Excel Based
Excel Based
Problem 1
Given:
Required:
If feed enters at (a) 25 0C, (b) at its boiling temperature and (c) 100 0C, determine
Solution:
a. AT 25OC
1. Open the excel and draw the 45o line and equilibrium curve
𝑞 = 1.336263
3. And draw the operating line using the obtained q-value touching the equilibrium curve. The
equation of the:
q x
y x- f
q -1 q -1
1.33626
y x - 0.4
1.33626- 1 1.33626- 1
y = 3.9739x - 1.1895
1
0.9
VAPOR CONCENTRATION OF
0.8
0.7
BENZENE YA
y = 3.9739x - 1.1895
0.6
0.5
0.4
0.3
0.2
0.1
0
0 0.2 0.4 0.6 0.8 1
LIQUID CONCENTRATION OF BENZENE XA
3. Now draw the enriching line, connect the point (xD,yD) to (xA, yA) touching the equilibrium curve.
Show the equation of q-line and enriching line. Solve for their intersection using solver. Solve for the
𝑦2 −𝑦1
slope of enriching line which is mmin using the the coordinates of xd and intersection solved.
𝑥2 −𝑥1
𝑅𝑚𝑖𝑛
𝑚𝑚𝑖𝑛 =
𝑅𝑚𝑖𝑛 + 1
𝑦𝐷 −𝑦𝐴
𝑚𝑚𝑖𝑛 =
𝑥𝐷 −𝑥𝐴
𝑚𝑚𝑖𝑛
𝑅𝑚𝑖𝑛 =
1 − 𝑚𝑚𝑖𝑛
/g0
The xA and yA is the intersection of equilibrium curve and q-line, get the equation of the
equilibrium and q-line and solve for their intersection using solver. As for (xD, yD) = (0.98,0.98)
𝑦𝐷 −𝑦𝐴 0.98−0.6895500521
𝑚𝑚𝑖𝑛 = = =0.572725026
𝑥𝐷 −𝑥𝐴 0.98−0.472864
𝑚 0.572725026
𝑅𝑚𝑖𝑛 = 1−𝑚𝑚𝑖𝑛 =1−0.572725026=1.340411901
𝑚𝑖𝑛
Ractual xD
y x
Ractual 1 Ractual 1
y = 0.7283x + 0.2662
Hv=yAHAB + yBHBT
hl=xAhAB + xBhBT
30
25
20
ENTHALPY
15
10
5
y = 0.1215x5 + 0.441x4 - 2.7695x3 + 6.1395x2 - 3.9375x + 0.0183
0
0 0.2 0.4 0.6 0.8 1 1.2
-5
CONCENTRATION
The equations of the enthalpy of saturated liquid (hl) and of the enthalpy of saturated vapor (Hv) will
be of use in getting the Hv and hl at x= 0.98.
Now to plot the operating line, get the highet coordinates of the line (xD, y) where your y is:
QC
y hl Hv R ( Hv hl )
D
Use newly solved Hv and hl in solving the y then plot the operating line;
Through solver, obtain the Hv and hl values then plot the obtained values.
Graph of hl and Hv
0.957488 30.98065
0.98 113.8424
0.919409 31.10497
0.98 113.8424
0.861962 31.28009
0.98 113.8424
0.786908 31.49026
0.98 113.8424
0.704459 31.70253
0.98 113.8424
0.629319 31.88382
0.98 113.8424
0.544641 32.07887
0.02 -93.8354
0.438409 32.31542
0.02 -93.8354
0.324727 32.56362
0.02 -93.8354
0.221244 32.78691
0.02 -93.8354
0.139402 32.96095
0.02 -93.8354
0.081266 33.08215
0.02 -93.8354
0.042938 33.1604
0.02 -93.8354
0.01886 33.20871
0.02 -93.8354
0 0
0.02 -93.8354
150
100
50
ENTHALPY
0
0 0.2 0.4 0.6 0.8 1 1.2
-50
-100
-150
CONCENTRATION
150
100
50
ENTHALPY
0
0 0.2 0.4 0.6 0.8 1 1.2
-50
-100
-150 CONCENTRATION
x45line 0.02
Therefore, number of stages: 13
x45line xEq.line
0.0429 0.02
13
0.0429 0.0192
13.966
Condenser duty
W= 89 mol/s
QC (11)(113.5560 (0.03399))
Qc = 1249.49 KW
Reboiler duty
QR (hW R)W
QR (0.0581654 (93.597))89
QR = 8356.9963 KW
Repeating the same procedure, graph the phase equilibrium diagram then get the equations
1. The feed enters the distillation unit at its boiling point, which means it is in saturated liquid
condition. The the value of q at saturated liquid is 1, q=1.
