Olympus Keymed Group Ltd. Olympus Corporation Keymed Limited
Olympus Keymed Group Ltd. Olympus Corporation Keymed Limited
KeyMed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, United Kingdom Olympus Corporation KeyMed Limited
Telephone: +44 (0)1702 616333 Fax: +44 (0)1702 465677
e-mail: [email protected] www.olympusindustrial.com
OLYMPUS CORPORATION
Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan
OLYMPUS INDUSTRIAL AMERICA INC.
One Corporate Drive, Orangeburg, New York 10962, USA
OLYMPUS SINGAPORE PTE LTD.
491B River Valley Road #12-01/04, Valley Point Office Tower, Singapore 248373
OLYMPUS HONG KONG AND CHINA LIMITED.
Room 518, 5F, Ocean Center 5, Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong
OLYMPUS MOSCOW LIMITED LIABILITY COMPANY
117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, Russia
OLYMPUS AUSTRALIA PTY. LTD.
www.olympusindustrial.com 31 Gilby Road, Mount Waverley, Victoria 3149, Australia
Printed in UK 5048362/1103 09 OLYMPUS INDUSTRIAL VIDEOSCOPE SYSTEM OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 09
System Charts
Olympus Industrial Endoscopes
meet needs across a wide range of areas, FIBERSCOPES AND RIGID BORESCOPES
from maintenance to R & D
Eyeball Observation System Digital Photography System
Olympus technology has made it possible to obtain views from internal or difficult to reach areas, easily and quickly,
Olympus
without teardown or disassembly, and without destroying exterior features. Digital Camera Adaptor CAMEDIA
AI-DC3/AK-DC3
Olympus has a comprehensive range of industrial endoscopes, such as videoscopes, fiberscopes and borescopes, with a Digital Camera
range of ancillary equipment to match your specific requirements. These scopes, all designed and made by Olympus, offer Industrial Fiberscope Optical
Adaptor
superior imaging and performance achieved through combining Olympus expertise in optics, electronics and precision
mechanics gained through years of experience. With the ease of use and durability of Olympus products, it is clear that Video System
Olympus Industrial endoscopes can make a large contribution to productivity, safety and reliability in your industry. LCD Monitor
Light Source
Rigid Borescope
C-Mount
Adaptor Video Monitor
SOME APPLICATION EXAMPLES Light Guide Cable
TV Camera VCR
Aerospace Industries Small Diameter Borescope
For examination of Airframe and Gas turbines in research,
production and maintenance for military and civil aircraft. Also Video Printer
rockets and rocket engines.
OM Adaptor
Security
For detection of Narcotics and other contraband items, for bomb
Image Recorder PCMCIA PC
and weapons searches, and for locating those trapped following IW-R1 Memory Card
disasters.
Power Generation
For maintenance of heat exchange pipes, condensers, piping and Film Photography Digital Storage and
Measurement System
Floppy Disk
Flash Path PC
turbines at nuclear, fossil fuel and hydroelectric power generation System DSM-2
facilities.
Industrial Machinery
For quality control and maintenance of motors, boilers, heat
exchangers and machine tools.
Refineries/Chemical Plants
For routine and urgent inspection of process piping, pressurised
storage reservoirs, heat exchangers, boilers etc.
Automotive
For quality control examinations of engines, hydraulic components
and injection nozzles, as well as detection of leaks, squeaks and
rattles in assembled vehicles.
Electrical Equipment/Electronics Industries
For monitoring operation of equipment and factory automation
through automatic inspection and positioning, as well as a wealth
of R & D applications.
Gas Pumping & Delivery Systems
For monitoring corrosion inside and outside gas pipes, the
presence of water infiltration and flaws in outlets, and for
maintenance of gas turbines used for pumping.
Steel Industries
For equipment maintenance as well as quality control of pipes and
tubes.
Architecture/Construction
For examination of walls, ducts, structured joints, as well as for
viewing inside architectural models.
Education/Research
For monitoring animals and insects, root systems of plants etc.
Also for historical and archaeological applications such as internal
inspection of statues and tombs.
Railroad/Shipping
For routine inspection of motors, turbines, diesel engines, piping etc.
Water Supply/Drainage
For locating rust and blockages inside pipe systems.
Useful for documentation before and after lining is coated.
02 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 23
System Charts Industrial Videoscopes
Flexible portion
VCR Light guide fiber Light source
Depth of field Bending section Electronic control unit
Objective lens
and optical tip adaptor
Remote control
USB or
Recording Card
Ultra-compact CCD for image transmission.
PC 4 way Tip Angulation Optical Tip Adaptors
High-resolution images are displayed on a TV monitor.
The videoscope captures light reflected from a subject through an
objective lens and directs it to the surface on the CCD. The CCD then
IPLEX SX converts the light into electrical signals and transfers this data to the
3D Eye-Trek
videoscope control unit. The unit then sends a video output to the monitor.
MAIN APPLICATIONS
Optical Adaptors Remote Control Ideal when higher resolution, longer insertion and
Extension Cable brighter images than those obtainable with fiberscopes Forward/Side-Viewing Adaptor Ultra-Wide-Angle Adaptor
22 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 03
Industrial Videoscopes Accessories
3D EYE-TREK (for IPLEX) CCTV EQUIPMENT
FMD-3DN (NTSC) Various CCD cameras, CRT and LCD monitors and video recording
equipment products are available for TV observation.
FMD-3DP (PAL) For details of the latest models, contact your local Olympus sales
Allows you to confirm the conditions of an inspection site with super- representative.
real three-dimensional images. 3D Eye-Trek makes it easier to get an
accurate sense of distance, also facilitating insertion of the scope and
IPLEX SERIES access to the site.
04 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 21
Accessories Industrial Videoscopes
Viewing Adaptors Engine Turning Tools 3D EYE-TREK STEREO MEASUREMENT (IPLEX SA STEREO MEASUREMENT)
These adaptors allow the eyepiece of a rigid borescope or flexible The Olympus Electronic Engine Turning Tool (OTT) can offer increased Olympus’s stereo measurement technology uses triangulation to
When the 3D Eye-Trek face-
fiberscope to be extended or angled for a more comfortable viewing speed and efficiency for all internal turbine inspections. Using a simple measure image information captured by two parallax lenses. With six
mounted display is connected to
position. hand held controller each blade can be precisely positioned for an different measurement modes available, high-precision measurement
the remote control, surface
optimal view, allowing single operator inspections. The Engine Turning capabilities are available from any angle.
contours that would normally be
Tool is designed to be attached to engines quickly and easily - the Distance:
difficult to detect can be observed Measures the total length of a defect or
engine-specific adaptor connect the drive motor directly to the engines’
in three dimensions where they zone of damage.
gearbox turning point or air starter position. Once connected the
can easily be interpreted. Point-to-Line:
operator can select rotation speed and direction (forward or reverse). Measure the distance between a
The Olympus Turning Tool is suitable for use on most turbine engines for hypothetical line between two designated
aerospace and power generation applications. positions and the required point.
Depth:
The Olympus Turning Tool uses an electric stepper motor rather than Measures the depth/height of corrosion,
compressed air, making its operation precise, quiet and efficient. The protrusion and indentation from a
range consists of four different models, depending on the specific engine hypothetical plane to the required point.
Lines:
requirements. Features include blade identification on an easy to read
Total length of a crack with complicated
LED, convenient foot switch, offering hands-free operation and many Left Right
contours can be measured by plotting
other specific features, outlined below. multiple positions.
3D Image Area:
● OTT-1 Calculates the area of a burn or zone of damage
■ IPLEX Equipment Components and Functions surrounded by multiple designated positions.
This turning tool package is a high specification unit. A complete kit
Profile:
includes a Central Processing Unit, Hand Controller, Foot Pedal, IPLEX SA IPLEX SA IPLEX IPLEX SX
■ Viewing Adaptors Specifications STEREO MEASUREMENT Hard-to-see irregularities are simulated with
Software Module, Engine Adaptor and all required cables. Features of Scope Variation computer graphics for easier analysis.
Adaptor Name Angle Arm Length / Magnification
this turning tool include video overlay, variable torque settings, Outer diameter Insertion tube length Product code
AK2-18-90 90° angle 18cm arm interchangeable engine adaptor, backlash compensation, blade counting ø4.4mm
3.5m IV7435A IV7435A IV7435 –
PC SOLUTION (IPLEX SA and SX PC COMPATIBILITY)
4.0m – – – IV7440X1
AK2-9-60 60° angle 9cm arm and tagging, auto indexing and adjustable rotation speed, direction and All aspects of inspection operation can be controlled with a PC
3.5m IV7635A IV7635A IV7635 IV7635X1
AK2-8-90 90° angle 8cm arm
dwell time. 5.0m IV7650A IV7650A IV7650 – connected to IPLEX via a USB cable. Stored image data can also be
ø6.0mm
20 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 05
Industrial Videoscopes Accessories
IPLEX SX SERIES
INDUSTRIAL VIDEOSCOPE SYSTEM
IPLEX SX 6.2mm (with channel) 35mm SLR CAMERA
IPLEX SX 4.4mm SC35 (Type 15)
Purpose-built to meet the specific requirements of gas turbine By using an optional OM Adaptor, images observed by an Olympus
inspection, the new IPLEX SX provides improved access to intricate Industrial fiberscope or borescope can be easily photographed with
engine interiors, enhanced hooking and retrieval operation for automatic exposure.
exceptional ease of use, together with all high-quality capabilities Note: Ordinary photography is not possible with this camera.
synonymous with Olympus, such as advanced observation performance
and proven stereo measurement.
● All features of the IPLEX SA unit including stereo measurement plus
working channel in 6.2mm model.
● Control unit can be removed from case for enhanced portability.
