Appendix A2
Appendix A2
2015 September
Table of Content
Food Labeling
GB 7718-2011
The standard replaces GB 7718-2004 General Principle for Prepackaged Food Label.
- Definitions for prepackaged food and production date were amended, definition for specifications
was added, while definition for shelf-life was removed;
- Amended the format for presentation of manufacturer name, distributor name and their
corresponding address and contact information;
- Amended the largest surface area for product packaging or container used when the length of fonts,
symbols and numbers used for indicating mandatory label contents is 1.8mm and above;
- Added the requirements on the format of presentation for the recommendation labels indicating
presence of potential allergens to consumers;
- Amended the calculation methodology used for computing largest surface area in Appendix A;
1. Scope
This standard applies to the labels of prepackaged food that are sold/distributed directly and indirectly to
the consumers.
This standard does not apply to the labels used on storage & transportation packaging dedicated towards
protecting prepackaged food products during storage and the transportation process, labels for bulk food
products and labels for food products made and sold on-site.
Refers to food that are prepackaged or manufactured in specified fixed amounts, with packaging materials
and/or within containers. These include food products consistent in quality and size, maintaining
discrepancies within a limited range specified, that are prepackaged and pre-manufactured with
packaging materials and/or within containers.
2.3 Ingredients
Refer to any substance that is present (including substances present in a modified manner) in the food,
added and used during food production and processing, including food additives.
Refers to the date when food is transformed into its final product format, i.e. the date that the food is
packaged or filled into the packaging or container, becoming the final product ready for sales/distribution
will constitute the date of production.
2.5 Shelf-life
Refers to the time period that the prepackaged food product maintains quality suitable for consumption,
when stored under the recommended storage conditions indicated on its label. Products are suitable for
sales/distribution within this stipulated period, and they possesses the unique characteristics that are not
required to be indicated explicitly or already indicated in the product labels.
2.6 Specifications
Refer to statements that indicate the net content and the number of smaller packages include in the bigger
packaging under the circumstance that the product packaging contains multiple smaller packaging within.
Refers to the panel for labels that is positioned on prepackaged food product packaging or container in an
easily observable manner.
3. Basic Requirements
3.1 The label should comply with the provisions of laws and regulations as well as the requirements of
corresponding food safety standards.
3.2 The label should be clear, eye-catching, durable, and easy for the consumers to identify and read
during the purchasing process.
3.3 The label should be plain, easy to understand, and its content should be scientifically supported. The
label should not contain any superstitious, erotic content nor make any attempt to play down on other food
products or display any content contrary to general knowledge on nutritional science.
3.4 The label content should be factual and accurate, where false and exaggerated claims should not be
used. The label should not contain any deceptive or easily misunderstood messages in manners such as
words, patterns, to describe the food products to the consumers. It should not leverage on size difference
or color contrasts of fonts to mislead consumers as well.
3.5 The label should not mislead consumers into confusing product or certain aspect of a product that
they intend to buy with another product, with the use of direct or suggestive language, words, patterns and
symbols.
3.6 The label content should not indicate or suggest that the product has the ability to prevent or cure
diseases. Non-health food product label should not indicate or suggest that the product has specific health
boosting effect.
3.7 The label should not be separated from the food or its product packaging (container).
3.8 The label should use standard Chinese characters (with the exception of its trademark). Any wordart
used meant for decorative purposes should be properly inscribed and easily identifiable.
3.8.1 Pinyin (phonetic illustration of Chinese characters) or characters used by ethnic minorities can be
used with Chinese characters, but pinyin used should be smaller than the corresponding Chinese
characters used in the label.
3.8.2 3.8.2 Foreign language can be used, but foreign language used must have corresponding
relationship with the Chinese characters on the label (with the exception of trademark, name and address
of manufacturer of imported food, name and address of foreign distributor, webpage address.) All foreign
characters used should be smaller than the corresponding Chinese characters used in the label.
3.9 The length of character, symbol and number used in the mandatory label contents should not be less
than 1.8mm when the largest surface area (see Appendix A for the calculation methodology for computing
largest surface area) of prepackaged food packaging or container is larger than 35 cm2.
3.10 Under the circumstances that the packaging of a single sales unit contains multiple smaller
individual packages of products of multiple varieties that can be sold independently, separate food labels
should be included for each of the smaller individual packages.
4. Label Content
Food label of prepackaged food directly supplied to consumers should include required contents such as
food name, ingredient lists, net content and specifications, name, address and contact information of
manufacturer and (or) distributor, date of production, shelf-life, storage conditions, serial number of license
for food production, product standards code.
4.1.2.1 Dedicated term that clearly represent and reflect the true characteristics of the food product should
be placed at a striking position on the food label.
4.1.2.1.1 Under the circumstances that national, commercial or local standards had designated one or
multiple names as dedicated name(s) for a specific food product, one of these names or its equivalent
should be used.
4.1.2.1.2 Common or popular names that do not cause any misunderstanding nor confusion for consumers
should be used under the scenario that the choice of name of such products are not regulation by national,
commercial or local standards.
4.1.2.2 Names with format specified in 4.1.2.1 should be included on the same main display panel with the
displayed name, if one of the following types of displayed names is used: completely new and unknown
names, strange/unique names, transliterated names, branded names, names based on regional slang and
trademarked names.
4.1.2.2.1 Dedicated name that reflects the true nature of the food product should be shown with the same
font as and at a position on the main display panel neighboring the displayed name, when the displayed
name – in the form of a completely new and unknown name, strange/unique name, transliterated name,
branded name, name based on regional slang or trademarked name, uses words or jargons (phrases) that
potentially cause confusion for people.
4.1.2.2.2 Consistent font and color should be used for displayed name to reflect the true nature of the food
product, when inconsistent fonts or colors cause people to misunderstand the true nature of food products
despite the displayed name actually truly reflect the nature itself.
4.1.2.3 Corresponding words or phrases can be added before or after the dedicated food name for the
purpose of preventing misunderstanding or confusion of the true nature, physical state or manufactured
methodology of the food product. Examples include terms like “dried”, “concentrated”, “reconstituted”,
“smoked”, “fried”, “powdered”, “grain”, etc.
4.1.3.1 A list of ingredients should be shown on the prepackaged food product label, where each ingredient
listed in the list of ingredients should be labeled in accordance with the requirements of 4.1.2, while food
additives should be labeled in accordance with the requirements of 4.1.3.1.4.
4.1.3.1.1 “Ingredients” or “List of Ingredients” (in Chinese) should be used as term of guidance to lead
consumer to the actual list of ingredients. When all the raw ingredients used in the processing have changed
into other ingredients (in the case of fermented products, e.g. alcohols, soya sauce, edible vinegar), “Raw
Ingredients” or “Raw and Supplementary Ingredients” can replace “Ingredients”, “List of Ingredients” as
terms of guidance, while complying with the requirements of the corresponding clauses in this standard in
labeling the individual raw, supplementary ingredients and food additives. Processing aids are not required
to be explicitly listed in the list of ingredients.
4.1.3.1.2 Ingredients should be listed item-by-item in a descending order based on the individual amount
added in the product’s manufacturing or processing procedure; ingredients that do not constitute more than
2% of the total product composition can be listed in a random format without following a typical descending
order required for other ingredients.
4.1.3.1.3 Compound ingredient made up of 2 or more base ingredients (not inclusive of food additives)
should be listed in the list of ingredients with the specific name of the compound ingredient, with its base
ingredients listed within parentheses thereafter in descending order based on the amount added. Under the
circumstance that the compound ingredient is regulated by national, commercial or local standards and at
the same time, it constitutes less than 25% of the total product composition, the act of listing its base
ingredients is not required.
4.1.3.1.4 Food additives should be labeled with the specific common name stipulated in the standard GB
2760. Food additives can be labeled either in the format of only its specific name, or in the format of its
functional category along with its specific name or International Numbering System (INS) code (See
Appendix B for label formats.) One of the label formats shown in Appendix B should be chosen to label food
additives on the same prepackaged food label. Under the circumstance that a certain food additive does not
have a corresponding INS code or due to labeling requirements for allergens, specific name should be used
in favor of INS code along with the food additive’s functional category when the functional category format
abovementioned is adopted. Name of food additive does not include its method of production. Food additive
used in any compound ingredient constituting less than 25% of total product composition, need not be listed
if it fulfills GB 2760’s inductive principle and does not have any impact on the processing of the final product.
4.1.3.1.5 Any water added during food’s manufacturing or processing procedure should be labeled in the list
of ingredients. Water or any other ingredients that evaporated during the processing procedure need not be
listed.
4.1.3.1.6 Edible packaging or wrapping should also have its raw ingredients listed in the list of ingredients,
unless otherwise specified in any other national laws or regulations.
4.1.4.1 If the food label or food manual specially emphasized that the food is supplemented with or the food
contains one or more types of valuable, unique ingredients or components, the amount added or the specific
content composition of the emphasized ingredient or component should be indicated clearly on the list of
ingredients.
4.1.4.2 If the food label or food manual specially emphasized that the composition of one or more types of
ingredients or components is relatively low or insignificant (i.e. zero), the specific composition of the
emphasized ingredient or component should be indicated clearly on the list of ingredients.
4.1.4.3 Any food ingredient or component that is mentioned in the food name and at the same time not
specially emphasized on the on the corresponding food label, need not have the amount added or its
composition labeled on the list of ingredients.
4.1.5.1 Representation of net content should be made up of the net content value, numbers and its
authorized unit of measurement (See Appendix C for reference of format of representation.)
4.1.5.2 Net content of products bundled in packaging (container) should be represented in the following
format, according to its authorized unit of measurement:
a) Liquid food, use volume units of measurement, such as L or l, mL or ml, or use weight units of
measurement such as g or kg
c) Semi-solid food or food of sticky nature, use weight units of measurement such as g or kg, or use
volume units of measurement such as L or l, mL or ml
Table 2 Formats of Representation for Unit of Measurement Used for Net Content
Measurement Format Range of Net Content Value (Q) Unit of Measurement
Q < 1,000mL mL, ml
Volume
Q ≥ 1,000mL L, l
Q < 1,000g g
Weight
Q ≥ 1,000g kg
4.1.5.4 Minimum length of fonts used for representation of net content should comply with the requirements
listed in Table 3.
4.1.5.5 Net content information should be positioned on the same display panel of the product packaging or
container as its food name information.
4.1.5.6 If packaging container contains food substances in both liquid and solid states and the solid food
substance within constitute the product’s main ingredient, content of the food drained of liquid (i.e. the solid
food substance) should be represented in mass or mass proportion format on top of the net content
information (See Appendix C for reference of format of representation.)
4.1.5.7 Product specifications should be labeled along with net content information on the larger product
packaging when such larger packaging format contains multiple smaller individual prepackaged food
products.
4.1.5.8 Product specifications should be made of net content information and quantity of the individual
prepackaged food products within the larger packaging, or in the format of just the quantity of smaller
packages. “Specifications” need not be shown when presenting product specifications information.
Specifications information of individual prepackaged food products is equivalent to the net content of the
individual packages (See Appendix C for reference of format of representation.)
4.1.6.1 Name, address and contact information of manufacturer should be presented on the food label.
Name and address information of the manufacturer should be the name and address that are legally
registered and can be held responsible for the manufacturer’s product safety quality standards. Such
information should be presented in a format according to the specific requirements under the following
scenarios.
4.1.6.1.1 Manufacturer with its independent legal personality, i.e. a group of companies or subsidiary of a
group, should use its corresponding name and address on the product label.
4.1.6.1.3 If the processing for the prepackaged food products is subcontracted to another party, name and
address of both sides of the subcontracted process should be indicated; or simply indicating the name and
address of the party subcontracting the process out, along with the production location will suffice, of which
the production location should be presented in accordance with the administrative zone guidelines, up to the
level of the municipality regions.
4.1.6.2 Contact information listed for manufacturer/distributor that has an independent legal personality
should include at least one of the following content: telephone number, fax number, Internet contact
information and their likes, or mailing address listed together with the registered address.
4.1.6.3 Imported prepackaged food products should be labeled with the country or region of origin (e.g.
Hong Kong, Macau, Taiwan), and the name, address and contact information of the agent, importer and
distributor that are properly registered in China according to relevant laws and regulations. Name, address
and contact information of the manufacturer need not be indicated for import food products.
4.1.7.1 Date of production and period of shelf-life of prepackaged food products should be clearly indicated.
If “please see certain part of package for …” format is used for presentation of dates, the date information
should be positioned at the specific position mentioned. Date labels should not be separately covered over
by another label, reprinted or tampered with (See Appendix C for reference of format of representation.)
4.1.7.2 When a single prepackaged product contains individual smaller prepackaged food products with
individual date of production and shelf-life date labels, the earliest expiration date of all the individual
packages should be adopted on the outer packaging. The earliest date of production of individual packages
or the date when the outer package becomes a typical sales unit (i.e. all individual packages have been
packaged into the outer package, ready for sale) will be adopted as the date of production labeled on the
outer package; individual packages’ date of production and shelf-life can also be labeled separately on the
outer packaging.
4.1.7.3 Date should be presented in the year, month, day order. If the presentation format does not follow the
former date order, the specific date order used should be indicated as well (See Appendix C for reference of
format of representation.)
Prepackaged food product label should include storage conditions (See Appendix C for reference of format
of representation.)
Food production license number should be indicated on the prepackaged food product label according to
format stipulated in relevant regulations.
Prepackaged food products manufactured and sold/distributed in China (excluding imported prepackaged
food products) should be labeled with code and serial number of the product standards enforced.
4.1.11.1.1 Food irradiated with ionization radiation or energy should be labeled with “Irradiated Food” in the
proximity of the product name.
4.1.11.1.2 Any ingredient irradiated with ionization radiation or energy should be also be clearly indicated
that it is processed in such a way in the list of ingredients.
Label of genetically modified food should comply with the requirements of relevant laws and regulations.
4.1.11.3.1 Special dietary food and staple, supplementary food dedicated for infants, should indicate the
main nutritional contents and their corresponding composition. Labeling format should be in accordance to
GB 13432.
4.1.11.3.2 If other types of prepackaged food requires the presentation of nutritional labels, the format of
labeling should implemented with reference to relevant laws and regulations.
If the grade of products is clearly defined and regulated in corresponding product standards, the quality
grade that the products fall under should be indicated on the food labels.
Food label of prepackaged food indirectly supplied to consumers should comply with the corresponding
requirements specified in clause 4.1, indicating food name, specifications, net content, date of production,
shelf-life and storage conditions. Any of the contents not indicated on the label should be specified in the
user manual or contract.
4.3.1 The following prepackaged products can be exempted from indicating the shelf-life period (expiration
period): alcoholic beverages with alcohol content ≥10%; edible vinegar; edible salt; solid sugar category;
monosodium glutamate (MSG).
4.3.2 If the largest surface area of the packaging or container used for prepackaged food products is less
than 10cm2 (see Appendix A for the calculation methodology for computing largest surface area), only
product name, net content, name and address of manufacturer (or distributor) are required to be indicated
on the food label.
Batch number can be indicated depending on the requirements of the specific products.
Helpful instructions for consumers, such as packaging container’s method of opening, method of
consumption (eating), method of cooking, method of reliquefication can be included on the food label,
according to the requirements of the specific products.
4.4.3 Allergens
4.4.3.1 The following food and its products may cause allergic reaction, thus if they are used as ingredients,
easily identifiable names should be used in the list of ingredients, or word of caution should be added near
the list of ingredients:
a) Contains gluten-based grains and its products (e.g. wheat, rye, barley, oats, spelt or hybrid species
of a combination of the previously mentioned varieties);
4.4.3.2 If it is possible to include any of the abovementioned food or its products into the food processing
procedure, word of caution should be added near the list of ingredients.
5. Others
Presentation of food labels of products that require special approval according to relevant national
regulations should be implemented in accordance to the relevant regulations.
Multiply the height (cm) and the width (cm) of the largest side of the rectangle-shaped packaging or
container.
Multiply the height (cm) and 40% of the circumference of the packaging or container.
Use the surface area of the main display panel as the largest surface area if such main display panel
apparently exists on the product packaging or container.
When calculating the surface area of the packaging or its likes, subtract/eliminate the length/width dedicated
for sealing the sides of the packaging from the calculation. Surface area calculation excludes shoulder
region, neck region, top region and the convex part at the bottom for bottle or can shaped containers.
B.1 Specific Name of Food Additives Presented in Descending Order Based on Individual Amount
Added
Ingredients: Water, Full cream milk powder, Light cream, Vegetable oil, Chocolate (Cocoa mass, White
sugar, Cocoa butter, Phospholipid, Polyglycerol polyricinoleate, Food fragrance, Tartrazine), Glucose syrup,
Propanediol fatty acid esters, Carrageenan, Guar gum, Annatto, Maltodextrin, Food essence.
B.2 Functional Category and INS Code of Food Additives Presented in Descending Order Based on
Individual Amount Added
Ingredients: Water, Full cream milk powder, Light cream, Vegetable oil, Chocolate (Cocoa mass, White
sugar, Cocoa butter, Emulsifier (332, 476), Food fragrance, Coloring agent (102)), Glucose syrup, Emulsifier
(477), Thickener (407, 412), Coloring agent (106b), Maltodextrin, Food essence.
B.3 Functional Category and Specific Name of Food Additives Presented in Descending Order Based
on Individual Amount Added
Ingredients: Water, Full cream milk powder, Light cream, Vegetable oil, Chocolate (Cocoa mass, White
sugar, Cocoa butter, Emulsifier (Phospholipid, Polyglycerol polyricinoleate), Food fragrance, Coloring agent
(Tartrazine), Glucoes syrup, Emulsifier (Propanediol fatty acid esters), Thickener (Carrageenan, Guar gum),
Coloring agent (Annatto), Maltodextrin, Food essence.
B.4 Establishing Consistent Presentation Format for Food Additive Group Parentheses
Food additives added directly should be indicated in the food additive group parentheses. Nutritional
supplements, food fragrance and essence, base agent and substance in gum-based candies/sweets can be
listed outside the food additive group parentheses. Food additives added indirectly will not be indicated
within the food additive group parentheses. The order of presentation of food additives within the list of
ingredients should be decided based on the total weight of the specific food additives used in the product.
Ingredients: Water, Full cream milk powder, Light Cream, Vegetable oil, Chocolate (Cocoa mass, White
sugar, Cocoa butter, Phospholipid, Polyglycerol polyricinoleate, Food fragrance, Tartrazine), Glucose syrup,
Food additives (Propanediol fatty acid esters, Carrageenan, Guar gum, Annatto), Maltodextrin, Food
essence.
B.4.3 Presentation of All Food Additives in Their Functional Category and INS Code
Ingredients: Water, Full cream milk powder, Light Cream, Vegetable oil, Chocolate (Cocoa mass, White
sugar, Cocoa butter, Emulsifier (332, 476), Food fragrance, Coloring agent (102)), Glucose syrup, Food
additives (Emulsifier (477), Thickener (407, 412), Coloring agent (106b)), Maltodextrin, Food essence.
Ingredients: Water, Full cream milk powder, Light Cream, Vegetable oil, Chocolate (Cocoa mass, White
sugar, Cocoa butter, Emulsifier (Phospholipid, Polyglycerol polyricinoleate), Food fragrance, Coloring agent
(Tartrazine), Glucose syrup, Emulsifier (Propanediol fatty acid esters), Thickener (Carrageenan, Guar gum),
Coloring agent (Annatto), Maltodextrin, Food essence.
C.1 Overview
This Appendix provides the recommended presentation formats for some of the components of the
prepackaged food label through the use of examples and illustrations, despite that presentation format is
not limited only to these recommended formats for the specific label components. If certain format
modifications are required due to unique characteristics of food products or specific nature of the
packaging, it is necessary to ensure that the modified format is still consistent with the fundamental
meaning of the recommended formats.
For convenience of illustration, examples for net content information use weight-based units of
measurement, with colon symbol as separator. Food label should use the appropriate unit of
measurement, and spacing or other symbols can be used as separator according to actual circumstances,
so as to facilitate reading for consumers.
C.2.1 Net content (specifications) of single prepackaged food can be presented in the following formats:
C.2.2 Net content of drained product (solid mass) can be presented in the following formats (using
example on semi-solid canned pear in syrup):
Net content (or net content/specification): 425g drained (or solid or pear chunks): no less than 225g (or no
less than 60%).
C.2.3 When a single prepackaged food packaging contains multiple individual prepackaged food products
of the same product category, net content and specifications can be presented in the following formats:
C.2.4 When a single prepackaged food packaging contains multiple individual prepackaged food products
of different product category, net content and specifications can be presented in the following formats:
Net content (or net content/specification): 200g (product A 40g×3, product B 40g×2)
Net content (or net content/specification): 100g product A, 50g×2 product B, 50g product C
Net content (or net content/specification): product A: 100g, product B 50g×2, product C 50g
Net content/specification: 100g (product A), 50g×2 (product B), 50g (product C)
Numbers used for individual day, month and year in the dates listed can be separated by spacing, or
symbols like slashes, hyphens, period, or not presented without any separator formerly mentioned.
Generally, four-digit format is used for presentation of year, although two-digit format can be used for
smaller packaging. Two-digit format is used for presentations of month and day.
2010.3.20;
Eat (or drink) best before…; before… eat (or drink) is best;
Before the date of … is best; eat (or drink) before the date of … is best;
The expiration date is...; the expiration is … months (or days, weeks, years).
Storage conditions information can be titled as “Storage Conditions” “Holding Conditions” “Holding
Store at room temperature (or refrigerated, frozen, in the dark, at shady and dry locations);
Stored at xx - xx°C;
GB 28050-2011
1. Scope
This standard applies to the description and presentation of nutrition information on nutrition labeling of a
prepackaged food.
This standard does not apply for the nutrition labeling for health food nor pre-packaged food for special
dietary uses.
Nutrition labeling
Nutrition labeling is a description intended to inform the consumer of the nutritional information and the
nutritional properties of a food, which includes nutrition components table, nutrition claims and nutrient
function claims. Nutrition labeling is a part of food labeling.
a) Nutrients
Substances in food with specific physiological role to maintain the body's growth, development, activities,
reproduction, and normal metabolism, which include protein, fat, carbohydrates, minerals and vitamin, etc.
b) Nutritional component
Nutritional component refers to nutrients or other component in food in addition to nutrients which have
nutritional properties of a food, which includes nutrition components table, nutrition claims and nutrient
function claims. Nutrition labeling is a part of food labeling.
c) Core Nutrient
Core nutrients in nutrition labelling include protein, fat, carbohydrates, and sodium, etc.
A normative form with the name of nutrient component, the content of nutrient component and % NRV
(Nutrient reference value).
Nutrient Reference Value (NRV) is a reference value especially for food nutrition labelling purpose, and to
compare the content levels of nutrient components.
f) Nutrition claim
Nutrition claim refers to a description and declaration of the nutritional properties of a food, such as
declaration of energy value and content claim of protein. Nutrition claim includes content claim and
comparative claim.
Content claim means a claim that describes the energy or the nutrient content level in a food. The diction for
nutrient content claim includes "contains", "high", "low" or "no", etc.
Comparative claim means a claim that compares the energy value or the content level of a nutrient in a food
with other foods of same type known by consumers. The diction includes "add", "reduce", etc.
A claim that describes the role of a nutrient component in normal growth, development and normal
physiological function of the body.
h) Rounding interval
i) Edible parts
Edible parts of a food refer to the remaining parts that can be consumed after the removal of those
non-edible parts of the net content of the prepackaged food.
3. General requirements
a) Any nutrition information presented on a nutrition label of a food should be truthful, subjective and not be
in any deceptive, not to exaggerate the nutritional or other functions.
b) Nutrition label of the prepackaged food should be written in Chinese. If a foreign language is also
adopted, its content should be in correspondence with which in Chinese. The foreign letters shall not larger
than the corresponding Chinese characters.
c) The nutrition components of a food should be indicated in form of box table (except in exceptional
circumstances) which can be any size and should be perpendicular to the baseline of the packaging. The
title of the table should be Nutrition Components Table.
d) The content of a nutrition component in food should be indicated in a special value which may be
obtained by calculation using that of raw materials or by product detection. The nutrient reference values
(NRV) of the nutrient components are established in the Annex A.
e) The nutrition label formats are specified in the Annex B. The food companies can choose one of them
according to the elements such as nutrition property, packaging dimension and shape, etc.
f) The nutrition label should be indicated in the packaging of the minimum sales unit offered to the
consumers.
a) Energy, core nutrients content value and percentage in the nutrient reference values (NRV) are
mandatory labeling items on a nutrition label of prepackaging foods. When there are other nutritional
components to be claimed, appropriate measures shall be taken to highlight the claims of energy and core
nutrients.
b) When other nutrient components besides energy and core nutrients should be made nutrition claim or
nutrient function claim. In the Nutrient Components Table, this nutrient component content and the nutrient
reference values (NRV) in which represents should be claimed.
c) The prepackaged food in which the food nutrition enhancer has been used, in addition to the
requirement of the 4.1, in the Nutrient Components Table, this nutrient component content and the nutrient
reference values (NRV) in which represents after enhancement should be claimed.
d) If the food ingredients content hydrogenated and/or partial y hydrogenated fats and oils, or they have
been used in the production, in the Nutrient Components Table, the content of Tran’s fat (acid) should be
claimed.
e) The nutrient components whose nutrient reference values (NRV) are not established in the above points
only need to claim the content.
a) In addition to the above mandatory label content, in the Nutrient Components Table, the other
components in the Table 1 could be claimed optional.
b) When the claimed value of one nutrient component meets the content requirement and the restrictive
conditions in the Table C.1, the content claim of this component could be made and the claim form is showed
in the Table C.1. When the content of one nutrient component meets the requirements and conditions in the
Table C.3, the comparative claim of this component could be made y de claim form is showed in the Table
C.3. When one nutrient component meets the requirements of content claim and comparative claim, the two
claim forms could be used at the same time, or only use de content claim. The synonymous of the content
claim and the comparative claim are in the Table C.2 and Table C.4.
c) When the claimed value of one nutrient component meets the requirements and conditions of content
claim or comparative claim, one or various standard expressions of function claim of the nutrient component
in the Annex D could be used. No excision, adjunction and mergence in any form to the expressions of
function claim should be made.
a) The content level of energy and nutrient components in prepackaged food shall be expressed in
“amount per 100g” and (or) “amount per 100mL” and (or )“Specified numerical values of the edible part per
serving”. The quantity of per serving should be indicated if “Per serving” expression is adopted and the size
of per serving can be defined in according to the features of the food.
b) The name, regular succession, claim unit, rounding interval, definition of “0” of the nutrient
component which need mandatory claim and optional claim in the Nutrient Components Table should be in
compliance with the provisions listed in Table 1. When a nutrient component is not claimed, the other items
move up in order to the sequence.
Table 1: Name, Sequence, Expression units, Rounding interval and Definition of “0” for Energy and
Nutritional Components
Name and order of
Limit value of “0”
energy/nutritional Labeled unita Rounding interval
(Per 100 g or 100ml)b
components
Energy kJ 1 ≤17 kJ
Protein g 0.1 ≤ 0.5 g
Fat g 0.1 ≤ 0.5 g
Saturated fat (fatty acid) g 0.1 ≤ 0.1 g
Trans fat (fatty acid) g 0.1 ≤ 0.3 g
Monounsaturated fat (fatty
g 0.1 ≤ 0.1 g
acid)
Polyunsaturated fat (fatty
g 0.1 ≤ 0.1 g
acid)
Cholesterol mg 1 ≤ 5 mg
Carbohydrate g 0.1 ≤ 0.5 g
Sugar (Lactose c) g 0.1 ≤ 0.5 g
Dietary fiber (or monomer
of fiber or soluble dietary
g 0.1 ≤ 0.5 g
fiber or insoluble dietary
fiber)
Sodium mg 1 ≤ 5 mg
Vitamin A μgRE 1 ≤ 8µgRE
Vitamin D Μg 0.1 ≤0.1µg
Vitamin E mg a-TE 0.01 ≤0.28mgα-TE
Vitamin K μg 0.1 ≤1.6µg
Vitamin B1 mg 0.01 ≤0.03mg
Vitamin B2 mg 0.01 ≤0.03mg
Vitamin B6 mg 0.01 ≤0.03mg
Vitamin B12 μg 0.01 ≤0.05µg
Vitamin C mg 0.1 ≤2.0mg
Nicotinic acid mg 0.01 ≤0.28mg
Folacin/Folic acid μg or μg DFE 1 ≤8µg
Pantothenic acid mg 0.01 ≤0.10mg
Biotin μg 0.1 ≤0.6µg
Choline mg 0.1 ≤9.0mg
Phosphorus mg 1 ≤14mg
Potassium mg 1 ≤20mg
Magnesium mg 1 ≤6mg
Calcium mg 1 ≤8mg
Iron mg 0.1 ≤0.3mg
Zinc mg 0.01 ≤0.30mg
Iodine μg 0.1 ≤3.0µg
Selenium μg 0.1 ≤1.0µg
Copper mg 0.01 ≤0.03mg
Fluorine mg 0.01 ≤0.02mg
Manganese mg 0.01 ≤0.06mg
a Labeled units can be in Chinese or English, or both.
b Define it “0”when content of a certain nutritional component is less than or equals to the limit value of “0”.The
regulations on the limit value of “0” (per 100g or per 100ml) shall also be met when “per serving” expression is adopted.
c It can be directly indicated as “lactose” on a nutrition label of milk or milk product.
Table 2: Allowed error range for content of energy and nutritional components
Nutrients in foods Allowed error range
Protein, Polyunsaturated fat (fatty acid),
Monounsaturated fat (fatty acid), Carbohydrates,
Sugars (only lactose), Total dietary fiber (soluble fibre,
≥80% declared value
insoluble fibre), individual component of fibre Vitamins
(other than Vitamin D, Vitamin A), Minerals (exclude
Sodium), other nutrients enhanced in food
Energy, Fat, Saturated fat (fatty acid), Trans fat (fatty
acids), Cholesterol, Sodium, Sugars (exclude lactose) ≤120% declared value
in food
Vitamin D and Vitamin A in food 80% ~ 180% declared value
Prepackaged foods of following types are exempt from rules on nutrition labeling:
• Fresh food, such as packed raw meat, raw fish, raw vegetables and fruits, fresh eggs, etc;
• Packaged food with total surface area of no more than 100 cm2 or the largest surfaces area of the
package is no more than 20 cm2;
• Food sold on the site which is usual y bought for immediate consumption;
• A prepackaged food that the daily intake amount shall be no more than 10g or 10ml.
• Those prepackaged foods which falling with the criteria of exemptions of food labels according to the
laws, regulations and standards.
The exemption will be removed if a nutrition claim is made on prepackaged food listed above. And the
nutrition labeling of this product should meet the requirements specified in this standard
NRVs for energy and 32 types of specified nutrients are listed in Table A.1.
NRV is used to compare and describe energy level or the content level of nutrients. When nutrition claims
and the definition of “0” are adopted for expression, NRV may be used as a standard reference value.
3. A.3 Calculation
B.2. One of the bel owing six formats of nutrition labels should be adopted.
The nutrition label in which only the energy and core nutrients are claimed refers to the example 1.
Example 1:
Example 2:
Note: the core nutriment should label in appropriate format to make it striking.
Example 4:
Nutrient Nutrient
per per
Reference Reference
Item 100g/100ml or Item 100g/100ml or
Value % or Value % or
per serving per serving
NRV% NRV%
Energy kJ % Protein g %
Carbohydrate g % Fat g %
Sodium g % -- -- %
* According to the packing characteristics, nutrients can be arranged horizontally from left to right, dividing
into two rows or more.
For foods whose total area of package less than 100cm2, when labeling the nutrition information, the NRV
can be omitted. Nutrients can be arranged horizontally from left to right, or vertically up to down according to
the packing characteristics. For example:
Example 5:
Nutrition Information
Nutrition Function Claim. Such as: Energy from fat should not exceed 30% of total energy for daily diet.
Nutrition claim and/or nutrition function claim can be labeled on anywhere of the label, but the font size
should not exceed the food name and the trademark.
Requirements, Conditions and Synonyms for Energy and Nutrient Content Claim and
Comparison Claim
C.1 The Table C.1 provides for requirements and conditions for nutrient content claim and comparative
claim of emerge and nutritional components.
C.2 Table C.2 provides for synonyms for nutrient content claim of energy and nutritional components.
C.3 Table C.3 provides for requirements and conditions for nutrient comparative claim of energy and
nutritional components.
C.4 Table C.4 provides for synonyms for nutrient comparative claim of energy and nutritional components.
Table C.1 Requirements and conditions for nutrient content claim and comparative claim of emerge
and nutritional components
Content Claim
Item Content demanda Restriction
Mode
No energy ≤17 kJ/100g (solid) or 100ml (Liquid)
Energy from fat ≤50% of total
Energy ≤170 kJ/100g solid
Low energy energy
≤80 kJ/100ml liquid
Energy from protein ≤ 5% of Total energy refers to per
Low protein
total energy 100g/ml or per serving
Content /100 g≥10% NRV
Origin of protein,
Content /100 ml ≥5% NRV
Protein or include protein
or Content /420 kJ ≥5% NRV
Content /100 g≥20%NRV
High, or rich in
Content /100 ml ≥10%NRV
protein
or Content /420 kJ ≥10%NRV
No fat or not
≤0.5 g/100g (solid) or 100ml (liquid)
including fat
Low fat ≤3 g/100g solid; ≤1.5g/100ml liquid
Refer to livestock and poultry
Lean Fat content ≤10%
only
Liquid milk and yoghurt:fat ≤0.5%,
Skim Refer to dairy products only.
Milk powder:fat ≤1.5%
No or not
Fat ≤0.1 g/ 100g(solid) or 100ml Refer to sum of saturated fat
including
(liquid and trans fat
saturated fat
1. Refer to sum of saturated
Low saturated ≤1.5 g/100g solid fat and trans fat
fat ≤0.75 g /100mL liquid 2. energy from saturated fat no
more than 10% of total
No or not ≤0.3 g/100g (solid) or 100ml
including transfat (liquid)
No or not
≤5 mg/100g (solid) or 100ml
including Should comply with both
(liquid)
Cholesterol cholesterol demand and restriction for
≤20m g /100g solid; low saturated fat claim
Low cholesterol
≤10m g /100ml liquid
Comparative Claim
Requirements Conditions
Form
Compared with the reference food,
Energy reduced
energy value is reduced by 25% or more
Compared with the reference food,
Protein enhanced or
protein content is enhanced or reduced
reduced
by 25% or more
Compared with the reference food, fat
Fat reduced
content is reduced by 25% or more
Compared with the reference food,
Cholesterol reduced cholesterol content is reduced by 25%
or more
Compared with the reference food,
Carbohydrate
carbohydrate content is enhanced or
enhanced or reduced The reference food should
reduced by 25% or more
be of the same type or
Compared with the reference food,
genus which is well known
Sugar reduced sugar content is reduced by 25% or
by the consumers and easy
more
to be understood.
Compared with the reference food,
Dietary fiber enhanced
dietary fiber content is enhanced or
or reduced
reduced by 25% or more
Compared with the reference food,
Sodium reduced sodium content is reduced by 25% or
more
Mineral (exclude Compared with the reference food,
sodium) enhanced or mineral content is enhanced or reduced
reduce by 25% or more
Compared with the reference food,
Vitamin enhanced or
vitamin content is enhanced or reduced
reduced
by 25% or more
D.1 The present Appendix specifies the standard language of energy and nutrition function claim.
D.2 Energy
Over intake of energy and insufficient exercise are related with overweight and obesity.
D.3 Protein
Protein is the main component of body and could provide various kinds of amino acids.
Protein is essential to human life activities, as wel as contributing to tissue formation and growth.
D.4 Fat
Energy from fat should not exceed 30% of total energy for daily diet.
Fat could provide the essential fatty acid for human body.
Excessive intake of saturated fat will cause increase of cholesterol, so the intake should be less than 10% of
Intake of Trans fatty acid should be less than 2.2g everyday and the excessive intake wil do harm to health.
Copyright @ 2015 The Sovereign Group All Rights Reserved
33
Intake of Trans fatty acids should be less than 1% of total energy every day. Excessive intake wil do harm
to health.
Excessive intake of trans fatty acid will increase the cholesterol in blood, thereby increasing the risk of
Cardiovascular disease
D.5 Cholesterol
For adults, the intake of cholesterol should not exceed 300mg for daily diet.
D.6 Carbohydrate
Carbohydrate is a basic compound for human life, also the main source of energy.
D.8 Sodium
Sodium could adjust the water balance of body, hence the acid-base balance.
D.9 Vitamin A
D.10 Vitamin D
D.11 Vitamin E
D.13 Vitamin B2
D.14 Vitamin B6
D.16 Vitamin C
D.17 Niacin
Folic acid helps the growth of brain and neural system for embryo.
D.20 Calcium
Calcium is the main component for human bone and tooth, also participating many of the physiological
function.
Copyright @ 2015 The Sovereign Group All Rights Reserved
35
Calcium is the main component for bone and tooth, as well as maintaining bone density.
D.21 Magnesium
Magnesium is essential for energy metabolism, tissue formation and bone growth.
D.22 Iron
D.23 Zinc
D.24 Iodine
Supplies
GB 13432-2013
This standard replaces "General Standard for the Labeling of Prepackaged Foods for Special Dietary
Uses" (GB 13432-2004).
Compared with GB 13432-2004, this standard has the following main changes:
- The definition of foods for special dietary supplies was modified, and the food category (scope) was
defined;
- The permissible and recommended indication contents were combined and modified into optional
indication contents;
- The content claim requirements of energy and nutritional ingredients were modified;
- The function claim wording of energy and nutritional ingredients was modified;
The types of foods for special dietary supplies in Appendix A were added
1. Scope
This standard is applicable to the labeling (including nutrition labeling) of prepackaged foods for special
dietary supplies.
For the purpose of this standard, the terms and definitions specified in GB 7718 and the following ones
apply.
The foods specially processed or formulated to meet the special dietary demand under special physical or
physiologic conditions and (or) disease and disorder. The content of the nutrient and (or) other nutritional
ingredients in such foods is significantly different from that in comparable ordinary foods.
See Appendix A for the food categories covered by foods for special dietary supplies.
2.2 Nutrients
The substances which have specific physiological effect, be able to maintain the growth, development,
activities, and reproduction of organism, and are necessary for normal metabolism, including protein, grease,
carbohydrate, minerals and vitamin, etc.
The nutrients in food and other food ingredients (except nutrients) having nutrition and (or) physiological
functions.
The nutrient intake level which can meet the need of the most individuals in a specific gender, age and
physiologic status medium group.
