Footing Design
Footing Design
COLUMN
Length (l, dim. || Z axis ) = 300 mm
global
Breadth (b, dim. || X axis) = 300 mm
X
Breadth 1.52 m
FOOTING
Foot length (L, dim. || Z axis) = 1.52 m
global global
Foot Breadth (B, dim. || X axis) = 1.52 m
Z Z
Thickness of footing (t) = 300 mm
Clear cover of footing = 50 mm
global
Main bar dia of footing = 12 mm
Effective depth of footing dz = 244 mm Length 1.52 m
Effective depth of footing dx = 232 mm
Selfweight of the footing = 17.33 KN Footing Dimensions
Area of Footing(A) = 2.31 m2
Sect mod of foot about Z axis (Zz) = 0.59 m3
Sec mod of foot about X axis (Zx) = 0.59 m3
MATERIALS OF CONSTRUCTION
2
Grade of concrete fck = 20 N/mm
2
Grade of steel fy = 415 N/mm
DESIGN FORCES
Factored load comb. no. 2
Axial load:(Pu) = 442 KN
Moment about Z axis (Muz) = 9 KN-m
Moment about X axis (Mux) = 9 KN-m
Maximum effective soil pressure pe max
2
( Pu/Area+ Muz/Zz + Mux/Zx) = 222.06 KN/m
Minimum effective soil pressure pe min
2
( Pu/Area - Muz/Zz - Mux/Zx) = 160.56 KN/m
Design of footing is done using above maximum effective soil pressure
CALCULATION FOR BOTTOM STEEL
Mu about X1 X1 = ( pe max x length2/2)= 41.31 KN-m per meter
Mulimit = 164.44 KN-m per meter
0.5 f ck é 4 .6 M u ù
Ast = ê1 - 1 - ú bd The section is singly reinforced
fy êë f ck bd 2 úû
2
Hence, Ast = 489.591 mm
2
Min Ast = 360.000 mm (0.12 % for slab, cl 26.5.2.1)
Spacing (reqd.) = 231.00 mm (considering max of above two calculated values of Ast)
pt required = 0.20 % Sp (prov.) = 150 mm Ast (prov.) = 753.98
Hence required 12 mm dia bar @ 231 mm c/c parellel to length of footing ( || to Z) mm2
pt (prov.) = 0.31 %
Mu about N1 N1 = ( pe max x length2/2)= 41.31 KN-m per meter
2
Calc. Ast = 517.421 mm The section is singly reinforced
2
Min Ast = 360 mm (0.12 % for slab, cl 26.5.2.1)
Spacing (reqd.) = 218.58 mm (considering max of above two calculated values of Ast)
pt required = 0.21 % Sp (prov.) = 150 mm Ast (prov.) = 753.98
Hence required 12 mm dia bar @ 218 mm c/c parellel to breadth of footing ( || to X) mm2
Arrangement of bottom reinforcement as per above design is shown below
pt (prov.) = 0.32 %
12 mm dia bar @ 150 mm c/c
1 1
Sec 1-1
544 300
544
L1 X1 X
a a
Z Z
N1 N1
a a
L2 L2
366 X1 X
L1 Breadth 1520 mm
300
Footing Length 1520 mm 366
PLAN
CHECK FOR ONE WAY SHEAR :
2 8 100.531 -576.82
2 8 100.531 -576.82
2 8 100.531 -576.82
2 8 100.531 -576.82
2 8 100.531 -576.82