■ IPLEX SX Optical Adaptor Specifications camera alone, and the internal view can be documented when the IF3 Series SM-2S 1 1.0 1.0
Optimized for jet engine inspection Optical System Distal End camera is connected to the endoscope. IF7D3X3-26, 32
IF13D3-60, IF8D3X2-23
Scope Optical Adapter
Field Direction Depth F Outer Rigid distal Image Carriers SM-3S 2 1.375 0.529
Olympus’s innovative Tapered Flex
of view of view of field No. diameter end length*
technology is well known for its unequaled AT120D/NF-IV76X1 120º 4~190mm 9.2 20.6mm IF4D4/4S4, IF5D4X1 AI-3M 3 1.0 1.0
insertion capability. The IPLEX SX’s Forward IF6D4, IF8D4, IF11D4
AT120D/FF-IV76X1 120º 25~∞mm 3.3 20.5mm
IV7635X1 ø6.2mm IF4D5/4S5, IF6C5, IF6C5X1
Steel Mesh Resin Braided “Tough Tapered Flex” tube has been AT80S-IV76X1 80º
Side
18~∞mm 4.0 24.6mm IF8C5, IF11C5 AI-4M 4 1.319 0.575
coil interior tube exterior designed to provide optimum flexibility in AT120S-IV76X1 120º 5~∞mm 5.9 24.6mm
AT40D-IV74 40º 200~∞mm 2.4 19.7mm IF6PD4, IF2D4, IF2D5 SM-R 5 1.0 1.0
aircraft engine inspection and excellent Rigid Borescopes
AT80D/NF-IV74 80º 8~∞mm 9.5 20.2mm
resistance to crushing. AT80D/FF-IV74 80º Forward 35~∞mm 3.1 20.1mm
Small Diameter Borescopes
AK-1M 6 1.8 0.31
Modelscope
AT120D/NF-IV74 120º 4~190mm 9.2 20.2mm CAMEDIA digital camera connected to
IV7440X1 ø4.4mm
AT120D/FF-IV74 120º 25~∞mm 3.3 20.1mm Olympus Industrial fiberscope via AI-DC3
Various working tools available AT80S-IV74 80º 25~∞mm 3.7 23.1mm
Versatile tools are available to meet a wide AT120S/NF-IV74 120º Side 1~20mm 9.6 23.1mm C-MOUNT ADAPTORS
range of inspection requirements such as AT120S/FF-IV74 120º 6~∞mm 6.0 23.1mm For connection of TV cameras to Fiberscopes and Rigid Borescopes.
*The rigid portion at the scope’s distal end when the adapter is mounted
retrieval of foreign objects and dropped
objects. Snare basket, 3-prong grasper,
1 2 3 4 5 6 7 8 9 10 11 12
magnet and alligator forceps are available. ■ Stereo Measurement Optical Adaptor Set Specifications
Optical System Distal End
Scope Set Name Optical Adapter Field Direction Depth F Outer Rigid distal
of view of view of field No. diameter end length*
Belt holder for hands-free operation CAMEDIA digital camera connected to
MAJ~1241D AT60D/60D-IV76X1 60º Forward 5~∞mm 26.7mm
IV7635X1 7.5 ø6.2mm Olympus Industrial borescope via AK-DC3
The remote control with channel port MAJ~1241S AT60S/60S-IV76X1 60º Side 4~∞mm 32.4mm
mounted can be attached to a belt around MAJ~1244D AT60D/60D-IV74 60º Forward 5~∞mm 26.3mm
IV7440X1 7.5 ø4.4mm ■ Specifications
MAJ~1244S AT50S/50S-IV74 50º Side 4~∞mm 30.7mm
your waist. This allows you to operate the AI-DC3 AK-DC3 Scope C-Mount adaptor Magnification ratio Brightness ratio
scope without having to hold the remote IF4D5/4S5 Series 5 industrial rigid borescopes
IF3 Series MC-04 0.8 1.6
control, and leaves your hands totally free K12/17/27 (mini borescopes)
■ IPLEX SX Operating Environment IF5D4X1 IF7D3X3-26, 32 MC-05 1 1.0 1.0
X009/X012/X017/X025 (small diameter borescopes) IF13D3-60, IF8D3X2-23 MC-08 1.6 0.39
for other tasks when you’re not operating ● Operating temperature: Insertion tube: In air: -25~80ºC* Compatible scope
IF6C5X1 IF6PD4
2
Image Carriers MC-10 3 2.0 0.25
the remote control. Under water: 10~30ºC (IV7440X1 only)
IF8C5 IF2D5 AI-10C 0.8 1.56
Other parts than above: In air: 0~40ºC IF4D4/4S4, IF5D4X1 4
IF11C5 IF8D4X2/X3
● Operating atmospheric pressure: Insertion tube: In air: 1013hPa (1atm) IF6D4, IF8D4, IF11D4 AI-11C 5 1.0 1.0
In water: 1013~1418hPa (1~1.96atm) (IV7440X1 only) Connection with camera Screwed into tripod socket of camera*
Portable package design Other parts than above: In air:1013hPa (1atm) C-2000ZOOM/C-2020ZOOM/C-3030ZOOM/C-3100ZOOM/
IF4D5/4S5, IF6C5, IF6C5X1
IF8C5, IF11C5
AI-12C 6 1.51 0.44
Compatible camera AI-3C 7 2.0 0.25
● Liquid resistance: Insertion tube, channel port, remote control: C-4040ZOOM/C-4100ZOOM/C-3020ZOOM/C-4000ZOOM/C-5050ZOOM
An integrated all-in-one design offers Two components: stay-provided mount for scope eyepiece and AK2-3C 0.45 –
Machine oil, light oil and 5% saline is attached. Construction
superior portability and faster, more ● Other parts than above: The SX case outer finish is resistant to machine oil, light oil and 5% intermediate ring for camera filter thread. AK2-4C 0.6 –
IF6PD4, IF2D4, IF2D5 AK2-5C 0.75 1.8
efficient set-up and takedown. Removing saline is attached. Note: When the adaptor is connected to the fiberscope, interference between the fiberoptic matrix and Rigid Borescopes
8
● the LCD pixels may cause striped patterns (moiré). AK2-10C 9 1.0 1.0
the control unit from the case allows you to Waterproof: Insertion tube: Can be used under water (IV7440X1 only). Small Diameter Borescopes
Drip-proof: Remote control, LCD monitor, channel port: To prevent moiré, set the camera’s focus to manual mode. AK2-20C 10 1.35 0.55
carry the IPLEX SX on your shoulder, Modelscope
Can be used in rain but cannot be used under water. * When the adaptor is connected to the camera, the camera’s tripod socket cannot be used. MC-R44 11 1.85 0.3
enhancing mobility in confined spaces and Other parts than above: Neither waterproof nor drip-proof.
To secure the camera on a tripod, use the optional fiberscope holder (MB-936/MB-937) or borescope
MC-R58 12 2.4 0.17
tripod mount (KN-29).
elevated locations. * Angulation may be affected by extreme temperatures.
06 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 19
Pipe & Visual Inspection Systems Industrial Videoscopes
IV5C6X1-15
IV6C6-13
IV6C6-20
IV6C6-35
IV6C6-50
IV6C6-75
IV8C6-20
IV8C6-35
IV8C6-50
IV8C6-75
Distal end Diameter ø5.1mm ø6.0mm ø8.4mm
D40N (NTSC)/D40P (PAL) Bending Angualtion 150º up/down MAJ-456 Rigid Sleeve
INFRA-RED TELESCOPIC CAMERA SYSTEM section
Flexibility
range direction
150º in up/down and right/left directions
1,340mm
2,040mm
3,540mm
5,030mm
7,530mm
2,010mm
3,510mm
5,000mm
7,500mm
Illumination system White LED illumination
Camera optical
Automatic adjustment by means of AGC and electric
mounted on a telescopic arm, together with a compact monitor and Working length 1,500mm
system Brightness adjustment system
shutter battery module. The complete system is supplied in a single rugged
Distal end: ø18mm
Outer diameter
Flexible portion (camera cable): ø9.0mm carrying case.
Insertion tube ■ IV5C6 Optical Adaptor Specifications The IV5C6 has short rigid section at the distal end,
Working length 40m ● Up to 12 metres viewing distance in darkness. for PT-6 inspection
Minimum bending radius R120mm Optical system Distal end
● Up to 2 hours battery life in continuous use.