A safe intake level of nutrient. The intake of some nutrients for healthy people obtained by observation or
experiment.
3. Basic Requirements
The labeling of prepackaged foods for special dietary supplies shall meet the basic requirements specified in
GB 7718 and the following the requirements:
- Content claim and comparison claim shall not be conducted to the essential
ingredients in the formula foods for infants aged 0~6 months.
The contents indicated on the label of prepackaged foods for special dietary supplies shall meet the
requirements of corresponding clauses in GB 7718.
Only the foods meeting the requirements defined in 2.1 may use "foods for special dietary supplies" in the
name or the corresponding name describing product specificity.
4.3.1 Energy, protein, grease, carbohydrate and sodium as well as other nutritional ingredients required
in corresponding product standards and their contents shall be indicated in the form of "block table". The
block may be of any dimension and vertical to the packed base line, the table title is "Nutrition Information". If
optional ingredients are added or some substances are intensified in the product according to relevant laws
and regulations or standards, these ingredients and their contents shall also be indicated.
4.3.2 The energy and nutrient contents in prepackaged foods for special dietary supplies shall be
indicated by every 100 g and every 100mL and the specific value in the edible part of each portion of food.
Where it is indicated by portion, the amount of each portion of food shall be indicated, the size of each
portion may be determined according to the characteristics or the recommended amount of the food. If
necessary or it is required in corresponding product standards, the content of nutritional ingredients in
product per 100 KJ shall also be indicated.
4.3.3 The indication values of energy or nutritional ingredients may be obtained through product testing or
raw material calculation. In the quality guarantee period of the products, the actual content of energy and
nutritional ingredients shall not be less than 80% of the indicated value, and shall meet the requirements of
corresponding product standards.
4.3.4 If the proteins in the prepackaged foods for special dietary supplies are provided by hydrolyzed
protein or amino acid, the item "proteins" may be indicated by "proteins", "proteins (equivalent)" or "total
amount of amino acid".
4.4.1 The edible method, daily intake or intake each time of prepackaged foods for special dietary
supplies shall be indicated; if necessary, mixing and rehydration reproduction methods shall be indicated.
4.4.2 The suitable group of prepackaged foods for special dietary supplies shall be indicated.
As for infant formula foods for special medical use and formulated foods for special medical use, the
suitable group shall be indicated according to the requirements of product standard.
4.5.1 The storage conditions of prepackaged foods for special dietary supplies shall be indicated on label,
if necessary, the storage conditions after opening shall be indicated.
4.5.2 Consumers shall be specially warned if the opened prepackaged foods for special dietary supplies
should not be stored or should not be stored in the original packaging container.
When the maximum surface area of the wrappage or packaging container of the prepackaged foods for
special dietary supplies is less than 10cm2, it is allowable to only indicate the product name, net content,
name and address of the manufacturer (or distributor), production date and quality guarantee period.
5.1 The mass percentage of energy and nutritional ingredients to recommended intake or
adequate intake
The energy value and content value of nutritional ingredients shall be indicated, and the mass percentage
of energy and nutrient content in 100g and 100ml and (or) each portion of food to DRIs-recommended
intake (RNI) or adequate intake (AI) may be indicated according to the suitable group, e.g. X%. The
nutrients without recommended intake (RNI) or adequate intake (AI) may not be indicated with mass
percentage, or be indicated by "-".
5.2.1 Content claim may be conducted when the content of energy or nutritional ingredients in the
product reaches the minimum value of corresponding product standard or the permissible intensified
minimum value.
5.2.2 Where there is no minimum value requirement or minimum intensification amount for the nutritional
ingredients in product standards, the criterion of other national and (or) international organization's
permission to conduct content claim of this nutritional ingredient shall be provided.
5.2.3 The content claim wording includes "contain", "provide", "source", "including" and "have", etc..
5.3.1 As for the prepackaged foods for special dietary supplies meeting content claim requirements, the
function claim of energy and (or) nutritional ingredients may be conducted. The wording of function claim
shall be the standard wording for function claim specified in GB 28050.
5.3.2 As for the nutritional ingredients for which the standard wording of function claim is not listed in
GB 28050, the criterion for the function claim wording of this substance specified by other national and (or)
international organizations shall be provided.
c) Formula foods for special medical use (the variety involved in infant formula foods for special medical
use are excluded);
d) Other foods for special dietary supplies apart from the above-mentioned categories (including
complementary nutrition goods, athletic nutrition foods and other foods for special dietary supplies with
corresponding national standards).
GB 2762-2012
- Adjusted the limit indicators of maximum levels of N-nitrosamine from N-Nitrosodimethylamine and
N-dimethylnitrosamine to N-Nitrosodimethylamine;
1. Scope
This standard stipulates the indicators of maximum levels of lead, cadmium, mercury, arsenic, tin, nickel,
chromium, nitrate, nitrite, benzo (a) pyrene, N-nitrosamines, polychlorinated biphenyls (PCBs) and
3-chloro-1, 2-propanediol in foods.
2.1 Contaminants
Contaminant refers to any materials unintentionally added into the foods during the production (including
planting crops, raising animals and applying veterinary medicines), processing, packaging, storage,
transportation, sales, consumption of foods or any materials resulting from environmental pollution, the
contaminant in this Standard refers to those other than pesticide, veterinary medicines and toxins in fungi.
2.2 Edible Parts
Edible parts refer to the usually edible and drinkable parts obtained from the food raw materials after the
inedible parts of the food raw materials are dispelled by mechanical means when bones are removed from
meat or fish, the shellfish is shelled, the grains are milled, the fruit is peeled and the nuts are shelled, but
excluding the dispelling process that other method is required (such as getting refined vegetable oil from
unrefined vegetable oil).
The inedible parts dispelled from the edible parts of the foods are usually based on the processed finished
products that meet specified standards, for example, when wheat is made into cereal or whole wheat noodle,
the edible part is 100%, when made into flour, it shall be discounted according to flour yield.
2.3 Maximum Levels,MLs
The maximum density of contaminants allowed in edible parts of the food raw materials and/or finished food
products.
3. Principle of Application
3.1 Regardless if there is any contamination limit specified, food production and processing parties should
take appropriate control measures so as to ensure that the content of contaminants in foods attains the
lowest possible level.
3.2 This standard listed all the contaminants that may pose a significant risk to public health and the food
categories with limit values specified are representative of foods that have significant effect on the
consumer’s dietary exposure.
3.3 Descriptions (Appendix A) of food categories (names) used in setting the scope of application for the
maximum levels of contaminants in foods are only applicable to this standard. When maximum limit on a
specific contaminant is applied towards a specific food category (name), the limit will be applicable for all
types of food that fall under the definition of this food category (name), unless otherwise stated.
3.4 Maximum limit of contaminants is computed based on the general edible parts of the food, unless
Copyright @ 2015 The Sovereign Group All Rights Reserved
45
otherwise stated.
3.5 Maximum limits of contaminants for dried or dehydrated food is adjusted in accordance to the
dehydration rate or concentration ratio of the corresponding food raw ingredients. Dehydration rate or
concentration ratio can be determined through analysis of food products, information provided by
manufacturers and other statistics or information obtainable or available.
4. Index Requirements
4.1 Lead
See Table 1 for indicators of maximum levels of lead in foods.
4.2 Cadmium
4.6 Nickel
4.7 Cadmium
4.8.1 See Table 8 for indicators of maximum levels of nitrite and nitrate in foods.
4.8.2 Inspection methods: Beverage according to GB/T 8538, others according to GB 5009.33
4.10 N-nitrosamine
4.11.1 See Table 11 for indicators of maximum levels of Polychlorinated biphenyls (PCBs) in foods.
4.12.1 See Table 12 for indicators of maximum levels of 3-chloro-1, 2-propanediol in foods.
GB 29921-2013
1. Scope
This standard specifies the index limit requirements on pathogenic bacterium and corresponding testing
methods.
2.1 It is necessary to minimize the level of content of pathogenic bacterium in food and its corresponding
probability of risks through establishing control mechanisms and system for the production, processing and
distribution of food products, regardless of whether there are existing stipulated limits on pathogenic
bacterium.
2.2 Inspection should be implemented in accordance with the testing methods specified in Table 1 after
taking samples based on the sampling methodology specified in GB 4789.1.Limits of Pathogenic
3. Requirements on Index
GB 5009.12-2010
1. Scope
This Standard regulates the method for the determination of lead in foods. This Standard applies to the
determination of lead in foods.
2. Normative documents
The reference cited in this standard is necessary. For the cited documents which are labeled with date, all
their subsequent modification sheets or modified versions are not applicable for this standard. For the cited
documents which are not labeled with date, their latest versions are applicable for this standard.
3. Principle
After ashing or acid digestion, the sample is injected into the graphite furnace of atomic absorption
spectrophotometer. It then absorbs the resonance line at 283.3 nm after electrothermal atomization. In
certain concentration range, the absorption is proportional to lead content, and is used to yield quantitative
lead content on the basis of comparison with standard series.
Unless other specified rules, all the reagents used in this method are pure, and water shall be grade I under
the GB/T 6682.
4.5 Nitric acid (1+1): 50 mL of nitric acid is slowly added into 50 mL of water.
4.6 Nitric acid (0.5 mol/L): 3.2 mL of nitric acid is added into 50 mL of water and then diluted to 100 mL.
4.7 Nitric acid (1 mol/L): 6.4 mL of nitric acid is added into 50 mL of water and then diluted to 100 mL.
4.8 Ammonium phosphate solution (20 g/L): dissolve 2.0 g of ammonium phosphate in water and then
diluted to 100 mL.
4.9 Mixed acid: Nitric acid + perchloric acid (9+1). 9 volume of nitric acid is mixed with 1 volume of
perchloric acid.
4.10 Standard lead stock solution: weigh 1.000 g of lead (99.99%) accurately, added with a small
Copyright @ 2015 The Sovereign Group All Rights Reserved
69
amount of nitric acid (1+1) for several times and heated to dissolve. The total volume of nitric acid is not
more than 37 mL. Then transfer into a 1000 mL volumetric flask and make up to the mark. Mix well. Lead
concentration in the solution is 1.0 mg/mL.
4.11 Standard lead working solution: Pipette 1.0 mL of standard lead stock solution in a 100 mL volumetric
flask and make up to the mark with nitrate acid (4.6). Do so several times to obtain standard lead working
solution with concentrations of 10.0 ng/mL, 20.0 ng/mL, 40.0 ng/mL, 60.0 ng/mL and 80.0 ng/mL.
5.1 Atomic absorption spectrophotometer, with graphite furnace and lead hollow cathode lamp.
5.5 Pressure digestion device, pressure digestion drum or pressure digestion tank.
6. Analysis procedure
6.1.1 During sampling and preparation, the sample should be prohibited from contamination
6.1.2 After the removal of impurities, grain and beans are ground, pass through a 20-mesh sieve, and are
stored in the plastic bottle for use.
6.1.3 Fresh samples with a high water content such as vegetables, fruit, fish, meat and eggs are
processed into homogenate by using food processing machine or homogenizers, and then
stored in the plastic bottle for use.
6.2 Sample digestion (any digestion method can be selected according to laboratory conditions)
6.2.1 Digestion by pressure digestion tank: 1 g-2 g of sample (nearest to 0.001g, for dry sample and
samples with high fat contents, the weight is less than 1 g; for fresh sample, the weight is less than 2 g; or
the weight can be determined according to the recommendation in operation instructions of the pressure
digestion tank) is weighed, placed in polytetrafluorethylene inner tank, and soaked in 2 mL-5 mL of nitric acid
(4.1) overnight. Added 2 mL-3 mL of hydrogen peroxide (4.3) (total volume not exceeding 1/3 of the tank
volume). Cover the inner lid and tighten the
stainless steel outer cover, put into dryer thermostat to stand for 3-4 hours under 120oC-150oC, and then
cooled to room temperature naturally in the oven. The digestion solution is washed and transferred into or
filtered into (depending on the salt content of the sample after digestion) a 10 mL-25 mL volumetric flask
using a dropper. A small amount of water is used to wash the tank for many times and then transferred into
the volumetric flask, make up to the mark. Mix well. Meanwhile, the reagent blank is prepared.
6.2.3 Ammonium persulfate ashing method: into porcelain crucible weigh 1 g-5 g of sample (nearest to
0.001g), add 2 mL-4 mL of nitric acid (4.1) to soak the sample for more than 1 h. Carbonized under low
power at first. After cooling add 2.00 g-3.00 g of ammonium persulfate (4.2) and continues to be carbonized
until no smoke is produced. Transfer to muffle furnace to stay for 2 h at 500oC, then 20 min at 800oC and
cools down after. Add 2 mL-3 mL of nitric acid (4.7), the sample digestion solution is washed and transferred
into or filtered into (depending on the salt content of the sample after digestion) a 10 mL-25 mL volumetric
flask using a dropper. A small amount of water is used to wash the porcelain crucible for many times and
then transferred into the volumetric flask, make up to the mark. Mix well. Meanwhile, the reagent blank is
prepared
6.2.4 Wet digestion method: Into a flask or tall beaker, weigh 1 g-5 g (the nearest to 0.001g) add several
glass beads and 10 mL of mixed acid (4.9). The container is then covered to allow the sample to be soaked
overnight. After that, digest on a small funnel electric furnace. If become dark brown, more mixed acid
should be added until white smoke is produced and the digestion solution is colorless and transparent or a
little yellow. Cool down and is washed and transferred into or filtered into (depending on the salt content of
the sample after digestion) a 10 mL-25 mL volumetric flask using a dropper. A small amount of water is used
to wash the flask or tall beaker for many times and then transferred into the volumetric flask, make up the
mark. Mix well. Meanwhile, the reagent blank is prepared.
6.3 Determination
6.3.1 Equipment conditions: adjust equipment to the best situation according to its performance. Reference
conditions are as follows: wavelength 283.3 nm, slot 0.2
-1.0 nm, lamp current 5-7 mA, drying temperature 120oC, 20 s; ashing temperature
450oC, 15 s-20 s; atomization temperature 1700oC-2300oC, 4-5s; the background calibration is based on
deuterium lamp or Zeeman Effect.
6.3.2 Preparation of standard curve: pipette10 μL of each standard lead working solution with a
concentration of 10.0, 20.0, 40.0, 60.0 and 80.0 ng/mL (or μg/L) respectively and injected into the graphite
furnace, measure absorbance and make unary linear regression equation between concentration and
absorbance
6.3.3 Sample determination: Pipette 10 μL of sample solution and reagent blank control solution and
injected into the graphite furnace to measure absorbance. Then calculate the determination according to
unary linear regression equation as the step 6.3.2 shows.
6.3.4 Application of matrix modifier: For samples with interference factors, inject an appropriate amount of
matrix modifier of ammonium phosphate solution (4.8), (usually 5 μL or equivalent to the amount of sample),
to eliminate the interference. During the preparation of lead standard curve, the matrix modifier ammonium
7. Calculation of results
The lead content of the sample is calculated on the basis of equation (1).
(C1−C0)×V×1000
X= m×1000
……………………………………………. (1)
C1 -- Lead content in determination sample solution, ng/mL; C0 -- Lead content in blank control solution,
ng/mL;
V -- Total quantitative volume of the sample digestion solution, mL; m -- Weight or volume of the sample, g or
mL.
Report the results in terms of arithmetic average from two independent measurements under the repeatable
conditions, and possess two significant digits.
8. Degree of precision
The absolute difference between two independent determination results obtained under repeatable
conditions is not allowed to exceed 20% of the arithmetic average of them.
9. Principle
After thermal acid digestion, the sample is placed in the acid medium to allow lead existed in it to react with
sodium borohydride (NaBH4) or potassium borohydride (KBH4) to yield volatile lead hydride (PbH4). The
hydride is introduced into electrothermal quartz atomizer using carrier gas argon to undergo atomization.
Under the illumination of special lead hollow cathode lamp, lead atoms at the ground state are excited to a
high energy state. After deactivation, the excited lead atoms get back to the ground state and emit
fluorescence light with a characteristic wavelength and with a fluorescent intensity proportional to lead
content. Such a relationship is used for the quantitative determination on the basis of standard series.
10.1 Nitric acid and perchloric acid mixture (9+1): mix 900 mL of nitric acid and 100 mL of perchloric acid.
10.2 Hydrochloric acid solution (1+1): introduce 250 mL of hydrochloric acid into 250 mL of water
10.3 Oxalic acid solution (10 g/L): dissolve1.0 g of oxalic acid in 100 mL of water and mixed well.
10.4 Iron potassium cyanide [K3Fe(CN)6] solution (100 g/L): dissolve 10.0 g of iron potassium cyanide in
water, diluted to 100 mL and mixed well.
10.5 Sodium hydroxide solution (2 g/L): dissolve 2.0 g of sodium hydroxide in 1 L of water and mixed
well.
10.6 Sodium borohydride [NaBH4] solution (10 g/L): dissolve 5.0 g of sodium borohydride in 500 mL of
Copyright @ 2015 The Sovereign Group All Rights Reserved
72
sodium hydroxide solution (2 g/L) and mixed well. This solution should be prepared right before use.
10.8 Standard lead working solution (1.0 μg/mL): pipette a certain amount of standard lead stock
solution (1.0 mg/mL) and diluted to 1.0 μg/mL step by step.
Wet digestion: into 50 mL-110 mL digestion vessel (flask), weigh 0.2 g-2 g of solid sample or 2.00 g (or mL) -
10.00 g (or mL) of liquid sample (nearest to 0.001g), add 5 mL-10 mL of nitric acid and perchloric acid
mixture (10.1) shake well and stand for overnight. On the next day, heat the flask on the electric heating
plate for digestion until light yellow or colorless (if the color is dark, cool slightly and added a small amount of
nitric acid and continue digestion), Cool slightly, add 20 mL of water, and heated again to remove acid until
the volume of digestion solution is 0.5 mL-1.0 mL. After cooling down, add a small amount of water to
transfer to a 25 mL volumetric flask, added 0.5 mL of hydrochloric acid (10.2) and 0.5 mL of oxalic acid
solution (10.3), and mixed well. Then add1.00 mL of iron potassium cyanide solution (10.4). Then diluted
with water to 25 mL accurately, make up to the mark. Mix well. Stand for 30 min. Meanwhile, the reagent
blank is prepared.
Into 25 mL volumetric flasks, accurately added 0.00, 0.125, 0.25, 0.50, 0.75, 1.00 and 1.25 mL of standard
lead working solutions (10.8) respectively (lead concentration in each flask will be 0.0, 5.0, 10.0, 20.0, 30.0,
40.0 and 50.0 ng/mL respectively). After diluted with a small amount of water, the solution is added with 0.5
mL of hydrochloric acid (10.2) and 0.5 mL of oxalic acid (10.3), and mixed well. Add 1.0 mL of iron potassium
cyanide solution (10.4), diluted with water to 25 mL, and shaken to mix evenly. After staying for 30 min, the
solution is ready for determination.
12.3 Determination
Negative high voltage: 323 V, lead hollow cathode lamp current: 75 mA; atomizer: furnace temperature
750oC-800oC, furnace height: 8 mm; argon flow rate: carrier gas 800 mL/min; shielding gas: 1000ml/min;
duration for the addition of reducing agent: 7.0 s; reading time: 15.0 s; delay: 0.0 s; measurement method:
standard curve method; reading method: peak area; injection volume: 2.0 mL.
10 min-20 min, the measurement may begin. At first, the sample with a concentration of 0 in standard series
is introduced to the equipment continuously until the readings are stable. Then other samples in standard
series are introduced to the equipment and a standard curve is thus drawn. Finally, the samples, including
sample blank control and sample digestion solution, are introduced for the measurement. The lead content
of the sample is calculated on the basis of equation (2).
The lead content of the sample is calculated on the basis of equation (2).
�C1-C0�×V×1000
X= m×1000×1000
…………… (2)
In which,
Report the results in terms of arithmetic average from two independent measurements under the repeatable
conditions, and possess two significant digits.
The absolute difference between two independent measurement results obtained under repeatable
conditions is not allowed to exceed 10% of the arithmetic average of them.
15. Principle
After sample treatment, the lead ion forms a complex with DDTC under a certain pH value, and is introduced
to the atomic absorption spectrometer after extraction with 4-methylpentanone-2. After flame atomization,
the sample absorbs a resonance line at 283.3 nm with an absorption proportional to lead content. The
absorption is thus compared with standard series to yield quantitative results.
16.2 Ammonium sulfate solution (300 g/L): dissolve 30.0 g of ammonium sulfate [(NH4)2SO4] in water
and diluted with water to 100 mL.
16.3 Ammonium citrate solution (250g/L): Dissolve 25.0 g of ammonium citrate in water and diluted with
Copyright @ 2015 The Sovereign Group All Rights Reserved
74
water to 100 mL.
16.5 Sodium diethyl dithiocarbamate (DDTC) solution (50 g/L): dissolve 5 g of sodium diethyl
dithiocarbamate in water and diluted with water to 100 mL.
16.8 Standard lead solution: Operation is the same as those in 10.7 and 10.8. The standard working
solution has a lead concentration of 10 μg/mL.
16.9 Hydrochloride acid (1+11): add 10 ml HCl into 110 ml water, mix well
16.10 Phosphoric acid (1+10): add 10 ml phosphoric acid into 100 ml water, mix well
17.1 Atomic absorption spectrophotometer with flame atomizer; others are the same as those in 5.2, 5.3,
5.4, 5.5, 5.6 and 5.7.
18.1.1 Beverage and liquor: Weigh 10g-20 g (nearest to 0.01g) of well mixed sample in the beaker (The
alcohol should be removed from liquor by heating in water bath). The sample is heated on the electric
heating plate to evaporate a certain amount of water, add mixed acid (16.1). After full digestion, transfer
into a 50 mL volumetric flask and make up to the mark.
18.1.3 Cereal: remove impurities and dust, remove the husk if necessary, sieved by a 30-mesh sieve, and
mix evenly. Weigh 5g-10 g (nearest to 0.01g) in a 50 mL porcelain crucible, carbonized under low power, and
then transfer into muffle furnace, ash for 16 h in a temperature below 500oC. Take crucible out and cool to
room temperature. Add a small amount of mixed acid (16.1) and heated under low power so that the mixture
does not dry out. The process repeats until there is no charcoal grain in the residue. When the crucible cools
slightly, add l0 mL of hydrochloric acid (16.9) to dissolve it. Transfer into a 50 mL volumetric flask. Wash the
crucible repeatedly with water and transfer into the volumetric flask. Make up to the mark. This solution
should be freshly prepared each time
Prepare reagent blank with same volume of mixed acid and hydrochloric acid (16.9).
18.1.4 Vegetables, melon, fruit and beans: clean and dry the edible part, grind thoroughly and mix evenly.
Weigh 10 g-20 g of the sample (nearest to 0.01g) in the porcelain crucible, add 1 mL of phosphoric acid
(16.10), and carbonized under low power. The following procedure is the same as that after “and then
transferred into muffle furnace” in 18.1.3.
For the dairy products, after mixed evenly, take 50.0 mL of milk in the porcelain crucible, add phosphoric
acid (16.10), dry out in water bath, and carbonized under low power. The following procedure is the same as
that after “and then transferred into muffle furnace” in 18.1.3.
Depending on the sample condition, pipette 25.0 mL-50.0 mL of sample solution prepared from the
above-mentioned procedure and blank control solution in 125 mL separation funnels and diluted with water
to 60 mL. Add 2 mL of ammonium citrate solution (16.3) and 3-5 drops of bromothymol blue indicator (16.4).
Adjust pH with Ammonia solution (16.6) until solution color changes from yellow to blue. Add10.0 mL of
ammonium sulfate solution (16.2), 10 mL of DDTC solution (16.5), shaken to mix well. After stand for about 5
min, add 10.0 mL of MIBK (16.7), shaken vigorously for 1 min, stand for separation. Discard water layer, and
MIBK layer is released into a 10 mL graduated tube for use. Pipette 0.00, 0.25, 0.50, 1.00, 1.50 and 2.00 mL
(equivalent to 0.0, 2.5, 5.0, 10.0, 15.0 and 20.0 μg of lead respectively) of standard lead working solutions in
125 mL separatory funnels respectively. The following operation procedures are the same as those for the
sample.
18.3 Determination
18.3.1 Beverage, liquor and packaging material soaking solution can be introduced to the equipment for
determination directly after the extraction.
18.3.2 During the introduction of extraction solution sample, the acetylene gas flow can be reduced
appropriately.
18.3.3 Equipment reference conditions: Hollow cathode lamp current 8 mA; resonance line 283.3 nm; slot
0.4 nm; air flow rate 8 L/min; height of burner 6 mm.
(C1−C2)×V1×1000
X= m×V3/V2×1000
…………. (3)
In which,
m -- Weight or volume of the sample, g or mL; V1 -- Volume of sample extraction solution, mL;
The absolute value of difference between two independent measurement results obtained under repeatable
conditions is not allowed to exceed 20% of the arithmetic average of them.
21. Principle
After sample digestion, the lead ions form a red complex with disulfide hydrazone at pH 8.5-9.0 and then
dissolve in chloroform. Add Ammonium citrate, potassium cyanide and hydroxylamine hydrochloride to
eliminate the interference brought by iron, copper and zinc ions, compared with standard series to yield
quantitative lead content.
22.3 Phenol red indicator solution (1 g/L): Dissolve 0.10 g of phenol red in a small amount of ethanol for
many times, transfer into a 100 mL volumetric flask and diluted.
22.4 Hydroxylamine hydrochloride solution (200 g/L): weigh 20.0 g of hydroxylamine hydrochloride in 50
mL of water, add with 2 drops of phenol red indicator solution and adjust pH to 8.5-9.0 (after the color
changes from yellow to red, 2 more drops are added) with ammonia (1+1). Extract with Disulfide
hydrazone-chloroform solution (22.10) for several times, until the green color of chloroform layer does not
change any more. Wash twice with chloroform until chloroform layer is discarded, acidified water layer with
HCl (1+1) and diluted to 100 ml.
water, add 2 drops of phenol red indicator solution and adjust pH to 8.5-9.0 with ammonia (1+1). Extract with
Disulfide hydrazone-chloroform solution (22.10) for several times, each time use 10-20 ml, until the green
color of chloroform layer does not change any more. Discard chloroform layer. Water layer is washed twice
with chloroform. Each time use 5 ml chloroform. Chloroform layer is discarded, and water layer is diluted to
250 ml.
22.6 Potassium cyanide solution (100 g/L): Dissolve 10.0 g of potassium cyanide in water and diluted to
100 mL.
22.7.1 Inspection method: take 10 mL of chloroform, add 25 mL of freshly boiled water, shaken for 3 min,
and stand until full phase separation. Pipette 10 mL of water layer adds several drops of potassium iodide
solution (150 g/L) and starch indicator solution. After mixing, the solution shall not appear blue.
22.7.2 Treatment method: A certain amount of chloroform is washed by 1/10-1/20 equivalent volume of
sodium thiosulfate solution (200 g/L) and water, dehydrated by a small amount of anhydrous calcium
Copyright @ 2015 The Sovereign Group All Rights Reserved
77
chloride, and distilled. The initial 1/11 and last 1/10 of the distillate are discarded, and the middle part of it is
collected for use.
22.8 Starch indicator solution: dissolve 0.5 g of soluble starch in 5 mL of water, mixed well and slowly
poured into 100 mL of boiling water with agitation. After having boiled, the solution is allowed to cool down. It
should be prepared right before use.
22.10 Disulfide hydrazone chloroform solution (0.5 g/L): It should be stored in the refrigerator and, if
necessary, purified by the following method.
Weigh 0.5 g of ground fine disulfide hydrazone dissolve in 50 mL of chloroform. If it does not dissolve
completely, filtrate with filter paper, transfer into a 250 mL separatory funnel, and extract with ammonia
(1+99) for three times with a volume of 100 mL each time. Filtrate the extract with cotton into a 500 mL
separatory funnel, and adjusted pH lower than 7 with hydrochloric acid (1+1). In the acidic system, extract
disulfide hydrazone precipitates with chloroform for 2-3 times with a volume of 20 mL each time. Chloroform
layers are combined, washed twice with equivalent amount of water, and evaporate in 50oC water bath until
all chloroform is evaporated. Refined disulfide hydrazone is then stored in a desiccator with sulphuric acid
for future use. Or as an alternative, the disulfide hydrazone precipitate can be extracted by chloroform for
three times with a volume of 200, 200 and 100mL, respectively. The chloroform layers are then combined
and used as disulfide hydrazone solution.
22.11 Disulfide hydrazone working solution: dilute 1.0 mL of disulfide hydrazone solution To 10 mL with
chloroform and mixed evenly. In 1 cm cuvette, measure absorbance
(A) under 510 nm, adjust zero point with chloroform. Calculate the volume (V) of disulfide hydrazone solution
required for the preparation of 100 mL of disulfide hydrazone working solution with a transmittance of 70%
by formula 4.
………………………… (4)
22.13 Standard lead solution (1.0 mg/ml): Weigh 0.1598 g of lead nitrate and added 10 mL of nitric acid
(1+99). After full dissolving, transfer into a 100 mL volumetric flask and make up to the mark
22.14 Standard lead working solution (10.0 ug/ml): Pipette 1.0 mL of standard lead solution in a 100 mL
volumetric flask and make up to the mark.
23.1 Spectrophotometer
24.2.1.1 Grain, bean vermicelli, bean noodle, bean dry product, pastry, tea and other solid food with low
moisture content: weigh 5 g-10 g of crushed sample a 250 mL-500 mL nitrogen determination flask, wet the
samples with small amount of water, add several glass beads and 10 mL-15 mL of nitric acid, stand for a
moment and then heated slowly under low power. After the reaction slows down, cool down naturally. Along
the glass wall, and introduced 5 mL or l0 mL of sulphuric acid, heat again. After the liquid in the flask turns
brown, introduce nitric acid into the flask along the glass wall continuously until the organic matter
decomposes completely. The power is then increased until white smoke is generated. After all the white
smoke in the flask has gone, the regeneration of white smoke is an indication of complete digestion. This
solution should be transparent and colorless or slightly yellow. Cool down. (During operations, be careful to
avoid explosive boiling and explosion) Add 20 mL of water and heated until it boils to remove remaining nitric
acid until white smoke generated. This process is repeated two times. Cool down. Transfer into a 50 mL or
100 mL volumetric flask. Wash the nitrogen determination flask with water and transfer into the volumetric
flask. Cool down, diluted with water to the mark, and mixed evenly. In the final solution, 1ml is equivalent to
1g of sample and addition of 1ml sulphuric acid. Prepare reagent blank with the same amount of nitric acid
and sulphuric acid with the same operation steps
24.2.1.2 Vegetable and fruit: weigh 25.00 g or 50.00 g (nearest to 0.01g) of clean, homogenate sample in a
250 mL-500 mL nitrogen determination flask, and add several glass beads and 10 mL-15 mL of nitric acid.
The following procedure is the same as that after “stand for a moment” in 24.2.1.1. But in the final solution
here, 10ml is equivalent to 5g of sample and addition of 1ml sulphuric acid.
24.2.1.3 Sauce, soy sauce, vinegar, cold drink, tofu, fermented bean curd and sauce preserved vegetable:
weigh 10g or 20g (nearest to 0.01g) of sample or pipette 10.0 mL or 20.0 mL of liquid sample in a 250
mL-500 mL nitrogen determination flask, added several glass beads and 5 mL-15 mL of nitric acid. The
following procedure is the same as that after “stand for a moment” in 24.2.1.1. But in the final solution here,
10ml is equivalent to 2g or 2 ml of sample
24.2.1.4 Alcohol beverage or carbon dioxide beverage: pipette 10.00 mL or 20.00 mL of sample in a 250
mL-500 mL nitrogen determination flask, add several glass beads, heated under low power to remove
ethanol or carbon dioxide, then add 5 mL-10 mL of nitric acid, and mix evenly. The following procedure is the
same as that after “stand for a moment” in 24.2.1.1. But in the final solution here, 10ml is equivalent to 2 ml
of sample
24.2.1.5 Food with high sugar content: weigh 5g or 10 g (nearest to 0.01g) of sample in a 250 mL-500 mL
nitrogen determination flask, add a little water to wet, add several glass beads and 5 mL-10 mL of nitric acid,
and shaken to mix well. Into the flask slowly introduce 5 mL or 10mL of sulphuric acid. After the reaction
slows down and the bubbling stops, lowly heat with low power (sugar is subject to carbonize) and add more
nitric acid continuously along the glass wall. After all bubbles disappear, the power is increased until the
organic matter decomposes completely and white smoke is generated. This solution should be transparent
and colorless or slightly yellow. It is then allowed to cool down. The following procedure is the same as that
after “add 20 mL of water and heated until it boils” in 24.2.1.1.
24.2.1.6 Aquatic product: weigh 5 g or 10 g (nearest to 0.01g, lower for marine algae and shellfish)
homogenized the edible part of the sample in a 250 mL-500 mL nitrogen determination flask, added glass
beads and 5 mL-10 mL of nitric acid, and mixed evenly. The following procedure is the same as that after
“Along the glass wall introduced 5 mL or l0 mL of sulphuric acid” in 24.2.1.1.
24.2.2.1 Grain and other foods with low moisture content: weigh 5 g of the sample (nearest to 0.01g) in a
quartz or porcelain crucible, heated until it is carbonized, transfer into muffle furnace to ash 3 h at 500oC.
After cooling down, the crucible is taken out, add nitric acid (1+1) to wet the ash, heated with low power to
evaporate water, burnt for 1 h at 500oC, then cool down. Then take out the crucible, add 1 mL of nitric acid
(1+1) and heat to dissolve the ash content. Transfer into a 50 mL volumetric flask. Wash the crucible into the
volumetric flask. Make up to the mark. Mixed evenly for use.
24.2.2.2 Food with high moisture content or liquid sample: weigh 5.0 g or 5.0 mL of the In an evaporating
dish, heat in water bath to evaporate water. The following procedure is the same as that after “heated until it
is carbonized” in 24.2.2.1.
24.3 Determination
24.3.1 Pipette 10.0 mL of sample solution after digestion and the same volume of reagent blank control
solution in 125 mL separatory funnels and diluted with water to 20 mL respectively.
24.3.2 Pipette 0, 0.10, 0.20, 0.30, 0.40 and 0.50 mL (equivalent to 0.0, 1.0, 2.0, 3.0, 4.0
and 5.0 μg of lead) of standard lead working solutions in 125 mL separatory funnels, and diluted with nitric
acid (1+99) to 20 mL. Add 2.0 ml mmonium citrate solution (200 g/L), 1.0 mL of hydroxylamine hydrochloride
solution (200 g/L) and 2 drops of phenol red indicator solution into the sample digestion solution, reagent
blank control solution and standard lead solution. Adjusted by ammonia (1+1) until the color turns red. Add
2.0 mL of potassium cyanide solution (100 g/L), mixed well, then add 5.0 mL of disulfide hydrazone working
solution, and shaken vigorously for 1 min. Stand to full phase separation. After filtration with degreased
cotton, pipette a certain amount of sample from chloroform layer into a 1 cm cuvette. Chloroform is used for
the zero point adjustment and absorbance is measured at a wavelength of 511 nm. After subtracted by the
absorbance of sample with a concentration of 0, each absorbance is used for the preparation of standard
curve or for the calculation of unary regression equation. The sample absorbance is compared with standard
curve.
(𝑚𝑚1−𝑚𝑚2)×1000
X= 𝑚𝑚3×𝑉𝑉1/𝑉𝑉1×1000
…………. (5)
In which,
The absolute difference between two independent measurement results obtained under repeatability
conditions is not allowed to exceed 11% of the arithmetic average of them.
27. Principle
After sample digestion, in acidified circumstance (pb2+) and I- forms PbI 2-complex ions. The complex
possesses electrical activity and generates reduction current on dropping mercury electrode. The peak
current varies linearly with lead content and is compared with standard series to yield quantitative lead
content.
28.1 Base solution: dissolve 5.0 g of potassium iodide, 8.0 g of potassium sodium tartrate and 0.5 g of
ascorbic acid in a 500 mL beaker with 300 mL of water, add 10 mL of hydrochloric acid, transfer into a 500
mL volumetric flask and make up to the mark (it is stored in refrigerator and can be preserved for 2 months).
28.2 Lead standard stock solution (1.0 mg/ml): Weigh accurately 0.1000 g of lead (purity 99.99%) in a
beaker, add 2 mL of nitric acid solution (1+1), and heated to dissolve. After cooling down, the solution is
transferred into a 100 mL volumetric flask and diluted with water to 100 mL and mixed evenly.
28.3 Lead standard working solution(10.0ug/ml): Prior to the use of lead solution, pipette
1.00 mL of lead standard stock solution in a 100 mL volumetric flask, make up to the mark and mixed evenly.
28.4 Mixed acid: Nitric acid-perchloric acid (4+1). 80 mL of nitric acid is added with 20 mL of perchloric
acid and mixed evenly.
Single-sweep polarography (SSP). Initial potential: -350 mV; final potential: -850 mV; sweep speed: 300
mV/s; three electrodes, second derivative, stationary time: 5 s; appropriate measurement range. The peak
current of lead is recorded at the peak potential of -470 mV.
Pipette 0, 0.05, 0.10, 0.20, 0.30 and 0.40 mL (equivalent to 0, 0.5, 1.0, 2.0, 3.0 and
Remove impurities, sieve with 20 mesh sieve and grind for the low moisture content samples like grain, bean
ect. Homoginizing the high moisture content samples like vegetable, fruit, fish and meat ect. And store in
plastic bottle
30.3.1 Sample treatment (including grain, bean, pastry, tea and meat, except for salt and white sugar):
Weigh 1 g-2 g of sample in a 50 mL flask, add 10 mL-20 mL of mixed acid, and soaked overnight with a
cover on the top. Then the flask is heated by the universal electric furnace with an electronic regulator with
low power. If the color of digestion solution turns darker gradually and appears dark brown, the flask is
taken out from the universal electric furnace to cool down, add an appropriate amount of
nitric acid, and heat again to continue digestion. When the color of the solution no longer dark, starts to
appear transparent and colorless or slightly yellow, and emits white smoke, the solution can be heated with
high power to remove residual acid solution. When most of the liquid has evaporated, the system should be
heated with low power to yield a white residue, which will be used for determination. Meanwhile, the reagent
is used to provide blank control.
30.3.2 Salt and white sugar: weigh 2.0 g of the sample in a beaker for use.
Weigh 2 g of sample (nearest to 0.1g) in a 50 mL flask (the sample containing ethanol or carbon dioxide
should be heated in 80oC water bath to remove them), add 1 mL-10 mL of mixed acid, heated by the
universal electric furnace with an electronic regulator at low power. The following procedure is the same as
that after “Sample treatment” in 30.3.1. The sample is ready for the determination.
