0% found this document useful (0 votes)
2K views3 pages

DNT T103

The document describes a network thermostat that displays temperature and other values. It can connect to Delta's proprietary LINKnet network or a BACnet MS/TP network. It has an LCD display, buttons, temperature sensor, and inputs/outputs that allow it to control HVAC equipment directly or integrate with a controller.

Uploaded by

mathurashwani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views3 pages

DNT T103

The document describes a network thermostat that displays temperature and other values. It can connect to Delta's proprietary LINKnet network or a BACnet MS/TP network. It has an LCD display, buttons, temperature sensor, and inputs/outputs that allow it to control HVAC equipment directly or integrate with a controller.

Uploaded by

mathurashwani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

NETWORK THERMOSTAT

BACSTAT II™ DNT-T103


3-value; 96-segment with LCD Display
Description SPECIFICATIONS

The DNT-T103 BACStat II™ is an intelligent room sensor with a custom 3-value, 96 segment, LCD
LCDdisplay that is used with Delta’s™ BACnet™ Application Controllers which are capable of
3-value & various icons (96 total
communicating on Delta’s™ proprietary LINKnet™ network or directly on a BACnet™ MS/TP segments) w/optional backlighting
network.
Push Buttons
It is capable of displaying a wide range of digital or analog values, including setpoints,
4 stylized momentary push
temperature, air flow, heating and cooling status, fan speed, valve and damper position and buttons
more.
Temperature Sensor
When connected to an Application Controller
Thermistor Input - 10K Ω at 77°F
on a LINKnet™network it provides programmable (25° C)
remote sensor and expanded I/O capabilities to Accuracy +/-0.36° F from 32-158° F
the controller. When connected on the MS/TP (+/- 0.2° C from 0-70° C)
network, it functions as an independent BACnet™ Display resolution of 0.1°
sensor device.
Stability 0.24° F over 5 years
(0.13° C)
Application
Inputs - External
With 1 external universal input,
and 3 binary outputs and built-in 1 Universal Input - 10 bit
(supporting 0-5v, 0-10v, 10K)
control applications, the DNT-T103 is
capable of simple stand alone control Outputs - External
when directly connected on an MS/TP DNT-T103 Network Thermostat 3 Binary Triac outputs
network. (supporting Binary, PWM or Tri-State)
Features
Diverse applications include VAV, VVT Technology
> Native BACnet™ thermostat
Fan Coil Units, Unit Heaters, Radiation 8-bit processor c/w internal A/D,
or Reheat Control, Furnace, and other > Supports communicating on Flash and RAM >>
room applications. LINKnet™ or directly on an RS-485
MS/TP network
The DNT-T103 may also be connected
to a LINKnet™ network to provide > Programmable 3-value, 96 segment,
remote sensor and I/O mixing LCD display (via GCL over LINKnet™)
capabilities. with optional backlighting
> 4 Programmable buttons (via GCL
over LINKnet™)
> Derived Network Addressing (DNA)
for logical integration into a standard
network architecture
> Field selectable applications

Integrated Facilities Management Solutions. Simplified!


Delta Controls Inc. Technical specifications are subject to
17850 56th Avenue Tel: (604) 574-9444 revision without notice.
Surrey Fax: (604) 574-7793
British Columbia www.deltacontrols.com
Canada V3S 1C7 Rev. 09_01
NETWORK THERMOSTAT
BACSTAT II™ DNT-T103
SPECIFICATIONS (cont.)
Triacs
Connector Posts
for IP2 Device Type
Connector Posts Connector Posts
for Outputs for 24 VAC Configurable as a LINKnet™ or
OP3 COM OP2 COM OP1 [-] [+] IP2 GND ~24
Subnet device

INTERNAL
Connector Posts

EXTERNAL
1 2 1 2 3 1 2 1 2 3
Output Power for Network
Source Selector
Blocks (OP3) EXTERNAL
INTERNAL
Input Type Selector Device Addressing

10K 10V 5V
Blocks (IP2)
+
+ Set via Keypad Configuration Setup
Output Power
Source Selector
Blocks (OP1 & 2)
Standard Device Address Range
(via Keypad): 0-8 on LINKnet™ or
0-99 per MS/TP network segment
RESET
High Voltage
CPU
WARNING Warning - when Communications Ports
HIGH VOLTAGE devices with
AREA
backlighting are BACnet™MS/TP @ 9,600 or 19,200
powered on.
or 38,400 or 76,000 bps
(maximum of 99 nodes per MS/TP
segment)
698128 Rev 2.0
RJ II Service Port
Connectors
[-]

Thermistor
(Other Side of PCB)
Removable screwtype terminal
~24
[+]

Service
Port connectors
Wiring
2 for RS-485 LAN
Board Layout DNT-T103
2 for Power
Additional wiring for external inputs
and outputs
Wiring Class
Class II
Power
24 VAC , 2VA net including
output loading >>

Integrated Facilities Management Solutions. Simplified!


NETWORK THERMOSTAT
BACSTAT II™ DNT-T103
SPECIFICATIONS (cont.)
Ordering
Ambient
Order the Delta BACstat™II with the desired options according to the following
product numbers. 32° to 131° F (0° to 55°C)
10 - 90% RH (non-condensing)
Features DNS-24 DNT-T103 DNT-T221 Dimensions
Internal Thermistor Input ● ● 4.5 x 2.75 x 1.25 ins
(11.4 x 7 x 2.5cm)
Additional I/O (1 IP & 3 OP) ●
0.1 lb (50 g)
4-Button Model ● ●
Approvals/Standards
Backlighting Option B Option B Option B
UL916; CE; FCC Class A
Button Icons G1, G2, G3 G1, G2, G3 As Specified

Note: For the 4-Button Models, an appended button icon code must be included to
specify the desired icons embossed on the buttons as follows:
Default Bottom 2 buttons are ▼ & ▲ (Setpoint Adjust), top 2 are OFF and ON
INT Bottom 2 buttons are ▼ & ▲ (Setpoint Adjust), top 2 are O and I -
International
FAN Bottom 2 buttons are ▼ & ▲ (Setpoint Adjust), top 2 are INCREASE
and DECREASE Fan Speed

Accessories
RPT-768 Delta Network Repeater for MS/TP
TRM-768 Delta Network Terminator for MS/TP
CON-768 Delta Network Converter