Data input for pressure referenced anomaly calculations for a single corrosion pit represented by length, L, and depth, d. The data must be
‘entered in the shaded areas in SI units only. The appropriate conversions are shown to the right of the entered data.
Line Name: Rainbow Cadotte-EVI NPS 20”
Dig #: Dig RGW 1950
Wheelcount (m): 2134.53
Log Year 2007
Pipe Specifications:
SI Units English Units
D (mm) = [J 508 "outside diameter 20 inches
t(mm) = 7.40 nominal wall thickness 0.291
SMYS (MPa) = _ 359 _ specified minimum yield strength 52068 psi
MAOP (kPa) = 7260.00 maximum allowable operating pressure 1052.97 _psi
Class Factor= 0.72
Temperature Factor= 1
Defect Information:
Lm 140979) measured length of corroded area 551 inches
d(mm)= 4.97 _ maximum depth of corroded area 0.078 inches
Depth (%)= 27% 27%
The greater of Piesg, or MAOP = 7530.52 kPa
B31G Maximum Allowable Length = 108.00 mm EXCEEDS ALLOWABLE LENGTH
B31G Safe Maximum Pressure = 7391.01 kPa
B31G Factor of Safetly= 0.98
0.85dL Area Safe Maximum Pressure = 7809.88 kPa
O.85dL Area Factor of Safely= 1.04
‘Additional Comments = DEFECT EXCEEDS 100mm IN LENGTH
Pipe Grade Table
Pipe Grade] SMYS (MPa) | SMYS (psi)
25 172 25000
A 207 ‘30000
B 241 '35000
Kaz 288 42000
X46 317 46000
X52, 358 52000
X56 386 56000
X60 a3 ‘60000
X65) 448 ‘65000
X70 482, "70000
X80 551 ‘30000
Conversion Charts
1 0.3048[m
1 = 25.4[mm,
1 = 5280|ft
1 = 7,6093]km
“[psi__= 6.8948|kKPa
a|MPa_= +1000]kPa
ENGINEERING ASSESSMENT REQUIRED
ACCEPTABLE, VERIFY WITH ENGINEERING1.0 ASME B31G-1991
1.1 Calculation of the Maximum Allowable Length of a Corroded Area
1.57 Caleulated factor, equal to 4 for dit < 0.175
Lom 108.00 Maximum Allowable Length of the Corroded Area
Evaluation: UNACCEPTABLE
1.2 Calculation of the Maximum Allowable Operating Pressure in Corroded Areas
2.0391
7530.52 Design Pressure
0.72 Class Factor
1 Temperature Factor
7530.52 ‘The greater of the established MAOP or P
7391.01 The safe maximum pressure for the corroded area.
0.98
Evaluation: ACCEPTABLE2.0 Calculation of the Remaining Strength of Corroded Pipe
2.1 Case 2 - Modified B31G Criterion - 0.85dL Area
Folias Factor Constant 521
Folias Facto 2.04
Pa (kPa! 7530.52 Design Pressure
Fe 0.72 Class Factor
Ts 1 ‘Temperature Factor
P(kPa)= 7530.52 ‘The greater of the established MAOP or P
Presa (kPa) = 7809.88 The safe maximum pressure for the corroded area,
Proust oasa (KPa) = 10847.08 Predicted burst pressure for the corroded area.
0.85dL RPR 1.04
Evaluation: ACCEPTABLE