Add 10.0 mL of base solution into the above sample and reagent blank control bottle, respectively, to
dissolve the residue. Transferred into the electrolytic cell. The following procedure is the same as that after
“Preparation of standard curve” in 30.2. Record the peak currents. Calculate the lead concentration in the
standard curve.
The lead content in the sample is calculated on the basis of equation (6).
(𝐴𝐴−𝐴𝐴0)×1000
X= 𝑚𝑚×1000
………… (6)
In which,
A -- Weight of lead in the sample solution read from standard curve, μg;
A0 -- Weight of lead in the reagent blank control solution read from standard curve, μg;
Report the mean of two independent results under repeatability condition with two
significant digits.
The absolute difference between two independent measurement results obtained under repeatability
conditions is not allowed to exceed 5.0% of the arithmetic average of them.
33. Other
The detection limit: graphite furnace atomic absorption spectrometry: 0.005 mg/kg; hydride generation
atomic fluorescence spectrometry: 0.005mg/kg for solid and 0.001mg/kg for liquid; flame atomic absorption
spectrometry: 0.1mg/kg; single-sweep polarography: 0.25 mg/kg ; disulfide hydrazone colorimetry: 0.085
mg/kg.
A.1 Polarograms of lead in reagent blank control and standard lead solution are shown in Figures A.1
GB 5009.123-2014
Compared to GB/T 5009.123-2003, this standard maintains the following major changes:
- Name of the standard is modified into “ National Standard for Food Safety - Determination of
Chromium in Foods”;
1. Scope
This standard specifies the determination of chromium in foods by graphite furnace atomic absorption
spectrometric method.
2. Principle
After the specimen digests, the graphite furnace atomic absorption spectrometric method will be adopted to
measure the absorbance at 357.9 nm. Compare the absorbance to limit of qualification of the standard
series solution under the given concentration range.
Note: except otherwise specified, all reagents used in this method are guaranteed pure reagents and water
are Class II water specified in GB / T6682.
3.1 Reagents
3.2.1 Nitric acid solution (5 + 95): measure and take 50 ml of nitric acid, slowly pour it into 950 ml of water,
and mix it well.
3.2.2 Nitric acid solution (1 + 1): measure and take 250 ml of nitric acid, slowly pour it into 250 ml of water,
and mix it well.
3.2.3 Ammonium dihydrogen phosphate solution (20 g/l): weigh and take 2.0 g of ammonium dihydrogen
phosphate, dissolve it into water and dilute it to 100 ml, and mix it well.
Potassium dichromate (K2Cr2O7): purity> 99.5%, or reference materials certified by and granted with
reference materials certificate by the State.
3.4.1 Chromium standard stock solution: weigh 1.4315 g (accurate to 0.0001 g) of the reference
material potassium dichromate (110℃ , baked for 2h), dissolve it into water and transfer it into 500 ml
volumetric flask, dilute it with nitric acid solution (5+ 95) to the mark, and mix it well. This solution contains
1.000 mg of chromium per milliliter. Chromium standard stock solution certified by the State and granted with
reference material certificate shall be purchased.
3.4.2 Chromium standard use solution: dilute chromium standard use solution by nitric acid solution (5 +
95) progressively till the content of chromium per ml is 100 ng.
3.4.3 Preparation of standard series solutions: imbibe and take respectively 0 ml, 0.500 ml, 1.00 ml, 2.00
ml, 3.00 ml, and 4.00 ml of chromium standard use solution (100 ng/ml) and tranfer it to 25 ml volumetric
flask; dilute it with nitric acid solution (5 + 95) to the mark, and mix it well. Chromium content per milliliter in
each volumetric flask shall be 0 ng, 2.00 ng, 4.00 ng, 8.00 ng, 12.0 ng, and 16.0 ng respectively. Or, graphite
furnace automatic specimenr might be adopted for automatic preparation.
Note: all glassware applied shall be soaked in nitric acid solution (1 + 4) for 24h or above, washed with water
repeatedly, and finally washed and rinsed with deionized water.
4.1 Atomic absorption spectrometer, equipped with graphite furnace atomizer, and attached with chromium
hollow cathode lamp.
5. Analytical procedures
5.1.1 Crush and load grains, beans and other foodstaffs into a clean container after foreign matters are
removed, and use them as specimen. Seal and label clearly; specimens shall be stored at room
temperature.
5.1.2 Fresh specimens with higher content of water such as vegetables, fruits, fish, meat and eggs shall
be directly refined into homogenized solution, loaded into clean container and used as specimen; seal and
label clearly; specimen shall be stored in refrigerator freezer.
Accurately weigh and take 0.2g~0.6g (accurate to 0.001g) of specimen and transfer it into microwave
digestion tank; add 5 ml nitric acid; digest specimen as per microwave digestion procedure (please refer to
A.1 for microwave digestion conditions); take out the digestion tank after it cools down; clear up acid to 0.5
ml~1.0 ml on electric hot plate under the temperature of 140℃ ~160℃ . After digestion tank cools down,
transfer the digestion solution to 10 ml volumetric flask, wash digestion tank by a small amount of water for
2~3 times; combined the washing liquid, dilute it by water to the mark; conduct reagent blank test at the
same time.
Weigh and take 0.5 g~3 g (accurate to 0.001 g) of specimen and transfer it into digestive tract; add 10 ml of
nitric acid and 0.5 ml of perchloric acid; digest on the adjustable electric furnace (reference conditions: 120℃ ,
kept for 0.5h~1h, heated up to 180℃for 2h~4h, and heated up to 200℃ ~220℃ ). If the digestion liquid is brown
in color, add nitric acid into it until white smoke rises; digestion liquid shall be colorless, transparent or
slightly yellowish; take out the digestive tract, cool it down and dilute it by water to 10 ml. At the same
conduct the blank test for the reagent.
Accurately weigh and take 0.3 g~1 g (accurate to 0.001 g) of specimen and transfer it into digestion tank;
add 5 ml of nitric acid; replace the inner cover; tighten the stainless steel jacket and put it into the constant
temperature oven; maintain it for 4h~5h at 140℃ ~160℃ . Cool it down naturally to room temperature within the
constant temperature oven; slowly loosen the outer tank and take out the inner digestion tank; place it onto
the adjustable electric hot plate and clear up acid to 0.5 ml~1.0 ml at 140℃ ~160℃ . After cooling, transfer the
digestion liquid into a 10 ml volumetric flask, and wash the inner tank by a small amount of water for 2~3
times. Combine the wash lotion into the volumetric flask and dilute it by water to the mark; at the same,
conduct the blank test for the reagent.
Weigh and take 0.5 g~3 g (accurate to 0.001 g) of specimen and transfer it into a crucible; simmer till it is
carbonized and smokeless; transfer it into a muffle furnace; maintain it for 3h~4h at 550℃ . Take it out and
cool down. For specimen that is not fully ashed, add a few drops of nitric acid, simmer, and evaporate
carefully; then transfer it into high temperature furnace of 550℃and continue ashing treatment for 1h~2h till
the specimen is lime-like; take it out from the high-temperature furnace and cool down; dissolve it by nitric
acid solution (1 + 1) and dilute it with water to 10 ml; at the same time conduct the blank test for the reagent.
5.3 Determination
Calibrate to the optimal state as per performance of the respective instrument. For reference conditions,
please refer to A.2.
Take respectively 10 µl (you can select the best injection volume as per the instrument applied) of standard
series solution working solution bottom up in terms of concentration, inject it into graphite tube, and measure
its absorbance after it is being atomized; take concentration as the horizontal axis and absorbance vertical
axis and map the standard curve.
Under the same experimental conditions under which the standard solution is determined, take respectively
10 µl of the blank solution and specimen solution (the best injection volume might be subject to the
instrument applied); inject them into graphite tube; measure its absorbance value after it is being atomized;
compare to the limit of quantification of the standard series solution.
Inject 5 μl (the best injection volume can be subject to the instrument applied) of ammonium dihydrogen
phosphate solution (20.0 g/l) into the interferred specimen (preparation process of the standard series
solution specified in 5.3.3 shall be followed).
For calculation of chromium content in the specimen, please refer to Formula (1):
In the formula:
c- determination of chromium content in the specimen solution, in nanogram per milliliter (ng/ml);
When the analysis result ≥1 mg/kg, keep a three-digit valid number; when the analysis result < 1mg/kg, keep
a two-digit valid number.
7. Precision
Absolute difference between two independent determination results obtained under the repeatability
conditions shall not exceed 20% of their arithmetic mean.
8. Others
Calculate by 0.5 g of the specimen weighed and dilute it to 10 ml; the detection limit in such case shall be
0.01 mg/kg, and the limit of quantification 0.03 mg/kg.
A.2 Please refer to Table A for reference conditions for microwave digestion
Step Power (1,200w), change/% Set temperature / ℃ Warm-up time /min Holding time /min
1 0~80 120 5 5
2 0~80 160 5 10
3 0~80 180 5 10
A.3 For reference conditions of graphite furnace atomic absorption spectrometry, please refer to Table
A.2.
Wavelength/n Atomization
Element Slits /nm Lamp current /mA Drying /(℃
/s) Ashing (℃
/s)
m (℃/s)
(85~120)/(40~
Chromium 357.9 0.2 5~7 900/(20~30) 2,700(4~5)
50)
GB 5009.15-2014
- The title of the standard is revised to “National food safety standard determination
of cadmium in foods”
- Method 2 Atomic absorption spectrometry, Method 3 Colorimetry, and Method 4 Atomic fluorescence
spectrometry, are deleted.
1 Scope
This standard specifies a graphite furnace atomic absorption spectrometric method for determination of
cadmium in all kinds of food.
2 Principle
The test sample is ashed or digested with acid whereupon a specific amount of the digest is injected into
the atomic absorption spectrophotometer graphite furnace and electrothermally atomised, absorbing the
228.8 nm resonance line; within a specific concentration range the absorbance is directly proportional to
cadmium content, which is determined by the standard curve method.
Note 1: Unless otherwise indicated, all reagents used in this method are analytically pure; the water is
Class 2 water specified in GB/T 6682.
Note 2: All glassware must be soaked in nitric acid solution (1+4) for not less than 24 h, rinsed repeatedly
with water, and finally rinsed with deionised water and dried.
3.1 Reagents
3.2.1 Nitric acid solution (1%): Add 10.0 mL of nitric acid to 100 mL of water and dilute to 1,000 mL.
3.2.2 Hydrochloric acid solution (1+1): Slowly add 50 mL of hydrochloric acid to 50 mL of water.
3.2.3 Mixed nitric acid-perchloric acid solution (9+1): Mix 9 parts of nitric acid with 1 part of perchloric
acid.
3.2.4 Ammonium dihydrogen phosphate solution (10 g/L): Weigh out 10.0 g of ammonium dihydrogen
phosphate, dissolve with 100 mL of nitric acid solution (1%) and transfer quantitatively to a 1,000 mL
volumetric flask; make up to the graduation mark with nitric acid solution (1%).
3.4.1 Cadmium standard stock solution (1,000 mg/L): Accurately weigh 1 g (accurate to 0.0001 g) of
the standard sample of cadmium metal into a small beaker, dissolve with 20 mL of hydrochloric acid
solution (1+1) added in portions, then add 2 drops of nitric acid; transfer to a 1,000 mL volumetric flask,
make up to the graduation mark with water and mix. Alternatively, purchase nationally authenticated
reference material holding a reference material certificate.
3.4.2 Cadmium standard intermediate working solution (100 ng/mL): Pipette 10.0 mL of the cadmium
standard stock solution into a 100 mL volumetric flask and make up to the graduation mark with nitric acid
solution (1%); dilute repeatedly this way to obtain a standard intermediate working solution containing
100.0 ng of cadmium per millilitre.
3.4.3 Standard curve working solutions: Accurately pipette 0 mL, 0.50 mL, 1.0 mL,
1.5 mL, 2.0 mL and 3.0 mL of the cadmium standard intermediate working solution into 100 mL volumetric
flasks and make up to the graduation mark with nitric acid solution (1%) to obtain a standard series of
solutions containing cadmium 0 ng/mL, 0.50 ng/mL, 1.0 ng/mL, 1.5 ng/mL, 2.0 ng/mL and 3.0 ng/mL,
respectively.
4.8 Microwave digestion system: Fitted with polytetrafluoroethylene or other suitable pressure vessel.
5 Analytical procedure
5.1.1 Dry test samples: For grain and pulses, exclude foreign matter; for nuts remove foreign matter
and shells. Grind to a homogeneous sample of particle size not greater than 0.425 mm. Store in a clean
plastic bottle and label clearly; hold ready for use at room temperature, or under storage conditions
consistent with the sample.
5.1.2 Fresh (wet) test samples: Vegetables, melons, meats, fish, eggs, etc, are homogenised with a
food processor or milled to a homogenate; store in a clean plastic bottle, label clearly, and hold in a
refrigerator at -16°C to -18°C pending use.
Copyright @ 2015 The Sovereign Group All Rights Reserved
95
5.1.3 Liquid test samples: Hold under storage conditions consistent with the sample pending use.
Degas gas-containing samples before use.
The sample may be digested using any one of the following methods according to laboratory
circumstances. Sample homogeneity should be assured in weighing.
a) Digestion with a pressure digestion vessel: Weigh 0.3 g - 0.5 g (accurate to 0.0001
g) of the dry test sample or 1 g - 2 g (accurate to 0.001 g) of the fresh (wet) test sample into the
polytetrafluoroethylene liner vessel, add 5 mL of nitric acid and soak overnight. Then add 2 mL - 3 mL of
hydrogen peroxide solution (30%) (the total volume may not exceed one third of the vessel capacity).
Cover the liner vessel and tightly screw on the stainless steel case; place in the thermostatic drying
cabinet, hold at 120°C-160°C for 4 h -6 h, and allow to cool naturally to room temperature inside the
cabinet. After opening the vessel, heat to near dryness to drive off acid. Wash the digest into a 10 mL or
25 mL volumetric flask, rinse the liner vessel and inner cover 3 times with a little nitric acid solution (1%),
combine the washings in the volumetric flask, make up to the graduation mark with nitric acid solution (1%),
and mix ready for use. Run a reagent blank test in parallel.
b) Microwave digestion: Weigh out 0.3 g - 0.5 g (accurate to 0.0001 g) of the dry test sample or 1 g - 2 g
(accurate to 0.001 g) of the fresh (wet) test sample, place in the microwave digester, and add 5 mL of nitric
acid and 2 mL of hydrogen peroxide. The microwave digestion programme can be adjusted to the provide
the optimum conditions for the instrument model. On completion of digestion, the digestion vessel is left to
cool and then opened; the digest is colourless or pale yellow. Heat to near dryness to drive off acid, wash
the digestion vessel 3 times with a little nitric acid solution (1%), transfer the solution to a 10 mL or 25 mL
volumetric flask, make up to the graduation mark with nitric acid solution (1%), and mix ready for use. Run
a reagent blank test in parallel.
c) Wet digestion: Weigh 0.3 g - 0.5 g (accurate to 0.0001 g) of the dry test sample or 1 g - 2 g (accurate
to 0.001 g) of the fresh (wet) test sample into a conical flask, introduce several glass beads, add 10 mL of
nitric acid-perchloric acid mixture (9+1), cover and soak overnight; with a small funnel added, digest on the
electric hotplate. If the digest turns black-brown, add further nitric acid until white fumes are given off and
the digest is colourless and transparent or tinged faint yellow, and leave to cool. Then wash the digest into
a 10 mL - 25 mL volumetric flask, rinse the conical flask 3 times with a little nitric acid solution (1%),
combine the washings in the graduated flask make up to the graduation mark with nitric acid solution (1%),
and mix ready for use. Run a reagent blank test in parallel.
d) Dry ashing: Weigh 0.3 g - 0.5 g (accurate to 0.0001 g) of the dry test sample, 1 g - 2 g (accurate to
0.001 g) of the fresh (wet) test sample or 1 g - 2 g (accurate to 0.001 g) of the liquid sample into a
porcelain crucible; gently carbonise in the adjustable temperature electric oven until smoke is no longer
emitted, then transfer to the muffle furnace, ash for 6 h - 8 h at 500°C and cool. If a sample has not been
completely ashed, add 1 mL of mixed acid and heat gently on the adjustable temperature electric oven;
once the mixed acid has evaporated to dryness, transfer the sample back into the muffle furnace and
continue ashing at 500°C for 1 h - 2 h until fully digested and the ash is greyish white or grey. Leave to cool,
dissolve the ash with nitric acid solution (1%), transfer the sample digest to a 10 mL or 25 mL volumetric
flask, wash the porcelain crucible 3 times with a little nitric acid solution (1%) , and combine the washings
in the volumetric flask; make up to the graduation mark with nitric acid solution (1%) and mix ready for use.
Run a reagent blank test in parallel.
Adjust instruments to the optimum conditions for the model used. The reference operating conditions for
the atomic absorption spectrophotometer (with graphite furnace and cadmium hollow cathode fitted) are
as follows:
Wavelength 228.8 nm, slit 0.2 nm - 1.0 nm, lamp current 2 mA - 10 mA, drying temperature 105°C,
drying time 20 s;
Proceeding from low to high concentration, inject into the graphite furnace 20 µL of each standard curve
working solution; measure the absorbance, plot the standard curve with the concentration of the standard
curve working solution as horizontal coordinate and the corresponding absorbance as vertical coordinate,
and find the simple linear regression equation for the relation of absorbance versus concentration.
The standard series solutions should be cadmium standard solutions of no fewer than 5 different
concentrations, and the coefficient of correlation should not be less than 0.995. If an automated sample
injection unit is available, programmed dilution may be used to generate the standard series.
Under the same experimental conditions as in examination of the standard curve working solutions,
pipette 20 µL of the sample digest (the optimum sample volume for the instrument used may be chosen),
inject it into the graphite furnace, and measure the absorbance. Substitute into the simple linear
regression equation of the standard series to find the content of cadmium in the sample digest, using no
fewer than two replicates. If the results of measurement fall outside the range of the standard curve, make
the measurements again after dilution with nitric acid solution (1%).
For test samples subject to interference, inject the sample digest into the graphite furnace with 5 µL of
ammonium dihydrogen phosphate matrix modifier (10 g/L). The same amount of matrix modifier as in
examination of the sample must be added when the standard curve is plotted.
Calculate the cadmium content of the test sample from Equation (1).
(𝐶𝐶1−𝑐𝑐0)×𝑉𝑉
X= ………………(1)
𝑚𝑚×1000
Where:
Copyright @ 2015 The Sovereign Group All Rights Reserved
97
X - Cadmium content of test sample in units of milligrams per kilogram or milli- grams per litre (mg/kg or
mg/L);
C1 - Cadmium content of the test sample digest in units of nanograms per millilitre (ng/mL);
C0 - Cadmium content of the blank solution in units of nanograms per millilitre (ng/mL);
V - Total final volume of the test sample digest in millilitre units (mL);
M - Test sample mass or volume in units of grams or millilitres (g or mL); 1000 conve rs ion
The arithmetic mean of the results of two independent determinations obtained under repeatable conditions
is presented, retaining two significant digits.
7 Precision
The absolute difference between the results of two independent determinations obtained under repeatable
conditions shall not exceed 20% of the arithmetic mean.
8 Other particulars
The limit of detection of the method is 0.001 mg/kg and the limit of quantitation is 0.003 mg/kg.
GB 5009.16-2014
Compared to GB/T 5009.16-2003, this standard maintains the following major changes:
- Name of the standard is modified into “National Standard for Food Safety - Determination of Tin in
Foods”.
1. Scope
This standard specifies the determination of hydride of tin in foods by atomic fluorescence spectroscopy
and phenylfuoron colorimetry.
This standard applies to determination of tin in canned solid foods, canned drinks, canned jams, and
canned infant formula and supplementary foods.
2. Principle
Tin hydride (SnH4) will be generated under the effects of sodium borohydride after the specimen digests and
will be carried into the atomizer by the carrier gas for atomization. Illuminated by tin hollow cathode lamp, the
tin atom in ground state will be activated to high-energy state and fluorescence of characteristic wavelengths
will be emitted when such tin atoms are deactivated and return to the ground state. The fluorescence
intensity of tin atoms is proportional to its tin content. Compare the limit of quantification to that of the
standard series solution.
Note: except otherwise stated, reagents applied herein shall be the analytical pure reagents, and the water
be Class II water specified in GB/T6682.
3.1 Reagents
3.2.1 Nitric acid - perchloric acid mixture solution (4 + 1): measure and take 400 ml and 100 ml nitric acid
perchlorate and mix them well.
3.2.2 Sulfuric acid solution (1+9): measure and take 100 ml sulfuric acid and pour it into 900 ml of water,
and mix them well.
3.2.4 Sodium hydroxide solution (5.0 g/l): weigh and take 5.0 g of sodium hydroxide and dissolve it in
1,000 ml of water.
3.2.5 Sodium borohydride solution (7.0 g/l): weigh and take 7.0 g of sodium borohydride, and dissolve it
in sodium hydroxide solution for extemporaneous preparation.
Reference material Tin metal (Sn), reference material with a purity of 99.99% or reference material certified
and granted by the State with reference material certificate.
3.4.1 Tin standard solution (1.0 mg/ml): weigh and take 0.1 g (accurate to 0.000 1 g) Tin metal reference
material; place it into a small beaker; add 10.0 ml of sulfuric acid and cover it by pan; heat it up till tin is
fully dissoved; remove the pan; continue the heating till thick white smoke occurs; cool it down and
slowly add 50 ml of water; transfer it into a 100 ml flask; wash the beaker by sulfuric acid solution (1 +9)
repeatedly; pour solution into volumetric flask and dilute it to the mark; mix it well.
3.4.2 Standard tin use solution (1.0 μg/ml): imbibe and take 1.0 ml tin standard solution and transfer it into
a 100 ml volumetric flask; dilute it with sulfuric acid solution (l +9) to the mark. The concentration of this
solution is 10.0 μg/ml. Imbibe and take 10.0 ml of this solution and transfer it in 100 ml flask, and dilute it with
sulfuric acid solution (1 + 9) to the mark.
5. Analytical procedures
For canned foods, weigh and take edible contents of foods and make them into homogenized or even
powder.
5.2.1 Weigh and take 1.0 g ~ 5.0 g specimen and transfer it into the conical flask; add 20.0 ml nitric acid -
perchloric acid mixed solution (4 + 1); add 1.0 ml of sulfuric acid and 3 glass beads, and let it stand overnight.
On the following day, place it onto electric hot plate to heat up and dissolve it; if the acid is too small, it is ok
to supplement an appropriate amount of nitric acid; disgest continuously till white smoke rises; take it down
and cool it down when the liquid volume is close to 1 ml; transfer by water the digested specimen into the 50
ml volumetric flask, dilute it by water to mark; shake it up for use. At the same time, conduct blank test (if tin
content in the specimen solution goes beyond the range indicated by the standard curve, then dilute it with
Copyright @ 2015 The Sovereign Group All Rights Reserved
102
water and supplement sulfuric acid, so that the concentration of the sulfuric acid solution with constant
volume will be identical with that of the standard series solution).
5.2.2 Take 10.0 ml of the specimen diluted to mark in 5.2.1 and transfer it into 25 ml colorimetric tube; add
3.0 ml of sulfuric acid solution (l + 9); add 2.0 ml of thiourea (150 g/l) + ascorbic acid (l50 g/l); mix them well
and then dilute it with water to 25 ml; and shake it up for use.
— Delay time:1s;
— Reading time:15s;
Standard curve: respectively imbibe standard tin use solution 0.00 ml, 0.50 ml, 2.00 ml, 3.00 ml, 4.00 ml,
5.00 ml and transfer them to 25 ml colorimetric tubes; add sulfuric acid solution (1 + 9) 5.00 ml, 4.50 ml, 3.00
ml, 2.00 ml, 1.00 ml, and 0.00 ml into it; add 2.0 ml thiourea (150 g/l) + ascorbic acid (150 g/l) mixture
solution; dilute it with water to 25 ml. The concentration of the standard series solution: 0ng / ml, 20 ng / ml,
80 ng / ml, l20 ng / ml, 160 ng / ml and 200 ng / ml respectively.
Set up the optimal measurement conditions of instrument as per 5.3 and set the appropriate parameter
points as per model of instrument and the workstations applied; ignite and preheat up the instrument;
determine the standard curve and specimen solution after it is preheated for 30 minutes.
In the formula:
C1- determined concentration of digested specimen solution, in nanogram per milliliter (ng / ml);
C0- concentration of blank digestion solution of the specimen, in nanogram per milliliter (ng / ml);
V2- volume of specimen digestion solution taken for purpose of determination, in milliliter (ml);
When the calculated result is smaler than 10 mg/kg, the hundredth behind the decimal shall be kept; when
the calculated result is bigger than less than 10 mg/kg, a two-digit valid number shall be retained.
7. Precision
Absolute difference between two independent determination results obtained under the repeatability
conditions shall not exceed 10% of their arithmetic mean.
8. Others
When the specimen volume is 1.0g, the limit of quantification under this method shall be 2.5 mg/kg.
9. Principle
After the specimen is digested, tetravalent tin ions and phenylfluorone form sparingly soluble orange-red
complex in weak acid solution, and compares limit of quantification to that of the standard series solution in
the presence of protective colloid.
Note: except otherwise stated, the reagents applied under this method are analytical pure reagents and
water is Class III water specified under GB / T6682.
10.1 Reagents
Copyright @ 2015 The Sovereign Group All Rights Reserved
104
10.1.1 Tartaric acid (C4H4O6H2).
10.2.1 Tartaric acid solution (100 g/l): weigh and take 100 g of tartaric acid and dissolve it into 1l of water.
10.2.2 Ascorbic acid solution (10.0 g/l): weigh and take 10.0 g of ascorbic acid and dissolve it into 1l of
water for purpose of extemporaneous preparation.
10.2.3 Animal glue solution (5.0 g/I): weigh and take 5.0 g of animal glue and dissolve it into 1l of water for
purpose of extemporaneous preparation.
10.2.4 Ammonia solution (1+1): weigh and take 100 ml of ammonia water and pour it into 100 ml of water,
and mix them well.
10.2.5 Sulfuric acid solution (1+9): weigh and take 10 ml of sulfuric acid, mix and pour it slowly into 90 ml
of water and shake them up.
10.2.6 Phenylfluorone solution (0.1 g/l): weigh and take 0.01g (accurate to 0.001 g) of phenylfluorone, add
an iota of methanol and a few drops of sulfuric acid to dissolve it, with the methanol being diluted to 100 ml.
10.2.7 Phenolphthalein indicator solution (10.0 g/l): weigh and take 1.0 g of phenolphthalein and dissolve it
by ethanol to 100 ml.
Refernence material of Tin metal (Sn), refernence material with a purity of 99.99% or refernence material
certified and granted by the State with refernence material certificate.
10.4.1 Tin standard solution (1.0 mg/ml): weigh and take 0.1 g (accurate to 0.0001 g) of Tin metal; transfer
it into a small beaker; add 10 ml of sulfuric acid; cover it with a pan; heat it up till the tin is completely
dissolved; remove the pan; continue to heat until thick white smoke occurs; cool it down slowly; add 50 ml of
water and transfer it into 100 ml of volumetric flask; wash the beaker by sulfuric acid solution (1 + 9)
repeatedly; pour the wash lotion into flask; dilute it to mark and mix it well.
11.1 Spectrophotometer.
12.1.2 Imbibe and take 1.00 ml ~ 5.00 ml specimen digestion solution and the same amount of reagent
blank solution; transfer them into 25 ml colorimetric tube, respectively; add 0.5ml of tartaric acid solution
(100 g/l) and 1 drop of phenolphthalein indicator solution (100 g/l) into specimen digestion solution and
reagent blank solution and mix it well; add ammonia solution (1 + 1) to each of them till it becomes pink; add
3.0 ml of sulfuric acid solution (1 + 1), 1.0 ml of animal glue solution (5.0 g/l) and 2.5 ml of ascorbic acid
solution (l 0.0 g/l); add water till the volume is 25 ml and mix it well; then add 2.0 ml of phenylfuoron solution
(0.1 g/l) and mix it well; stand for 1h and measure.
Imbibe and take 0.00 ml, 0.20 ml, 0.40 ml, 0.60 ml, 0.80 ml and 1.00 ml of tin standard solution (equivalent to
0.00 μg, 2.00 μg, 4.00 μg, 6.00 μg, 8.00 μg, and 10.00 μg of tin); transfer it into 25 ml colorimetric tube; add
0.5 ml of tartaric acid solution (100 g/l) and 1 drop of phenolphthalein indicator solution (10.0 g/l) into each
and mix it well; add ammonia solution (1 + 1) into each till it becomes pink; add 3.0 ml of sulfuric acid
solution (1 + 9), 1.0 ml of animal gelatin solution (5.0 g/l) and 2.5 ml of ascorbic acid solution (10.0 g/l); add
water then till the volume reaches 25 ml and mix it well; then add 2.0 ml of phenylfuoron solution, mix it well
and allow it to stand for 1h; and measure then.
Use 2 cm cuvette to measure absorbance at 490 nm of wavelength; after zero tube absorbance is
subtracted from all standard points, take concentration of the standard series solution as the horizontal axis
and absorbance as vertical axis to map the standard curve or calculate the linear regression equation.
Use 2 cm cuvette to adjust zero point per standard series solution zero tube; measure absorbance of
reagent blank solution and specimen solution respectively at 490 nm of wavelength; compare the resulting
absorbance to standard curve or substitute it into regression equation to calculate the content.
X- tin content in the specimen, in milligram per kilogram or milligram per liter (mg/kg or mg/l);
m1- tin mass in specimen digestion solution for purpose of determination, in microgram (μg);
V2- volume of specimen digestion solution for purpose of determination, in milliliter (ml).
14. Precision
Absolute difference between two independent determination results obtained under the repeatability
conditions shall not exceed 10% of their arithmetic mean.
15. Others
When 1.0g of such specimen and 5.0 ml of digestion solution are taken for determination, the quantitative
limit of this method shall be 20 mg/kg.
GB 5009.190-2014
Compared with GB/T 5009.190—2006, this standard has the following main changes:
1. Scope
Method I of this standard specifies the way to measure the content of PCBs (polychlorinated biphenyls) in
food, including the indicative PCBs specified in the Global Environmental Monitoring System (GEMS)/food
programme (PCB28, PCB52, PCB101, PCB118, PCB138, PCB153 and PCB180), as well as PCB18,
PCB33, PCB44, PCB70, PCB105, PCB128, PCB170, PCB187, PCB194, PCB195 and PCB199. Method II
specifies the way to measure the content of PCB28, PCB52, PCB101, PCB118, PCB138, PCB153 and
PCB180.
This standard is applicable to the measurement of indicative PCBs in samples of animal-derived food and oil
or fat including fish, shellfish, eggs, meat, dairy and their products.
2. Principles
The stable isotope dilution technique is applied in the standard to add 13C12-marked PCBs into the samples
as the quantitative criterion. Sample solutions going through Soxhlet extraction shall be added to the internal
standard of recovery after the chromatographic purification of column chromatography, separation and
concentration. Then an analysis shall be made with gas chromatography-low resolution mass spectrometer,
quadrupole mass selective ion monitoring (SIM)or ion trap tandem mass spectrometry multiple- reaction
monitoring (MRM) and determination with the internal standard method shall be carried out.
3.1 Reagents
3.1.6. Anhydrous Na2SO4: Top grade pure. We shall put the commercially available anhydrous Na2SO4
into the chromatographic column and rinse it twice with normal hexane and dichloromethane. The volume of
solvent used every time shall be approximately twice that of anhydrous Na2SO4. After the rinse, we shall
transfer the anhydrous Na2SO4 into the flask where it dries at 50 ℃before baking it at 225°C for 8 to 12
hours and storing it in the dryer.
3.1.10. Silica gel for chromatography (75μm~250μm): We shall put the commercially available anhydrous
Na2SO4 into the chromatographic column and rinse it twice with normal hexane and dichloromethane. The
volume of solvent used every time shall be approximately twice that of silica gel. After the rinse, we shall
transfer the silica gel into the flask which will be capped and placed in the oven to dry up at 50 ℃
. Then we
shall bake it at 180°C for 8 to 12 hours and place it in the reagent bottle with ground stopper after cooling,
which will be stored in the dryer.
3.1.11. 44% acidated silica gel: Weigh 100 g of activated silica gel and drip 78.6 g of sulfuric acid in. Then
shake it until lumps disappear before placing it into the reagent bottle with ground stopper, which will be
stored in the dryer.
3.1.12. 33% alkaline silica gel: Weigh 100 g of activated silica gel and drip 49.2 g of 1 mol/L sodium
hydroxide solution in. Then shake it until lumps disappear before placing it into the reagent bottle with
ground stopper, which will be stored in the dryer.
3.1.13. 10% silver nitrate impregnated silica gel: Dissolve 5.6 g of silver nitrate in 21.5 mL of deionized
water and drip it into 50 g of activated silica gel. Then shake it until lumps disappear before placing it into the
reagent bottle with ground stopper, which will be stored in the dryer.
3.1.14. Alkaline aluminium oxide for chromatographic analysis: to bake it at 660 ℃for 6 hours and place it
into the reagent bottle with ground stopper, which will be stored in the dryer.
3.2.1. Standard solutions for time window determination: comprising homologues when different PCBs
appear at the first and last peaks on the DB-5ms chromatographic column. Please see A.1 at Appendix A.
3.2.2. Internal standard solutions for quantification: Please see A.2 at Appendix A.
3.2.3. Internal standard solutions for recovery: Please see A.3 at Appendix A.
3.2.5. Standard solutions for accuracy and preciseness: Please see A.5 at Appendix A.
4.1 Gas chromatography-quadrupole mass spectrometer (GC-MS) or gas chromatography-ion trap tandem
mass spectrometer (GC-MS/MS).
4.2 Chromatographic column: DB-5ms column,30 m×0.25 mm×0.25 μm, or equivalent chromatographic
column
4.8 Oscillator
4.10 Preparation for glassware instruments: all re-usable glassware shall be thoroughly rinsed after use
in the following procedure.
The combination of supersonic cleaners and warm water that contains alkaline detergents produces very
good cleaning effects. Be careful not to damage the internal surface of the glassware instrument when
cleansing it with a brush.
5. Analytical procedures
5.1.1. Pre-treatment
5.1.1.1 Samples collected on site shall be packaged with light-proof materials such as aluminum foil and
brown glass bottles before being delivered to the lab in a small-sized refrigerator, where they are kept at -10℃
or lower.
5.1.1.2 Solid samples such as fish and meat can be freeze-dried or dried with anhydrous Na2SO4 and
evenly mixed. Oil or fat can directly dissolve in the normal hexane for purification.
5.1.2. Extraction
5.1.2.1 Before extraction, we shall put an empty cellulose or fiberglass socket into the Soxhlet extractor and
pre-extract it for 8 hours with normal hexane + dichloromethane (50+50) as the extraction solvent before
drying.
5.1.2.2 We shall put 5.0 to 10.0 g of pre-treated samples into the above-mentioned extraction socket in
5.1.2.1 and add 13C12-marked quantitative interior standard (3.2.2). Then we shall cover the samples with
glass wool which will be put into the Soxhlet extractor after a 30-minute balance. We shall extract it for 18 to
24 hours with normal hexane + dichloromethane (50+50) as the extraction solvent while keeping the
back-flow velocity at 3 to 4 times per hour
5.1.2.3 After the extraction, we shall transfer the extracting solution into the eggplant-shaped bottle while
evaporating it in a rotatory way until it is almost dry. Where the analysis result must be calculated in terms of
fat, fat content is needed to test the samples.
Copyright @ 2015 The Sovereign Group All Rights Reserved
112
5.1.2.4 Determination of fat content: We shall determine the exact weight of the eggplant-shaped bottle
before concentration and dry the solvent before weighing the bottle. The difference value of the two results
shall be the fat content of samples. After the determination, we shall add a small amount of normal hexane
to dissolve the residue in the bottle.
5.1.3. Purification
Decontaminating column filling: We shall fill in 4 g of activated silica gel, 10 g of acid silica gel, 2 g of
activated silica gel and 4 g of anhydrous Na2SO4 in sequence from bottom to top after blocking the glass
column end with glass wool (see the Fig D.1 in Appendix D). Then we shall pre-wash it with 100 ml of normal
hexane.
Purification: We shall transfer all the condensed extracting solution to the column and rinse the
eggplant-shaped bottle with about 5 mL of normal hexane for 3 or 4 times before transferring the washer
liquid to the column.
When the liquid level lowers to the anhydrous Na2SO4 layer, we shall add 180 mL of normal hexane for
elution and condense the eluent to about 1 mL. When the acidated silica gel layers are all discolored, it
means that the fat content in the samples has gone beyond the column load limit. After the condensation of
eluent, we shall produce a new acid silica gel purification column and repeat the above procedures until the
sulfuric acid silica gel doesn’t get discolored.
Decontaminating column filling: We shall fill in 1.5 g of silver nitrate impregnated silica gel, 1 g of activated
silica gel, 2 g of alkaline silica gel, 1 g of activated silica gel, 4 g of acidated silica gel, 2 g of activated silica
gel and 2 g of anhydrous Na2SO4 in sequence from bottom to top after blocking the glass column end with
glass wool (see the Fig D.1 in Appendix D). Then we shall pre-wash it with 30 mL of normal hexane and
dichloromethane (97+3).
Purification: We shall transfer all condensed eluent that is purified in 5.1.3.1 to the column and rinse the
eggplant-shaped bottle with about 5 mL of normal hexane for 3 or 4 times before transferring the washer
liquid to the column. When the liquid level lowers to the anhydrous Na2SO4 layer, we shall add 50 ml of
normal hexane and dichloromethane (97+3) for elution and condense the eluent to about 1 mL.
Decontaminating column filling: We shall fill in 2.5 g of baked alkaline aluminum oxide and 2 g of anhydrous
Na2SO4 in sequence from bottom to top after blocking the glass column end with glass wool (see the Fig D.1
in Appendix D). Then we shall pre-wash it with 15 mL of normal hexane.
Purification: We shall transfer all condensed eluent that is purified in 5.1.3.2 to the column and rinse the
eggplant-shaped bottle with about 5 mL of normal hexane for 3 or 4 times before transferring the washer
liquid to the column. When the liquid level lowers to the anhydrous Na2SO4 layer, we shall add 30 mL of
normal hexane (2×15 mL)for elution. Then when the liquid level lowers to the anhydrous Na2SO4 layer, we
shall add 25 mL of dichloromethane and normal hexane(5+95), and condense the eluent until it’s nearly dry.