2. Determination of Rmin.
0.6
0.4
0.2
0
0 0.2 0.4 0.6 0.8 1
Liquid concentration of benzene, xa
Taking the equation of the equilibrium curve, and substituting x with xD gives y coordinate of
q-line or the yA, while xA=xD= yD=0.4. Now that (xD, yD) and (yA, xA) is known, mmin is already
solvable which will be then used is solving Rmin. Solving for Rmin gives:
Rmin = 1.618652026
3. Plotting the enthalpy-concentration diagram and solving for the operating line.
Using solver, solve for the values of H_l line and H_v line.
35
30
25
20
ENTHALPY
15
10
5
0
0 0.2 0.4 0.6 0.8 1
-5
CONCENTRATION
0.98 131.0586424
0.98 0
0.956382602 30.98436262
0.98 131.0586424
0.914601855 31.12017414
0.98 130.8977203
0.848926253 31.31798643
0.98 131.0586424
0.760841466 31.55920034
0.98 131.0586424
0.663667167 31.80212087
0.98 131.0586424
0.576983627 32.0052661
0.98 131.0586424
0.486535848 32.20904388
0.02 -86.9864
0.381210786 32.44072213
0.02 -86.9864
0.275834264 32.66944368
0.02 -86.9864
0.184643763 32.86512025
0.02 -86.9864
0.114685807 33.01279223
0.02 -86.9864
0.065616183 33.11428716
0.02 -86.9864
0.033265982 33.17989441
0.02 -86.9864
0.012778131 33.22078726
0.02 -86.9864
150
100
50
ENTHALPY
0
0 0.2 0.4 0.6 0.8 1 1.2
-50
-100
CONCENTRATION
Plot the operating line, hl and Hv line and the number of stages.
150
100
50
0
0 0.2 0.4 0.6 0.8 1 1.2
-50
-100
Condenser duty
QC
hD D
D
QC D(D hD )
Qc = 1442.02 KW
Reboiler duty
QR
hW R
W
QR (hW R)W
QR = 7736.61 KW
c. AT 100°C
The same procedure graph the phase equilibrium diagram then get the equations
1. At 100oC and benzene concentration, xA=0.4, the feed condition falls in saturated mixture
region, based on temperature-concentration diagram. For this type of feed, the lever rule is
used to solved for q-value:
n vap c b
n liq b a
n vap
q
n vap n liq
q =0.709777
therefore, q is a fraction or partially vaporized
2. Determination of Rmin
1
VAPOR COMPOSITION OF BENZENE yA
0.8
0.6
0.2
0
0 0.2 0.4 0.6 0.8 1
LIQUID COMPOSITION OF BENZENE XA
Use the same process for solving Rmin based from the previous conditions, which then gives:
Rmin = 1.963152233
100
50
0
0 0.2 0.4 0.6 0.8 1 1.2
-50
-100
30
25
20
15
10
0
0 0.2 0.4 0.6 0.8 1 1.2
-5
0.98 152.3747817
0.98 0
0.955355936 30.98780374
0.98 152.3747817
0.909914977 31.13489354
0.98 152.3747817
0.835975364 31.35501921
0.98 152.3747817
0.73467294 31.62663439
0.98 152.3747817
0.622992087 31.89867996
0.98 152.3747817
0.525695387 32.12156908
0.98 152.3747817
0.332985059 32.54569576
0.02 -80.661
0.332985059 32.54569576
0.02 -80.661
0.237193453 32.75267744
0.02 -80.661
0.157012315 32.92377965
0.02 -80.661
0.096489084 33.05067274
0.02 -80.661
0.054161334 33.13765182
0.02 -80.661
0.026065874 33.19432807
0.02 -80.661
0.008049676 33.2301444
0.02 -80.661
200
150
ENTHALPY 100
50
0
0 0.2 0.4 0.6 0.8 1 1.2
-50
-100
CONCENTRATION
Plot the operating line, hl and Hv line and the number of stages.
200
150
100
ENTHALPY
50
0
0 0.2 0.4 0.6 0.8 1 1.2
-50
-100
CONCENTRATION
Condenser duty
QC
hD D
D
Reboiler duty
QR
hW R
W
QR = 7173.65 KW