Frame 480(W) x 480 (H) x 350(D) mm Field of Direction of Depth of field F No Outer Rigid distal
● High resolution monochrome monitor. view view diameter end length
m
Video signal NTSC, PAL 2 lines (RCA, BNC)
.9m
Cable drum
● Robust carrying case. Forward
26
Power supply 12V DC (operating voltage range:10.8~13.2V DC) AT120D-IV5C6X1 120º 14~100mm 5.2 17.5mm
2.7
.5m
(integrated with 5.1mm
R1
.7
17
Maximum power consumption Approx 6W (camera & LED) AT90S-IV5C6X1 90º Slide 12~100mm 5.2 22.8mm
R6
control unit)
Output power supply 1 line 12V DC, 2A (max)
Weight 14.5Kg ■ IV6C6 Optical Adaptor Specifications
Rated input 100~240V AC (50/60Hz) IV5C6X1 IV6C6
AC adaptor Optical system Distal end
Rated output 12V DC, 2.5A
Field of Direction of Depth of field F No Outer Rigid distal
Other Provided accessories Accessory storage case, AC adaptor, view view diameter end length*1
Video cable RCA-RCA
AT40D-IV6C6 40º 330 ~∞mm 3.0 26.9mm
AT80D/NF-IV6C6 80º 10 ~∞mm 13.0 27.5mm
AT80D/NF-IV6C6 80º Forward 34 ~∞mm 4.5 27.4mm
■ IV7D6X1/IV7D6X2 Scope Specifications
■ Camera Head for PT400 Specifications Field of view 120º
AT120D/NF-IV6C6 120º 5 ~∞mm 12.5 27.0mm Optical
D23N (NTSC) D23P D40N (NTSC)
(PAL) D40P (PAL)
AT120D/FF-IV6C6 120º 20 ~∞mm 5.5 26.9mm system Direction of view Forward viewing
Field of view 80º 100º ø6.0mm
Optical system Direction of view Forward AT80S-IV6C6 80º 23~200mm 5.0 32.3mm Depth of field 9 to 80mm
Depth of field 20mm~∞mm (adjustable focus) AT120S/NF-IV6C6 120º Side 1~9mm 15.5 32.3mm Outer diameter ø7.3mm
Distal end
Distal end Outer diameter 23mm 40mm AT120S/FF-IV6C6 120º 7~90mm 8.0 32.3mm Rigid distal end length 19.8mm
AT60D/60D-IV6C6*2 60º/60º Direct/Direct 7~30mm 9.3 38mm Insertion Bending section Angulation range 130º in up/down and right/left directions
● Operating temperature: Insertion tube: In air: 0~40ºC tube
AT60S/60S-IV6C6*2 60º/60º Side/Side 6~30mm 9.3 44mm Flexible portion (tube) Flexibility Tapered Flex Tube
● Operating pressure: In air: 1013hPa
Outer diameter ø7.3mm
In water: 1013~1114hPa ■ IV8C6 Optical Adaptor Specifications Working length 2,610mm
● Waterproof properties: Watertight design, waterproof structure (3m depth of water)
Corrosion of heat exchanger end plate Optical system Distal end Channel Inner diameter ø1.7mm
Field of Direction of Depth of field F No Outer Rigid distal Universal cord length 2,000mm
view view diameter end length*1
150 x 46 x 28mm (compact version) including illuminator
Size AT40D-IV8C6 40º 200 ~∞mm 2.5 26.2mm
230 x 46 x 28mm (standard version) including illuminator
AT80D-IV8C6 80º 40 ~∞mm 5.5 29.4mm
Custom Packaging Viewing head
Camera
Sensitivity
Monochrome, 380 x 420 lines resolution
0.2 lux at fl.2
Infrared LED array - 850nm (compact version)
AT120D/NF-IV8C6
AT120D/FF-IV8C6
120º
120º
Forward
5 ~∞mm 14.0
45 ~∞mm 3.0
29.6mm
29.3mm
■ MAJ-456 Rigid Sleeve Specifications
Field of view 120º
Illumination ø8.4mm Optical system Direction of view Side view
- 950nm (standard convert version) AT80S-IV8C6 80º 22 ~∞mm 6.0 36.4mm
Side Depth of field 7~80mm
Power 12V DC, supplied by battery within chest pouch AT120S-IV8C6 120º 3 ~55mm 16.0 35.8mm
Packaging Type Lightweight, telescopic AT120D/120S-IV8C6 120º/120º Forward/Side 5~∞mm/3~∞mm 5/9 28.0mm Insertion tube
Outer diameter ø8mm
AT60D/60D-IV8C6*2 60º/60º Forward/Forward 5~50mm/5~50mm 11/11 24.0mm Working length 338mm
Packaging has always been a very important part of the Olympus Telescopic Pole Length 435 - 1530mm (extended)
Weight 0.5kg (including camera head/ illuminator) *1 When the Adaptor is attached to the scope. Total length 420mm
product range. We have therefore standardised our packaging to suit *2 For 3D measurement.
Type Monochrome - CRT
various customer needs including dedicated customised packaging for Monitor Size 120 x 230 x 60mm with 4" screen
system configurations. Resolution 420 lines Series 6 systems can be conveniently ■ Operating Environment for Series 6 Videoscopes
Olympus can offer a variety of hardcase and softbag solutions. Type 12V 2.5Ah Cyclon, sealed lead acid packaged (see page 18 for details). ● Operating temperature: Insertion tube: In air: -10~80ºC (14~176ºF)*
Minimum: 2 hours continuous use (compact version) All systems require a control unit and In water: 10~30ºC (50~86ºF)**
Battery Run Time
1 hours continuous use (standard version) All portions except insertion tube: In air: 0~40ºC (32~104ºF)
Charge Time 2 hours provides 95% capacity, full charge approx 8 hours
can be used with digital image storage ● Operating pressure: Insertion tube:
Type Constant voltage devices (see page 8). In air: 1013hPa (normal pressure) (IV6C6/8C6)
Battery Charger Input 198 - 264V AC, 50Hz or 100 - 110V AC, 60Hz In water: 1013 (normal pressure)~1360hPa (1~1.35atm) (IV6C6/8C6-13,20,35)
Output 14.4V DC max, 2.2A 1013 (normal pressure)~1773hPa (1~1.75atm) (IV6C6/8C6-50,75)
Chest Pouch Padded nylon with sun shield. Neck and waist straps with quick release buckles All portions except insertion tube: In air: 1013hPa (1atm normal pressure)
Double skinned, toughtened ABS. Waterproof, with O ring seal and pressure ● Liquid resistance: Insertion tube: Withstands machine oil, light oil and 5% salt water
Carrying Case (10~30ºC or 50~86ºF) (normal temperature).
relief valve.
Telescopic pole with camera head/ illumination, control unit, 4" monochrome monitor, * At 50~80ºC atmosphere, use the instrument at a relative humidity of 40% or below. Using the instrument at a higher
Standard Set
1 x battery pack, battery charger, chest pouch, carrying case and instructions. humidity may cause equipment damage.
** Insertion tube of IV7D6 and IV5C6X1 scopes is splashproof, except for the channel of IV7D6, which is not fluid-proof.
Accessories Protective cover for camera head. Wrist strap.
18 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 07
Industrial Videoscopes Light Sources
SERIES 5
6 VIDEOSCOPES CONTROL UNIT FOR SERIES 6 & SERIES 5 VIDEOSCOPES TUNGSTEN HALOGEN LIGHT SOURCES LIGHT SOURCE
INDUSTRIAL VIDEOSCOPE
INDUSTRIAL VIDEOSCOPE CONTROL UNIT ILK-7/ILK-7A/ILK-7B KLS-131
IV6C5-110/160 IV-6A The ILK-7 range of light sources incorporates a 150W tungsten-halogen The KLS-131 light source can be used as a stand alone system or as
Loaded with every imaginable leading edge RVI function, the IV-6A is designed to lamp offering features necessary to meet most industrial needs. part of the modular borescope system. It is available with either XLR
The IV6C5 Series offers working lengths of up to 16 metres. make your inspections as efficient and effective as possible. SPECIFICATIONS connector or crocodile clips for car battery use.
● Remote control operation using the Series 6 scope’s “Five Button” control pad. Lamp: 150W tungsten-halogen SPECIFICATIONS
RADIATION RESISTANT VIDEOSCOPES ● Extended exposure time for darker areas. Weight: 2.3kg Lamp: 50W tungsten-halogen
● Automatic brightness adjustment.
IV6C5X1-75/110 ● Zooming and virtual scrolling (panning) with moving images.
Dimensions: 178 x 230 x 76mm Weight: 0.6kg
Power Supply: ILK-7 – 100-120V 50-60Hz, 115V 400Hz Dimensions: 137 x 53mm
The IV6C5X1 Series scopes are radiation-resistant up to ● Built-in image enhancement function.
● Compatible with Series 5 scopes when MAJ-565 adaptor is used. ILK-7A – 100-240V 50-60Hz, 115V 400Hz 12VDC Power Supply 12VDC
50Gy (5000 Rad).
● Compatible with fiberscopes and borescopes when OTC-6 C-Mount CCD ILK-7B – 100-240V 50-60Hz, 115V 400Hz Power Consumption: 80W
Camera is used (see below). Power Consumption: 190W max
SPECIFICATIONS
Voltage: 12V DC
Power Consumption:
24W maximum
Dimensions:
174(W) x 259(H) x 2241(D) mm
Weight: 1.5Kg
HIGH INTENSITY LIGHT SOURCES Slim diameters, superior optics and maximum flexibility for
ILH-2A/ILH-2B
The ILH-2A and ILH-2B light sources have a custom designed high ultimate control in industrial inspection
output 50W metal halide arc lamp. This produces nearly x 3 the output
of the ILK-7. The unit is small in size and as well as being used with
borescopes and fiberscopes, can be installed into the System Case 2 or
used separately
Both the ILH-2A and ILH-2B have two hirose power outputs offering a STRUCTURAL DRAWING
12VDC 2 amp total for operation of Olympus ancillary equipment.
SPECIFICATIONS
Lamp: 50W Metal Halide
Weight: 3kg
Dimensions: 173 x 235 x 85mm
Power Supply: ILH-2A – 110-230V 50-60Hz, 115V 400Hz Field of view
ILH-2B – 110-230V 50-60Hz, 115V 400Hz
(with AC Adaptor) 12VDC
Power Consumption: 100W max
COLOUR TEMPERATURE
.6
The colour temperature of a lamp is an indication of its radiance and is
measured in degrees absolute (°K in SI units). 500nm
Tip angulation
.5 The distal end can be moved in either two or four directions, by hand-
Typically, tungsten-halogen lamps have a colour temperature of 3,200°K,
held controls (all models except 0.6mm diameter).
whilst metal-halide and UHP arc lamps are around 5,600°K. The colour
temperature of the sun is 5,900°K. .4
Interchangeable optical adaptors
TUNGSTEN HALOGEN X 600nm
Facilitate a wide variety of viewing angles and directions in just one
With tungsten-halogen lamps, the colour temperature can be reduced by
METAL HALIDE XX SUN scope (most models).
decreasing the voltage across the lamp filament. Some light sources use .3 X UHP
this method to adjust the ‘intensity’ of the light output. Unfortunately, this 490nm 700nm Fully waterproof insertion section
‘rheostat’ type control increases the ‘yellowing’ of the resultant illumination. Photo and video documentation
.2
For this reason, all Olympus light sources use a mechanical shutter to
control light output, as the full colour temperature of the lamp is preserved.