We shall transfer the purified sample solution into the sample introduction pipe and condense the nitrogen
Copyright @ 2015 The Sovereign Group All Rights Reserved
113
when it flows down. Then we shall rinse the eggplant-shaped bottle with a small amount of normal hexane
for three to four times and transfer the washing liquid into the sample introduction insert-pipe before
condensing the nitrogen to about 50 μl. Then we shall add an appropriate amount of internal standard of
recovery (3.2.3) and cap it before analysis on the equipment.
5.2.1.1 Chromatographic column: To carry out chromatographic separation with the 30-m DB-5ms (or other
type which is equal to DB-5ms) quartz capillary column. The film thickness shall be 0.25 μm and the inner
diameter 0.25 mm.
5.2.1.2 The temperature at the injection port shall be 300 ℃when using splitless injection.
5.2.1.3 The temperature of the chromatographic column rises in the following way: the initial temperature
stays at 100 ℃for 2 min; then to 180℃at 15℃ /min. Finally to 285 ℃at 10 ℃
/min; then to 240℃at 3℃ /min and stay
for 10 minutes.
Ionization mode: Electron Impact Ion Source (EI); 70 eV. Ion detection mode: selected ion monitoring
(SIM); The characteristic ion that is selected when detecting the PCBs is a molecular ion. See Table B.1 at
Appendix B.
Ionization mode: Electron Impact Ion Source;70 eV. Ion detection mode: multiple- reaction
monitoring(MRM);The parent ion that is selected when detecting the PCBs is a molecular ion (M+2 or M+4)
and the daughter ion is a fragment ion(M-2Cl)that is formed when a molecular ion loses two helium atoms.
See the Table B.2 at Appendix B. The ion trap temperature shall be 220℃
; the transmission line temperature
shall be 280℃; the manifold temperature shall be 40 ℃.
To inject 1 μL(20 pg)of CS1 solution and detect the GC-MS sensitivity. Detection ion SNR (Signal to Noise
Ratio) of all 3-to-7-cl-substitution compounds shall be up to above 3, or the equipment shall be tuned again
until it meets the requirement.
5.4.1 Confirmation requirement for PCBs’ chromatographic peak: The SNR of detected chromatographic
peak shall be above 3 (See Fig C.1 or C.3 at Appendix C)
5.4.2 The abundance ratio of the two detected characteristic ion shall be within the theoretical range.
Please see Table B.1 and B.2 at Appendix B.
5.4.3 To detect mass spectrum corresponding with the chromatographic peak (See Fig C.2 or C.4 at
Appendix C). When the concentration is high enough, there shall be a fragment ion which loses two helium
atoms (M-70). See Fig B.1 at Appendix B.
5.4.4 To detect the mass spectrum this corresponds with the chromatographic peak (See Fig C.2 or C.4
at Appendix C). There shall not be any fragment ion with molecular ions and two helium atoms (M+70)See
Fig B.1 at Appendix B.
5.4.5 The retention time of determined PCBs shall be located at the time window which determines the
standard solution via the analysis window. Time window determination standard solution comprises
homologues when different PCBs appear at the first and last peaks on the DB-5ms chromatographic column.
The time window shall be determined according to the retention period where different PCBs are by making
analysis on window determination solution (1 μL) with the determined chromatographic condition and
full-scan mass spectrum acquisition mode. Due to the overlap of retention periods of PCBs from three
families in the DB-5ms chromatographic column, characteristic ions of these PCBs shall be detected in a
single time window. To ensure the selectivity and sensitivity of the analysis, the detected characteristic ions
at one window when determining the time window shall be as little as possible.
5.5.1 During the standard, PCB28, PCB52, PCB118, PCB153, PCB180, PCB206 and PCB209 are
quantified with the isotope dilution technique. Other target compounds shall be quantified with the internal
standard method and the recovery calculation of internal standard for quantification shall be done with the
internal standard method. The 20 target compounds determined in the standard include most PCBs’
industrial products. There are 3 compounds in every family from PCB3 to PCB8. There is one in PCB9 or
PCB10. See the Table A.4 in Appendix A. One 13C12-marked compound is used as internal standard for
quantification in every family. See the Table A.2 in Appendix A. There are two internal standards of recovery
to calculate the quantified internal standard recovery. See the Table A.3 in Appendix A.When calculating the
quantified internal standard recovery, 13C12-PCB101 shall be used as the internal standards of recovery for
13
C12-PCB28, 13C12-PCB52, 13C12-1PCB18 and 113C12-PCB153 and 13C12-PCB194 shall be used as the
internal standards of recovery for 13C12-PCB180, 13C12-PCB202, 13C12-PCB206 and 13C12-PCB209.
5.5.2 Relative Response Factor (RRF):In this standard, RRF is used for quantitative calculation. The
RRF value is calculated with calibration standard solution. See the computational formulas at (1) and (2).
RRFn— the relative response factor of target compounds to internal standard for quantification;
RRFr—the relative response factor of internal standard for quantification to internal standard for recovery;
The RRF values of the five thickness levels for different compounds shall have the relative standard
deviation (RSD) of less than 20%. When the standard is met, we shall use average RRFn and average RRFr
for quantitative calculation.
5.5.3 Content calculation: see (3) for calculation formula of PCBs content in samples
In the formula,
RRFn—the relative response factor of target compounds to internal standard for quantification;
m—sampling weight(g)
5.5.4 Calculation of quantified internal standard of recovery: quantified internal standard of recovery(R) is
calculated according to (4) and the quantitative value is symbolized with %.
RRFr—the relative response factor of quantified internal standard to internal standard for recovery;
Quantitative Results can have two digits after the decimal point.
5.5.5 Limit of detection: it is specified by this standard that the sample detection limit constitutes the
sample solution concentration which corresponds with the response that meets the requirement of isotope
abundance ratio when the SNR (Signal to Noise Ratio) is 3. See (5) for the computational formula of
detection limit.
In the formula:
RRFn—the relative response factor of target compounds to internal standard for quantification;
m—sample volume,(g).
The sample base material, sampling volume, injected sample size, quantified internal standard of recovery,
chromatographic separation, electrical noises and equipment sensitivity all may affect the sample detection
limit, so the noise shall be acquired from the real sample spectrogram. The sample detection limit shall be
reported when the outcome of target compounds hasn’t come out yet.
The lab shall have the acceptable accuracy and preciseness before analyzing the real samples. Reliability of
the analytical methods shall be verified by analyzing marked samples.
We shall use 3 or more blank samples whose base materials are similar to the real samples, in which we
respectively add normal experiment solution with the right accuracy and preciseness. See Table A.5 for
Appendix A. Then we shall respectively add standard solution of internal standard for quantification before
analyzing the formulated marked samples in the same way as the real samples, and calculate the recovery
of target compounds and the quantified internal standard of recovery. The estimated value of target PCBs for
every sample shall range from 75% to 120% of the addition quantity. RSD<30%. The average of recovery
for quantified internal standard shall range from 50% to 120%. And the quantified internal standard of
recovery for single samples shall range from 30% to 130%.
Before being analyzed, real samples shall meet the above requirements. When the way to extract and purify
the samples has been modified or the analyzer has been replaced, such experiments shall be repeated until
the above requirements are met. The above experiments shall be done in the lab every 6 months to ensure
that the above requirements are met.
If we can have standard reference materials which have base materials similar to samples, then we can
apply normal reference materials to the accuracy and preciseness experiment instead of marked samples.
Quantified internal standard shall be added to rectify the loss of target compounds during the extraction and
purification of the samples. Quantified internal standard of recovery shall range from 30% to 130%. If the
sample analysis outcome for quantified internal standard of recovery hasn’t met the above requirement,
samples shall be extracted, purified and analyzed on the equipment again.
A method blank experiment shall be done on every group which has at most 15 samples.
There are at most 15 samples for every group with a quality control sample. Quality control samples shall be
standard reference material or marked sample with known concentration. The estimated value of target
compounds shall range from 75% to 125% of the standard values.
Time window shall be carried out every week to determine the analysis of standard solution and the
correctness of retention time window. When the chromatographic column has been replaced or cut, or the
chromatographic parameter has been changed, time window shall be used to determine the standard
solution and calibrate the retention time window.
Calibration standard solutions with 5 thickness levels shall be used for initial calibration. Calibration is
regarded to be successful when the RSD of RRF is less than 20%. During the analysis, confirmatory tests
Copyright @ 2015 The Sovereign Group All Rights Reserved
118
shall be done every 12 hours. CS3 in the calibration standard solutions shall be used for equipment analysis.
The analysis outcome shall be within the scope of 20% of its constant value. Quantified internal standard of
recovery shall be within
75% to 125%.
7. Others
8. Principle
With this method, we add PCB198, the quantified internal standard, into the samples and heat it in the water
bath before vibrating extraction. After the sulfuric acid treatment and purification of chromatographic column,
we shall make the measurement with the gas chromatographic- electron capture detector method so as to
ensure the time qualification and internal standard quantification.
9.1 Reagent
9.1.4 Anhydrous Na2SO4: Top grade pure. We shall put the commercially available anhydrous Na2SO4
into the glass chromatographic column and rinse it twice with normal hexane and dichloromethane. The
volume of solvent used every time shall be approximately twice that of anhydrous Na2SO4 . After the rinse,
we shall transfer the anhydrous Na2SO4 into the flask where it dries at 50 ℃before baking it at 225°C
overnight and storing it in the dryer when it cools down.
9.1.6 Alkaline aluminium oxide for chromatographic analysis: to bake the commercially available
chromatographic packing materials at 660 ℃for 6 hours and place it into the dryer for storage.
10.1.2 Chromatographic column: DB-5ms column,30 m×0.25 mm×0.25 μm,or equivalent chromatographic
column
Copyright @ 2015 The Sovereign Group All Rights Reserved
119
10.1.3 Tissue homogenizer
10.1.11 Centrifuge
11.1.1 Solid sample:Weigh 5 g to 10 g of samples ( accurate to 0.1 g) and place it into the conical flask
with cover. Then add some quantified PCB198 and place it on the water bath oscillator for 2 hours with an
appropriate amount of normal hexane + dichloromethane (50+50) as the extract solution. The water bath
temperature shall be at 40 ℃and the vibrating rate shall be at 200 r/min.
11.1.2 Liquid sample (exclusive of oil and fat sample): Weigh 10 of samples (accurate to 0.1 g) and place it
into the conical flask with cover. Then add quantified internal standard PCB198 and 0.5 g of sodium oxalate
to be evenly mixed with 10 mL of methyl alcohol. Next, add 20 mL of aether and n-hexane (25+75) to be
oscillated for 20 minutes and centrifuged at 3,000 r/ min for 5 minutes. Then transfer the supernatant liquor
to the glass column which has 5 g of anhydrous Na2SO4. Add 20 mL of aether and n-hexane (25+75) in the
residue and repeat the above procedure. Finally combine the extracting solution.
11.1.3 Transfer the extracting solution to the eggplant-shaped bottle and rotate to evaporate it until it is
nearly dry. Fat content of the sample shall be determined if the analysis result is calculated by fat.
11.1.4 Determination of the sample fat: Get the exact weight of the empty eggplant-shaped bottle before
concentration. Then dry the solvent and weigh the bottle and the residue again. The difference value of the
two results shall be the fat content of samples.
11.2 Purification
Transfer the condensed extracting solution into the 10-mL test tube and rinse the eggplant-shaped bottle
for 3 to 4 times with approximately 5 mL of normal hexane before combining it with the concentrated solution.
Meter the volume to the scale with normal hexane and add 0.5 mL of concentrated sulfuric acid. Then shake
it for 1 minute and centrifuge it at 3,000 r/min, thus separating the sulfuric acid layer from the organic layer.
If the upper solution is still colored, that means the fat still remains. So add an appropriate amount of
Decontaminating column filling: We shall add a small amount of glass wool at the glass column end and fill in
2.5 g of baked alkaline aluminium oxide and 2 g of anhydrous Na2SO4 in sequence before rinsing it with 15
mL of normal hexane.
Purification: We shall transfer concentrated solution at 11.2.1 and rinse the eggplant-shaped bottle for 3 to 4
times with 5 mL of normal hexane before transferring it to the chromatographic column. When the liquid level
lowers to the anhydrous Na2SO4 layer, we shall add 30 mL of normal hexane (2×15 mL) for elution. Then
when the liquid level lowers to the anhydrous Na2SO4 layer,we shall add 25 mL of dichloromethane and
normal hexane(5+95) for elution, and condense the eluent until it’s nearly dry.
Transfer the sample solution in 11.2.2 to the sample introduction bottle and rinse the eggplant-shaped bottle
with a small amount of normal hexane for 3 to 4 times. Then add the cleansing solution into the sample
introduction bottle. Finally condense it to 1 mL under the nitrogen flow for GC analysis.
12. Determination
12.1.1 Chromatographic column: DB-5ms column,30 m×0.25 mm×0.25 μm,or equivalent chromatographic
column
12.1.3 Temperature raising procedure: starting temperature at 90 ℃ , remaining for 0.5 minutes; to 200 ℃
at 15 ℃
/min for 5 minutes; to 250°C at 2.5 ℃
/min for 2 minutes; then to 265°C at 20℃ /min for 5 minutes
12.1.6 Chromatographic analysis: to keep the qualitative time and compare the quantity with the peak
height or peak area of samples and standard.
To make qualitative analysis with retention time or relative retention time. SNR(Signal to Noise Ratio) for the
chromatographic peak of the detected PCBs shall be more than 3.
To make quantitative calculation with RRF by using the internal standard method. To calculate RRF value
according to (6)by using the calibrating standard solution sample introduction:
In the standard solutions, RSD (relative standard deviation) of the RRF value of all target compounds shall
be less than 20%.
In the formula,
m—sampling weight(g).
It is specified by this standard that the sample detection limit constitutes the sample solution concentration
which corresponds with the response that meets the requirement of relative retention time with triple
SNR.See the computational formula at (8):
In the formula:
Copyright @ 2015 The Sovereign Group All Rights Reserved
122
DL—limit of detection (μg/kg)
RRF—the relative response factor of target compounds to internal standard for quantification;
m—sample volume,(g).
The sample base material, sampling volume, injected sample size, chromatographic separation, electrical
noises and equipment sensitivity all may affect the sample detection limit, so the noise shall be acquired
from the real sample spectrogram. The sample detection limit shall be reported when the outcome of target
compounds hasn’t come out yet.
13. Accuracy
Absolute differences of the two individual analysis results acquired under repetitive conditions shall be 20%
of the arithmetic mean value or less.
14. Others
Table A.1 Standard solution to determine the time window of indicative PCBs tested with the GC-MS
method
Concentration
Compounds Chlorine atom amount
mg/L
Biphenyl 0 2.5±0.25
PCB1 1 2.5±0.25
PCB3 1 2.5±0.25
PCB10 2 2.5±0.25
PCB15 2 2.5±0.25
PCB30 3 2.5±0.25
PCB37 3 2.5±0.25
PCB54 4 2.5±0.25
PCB77 4 2.5±0.25
PCB104 5 2.5±0.25
PCB126 5 2.5±0.25
PCB155 6 2.5±0.25
PCB169 6 2.5±0.25
PCB188 7 2.5±0.25
PCB189 7 2.5±0.25
PCB194 8 2.5±0.25
PCB202 8 2.5±0.25
PCB206 9 2.5±0.25
PCB208 9 2.5±0.25
PCB209 10 2.5±0.25
Concentration
Compounds Chlorine atom amount
mg/L
13C12-PCB28 3 2.0
13C12-PCB52 4 2.0
13C12-PCB118 5 2.0
13C12-PCB153 6 2.0
13C12-PCB180 7 2.0
13C12-PCB202 8 2.0
13C12-PCB206 9 2.0
13C12-PCB209 10 2.0
Table A.3 Standard solution for the internal standard of recovery of indicative PCBs in the GC-MS method
Concentration
Compounds Chlorine atom amount
mg/L
13C12-PCB101 5 2.0
13C12-PCB194 8 2.0
Concentration
μg/L
Target compounds
CS1 CS2 CS3 CS4 CS5
PCB18 20 50 200 800 2000
PCB28 20 50 200 800 2000
PCB33 20 50 200 800 2000
PCB52 20 50 200 800 2000
PCB44 20 50 200 800 2000
PCB70 20 50 200 800 2000
PCB101 20 50 200 800 2000
PCB118 20 50 200 800 2000
PCB105 20 50 200 800 2000
PCB153 20 50 200 800 2000
Natural compounds
PCB138 20 50 200 800 2000
PCB128 20 50 200 800 2000
PCB187 20 50 200 800 2000
PCB180 20 50 200 800 2000
PCB170 20 50 200 800 2000
PCB199 20 50 200 800 2000
PCB195 20 50 200 800 2000
PCB194 20 50 200 800 2000
PCB206 20 50 200 800 2000
PCB209 20 50 200 800 2000
13C12-PCB180 400 400 400 400 400
13C12-PCB202 400 400 400 400 400
13C12-PCB206 400 400 400 400 400
Quantified internal 13C12-PCB209 400 400 400 400 400
standard of isotope
13C12-PCB28 400 400 400 400 400
labeling
13C12-PCB52 400 400 400 400 400
13C12-PCB118 400 400 400 400 400
13C12-PCB153 400 400 400 400 400
Internal standard for 13C12-PCB101 400 400 400 400 400
recovery of isotope 13C12-PCB194 400 400 400 400 400
labeling
Concentration Concentration
Compounds Compounds
μg/L μg/L
Table A.6 Standard solution for indicative PCBs in the GC-ECD method
Concentration
Compounds μg/L
CS1 CS2 CS3 CS4 CS5
PCB28 5 20 50 200 800
PCB52 5 20 50 200 800
PCB101 5 20 50 200 800
PCB118 5 20 50 200 800
PCB138 5 20 50 200 800
PCB153 5 20 50 200 800
PCB180 5 20 50 200 800
PCB198(Quantified
50 50 50 50 50
internal standard)
Table B.1 Characteristic ions and isotopic abundance ratio of selected ion monitoring (SIM) of the
quadrupole mass spectrometer
13
C12-P5CB 338 266/268 0.67
13
C12-H6CB 372 300/302 0.50
13
C12-H7CB 408 336/338 1.00
13
C12-O8CB 442 370/372 0.80
13
C12-N9CB 476 404/406 0.67
13
C12-D10CB 510 438/440 0.55
Fig C.1 and C.2 are the SIM chromatogram and mass spectrum to determine PCBs with the quadrupole mass
spectrometer. Fig C.3 and C.4 are the MRM chromatogram and mass spectrum to determine the PCBs with the
ion trap mass spectrometer.
Fig C.1 Mass chromatogram of characteristic ions of target PCBs with SIM
PCB4
PCB5
PCB6
Fig C.2 Mass spectrum of characteristic ions of different PCBs with SIM
PCB8
PCB9
PCB10
PCB4
PCB5
Fig C.4 Mass spectrum of different target PCBs daughter ions with MRM
PCB7
PCB8
PCB10
Anhydrous
sodium
sulfate Anhydrous sodium
Anhydrous
sodium sulfate sulfate
2 g of activated 2 g of activated silica
silica gel gel
Glass wool
Glass wool
Alumina column Compound silica gel column Acidized silica gel column
Alumina column
1) 30 mL of n-hexane
2) 25 mL of n-hexane dichloromethane
To remove the
grease with sulfuric
Alumina column
1) 30 mL of n-hexane
2) n-hexane:dichloromethane (95:5)
Fig D.3 Flow chart to determine the PCBs in food with the gas chromatography-electron capture
detector
GB 5009.204-2014
Compared with GB/T 5009.204—2005, this standard has the following main changes:
- Method I, Mass-spectrography, gas chromatography to dilute stable isotopes, has been added.
- The GC-MS method has changed the external standard method into stable isotopes dilution method.
1. Scope
The standard is applicable to the determination of acrylamide in heat processed (fried, baked, roasted,
grilled, etc) foods.
2. Principles
The stable isotope dilution technique is applied in the standard to add 13C12-marked PCBs into the samples
with water as the extraction solvent. After the solid phase extraction or base material solid phase extraction
purification, detection shall be made with the multiple reactions monitoring (MRM) of Liquid
chromatography-mass spectrography/ mass-spectrography or selective reaction monitoring (SRM) and
determination with the internal standard method shall be carried out.
Notes: Unless otherwise stated, all reagents in the method shall be analytically pure and the water shall be
Grade I water specified in GB/T 6682.
3.1 Reagents
3.1.3 Normal hexane (n-C6H14): analytically pure, used after being re-distilled.
3.1.4 Ethyl acetate (CH3COOC2H5): analytically pure, used after being re-distilled.
3.3.1.2 Acrylamide midst solution(100 mg/L): Transfer 1 mL of acrylamide standard stock solution and
dilute it to 10 mL with methanol to make the acrylamide concentration reach 100 mg/L before storing it in
the refrigerator at ﹣20 ℃
.
3.3.1.3 Acrylamide work solution I (10 mg/L): Transfer 1 mL of acrylamide midst solution and dilute it to
10 mL with 0.1% methanoic acid solution to make the acrylamide concentration reach 10 mg/L. It shall be
formulated when being used.
3.3.1.4 Acrylamide work solution II (1 mg/L): Transfer 1 mL of acrylamide work solution I and dilute it to
10 mL with 0.1% methanoic acid solution to make the acrylamide concentration reach 1mg/L. It shall be
formulated when being used.
13
3.3.2 C 3-acrylamide internal standard solution
13
3.3.2.1 C3-acrylamide internal standard stock solution(1,000 mg/L):accurately weigh 13C3-acrylamide
standard product and dissolve it with methanol to make the 13C3-acrylamide concentration reach 1,000
mg/L before storing it in the refrigerator at ﹣20 ℃
.
3.3.2.2 Internal standard work solution(10 mg/L):Transfer 1 mL of internal standard stock solution and
dissolve it to 100 mL with methanoic acid to make the 13C3-acrylamide concentration reach 10 mg/L before
storing it in the refrigerator at ﹣20 ℃
.
Take 6 10-mL volumetric flasks to separately transfer 0.1 mL, 0.5 mL and 1 mL of acrylamide work solution
II (1 mg/L), 1 mL and 3 mL of acrylamide work solution I (10 mg/L) and 0.1 mL of internal standard work
solution (10 mg/L). Then dilute it with 0.1% methanoic acid solution to the scale. Acrylamide concentration
in the standard solution shall be separately 10 μg/L, 50 μg/L, 100 μg/L, 500 μg/L, 1,000 μg/L and 3,000
μg/L. The internal standard concentration shall be 100 μg/L. It shall be formulated when being used.
4.2 HLB solid phase extraction column:6 mL, 200 mg, or equivalent products
4.3 Bond Elut-Accucat solid phase extraction column:3 mL, 200 mg,or equivalent products
4.8 Glass chromatographic column: column length--30 cm, column internal diameter --1.8 cm
5. Analytical procedure
Take 50 g of samples and grind them with the grinder and then store the at ﹣20℃
. Accurately weigh 1 g to 2 g of
samples (correct to 0.001 g). 10 μL or 20 μL of 13C3-acrylamide internal standard (10 mg/L) shall be added,
which is equal to 100 ng or 200 ng of 13C3-acrylamide internal standard. Then add 10 mL of ultra-pure water
and shake it for 30 minutes to centrifuge it at 4,000 r/m for 10 minutes. Finally acquire the liquid supernatant for
purification.
5.1.2.1 Base material solid-phase dispersion extraction method (Selection 1):add 15 g of ammonium
sulfate into the liquid supernatant extracted from the samples and shake for 10 minutes to fully dissolve it
before centrifuging it at 4,000 r/m for 10 minutes. Get 10 mL of liquid supernatant for use. When the liquid
supernatant doesn’t reach 10 mL, saturated ammonium sulfate shall be used for complement. Put a little
glass wool in the bottom of a pure glass chromatography column and press it tightly. Then fill in 10 g of
anhydrous Na2SO4 and 2g of diatomite in sequence. Mix 5 g of diatomite ExtrelutTM 20 with the liquid
supernatant of the above samples and then fill it in the chromatographic column. Rinse it with 70 mL of
normal hexane at 2 mL/min and then remove the normal hexane. Elute the acrylamide with 70mL of ethyl
acetate at 2 mL/min. Then collect the ethyl acetate elution solution and place it under the vacuum-rotary
evaporation procedure at the 45 ℃water bath until it’s nearly dry. Rinse the residue in the evaporating flask
with ethyl acetate for three times (1 mL every time) and then transfer it into the test tube which already has
1 mL of 0.1% methanoic acid solution before vortex oscillation. Blow away the upper organic phase with
nitrogen and add in 1 mL of normal hexane before vortex oscillation. Then centrifuge it at 3,500 r/m for 5
minutes. Filter the upper organic phase with the 0.22 μm aqueous phase filter membrane for LC-MS/MS
test.
5.1.2.2 Solid phase extraction column(Selection 1I): Add 5 mL of normal hexane into the liquid
supernatant from the samples for a 10-minute oscillation extraction. Then centrifuge it at 10,000 r/m for 5
minutes. Remove the organic phase and extract it again with 5 mL of normal hexane. Then rapidly get 6
mL of aqueous phase and filter it with the 0.45-μm aqueous phase filter and carry out HLB solid phase
extraction column purification. Activate the HLB solid phase extraction column with 3 mL of methyl alcohol
and 3 mL of water. Apply 5 mL of the above filter liquor to the HLB solid phase extraction column and
Copyright @ 2015 The Sovereign Group All Rights Reserved
145
collect the effluent. Then eluate it with 4 mL of 80% methanol water fluid and collect all the eluate. Then
mix it with the effluent for Bond Elut-Accucat solid phase extraction column purification; Activate the Bond
Elut-Accucat solid phase extraction column with 3 mL of methyl alcohol and 3mL of water. Add all the
samples of eluate for the HLB solid phase extraction column purification and make it outflow under the
action of gravity. Then collect all the eluate and concentrate it under the nitrogen flow until it’s nearly dry.
Finally dilute the 0.1% methanoic acid solution to 1.0 mL for LC-MS/MS determination.
The chromatographic column shall be Atlantis C18 Column (5 μm, 2.1 mm I.D.×150 mm) or equivalent
columns.
Pre-column: C18 Guard Column (5 μm, 2.1 mm I.D.×30 mm) or equivalent columns.
Column temperature: 26 ℃
Ionization mode:ESI+
Cone voltage:40 V
Acrylamide:parent ion m/z 72, daughter ion m/z 55, daughter ion m/z 44
13
C3 acrylamide:parent ion m/z 75, daughter ion m/z 58, daughter ion m/z 45
Collision Energy: 40 V
Acrylamide: parent ion m/z 72, daughter ion m/z 55, daughter ion m/z 44
13C acrylamide: parent ion m/z 75, daughter ion m/z 58, daughter ion m/z 45
3
Infuse the standard work liquid into Liquid Chromatogram-Mass Spectrum/ Mass Spectrometry System to
detect the peak area of corresponding acrylamide and their internal standard. Standard curves shall be
mapped by taking the acrylamide sampling concentration of all standard work liquid(μg/L)as the abscissa
and the peak area of acrylamide(m/z 55)and 13C3 acrylamide internal standard (m/z 58) as the ordinate.
Infuse the sample solution into the Liquid Chromatogram-Mass Spectrum/ Mass Spectrometry System and
measure the peak area ratio of acrylamide(m/z 55)and 13C3 acrylamide internal standard (m/z 58).
Acrylamide sampling concentration (μg/L) in the to-be-tested liquid is acquired according to standard curves.
Parallel determination shall be done twice or more.
Infuse the samples and standard work liquid into the Liquid Chromatogram- Mass Spectrum/Mass
Spectrometer in sequence to record the total ion chromatogram and mass spectrum (see Fig A.1 to A.2 at
Appendix A), as well as the peak area of acrylamide and internal standard and keep the abundance
Table 1 The maximum permissible deviation of relevant ion abundance in qualitative tests
The acrylamide content in the samples shall be calculated according to the Formula (1)Internal Standard
Method:
In the formula:
A—acrylamide weight which is in accordance with the peak area ratio of acrylamide(m/z
55)chromatographic peak and 13C3 acrylamide internal standard (m/z 58) chromatographic peak in the
samples (ng)
f—conversion factors of internal standard adding quantity in the samples (f=1 when the internal standard is
10 μL or f=2 when the internal standard is 20 μL)
Calculation results shall be shown with the arithmetic mean value of two individually analysis results
acquired on a repetitive basis. The outcome shall be calculate to a three-effective-digit number (or to the
first decimal place)
7. Precision
The absolute difference of the two independent analysis results acquired on a repetitive basis shall not
exceed the 20% of the arithmetic mean value.
8. Others
9. Principles
The standard shall adopt the stable isotope dilution technique and add 13C3-marked acrylamide internal
standard solution into the samples. By taking water as the extraction solvent,the sample extracting
solution makes a detection with MRM or SIM after adopting base material solid-phase dispersion
extraction purification and bromide reagent derivation.Determination with the internal standard method
shall be used.
Notes: Unless otherwise stated, all reagents in the method shall be analytically pure and the water shall be
ultra-pure water.
10.1 Reagents
10.2.1 Saturated bromine water:Measure 100 mL of ultra-pure water and place them in the 200-mL brown
reagent bottle. Then add in 8 mL of bromine and keep it out of the sun at 4 ℃for 8 hours. The upper level is
saturated bromine solution.
10.2.2 Bromizating agent: Weigh 20.0 g of potassium bromide and add 50 mL of ultra-pure water to totally
dissolve it. Then add in 1.0 mL of hydrobromic acid and 16.0 mL of saturated bromine water. Shake it up and
dilute it to 100 mL with ultra-pure water. Keep it out of the sun at 4 ℃
.
10.2.3 Sodium thiosulfate solution (0.1 mol/L): Weigh 2.48 g of sodium thiosulfate and add in 50 mL of
ultra-pure water to totally dissolve it. The dilute it to 100 mL with ultra-pure water and keep it out of the sun at
Copyright @ 2015 The Sovereign Group All Rights Reserved
150
4℃
.
10.2.4 Saturated ammonium sulfate solution: Weigh 80 g of ammonium sulfate crystals and add in 100 mL
of ultra-pure water. Dissolve it with the ultrasound and place it at the room temperature.
10.4.1 Acrylamide and its internal solution: alike to 3.3.1 and 3.3.2.
10.4.2 Standard curve work solution: Take 5 10-mL volumetric flasks to separately transfer 0.1 mL, 0.5 mL
and 2 mL of acrylamide work solution Ⅱ (1 mg/L) and 0.5 mL and 1 mL of crylamide work solution Ⅰ (1 mg/L),
as well as 0.5 mL of internal standard work solution(1 mg/L), with 5 10-mL volumetric flasks. The acrylamide
concentration in the standard solution shall be 10 μg/L, 50 μg/L, 200 μg/L, 500 μg/L and 1,000 μg/L. The
internal concentration shall be 50 μg/L. It shall be formulated when being used.
11.2 Chromatographic column:DB-5ms column (30 m×0.25 mm×0.25 μm) or equivalent chromatographic
column
11.6 Oscillator
11.7 Glass chromatographic column: column length-30 cm, column internal diameter -1.8cm
12 Analytical procedures
Add 15 g of ammonium sulfate to the liquid supernatant extracted from the samples and shake it for 10
minutes to fully dissolve it. Centrifuge it at 4,000 r/m for 10 minutes. Collect 10 mL of liquid supernatant for
use. Complement the liquid supernatant with saturated ammonium sulfate when the liquid supernatant is
less than 10 mL. Fill a little glass wool in the bottom of a clean glass chromatographic column and press it
tight. Then fill in 10 g of anhydrous Na2SO4 and 2 g of ExtrelutTM 20 diatomite.Weigh 5g of ExtrelutTM 20
diatomite and evenly mix it with the above prepared liquid supernatant samples before filling it in the
chromatographic column. Rinse it with 70 mL of normal hexane and keep the flow velocity at 2 mL/min. Then
remove the normal hexane eluent. Elute it with 70 mL of ethyl acetate and keep the flow velocity at 2 mL/min.
Then collect the ethyl acetate elution and nearly dry it under decompression and rotary evaporation in the
45 ℃water bath. Rinse the residues in the evaporating flasks with ethyl acetate for three times (1 mL every
time). Transfer it to the test tube with 1 mL of ultra-pure water for vortex oscillation. Blow away the upper
organic phase in the nitrogen flow and add 1 mL of normal hexane for vortex oscillation. Then centrifuge it at
3,500 r/m for 5 minutes and collect the lower aqueous phase for derivation.
12.1.3 Derivation
Sample derivation: add 1 mL of bromizating agent into the sample extracting solution for vortex oscillation.
Place it at 4 ℃for at least 1 hour and add in approximately 100 μL of sodium thiosulfate solution (0.1 mol/L)
for vortex oscillation to remove the residual derivative agents. Add in 2 mL of ethyl acetate for vortex
oscillation for 1 minute. Centrifuge it at 4,000 r/m for 5 minutes. Transfer the upper organic phase to the test
tube which contains 0.1 g of anhydrous sodium sulfate. Then repeat the extraction with 2 mL of ethyl acetate
and combine the organic phase. Still it for at least half an hour and transfer it to the other test tube before
blowing it until it’s nearly dry.Then add in 0.5 mL of ethyl acetate to dissolve the residue and leave it for use
(Notes: the volume of ethyl acetate which is used to dissolve the residues shall be adjusted according to the
sensitivity of instruments. Usually, its dosage shall be 0.5 mL when tandem mass spectrometers are used
for detection and 0.1 mL when monopole mass spectrometers are used).
Derivation of standard solution: measure several units of 1.0 mL standard solution and synchronously carry
out the above sample derivation method.
Chromatographic column: DB-5ms column (30 m×0.25 mm I.D×0.25 μm) or equivalent chromatographic
column
Injection port temperature: remain at 120 ℃for 2 minutes and then rise to 240 ℃at 40 ℃
/min where it stays for
5 minutes.
Chromatographic column program temperature: remain at 65 ℃for 1 minute and then rise to 200 ℃at
15 ℃
/min and then rise to 240 ℃at 40 ℃
/min where it stays for 5 minutes.
Carrier gas: high-purity helium (purity>99.999%), Pre-column pressure-69 mPa, equal to 10 psi.
Copyright @ 2015 The Sovereign Group All Rights Reserved
152
Unsplit stream sampling: injection volume-1 μL
Infuse the derivative standard work liquid into Gas Chromatography-Mass Spectrometry System to detect
the peak area of corresponding acrylamide and their internal standard. Linearity curves shall be mapped by
taking the acrylamide sampling concentration of all standard work liquid(μg/L)as the abscissa and the peak
area of 13C3 acrylamide internal standard detected on the quantitative ion quality chromatogram as the
ordinate.
Infuse the derivative sample solution into the Gas Chromatography-Mass Spectrometry System and
measure the peak area ratio of acrylamide and 13C3 acrylamide internal standard. Acrylamide sampling
concentration (μg/L) in the to-be-tested liquid is acquired according to standard curves. Parallel
determination shall be done twice or more.
Infuse the samples and standard work liquid into the Gas Chromatography/Mass Spectrometer in sequence
to record the total ion chromatogram and mass spectrum (see Fig A.3 to A.4 at Appendix A), as well as the
peak area of acrylamide and internal standard and keep the abundance qualification of time and fragment
ions. The chromatographic peak SNR of detected acrylamide shall be more than 3. The retention time of
target compounds in detected samples shall be in accordance with that in the standard solution. The
abundance ratio of the relevant monitoring ions of the target compounds in tested samples shall be in
accordance with that in the standard solution. See the permissible deviation at Table 1.
The acrylamide content in the samples shall be calculated according to the Formula (1) Internal Standard
Method.
15 Precision
The absolute difference of the two independent analysis results acquired on a repetitive basis shall not
exceed the 20% of the arithmetic mean value.
16 Others
A.1 Fig A.1 and A.2 are mass chromatogram and mass spectrum that are detected with LC-MS/MS.
Notes: From up to down is Total Ion Chromatogram (TIC), Acrylamide Selected Ion Flow Diagram(72→55)and
13C3-acrylamide Internal Standard Selected Ion Flow Diagram(75→58).
Fig A.1 Mass chromatogram of acrylamide and isotope internal standard 13C -acrylamide in potato chips
Fig A.2 Mass spectrum of acrylamide and internal standard 13C -acrylamideA.2 Fig A.3 and A.4 are mass
chromatogram and mass spectrum that are detected with LC-MS/MS.
Fig A.3 GC-MS full scan mass spectrum of bromo-derivation in the standard solution
Notes: From up to down is Total Ion Chromatogram (TIC) and mass chromatogram of acrylamide derivative m/z 150
and 13C3-acrylamide derivative m/z 155.
GB 5009.223-2014
1. Scope
This standard specifies the determination of urethane content in beer, wine, rice wine, liquor and other
alcoholic as well as in soy sauce by gas chromatography - mass spectrometry.
This standard applies to determination of urethane content in beer, wine, rice wine, liquor and other alcoholic
as well as in soy sauce.
2. Principle
After the specimen is added with D5-urethane internal standard substance, it will be purified and eluted by
alkaline diatomite SPE column. The elution solution will be calibrated by gas chromatography - mass
spectrometry after it is being concentrated. Limit of qualification will be fixed by internal standard method.
Note: except otherwise specified, all reagents used in this method are analytical pure reagents and water
are Class III water specified in GB/T6682.
3.1 Reagents
3.1.7 Alkaline diatomite SPE column: packing of 4,000 mg, and column capacity of 12 ml.
3.2.2 5% ethyl acetate - ether solution: take 5 ml of ethyl acetate, dilute it with ether solution to 100 ml, and
mix it well.
3.3.1 Urethane standard product (C3H7O2N, CAS: 51-79-6): with a purity greater than 99.0%.
3.3.2 D5-urethane standard product (C3H2D5NO2, CAS: 73962-07-9): with a purity greater than 98.0%.
Copyright @ 2015 The Sovereign Group All Rights Reserved
158
3.4 Formulation of standard solution
3.4.1 D5-urethane stock solution (1.00 mg/ml); weigh and take 0.01g (accurate to 0.0001 g) of D5-urethane
standard product, dissolve it with methanol solution, dilute it to a constant volume of 10 ml, and keep it at 4℃
3.4.2 D5- urethane use solution (2.00 μg/ml): imbibe 0.10 ml of D5-urethane use solution (1.00 mg/ml),
dilute it with methanol to 50 ml, and store it at 4℃or below.
3.4.3 Urethane stock solution (1.00 mg/ml): weigh and take 0.05g (accurate to 0.0001g) of urethane
standard product, dissolve it with methanol and dilute it to constant volume of 50 ml, and store at 4℃or below.
Shelf life lasts 3 months.
