CASE 2901: Inquiry: Under What Requirements May External Loads (Forces and Bending Moments) Be Evaluated For

This document summarizes the requirements for evaluating external loads on welding neck flanges chosen according to Section VIII of the ASME Boiler and Pressure Vessel Code. The external loads, including forces and bending moments, can be evaluated using the following conditions: (1) the actual assembly bolt load must comply with PCC-1 Appendix O, (2) the bolt material strength must exceed the specified bolt size, and (3) the combination of flange pressure and external loads must satisfy the provided equation. The external load evaluation must also meet requirements for consistent units, documentation on reports, and flange material standards.

Uploaded by

Dijin Maroli
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
736 views

CASE 2901: Inquiry: Under What Requirements May External Loads (Forces and Bending Moments) Be Evaluated For

This document summarizes the requirements for evaluating external loads on welding neck flanges chosen according to Section VIII of the ASME Boiler and Pressure Vessel Code. The external loads, including forces and bending moments, can be evaluated using the following conditions: (1) the actual assembly bolt load must comply with PCC-1 Appendix O, (2) the bolt material strength must exceed the specified bolt size, and (3) the combination of flange pressure and external loads must satisfy the provided equation. The external load evaluation must also meet requirements for consistent units, documentation on reports, and flange material standards.

Uploaded by

Dijin Maroli
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CASE 2901

Case 2901

Evaluation of External Loads on Welding Neck Flanges Covered by UG-44(b), (i), and (j) of Section VIII,
Division 1, or 4.1.11.1(a) and (g), and 4.1.11.3 of Section VIII, Division 2, Class 1 and Class 2.

Inquiry: Under what requirements may external loads (forces and bending moments) be evaluated for
welding neck flanges chosen in accordance with UG-44(b), (i), and (j) of Section VIII, Division 1, or 4.1.11.1(a)
and (g) and 4.1.11.3 of Section VIII, Division 2, Class 1 and Class 2?

Reply: It is the opinion of the Committee that external loads (forces and bending moments) may be
evaluated for welding neck flanges chosen in accordance with UG-44(b), (i), and (j) of Section VIII, Division 1,
or 4.1.11.1 (a) and (g), and 4.1.11.3 of Section VIII, Division 2, using the following requirements

(a) The actual assembly bolt load (see Appendix S of Section VIII, Division 1 and 4.11.16 of Section VIII,
Division 2) shall comply with ASME PCC-1, Appendix O.
(b) The bolt material is SA-193 B8 Cl. 2 or has a higher allowable stress at the specified bolt size
(c) The combination of flange design pressure with external moment and external axial tensile force shall
satisfy eq. (1)

16𝑀𝑀𝐸𝐸 + 4𝐹𝐹𝐸𝐸 𝐺𝐺 ≤ 𝜋𝜋𝐺𝐺 3 �(𝑃𝑃𝑅𝑅 − 𝑃𝑃𝐷𝐷 ) + 𝐹𝐹𝑀𝑀 𝑃𝑃𝑅𝑅 � (1)

(d) The units of the variables in Equation (1) shall be consistent with the pressure rating
(e) This Code Case shall be recorded on the Manufacturer’s Data Report (UG-120 of Section VIII, Division
1) or Manufacturer’s Design Report (2.3.3 of Section VIII, Division 2)
(f) Nomenclature

ME = External moment
FE = External tensile axial force
G = Gasket reaction diameter (see 2-3 of Section VIII, Division 1 and 4.16.12 of Section VIII, Division 2)
PR = Flange pressure rating at design temperature
PD = Flange design pressure at design temperature
FM = Moment factor, in accordance with Table 1
TABLE 1
MOMENT FACTOR, FM
Flange Pressure Class
Standard (Note 5) Size Range 150 300 600 900 1500 2500
ASME B16.5 ≤ NPS 12 1.2 0.5 0.5 0.5 0.5 0.5
ASME B16.5 > NPS 12 and ≤ NPS 24 1.2 0.5 0.5 0.3 0.3 -
ASME B16.47 Series A ALL 0.6 0.1 0.1 0.1 - -
ASME B16.47 Series B < NPS 48 Note 1 Note 1 0.13 0.13 - -
ASME B16.47 Series B ≥ NPS 48 0.1 Note 2 - - - -
Notes:
1. 𝐹𝐹𝑀𝑀 = 0.1 + (48 − 𝑁𝑁𝑁𝑁𝑁𝑁)⁄56
2. 𝐹𝐹𝑀𝑀 = 0.1 except NPS 60, Class 300, in which case 𝐹𝐹𝑀𝑀 = 0.03
3. The combinations of Size Ranges and Flange Pressure Classes for which Table 1 gives no moment
factor value, are outside the scope of this Code Case.
4. The designer should consider reducing the allowable factor if the loading is primarily sustained
in nature and the bolted flange joint operates at a temperature where gasket creep/relaxation
will be significant (typically above 450°F (232°C) metal temperature).
5. The acceptable edition of the Standard shall be as shown in Table U-3 for Section VIII, Division 1
construction and Table 1.1 for Section VIII, Division 2 construction.