Mcpa-Kac Data Sheet

The MCPA-KAC is an addressable manual call point compatible with GFE control panels. It has an enhanced communication mechanism that provides an alarm response time of approximately one second. The call point has an address set via an 8-way DIL switch and a bi-color LED that flashes green during interrogation and lights red during an alarm. It can be surface or flush mounted and easily reset with a key after activation.

Uploaded by

Adrian Oprisan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views2 pages

Mcpa-Kac Data Sheet

The MCPA-KAC is an addressable manual call point compatible with GFE control panels. It has an enhanced communication mechanism that provides an alarm response time of approximately one second. The call point has an address set via an 8-way DIL switch and a bi-color LED that flashes green during interrogation and lights red during an alarm. It can be surface or flush mounted and easily reset with a key after activation.

Uploaded by

Adrian Oprisan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MCPA-KAC

Addressable Manual Call Point

The MCPA-KAC is an Analogue Addressable Manual


Call Point, designed and manufactured to comply with
EN-54 part 11, compatible with all GFE Addressable
Control panels.

With its enhanced communications mechanism the


typical response time, when in alarm, is approximately one second, depending on the number of
call points connected to the device loop.

A bi-colour LED flashes Green when the unit is interrogated by the control panel and is illuminated
Red when in Alarm. The command to illuminate the Red LED is emitted by the control panel in
response to activation of the individual call point thus confirming that the Alarm signal has been
received at the control panel. The individual address, up to 125, of each call point is set via an eight
way DIL switch.

This unit can be both surface and flush mounted and it can be easily reset using the supplied key
after activation.Optionally it can be supplied complete with a hinged flap which protects the
trigger element from accidental activation and reduces malicious activations as two actions are
required in order to activate the device.

Mechanical Specification Switches 1-7


Used to configure the Manual Call Point
Address
72.0
89.0 59.5 60.0
Switch 8
Not used

ON (1)
93.0

72.0

OFF (0)
1 2 3 4 5 6 7 8
Address Switches binary weights
1 on =1 4 on =8 7 on = 64
2 on =2 5 on =16
3 on =4 6 on =32

Technical Specifications
Supply Voltage Loop Powered 17-30 V DC
Current - Quiescent 500 uA
Current - Device in Alarm 3.5 mA - Alarm LED Illuminated
2
Max. Cable Size 0.5-2.5 mm
Max. Recommended per Loop 30
Colour/ Case Material/ Protection Red / ABS Flame Retardant 94V0/ IP24
Oper. Temperature/ Max. Humidity 0 ºC to 50 ºC/ 95% RH Non-Condensing
Dimensions/ Weight 93.0 (H) x 89.0 (W) x 59.5 (D) mm/ 160 grams
Order Code
MCPA-KAC KAC Addressable Manual Call Point