3.4.4 Urethane intermediate solution (10.0 μg/ml): imbibe and take 1.00 ml of urethane stock solution (1.00
mg/ml), dilute it with methanol to a constant volume of 100 ml, and store at 4℃or below. The shelf life lasts 1
month.
3.4.5 Urethane intermediate solution (0.50 μg/ml): imbibe and take 5.00 ml of urethane intermediate
solution (10.0 μg/ml), and dilute it by methanol to a constant volume of 100 ml, which is to be prepared right
away when needed.
3.4.6 Standard curve working solution: imbibe and take 20.0 μl, 50.0 μl, 100.0 μl, 200.0 μl, and 400.0 μl of
urethane intermediate solution (0.50 μg /ml) as well as 40.0 μl and 100.0 μl of urethane intermediate solution
(10.0μg /ml) respectively; transfer them into seven 1 ml volumetric flasks; add 100 μl of D5-urethane use
solution with a concentration of 2.00 μg/ml respectively and dilute it by methanol to mark; standard curve
solutions with a concentration of 10.0 ng/ml, 25.0 ng/ml, 50.0 ng/ml, 100 ng/ml, 200 ng/ml , 400 ng/ml, and
l000 ng/ml result. It shall be prepared right away when needed.
4.1 Gas chromatography - mass spectrometer, equipped with electron bombardment source (EI)
5 Analytical procedures
Shake up the specimen; weigh and take 2 g (accurate to 0.001 g) of specimen (weigh and take 5min later
after beer is ultrasonically degassed); add 100.0 μl of D5-urethane use solution with a concentration of 2.00
μg/ml as well as 0.3 g of sodium chloride (there is no need to add sodium chloride in case of soy sauce);
dissolve it ultrasonically, mix it well and add specimen onto alkaline diatomite SPE column; let the specimen
seep into the SPE column slowly under the vacuum condition and let it stand for 10 min. After being
Copyright @ 2015 The Sovereign Group All Rights Reserved
159
sprinkled and washed by 10 ml of n-hexane, elute it by 10 ml of 5% ethyl acetate-ether solution at a flow rate
of approx. 1 ml/min. After being dehydrated by a glass funnel containing 2 g of anhydrous sodium sulfate,
the resulting elution solution will be loaded into a 10 ml graduated test tube; blow it slowly by nitrogen gas to
0.5 ml or so at room temperature, dilute it to a constant volume of 1.00 ml by methanol, thus getting assay
solution prepared, which might be used for GC / MS analysis.
- Column temperature: initial temperature of 50℃ , holding for 1min and rising to 180℃at a rate of 8℃
/min;
after program running finishes, run 5 min after the temperature reaches 220℃ ;
- Injection volume: 1 μl ~ 2 μl
- Urethane selected ion monitoring (m/z):44, 62, 74, 89, quantitative ion 62;
- D5-urethane selected ion monitoring (m/z) 64, 76, quantitative ion 64.
Determine the standard working solution and specimen as per the conditions applicable to the method;
constant volume may be reduced when specimen of low concentration is to be characterized. Allowable
tolerance between mass chromatographic peak retention time of the specimen and that of the reference
substance shall be less than ± 2.5%; allowable tolerance between the relative abundance and concentration
of qualitative ion pairs vs. that of the standard working solution shall not exceed that specified in Table 1.
Conduct gas chromatography - mass spectrometer determination over urethane standard working curve
solutions of 10.0 ng/ml, 25.0 ng/ml, 50.0 ng/ml, 100 ng/ml, 200 ng/ml, 400 ng/ml, and l000 ng/ml (containing
200 ng/ml), with urethane concentration being taken as the horizontal axis, and peak area ratio between
urethane and D5-urethane in the standard curve working solution as the vertical axis to map the standard
curve.
Determine the specimen solution against the standard curve working solution; calculate urethane content in
the specimen as per that in the determination solution of urethane. When the specimen has a low
concentration of urethane, it is advised to take the standard curve working solution of 10.0 ng/ml, 25.0 ng/ml,
50.0 ng/ml, 100 ng/ml, and 200 ng/ml map the standard curve.
In the formula:
The calculated results shall be represented by the arithmetic mean of two independent measurement results
obtained under repeatability conditions and three-digit valid number shall be retained.
As regards the relative deviation of two independent determination results obtained under repeatability
conditions, when the content is ≤ 50 μg/kg, it shall not exceed 15% of the arithmetic mean; when the content
is >50 μg/kg, it shall not 10% of the arithmetic mean.
8 Others
When 2 g of specimen is taken, the detection limit of urethane in this method shall be 2 μg/kg and the limit of
quantification be 5.0 μg/kg.
A.1 Total ion of urethane and D5- urethane is shown in Figure A.1.
Abundance Urethane
Abundance
GB 14881-2013
- Emphasizes food safety control requirements in the entire food production process, namely raw
material purchase, processing, product storage and transportation; it also lists major control
measures for biological, chemical and physical contaminations;
- Modifies sections related to production equipment; the standard sets requirements on layout,
materials and design of the production equipment from the perspective of preventing biological,
chemical and physical contaminations;
- Adds relevant requirements for the procurement, inspection and acceptance, transportation and
storage of raw materials;
- Adds Appendix A: Guide of Monitoring Procedure for Microorganism in the Food Production
Environment”.
1. Scope
This standard specifies basic requirements and management rules for locations, facilities and personnel of
material purchasing, processing, packaging, storage and transportation in the process of food production.
This standard is applicable to production of various kinds of food; if it's necessary to develop a special
hygienic regulation for a certain kind of food production, this standard shall be taken as a basis.
2.1 Contamination
Process of biological, chemical and physical contamination factors transferred in the process of food
production.
Adverse effect caused by creatures such as insect, bird or rodent including fly, cockroach, sparrow and rat.
Operation personnel directly contacting packaged or unpackaged food, food equipment and instrument and
food contact surface.
2.5 Separation
Articles, facilities and areas are separated by leaving a certain space between one another instead of
arranging physical blockage.
2.6 Partition
Articles, facilities and areas are separated by arranging physical blockage such as wall, hygienic barrier,
shade or independent room.
Building and site for food processing and other buildings, sites and surrounding environment managed in the
same way.
2.8 Monitoring
Observation or determination carried out according to the preset way and parameter to evaluate whether the
controlling unit is under the controlled state.
Specialized clothes equipped to reduce the contamination risk of food processing personnel on food
according to the requirements of different production areas.
3.1.1 For the plant, areas which have large contamination on food shall not be selected. If a place has
obviously adverse effect which can't be improved by taking measures on food safety and food edibility, the
plant shall not be built in the place.
3.1.2 For the plant, sites where hazardous waste, dust, harmful gas, radioactive substance and other
diffusive contaminants can't be eliminated effectively shall not be selected.
3.1.3 For the plant, regions where flood disaster can easily occur should not be selected; if it's difficult to
keep away, necessary precaution measures shall be designed.
3.1.4 There should not be potential locations with a large number of insect pest breeding around the plant;
if it's difficult to keep away, necessary precaution measures shall be designed.
3.2.1 Potential contamination risk of the surroundings to food production shall be considered and
appropriate measures shall be taken to reduce it to the minimum level.
3.2.2 The plant shall be arranged reasonably; each functional area shall be obviously divided with
appropriate separation or partition measures to prevent cross contamination.
3.2.3 For the road in the plant, concrete, tar or other hard materials shall be paved; necessary measures
shall be taken for vacant land, for example, cement, floor tile or lawn shall be paved to maintain clean
surrounding and prevent raising dust and accumulating water under normal weather.
3.2.4 Plant greening shall be kept a proper distance from the production workshop, and vegetation shall be
maintained periodically to prevent insect pest from breeding.
3.2.6 Living area such as dormitory, canteen or recreation facilities of employees shall be kept a proper
distance or partitioned from the production areas.
4.1.1 Internal design and layout of plant and workshop shall meet the operation requirement of the food
hygiene to avoid cross contamination during food production.
4.1.2 Design of plant and workshop shall be arranged reasonably according to production process to
prevent and reduce the risk of contamination on products.
4.1.3 Operating areas in the plant and workshop shall be divided reasonably according to product
Copyright @ 2015 The Sovereign Group All Rights Reserved
168
characteristics, production process, production characteristics and the requirements of cleanliness in
production process and shall be effectively separated or partitioned. For example: operating areas are
generally divided into clean operating area, quasi-clean operating area and general operating area; or clean
operating area and general operating area, etc. General operating area shall be partitioned from other
operating areas.
4.1.4 Inspection room arranged in the plant shall be partitioned from the production area.
4.1.5 Area and space of the plant shall be corresponding to the productivity to be convenient for equipment
arrangement, cleaning and disinfection, material storage and personnel operation.
The building's internal structure shall be easy for maintenance, cleaning or disinfection and shall be
constructed with appropriate durable materials.
4.2.2 Ceiling
4.2.1.1 Ceiling shall be constructed with nontoxic, odorless materials corresponding to the production
demand and easy for observing cleaning condition; if coatings are directly coated on the inner-layer of the roof
as ceiling, nontoxic, odorless and mold-proof coatings difficult for shedding and easy for cleaning shall be
used.
4.2.1.2 Ceiling shall be easy for cleaning and disinfection, and difficult for condensed water to vertically drip in
the structure to prevent insect pest and mold from breeding.
4.2.1.3 Pipelines of accessories for steam, water and electricity shall not be arranged above the exposed
food; if it's unavoidable, device or measure to prevent dust from scattering and water drop from dripping shall
be provided.
4.2.3 Wall
4.2.3.1 Wall surface and partition shall be constructed with nontoxic, odorless and anti-seepage materials;
wall surface within the range of operation height shall be smooth, difficult for accumulating dirt and easy for
cleaning; if coatings are used, they shall be nontoxic, odorless, mold- proof, difficult for shedding and easy for
cleaning.
4.2.3.2 Wall, partition and ground junctions shall be reasonable in structure, easy for cleaning and effectively
avoid the accumulation of dirt such as the arrangement of smooth and accessible surfaces.
4.2.4.1 Doors and windows shall be closed tightly. Door surface shall be smooth, adsorption-proof,
anti-seepage and easy for cleaning and disinfection. They shall be made of water proof, solid, and
non-deformable materials.
4.2.4.2 Doors of clean operating area, quasi-cleaning operation area and other areas shall be able to timely
be shut down.
4.2.4.3 Window glass shall be made of breakage-proof materials. If simple glass is used, necessary
Copyright @ 2015 The Sovereign Group All Rights Reserved
169
measures shall be taken to prevent contamination on materials, packaging materials and food after glass
breakage.
4.2.4.4 If windows are arranged with sills, their structure shall be able to avoid dust accumulation and be easy
for cleaning. Windows able to open shall be equipped with insect pest prevention window screen easy for
cleaning.
4.2.5 Ground
4.2.5.1 Ground shall be made of nontoxic, odorless, anti-seepage and corrosion-resistant materials. The
ground structure shall be conducive to sewage discharge and cleaning.
4.2.5.2 Ground shall be flat, anti-skid, crack-free and easy for cleaning and disinfection and shall be provided
with appropriate measures to prevent water accumulation.
5.1 Facilities
5.1.1.1 Water supply facilities shall ensure that the water quality, water pressure and water amount meet the
production requirements.
5.1.1.2 The quality of food processing water shall meet the requirements of GB 5749. For food with special
requirements of processing water quality, corresponding requirements shall be met. The quality of food
production water such as indirect cooling water and boiler water shall meet the production requirements.
5.1.1.3 Food processing water and other water such as indirect cooling water, sewage or waste water without
contacting with food shall be transported with completely separated pipelines to avoid cross contamination.
Each pipeline system shall be marked explicitly for distinction.
5.1.1.4 Self-provided water source and water supply facilities shall meet the relevant requirements. Products
used in water supply facilities involving hygienic security of drinking water shall also meet the relevant national
requirements.
5.1.2.1 Drainage system shall be designed and constructed to ensure unblocked drainage and convenient
cleaning and maintenance; it shall adapt to the need of food production and ensure that food, production and
clean water be free from contamination.
5.1.2.2 The inlet of drainage system shall be installed with a device such as a floor drain with water seal to
prevent solid waste from entering and discharged air from escaping.
5.1.2.3 Outlet of drainage system shall be provided with appropriate measures in order to reduce the risk of
insect attack.
5.1.2.4 Indoor drainage shall flow from areas with high cleanliness to those with low cleanliness, and shall be
designed to prevent backflow.
5.1.2.5 Sewage shall be disposed by proper ways before discharge to meet the relevant national
Sufficient specialized cleaning facilities for food, tools and instruments and equipment shall be provided;
where necessary, appropriate disinfection facilities shall be provided. Measures shall be taken to avoid cross
contamination brought by tools and instruments for cleaning and disinfection.
Specialized facilities for storing waste which are reasonably designed, anti-seepage and easy for cleaning
shall be provided; facilities and containers for storing waste in the workshop shall be marked clearly. Where
necessary, facilities for storing waste temporarily shall be arranged in proper site and waste shall be stored
in classes according to characteristics.
5.1.5.1 Changing room shall be arranged at the entrance of production location or production workshop;
where necessary, changing room may be arranged at the entrance of the specific operating area as needed.
The changing room shall be designed to ensure that work clothes, personal clothes and other articles be kept
apart.
5.1.5.2 Facilities for changing shoes (putting on shoe covers) or disinfection facilities for work shoes or boots
shall be arranged as needed at the entrance and necessary place of the production workshop. If disinfection
facilities for work shoes or boots are arranged, their specification and size shall meet the requirements of
disinfection.
5.1.5.3 Restroom shall be arranged as needed; its structure, facilities and internal materials shall be easy to
keep clean; facilities for washing hand shall be arranged at proper place in the rest room. The restroom shall
not be directly connected with areas for food production, packaging or storage.
5.1.5.4 Facilities for washing and drying hand and disinfection shall be arranged at the entrance of clean
operating area; if necessary, facilities for washing hand and (or) disinfection shall be added in the operating
area; for the faucets matched with disinfection facilities, their switches shall be non- manual.
5.1.5.5 Quantity of the faucets for hand washing facilities shall be matched with that of food processing
personnel of the same shift; where necessary, mixer of cold and hot water shall be arranged. Wash basins
shall be made of smooth, water-proof and easy-to-clean materials and shall be designed and constructed to
be easy for cleaning and disinfection. Simple and clear hand washing method shall be marked at visible
position adjacent to hand washing facilities.
5.1.5.6 According to the cleanliness of food processing personnel, where necessary, facilities such as air
shower and shower room may be arranged.
5.1.6.1 Appropriate natural ventilation or artificial ventilation measures shall be taken; where necessary,
natural ventilation or mechanical facilities shall be used to effectively control temperature and humidity of
production environment. For ventilation facilities, air shall not flow from operating areas with low requirements
on cleanliness to those with high requirements on cleanliness.
5.1.6.2 Air inlet position shall be arranged reasonably, and contamination source such as air inlet, air outlet
Copyright @ 2015 The Sovereign Group All Rights Reserved
171
and device for storing outdoor garbage shall be kept an appropriate distance and angle. Air inlet and outlet
shall be equipped with facilities such as mesh enclosure to prevent insect pest from intruding. Ventilation
facilities shall be easy for cleaning, maintenance or replacement.
5.1.6.3 If filtration and purification treatment for air is needed in the production process, air filtration device
shall be added and cleaned periodically.
5.1.6.4 According to production requirements, where necessary, de-dusting facilities shall be installed.
5.1.7.1 Sufficient natural lighting or artificial lighting shall be provided in the plant; luster and luminance shall
meet production and operation requirements; light source shall make it possible that food takes on actual
color.
5.1.7.2 If lighting facilities are needed to be installed above the exposed food and materials, safe lighting
facilities shall be adopted or protection measures shall be taken.
5.1.8.1 Storage facilities corresponding to quantity, storage requirements of products shall be provided.
5.1.8.2 Warehouse shall be made of nontoxic and solid materials; warehouse ground shall be flat and
convenient for ventilation. Warehouse shall be designed to be easy for maintenance and cleaning to prevent
insect pest from hiding and shall be provided with device for preventing insect pest from intruding.
5.1.8.3 Materials, semi-finished products, finished products and packaging materials shall be arranged with
different storage sites or placed in different areas according to different properties and shall be marked
explicitly to prevent cross contamination. Where necessary, warehouse shall be equipped with control facilities
of temperature and humidity.
5.1.8.4 Storing articles shall be kept a proper distance from wall and ground in order to be conducive to
ventilation and articles handling.
5.1.8.5 Detergent, disinfectant, pesticide, lubricant or fuel shall be packaged safely and marked explicitly and
shall be kept apart from materials, semi-finished products, finished products and packaging materials.
5.1.9.1 Appropriate heating, cooling and freezing facilities and facilities for monitoring temperature shall be
equipped according to the characteristics of food production.
5.1.9.2 According to production requirements, facilities for controlling room temperature may be arranged.
5.2 Equipment
Production equipment corresponding to productivity shall be provided and arranged in order according to
process flow to avoid cross contamination.
5.2.1.2.1 Equipment and instruments contacting with materials, semi-finished products and finished
products shall be made of nontoxic, odorless, corrosion-resistant materials difficult for shedding and shall be
easy for cleaning and maintenance.
5.2.1.2.2 Surface of equipment and tools and instruments contacting with food shall be made of smooth,
nonabsorbent materials easy for cleaning, curing and disinfection, and will not react with food, detergent and
disinfectant under normal production and shall be kept in perfect condition.
5.2.1.3 Design
5.2.1.3.1 All production equipment shall make it possible in design and structure to avoid parts, metal chip,
lubricating oil or other contamination factors being mixed into food and shall be easy for cleaning, disinfection,
inspection and maintenance.
5.2.1.3.2 Equipment shall be fixed on the wall or floor without any gap or sufficient space shall remain
between it and ground or wall during the installation to be convenient for cleaning and maintenance.
The equipment used for monitoring, controlling and recording such as pressure gauge, thermometer or
recorder and shall be calibrated and maintained periodically.
Equipment maintenance and repair system shall be established to strengthen the routine maintenance and
curing of equipment; the equipment shall be inspected periodically and the result shall be recorded timely.
6. Hygiene Management
6.1.1 Hygiene management system for food processing personnel, food production and corresponding
assessment standard shall be established; post responsibilities shall be determined to carry out post
responsibility system.
6.1.2 Monitoring system for key control link significant to guarantee food safety shall be established
according to the characteristics of food and hygienic requirements in the production and storage process to be
implemented well and inspected periodically. If any problem is found, it shall be timely corrected.
6.1.3 Hygienic monitoring system for production environment, food processing personnel, equipment and
facilities shall be established to determine the range, object and frequency of internal monitoring. The
monitoring results shall be recorded and filed, and executive condition and effect shall be inspected
periodically so that any problem can be rectified if it's found.
6.1.4 Cleaning and disinfection system and management system for cleaning and disinfection instruments
shall be established. Equipment and tools and instruments before and after cleaning and disinfection shall be
kept apart and safely kept to avoid cross-contamination.
6.2.2 Equipment and tools and instruments for production, packaging and storage, pipeline for production
and contact surface of exposed food shall be cleaned and disinfected periodically.
6.3 Health management and hygienic requirement for food processing personnel
6.3.1.1 Health management system for food processing personnel shall be established and carried out.
6.3.1.2 Personnel involved in food processing shall undergo an annual physical examination check and
obtain a health certificate; they shall accept hygienic training before taking posts.
6.3.1.3 Food processing personnel who suffer from infectious disease of digestive tract such as dysentery,
typhoid, viral hepatitis A and viral hepatitis E, diseases affecting food safety such as active pulmonary
tuberculosis and suppurative or exudative dermatosis, or the personnel whose skin injury has not been healed
shall be transferred to other posts without affecting food safety.
6.3.2.1 The personnel shall handle personal hygiene before entering food production site to avoid
contaminating food.
6.3.2.2 The personnel shall wear clean work clothes when entering the operating area, wash hand and
disinfect as needed; hair shall be hidden in work cap or restraint by hairnet.
6.3.2.3 The personnel shall not wear jewelry and watch and shall not make up, dye fingernails and spray
perfume; they shall not carry or store personal articles irrelevant to food production.
6.3.2.4 After going to the rest room, contacting articles which may contaminate food or engaging in other
activities irrelevant to food production, they shall wash hand and disinfect before engaging in activities Insect
pest control measures shall be prepared and carried out for periodical inspection. Effective measures such as
yarn curtain, gauze, rat guard, fly prevention lamp or wind screen shall be taken in production workshop and
warehouse to prevent rodent or insects from intruding. If trail of insects or rodent is found, its source shall be
traced to eliminate hidden danger.
6.3.3 Visitors
Those who are not food processing personnel shall not enter food production site; if they enter the food
production site under special circumstances, they shall abide by the same hygienic requirements with food
processing personnel.
6.4.1 The building shall be kept in perfect condition and tidy to prevent insect attack from intruding and
breeding.
6.4.2 Insect pest control measures shall be prepared and carried out for periodical inspection. Effective
measures such as yarn curtain, gauze, rat guard, fly prevention lamp or wind screen shall be taken in
production workshop and warehouse to prevent rodent or insects from intruding. If trail of insects or rodent is
Copyright @ 2015 The Sovereign Group All Rights Reserved
174
found, its source shall be traced to eliminate hidden danger.
6.4.3 Plan drawing for insect pest control shall be exactly drawn to mark the positions of mousetrap, glue
board, fly-killing lamp, outdoor bait and killing device of biochemical pheromone.
6.4.5 During the treatment by physical, chemical or biological agent, food safety and the proper food quality
shall not be affected and food contact surface, equipment, tools and instruments and packaging material shall
not be contaminated. Pest control shall be recorded correspondingly.
6.4.6 Before using various kinds of pesticides or other drugs, preventive measures shall be taken to avoid
contamination on persons, food, equipment and tools; in case of contamination carelessly, contaminated
equipment or tools shall be cleaned thoroughly in time to eliminate contamination.
6.5.1 System for waste storage and elimination shall be prepared; for waste with special requirements, its
disposal shall meet the relevant requirements. Waste shall be eliminated periodically; corruptible waste shall
be eliminated as soon as possible; where necessary, waste shall be eliminated timely.
6.5.2 Waste location outside the workshop shall be isolated from food processing site to prevent
contamination; smelly or harmful, toxic gas shall be prevented from escaping; insect pest shall be prevented
from breeding.
6.6.1 The personnel shall wear work clothes while entering the operating areas.
6.6.2 Specialized clothes such as coats, pants, shoes, caps and hairnet shall be equipped according to the
food characteristics and the requirements of production process; where necessary, mask, apron, sleeve or
glove may be equipped.
6.6.3 Cleaning system for work clothes shall be prepared, where necessary, work clothes shall be replaced
timely; during the production, work clothes shall be kept clean and in perfect condition.
6.6.4 Work clothes shall be designed and made to adapt to the requirements of different operating areas to
reduce the risk of cross contamination; position of work clothes pocket and connection fastening shall be
reasonably selected to reduce the contamination risk caused by content or fastening dropping.
Purchasing, acceptance, transportation and storage management system for food material, food additives
and products relevant to food shall be established to ensure that the food materials, food additives and
products relevant to food meet the relevant national requirements. Any substance which may damage
human health and life safety shall not be added to food.
7.2.1 License and qualified certificate of the Supplier for the purchased food materials shall be checked;
food materials without qualified certificate shall be inspected according to food safety standard.
7.2.2 Food materials can't be used until they pass the acceptance. Food materials without passing the
acceptance shall be kept apart from the qualified materials in designated areas and marked obviously and
shall be returned and replaced timely.
7.2.3 Sensory inspection should be conducted before processing and where necessary, laboratory
inspection shall be conducted; once the item indexes involving food safety are found to be abnormal, the food
materials shall not be used and only the verified applicable ones shall be used.
7.2.4 During transportation and storage, the food materials shall be kept away from direct sunlight and shall
be equipped with rainproof and dustproof facilities; according to the characteristics and hygiene requirements
of food materials, they shall also be provided with facilities for insulation, cold storage and fresh keeping.
7.2.5 Transportation tools and vessels of food materials shall be kept clean and be maintained in good
condition and be disinfected where necessary. The food materials shall not be shipped together with toxic and
harmful substance to avoid contamination on food materials.
7.2.6 For warehouse of food materials, management system shall be established and it shall be managed
by specific personnel who are responsible for periodically inspecting the quality and hygienic condition and
timely cleaning bad food materials or those exceeding quality guarantee period. The distribution order of
warehouse shall comply with the principle of "first in first out"; where necessary, it shall be determined
according to the characteristic of different food materials.
7.3.1 License of the Supplier and qualified certificate of products shall be inspected where food additives
are purchased. The food additives can't be used until they pass the acceptance.
7.3.2 The transportation tools and containers of food additives shall be kept clean and be maintained in
good condition and shall be provided with necessary protection to avoid contamination on the food additives.
7.3.3 Storage of food additives shall be managed by specific personnel who are responsible for periodically
inspecting the quality and hygienic condition and timely cleaning the bad food materials or those exceeding
quality guarantee period. The distribution order of warehouse shall comply with the principle of "first in first out";
where necessary, it shall be determined according to the characteristic of food additives.
7.4.1 Products relevant to food such as purchased food packaging materials, containers, detergent and
disinfectant shall be inspected for qualified certificate; those which are carried out with license management
shall also be inspected for the license of the Supplier and those such as food packaging materials can't be
used until they pass the acceptance.
7.4.2 The transportation means and vessels of products relevant to food shall be kept clean and be
maintained in good condition and shall be provided with necessary protection to avoid contamination on food
materials and-cross contamination.
7.4.3 Storage of relevant products relevant to food shall be managed by specific personnel who are
Copyright @ 2015 The Sovereign Group All Rights Reserved
176
responsible for periodically inspecting the quality and hygienic condition and timely cleaning the bad food
materials or those exceeding quality guarantee period. The distribution order of warehouse shall comply with
the principle of "first in first out".
7.5 Other
For packaging or containers of food materials, food additives and packaging materials directly contacting
food, their materials shall be stable, nontoxic, harmless, and difficult to be contaminated and meet hygienic
requirements.
Food materials, food additives and food packaging materials shall be provided with a certain buffer or
cleaning measures for external packaging to reduce the contamination risk.
8.1.1 Hazard analysis method shall be used to define the key link of food safety during production process
and control measures for the key link of food safety shall be taken. In the area of the key link, relevant
documents such as list of ingredients (feeding) and post specifications shall be prepared to implement control
measures.
8.1.2 Hazard Analysis and Critical Control Point system is encouraged to be adopted for the food safety
control during production process.
8.2.1.1 The effective cleaning and disinfection system shall be developed for production equipment and
environment to reduce the risk of microbial contamination according to the characteristics of material, product
and process.
8.2.1.2 Cleaning and disinfection system shall include: cleaning and disinfection area and name of
equipment or instruments; responsibilities of cleaning and disinfection work; detergent and disinfectant;
cleaning and disinfection method and frequency; verification of cleaning and disinfection effect and treatment
for those failing to meet the requirements; cleaning and disinfection work and monitoring record.
8.2.1.3 The cleaning and disinfection system shall be guaranteed to be implemented and recorded faithfully;
the disinfection effect shall be timely verified and it shall be corrected timely in case of any problem.
8.2.1.4 The key control link is determined according to the product characteristics to carry out microbial
monitoring; where necessary, the microbial monitoring procedure of food processing shall be established,
including microbial monitoring of production environment and process product.
8.2.1.5 The microbial monitoring procedure of food processing shall include: microbial monitoring indexes,
sampling points, monitoring frequency, sampling and inspection method, evaluation principles and rectification
measures. The specific items may be developed by reference to the requirements of Appendix A in
combination with production process and product characteristics.
8.3.1 The management system to avoid chemical contamination shall be established; the possible
contamination source and contamination way shall be analyzed and the proper control plan and control
procedure shall be developed.
8.3.2 Use system of food additives and processing aids for food industry shall be established and the food
additives shall be used according to the requirements of GB 2760.
8.3.3 Any non-edible chemical composition except food additives and other substances which may hazard
human health shall not be added during food processing.
8.3.4 On the production equipment, if the movable components which may directly or indirectly contact food
need lubrication, the edible oil or other oil meeting requirements of food safety shall be adopted.
8.3.5 The use system of chemicals such as detergent and disinfectant is established. Except for the
cleaning and disinfection requirement and process demand, the chemicals which may contaminate food shall
not be used and stored in the production site.
8.3.6 All food additives, detergents and disinfectants shall be preserved in proper container and shall be
stored with obvious mark and in classes; during the receiving, they shall be exactly measured and recorded.
8.3.7 Hazardous substances resulting from food production must be monitored and effective measures
must be encouraged and taken to reduce risk.
8.4.1 The management system to avoid contamination of foreign matters shall be established; the possible
contamination source and contamination way shall be analyzed and the corresponding control plan and
control procedure shall be developed.
8.4.2 The measures such as equipment maintenance, hygiene management, site management, outsider
management and processing supervision shall be taken to reduce the contamination risk of foreign matters
such as glass, metal and plastic cement in maximum extent.
8.4.3 Effective measures such as arrangement of screen mesh, collector, magnet and metal checker shall
be taken to reduce the risk of metal or other foreign matters to contaminate food.
8.4.4 During site repair, maintenance and construction, the proper measures shall be taken to avoid foreign
matters, unpleasant smell and chips to contaminate food.
8.5 Packaging
8.5.1 The food packaging shall be able to protect the food safety and quality in maximum extent under
normal storage, transportation and marketing (wholesale and retail) conditions.
8.5.2 Identification shall be checked to avoid misusage where the packaging material is used; and the use
condition of packaging material shall be recorded truthfully.
Copyright @ 2015 The Sovereign Group All Rights Reserved
178
9. Inspection
9.1 The inspection shall be carried out for material and product through self-inspection or by the
consignable food inspection institution with corresponding qualification and the recording system for delivery
inspection of food is established.
9.2 For self-inspection, the corresponding inspection room and inspection capability to inspection items
shall be provided with; the inspection is carried out by the inspection personnel with corresponding
qualification according to required inspection method; the inspection instruments and equipment shall be
inspected periodically.
9.3 The inspection room shall be provided with sound management system to properly preserve the original
record and inspection report of each inspection. Products sampling system shall be established to timely
keep sample.
9.4 Comprehensive consideration shall be taken for factors such as product characteristics, process
characteristics, material control condition to reasonably determine inspection items and frequency so as to
effectively verify control measures during production process. The inspection frequency of net content,
sensory requirements and other inspection items easy to change due to effect of production process shall be
greater than that of other inspection items.
9.5 For the same variety of product with different packaging, inspection items free from effect of packaging
specification and packaging type may be inspected together.
10.1 Proper storage and transportation conditions are selected according to requirements of food
characteristics and hygiene; where necessary, the facilities shall be equipped for insulation, cold storage and
fresh keeping. The food shall not be stored and transported together with toxic, harmful or smelly articles.
10.2 Suitable storage system shall be established and carried out and in case of any abnormality, it shall
be timely treated.
10.3 The containers, tools and instruments and equipment to store, transport and load and unload the
food shall be safe, harmless and clean to reduce the risk of food contamination.
10.4 During the storage and transportation, the direct sunlight, rain, notable temperature and humidity
change and violent impact shall be avoided to prevent the adverse effect on food.
11.1 The product recall system shall be developed according to the relevant national regulations.
11.2 Where the produced food is unconformable with the food safety standard or other inedible
conditions are found, the production shall be stopped immediately and the food already sold in market shall
be recalled; the relevant production operators and consumers shall be notified and the recall and notification
condition shall be recorded.
11.3 The recalled food shall be safely disposed or be destroyed to avoid them flowing into the market
again. For food that is recalled due erroneous labeling, identification, or directions for use that is not in
conformity with food safety standards, corrective measures shall be taken to guarantee the safety of the
product, and explain the situation to consumers once the product is re-launched for sale.
Copyright @ 2015 The Sovereign Group All Rights Reserved
179
11.4 Production batch shall be reasonably divided and recorded and identification shall be carried out
such as product batch No. to be convenient for product traceability.
12. Training
12.1 Training system for relevant post of food production shall be established and the corresponding
training about food safety knowledge shall be carried out for food processing personnel and practitioners
of relevant post.
12.2 The awareness and responsibility of the practitioner to comply with relevant laws, regulations and
standards of food safety and implement management system of food safety shall be promoted and the
corresponding knowledge level shall be improved through the training.
12.3 The annual training plan of food safety shall be developed and implemented according to the actual
demand of different posts of food production and the assessment is carried out; the training record is made.
12.4 Where the relevant laws, regulations and standards of food safety is updated, the training shall be
timely developed.
12.5 The training plan shall be examined and revised periodically and the training effect is evaluated;
and the routine inspection is carried out to ensure the effective implementation of training plan.
13.1 The professional technical personnel and management personnel of food safety shall be allocated
and the management system to guarantee food safety shall be established.
13.2 The management system of food safety shall be corresponding to the production scale, process
level and variety characteristics of food and shall be continuously improved according to actual production
and implementation experience.
13.3 The management personnel shall know about the basic principles and operation specifications of
food safety and shall be able to judge the potential risks and take suitable preventive and corrective
measures to ensure the effective management.
14.1.1 The recording system shall be established to record links of food production such as purchasing,
processing, storage, inspection and marketing (sales) in detail. The record contents shall be complete and true
to ensure that all links from material purchasing to production, to marketing of the product may be traced
effectively.
14.1.1.1 The contents such as name, specification, quantity, supplier's name and contact, and purchase date
of products relevant to food such as food materials, food additives and food packaging materials shall be
recorded truthfully.
14.1.1.2 The contents such as food processing (including process parameter and environmental monitoring),
storage condition of food and inspection batch No., inspection date, inspection personnel, inspection method
and inspection result of the product shall be recorded truthfully.
14.1.1.4 The contents such as name, batch, specification, quantity, recall reason and subsequent rectification
program of recalled food shall be recorded truthfully.
14.1.2 The purchasing inspection record of products relevant to food such as food materials, food additives
and food packaging materials and delivery inspection record of food shall be rechecked and signed by the
record personnel and examiner; the record contents shall be complete. The preservation period shall not be
less than 2 years.
14.1.3 The customer complaint handling mechanism shall be established. As for the written or verbal advice
and complaint proposed by customers, the related management departments of the enterprise shall make
records, find out the reasons and handle them carefully.
14.2 The management system of document shall be established to effectively manage documents so as
to ensure that documents at each relevant location are valid.
14.3 The advanced technology and means (such as information system of electronic computer) are
encouraged to be adopted to carry out record and document management.
A.1 The microbial monitoring during food processing is important means to ensure the food safety and
the tool to verify or evaluate effectiveness of target microorganism control procedure and to ensure the
continuous improvement of whole food quality and safety system.
A.2 This Appendix proposes the key points which shall be considered where the microbial
monitoring procedure of food processing is developed.
A.3 The microbial monitoring of food processing mainly includes the environmental microbial monitoring
and microbial monitoring of process product. The environmental microbial monitoring is mainly used to
judge the hygiene control condition of processing and find out the potential contamination source. Generally,
the environmental monitoring objects include food contact surface, adjacent contact surface to food or food
contact surface and environmental air. The microbial monitoring of process product is mainly used to
evaluate the hygiene control capacity of processing and hygienic condition of product.
A.4 The microbial monitoring of food processing covers microbiology evaluation and evaluation of
cleaning and disinfection effect and microorganism control effect of each link during processing. During
development, the following contents shall be considered:
a) The microbial monitoring of processing shall include the microbial monitoring indexes, sampling points,
monitoring frequency, sampling and inspection method, evaluation principles and treatment for
non-conformance condition.
b) The microbial monitoring indexes of processing shall take the indicator microorganism (such as
aerobic bacteria count, coliform bacteria, yeast or other indicator bacteria) which is able to evaluate the
hygienic condition of processing environment and process control capacity as priority. Where necessary,
the pathogenic bacteria may also be adopted as the monitor index.
c) The microbial monitoring sampling points of processing: sampling points of environmental monitoring
shall be places which are contaminated due to the possible existence or entrance of microorganism. The
sampling points may be determined according to the relevant literature information, experience or
accumulated historical data. The sampling points of process product monitoring plan shall cover all
process products whose microorganism level may change and may affect the product safety and (or)
food quality in the whole processing link, for example, the one behind the key control point controlled by
microorganism. The specific contents may refer to examples detailed in Table A.1.
d) The microbial monitoring frequency of processing: monitoring frequency shall be developed based on
the possible risk of contamination. The reasonable monitoring frequency may be determined according to
the relevant literature information, relevant experience and professional knowledge or accumulated
historical data. The specific contents may refer to examples detailed in Table A.1. The microbial
monitoring of processing shall be dynamic, adjusted according to the data change and contamination risk
of processing and periodically evaluated. For example, where the indicator microorganism monitoring
result is on the high side, the pathogenic bacteria is found in final product, after the significant
e) The sampling and inspection method: generally, coating sampling is the primary of environmental
monitoring and the direct sampling is adopted for process product monitoring. The selection of inspection
method shall be based on the monitor index.
f) The evaluation principles: the judgment shall be carried out according to the certain monitor index limit
and the limit may be determined based on the microorganism control effect and its influence on the
product quality and food safety.
g) The treatment requirements for inconformity condition of microbial monitoring: the monitoring result of
each monitoring point shall meet the monitor index limit and remain stable; where the slight inconformity
appears, measures such as increasing sampling frequency may be adopted to strengthen monitoring;
where the severe inconformity appears, correction shall be carried out immediately and the reason
leading to problem shall be found out at the same time to determine whether the corresponding corrective
measures are taken for microorganism control procedure.
GB 15193.1-2014
1. Scope
This Standard is applicable to the assessment of the safety of chemical, biological and physical factors that may
cause harm to health concerned during food production, processing, storing, transport and selling process.
Assessment objects include food and its raw material, food additives, new food raw materials, irradiated food,
food related products (used for food packaging materials, containers, detergent, disinfectant; and the tools and
equipment used for food production and marketing), and food pollutants.
2.1 It shall provide the test substance’s name, batch number, content, storage conditions, and sources of
raw materials, production processes, quality specifications, character, human recommended (possible)
intake, and other relevant information.
2.2 For single-ingredient chemical substance, the physical, chemical property (including chemical structure,
purity, stability, etc.) of test substance (including impurities when necessary) shall be provided. For mixed
substances (including formulated products), the composition of test substance shall be provided; when
necessary, physical property, chemical property (including chemical name, structure, purity, stability,
solubility, etc.) of all compositions of test substances and relevant data shall be provided.