480nm
.1
POWER
470nm
∞
200000K
100000K
65000K
4800 K
36000K
28540K
23600K
19000K
15000K
10000K
.0 450nm
0
Y
metal-halide or UHP lamp will produce a higher illumination level (in X .0 .1 .2 .3 .4 .5 .6 .7 .8
output per unit area) than a 500W tungsten-halogen lamp.
16 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 09
Industrial Fiberscopes Industrial Rigid Borescopes
Optical system
Direction of view Direct/side viewing (convertible using optical adaptor) front panel buttons. All connections, including power for the Digital T086-030-110-50 8.8mm 305mm Retro (110°) 50° 9 to 100mm
Depth of field See optical adaptor specifications (fixed focus) Measuring Borescope, are direct to the controller making set-up quick T100-010-000-50 10.1mm 104mm Direct (000°) 50° 9 to 130mm
Illumination system Light guide system T100-020-000-50 10.1mm 204mm Direct (000°) 50° 9 to 120mm
and easy.
Outer diameter ø11.3mm T100-030-000-50 10.1mm 305mm Direct (000°) 50° 9 to 100mm
Distal end T100-010-090-50 10.2mm 106mm Lateral (090°) 50° 9 to 130mm
Distal end length 25.5mm The DMBC provides four
Bending section Angulation range Up 120º, Down 120º, Right 100º, Left 100º modes of measurement T100-020-090-50 10.2mm 204mm Lateral (090°) 50° 9 to 120mm
Insertion tube Outer diameter ø11.3mm (TF tube) T100-030-090-50 10.2mm 305mm Lateral (090°) 50° 9 to 100mm
including point-to-point linear,
Working length 1000mm 2000mm 3000mm
point to line, depth and 2D ■ Modular Borescope - Mirror Sheath Specifications
Total length 1250mm 2250mm 3250mm
Light guide cable length 2000mm
scaling. This covers the majority Maximum Working Direction of Field of Minimum working
of measurements for turbine Model diameter length view view length
■ IF11C5 Optical Adaptor Specifications applications such as crack MT086-010-090 8.7mm 105mm Lateral (090°) As probe 0 to 121mm
Field of view Direction of view Depth of field length, leading edge, MT086-020-090 8.7mm 207mm Lateral (090°) As probe 0 to 108mm
Provided AT60D/FF-IF11C5 60º Direct viewing 27~ 390mm MT086-030-090 8.7mm 306mm Lateral (090°) As probe 0 to 91mm
displacement, tip loss, FOD
AT30D/NF-IF11C5 30º 38~ 70mm MT110-010-090 11.2mm 106mm Lateral (090°) As probe 0 to 118mm
AT30D/FF-IF11C5 30º 65~ 120mm
depth and blade separation.
MT110-020-090 11.2mm 207mm Lateral (090°) As probe 0 to 108mm
AT60D/NF-IF11C5 60º Direct viewing 11~ 45mm MT110-030-090 11.2mm 306mm Lateral (090°) As probe 0 to 91mm
AT100D/NF-IF11C5 100º 5~ 40mm
AT100D/FF-IF11C5 100º 16~ 300mm
Optional ■ Digital Measuring Borescope System Specifications ■ Light Source Specifications
AT30S-IF11C5 30º 55~ 100mm
AT60S/NF-IF11C5 60º 11~ 40mm Outer diameter ø8.1mm Power Power Light output
Model Lamp Weight Dimensions supply consumption control
AT60S/FF-IF11C5 60º Side viewing 28~ 440mm
AT100S/NF-IF11C5 100º 3~ 22mm Working length 246mm, 446mm
50W
AT100S/FF-IF11C5 100º 12~ 250mm Insertion tube Direction of view 50º~110º Miniature 137mm long x Constant-colour
12V DC
Field of view 20º KLS-131 quartz 0.5kg 53mm diameter 55W temperature
±10%
■ IF6C5X1/IF8C5/IF11C5 Operating Environment halogen, (approx) variable shutter
● Operating temperature: Insertion tube: In air: -10~80ºC (14~176ºF) Measurement range 10~180mm 12V
In water: 10~30ºC (50~86ºF) ±4% (10-60mm Measurement range)
All portions except insertion tube: In air: 10~50ºC (14~122ºF) Measurement Accuracy
±8% (60-180mm Measurement range)
● Operating pressure: Insertion tube: In air/water: 1013~1317hPa (1~1.3atm) ■ Modular Borescope
All portions except insertion tube: In air: 1013hPa (1atm) ● Operating temperature: Probe/mirror sheath: –10 to +150°C (+14 to +302°F)
● Drip-proof control section for durable performance in adverse conditions. ● Operating temperature: Insertion tube: In air: -20~150ºC (-4~302ºF) Other parts: –10 to +40°C (+14 to +104°F)
● Fully waterproof insertion section for underwater use (corrosion-protected against machine oil, All portions except insertion tube: In air: 0~50ºC (32~122ºF) ● Operating pressure: Probe: In air: 0.7 to 1.7 bar (10.3 to 25 lbf/in2)
kerosene and 5% saline). ● Operating pressure: In air: 709~1722hPa (0.7~1.7atm) In water: 1.0 to 1.7 bar (14.7 to 25 lbf/in2)
In water: Up to 1722hPa (1.7atm) ● Fluid resistance: Probe and mirror sheath can be immersed for short periods in 5%
Note: As with any fiberscope, due to normal product characteristics all models may show a small ● Liquid resistance (insertion tube): Withstands aviation fuels, machine oil, light oil and 5% salt water, petrol, diesel, engine oil, brake fluid, ethylene glycol and
number of broken fibres. The angulation angle decreases as the scope is coiled. salt water (normal pressure). methanol (at +10ºC to +30°C, and atmospheric pressure)
10 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 15
Industrial Rigid Borescopes Industrial Fiberscopes
■ Small Diameter Borescope Specifications - X Series ● Operating temperature: Insertion tube: In air: -6~66ºC (21~150ºF)
All portions except insertion tube: -6~50ºC (21~122ºF)
Outer Working Field of
diameter length Direction of view view Depth of field ● Operating pressure: In air: 1013hPa (1atm)
Direct: 3 to infinity
ø0.9mm
60mm or
150mm
Direct (0º) or
Forward-oblique (15º)
70º INDUSTRIAL FIBERSCOPE
Forward-oblique: 2 to 7
14 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 11
Industrial Rigid Borescopes Industrial Rigid Borescopes
STRUCTURAL DRAWING Rigid borescopes are used where there is straight line
access to the inspection area. They provide cost Borescope R120 - 039 - 090 - 35 ILG
effective solutions for applicatons as diverse as
maintenance, quality control, research, development : Series 5 Borescope : Direction of view degrees (eg 90º lateral)
and security. : Diameter 0.1mm (eg 12mm) : Field of view degrees (eg 35º)
: Working length cm (eg 39cm) : Integral light guide (12 & 16mm diameter only)
The Series 5 product design provides:
● Large, bright, clear, high-resolution images
● A wide range of robust, versatile instruments R040-021-000-60 R080-104-045-50 R100-067-045-50
● A fully integrated system R040-033-000-60 R080-124-045-50 R100-095-045-50
To satisfy customer and application requirements, the Olympus Series R040-022-045-60 R080-144-045-50 R100-025-090-35
R040-033-045-60 R080-024-090-50 R100-025-090-50
5 range also includes:
R040-022-090-60 R080-025-090-35 R100-029-090-10
● Series 5 Swing Prism Borescope R040-033-090-60 R080-028-090-10 R100-039-090-50
● Series 5 Zoom Swing Prism Borescope R080-034-090-50 R100-039-090-35
● Series 5 Engine Borescope R060-017-000-50 R080-035-090-35 R100-043-090-10
Unbeatable relay lens optics for sharp image R060-032-000-50 R080-044-090-50 R100-053-090-50
transmission with light guide fibres for bright illumination.
STANDARD SERIES 5 BORESCOPE R060-047-000-50 R080-045-090-35 R100-053-090-35
The Series 5 standard range is available in a choice of seven diameters R060-063-000-50 R080-048-090-10 R100-057-090-10
Wide selection available to suit any requirements. from 4-16mm. The standard range also offers varying lengths and R060-017-045-50 R080-054-090-50 R100-067-090-50
R060-032-045-50 R080-064-090-50 R100-067-090-35
Incorporating a multiple-element relay lens system in a durable stainless direction of view and field of view.
