It On User Manual
It On User Manual
ITON
-
Introduction
This UPS is specially designed for Personal Computer
with multi-functions. Its light weight, compact design
perfect fits to the limited working environment. The line of
UPS is equipped with boost and buck AVR to stabilize
input voltage range. It is also built-in with DC start
function. This function enables the UPS to be started up
without AC power supplied. Although it's a small UPS, it's
equipped with Smart RS-232 Communication Port to offer
users more benefits. The download software helps users
monitor UPS inside status. The main features of the UPS
are listed below:
-
Installation and Operation
Installing the UPS is as easy as following the steps
shown. Be aware of the power Switch must be kept in
the “ON” position, otherwise, the UPS will be
disabled and your equipment will not be protected
during a power failure.
Inspection
1 Remove the UPS from its package and inspect
it for damage that may have occurred during
shipping. If any damage is discovered, re-pack
the unit and return it to the place of purchase.
Placement
2 Install the UPS unit in any protected
environment that provides adequate airflow
around the unit, and is free from excessive
dust, corrosive fumes and conductive
contaminants. Do not operate your UPS in an
environment where the ambient temperature or
humidity is high.
X
On the other hand, place the UPS unit away from the
monitor at least 20cm to avoid interference.
20 cm
Charging
3 This unit is shipped from the factory with its
internal battery fully charged, however, some
charge may be lost during shipping and the
battery should be recharged prior to use. Plug
the unit into an appropriate power supply and
allow the UPS to charge fully by leaving it
plugged in for at least 8 hours.
¾ 8 hours
Computer Connection
4 Connect one computer-related device into
each of the power receptacles supplied on the
back of the UPS.
Modem / Phoneline Connection
5 Plug incoming internet line into the “In” socket at
the back of the UPS. Use one more Internet line
cable and plug one end of the Internet line cable
to the “Out” socket at the back of the UPS. Plug
the other end of the modem input socket as
shown below.
Incoming
Internet line
DC Start Function
8 DC Start Function enables UPS to be started
up when AC utility power is not available and
battery is fully charged. Just simply press the
power switch to turn on the UPS.
-
UPS Monitoring Software
– WinPower –
Every unit is bundled with UPS monitoring software -
WinPower. This is a unique uninterruptible power supply
(UPS) control software that offers you unprecedented
convenience for the control of any UPS.
Features:
u Saves files before shutdown occurs
u Scheduled system shutdown
u Graphic display of UPS status
u Warning notification via E-mail
u User-friendly interface
u Multi-language versions
+
-
System Description
Front panel –
1
1. Power Switch
LED Indicators
AC Mode: Green LED on
Battery Mode: Green LED flashing
Back Panel --
1. Output receptacles
2. AC Input
3. Modem / Phoneline Surge Protection
4. Communication Port
5. Circuit Breaker
4
3
2
1 5
+
-
Specification
-
Trouble Shooting
-
INSTRUCTION
SAVE THESE INSTRUCTION-This manual contains important
instructions for model
ITON 600 Plus that should be followed during installation
and maintenance of the UPS and batteries.
Safety -- Caution!!
u This UPS utilize voltage that may be hazardous. Do not
attempt to disassemble the unit. The unit contains no
user replaceable parts. Only factory service personnel
may perform repairs.
u Internal battery voltage for ITON 600 is 12Vdc and for
ITON 1000 is 24Vdc.
u Connection to any other type of receptacle other than a
two-pole, three-wire grounded receptacle may result in
shock hazard as well as violate local electrical codes.
u In the event of an emergency, press the “OFF” button and
disconnect the power cord from the AC power supply to
properly disable the UPS.
u Do not allow any liquids or any foreign object to enter the
UPS. Do not place beverages or any other liquid-
containing vessels on or near the unit.
u This unit intended for installation in a controlled
environment (temperature controlled, indoor area free of
conductive contaminants). Avoid installing the UPS in
locations where there is standing or running water, or
excessive humidity.
u Do not plug the UPS input into its own output.
u Do not attach a power strip or surge suppressor to the
UPS.
u Do not attach non-computer-related items, such as
medical equipment, life-support equipment, microwave
ovens, or vacuum cleaners to UPS.
u To reduce the risk of overheating the UPS, do not cover
the UPS' cooling vents and avoid exposing the unit to
direct sunlight or installing the unit near heat emitting
appliances such as space heater or furnaces.
u Unplug the UPS prior to cleaning and do not use liquid or
spray detergent.
Safety – Caution!!
u Do not dispose of batteries in a fire as they may
explode.
u Do not open or mutilate the battery or batteries.
Release electrolyte is harmful to the skin and eyes. It
may be toxic.
u A battery can present a risk of electrical shock and
high short circuit current. The following precautions
should be observed when working on batteries:
1) Remove watches, rings, or other metal objects
from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting
or disconnecting batteries terminal.
u Servicing of batteries should be performed or
supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized
personnel away from batteries.
u When replacing batteries, replace with the same
number and type of sealed lead-acid battery.