2.3 If the test substance is formulated product, it shall be the standardized product; its composition
ingredients, proportion and purity shall be the same as the actual application. If the test substance is an
enzyme preparation, it shall, before other compound ingredients are added, use the product as the test
substance.
3.2.1 Genetic toxicity test contents. Bacterial reverse mutation test, mammalian erythrocyte micronucleus
test, mammalian bone marrow chromosome aberration test, mouse spermatogonia or spermatocytes
chromosome aberration test, in-vitro mammalian cell HGPRT gene mutation test, in-vitro mammalian cell TK
gene mutation test, in-vitro carcinogenicity studies (or chronic toxicity and carcinogenicity merge test).
3.2.2 Genetic toxicity test combinations. Generally speaking, these combinations shall comply with the
principle of integrating prokaryotic cells and eukaryotic cells together and integrating in-vitro tests and in-vivo
tests together. The following combinations are recommended in accordance with properties of the test
material and the test purpose:
Combination 1: Bacterial Reverse Mutation Assay: Mammalian Erythocyte Micronucleus Test or Mammalian
Bone Marrow Cell Chromosome Aberration Test, Mouse Spermatogonial / Spermatocyte Chromosome
Aberration Test or Rodent Dominant Lethal Test.
Combination 2:Bacterial Reverse Mutation Assay: Mammalian Erythocyte Micronucleus Test or Mammalian
Copyright @ 2015 The Sovereign Group All Rights Reserved
186
Bone Marrow Cell Chromosome Aberration Test, In Vitro Mammalian Cells Chromosome Aberration Test or
In Vitro Mammalian Cell TK Gene Mutation Test.
Other Optional Genotoxicity Tests: Sex-linked Recessive Lethal Test in Drosophila melanogaster, In-vitro
Mammalian Cells Repair of DNA Damage (Unscheduled DNA Synthesis (UDS)) Tes, In-vitro Mammalian
Cells HGPRT Gene Mutation Test.
4.1 For substances initiated in China, especially those substances whose chemical structures indicate
potential chronic toxicity, genotoxicity or carcinogenicity, or those substances of large output, wide range of
application and large human intake, systematical toxicity tests will be required, including acute oral toxicity
test, genotoxicity test, 90-day oral toxicity test, malformation test, reproductive & developmental toxicity test,
toxicokinetic test, chronic toxicity test and carcinogenesis test (or chronic toxicity and carcinogencity test).
4.2 For derivatives or analogs of which the chemical structure is basically same as that of known substances
(refer to those that have passed safety evaluation and are allowed for use), or the substances that have
safe-use history in some countries and regions, then it may firstly conduct the acute oral toxicity studies,
genetic toxicity test, 90-day oral toxicity test, and teratogenicity test. According to the test results, determine
whether it needs to conduct the toxicokinetic test, reproductive toxicity test, chronic toxicity test and
carcinogenicity test, etc.
4.3 For substances that are known or have use history in several countries, at the same time, the
application organization has the data to prove that the quality specifications of the declared test substance
are consistent with foreign products, then it may firstly conduct the acute oral toxicity test, genetic toxicity
test, and 28-day oral toxicity test. According to the test results, determine whether it needs to further conduct
toxicity test.
4.4 Selection of the safety toxicology assessment test for food additives, new resources of food and
ingredients, food related products, pesticide residue, veterinary drug residue
4.4.1.1 Flavoring
4.4.1.1.1 All the flavorings that have been approved for use or have been formulated for daily acceptable
4.4.1.1.2 If the data is incomplete or is only approved by one of the international organizations, then acute
toxicity test and one of genetic toxicity test combination shall be conducted first; decide whether further test
is needed after preliminary assessment.
4.4.1.1.3 If no data can be referred to and it is not yet allowed to use by international organization, then
conduct the acute toxicity test first, genetic toxicity test and 28-day oral toxicity test. Decide whether further
test is needed after preliminary assessment.
4.4.1.1.4 For single high-purity natural flavoring that is extracted from edible part of animal or plant, if the
chemical structure and relevant data do not show un-safety, then toxicity test is generally not required.
4.4.1.2.1 For enzyme preparations that have long history of safe consumption and that are produced from
edible parts of animals or plants, if the World Health Organization has announced the acceptable daily intake
(ADI) or ADI is not required to be specified or several countries have approved the use, on the basis of
providing relevant proving.
4.4.1.2.2 For enzyme preparations obtained from other sources: if relatively complete toxicology data is
available, and WHO has defined the acceptable daily intake or it is not necessary to define the acceptable
daily intake, or the preparation has been approved for use in several countries,it is required to carry out the
acute oral toxicity test and the genotoxicity test in the case the preparation’s quality complies with
corresponding international quality standards, and it is required to carry out the acute oral toxicity test, the
genotoxicity test, and the 28-day oral toxicity test in the case the preparation’s quality does not comply with
corresponding international quality standards,and the question whether to execute other toxicity tests
depends on the results of the tests required.
4.4.1.2.3 For enzyme preparations obtained from other sources: if the preparation is a new species, it is
required to carry out the acute oral toxicity test, the genotoxicity test,the 90-day oral toxicity test and the
malformation test first for preliminary assessment,and whether to carry out further tests depends on the
results of the preliminary assessment; if the preparation has been approved for use in one country and the
WHO has not defined the acceptable daily intake or no complete data available, it is required to carry out the
acute oral toxicity test, the genotoxicity test, the 28-day oral toxicity test,and whether to carry out further
tests depends on the results of the tests required.
4.4.1.2.4 Testing on enzyme preparations produced by transgene should comply with applicable regulations
on management of transgenosis of the state.
4.4.1.3.1 If relatively complete toxicology data is available, and WHO has defined the acceptable daily intake
or it is not necessary to define their acceptable daily intake, or the additive has been approved for use in
several countries,it is required to carry out the acute oral toxicity test and the genotoxicity test in the case
the additives’ quality complies with corresponding international quality standards, and it is required to carry
out the acute oral toxicity test, the genotoxicity test, and the 28-day oral toxicity test in the case the additives’
quality dose not comply with corresponding international quality standards,and the question whether to
execute other toxicity tests depends on the results of the tests required.
4.4.1.3.3 For single components prepared from animals, plants, and microorganisms, and high purity food
additives, if the component/additive is a new species, it is required to carry out the acute oral toxicity test, the
genotoxicity test, the 90-day oral toxicity test and the teratogenicity test first for preliminary assessment,
and whether to carry out further tests depends on the results of the preliminary assessment; if the
component/additive has been approved for use by an international organization or in one country it is
required to carry out the acute oral toxicity test, the genotoxicity test and the 28-day oral toxicity test,and
whether to carry out further tests depends on the results of the tests required
It shall be evaluated in accordance with "New food raw material declaration and
acceptance provisions" (State-Health-Food-Announcement [2013] 23).
It shall be evaluated in accordance with "Food related product new varieties declaration and acceptance
provisions" (Health-Supervision-Announcement [2011] 49).
It shall be evaluated in accordance with "Veterinary drug before-clinical toxicology evaluation test guidelines"
(The People's Republic of China, Ministry of Agriculture Bulletin No. 1247).
Understand the degree of toxicity, property and possible target organ of test substance; provide basis for
selection of dose and toxicity observation index for further toxicity test; classify the acute toxicity dosage
according to LD50.
Screen the genetic toxicity of test substance and whether it has potential carcinogenesis and cell
mutagenicity.
On the basis of the acute toxicity test, understand more about the nature of the test substance’s toxicity, the
dose-response relationship and possible target organs, so as to obtain the 28-day oral not-observed
adverse effect dose; preliminarily evaluate the safety of the test substance; and provide the basis for
Copyright @ 2015 The Sovereign Group All Rights Reserved
189
selecting longer-term toxicity and chronic toxicity test dose, observation indicators, toxicity endpoint for next
step.
Alternative tests (at least one is in-vivo test). If the additional 2 alternative tests are negative, it may proceed
to the next toxicity test; if 1 item is positive, it shall give up that the test substance can be used in food.
The test is to determine whether a test substance has teratogenicity and development toxicity,and define
the test substance’s NOAEL(No Observed Adverse Effect Level) for teratogenicity and development toxicity.
The test is to understand how a test substance toxic affects the laboratory animal breeding and its offspring
growth, in terms of gonadal function, estrous cycle, mating behaviour, pregnancy, childbirth, breastfeeding
and weaning, and its offspring reproductive and development. After obtaining the unobserved harmful
effects dose levels by the test substances, it provides the scientific evidence of developing the preliminary
population safe lifting limits standard.
The test is to explain how a test substance is absorbed and distributed in vivo and how soon will be excreted
and other related information, to provide basis for selection of suitable germline of experimental animals
used in the chronic toxicity test, and to reveal the formation of metabolites.
The test is to explain a test substance’s toxicity and carcinogenicity of long-term exposure, to define the test
substance’s NOAEL, and to provide basis for the final assessment for application in foods and the
determination of HBGV (health-based guidance values).
Generally speaking, if a test substance’s LD50 (Lethal Dose, 50%) is less than 100 times of the human
recommended (possible) intake, the substance should not be used in food, and no further toxicology tests is
necessary.
5.2.2.1 It is very likely that the test substance has genotoxicity and carcinogenicity if the results of two or
more tests in the genotoxicity test combination are positivethe, and the substance should not be used in food
if so.
5.2.2.2 If the result of one test in the genotoxicity test combination is positivethe,two more optional tests
(one in vivo test at least)shall be selected and carried out. If the results of the tow optional tests are both
positive, further toxicity tests shall be carried out;if the result of one optional test is positive, the test
substance should not be used in food.
For test substances only the acute toxicity test, genotoxicity test and 28-day oral toxicity test are required to
be carried out, a preliminary assessment could be obtained combining with results of other tests, if no
evident toxicity is observed in the acute toxicity test, genotoxicity test and 28-day oral toxicity test; and
further toxicity tests should be carried out if evident toxicity is observed, especially
a dose-response relationship exists.
According to the not-observed adverse effect dose obtained by the test to conduct assessment, the
principle is:
a) If not-observed adverse effect dose is less than or equal to 100 times of recommended (possible)
human-intake, it indicates stronger toxicity; it shall give up that the test substance can be used in
food;
b) If not-observed adverse effect dose is more than 100 times but less than 300 times, it shall conduct
chronic toxicity test;
c) If not-observed adverse effect dose is more than or equal to 300 times, then chronic toxicity test is
not required; it may proceed to safety assessment.
According to the test results, evaluate if the test substance is the teratogenic substance to laboratory
animals. If teratogenic test result is positive, then reproductive toxicity and reproductive-developmental
toxicity test shall not be continued. For other developmental toxicities that are observed in teratogenicity test,
it shall combine with 28-day and (or) 90-day oral toxicity test results to conduct the assessment.
According to the not-observed adverse effect dose obtained by the test to conduct assessment, the
principle is:
a) If the NOAEL is lower than or equal to 100 times of the human recommended (possible) intake, the
test substance should not be used in foods.
b) If the NOAEL is higher than 100 times but lower than 300 times of the human recommended
(possible) intake, the chronic toxicity test should be carried out.
c) If the NOAEL is higher than 100 times or equal to 300 times of the human recommended (possible)
intake, a safety assessment could be obtained without carrying out the chronic toxicity test.
5.2.7.1 The principle for assessment according to the NOAEL obtained in the chronic toxicity test is as
follows:
a) If the NOAEL is lower than or equal to 50 times of the human recommended (possible) intake, the
b) If the NOAEL is higher than 50 times but lower than 100 times of the human recommended
(possible) intake,the question whether the test substance could be used in foods depends on the
safety assessment.
c) If the NOAEL is higher than 100 times of the human recommended (possible) intake, the test
substance allowed to be used in foods.
5.2.7.2 The principle to analyse the result of the carcinogenesis test according to the incidence, incubation
period and multiplicity determined in the carcinogenesis test is as follows(If one or more of the following
conditions are met , the result of the carcinogenesis test could be regarded as positive; if
a dose-response relationship exists, it could be more certain about the positive result.):
b) Cancer occurs among animals both of the test group and the control group, but the incidence of the
test group is higher.
c) The multiplicity of cancer is evident in the test group, while no multiplicity exists or only seldom
animals have gotten multiple cancer in the control group.
d) There is no evident difference in the incidence between the test group and the control group, but
cancer occurred earlier in the test group.
5.2.8 Others
If the highest dosage of the test substance used as feed additive(no more than 10% of the feed, in principle)
or the dosage after concentration (liquid test substances)is lower than the required times of the human
recommended (possible) intake specified according to the NOAEL,a safety assessment could be made
combining results of other toxicity tests and the actual intake.
6.1 Test indicators’ statistical significance, biological significance and toxicological significance
For the abnormal changes of some indicators in experiment, it shall, according to if there are statistical
differences between experimental-group and control-group’s indicators; if there is dose-response
relationship; the horizontal comparison of similar indicators; and consistency of both sexes and of the
historic control value range of that laboratory; etc., comprehensively consider if the indicator difference has
biological significance. And further judge if there is toxicological significance. In addition, if some tumor is
found in experimental-group but not in control-group, even it has no statistical significance with the
control-group, it still needs to be paid attention to.
It shall consider that, when the given test substance is too high, it may affect nutrient intake and
bioavailability, so as to cause some toxicology performance, rather than that the toxicity is caused by the test
substance.
When conducting analysis and assessment to toxic effects of experimental animals that are caused by the
test substance, it shall consider that, at the same dose level, the toxic effects change along the time.
For the foods eaten by pregnant women, nursing mothers or children, it shall specially pay attention to its
embryo toxicity or reproductive-developmental toxicity, neurotoxicity and immunotoxicity etc.
Due to the species difference between human being and animal, while assessing the food safety, response
data of human being after contacting test substances shall be collected as much as possible, such as
occupational contact and accidental contact, etc. Under the condition of ensuring safety, human tasting test
can be considered in accordance with relevant regulations. And volunteer testees’ toxicokinetics or
metabolism data is of important significance to deduct the animal test result to human being.
The various animal toxicity tests and in-vitro test systems listed in this Standard are the most important data
that can be obtained under the current management (regulations) toxicological assessment level; it is also
the main basis for safety assessment. When test result is positive, and the result judgment is involved in
whether the test substance could be applied in food, the repeatability of result and dose-response
relationship shall be considered.
It is the safety coefficient. When deducting the animal toxicity test result to human being, because there are
biological differences among animal, human being, and human individual, uncertainty coefficient is usually
100; however, it may comprehensively consider the number of safety coefficient according to the test
substance’s raw material source, physiochemical property, degree of toxicity, metabolism characteristic,
accumulation, contacted human-group scope, usage amount in food and possible intake for human being,
application scope and function, and other factors.
Toxicokinetic test is an important aspect for toxicological assessment to chemical substances, because
different chemical substances or dose amount often have significant impact to the differences of
toxicokinetic or metabolism. In toxicity test, the animal species with the same metabolism method and mode
as human being shall be, in principle, applied as much as possible for test. Studying the difference of test
substance’s absorption, distribution, excretion and biotransformation on animal and human being has
important significance on deducting the animal test results to human being and reducing the uncertainty.
While conducting final assessment, the physiochemical property, structure, degree of toxicity, metabolism
characteristic, accumulation, contacted human being scope, usage amount and usage scope in food,
recommended (possible) intake for human being, and other factors of test substance shall be
comprehensively considered; For the substances that have been applied in food for a relative long-time,
they are of great significance to the epidemiology investigation for contact people; however, it is usually
difficult to obtain the reliable data on dose-response relationship. For new test substances, only animal test
Copyright @ 2015 The Sovereign Group All Rights Reserved
193
and other test study data can be relied on. However, even if there are complete and detailed animal test data
and some human being contact epidemiology study data, it is still hard to make assessment that it could
guarantee every person’s safety due to the different species of human being and individuals. The so-called
absolute safety actually does not exist. It shall comprehensively balance between that it may possibly cause
harm to human-body health and it may provide benefits; on premise of food safety, the basis of safety
assessment is not only the result of safety toxicology test, but also relates to the then-level of science,
technological conditions, socio-economy, and cultural factors. Thus, along the time, the development of
social economy, scientific and technological progress, it is necessary to re-assess the test substances that
have previously passed the assessment.
GB 5009.3-2010
This standard will replace GB/T5009.3-2003 Determination of Moisture in Foods and GB/T14769-1993
Testing Methods for Moisture in Foods.
- Amended the range of tempe rature for the direct drying method;
- Clarified the units of measurement used in the first and second method calculation formula;
- GB/T5009.3-1985, GB/T5009.3-2003
- GB/T14769-1993.
1. Scope
The direct drying method in this standard is applicable for the determination of moisture in foods without or
with minimal volatile substances under the 101oC~105oC temperature range and it is not applicable for
samples with moisture level less than 0.5g/100g. Applicable food categories include grains and its products,
aquatic products, soy products, dairy products, meat products, preserved (brine) vegetables, etc.
Depressurized drying method applies to the determination of moisture in foods that can be easily broken
down, e.g. sugar, monosodium glutamate (MSG), but it is not applicable to testing of candies with
supplementary ingredients added during production, e.g. milk candies, gummies as well as samples with
moisture content lower than 0.5g/100g.
Distillation method applies to the determination of moisture in foods with relatively higher volatile substance
content, e.g. fats, spices, but it is not applicable to samples with moisture content lower than 1g/100g.
Karl Fischer method applies to the determination of moisture in foods; specifically it is applicable to foods
with samples with moisture content higher than 1.0×10-3g/100g, while Karl Fischer coulometry applies to
samples with moisture content higher than 1.0×10-5g/100g.
2. Principle
Leveraging on the physical properties of moisture in foods, determine the sample’s loss of mass (includes
hygroscopic water, partially crystalized water and substances that may evaporate under certain conditions)
during the drying process, adopting the evaporation method at temperature 101oC~105oC, 101.3kPa (1
Atm). Calculate the moisture content by comparing the sample mass values before and after the drying
process.
All reagents used in this method are analytically pure (AR) unless otherwise stated.
3.3 Hydrochloric Acid Solution (6mol/L): Measure and extract 50mL hydrochloric acid, then dilute by adding
water till 100mL volume.
3.4 Sodium Hydroxide Solution (6mol/L): Weigh and extract 24g sodium hydroxide, add water to fix and
dilute till 100mL volume.
3.5 Marine Sand: Take marine sand or river sand washed off of mud/soil with water and boil the sand in
hydrochloric acid (prepared as in 3.3) for 0.5h. Thereafter, neutralize the acidity with water, then boil again
Copyright @ 2015 The Sovereign Group All Rights Reserved
197
with sodium hydroxide solution (prepared as in 3.4) for another 0.5h. Neutralize with water, dry at 105oC and
set aside for use later.
5. Analysis Procedures
5.1 Solid Sample: Take a clean aluminum or glass flat-shaped weighing bottle and place it in a
101oC~105oC drying oven for 1.0h with its cap slanted around the side of the bottle. Thereafter, place the
bottle in a dryer to cool for 0.5h, weigh it and repeat the dry/cool and weigh process until the difference
between 2 consecutive measurements do not exceed 2mg; set this as the equilibrium mass. Weigh and
extract 2g~10g (precision 0.0001g) of samples that have been quickly grinded into fine particles of size less
than 2mm (samples that cannot be properly grinded should be cut into finer pieces as much as possible) and
evenly mixed them, then place samples into the abovementioned bottle. Samples with thickness not
exceeding 5mm are considered loose samples and further processing is not required. However, for samples
with thickness more than 10mm, cover these with cap, make record of the precise mass of the bottle with the
samples and then place it into 101oC~105oC drying oven for 2h~4h with its cap slanted around the side of
the bottle. Once drying is completed, cover with cap, remove from oven, then place it into the dryer to cool
for 0.5h and weigh again. Thereafter, place the bottle into 101oC~105oC drying oven for about 1h, remove,
place it into the dryer to cool for 0.5h and weigh. Repeat the oven, dryer and weigh operation until the
difference between 2 consecutive measurements do not exceed 2mg; set this as the equilibrium mass.
Note: Use the final weighing value recorded for the final calculation with the 2 equilibrium mass values.
5.2 Semi-solid or Liquid Sample: Take a clean weighing bottle, add 10g marine sand and a small glass rod
within, then place bottle into 101oC~105oC drying oven for 1.0h, remove, place it into the dryer to cool for
0.5h and weigh; repeat operations till equilibrium mass is attained. Thereafter, weigh and extract 5g~10g
samples (precision 0.0001g) and place them into an evaporating dish. Use a small glass rod to stir and mix
evenly and then place the dish on a boiling water bath so as to evaporate all its water content, stirring and
wiping the bottom of dish of water droplets whenever necessary. Place dish in 101oC~105oC drying oven for
4h, cap and remove, then transfer into a dryer to cool for 0.5h and weigh thereafter. Operations after this will
be similar to instructions in 5.1 from “Thereafter, place the bottle into 101oC~105oC drying oven for about
1h……” onwards.
In formula:
m2 – Mass of weighing bottle (with marine sand and glass rod) and samples after the drying process, units
in g;
Calculation results should retain 3 significant figures when moisture content ≥ 1g/100g; calculation results
should retain 2 significant figures when moisture content < 1g/100g.
7. Precision
Absolute discrepancies between 2 independent test results conducted under iterative conditions should not
exceed 5% of their arithmetic mean value.
8. Principle
Leveraging on the physical properties of moisture in foods, determine the sample’s loss of mass during the
drying process, adopting the depressurized drying method, heating up to temperature 60oC±5oC after
reaching 40 kPa~53 kPa. Calculate the moisture content by comparing the sample mass values before and
after the drying process.
10.1 Preparation of Samples: Weigh and extract powdered and crystal form samples directly for tests; larger
hard candy samples should be crushed into finer chunks using a mortar and mixed evenly before use.
10.2 Test: Take a weighing bottle that has attained equilibrium mass and place approximately 2g~10g
(precision 0.0001g) samples into the bottle. Thereafter, place the bottle with samples into the vacuum drying
oven and connect the oven to a vacuum pump, drawing out the air inside the vacuum oven (required
pressure at 40kPa~53kPa) while increasing the temperature simultaneously to the required temperature of
60oC±5oC. Close the piston of the vacuum pump, stop the vacuuming process but maintain the vacuum
drying oven at a certain temperature and pressure. After 4h, open the piston and allow air to gradually fill the
vacuum drying oven through the dryer equipment, opening the oven only when the pressure inside the oven
restores itself to normal conditions. Remove the weighing bottle, place it into a dryer for 0.5h and weigh it.
Repeat the previous dryer operation until the difference between two consecutive measurements do not
exceed 2mg; set this as equilibrium mass.
Same as Section 6.
12. Precision
Absolute discrepancies between 2 independent test results conducted under iterative conditions should not
exceed 10% of their arithmetic mean value.
13. Principle
Leveraging on the physical and chemical properties of moisture in foods, determine the moisture content in
samples according to the volume of moisture and toluene or xylene in foods extracted during the distillation
extraction process using a moisture measuring device. This method applies to food that contains relatively
higher content of other volatile substances, e.g. fats, spices.
Toluene or Xylene (Chemically Pure): Take toluene or xylene, saturate with water and remove the layer of
water after the saturation process. Thereafter, conduct distillation and collect the distillate for use later.
15.1 Moisture Measuring Device: Illustrated as in Diagram 1 (attached with adjustable electro-heating
jacket). Moisture receiving tube specifications: volume 5mL, smallest scale 0.1mL, volume error smaller than
0.1mL.
1. 250mL Distillation Bottle; 2. Moisture Receiving Tube, with Scales; 3. Condensation Tube
Accurately weigh and extract samples (should ensure the final water distillate should be 2mL~5mL, but
maximum volume of samples used should not exceed 2/3 of that of the distillation bottle), and place them in
a 250mL conical flask. Add 75mL newly distillated toluene (or xylene), connect the condensation tube and
the moisture receiving tube. Channel the toluene from the top end of the condensation tube into the device
until the moisture receiving tube is full.
Slowly heat up the distillation liquid, producing 2 drops of distillates per second. Increase the distillation
speed to 4 drops per second when most of the moisture have been distillated out of the distillation liquid.
Add toluene from the top end of the condensation tube to flush and clean the tube when the moisture have
been fully distillated and the volume of water in the receiving tube does not increase anymore over time. If
there is water droplets formed on the walls of the condensation tube, a copper wire with a small rubber head
can be used to wipe these droplets off. Continue the distillation process for a short while until the water
droplets stopped forming on the top end of the receiving tube and condensation tube. Distillation end point
will be set when the level of distillate remains constant for 10mins. Read off the volume marking.
𝑉𝑉
𝑋𝑋 = 𝑋𝑋 100 ………………………………………………… (2)
𝑚𝑚
In formula:
X – Moisture content in the samples, units in mL/100g (or the weight of water at 20oC, density 0.998,
20g/mL);
Present the arithmetic mean value of 2 independent test results under iterative test conditions as the final
result, in 3 significant places.
18. Precision
Absolute discrepancies between 2 independent test results conducted under iterative conditions should not
exceed 10% of their arithmetic mean value.
19. Principle
According to the chemical reaction that can happen between iodine and water, sulfur dioxide; when pyridine
and methanol coexist, 1 mol of iodine will react with 1 mol of water, as illustrated by the chemical formula
below:
Karl Fischer moisture determination method can be further distinguished into Coulomb’s method and
titration method. Iodine used in Coulomb’s method is produced through chemical reaction, i.e. if the
electrolyte solution contains water, the iodine produced from the process will chemically react according to
the chemical reaction formula with a 1:1 ratio. Once all the water molecules have went through the
abovementioned chemical reaction, excess iodine will form around the anode region and the reaction will
stop entirely. Iodine used in the titration method is added as a titrant, with the concentration of the iodine
solution known. From there, moisture content in the tested substance can be calculated based on the
amount of iodine consumed in accordance to the volume of titrant solution consumed during the process.
Add a certain volume of methanol (so as to fully immerse the platinum electrodes) into the reaction bottle,
then titrate with Karl Fischer reagent while stirring till the predetermined titration end point. Add 10mg water
(precision 0.0001g), titrate till the predetermined titration end point and make record of the volume (V) of Karl
Fischer reagent used in the process. Karl Fischer reagent titer can be calculated according to formula (3):
M
T= V
…………………………………………………….. (3)
In formula:
V – Volume of Karl Fischer reagent consumed by the water in the titration process, units in mL.
Crushable solid samples should be crushed into finer particles as much as possible, and mixed evenly
before use. Samples that are hard to crush/grind should be cut into smaller pieces.
Add a certain volume of methanol or the solvent specified for use in the Karl Fischer device into the reaction
bottle so as to fully immerse the platinum electrodes and then use the Karl Fischer reagent while stirring to
titrate to the predetermined titration end point. Swiftly add the samples that can dissolve in the
abovementioned solution with ease into the titration cup; for samples that may not dissolve easily in the
solution, they should be added into the titration cup under heated condition or if other solvents that assist the
dissolving process have been added. Titrate to the predetermined end point. The Coulomb’s method is
recommended for samples with moisture content more than 10μg and volume more than 100μg. For
samples that may require a substantially longer time for the titration process, the potential drift value should
be deducted from the results.
Add a certain amount of solvent consistent with the amount of samples added to the titration cup and titrate
to the predetermined titration end point. Set it aside and let it settle for not less than 10mins before titrating to
the end point again. The volume change between the two titration operations per unit time is the drift value
(D).
Moisture content in solid samples can be calculated based on formula (4), while moisture content in liquid
samples can be calculated based on formula (5).
In formula:
V1 – Volume value of Karl Fischer reagent in the titration process, units in mL;
Calculation results should retain 3 significant figures when moisture content ≥ 1g/100g; calculation results
should retain 2 significant figures when moisture content < 1g/100g.
24. Precision
Absolute discrepancies between 2 independent test results conducted under iterative conditions should not
exceed 10% of their arithmetic mean value.
__________________________
GB 4789.2-2010
1. Scope
This Standard defines the determination method of aerobic plate count in foods.
This Standard is applicable to the determination method of aerobic plate count in all kinds of foods.
The aerobic plate count obtained from 1ml (or 1g) of sample under certain cultivation conditions (such as
the ingredients of culture medium, cultivation temperature and time, pH, and aerobic, etc) after proper
treatment.
3.5 Homogenizer.
3.6 Oscillator.
3.7 Sterile pipette: 1ml (with a scale of 0.01ml), 10ml (with a scale of 0.1ml) or micropipette and tips.
4.1 Agar Culture Medium for plate count: please refer to Appendix A.1.
For the examination procedures of aerobic plate count, please refer to Fig.1.
6. Operation Procedures
6.1.1 Solid and semi solid samples: measure 25g sample into a sterile homogenizing cup containing
225ml phosphate buffer solution or normal saline solution, homogenize with 8000-10000r/min for 1-2min,
or place into sterile homogenizing bag containing 225ml diluent, beating with slaping type homogenizer for
1min to 2min, and then formulate into 1:10 sample solution.
6.1.2 Liquid Sample: Measure 25ml sample with sterile pipette into a sterile conical beaker containing
225ml phosphate buffer solution or normal saline solution (proper amount of sterile beads are placed in
the beaker in advance), and then homogenize and formulate into 1:10 sample solution.
6.1.3 Absorb 1ml of 1:10 sample solution with 1ml sterile pipette or micropipettor, drip the solution into
the sterile tube containing 9ml diluent along the wall of the tube (it is noted that the tip of the pipette shall
not touch the diluent solution surface), shake up the test tube or place a piece of sterile pipette, blow
repeatedly to homogenize, and then formulate into 1:100 sample solution.
6.1.5 As per the estimation of contamination status of samples, select 2 to 3 sample solutions with
proper dilution (for liquid sample, original liquid shall be applied), when carrying out the escalating 10 times
series of dilution, for each dilution, 1ml of sample solution is placed into two sterile plates. At the same
time, measure 1ml of diluents into two sterile plate respectively to serve as blank controls.
6.1.6. Timely cool down the agar culture medium plates with 15-20ml content in each plate to 46C(which
are placed into 46±1C water bath), decant the plates, and then rotate the plates to homogenize.
6.2 Cultivation
6.2.1 After the solidification of agar, turn the plates up-side-down, cultivate at 36±1C for 48h±2h. For
aquatic products, cultivate at 30±1C for 72h±3h.
6.2.2 If the samples possibly contain bacteria that could spread growing on the surface of agar culture
medium, a thin layer of agar culture medium is covered on the agar surface after solidification (about 4ml),
and then turn the plate up-side-down after solidification, and cultivate it as per 6.2.1.
It could be observed with naked eyes, apply magnifying glass or bacteria colony counter when necessary,
and record the dilution times and corresponding plate count. Plate count number is represented by
colony-forming units (CFU).
6.3.1 Select the plates for total plate count with colony number between 30-300CFU, and without
spreading growth on the plate. For plate with plate count under 30CFU, the number of colony is recorded,
while for plate count over 300, it shall be recorded as uncountable. For each dilution degree, the average
number of two plates shall be applied.
6.3.2 For those plates with large piece of colony growing, they shall not be applied. However, the plates
without large piece of colony growth shall be applied for plate count; If the piece of colony covers less than
one half of the plate area, and the colonies on the remaining half of the plate area scatter evenly, it shall be
counted of this half of the plate and then multiply by 2, to represent the entire plate count.
6.3.3 When there occurs chain like growth on the plate without evident border line between colonies on
the plate, each chain shall be calculated as one colony.
7.1.1 If there is only one dilution degree whose plate count fall in the proper counting scope, the
average plate count of both plate shall be calculated, and then multiply the average value by
corresponding dilution times, to serve as the total plate count in one gram (or ml) of sample.
7.1.2 If there are two continuous dilution degrees whose plate count falls in the proper counting scope,
they shall be calculated as in Formula (1):
∑ C- The total number of colonies on the plates (including the plates within the range of proper plate count;
N1 - The number of colonies on the plates of the first proper dilution degree;
N2 - The number of colonies on the plates of the second proper dilution degree;
Example:
The values mentioned above are round-up, and then represented as 25000 or 2.5x104.
7.1.3 If the colony numbers on the plates of all dilution degrees are all over 300CFU, count the plates
with the maximum dilution degree. For other plates, they shall be recorded as uncountable, and the results
shall be obtained by multiplying the average colony number by the maximum dilution times.
7.1.4 If the colony numbers on the plates of all dilution degree are all less than 30CFU, it shall be
calculated by multiplication of average colony number on the minimum dilution degree plates by the
dilution times.
7.1.5 If, for plates of all dilution degrees (including the original liquid samples), there is no colony growth,
then it shall be calculated as multiplying the minimum dilution degree by a factor smaller than 1.
7.1.6 If, for plates of all dilution degrees, the colony number falls outside the range between 30CFU and
300CFU, part of which are less than 30CFU or more than 300CFU, then it shall be calculated for the plates
whose colony number is closest to 30CFU or 300CFU, as the average colony number multiply by dilution
times.
7.2.1 When the plate count falls within 100CFU, it shall be rounded up and reported as interger.
7.2.2 When the plate count is larger than or equal to 100CFU, the third digit shall be rounded up, and
take the first two digits, while the following digits are replaced by 0; it could also be indicated as
exponential of 10CFU, round-up and then take the two significant digits.
7.2.4 When there are colonies growing on the blank control, the examination result is invalid.
7.2.5 For sampling by weight, CFU/g is applied as the report unit, while for sampling by volume,
CFU/ml is applied as the report unit.
Tryptone 5.0g
Glucose 1.0g
Agar 15.0g
pH 7.0±0.2
KH2PO4 34.0g
pH 7.2
GB 4789.3-2010
This standard substitutes GB/T 4789.3-2008 Food hygiene microbiological examination: Enumeration of
coliforms
Compared with GB/T 4789.3-2008, the main modifications of this standard are as follows:
- Modify Chinese-English titles in the standard;
- The scope of plate colony counts in “Method 2 Coliform Plate Counts” is modified to
“15 CFU�150 CFU”;
- Delete “Method 3 Coliform PetrifilmTM Method”
The Annex A and Annex B here of the standard are informative annex. The releases of all editions substituted
by this Standard are as follows:
- GB 4789.3-1984, GB 4789.3-1994,GB /T 4789.3-2003,GB /T 4789.3- 20080
1. Scope
2.1 Coliforms
A cluster of concurrently aerobic and anaerobic gram negative sporeless bacilli which can ferment lactose
and generate acid and gas if cultured in 360 for 24 hours.
3. Devices Requirements
Devices and materials except conventional sterilizing and culturing devices for microbiological laboratory are
as follows:
3.5 Homogenizer
3.6 Oscillator
3.7 Aseptic suction tube: 1ml (with 0.01ml graduation), 10ml (with 0.1ml graduation) or micro pipettor and
sucker
4.1 Lauryl sulfate tryptose (LST) broth: See Chapter A.1 of Annex A
4.3 Violet red bile agar (VRBA): See Chapter A.3 of Annex A
5. Examination Procedures
6. Operating Steps
6.1.1 Solid and semi-solid samples: Weigh and take 25g sample, put it in an aseptic homogenizing cup
which contains 225ml phosphate buffer solution or physiological saline, and homogenize it 8000r/min to
10000r/min for 1 to 2 minutes; or put it in an aseptic homogenizing bag which contains 225ml phosphate
buffer solution or physiological saline and homogenize it by flapping with a smack type homogenizer for 1 to
2 minutes to get 1:10 homogenous sample liquor.
6.1.2 Liquid samples: Suck 25ml sample with an aseptic suction tube, put it in an aseptic conical flask
(with a certain number of aseptic glass beads placed inside beforehand) which contains 225ml phosphate
buffer solution or physiological saline, and blend the solution properly to get 1:10 homogenous sample
liquor.
6.1.4 Suck 1ml 1:10 homogenous sample liquor with a 1ml aseptic suction tube or micro pipettor, empty it
in an aseptic test tube (attention: the pointed end of test tube or sucker should not touch the diluting liquid)
which contains 9ml phosphate buffer solution or physiological saline slowly along the tube wall, jolt the test
tube or beat upon it with a 1ml aseptic suction tube so that it will be homogenized properly to get 1:100
homogenous sample liquor.
6.1.5 According to estimation of sample pollution, make homogenous sample liquor series diluted by 10
times and above as per the above-stated operating steps. For every increased diluting degree, replace one
1ml aseptic suction tube or sucker. From preparation of homogenous sample liquor to completion of
inoculation, the whole process should be within 15 minutes.
For every sample, select homogenous sample liquors with three suitable consecutive dilution degrees (stock
solution may be chosen in case of liquid sample), and for every dilution degree, inoculate 3 tubes of lauryl
sulfate tryptone (LST) broth, 1ml each tube (if more than 1ml is inoculated, double LST broth should be
adopted). Make them cultured in 360±10 for 24h ± 2h and observe whether bubbles are generated in the
tubes; if there is no any bubble, make them cultured for 48h±2h in total. Tubes without bubbles are coliform
negative and tubes with bubbles go through secondary fermentation test.
Take 1 circle of cultures from each of all LST broth tubes which ferment and generate gas within 48h±2h
respectively with an inoculation ring, transfer-inoculate them to brilliant green lactose bile (BGLB) broth,
culture them in 360±10 for 48h±2h, observe bubble- generation. Tubes which generate bubbles are
recorded as coliform positive.
According to the number of tubes which are coliform positive verified through 6.3, search the MPN Table
(see Annex B) to report coliform MPN counts in every gram (or ml) of sample.
7. Examination Procedures
8. Operating Steps
8.2.1 Select 2 to 3 suitable consecutive dilution degrees, for each of which, inoculate two aseptic flat
dishes, 1ml per dish, and at the same time, add 1ml physiological saline in the two aseptic flat dishes for
blank control.
8.2.2 Pour 15ml to 20ml violet red bile agar (VRBA) which is cooled to 46C in each of the flat dishes in
time, turn the flat dishes carefully to blend the culture medium with the sample liquor properly. After agar is
coagulated, add 3ml to 4ml VRBA to cover the plate surface. Flip the plate and put it in 360±10 for 18h to
24h.
Select plates with colony counts between 15 to 150 and count typical and doubtful coliforms appearing on
plates. Typical coliforms are in purple, 0.5mm in diameter or bigger, surrounded by red bile salt deposit
circle.
Select 10 typical and doubtful colifoms of different types on VRBA plates, transfer- inoculate them in BGLB
broth tubes respectively, and culture them in 360±10 for24h to 48h and observe bubble generation. All BGLB
broth tubes which generate gas are reported as coliform positive.
The percentage of coliform positive test tubes finally confirmed are multiplied by the coliform plate counts in
clause 8.3 and dilution multiples to get the number of coliforms per gram (or ml) sample. E.g.: For 10-4
diluted sample liquor, 100 typical and doubtful coliforms exist on VRBA plates, and 10 of them are selected
and inoculated to BGLB broth tubes, and 6 positive tubes are confirmed. According to the foregoing, it’s
determined that the number of coliforms in this sample is: 100 X 6/10 X 104/g (ml) = 6.0 X 105 CFU/g
(CFU/ml).