R060-047-045-50 R080-065-090-35 R100-081-090-35
steel insertion tube, Series 5 industrial rigid borescopes deliver superb R060-063-045-50 R080-074-090-50 R100-095-090-50
high-resolution images. Detachable light guide fibres transmit R060-017-090-50 R080-084-090-50 R100-095-090-35
illumination from a separate light source directly to the site. R060-032-090-50 R080-104-090-50 R100-099-110-50
R060-047-090-50 R080-124-090-50 R100-095-110-50
MAIN APPLICATIONS R060-063-090-50 R080-144-090-50
R060-078-090-50 R080-024-110-50 R120-039-090-35 ILG
Ideal for internal inspection of sites that can be R080-034-110-50 R120-053-090-35 ILG
accessed head-on with relatively shallow insertion. R080-024-000-50 R080-044-110-50
Excellent images are delivered by eye or when a TV R080-044-000-50 R080-054-110-50 R160-059-000-35 ILG
R080-064-000-50 R080-064-110-50 R160-101-000-35 ILG
camera is attached. SERIES 5 SWING PRISM BORESCOPE R080-084-000-50 R080-094-110-50 R160-143-000-35 ILG
For inspecting: R080-124-000-50 R080-104-110-50 R160-059-090-35 ILG
The Series 5 swing prism borescope has been designed to allow the R080-144-000-50 R080-124-110-50 R160-101-090-35 ILG
● Inside narrow-diameter holes and pipes. operator to scan a large area, saving time and expense. The direction of R080-024-045-50 R160-122-090-35 ILG
● Inside cast and hydraulic parts and honing-processed holes. viewing can be adjusted continuously between 45º to 115º, coupled with R080-044-045-50 R100-038-000-50 R160-143-090-35 ILG
● Inside aircraft engines, hollow walls or buildings, machinery, a field of view, this allows a total viewing arc of 120º to 140º. The Series R080-064-045-50 R100-066-000-50
structures etc. 5 Swing borescope is available in both 6mm and 8mm diameters. R080-084-045-50 R100-039-045-50
MAIN FEATURES
Ideal for TV monitor inspection Borescope R080 - 044 - 045SW115 - 50ZM25
Up to six times brighter images than
conventional models. : Series 5 Borescope : Direction of view degrees (eg 45º to 115º)
Clear, high-resolution images : Diameter 0.1mm (eg 8mm) : Field of view degrees (eg 50º)
: Working length cm (eg 44cm) : Field of view zoom range (eg 50º to 25º)
Excellent detail reproductions. Sharp (zoom models only)
image is easy on the eyes, helping
reduce inspector fatigue.
SERIES 5 ZOOM SWING PRISM BORESCOPE ■ Swing-Prism and Zoom Swing-Prism Specifications
Focus adjustment mechanism The Series 5 Zoom swing prism borescope has been added to the R060-023-045SW115-50 R080-043-045SW115-50
Easy to use focus control. successful swing prism range. It incorporates the same characteristics R060-031-045SW115-50 R080-044-045SW115-20
370º orbital scan as the standard swing prism, but with the added feature of 2 x optical R060-046-045SW115-50 R080-053-045SW115-50
zoom. This allows the user to zoom onto an object of interest, providing R060-077-045SW115-50 R080-063-045SW115-50
Upward pointer keeps you oriented when using R060-024-045SW115-50ZM25 R080-064-045SW115-20
the rotation function (except direct viewing a magnified view.
R060-032-045SW115-50ZM25 R080-083-045SW115-50
scopes and R160 models). R060-047-045SW115-50ZM25 R080-103-045SW115-50
Increased field of view R060-062-045SW115-50ZM25 R080-024-045SW115-50ZM25
R080-034-045SW115-50ZM25
32% larger field of view in 4mm ø models and R080-023-045SW115-50 R080-044-045SW115-50ZM25
96% larger field of view in 6mm ø models. R080-024-045SW115-20 R080-054-045SW115-50ZM25
Accurate image reproduction R080-033-045SW115-50 R080-064-045SW115-50ZM25
Distortion at image edges has been dramatically reduced.
■ Aero-engine Model Specifications
Even illumination
Instrument Engine Instrument Engine
New tip design ensures more even illumination even when viewing
close-range subjects. SERIES 5 ENGINE BORESCOPES R055-047-000-55 Pegasus R080-034-110-55 TRENT
The Series 5 engine borescope has been designed to meet R055-047-090-55 Pegasus/RB199 R100-017-090-35 TRENT
Outstanding durability manufacturer and user specification requirements specifically for a R055-085-090-55 Pegasus R100-024-090-35V CFM-56
Stainless steel insertion tube usable at temperatures between -20ºC and number of key military and commercial aero engines. R060-047-090-55 M88 RE080-012-090-60 CFM-56
150ºC as well as under pressure of up to 1.7 atmospheres. R060-047-060-30 M88 RE080-029-060-60 CFM-56
R060-032-070-40GI MTR-390 RE080-029-110-60 CFM-56
Ergonomic control section R055-017-090-60 MTR-390 RE100-041-090-35V GE-90
Extremely comfortable and functional. R080-025-110-35GI RTM-322 RE100-068-090-55 GE-90
R060-024-070-60 RTM-322 RE080-043-060-55 GE-90
Comprehensive range R080-024-060-50 RTM-322 RE080-043-110-55 GE-90
Almost 200 models available featuring various R080-041-070-60 TRENT
diameters, working lengths and viewing
directions and angles. Note: Many aero-engine inspections use standard or swing-prism borescopes. Contact our application
specialists for specific advice.
12 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 13
Industrial Rigid Borescopes Industrial Rigid Borescopes
STRUCTURAL DRAWING Rigid borescopes are used where there is straight line
access to the inspection area. They provide cost Borescope R120 - 039 - 090 - 35 ILG
effective solutions for applicatons as diverse as
maintenance, quality control, research, development : Series 5 Borescope : Direction of view degrees (eg 90º lateral)
and security. : Diameter 0.1mm (eg 12mm) : Field of view degrees (eg 35º)
: Working length cm (eg 39cm) : Integral light guide (12 & 16mm diameter only)
The Series 5 product design provides:
● Large, bright, clear, high-resolution images
● A wide range of robust, versatile instruments R040-021-000-60 R080-104-045-50 R100-067-045-50
● A fully integrated system R040-033-000-60 R080-124-045-50 R100-095-045-50
To satisfy customer and application requirements, the Olympus Series R040-022-045-60 R080-144-045-50 R100-025-090-35
R040-033-045-60 R080-024-090-50 R100-025-090-50
5 range also includes:
R040-022-090-60 R080-025-090-35 R100-029-090-10
● Series 5 Swing Prism Borescope R040-033-090-60 R080-028-090-10 R100-039-090-50
● Series 5 Zoom Swing Prism Borescope R080-034-090-50 R100-039-090-35
● Series 5 Engine Borescope R060-017-000-50 R080-035-090-35 R100-043-090-10
Unbeatable relay lens optics for sharp image R060-032-000-50 R080-044-090-50 R100-053-090-50
transmission with light guide fibres for bright illumination.
STANDARD SERIES 5 BORESCOPE R060-047-000-50 R080-045-090-35 R100-053-090-35
The Series 5 standard range is available in a choice of seven diameters R060-063-000-50 R080-048-090-10 R100-057-090-10
Wide selection available to suit any requirements. from 4-16mm. The standard range also offers varying lengths and R060-017-045-50 R080-054-090-50 R100-067-090-50
R060-032-045-50 R080-064-090-50 R100-067-090-35
Incorporating a multiple-element relay lens system in a durable stainless direction of view and field of view.
R060-047-045-50 R080-065-090-35 R100-081-090-35
steel insertion tube, Series 5 industrial rigid borescopes deliver superb R060-063-045-50 R080-074-090-50 R100-095-090-50
high-resolution images. Detachable light guide fibres transmit R060-017-090-50 R080-084-090-50 R100-095-090-35
illumination from a separate light source directly to the site. R060-032-090-50 R080-104-090-50 R100-099-110-50
R060-047-090-50 R080-124-090-50 R100-095-110-50
MAIN APPLICATIONS R060-063-090-50 R080-144-090-50
R060-078-090-50 R080-024-110-50 R120-039-090-35 ILG
Ideal for internal inspection of sites that can be R080-034-110-50 R120-053-090-35 ILG
accessed head-on with relatively shallow insertion. R080-024-000-50 R080-044-110-50
Excellent images are delivered by eye or when a TV R080-044-000-50 R080-054-110-50 R160-059-000-35 ILG
R080-064-000-50 R080-064-110-50 R160-101-000-35 ILG
camera is attached. SERIES 5 SWING PRISM BORESCOPE R080-084-000-50 R080-094-110-50 R160-143-000-35 ILG
For inspecting: R080-124-000-50 R080-104-110-50 R160-059-090-35 ILG
The Series 5 swing prism borescope has been designed to allow the R080-144-000-50 R080-124-110-50 R160-101-090-35 ILG
● Inside narrow-diameter holes and pipes. operator to scan a large area, saving time and expense. The direction of R080-024-045-50 R160-122-090-35 ILG
● Inside cast and hydraulic parts and honing-processed holes. viewing can be adjusted continuously between 45º to 115º, coupled with R080-044-045-50 R100-038-000-50 R160-143-090-35 ILG
● Inside aircraft engines, hollow walls or buildings, machinery, a field of view, this allows a total viewing arc of 120º to 140º. The Series R080-064-045-50 R100-066-000-50
structures etc. 5 Swing borescope is available in both 6mm and 8mm diameters. R080-084-045-50 R100-039-045-50
MAIN FEATURES
Ideal for TV monitor inspection Borescope R080 - 044 - 045SW115 - 50ZM25
Up to six times brighter images than
conventional models. : Series 5 Borescope : Direction of view degrees (eg 45º to 115º)
Clear, high-resolution images : Diameter 0.1mm (eg 8mm) : Field of view degrees (eg 50º)
: Working length cm (eg 44cm) : Field of view zoom range (eg 50º to 25º)
Excellent detail reproductions. Sharp (zoom models only)
image is easy on the eyes, helping
reduce inspector fatigue.
SERIES 5 ZOOM SWING PRISM BORESCOPE ■ Swing-Prism and Zoom Swing-Prism Specifications
Focus adjustment mechanism The Series 5 Zoom swing prism borescope has been added to the R060-023-045SW115-50 R080-043-045SW115-50
Easy to use focus control. successful swing prism range. It incorporates the same characteristics R060-031-045SW115-50 R080-044-045SW115-20
370º orbital scan as the standard swing prism, but with the added feature of 2 x optical R060-046-045SW115-50 R080-053-045SW115-50
zoom. This allows the user to zoom onto an object of interest, providing R060-077-045SW115-50 R080-063-045SW115-50
Upward pointer keeps you oriented when using R060-024-045SW115-50ZM25 R080-064-045SW115-20
the rotation function (except direct viewing a magnified view.
