Zone Timer

DME Single Zone Timers (TCM03024D)


|

are highly accurate, solid state timers


Valve Gate Controls

that feature resolution to 1/100 of second,


far exceeding the industry standard of
1/10 of a second.

Shown next to a SSM1512 Temperature Controller in a Standard 2-Zone


Smart Series Mainframe.

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


Control Systems 163

Technical Support

Customer Power Requirement Worksheet – Option A Delta 3-Phase Power 240 VAC
It is the customer’s responsibility to make sure his Hot Runner Mold Application will not exceed the power limitations of the
DME Hot Runner Control System Main Circuit Breaker. Even though each slot may be rated at 15 amps, all slots CANNOT
necessarily deliver full power from all zones simultaneously.
PHASE A POWER PHASE B POWER PHASE C POWER
ZONE # WATTAGE ZONE # WATTAGE ZONE # WATTAGE
1 2 3
4 5 6
7 8 9
10 11 12
13 14 15
16 17 18
19 20 21
22 23 24
25 26 27
28 29 30
31 32 33
34 35 36
37 38 39

Control Systems
40 41 42
43 44 45
46 47 48
49 50 51
52 53 54
55 56 57
58 59 60

|
TOTAL PHASE A WATTS TOTAL PHASE B WATTS TOTAL PHASE C WATTS

Technical Support
Record Product Breaker Record Product Breaker Record Product
Size Phase Wattage Not Size Phase Wattage Not Breaker Size Phase
To Exceed To Exceed Wattage Not To Exceed

Breaker Wattage Size Table – For Delta 240 VAC 3-Phase Power
MAXIMUM PHASE WATTS MAXIMUM PHASE AMPS
BREAKER RATING AMPS EACH PHASE A,B,C EACH PHASE A,B,C
CANNOT EXCEED THIS VALUE CANNOT EXCEED THIS VALUE
10 AMP 1,386 WATTS 5.77 AMPS
20 AMP 2,771 WATTS 11.55 AMPS
30 AMP 4,157 WATTS 17.32 AMPS
40 AMP 5,542 WATTS 23.09 AMPS
50 AMP 6,928 WATTS 28.87 AMPS
63 AMP 8,729 WATTS 36.27 AMPS
70 AMP 9,699 WATTS 40.41 AMPS
100 AMP 13,856 WATTS 57.74 AMPS

For 3 Phase Delta Power: TOTAL WATTS = SquareRoot (3) x VoltsAC x AMPS
MAXIMUM PHASE WATTS = TOTAL WATTS / 3

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net


164 Control Systems

Technical Support

Technical Support: RETURNING ITEMS TO DME


Return for Repair

U.S. Customers:
TSP, TSP Plus, TSP-SVG Systems and TSM modules needing repair or calibration:
 Please call 800-626-6653 for a Repair SR#. Please make sure
the SR# is on the outside of the box to expedite the repair.
DME Company
29111 Stephenson Highway
Madison Heights, MI 48071
Attention Repairs
All other temperature controls needing repairs send to:
DME Repairs
1419 State Route 45 South
Austinburg, OH 44101

Canadian Customers:
 DME Company
6210 Northwest Dr.
Mississauga, ONT L4V1J6
| blankSupport

Attention Repairs

Call 800-387-6600 if you need additional help.
| Technical

Please enclose contact information and a description of what problems you have been experiencing with the product.
This procedure includes items still under warranty, however fuses and triacs are not covered.
Systems
Systems

Return for Credit


Control

Call DME USA at 800-626-6653 or DME Canada at 800-387-6600 toll free


Control

U.S. 800-626-6653  Canada 800-387-6600  [email protected]  www.dme.net