A.1.1 Ingredients
Dissolve the above-stated ingredients in distilled water and regulate the pH. Separately fill the solution in
test tubes having small glass backward tubes, 10ml each, and sterilize them under high pressure in 121C for
15 minutes.
A.2.1 Ingredients
Peptone 10.0g
Lactose 10.0g
Oxgall or gxbile solution 200.0ml
0.1% brilliant green water solution 13.3ml
Distilled water 1000ml
pH 7.2±0.1
Dissolve peptone and lactose in about 500ml distilled water, add in 200ml oxgall solution (dissolve 20.0g
dehydrated oxgall powder in 200ml distilled water, regulate pH 7.0 to 7.5), dilute it with distilled water to
975ml, regulate its pH to 7.4, and then add in 13.3ml 0.1% brilliant green water solution, dilute it with distilled
water to 1000ml, filter the solution, and separately fill the filtrate in test tubes having small glass backward
tubes, 10ml each. Sterilize them under high pressure in 1210 for 15 minutes.
A.3.1 Ingredients
Dissolve the foregoing ingredients in distilled water, put the solution in stillness for several minutes, blend it
fully, and regulate the pH. Boil it for 2 minutes, cool the culture medium to 450~500 pour plate. Prepare it for
immediate use no more than 3 hours later.
A.4.1 Ingredients
Stock solution: Weigh and take 34.0g monopotassium phosphate and dissolve it in 500ml distilled water.
Regulate its pH to 7.2 with about 175ml 1mol/L sodium hydrochloride solution, dilute with distilled water to
1000ml, and store it in refrigerator.
Diluted solution: Take 1.25ml stock solution, dilute it with distilled water to 1000ml, separately fill the solution
in a suitable container, and sterilize it under high pressure in 1210 for 15 minutes.
A.5.1 Ingredients
Sodium chloride 8.5g
Distilled water 1000ml
Weigh 8.5g sodium chloride, dissolve it in 1000ml distilled water, and sterilize it under high pressure in
1210 for 15 minutes.
A.6.1 Ingredients
Weigh 40g sodium hydroxide, dissolve it in 1000ml distilled water, and sterilize it under high pressure in
1210 for 15 minutes.
A.7.1 Ingredients
Take 90ml concentrated hydrochloric acid,dilute it with distilled water to 1000ml, and sterilize it under high
pressure in 1210 for 15 minutes.
See Table 1 for the most probable number (MPN) of coliforms per gram (or millimeter) test sample.
Table 1: Most probable number (MPN) of coliforms per gram (or millimeter) test sample
Number of positive MPN 95% confidence Number of positive MPN 95% confidence
tubes tubes
0.10 0.01 0.0 Lower Upper 0.10 0.01 0.00 Lower Upper
01 limit limit 1 limit limit
0 0 1 < 0.15 9.6 2 2 1 28 8.7 94
0 1 0 3.0 0.15 1 1 2 2 2 35 8.7 94
0 1 1 3.0 1.2 1 8 2 3 0 29 8.7 94
0 2 0 6.1 1.2 1 8 2 3 1 36 8 .7 94
0 3 0 6.2 3.6 3 8 3 0 0 23 4.6 94
1 0 0 9.4 0.17 1 8 3 0 1 38 8.7 110
1 0 1 3.6 1.3 1 8 3 0 2 64 17 180
1 0 2 7.2 3.6 3 8 3 1 0 43 9 180
1 1 0 11 1.3 2 0 3 1 1 75 17 200
1 1 1 7.4 3.6 3 8 3 1 2 120 37 420
1 2 0 11 3.6 4 2 3 1 3 160 40 420
1 2 1 11 4.5 4 2 3 2 0 93 18 420
1 3 0 15 4.5 4 2 3 2 1 150 37 420
2 0 0 16 1.4 3 8 3 2 2 210 40 430
2. 0 1 9.2 3.6 4 2 3 2 3 290 90 1000
2 0 2 14 4.5 4 2 3 3 0 240 42 1000
2 1 0 20 3.7 4 2 3 3 1 460 90 2000
2 1 1 15 4.5 4 2 3 3 2 1100 180 4100
2 1 2 20 8.7 9 4 3 3 3 > 1100 420
27
Note 1: This table adopts three dilution degrees [0.1g (or 0.1ml), 0.01g (or 0.01ml) and 0.001g (or
0.001ml), for which of which, three tubes are inoculated.
Note 2: If the tested amounts as shown in this table are changed to 1g (or 1ml), 0.1g (or 0.1ml) and 0.01g
(or 0.01ml), figures in this table should be decreased by 10 times accordingly; if the tested amounts are
changed to 0.01g (or 0.01ml), 0.001g (or 0.001ml) and 0.0001g (or 0.0001ml), figures in this table should be
increased by 10 times accordingly, so on and so forth.
GB 22255-2014
Compared with GB 2760—2007, the major changes in this standard are as follows:
- This standard changed the standard title into National Standard for Food Safety ----Determination of
Sucralose in Foods
- This standard added the solid-phase extraction column purification and isolation steps in test sample
preparation.
- This standard added preparation steps for samples of fermented alcoholic drinks, integrated
alcoholic drinks and protein free beverages.
1. Scope
2. Principle
By extracting sycralose from a food sample using methanol aqueous solution, removing protein and fat
contained in the extract, purifying and enriching the extract using a solid-phase extraction column,
separating the extract using a high performance liquid chromatograph and a C18 reverse-phase
chromatographic column, then analyzing the extract using an evaporative light scattering detector or a
refractive index detector, the qualitative and the quantitative analyses could be carried out based on the
retention time and peak height/peak area respectively.
Unless otherwise specified, reagents used for the determination method specified herein are all
analytical reagents, and water used is water for analytical laboratory use----Class Ⅰ
as specified in
GB/T6682.
3.1. Reagents
3.2.1 Zinc acetate solution (219g/L): mix 21.9g Zinc acetate and 3mL acetic acid and then dilute with
water to 100mL.
3.2.2 Potassium ferrocyanide solution (106 g/L): Dilute 10.6g potassium ferrocyanide with water to
100mL.
3.2.3 Methanol-water solution (75+25): Mix up 25mL methanol and 75mL water.
3.2.4 Acetonitrile-water solution (11+89): Mix up 11mL acetonitrile and 89mL water.
3.4.1 Sucralose Standard Stock Solution (10.0mg/mL): Transfer 0.25g (accurate to 0.0001g) standard
sucralose to a 25mL volumetric flask, dilute with water to volume and mix up, the concentration will be
10.0mg/mL. Shelf life of the solution stored in a lab refrigerator at 4℃is 6 months.
3.4.2 Sucralose Inter-mediate Standard Solution: Transfer 5.00 mg/mL sucralose standard stock solution
prepared in 3.4.1 to a 50mL volumetric flask, dilute with water to volume and mix up, the concentration will
be 1.0mg/mL. Shelf life of the solution stored in a lab refrigerator at 4℃is 3 months.
3.4.3 Sucralose Standard Working Solutions: Transfer 0.200mL, 0.500mL, 1.00mL, 2.00mL and 4.00mL
inter-mediate standard solution prepared in 3.4.2 to five 10mL volumetric flasks, respectively. Dilute each
with water to volume and mix up, the concentration will be 0.0200mg/mL, 0.0500mg/mL, 0.100mg/mL,
0.200mg/mL,and 0.400mg/mL respectively.
3.5. Materials
4.1 High Performance Liquid Chromatograph:equipped with a refractive index detector/evaporative light
scattering detector.
5. Analytical procedures
5.1.1.1 Transfer a piece of 1~2g(accurate to 0.001g) solid sample crushed evenly and 1~5g liquid sample
(accurate to 0.001g) to a 50mL centrifuge tube, add 5mL water, vortex on the vortex mixer for 3 min, then
add 15mL methanol, and vortex on the vortex mixer again for 30 s; after an ultrasonic extraction for 20 min,
centrifugate at 3000r/min for 10 min, then transfer the supernatant to a 50mL centrifuge tube. Add 5.0mL
methanol-water solution(75+25) into the sediment, stir up with a glass rod, vortex on the vortex mixer for 30s,
centrifugate at 3000r/min for 10 min, and do the extraction operation again, then collect and transfer all
supernatants to a 150mL separatory funnel .
Copyright @ 2015 The Sovereign Group All Rights Reserved
228
5.1.1.2 Add 30mL Hexane into the 150mL separatory funnel mentioned above, shake for 2 min, allow the
mixture to stand for 20 minutes and separate into two layers, transfer the lower layer water phase into a
50mL evaporation dish; put the evaporation dish into the water bath for evaporation by boiling until only
about 1mL liquid remained. Wash the evaporation dish with 9mL water totally in three flushing, collect and
transfer the used water for the three flushing to a 15mL centrifuge tube. After an ultra-sonic treatment of
5min, centrifugate the used flushing water at 3000r/min for 10 min.
5.1.1.3 Inject all supernatants mentioned in 5.1.1.1 into an activated solid extraction column at a flow rate
no more than 1 drop/second, add 1mL water when the supernatant level in the column reaches about 2mm,
drain the extraction column keeping the flow rate at 1 drop/second. Then elute the extraction column with
3mL methanol, collected and transfer the used methanol eluent to a 50mL evaporation dish, put the
evaporation dish into the water bath for evaporation by boiling until the used methanol eluent contained is
dried up, dilute the evaporation residue with 1.0mL acetonitrile-water solution(11+89), and filter the solution
with a 0.45μm membrance filter, the filtered solution is the prepared test sample.
Note: For jelly products, the supernatants extracted should be heated in the water bath at 50℃and pass
through the extraction column when it is still hot to avoid plugging.
5.1.2 Sauce and Sauce Pickled Products, Soy Sauce & Vinegar
Transfer a 2g evenly mixed product sample (accurate to 0.001g) to a 50mL centrifuge tube, add 1.0g neutral
alumina and 3mL water, vortex on the vortex mixer for 3min, then add 15mL methanol, and complete the
procedure specified from 5.1.1.1 “and vortex on the vortex mixer again for 30 s; after an ultrasonic extraction
for 20 min, centrifugate at 3000r/min for 10 min” to 5.1.1.3 “the filtered solution is the prepared test sample”
in order.
Transfer a 2g evenly mixed product sample (accurate to 0.001g) to a 50mL evaporation dish, put the
evaporation dish into the water bath for evaporation by boiling until the sample is dried up, dilute the
evaporation residue with 1.0mL acetonitrile-water solution(11+89), and filter the solution with a 0.45μm
membrance filter, the filtered solution is the prepared test sample.
Transfer a 2g evenly mixed product sample (accurate to 0.001g) to a 15mL centrifuge tube, add 5mL water,
vortex on the vortex mixer for 30s, centrifugate at 3000r/min for 10 min, then complete steps specified in
5.1.1.3.
Transfer a 1~5g evenly mixed product sample (accurate to 0.001g) to a 50mL centrifuge tube, add 5mL
water, vortex on the vortex mixer for 3min, add 15mL methanol, 0.50 mL zinc acetate solution, and 0.50 mL
potassium ferrocyanide solution, centrifugate at 3000r/min for 10 min, and complete the procedure specified
from 5.1.1.1 “and vortex on the vortex mixer again for 30 s; after an ultrasonic extraction for 20 min,
centrifugate at 3000r/min for 10 min” to 5.1.1.3 “the filtered solution is the prepared test sample” in order.
For various test samples, sample pre-treatment shall be done simultaneously with a blank test.
Note: In order to avoid influences of strong retention substances on subsequent testing steps, an elution
procedure (applicable to evaporative light scattering detectors) could be to adopt after testing a sample with
complex matrix.
----Detection Sensitivity: 16
The detector should be set according to its brand-specific requirements for high water mobile phase.
For example, a Sedex 75 evaporative light scattering detector should be set as follows:
Inject 20.0μL of the 5 kinds of sucralose standard working solutions, respectively. Determine the peak area
under the chromatographic conditions mentioned above, and establish the peak
area-sucralose concentration (mg/mL) standard curve. As shown in Formula (1), the curve equation
complies with working principles of the refractive index detector.
In the formula:
a, b----constants related to detection cell temperature, mobile phase properties and other experimental
conditions
Inject 20.0μL of the 5 kinds of sucralose standard working solutions, respectively. Determine the peak area
under the given chromatographic conditions, and establish the peak area-sucralose concentration
(mg/mL) standard curve. As shown in Formula (2), the curve equation complies with working principles of
the evaporative light-scattering detector.
In the formula:
a, b----constants related to evaporation chamber temperature, mobile phase properties and other
experimental conditions
Depending on the data processing method of software processing data collected by experimental
instruments, the above mentioned Equation may be converted into a logarithmic equation, i.e. lgy=b+algx.
Inject 20.0μL sample solution and 20.0μL blank solution into a high performance liquid chromatograph ,
respectively and carry out high-performance liquid chromatographic evaluations. As specified in Annex B,
the qualitative and the quantitative analyses shall be carried out based on the retention time and the peak
area external reference method, respectively.
In the formula:
c----refers to the sucralose concentration positioned on the standard curve, in the liquid injected as sample,
(mg/mL)
c0----refers to the sucralose concentration positioned on the standard curve, in the liquid injected as blank
sample, (mg/mL)
7. Precision
The absolute difference between two independent determination results obtained based on the repeatability
of the determination procedure should not exceed 10% of these tow results’ mathematic average.
8. Others
If dilute a sample of 2g with water to 1.00 mL, the detection limit is 0.0025 g/kg, and the quantitation limit is
0.0075 g/kg.
In order to avoid influences of strong retention substances on subsequent testing steps, an elution
procedure could be to adopt after testing a sample with complex matrix. Elution parameters are as shown in
Table A.1.
Table A.1 Elution Procedure of the Liquid Chromatograph under Complex Conditions (applicable to
evaporative light scattering detectors)
Fig B.1 Liquid Chromatogram(evaporative light scattering detector) of Standard Sucralose Solution
Refer to Fig B.2 for liquid chromatogram (refractive index detector) of standard sucralose solution
(0.200mL).
Fig B.2 Liquid Chromatogram (refractive index detector) of Standard Sucralose Solution
Foods
GB 14880-2012
This standard referred to the standards of Codex Alimentarius Commission (CAC) ‘Codex Stan CAC/GL
09-1987 (amended 1989,1991) General Principles for the addition of Essential Nutrients to Foods’ and
CAC/GL 10-1979 (revised 2008) Advisory Lists of Nutrient Compounds for Use in Foods for Special
Dietary Uses for Infants and Young Children. This standard also referred to the regulation of European
Union ‘No. 1925/2006 Regulation on the Addition of Vitamins and Minerals and of certain other
substances to foods’.
This standard replaced the previous version: the standard GB 14880-1994 < Hygiene Standard for the use
of nutritional fortification substances in foods>
Compared to the standard GB 14880-1994, this standard has some changes as follows:
- The principles of nutritional fortification, the principles of using nutritional fortification substances and
the principles of selecting carriers for nutritional fortification substances are added.
- Based on the risk assessment, the food classification system is combined into this standard. The
application of varieties, scope and amount of nutritional fortification substances are adjusted and
integrated. Some food categories, which are not suitable for nutritional fortification, are deleted.
- The sources of nutritional fortification substances for food for special dietary uses are increased and
the application amounts of some of the nutrients are increased
- The Appendix A ‘Rules for implementation of health standards for nutritional fortification substances
is deleted. (The Appendix A, Appendix B and Appendix C are standardized appendices. Appendix D
is information Appendix)>
- GB 14880-1994
1. Scope
This Standard stipulates the principles for the fortification of nutritional fortification substances in food, the
principles for the use of nutritional fortification substances and the principles for selecting carrier of
nutritional fortification substances. This standard also stipulates the application of varieties, scope and
amount of the nutritional fortification substances.
Nutritional fortification substances are natural, synthetic nutrients and other nutritional components, which
are added into food to increase the nutritional value of food.
2.2. Nutrients
A nutrient is a substance that an organism needs to live, grow, develop, reproduce and metabolize. It has
special physiological functions. Nutrients include proteins and amino acids, fats and fatty acids,
carbohydrates, minerals, vitamins, and etc.
Nutritional components are food ingredients, which have nutritional and physiological functions.
Fortified foods are those foodstuffs in which a certain amount of nutritional fortification substances are
added.
These foods must supply a special dietary need that exists by reason of a physical or physiological condition
or by reason of a specific disease or disorder. The ingredients of these foods should be significantly different
from those of conventional or natural foods.
3.2. Nutritional fortification substances can be used to compensate the nutrient loss during food processing
or storage.
3.4. There is sufficient evidence to show that in certain geographic areas, the low intake of certain/some
nutrients or nutrient deficiencies are caused by dietary habits or other factors; and the low intake level of the
nutrients and adverse health effects caused by the nutrient deficiency can be improve by nutritional
fortification and the nutrients can be provided to the people with nutrient deficiency through fortified foods.
3.6. Supplement and modify the nutrients and the content of other nutritional substances in food for special
dietary uses.
4.1. The use of nutritional fortification substances should comply with the following principles:
4.2. The use of nutritional fortification substances must not lead to excessive intake of the nutrients or/and
nutrient imbalance; and must not lead to metabolic disorders.
4.3. Nutritional fortification substances should remain stable (in terms of quality) in foods during storage,
transport, and consumption.
4.4. Additional of nutritional fortification substances must not lead to undesirable changes of foods in terms
of colors, taste, flavor, cooking property etc.
4.5. The use of nutritional fortification substances should not cause misleading information and
misconception to consumers through exaggerating the content of a certain nutritional ingredient.
4.6. The use of nutritional fortification substances should not encourage or lead to food consumption models
that are contrary to the country’s nutrition regulations.
5.1. The selection of carriers for nutritional fortification substances should comply with the following
principles:
5.2. Should select foods that are easy to purchase and obtain by the target population.
5.3. The consumption of food carriers should be stable, thus to help calculate the additive amount of
nutritional fortification substances, and should be able to avoid excessive levels of nutrients and other
nutritional substances in the human body due to excessive intake of the food carriers.
5.4. The natural foods, which are already good source of a certain nutrients, should not be used as carriers
of this nutrient.
6.1. The application scope, application amount of nutritional fortification substances should comply with the
requirement of Appendix A, the sources of chemicals should comply with the regulation of Appendix B;
6.2. The contents of nutrients and other nutritional substances used in foods for special dietary uses should
comply with the National Food Safety Regulation, the allowed sources of nutritional fortification substances
should comply with the requirement of Appendix C.
The food class system is used to define the application scope of nutritional fortification substances. It is
only applicable for this standard, please refer to Appendix D If a certain nutritional fortification substances
is allowed to use in a certain food category, then this substances can be used in all foodstuffs under this
category, except otherwise provided.
The uses of nutritional fortification substances should comply with the standard of quality specification and
corresponding regulations.
C.1: List of source of nutritional fortification substances for food for special dietary uses
Nutrients The source of nutritional compounds
Retinol acetate (Vitamin A acetate)
Retinol palmitate (Vitamin A palmitate)
Vitamin A
Β-carotene
All-trans-retinol
Ergocalciferol (Vitamin D2)
Vitamin D
Cholecalciferol (Vitamin D3)
d-α tocopherol
dl-α tocopherol
dl-α tocopheryl acetate
Vitamin E
dl-α tocopheryl acetate
Mixed tocopherol concentrate
d-α-tocopherol succinate
Vitamin K Phytonadione
Thiamine hydrochloride
Vitamin B1
Thiamine mononitrate
Riboflavin
Vitamin B2
Riboflavin-5'-phosphate
Pyridoxine phosphate
Vitamin B6
5-pyridoxine phosphate
Cyanocobalamine
Vitamin B12
Cyanocobalamine hydrochloride
L-ascorbic acid
Sodium L-ascorbate
Vitamin C
Calcium L-ascorbate
L-ascorbic acid, potassium ascorbate -6 – palmitate (ascorbyl palmitate)
Niacin
Niacin
Nicotinamide
Folic acid Folic acid
D-calcium pantothenate
Pantothenic acid
D-sodium pantothenate
Biotin D-biotin
Choline chloride
Choline
Choline bitartrate
Inositol Inositol
Sodium bicarbonate
Sodium dihydrogen phosphate
Sodium
Sodium citrate
Sodium
GB 22570-2014
This standard supersedes GB/T 22570-2008 Complementary Food Supplement National Standard
Compared with GB/T 22570-2008, the following changes have been made to the Standard:
1. Scope
This Standard applies to complementary food supplement for infants from 6 months to 36 months, and
children from 37 months to 60 months.
Food supplement refers to additional foods to meet nutritional needs for more than 6-month-old infants and
young children who are continuing to breast feed. The foods come by both family prepared and factory
production
A kind of supplements full of micronutrients (vitamins and minerals), with or without the food matrix and other
complementary food, add in the instant food supplement for infants from 6 months to 36 month old, and
young children from 37 months to 60 months old as well. Now the common types are: complementary feed
nutrient supplements, complementary micronutrient supplements and complementary micronutrients
reagents.
Food matrix based on one or more of soybean, soy protein, milk and milk protein products, made from
complementary feed nutrient supplements by adding micronutrients and (or) other supplements. Food
shape can be powder, granular or semi-solid, and the food matrix could provide part of high quality protein.
Food matrix based on one or more of soybean, soy protein, milk and milk protein products, made from flake
complementary food supplements by adding micronutrients and (or) other supplements. The supplements
are breakable or easily dispersed.
3. Technical Requirements
Complementary feed nutrient supplements are of 10.0g ~ 20.0g, complementary micronutrient supplement
tablets are of 1.5g ~ 3.0g, and complementary micronutrients sprinkles are of 0.8g ~ 2.0g
3.2.1 Food matrix shall be take instant edible food as raw materials, and its quality shall meet the relevant
standards and (or) regulations
3.2.2 Soybean and soybean-based products shall be under the process of high-temperature treatment to
eliminate the anti-nutritional factors such as trypsin inhibitors, etc.
3.2.3 Food accessories shall meet the relevant standards and (or) regulations
The color, taste, smell and organization status of complementary food supplements shall conform to the
relevant product specifications, and shall be no visible extraneous matter
In complementary foods supplement, protein content shall be no less than 25g/100g, test method shall
followed by GB 5009.5, and protein content calculation shall be Nitrogen (N) * 6.25
Other nutrients content in complementary food supplement shall convert into daily content and be consistent
with the requirements of Table 1
In addition to the essential components in 3.4, if one or more nutrients listed in Table 2 can be selected to
add or claimed on label, whereas the content of such nutrients converted in to daily content shall meet the
specification of Table 2
3.9.2 The use of nutrition fortifiers shall conform to GB 14880 requirements, among which the ethyl diamine
tetra sodium acid daily dosage in terms of iron shall not exceed 2.8mg
3.9.3 Quality of food additives and nutrition fortifiers shall be consistent with relevant safety standards and
requirements
The urease activity of products containing soy component shall be consistent with the provisions of Table 6
4. Labels
4.1 Product labels shall comply with the provisions of GB 13432, and mark ‘food supplements’ and (or) the
corresponding category of ‘complementary feed nutrient supplements’, ‘complementary micronutrient
supplement tablets’ and ‘Complementary micronutrients supplement sprinkles’
4.2 Label shall be identified by the different month, and mark ‘this product add micronutrients, please pay
attention to eat with other similar products’. If the products face to the infants from 6 ~ 36-month-old, the
label shall be marked ‘this product is not a substitute for breast milk and infant food aid’
Purposes
GB 29922-2013
1. Scope
This standard is applicable to formulated foods for special medical purposes which are suitable for people
above 1 year.
As especially formulated foods that are produced to meet the special requirements for nutrient or meals of
people who suffer from eating limitation, disorder of digestion and absorption, metabolic disorders or special
disease state, these products shall be eaten individually or with other foods under the guidance of doctors or
clinical dietitians.
Formulated foods for special medical purposes that can meet the requirements of target groups for nutrition
as a single nutrition source.
Formulated foods for special medical purposes that can meet the requirements of target groups for nutrition
under the condition of specified diseases or medical conditions as a single nutrition source.
Formulated foods for special medical purposes that can meet the requirements of target groups for nutrition
and are not suitable to be used as a single nutrition source.
3 Technical requirements
Formulated foods for special medical purposes shall be based on the medical and/or nutritional research
results with scientifically verified security and clinical effects. Their production condition shall also be in
accordance with relevant national regulations.
Formulated foods for special medical purposes shall be made of raw materials which meet the requirements
of relevant standards and/or regulations. Those which jeopardize consumers’ health shall be forbidden.
The colors, tastes, smells, textures and dissolving ability of formulated foods for special medical purposes
shall be in accordance with their characteristics and include no visible extraneous matters.
3.4.1.1 Full nutritional formula foods suitable for people aged from 1 to 10 years shall contain 250 kJ (60
kcal) of energy or more in every 100 mL of their liquid products or reconstituted foods under their
immediately-edible condition,or in every 100 g of their immediately edible non-liquid products. To calculate
the energy, we can multiply the content of protein, fat and carbohydrate in every 100 mL or 100 g of products
by their respective energy coefficients, i.e. 17 kJ/g, 37 kJ/g and 17 kJ/g(energy coefficients of dietary fiber,
to be calculated with 50% of carbohydrate energy coefficient). Their sums are the values of kJ/100mL or
kJ/100g , which can be divided by 4.184 to be the values of kcal/100mL or kcal/100g.
3.4.1.2 Full nutritional formula foods suitable for people aged from 1 to 10 years shall contain 0.5g/100kJ
(2g/100kcal) of protein or more, in which quality protein shall account for 50% or more.Please see GB
5009.5 for the way to test protein.
3.4.1.3 In the full nutritional formula foods suitable for people aged from 1 to 10 years, the energy supply
ratio of linoleic acid shall be 2.5% or more and that of -linolenic acid shall be 0.4% or more.Please see GB
5413.27 for the way to test aliphatic acid.
3.4.1.4 In the full nutritional formula foods suitable for people aged from 1 to 10 years, the content of
vitamins and mineral substances shall be in accordance with Table 1.
3.4.1.5 Except for the ingredients specified in Table 1, if one or more ingredients in Table 2 are added or
shown in the products, their content shall be in accordance with Table 2.
Table 1 Vitamin and mineral substance index (people aged from 1 to 10 years)
Every 100kJ Every 100kca
Nutrient Test method
Minimum Maximum Minimum Maximum
Vitamin A/(µg GB 5413.9 or GB/T
17.9 53.8 75 225
RE) a 5009.82
b
Vitamin D/(µg) 0.25 0.75 1.05 3.14 GB 5413.9
Vitamin E/(mg GB 5413.9 or GB/T
0.15 N.Se 0.63 N.S.
α-TE) c
5009.82
GB 5413.10 or GB/T
Vitamin K1 /(µg) 1 N.S. 4 N.S.
5009.158
GB 5413.11 or GB/T
Vitamin B1/(mg) 0.01 N.S. 0.05 N.S.
5009.84
Vitamin B2/(mg) 0.01 N.S. 0.05 N.S. GB 5413.12
GB 5413.13 or GB/T
Vitamin B6 /(mg) 0.01 N.S. 0.05 N.S.
5009.154
3.4.2 Full nutritional formula foods suitable for people aged above 10 years
3.4.2.1 Full nutritional formula foods suitable for people aged above 10 years shall contain 295 kJ (70 kcal)
of energy or more in every 100 mL of their liquid products or reconstituted foods under their
immediately-edible condition, or in every 100 g of their immediately edible non-liquid products. To calculate
the energy, we can multiply the content of protein, fat and carbohydrate in every 100 mL or 100 g of products
by their respective energy coefficients, i.e. 17 kJ/g, 37 kJ/g and 17 kJ/g(energy coefficients of dietary fiber,
to be calculated with 50% of carbohydrate energy coefficient). Their sums are the values of kJ/100mL or
kJ/100g , which can be divided by 4.184 to be the values of kcal/100mL or kcal/100g.
3.4.2.2 Full nutritional formula foods suitable for people aged from 1 to 10 years shall contain 0.7g/100kJ
(3g/100kcal) of protein or more, in which quality protein shall account for 50% or more. Please see GB
5009.5 for the way to test protein.
3.4.2.3 In the full nutritional formula foods suitable for people aged above 10 years, the energy supply ratio
of linoleic acid shall be 2.0% or more and that of-linolenic acid shall be 0.5% or more. Please see GB
5413.27 for the way to test aliphatic acid.
3.4.2.4 In the full nutritional formula foods suitable for people aged above 10 years, the content of vitamins
and mineral substances shall be in accordance with Table 3.
Copyright @ 2015 The Sovereign Group All Rights Reserved
270
3.4.2.5 Except for the ingredients specified in Table 3, if one or more ingredients in Table 4 are added or
shown in the products, their content shall be in accordance with Table 4.
Table 3 Vitamin and mineral substance index (people aged above 10 years)
The energy and nutrient content of specific full nutritional formula foods shall be based on the full nutritional
formula foods in 3.4.1 or 3.4.2, but can be properly adjusted according to the special requirements of
diseases or medical condition for nutrients to meet the nutrition requirements of target groups. Please see
the common specific full nutritional formula foods in Appendix A.
The common none-full-nutritional formula foods include nutrient ingredients, electrolyte formula, thickening
ingredients,liquid formula and formula of amino acid metabolism disorder. Technical indicators of all
products shall be in accordance with the requirements of Table 5. Unable to satisfy the nutrition
requirements of target groups as a single nutrition source, such products shall be consumed with other
foods. So their nutrient content shall not be required. None-full-nutritional formula foods shall be consumed
in accordance with the special condition or requirements of individual patients under the guidance of doctors
or clinical dietitians.
a
means content of single amino acids
Limited quantity of microorganism in solid formulated foods for special medical purposes shall be in
accordance with Table 9. Microbiological indicators for liquid formulated foods for special medical purposes
shall be in accordance with commercial standard of sterility and be tested according to GB/T 4789.26.
(demonstrated
Sampling plana quantity limit
Items with CFU/g if not being specified) Test method
n c m M
Aerobic bacterial
5 2 1000 10000 GB 4789.2
count b ,c
GB4789.3
Coliform 5 2 10 100
plate counting method
Salmonella 5 0 0/25g - GB 4789.4
Staphylococcus GB 4789.10
5 2 10 100
aureus plate counting method
a
Samples shall be analyzed and processed in accordance with GB 4789.1.
b
Products which are not suitable to include active bacteria (aerobiotic and anaerobic probiotics)
(viable count of activated probiotics in products shall be 106 CFU/g ( mL ) or more)
c
Products only suitable for people aged from 1 to 10 years.
3.8.1 The usage of food additives in products suitable for people aged from 1 to 10 years shall be in
accordance with additive types and usage for infant formula foods in GB 2760. The usage of food additives
in products suitable for people aged above 10 shall be in accordance with additive types and usage for the
same or similar products in GB 2760.
3.8.4 One or more amino acids can be added to the formulated foods for special medical purposes
according to people’s special requirement for nutrition. The origin of amino acids shall be in accordance with
Appendix B and/or GB 14880.
3.8.5 Other substances that are added to formulated foods for special medical purposes shall be in
accordance with the relevant national regulations.
4 Others
4.1 Labels
4.1.1 Product labels shall be in accordance with GB 13432. The label“ every 100 kJ (/100kJ)”shall be
added to the label of nutrient and selectable ingredients.
4.1.2 The formula or nutritional features of products shall be described in the label, as well as the product
types,target users and the warning“ unsuitable for non-target people”.
4.1.3 The warning “to be used under the guidance of doctors or clinical dietitians” shall be placed in the
striking area of the label.
4.1.4 The warning “this product shall not be used for parenteral nutrition support or intravenous
injection”shall be shown in the label.
4.2.1 The usage, explanation and diagram of formulation, and the storage condition of relevant products
shall be definitely specified on the label. Such a diagram may not be used when the largest superficial area
of the package is less than 100 cm2 or the product weight is less than 100 g.
4.2.2 Hazard to health due to improper formulation or misuse shall be demonstrated in the instructions.
4.3 Packages
Food-grade carbon dioxide and/or nitrogen whose purity is 99.9% or more can be used as the packing
medium.
A.6 Full nutritional formula foods for the muscle attenuation syndrome
A.7 Full nutritional formula foods for trauma, infection, surgery and other stress situations
A.9 Full nutritional formula foods for food protein allergy related
A.11 Full nutritional formula foods for gastrointestinal malabsorption and pancreatitis
A.12 Full nutritional formula foods for fatty acid metabolism disorder
A.13 Full nutritional formula foods for obesity and defatting surgery
medical purposes
See the amino acids that can be used in formulated foods for special medical purposes at Table B.1.
Table B.1 Amino acids that can be used for formulated foods in special medical purposes
Arse
Moist Ash Lea
Puri
S/R nic
Specific ty ure % d
Amino Compound Molecular Molecula
Num Chemical name
a,b
source formula r weight
rotation pH % ≤ mg/ mg/k
acid %
ber [α]D,20℃ kg g
≤
≥
≤ ≤
Aspartic L-aspartic acid L-Asparaginic acid C4H7NO4 133.1 +24.5~+26.0 2.5~3 98.5 0.2 0.1 0.3 0.2
1
acid L-magnesium L-magnesium aspartic 2(C4H6NO4) Mg 288.49 +20.5~+23.0 - 98.5 0.2 0.1 0.3 0.2
2 Threoni L-threonine L-2-amino-3-hydroxyb C4H9NO3 119.12 -26.5~-29.0 5.0~6 98.5 0.2 0.1 0.3 0.2
3 Serine L-serine L-2-amino-3-hydracryli C3H7NO3 105.09 +13.6~+16.0 5.5~6 98.5 0.2 0.1 0.3 0.2
L-glutamic acid α-aminoglutaric acid C5H9NO4 147.13 +31.5~+32.5 3.2 98.5 0.2 0.1 0.3 0.2
Glutami
4 L-potassium α-potassium C5H8KNO4·H2O 203.24 +22.5~+24.0 - 98.5 0.2 0.1 0.3 0.2
c acid
L-calcium α-calcium C10H16CaN2O8 · 404.39 +27.4~+29.2 6.6 98.5 0.2 0.1 0.3 0.2
5 Glutami L-glutamine 2-amino-4-butanoic C5H10N2O3 146.15 +6.3~+7.3 - 98.5 0.2 0.1 0.3 0.2
6 Proline L-proline Pyrrolidine-2-carboxyli C5H9NO2 115.13 -84.0~-86.3 5.9~6 98.5 0.2 0.1 0.3 0.2
7 Glycine Glycine Amino acetic acid C2H5NO2 75.07 - 5.6~6 98.5 0.2 0.1 0.3 0.2
8 Alanine L-alanine L-2-aminopropionic C3H7NO2 89.09 +13.5~+15.5 5.5~7 98.5 0.2 0.1 0.3 0.2
L-cystine L-3,3'-dithiobis C6H12N2O4S2 240.3 -215~-225 5.0~6 98.5 0.2 0.1 0.3 0.2
( 2-aminopropionic .5
L-cysteine L-α-amino-β-thiohydra C3H7NO2S 121.16 +8.3~+9.5 4.5~5 98.5 0.2 0.1 0.3 0.2
9 Cystine L-cysteine L-cysteinyl C3H7NO2S·HCl·H 175.63 +5.0~+8.0 - 98.5 0.2 b 0.1 0.3 0.2
N-acetyl-L-cyst N-acetyl-L-α-amino-β-t C5H9NO3S 163.20 +21~+27 2.0~2 98.0 0.2 0.1 - -
eine hiohydracrylic acid .8
10 Valine L-valine L-2-amino-3-isovaline C5H11NO2 117.15 +26.7~+29.0 5.5~7 98.5 0.2 0.1 0.3 0.2
Methion L-methionine 2-amino-4-methyl C5H11NO2S 149.21 +21.0~+25.0 5.6~6 98.5 0.2 0.1 0.3 0.2
11
ine N-acetyl-L-met N-acetyl-2-amino-4-m C7H13NO3S 191.25 -18.0~ -22.0 - 98.5 0.2 0.1 0.3 0.2
12 Leucine L-leucine L-2-amino-4-methyl C6H13NO2 131.17 +14.5 ~+16.5 5.5~6 98.5 0.2 0.1 0.3 0.2
Arsen
Moist
Specific Purity Ash Lead ic
S/R Amino Compound Molecular Molecular ure
Chemical name rotation pH % % mg/kg mg/k
Number acid a,b source formula weight %
[α]D,20℃ ≥ ≤ ≤ g
≤
≤
L-2,6-diamino caproic
L-lysine-aspart C10H21N3O +24.0 ~ 5.0~7.
acid L- amino 279.30 98.0 0.2 0.1 0.3 0.2
ic acid 6 +26.5 0
succinate
L-2-amino-5-guanidyl
L-arginine C6H14N4O2 +21.3~+
valeric acid 210.66 - 98.5 0.2 0.1 0.3 0.2
hydrochloride ·HCl 23.5
17 Arginine hydrochloride
L L-2-amino-5-guanidyl
C10H21N5O +25.0 ~ 6.0~
-arginine-aspa valeric acid- L-aspartic 307.31 98.5 0.2 0.1 0.3 0.2
6 +27.0 7.0
rtic acid acid
Purposes
GB 29923-2013
1. Scope
The standard specifies the basic requirements and administration rules for the sites, facilities and personnel
during the raw material purchase, processing, packaging, storage and transportation of formulated foods for
special medical purposes.
The standard is applicable to manufacturers of formulated foods for special medical purposes including
infant formula foods for special medical purposes.
The following terms and definitions specified in GB 14881--National Standard for Food Safety, General
Hygienic Regulation of Food Production are applicable to the standard.
As especially formulated foods that are produced to meet the special requirements for nutrient or meals of
people who suffer from eating limitation, disorder of digestion and absorption, metabolic disorders or special
disease state , these products shall be eaten individually or together with other foods under the guidance of
doctors or clinical dietitians. Formulated foods for special medical purposes shall be based on the medical
and/or nutritional research results with scientifically verified security and clinical effects.
Work areas with high requirements for cleanliness, such as the processes where liquid products are in
contact with the air environment (such as the weighing and compounding), bottling rooms and workshops for
storage, filling and inner packing of semi-finished products where powder products are exposed for
packaging.
Work areas with requirements for cleanliness lower than clean work area, such as the raw material
pre-treatment plants.
Work areas with lower requirements for cleanliness than sub-cleaning work area, such as milk collection
rooms, warehouses for raw materials and packaging materials, workshops for external packing and
warehouses for finished products, etc.