R060-032-045SW115-50ZM25 R080-083-045SW115-50
scopes and R160 models). R060-047-045SW115-50ZM25 R080-103-045SW115-50
Increased field of view R060-062-045SW115-50ZM25 R080-024-045SW115-50ZM25
R080-034-045SW115-50ZM25
32% larger field of view in 4mm ø models and R080-023-045SW115-50 R080-044-045SW115-50ZM25
96% larger field of view in 6mm ø models. R080-024-045SW115-20 R080-054-045SW115-50ZM25
Accurate image reproduction R080-033-045SW115-50 R080-064-045SW115-50ZM25
Distortion at image edges has been dramatically reduced.
■ Aero-engine Model Specifications
Even illumination
Instrument Engine Instrument Engine
New tip design ensures more even illumination even when viewing
close-range subjects. SERIES 5 ENGINE BORESCOPES R055-047-000-55 Pegasus R080-034-110-55 TRENT
The Series 5 engine borescope has been designed to meet R055-047-090-55 Pegasus/RB199 R100-017-090-35 TRENT
Outstanding durability manufacturer and user specification requirements specifically for a R055-085-090-55 Pegasus R100-024-090-35V CFM-56
Stainless steel insertion tube usable at temperatures between -20ºC and number of key military and commercial aero engines. R060-047-090-55 M88 RE080-012-090-60 CFM-56
150ºC as well as under pressure of up to 1.7 atmospheres. R060-047-060-30 M88 RE080-029-060-60 CFM-56
R060-032-070-40GI MTR-390 RE080-029-110-60 CFM-56
Ergonomic control section R055-017-090-60 MTR-390 RE100-041-090-35V GE-90
Extremely comfortable and functional. R080-025-110-35GI RTM-322 RE100-068-090-55 GE-90
R060-024-070-60 RTM-322 RE080-043-060-55 GE-90
Comprehensive range R080-024-060-50 RTM-322 RE080-043-110-55 GE-90
Almost 200 models available featuring various R080-041-070-60 TRENT
diameters, working lengths and viewing
directions and angles. Note: Many aero-engine inspections use standard or swing-prism borescopes. Contact our application
specialists for specific advice.
12 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 13
Industrial Rigid Borescopes Industrial Fiberscopes
■ Small Diameter Borescope Specifications - X Series ● Operating temperature: Insertion tube: In air: -6~66ºC (21~150ºF)
All portions except insertion tube: -6~50ºC (21~122ºF)
Outer Working Field of
diameter length Direction of view view Depth of field ● Operating pressure: In air: 1013hPa (1atm)
Direct: 3 to infinity
ø0.9mm
60mm or
150mm
Direct (0º) or
Forward-oblique (15º)
70º INDUSTRIAL FIBERSCOPE
Forward-oblique: 2 to 7
14 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 11
Industrial Fiberscopes Industrial Rigid Borescopes
Optical system
Direction of view Direct/side viewing (convertible using optical adaptor) front panel buttons. All connections, including power for the Digital T086-030-110-50 8.8mm 305mm Retro (110°) 50° 9 to 100mm
Depth of field See optical adaptor specifications (fixed focus) Measuring Borescope, are direct to the controller making set-up quick T100-010-000-50 10.1mm 104mm Direct (000°) 50° 9 to 130mm
Illumination system Light guide system T100-020-000-50 10.1mm 204mm Direct (000°) 50° 9 to 120mm
and easy.
Outer diameter ø11.3mm T100-030-000-50 10.1mm 305mm Direct (000°) 50° 9 to 100mm
Distal end T100-010-090-50 10.2mm 106mm Lateral (090°) 50° 9 to 130mm
Distal end length 25.5mm The DMBC provides four
Bending section Angulation range Up 120º, Down 120º, Right 100º, Left 100º modes of measurement T100-020-090-50 10.2mm 204mm Lateral (090°) 50° 9 to 120mm
Insertion tube Outer diameter ø11.3mm (TF tube) T100-030-090-50 10.2mm 305mm Lateral (090°) 50° 9 to 100mm
including point-to-point linear,
Working length 1000mm 2000mm 3000mm
point to line, depth and 2D ■ Modular Borescope - Mirror Sheath Specifications
Total length 1250mm 2250mm 3250mm
Light guide cable length 2000mm
scaling. This covers the majority Maximum Working Direction of Field of Minimum working
of measurements for turbine Model diameter length view view length
■ IF11C5 Optical Adaptor Specifications applications such as crack MT086-010-090 8.7mm 105mm Lateral (090°) As probe 0 to 121mm
Field of view Direction of view Depth of field length, leading edge, MT086-020-090 8.7mm 207mm Lateral (090°) As probe 0 to 108mm
Provided AT60D/FF-IF11C5 60º Direct viewing 27~ 390mm MT086-030-090 8.7mm 306mm Lateral (090°) As probe 0 to 91mm
displacement, tip loss, FOD
AT30D/NF-IF11C5 30º 38~ 70mm MT110-010-090 11.2mm 106mm Lateral (090°) As probe 0 to 118mm
AT30D/FF-IF11C5 30º 65~ 120mm
depth and blade separation.
MT110-020-090 11.2mm 207mm Lateral (090°) As probe 0 to 108mm
AT60D/NF-IF11C5 60º Direct viewing 11~ 45mm MT110-030-090 11.2mm 306mm Lateral (090°) As probe 0 to 91mm
AT100D/NF-IF11C5 100º 5~ 40mm
AT100D/FF-IF11C5 100º 16~ 300mm
Optional ■ Digital Measuring Borescope System Specifications ■ Light Source Specifications
AT30S-IF11C5 30º 55~ 100mm
AT60S/NF-IF11C5 60º 11~ 40mm Outer diameter ø8.1mm Power Power Light output
Model Lamp Weight Dimensions supply consumption control
AT60S/FF-IF11C5 60º Side viewing 28~ 440mm
AT100S/NF-IF11C5 100º 3~ 22mm Working length 246mm, 446mm
50W
AT100S/FF-IF11C5 100º 12~ 250mm Insertion tube Direction of view 50º~110º Miniature 137mm long x Constant-colour
12V DC
Field of view 20º KLS-131 quartz 0.5kg 53mm diameter 55W temperature
±10%
■ IF6C5X1/IF8C5/IF11C5 Operating Environment halogen, (approx) variable shutter
● Operating temperature: Insertion tube: In air: -10~80ºC (14~176ºF) Measurement range 10~180mm 12V
In water: 10~30ºC (50~86ºF) ±4% (10-60mm Measurement range)
All portions except insertion tube: In air: 10~50ºC (14~122ºF) Measurement Accuracy
±8% (60-180mm Measurement range)
● Operating pressure: Insertion tube: In air/water: 1013~1317hPa (1~1.3atm) ■ Modular Borescope
All portions except insertion tube: In air: 1013hPa (1atm) ● Operating temperature: Probe/mirror sheath: –10 to +150°C (+14 to +302°F)
● Drip-proof control section for durable performance in adverse conditions. ● Operating temperature: Insertion tube: In air: -20~150ºC (-4~302ºF) Other parts: –10 to +40°C (+14 to +104°F)
● Fully waterproof insertion section for underwater use (corrosion-protected against machine oil, All portions except insertion tube: In air: 0~50ºC (32~122ºF) ● Operating pressure: Probe: In air: 0.7 to 1.7 bar (10.3 to 25 lbf/in2)
kerosene and 5% saline). ● Operating pressure: In air: 709~1722hPa (0.7~1.7atm) In water: 1.0 to 1.7 bar (14.7 to 25 lbf/in2)
In water: Up to 1722hPa (1.7atm) ● Fluid resistance: Probe and mirror sheath can be immersed for short periods in 5%
Note: As with any fiberscope, due to normal product characteristics all models may show a small ● Liquid resistance (insertion tube): Withstands aviation fuels, machine oil, light oil and 5% salt water, petrol, diesel, engine oil, brake fluid, ethylene glycol and
number of broken fibres. The angulation angle decreases as the scope is coiled. salt water (normal pressure). methanol (at +10ºC to +30°C, and atmospheric pressure)
10 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 15
Light Sources Industrial Fiberscopes
HIGH INTENSITY LIGHT SOURCES Slim diameters, superior optics and maximum flexibility for
ILH-2A/ILH-2B
The ILH-2A and ILH-2B light sources have a custom designed high ultimate control in industrial inspection
output 50W metal halide arc lamp. This produces nearly x 3 the output
of the ILK-7. The unit is small in size and as well as being used with
borescopes and fiberscopes, can be installed into the System Case 2 or
used separately
Both the ILH-2A and ILH-2B have two hirose power outputs offering a STRUCTURAL DRAWING
12VDC 2 amp total for operation of Olympus ancillary equipment.