A condition where products, after proper sterilization, contain neither pathogenic microorganisms nor
non-pathogenic microorganisms that can breed in the normal temperature.
4.1.2 Facilities and equipment related to manufacture shall be properly designed, built and planned at the
workshop and factory so as to prevent the breeding and pollution of microorganisms, especially the pollution
of salmonella. As to infant products, pollution of enterobacter sakazakii (belonging to Cronobacter) shall be
especially prevented. Their hideouts or breeding shall be prevented or reduced as much as possible. The
following shall be considered during the design:
a) Dry area shall be separated from wet area. Cross contamination due to personnel, equipment and
material flow shall be effectively controlled.
b) Work material shall be properly piled to prevent the sites from being untidy due to
improper piling.
c) The enclosure and sealing between the perforations and various pipes cables which go through the
building floors, ceilings and walls shall be ensured.
d) The wet cleaning procedure shall be properly designed to prevent the breeding and spreading of
microorganisms in dry areas due to improper wet cleaning procedures.
e) Proper facilities or measures shall be utilized or taken to remain dry while avoiding and timely removing
water residue, thus preventing relevant microorganisms from growing and spreading.
4.1.3 Cleanliness levels for work zones shall be determined according to the requirements for
manufacturing techniques, sanitation and quality. In principle, work zones can be divided into ordinary zones,
sub-clean zones and clean zones.
4.1.4 Work without follow-up sterilization in dry processing areas shall be done in clean work areas, such
as the work from drying (or post-drying) processes to the filling and sealing of packages.
4.1.5 Work zones of different cleanliness levels shall be effectively separated. Independent air cleaning
systems with filters shall be installed at the clean work zones. Furthermore, positive pressure in the areas
shall be maintained so as to prevent the air that is not purified from going into the clean work areas and
causing cross contamination.
4.1.6 There shall be proper limitation and control over the behaviors of entering and exiting the clean
work areas so as to avoid or reduce microorganism pollution. There shall be relevant measures to prevent
cross contamination due to the personnel, raw materials, packaging materials, waste and equipment that
enter or exist the clean work area, such as the work clothes, shoes or shoe covers replaced in the changing
rooms, special logistics channels and waste channels. Proper air filtration systems shall be designed and
installed for powder materials or products which enter the clean work zones via pipelines.
Copyright @ 2015 The Sovereign Group All Rights Reserved
283
4.1.7 The purification levels in every work zone shall meet the requirements of formulated foods for
special medical purposes for air purification when being processed. The air cleanliness in clean work zones
and sub-clean work zones for solid and liquid products shall be in accordance with Table 1 and Table 2, and
be inspected on a regular basis.
Table 1 Requirements for control over the air cleanliness in clean and sub-clean work areas for solid
products
Requirements
Items Sub-clean Clean work Test method
work areas areas
≥0.5μm — ≤7,000,000 To be tested in accordance with
Dust ≥5μm ≤60,000 GB/T 16292. The test state is
—
count/m3 static state.
Ventilation rate a(per hour) — 10~15 —
Total bacterial count(CFU/皿) ≤30 ≤15 To be tested with the natural
sinking method in accordance
with GB/T 18204.1.
a Ventilation rate is applicable to clean work zones with floors lower than 4.0m.
Table 2 Requirements for control over the air cleanliness in clean work areas for liquid products
Requirements
Items Clean work areas Test method
≥0.5μm ≤3,500,000 To be tested in accordance with
Dust
≥5μm ≤20,000 GB/T 16292. The test state is
count/m3 static state.
a
Ventilation rate (per hour) 10~15 —
To be tested with the natural
Total bacterial count(CFU/皿) ≤10 sinking method in accordance
with GB/T 18204.1.
aVentilation rate is applicable to clean work zones with floors lower than 4.0m.
4.1.8 Clean work areas shall be dry. Water facilities and systems shall be prevented as much as possible
there. If unable to avoid them, they shall not pass through the upper space of the production work area in
case secondary pollution occurs. There shall also be preventive measures.
4.1.9 There shall be facilities to keep animals such as insects and rats away from plants, workshops and
warehouses.
4.2.1 Ceilings
4.2.1.2 Internal ceilings and top corners in work sites such as workshops shall be easy to clean so as to
avoid dust accumulation, dew formation, mold growth or exfoliation and other conditions. Smooth and
cleanable ceilings shall be added where, in clean work zones, sub-clean work zones and other sites
where foods are exposed, ceilings are apt to harbor dusts. Ceilings made of reinforced concrete shall be
flat and gap-free.
Copyright @ 2015 The Sovereign Group All Rights Reserved
284
4.2.1.3 Flat-topped ceilings in workshops shall be made of white or light-colored, non-toxic, odorless
waterproof materials. Mold-proof, durable and cleanable coating shall be used when necessary.
4.2.2 Walls
They shall be in accordance with GB 14881. Self-closing doors (with auto sensors or door closers) and/or air
curtains shall be installed at the entrances and exits of clean work zones and sub-clean work zones.
4.2.4 Grounds
They shall be in accordance with GB 14881. Grounds, where drainage or waste water flows and which are
often damp or washed with water during work, shall be acid- and alkali- resistant and slope at some angle for
drainage.
4.3 Facilities
4.3.1.2 Water facilities and equipment shall be in accordance with relevant national administrative
regulations.
4.3.1.3 Safety and health facilities shall be installed at the entrances of water facilities so as to prevent
animals and other substances from entering and causing food pollution.
4.3.1.4 Secondary water supply facilities shall be in accordance with GB 17051-- Hygienic Regulations for
Secondary Water Supply Facilities.
4.3.2.2 The drainage system shall slope at some angle and keep unobstructed so as to be cleaned and
maintained. There shall be some curve at the junction of flanks and bottoms of the drainage ditches.
4.3.2.3 There shall not be water supply pipes for production water within the drainage systems and
underneath.
4.3.4.2 Secondary dressing rooms shall be installed at the entrances of clean work areas. Hand
disinfection facilities shall be installed at the entrances of clean work areas.
Copyright @ 2015 The Sovereign Group All Rights Reserved
285
4.3.5 Ventilation equipment
4.3.5.1 They shall be in accordance with GB 14881. Environment temperature and, when necessary, air
humidity shall be controlled at clean work areas where powder products are manufactured.
4.3.5.2 Air conditioning facilities shall be installed at the clean work areas so as to avoid devaporation and
keep the indoor air fresh. Proper facilities for removal, collection or control shall be installed at the areas
where odors, gas (steam, poisonous and hazardous gas) or powder may contaminate foods.
4.3.5.3 The air inlet shall be 2m above the ground or roof. It shall be away from the pollution sources and
air outlets. Air filtering facilities shall be installed.
4.3.5.4 Compressed air or other inert gases that are used to transport or package foods, clean the food
contact surfaces or facilities shall be filtered and purified.
It shall be in accordance with GB 14881. The workshop daylight factor shall reach Standard Ⅳor higher.
Mixing illumination in the quality control working plane shall reach 540 lx or higher. And the working plane in
the processing sites shall reach 220 lx or higher and that in other sites shall reach 110 lx or higher.
Beam-focusing sensitivity test zones are exceptions.
4.3.7.2 Storage sites shall be divided according to the different characteristics of raw materials,
semi-finished products, finished products and packing materials. Refrigerating (freezing) chambers shall be
used when necessary. Different substances shall be properly separated or divided (classified or stored in
different shelves or zones) and obviously marked when stored in the same warehouse.
5. Facilities
5.1.1.2 Operation specifications of special equipment (such as pressure vessels and pressure pipes) shall
be formulated during the productive process.
5.1.2 Materials
5.1.3 Design
5.1.3.3 The facilities that are in contact with ingredients shall have smooth, complete, anti-corrosion,
dead-zone-free interiors that are easy to clean. These interiors shall be made of materials that neither react
with ingredients nor release particles nor absorb ingredients.
5.1.3.4 Storage, transportation and processing systems (including gravity, pneumatic, airtight and
automatic systems) shall be designed and manufactured to facilitate the maintenance of their good sanitary
conditions.
5.1.3.5 There shall be special zones for the storage of spare parts so as to provide necessary parts for
equipment maintenance. Storage zones for spare parts shall be kept clean and dry.
5.1.3.6 Production equipment shall bear obvious labels for running status and be kept, maintained and
verified on a regular basis. The product quality shall not be impaired during their installation and
maintenance. Facilities shall be verified or determined to ensure that all their performance meets the
requirements of the technology. Disqualified facilities shall be removed away from the production area. They
shall have obvious labels before being removed.
5.1.3.7 Measuring instruments and key gauges for production shall be examined on a regular basis.
Facilities for dry blending can ensure the mixing uniformity of products.
5.2.2 See the related functions of computer systems and their network techniques in Appendix A when
carrying out collection of key control points monitoring data and managing various records with these
computer systems and their network techniques.
5.3.2 Every time before production, facilities shall be checked to find if they are under normal conditions
so as to ensure that the hygienic quality of products is not impaired. Failures shall be timely eliminated once
they occur. Time and causes of failures, as well as the product groups that may be affected, shall be
recorded.
6.2.2 Removable devices and tools which have been cleaned and sterilized shall be placed in a proper
site where food contact surfaces will not be contaminated again so as to keep them applicable.
6.3.1 Effective plans and procedures for cleaning and sterilization shall be formulated to ensure the
sanitation and hygiene of food processing sites, equipment and facilities and to avoid food contamination.
6.3.2 In clean work zones where dry operation is needed (such as dry blend, powder product filling, etc),
to perform the effective dry-clean process on the production equipment and processing environments is an
effective way to prevent microorganisms from breeding. Wet-clean processes shall be avoided as much as
possible. Wet-clean processes shall be limited to equipment components that can be carried to special
rooms or conditions where dry-clean processes are not available. When dry-clean processes are not
available, wet-clean processes under control shall be performed only if equipment and environments can be
timely, thoroughly recovered to dryness in case the zone is contaminated.
6.3.3 Effective supervisory processes shall be formulated so as to ensure that key processes (such as
manual cleaning, cleaning in place and facility maintenance) are in accordance with relevant regulations and
standard requirements. In particular, applicability of cleaning and disinfection solutions shall be ensured.
Concentration of disinfectants and detergents shall be appropriate. CIP System shall meet the relevant
requirements for temperature and time and the equipment shall be properly rinsed when necessary.
6.3.4 The periodic chart to clean and sterilize all the workshops shall be formulated so as to ensure all the
zones are cleaned and special cleaning are carried out on important zones, equipment and tools. The cycle
and effectiveness to clean the equipment shall be verified or justified.
6.3.5 The amount of cleaning staff shall be guaranteed and their individual responsibilities shall be
specified. All the cleaning staff shall be well trained and acquainted with the hazard of pollution and the
importance to prevent it. Records on cleaning and sterilization shall be well made.
6.3.6 Cleaning tools for different clean zones shall be definitely marked and cannot be mixed.
6.4.2.3 Personnel shall enter the clean work areas after procedures such as secondary dressing and hand
cleaning and sterilizing so as to ensure their hand sanitation. They shall wear work clothes, hoods or caps,
work shoes or shoe covers. Work clothes and shoes designated for clean and sub-clean work areas shall
not be worn outside designated areas.
6.4.3 Visitors
6.6.2 Containers for waste, by-products and inedible or hazardous substances shall be well-textured and
waterproof with special marks on. When necessary, they shall be sealed so as to avoid food contamination.
6.6.3 Temporary storage facilities for waste shall be installed in appropriate places, where waste is
classified and stored according to its characteristics. Corruptible waste shall be timely removed.
Management of cleaning agents, disinfectants, pesticides and other poisonous and hazardous substances
shall be in accordance with GB 14881.
Waste water shall be properly dealt with before discharge so as to meet the national requirements for
sewage discharge.
7.2 Requirements for purchase and acceptance inspection of raw and packaging materials
7.2.1 Purchase of raw and packaging materials shall be in accordance with GB 14881.
7.2.3 Once found, food safety problems on raw and packaging materials shall be reported to the local
food safety supervision department.
7.2.4 As to raw materials which directly go into the dry-mixing procedure, integrity of their packages shall
be ensured and no traces of insect pests or other pollution shall be spotted.
7.2.5 As to raw materials which directly go into the dry-mixing procedure, the company shall take
measures to ensure that the microbiological indicator meet the requirements for finished products. It shall be
ensured that the urease activity of soybean raw materials is negative.
7.2.6 Procedures and safety precautions related to suppliers shall be evaluated. Site assessment or
procedures shall be monitored on a regular basis when necessary.
7.3 Requirements for transportation and storage of raw and packaging materials
7.3.1 Companies shall transport and store the raw and packaging materials while meeting the
requirements for quality safety.
7.3.2 During transportation and storage, raw and packaging materials shall avoid direct sunshine, rain,
intensive temperature, humidity change and intensive impact. They shall not be transported together with
poisonous, hazardous substances.
7.3.3 During transportation and storage, raw and packaging materials shall not be polluted and damaged,
thus reducing quality deterioration to the minimum level. Materials and packaging materials which have
special requirements for temperature, humidity or others shall be delivered and stored as specified.
7.3.4 During storage, different raw and packaging materials shall be separately stored according to their
characteristics and labels shall be established to show relevant information and quality conditions.
7.3.5 Stored raw and packaging materials shall be checked on a regular basis. Those raw and packaging
materials which have been stored for a long time and whose quality may have changed must be sampled to
determine their quality. Spoiled or out-of-date raw and packaging materials shall be timely disposed of.
7.3.6 Qualified raw and packaging materials shall be used in accordance with the principle of first-in
first-out (FIFO) or First Expiration First Out (FEFO) so as to be organized in a proper way.
7.3.7 Food additives and food nutritive fortifiers shall be managed by specially-assigned persons. Special
warehouses or zones shall be used for storage and exclusive registers (or warehouse management
software) shall be used to record the names, purchase time, purchase volume and usage amount of
additives and nutrition enhancers. Furthermore, term of validity shall be paid attention to.
7.3.8 Raw material verification shall be done to ensure the qualification of vitamins and mineral
substances which may change during the storage. When necessary, tests shall be done so as to ensure
they meet the requirements for raw materials.
7.3.9 Raw materials which contain allergen shall be separately stored and well marked so as to avoid
cross contamination.
Relevant records on the purchase, acceptance inspection, storage and transportation of raw and packaging
materials shall be kept.
8.2.1.1 The way to kill microorganisms or inhibit microorganism growth and breeding shall be specified
according to the product characteristics, such as heat treatment, freezing or refrigerating storage. Effective
monitoring shall be carried out.
8.2.1.2 Measures to control the temperature and time and to correct errors shall be formulated and verified
on a regular basis.
8.2.1.3 Real time monitoring measures shall be formulated for processing procedures which require strict
temperature and time control. Monitoring records shall be kept.
8.2.2 Humidity
8.2.2.1 Control over air humidity in places where it is required shall be carried out according to the product
and technique characteristics so as to reduce the breeding of harmful microbe. Critical limit of air humidity
shall be formulated and put into effective operation.
8.2.2.2 Real time control over air humidity and monitoring measures shall be formulated to make
verification and keep records on a regular basis.
8.2.3.1 Necessary measures shall be taken during the whole procedure from the inbound raw and
packaging materials to the outbound finished products so as to avoid microbial contamination.
8.2.3.2 The operation, usage and maintenance of equipment, containers and tools which are used to
deliver, carry or store the raw materials, semi-finished products and finished products shall avoid the
contamination to the processed or stored foods.
8.2.4.2 Monitoring plans on microorganisms shall be formulated during the manufacturing process to carry
out effective supervisory control in accordance with GB 14881-2013--Appendix A in combination with
manufacturing techniques and requirements of National Standard for Food Safety--General Rule on
Formulated Foods for Special Medical Purposes and GB 25596--National Standard for Food
Safety--General Rule on Infant Formula Food for Special Medical Purposes. Total bacterial count and the
8.2.4.3 Powder foods for special medical purposes shall be in accordance with Appendix B. Environmental
monitoring plans shall be formulated against the salmonella,enterobacter sakazakii and other
enterobacterium in clean work zones. When the monitored results show deviations, proper corrective
actions shall be taken to the control measures.
8.3.2 Chemical substances shall be separately stored with foods, definitely labeled and kept by
specially-assigned persons.
8.4.2 Work such as electric soldering, incision and polish cannot be done during the manufacture in case
off-flavor and chippings appear.
8.5.1 Food additives and food nutritive fortifiers shall be rationally used according to the types, scope and
dosage specified by National Standard for Food Safety.
8.5.2 When being used, food additives and food nutritive fortifiers shall be accurately weighed and
recorded.
8.6 Packages
8.6.2 Packing materials shall be clean, non-toxic and in accordance with relevant national regulations.
8.6.3 Packaging materials or gas shall be non-toxic and shall not affect the food safety and product
features under special storage and usage conditions.
8.6.4 Reusable packaging materials such as glass bottle and stainless steel containers shall be
thoroughly rinsed and sterilized before being used.
All treatment procedures in the manufacturing techniques of formulated foods for special medical
purposes shall meet the requirements of corresponding specific processing steps and be in accordance with
8.7.2 to 8.7.9.
The heat treatment procedure shall be the critical control point to ensure the safety of formulated foods for
special medical purposes. As to the heat treatment temperature and time, the impact of factors such as
product attributes (such as fat content, total solid content) on heat resistance of target microorganisms shall
be considered. So relevant procedures shall be formulated to see if the temperature and time is deviated
and proper corrective actions shall be taken.
When the purchased soybean raw materials fail to go through heated enzyme deactivation treatment (or the
enzyme deactivation is incomplete), such soybean-based products shall go through the heat treatment while
achieving the desired effect of pathogen killing and thorough enzyme deactivation (the urease shall be
negative) and be monitored as a critical control point.
Records on critical process parameters such as the time, temperature and enzyme deactivation time in the
heat treatment shall be kept.
During the production of formulated foods for special medical purposes, relevant measures shall be taken in
the intermediate storage of liquid semi-finished products so as to prevent the growth of microorganisms.
Raw material powder that is exposed during the dry production of powder formulated foods for special
medical purposes or powder semi-finished products which are exposed during wet production shall be
stored in the clean work zones.
8.7.4 Commercial sterile operation of liquid formulated foods for special medical purposes
8.7.5 Processing steps of powder formulated foods for special medical purposes from heat
treatment to dryness
During the production of powder formulated foods for special medical purposes, the running pipes and equipment
shall be airtight from heat treatment to dryness and be thoroughly cleaned and sterilized on a regular basis.
8.7.6 Cooling
The dry, exposed powder semi-finished products shall be cooled down in the clean work zone.
8.7.7 Key factor control over the dry blending in dry process of powder formulated foods for
special medical purposes and dry-wet compound technology
8.7.7.1 The exposed powder process that is in contact with the air (such as premixing, sub-packaging and
batch charging) shall be carried out in the clean work zone. The temperature and relative humidity in the
clean work zones shall be in accordance with the manufacturing techniques of powder formulated foods for
special medical purposes. When there is no special requirement, the temperature shall be 25℃or lower and
the relative humidity shall be below 65%.
8.7.7.2 The batching shall be accurately calculated. There shall be review processes during the calculation
of food additives and food nutritive fortifiers.
8.7.7.3 Critical process parameters (such as mixing time) related to mixing uniformity shall be verified. The
mixing uniformity shall also be determined.
Copyright @ 2015 The Sovereign Group All Rights Reserved
293
8.7.7.4 Compressed air which is needed to transfer materials with positive pressure shall only be used after
the oil and water removal, cleaning, filtering and sterilization.
8.7.7.5 Sanitary control requirements for raw materials, packaging materials and personnel shall be strictly
formulated. The raw materials shall enter the work zones via the necessary cleaning procedures and
material channels. They shall be in accordance with the treatment procedure of outer package removal or
outer package sterilization.
8.7.8 Key factor control over the inner packing of powder formulated foods for special medical purposes
8.7.8.2 The wrapping room shall only be accessible to relevant personnel. Requirements for raw and
packaging materials and the personnel shall be in accordance with 8.7.7.5 and 6.4.2.
8.7.8.3 The outer packages of the packaging materials shall be examined before use to see if they are intact
so as to ensure that these materials are not contaminated.
8.7.8.4 Manufacturers shall take effective measures to control, prevent and inspect the extraneous
substances. For example, screens, strong magnets and metal detectors shall be installed. Supervisory
control or validation verification shall be carried out on the procedures of these measures.
8.7.8.5 When different types of products are produced on the same assembly line, they shall be cleaned in
an effective way and site-clearing records shall be kept so as to ensure that product switch doesn’t affect the
next group of products.
8.7.9.1 Production water supply, equipment cleaning water, ice and steam which is in direct contact with
foods shall be in accordance with GB 5749--Hygienic Standard of Drinking Water.
8.7.9.2 Recycle-water from the steam or dry process in the food processing or water in cycle use can be
reused, but they shall not jeopardize the food safety and product features. Water treatment and effective
monitoring shall be carried out when necessary.
8.7.9.3 When liquid products are produced, production water in direct contact with the products shall be
manufactured with the de-ionization method or ion exchange method, reverse osmosis method and other
proper methods according to the characteristic of the products so as to ensure that the requirements for
product quality and technology can be met.
9. Verification
9.1 The productive process shall be verified so as to ensure the reproducibility of the whole process and the
controllability of the product quality. The production verification shall include the installation determination,
operation determination, performance determination and product verification of plants, facilities and
equipment.
9.2 Verification projects shall be put forward according to the verified objects. Verification schemes shall be
formulated and implemented.
9.3 Manufacturing techniques and key facilities and equipment of the products shall be verified according to
the verification schemes. When key factors which affect the product quality (including the nutrient content)
Copyright @ 2015 The Sovereign Group All Rights Reserved
294
change, such as the technologies, quality control methods, main raw materials, main production equipment,
or when the production has undergone a period, re-validation shall be carried out.
9.4 After the verification is done, test reports shall be written and then examined and approved by verifiers.
Data and analytical content during the verification shall be recorded in files. Verifying files include verification
schemes, verification reports, comments and Suggestions, approvers, etc.
10. Test
10.2 Representative samples shall be taken from finished products group by group. The samples shall be
tested and kept in accordance with the relevant national regulations and standards.
10.3 Quality control over the labs shall be strengthened so as to ensure the accuracy and authenticity of
verification results.
11.2 Storage and transportation of products shall be in accordance with the storage condition on their labels.
11.3 Products in the warehouses shall be checked on a regular basis. Temperature and/or humidity records
shall be kept when necessary. Abnormal situations shall be immediately processed when occurring.
11.5 Relevant records shall be made on the storage and transportation of products. Outbound products shall
bear delivery records so that they can be recalled immediately when problems occur.
12.1 Product tracing systems shall be formulated to ensure that products can be effectively traced during the
whole process from raw material purchase to product distribution.
12.2 Product recall systems shall be formulated. When a group or a type of products are found to or be likely
to jeopardize the consumers’ health, product recall systems shall be launched according to the relevant
national regulations. Relevant departments shall be immediately notified and relevant records shall be
made.
12.3 Measures such as non-hazardous treatment and destruction shall be taken after the foods are recalled.
Relevant departments shall be notified of the food recall and processing.
12.4 Customer complaint and processing systems shall be formulated. Relevant company management
departments shall keep records of and find the reasons to the customers’ written or oral advice and
complaints before appropriately solving them.
13. Training
14.2 Perfect food safety management systems shall be formulated and relevant management measures
shall be taken to carry out safety quality control over the formulated foods for special medical purposes
during the whole process from the inbound raw materials to outbound finished products so as to ensure that
products are in accordance with laws and regulations and relevant standards.
14.3 Supervision organs of food safety shall be established to manage food safety.
14.4 Head of the above organ shall be the legal representative or a person-in-charge assigned by the legal
representative.
14.5 Different departments within the organ shall have their definite management responsibilities to ensure
that management responsibilities related to quality and safety are put in place. Every department shall have
its effective division mechanism to avoid responsibility overlapping, repetition or absence. Corresponding
management systems shall be formulated for the maintenance and management of the inside and outside
plant environments, plant facilities and equipment, the quality safety management during the production,
sanitary control and quality tracking. The managers and their responsibilities shall be clear and definite.
14.6 Supervision organs of food safety shall be equipped with especially trained food safety managers who
are responsible for publicizing and implementing food safety regulations and relevant rules, as well as
supervising the implementation of examination and keeping relevant records.
15.1.2 All records shall be signed or stamped by executives or relevant supervisors for review. Once altered,
the records shall be clear enough to show their original appearance. Modifiers shall sign or stamp the area
near the words.
15.1.3 All production and quality management records shall be examined and verified by relevant
departments so as to make sure all the processing is in accordance with regulation. When occurring,
abnormal events shall be dealt with immediately.
File management systems shall be formulated in accordance with GB 14881 and intact quality management
files shall be established. Files shall be classified and stored. Files for distribution and use shall be approved
current texts. The abolished or invalid files shall be only stored for inspection. They shall not appear at the
working sites.
Monitoring and evaluation measures in Appendix C shall be taken to ensure the effectiveness of food safety
control measures for powder formulated foods for special medical purposes.
Appendix A
A.1 Computer systems for manufacturers of formulated foods for special medical purposes shall be in
accordance with Food Safety Law and relevant laws, regulations and standards on food safety. An
integrated information link which supports the traceability, tracing and location of food safety during all
processes from inbound raw materials to outbound products. Relevant data shall be submitted or reported
from a long distant away according to the requirements of supervision departments. This computer system
shall be in accordance with but not limited to the requirements of A.2 to A.11.
A.2 The system shall include the purchase and acceptance check of raw materials, storage and use of raw
materials, supervisory control over the critical control links of production and processing, outbound product
inspection, storage and transportation of products, distribution and other links, as well as the collection of
data related to food safety and record retention.
A.3 The system shall be able to evaluate and send pre-warning about related raw materials, processing
techniques and risks of food safety.
A.4 Perfect authorization management mechanisms shall be formulated in the system and the matched
database so as to ensure the mandatory usage of workers’ accounts/passwords. Bugs which allow
unauthorized access shall not be allowed in the systems and database on the security architecture.
A.5 The system shall achieve perfect safety strategies based on the authorization management mechanism
and ensure that specific role users only have their corresponding authorities by setting up strategy groups
according the different workers. All data which the system is in contact with and produce shall be saved in
the corresponding database. They shall not be saved as files so as to ensure access to all data is subject to
the authority management control of the system and database.
A.6 Special security strategies taken to the confidential information ensure that only information owners
have the right to read, write and cancel the information. If it is required that confidential information be saved
and transmitted outside the safety control scope of the systems and database, the following shall be
guaranteed:
a) To encrypt and save confidential information in case the information is read by unauthorized persons.
b) Check codes shall be generated before the transmission of confidential information; Check codes and
information (encrypted) shall be separately transmitted; Check codes shall be used at the receiving end so
as to ensure the information is not falsified.
A.7 If the system requires to collect data generated by automation detecting instruments, the system shall
provide safe, reliable data interfaces and guarantee their accuracy and high availability, thus ensuring the
data generated by instruments can be timely and accurately collected by the system.
Copyright @ 2015 The Sovereign Group All Rights Reserved
297
A.8 Log management functions of complete, exhaustive systems and database shall be achieved, which
includes:
a) Every user log-in on the system’s logging system and database (users, time, locations of log-in
computers);
b) Every alteration of the logging data (including the altering users, altering time, altered content, original
content, etc);
c) Conversation strategies shall be in the system log and operation log. They shall not be canceled or
altered by any user (except for the administrators) within the set time limit so as to guarantee some time
traceability.
A.9 Detailed usage and management system shall be formulated and contain at least the following:
a) To formulate the real-time record system to record the original data, intermediate data, generated data
and process flow during the work flow so as to reproduce the whole working process;
b) To formulate detailed backup management systems to ensure that the whole system and corresponding
data can be recovered as soon as possible after failures occur;
c) The machine rooms shall be equipped with smart UPS to be linked with work systems and ensure that
UPS can supply power and warn the work system to carry out data storage and log operation when power
failures occur outside. (UPS can supply the power to guarantee the operation time of system emergency
saving);
d) Perfect data access management systems shall be formulated and restricted data shall not be saved on
shared device. Authority management systems shall be applied to the internal data sharing to achieve
authorized visit;
e) Matched system maintenance mechanisms including regular storage arrangement and system detection
shall be formulated to ensure the long-term stable operation of the system;
f) Safety management systems shall be formulated. User passwords for the systems shall be replaced on a
regular basis. Log-in sites of some users shall be restricted and unnecessary accounts shall be canceled.
g) It shall be specified that users who log in on outer nets shall not start and use the user/password memory
function provided by the operating systems of outer computers so as to prevent the information from being
embezzled.
A.10 When the data from the real-time monitoring of critical control points are inconsistent with the set
standard values, the system can record the deviation dates, batches, the way to rectify the deviation and
operator names.
A.11 Data and relevant records in the system shall be reproducible so as to be inspected and analyzed by
supervisors.
B.1.1 There may be a small amount of Enterobacteriaece even in the sanitary production environments,
including enterobacter sakazakii (belonging to Cronobacter). Pasteurized products may also be polluted by
the environments, leading to the fact that a small amount of enterobacterium remains in the products. So
enterobacterium in the production environments shall be monitored so as to determine whether the
sanitation control procedure is effective. When deviation occurs, manufacturers shall take corrective actions
and acquire the basic data of the hygiene status through continuous monitoring to trace the trend changes.
According to relevant practices in the factory, reduction of the amount of enterobacterium in the
environments can help decrease the enterobacterium in the final products (including enterobacter sakazakii
and salmonella).
To prevent the contamination accidents and avoid the limitation of microbial sampling test in the final
products, environmental monitoring plans shall be formulated as a food safety management tool and a basic
procedure for Hazard Analysis and Critical Control Point(HACCP)to evaluate the sanitary conditions in
clean work areas (dry areas).
B.1.2 Factors such as the ecological characteristics of salmonella, enterobacter sakazakii and other
enterobacterium shall be considered when monitoring programs are formulated. Supervisory control over
enterobacter sakazakii shall only be applicable to formulated infant foods for special medical purposes.
Salmonella can rarely be found in dry environments. Monitoring programs, however, shall be formulated to
prevent its access. Effectiveness of hygiene control measures in the production environment shall be
evaluated and relevant personnel shall be taught to prevent the salmonella from spreading when salmonella
is found.
Enterobacter sakazakii is easier to be found in dry environments than salmonella and more likely to be
detected with proper sampling and testing ways. Monitoring programs shall be formulated to appraise
whether enterobacter sakazakii is increasing. Effective measures shall be taken to prevent its growth.
Enterobacterium, a common bacterium group in dry environments, is wide spread and easy to detect.
Enterobacterium can be used as the indicator bacterium for environmental health conditions or during the
production.
B.2 Factors which need considering in the design and sampling plans
The requirements and scope for sampling plans shall be determined according to the product feature,
consumers' age and health conditions. In the standard, salmonella and enterobacter sakazakii are defined
as pathogenic bacteria.
The emphasis of supervisory control shall be put on areas where microorganisms are likely to hide, such as
the clean work area in the dry environments. Junctions between this area and the lower-level adjacent
zones, as well as places that are close to the production line and equipment and are likely to be
Copyright @ 2015 The Sovereign Group All Rights Reserved
299
contaminated, shall be paid more attention to, such as the opening of the enclosed equipment which is
casually used for inspection. Areas that are known or may be contaminated shall be prioritized in
supervisory control.
B.2.2.1 Sampling from the surfaces which are in no touch with the food, such as equipment exteriors, ground
around the production line, pipes and platforms. Under such circumstances, pollution risk degrees and
pollutant content shall depend on the location and design of the production line and equipment.
B.2.2.2 Sampling from the surfaces which are in direct touch with the food, such as the equipment which
may directly contaminate products from the spray tower to packaging. For example, microorganisms may
breed at the sieve end due to the water absorption of clotting powdered formulas. Products are exposed to
high contamination risks if indicator bacteria, enterobacter sakazakii or salmonella remain on the food
contact surface.
Salmonella and enterobacter sakazakii are main target microorganisms. But the enterobacterium can be
used as hygienic target bacteria. The enterobacterium content may show the possibility of salmonella to
exist, as well as the conditions for salmonella and enterobacter sakazakii to grow.
Sample amount shall be adjusted according to the complexity of techniques and the production line.
Sampling locations can be places where microorganisms may hide or go into so that contamination is
caused. Sampling locations shall be determined according to relevant document literature or experience and
expertise or historical data collected from factory pollution survey. Sampling locations shall be evaluated on
a regular basis and necessary sampling locations shall be added to the monitoring programs according to
special circumstances such as heavy maintenance, construction activities or worse sanitary conditions.
Sampling plans shall be comprehensive and representative. Scientific, rational sampling from various
production shifts and different time frames in these shifts shall be considered. Sampling shall be carried out
before production to verify the effect of cleaning measures.
The sampling frequency shall be determined according to B.2.1 and the data of existing microorganisms in
different regions within the monitoring programs. If there are no such data, information shall be fully collected
so as to determine the rational sampling frequency, including the long-term collection of the occurrence of
salmonella or enterobacter sakazakii.
Implementation frequency of environmental monitoring plans shall be adjusted according to the testing
results and severity of pollution risks. When pathogenic bacteria are detected in the final products or when
the indicator bacteria increase, environmental sampling and investigation sampling shall be intensified so as
to find the pollution source. When pollution risks increase (for example, after the maintenance, construction
or wet cleaning), sampling frequency shall be properly increased.
Sampling tools and methods shall be selected according to the surface types and sampling locations. For
Copyright @ 2015 The Sovereign Group All Rights Reserved
300
example, surface residues or powder in the dust collectors shall be directly chosen as samples. For larger
surfaces,sponges or swabs shall be used for wiping sampling.
Analytical methods shall be able to effectively detect target microorganisms with acceptable sensitivity and
relevant records. On the basis of sensitivity, many samples can be detected together. If the outcomes are
positive, the locations of positive samples shall be further determined. When necessary, information on the
source of enterobacter sakazakii and pollution path of powder formulated foods for special medical purposes
shall be analyzed with the genetic technology.
Monitoring programs shall include data records and evaluating systems, such as the trend analysis.
Constant evaluation must be made on data so as to properly alter and adjust monitoring programs. Effective
management shall be carried out on the data of enterobacterium and enterobacter sakazakii. Neglected
slight or discontinuous pollution may be found.
Monitoring programs aim to find whether target microorganisms exist in the environments. Before the
monitoring programs are formulated, acceptance standards and countermeasures shall be formulated.
The concrete action strategies and relevant reasons shall be specified in the monitoring programs. Related
measures include no actions (no pollution risks), to strengthen the cleaning and pollution source tracing (to
intensify the environmental testing), to evaluate sanitary measures, to seize and detect products.
Action strategies shall be formulated by manufacturers after enterobacterium and enterobacter sakazakii are
detected so as to accurately respond to the abnormal situations. Sanitation procedures and control
measures shall be evaluated. Corrective actions shall be taken immediately after salmonella is detected.
Enterobacter sakazakii trend and changes of enterobacter amount shall be evaluated. Actions to be taken
shall depend on the possibility of products being contaminated by salmonella and enterobacter sakazakii.
Besides the regulations which are applicable to liquid formulated foods for special medical purposes in the
standard, the commercial sterile operation of liquid products shall also be in accordance with C.2 to C.6.
C.2.1 Operation of all techniques shall be performed under the good conditions which are in accordance
with the technique requirements.
C.2.2 Processes which are in contact with the air (such as weighing and batching), bottling rooms and
auxiliary areas with special requirements for cleanness shall meet the requirements for liquid formulated
foods for special medical purposes.
C.2.3 All the delivery pipes and equipment for the products shall be airtight.
C.2.4 Liquid products shall be filtered during the production. Filter materials with no fiber exfoliating and
meeting the sanitary requirements shall be used. Asbestos shall not be used as filters.
C.2.5 Control measures shall be formulated to prevent extraneous matters from entering the products during
the production.
C.3.1 Food containers, packing materials, detergents and disinfectants which are in accordance with the
national food safety standard and the permission of health administrative departments shall be used.
C.3.2 The washed packaging materials, containers and equipment shall not be contaminated for the second
time.
C.3.3 Packaging materials used in sterile filling systems shall be sterilized in a proper way. They shall be
washed and dried when necessary. After sterilization, they shall be stored in clean work areas for use.
Sterilization shall be performed again when storage period exceeds the set time limit.
C.4 Washing, sterilization and clean-keeping of product processing equipment for aseptic filling technology
C.4.1 Before production, water, filtered steam, fresh distilled water or other proper treating agents under high
temperature pressing shall be used to keep the products under high temperatures or clean and sterilize all
the pipes, valves, pumps, feeding hoppers and other product contact surfaces in the lower reaches of the
pipeline. It shall be ensured that all surfaces that are in direct contact with the products shall meet the
requirements of sterile filling and remain until the production is over.
C.4.2 Sterile warehouses for filling and packaging equipment shall be cleaned and sterilized, and meet the
requirements of aseptic filling before the production. They shall remain until the production is over. When
sterilization fails, sterile warehouses shall be sterilized again. Key indicators such as the time, temperature
and disinfectant concentration shall be controlled and recorded when sterilization is carried out.
C.5.1 Automatic mechanical devices shall be used for product filling. No manual operation shall be allowed.
C.5.2 As to all products which need to be sterilized after filling, the time from bottling to sterilization shall be
limited within the time required by the technological procedures.
C.5.3 As to the sterilized products, monitoring standards for pollution levels of product microorganisms
before sterilization shall be determined according to the effects of the used sterilization methods and
monitored on a regular basis
C.6.1 Proper heat treatment processes shall be formulated according to the quality of product heating and
the dynamics to kill specific target microorganisms. Products shall be heated to the sterilizing temperature
and remain at the temperature for some time to achieve commercial sterilization. All the heat treatment
processes are verified so as to ensure the reproducibility and reliability of the techniques.
C.6.2 Liquid products shall be sterilized with thermal sterilization as much as possible. Thermal sterilization
is usually divided into damp-heat sterilization and dry-heat sterilization. The products to be sterilized in the
chambers of sterilizing equipment and the way to carry materials shall be determined via verification.
Time-temperature curve of every sterilization process shall be recorded. There shall be definite ways to
distinguish sterilized products from products that are to be sterilized. Sterilization records shall be the basis
to permit the group of products.
C.6.3 Constant flowing products which adopt the aseptic filling technique shall remain at the sterilizing
temperature in the high temperature sterilization places or within the pipe flowing time so as to achieve
commercial sterilization. So, product types, as well as the size and design of flow rate, pipeline length and
high temperature sterilization places of every product shall be accurately determined. When steam injection
or other steam filling way is used, product size increase due to the water caused by vapor condensation
shall be considered.