SPECIFICATIONS
Lamp: 50W Metal Halide
Weight: 3kg
Dimensions: 173 x 235 x 85mm
Power Supply: ILH-2A – 110-230V 50-60Hz, 115V 400Hz Field of view
ILH-2B – 110-230V 50-60Hz, 115V 400Hz
(with AC Adaptor) 12VDC
Power Consumption: 100W max
COLOUR TEMPERATURE
.6
The colour temperature of a lamp is an indication of its radiance and is
measured in degrees absolute (°K in SI units). 500nm
Tip angulation
.5 The distal end can be moved in either two or four directions, by hand-
Typically, tungsten-halogen lamps have a colour temperature of 3,200°K,
held controls (all models except 0.6mm diameter).
whilst metal-halide and UHP arc lamps are around 5,600°K. The colour
temperature of the sun is 5,900°K. .4
Interchangeable optical adaptors
TUNGSTEN HALOGEN X 600nm
Facilitate a wide variety of viewing angles and directions in just one
With tungsten-halogen lamps, the colour temperature can be reduced by
METAL HALIDE XX SUN scope (most models).
decreasing the voltage across the lamp filament. Some light sources use .3 X UHP
this method to adjust the ‘intensity’ of the light output. Unfortunately, this 490nm 700nm Fully waterproof insertion section
‘rheostat’ type control increases the ‘yellowing’ of the resultant illumination. Photo and video documentation
.2
For this reason, all Olympus light sources use a mechanical shutter to
control light output, as the full colour temperature of the lamp is preserved.
480nm
.1
POWER
470nm
∞
200000K
100000K
65000K
4800 K
36000K
28540K
23600K
19000K
15000K
10000K
.0 450nm
0
Y
metal-halide or UHP lamp will produce a higher illumination level (in X .0 .1 .2 .3 .4 .5 .6 .7 .8
output per unit area) than a 500W tungsten-halogen lamp.
16 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 09
Industrial Videoscopes Light Sources
SERIES 5
6 VIDEOSCOPES CONTROL UNIT FOR SERIES 6 & SERIES 5 VIDEOSCOPES TUNGSTEN HALOGEN LIGHT SOURCES LIGHT SOURCE
INDUSTRIAL VIDEOSCOPE
INDUSTRIAL VIDEOSCOPE CONTROL UNIT ILK-7/ILK-7A/ILK-7B KLS-131
IV6C5-110/160 IV-6A The ILK-7 range of light sources incorporates a 150W tungsten-halogen The KLS-131 light source can be used as a stand alone system or as
Loaded with every imaginable leading edge RVI function, the IV-6A is designed to lamp offering features necessary to meet most industrial needs. part of the modular borescope system. It is available with either XLR
The IV6C5 Series offers working lengths of up to 16 metres. make your inspections as efficient and effective as possible. SPECIFICATIONS connector or crocodile clips for car battery use.
● Remote control operation using the Series 6 scope’s “Five Button” control pad. Lamp: 150W tungsten-halogen SPECIFICATIONS
RADIATION RESISTANT VIDEOSCOPES ● Extended exposure time for darker areas. Weight: 2.3kg Lamp: 50W tungsten-halogen
● Automatic brightness adjustment.
IV6C5X1-75/110 ● Zooming and virtual scrolling (panning) with moving images.
Dimensions: 178 x 230 x 76mm Weight: 0.6kg
Power Supply: ILK-7 – 100-120V 50-60Hz, 115V 400Hz Dimensions: 137 x 53mm
The IV6C5X1 Series scopes are radiation-resistant up to ● Built-in image enhancement function.
● Compatible with Series 5 scopes when MAJ-565 adaptor is used. ILK-7A – 100-240V 50-60Hz, 115V 400Hz 12VDC Power Supply 12VDC
50Gy (5000 Rad).
● Compatible with fiberscopes and borescopes when OTC-6 C-Mount CCD ILK-7B – 100-240V 50-60Hz, 115V 400Hz Power Consumption: 80W
Camera is used (see below). Power Consumption: 190W max
SPECIFICATIONS
Voltage: 12V DC
Power Consumption:
24W maximum
Dimensions:
174(W) x 259(H) x 2241(D) mm
Weight: 1.5Kg
IV5C6X1-15
IV6C6-13
IV6C6-20
IV6C6-35
IV6C6-50
IV6C6-75
IV8C6-20
IV8C6-35
IV8C6-50
IV8C6-75
Distal end Diameter ø5.1mm ø6.0mm ø8.4mm
D40N (NTSC)/D40P (PAL) Bending Angualtion 150º up/down MAJ-456 Rigid Sleeve
INFRA-RED TELESCOPIC CAMERA SYSTEM section
Flexibility
range direction
150º in up/down and right/left directions
1,340mm
2,040mm
3,540mm
5,030mm
7,530mm
2,010mm
3,510mm
5,000mm
7,500mm
Illumination system White LED illumination
Camera optical
Automatic adjustment by means of AGC and electric
mounted on a telescopic arm, together with a compact monitor and Working length 1,500mm
system Brightness adjustment system
shutter battery module. The complete system is supplied in a single rugged
Distal end: ø18mm
Outer diameter
Flexible portion (camera cable): ø9.0mm carrying case.
Insertion tube ■ IV5C6 Optical Adaptor Specifications The IV5C6 has short rigid section at the distal end,
Working length 40m ● Up to 12 metres viewing distance in darkness. for PT-6 inspection
Minimum bending radius R120mm Optical system Distal end
● Up to 2 hours battery life in continuous use.
Frame 480(W) x 480 (H) x 350(D) mm Field of Direction of Depth of field F No Outer Rigid distal
● High resolution monochrome monitor. view view diameter end length
m
Video signal NTSC, PAL 2 lines (RCA, BNC)
.9m
Cable drum
● Robust carrying case. Forward
26
Power supply 12V DC (operating voltage range:10.8~13.2V DC) AT120D-IV5C6X1 120º 14~100mm 5.2 17.5mm
2.7
.5m
(integrated with 5.1mm
R1
.7
17
Maximum power consumption Approx 6W (camera & LED) AT90S-IV5C6X1 90º Slide 12~100mm 5.2 22.8mm
R6
control unit)
Output power supply 1 line 12V DC, 2A (max)
Weight 14.5Kg ■ IV6C6 Optical Adaptor Specifications
Rated input 100~240V AC (50/60Hz) IV5C6X1 IV6C6
AC adaptor Optical system Distal end
Rated output 12V DC, 2.5A
Field of Direction of Depth of field F No Outer Rigid distal
Other Provided accessories Accessory storage case, AC adaptor, view view diameter end length*1
Video cable RCA-RCA
AT40D-IV6C6 40º 330 ~∞mm 3.0 26.9mm
AT80D/NF-IV6C6 80º 10 ~∞mm 13.0 27.5mm
AT80D/NF-IV6C6 80º Forward 34 ~∞mm 4.5 27.4mm
■ IV7D6X1/IV7D6X2 Scope Specifications
■ Camera Head for PT400 Specifications Field of view 120º
AT120D/NF-IV6C6 120º 5 ~∞mm 12.5 27.0mm Optical
D23N (NTSC) D23P D40N (NTSC)
(PAL) D40P (PAL)
AT120D/FF-IV6C6 120º 20 ~∞mm 5.5 26.9mm system Direction of view Forward viewing
Field of view 80º 100º ø6.0mm
Optical system Direction of view Forward AT80S-IV6C6 80º 23~200mm 5.0 32.3mm Depth of field 9 to 80mm
Depth of field 20mm~∞mm (adjustable focus) AT120S/NF-IV6C6 120º Side 1~9mm 15.5 32.3mm Outer diameter ø7.3mm
Distal end
Distal end Outer diameter 23mm 40mm AT120S/FF-IV6C6 120º 7~90mm 8.0 32.3mm Rigid distal end length 19.8mm
AT60D/60D-IV6C6*2 60º/60º Direct/Direct 7~30mm 9.3 38mm Insertion Bending section Angulation range 130º in up/down and right/left directions
● Operating temperature: Insertion tube: In air: 0~40ºC tube
AT60S/60S-IV6C6*2 60º/60º Side/Side 6~30mm 9.3 44mm Flexible portion (tube) Flexibility Tapered Flex Tube
● Operating pressure: In air: 1013hPa
Outer diameter ø7.3mm
In water: 1013~1114hPa ■ IV8C6 Optical Adaptor Specifications Working length 2,610mm
● Waterproof properties: Watertight design, waterproof structure (3m depth of water)
Corrosion of heat exchanger end plate Optical system Distal end Channel Inner diameter ø1.7mm
Field of Direction of Depth of field F No Outer Rigid distal Universal cord length 2,000mm
view view diameter end length*1
150 x 46 x 28mm (compact version) including illuminator
Size AT40D-IV8C6 40º 200 ~∞mm 2.5 26.2mm
230 x 46 x 28mm (standard version) including illuminator
AT80D-IV8C6 80º 40 ~∞mm 5.5 29.4mm
Custom Packaging Viewing head
Camera
Sensitivity
Monochrome, 380 x 420 lines resolution
0.2 lux at fl.2
Infrared LED array - 850nm (compact version)
AT120D/NF-IV8C6
AT120D/FF-IV8C6
120º
120º
Forward
5 ~∞mm 14.0
45 ~∞mm 3.0
29.6mm
29.3mm
■ MAJ-456 Rigid Sleeve Specifications
Field of view 120º
Illumination ø8.4mm Optical system Direction of view Side view
- 950nm (standard convert version) AT80S-IV8C6 80º 22 ~∞mm 6.0 36.4mm
Side Depth of field 7~80mm
Power 12V DC, supplied by battery within chest pouch AT120S-IV8C6 120º 3 ~55mm 16.0 35.8mm
Packaging Type Lightweight, telescopic AT120D/120S-IV8C6 120º/120º Forward/Side 5~∞mm/3~∞mm 5/9 28.0mm Insertion tube
Outer diameter ø8mm
AT60D/60D-IV8C6*2 60º/60º Forward/Forward 5~50mm/5~50mm 11/11 24.0mm Working length 338mm
Packaging has always been a very important part of the Olympus Telescopic Pole Length 435 - 1530mm (extended)
Weight 0.5kg (including camera head/ illuminator) *1 When the Adaptor is attached to the scope. Total length 420mm
product range. We have therefore standardised our packaging to suit *2 For 3D measurement.
Type Monochrome - CRT
various customer needs including dedicated customised packaging for Monitor Size 120 x 230 x 60mm with 4" screen
system configurations. Resolution 420 lines Series 6 systems can be conveniently ■ Operating Environment for Series 6 Videoscopes
Olympus can offer a variety of hardcase and softbag solutions. Type 12V 2.5Ah Cyclon, sealed lead acid packaged (see page 18 for details). ● Operating temperature: Insertion tube: In air: -10~80ºC (14~176ºF)*
Minimum: 2 hours continuous use (compact version) All systems require a control unit and In water: 10~30ºC (50~86ºF)**
Battery Run Time
1 hours continuous use (standard version) All portions except insertion tube: In air: 0~40ºC (32~104ºF)
Charge Time 2 hours provides 95% capacity, full charge approx 8 hours
can be used with digital image storage ● Operating pressure: Insertion tube:
Type Constant voltage devices (see page 8). In air: 1013hPa (normal pressure) (IV6C6/8C6)
Battery Charger Input 198 - 264V AC, 50Hz or 100 - 110V AC, 60Hz In water: 1013 (normal pressure)~1360hPa (1~1.35atm) (IV6C6/8C6-13,20,35)
Output 14.4V DC max, 2.2A 1013 (normal pressure)~1773hPa (1~1.75atm) (IV6C6/8C6-50,75)
Chest Pouch Padded nylon with sun shield. Neck and waist straps with quick release buckles All portions except insertion tube: In air: 1013hPa (1atm normal pressure)
Double skinned, toughtened ABS. Waterproof, with O ring seal and pressure ● Liquid resistance: Insertion tube: Withstands machine oil, light oil and 5% salt water
Carrying Case (10~30ºC or 50~86ºF) (normal temperature).
relief valve.
Telescopic pole with camera head/ illumination, control unit, 4" monochrome monitor, * At 50~80ºC atmosphere, use the instrument at a relative humidity of 40% or below. Using the instrument at a higher
Standard Set
1 x battery pack, battery charger, chest pouch, carrying case and instructions. humidity may cause equipment damage.
** Insertion tube of IV7D6 and IV5C6X1 scopes is splashproof, except for the channel of IV7D6, which is not fluid-proof.
Accessories Protective cover for camera head. Wrist strap.
18 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 07
Industrial Videoscopes Accessories
IPLEX SX SERIES
INDUSTRIAL VIDEOSCOPE SYSTEM
IPLEX SX 6.2mm (with channel) 35mm SLR CAMERA
IPLEX SX 4.4mm SC35 (Type 15)
Purpose-built to meet the specific requirements of gas turbine By using an optional OM Adaptor, images observed by an Olympus
inspection, the new IPLEX SX provides improved access to intricate Industrial fiberscope or borescope can be easily photographed with
engine interiors, enhanced hooking and retrieval operation for automatic exposure.
exceptional ease of use, together with all high-quality capabilities Note: Ordinary photography is not possible with this camera.
synonymous with Olympus, such as advanced observation performance
and proven stereo measurement.
● All features of the IPLEX SA unit including stereo measurement plus
working channel in 6.2mm model.
● Control unit can be removed from case for enhanced portability.
■ IPLEX SX Optical Adaptor Specifications camera alone, and the internal view can be documented when the IF3 Series SM-2S 1 1.0 1.0
Optimized for jet engine inspection Optical System Distal End camera is connected to the endoscope. IF7D3X3-26, 32
IF13D3-60, IF8D3X2-23
Scope Optical Adapter
Field Direction Depth F Outer Rigid distal Image Carriers SM-3S 2 1.375 0.529
Olympus’s innovative Tapered Flex
of view of view of field No. diameter end length*
technology is well known for its unequaled AT120D/NF-IV76X1 120º 4~190mm 9.2 20.6mm IF4D4/4S4, IF5D4X1 AI-3M 3 1.0 1.0
insertion capability. The IPLEX SX’s Forward IF6D4, IF8D4, IF11D4
AT120D/FF-IV76X1 120º 25~∞mm 3.3 20.5mm
IV7635X1 ø6.2mm IF4D5/4S5, IF6C5, IF6C5X1
Steel Mesh Resin Braided “Tough Tapered Flex” tube has been AT80S-IV76X1 80º
Side
18~∞mm 4.0 24.6mm IF8C5, IF11C5 AI-4M 4 1.319 0.575
coil interior tube exterior designed to provide optimum flexibility in AT120S-IV76X1 120º 5~∞mm 5.9 24.6mm
AT40D-IV74 40º 200~∞mm 2.4 19.7mm IF6PD4, IF2D4, IF2D5 SM-R 5 1.0 1.0
aircraft engine inspection and excellent Rigid Borescopes
AT80D/NF-IV74 80º 8~∞mm 9.5 20.2mm
resistance to crushing. AT80D/FF-IV74 80º Forward 35~∞mm 3.1 20.1mm
Small Diameter Borescopes
AK-1M 6 1.8 0.31
Modelscope
AT120D/NF-IV74 120º 4~190mm 9.2 20.2mm CAMEDIA digital camera connected to
IV7440X1 ø4.4mm
AT120D/FF-IV74 120º 25~∞mm 3.3 20.1mm Olympus Industrial fiberscope via AI-DC3
Various working tools available AT80S-IV74 80º 25~∞mm 3.7 23.1mm
Versatile tools are available to meet a wide AT120S/NF-IV74 120º Side 1~20mm 9.6 23.1mm C-MOUNT ADAPTORS
range of inspection requirements such as AT120S/FF-IV74 120º 6~∞mm 6.0 23.1mm For connection of TV cameras to Fiberscopes and Rigid Borescopes.
*The rigid portion at the scope’s distal end when the adapter is mounted
retrieval of foreign objects and dropped
objects. Snare basket, 3-prong grasper,
1 2 3 4 5 6 7 8 9 10 11 12
magnet and alligator forceps are available. ■ Stereo Measurement Optical Adaptor Set Specifications
Optical System Distal End
Scope Set Name Optical Adapter Field Direction Depth F Outer Rigid distal
of view of view of field No. diameter end length*
Belt holder for hands-free operation CAMEDIA digital camera connected to
MAJ~1241D AT60D/60D-IV76X1 60º Forward 5~∞mm 26.7mm
IV7635X1 7.5 ø6.2mm Olympus Industrial borescope via AK-DC3
The remote control with channel port MAJ~1241S AT60S/60S-IV76X1 60º Side 4~∞mm 32.4mm
mounted can be attached to a belt around MAJ~1244D AT60D/60D-IV74 60º Forward 5~∞mm 26.3mm
IV7440X1 7.5 ø4.4mm ■ Specifications
MAJ~1244S AT50S/50S-IV74 50º Side 4~∞mm 30.7mm
your waist. This allows you to operate the AI-DC3 AK-DC3 Scope C-Mount adaptor Magnification ratio Brightness ratio
scope without having to hold the remote IF4D5/4S5 Series 5 industrial rigid borescopes
IF3 Series MC-04 0.8 1.6
control, and leaves your hands totally free K12/17/27 (mini borescopes)
■ IPLEX SX Operating Environment IF5D4X1 IF7D3X3-26, 32 MC-05 1 1.0 1.0
X009/X012/X017/X025 (small diameter borescopes) IF13D3-60, IF8D3X2-23 MC-08 1.6 0.39
for other tasks when you’re not operating ● Operating temperature: Insertion tube: In air: -25~80ºC* Compatible scope
IF6C5X1 IF6PD4
2
Image Carriers MC-10 3 2.0 0.25
the remote control. Under water: 10~30ºC (IV7440X1 only)
IF8C5 IF2D5 AI-10C 0.8 1.56
Other parts than above: In air: 0~40ºC IF4D4/4S4, IF5D4X1 4
IF11C5 IF8D4X2/X3
● Operating atmospheric pressure: Insertion tube: In air: 1013hPa (1atm) IF6D4, IF8D4, IF11D4 AI-11C 5 1.0 1.0
In water: 1013~1418hPa (1~1.96atm) (IV7440X1 only) Connection with camera Screwed into tripod socket of camera*
Portable package design Other parts than above: In air:1013hPa (1atm) C-2000ZOOM/C-2020ZOOM/C-3030ZOOM/C-3100ZOOM/
IF4D5/4S5, IF6C5, IF6C5X1
IF8C5, IF11C5
AI-12C 6 1.51 0.44
Compatible camera AI-3C 7 2.0 0.25
● Liquid resistance: Insertion tube, channel port, remote control: C-4040ZOOM/C-4100ZOOM/C-3020ZOOM/C-4000ZOOM/C-5050ZOOM
An integrated all-in-one design offers Two components: stay-provided mount for scope eyepiece and AK2-3C 0.45 –
Machine oil, light oil and 5% saline is attached. Construction
superior portability and faster, more ● Other parts than above: The SX case outer finish is resistant to machine oil, light oil and 5% intermediate ring for camera filter thread. AK2-4C 0.6 –
IF6PD4, IF2D4, IF2D5 AK2-5C 0.75 1.8
efficient set-up and takedown. Removing saline is attached. Note: When the adaptor is connected to the fiberscope, interference between the fiberoptic matrix and Rigid Borescopes
8
● the LCD pixels may cause striped patterns (moiré). AK2-10C 9 1.0 1.0
the control unit from the case allows you to Waterproof: Insertion tube: Can be used under water (IV7440X1 only). Small Diameter Borescopes
Drip-proof: Remote control, LCD monitor, channel port: To prevent moiré, set the camera’s focus to manual mode. AK2-20C 10 1.35 0.55
carry the IPLEX SX on your shoulder, Modelscope
Can be used in rain but cannot be used under water. * When the adaptor is connected to the camera, the camera’s tripod socket cannot be used. MC-R44 11 1.85 0.3
enhancing mobility in confined spaces and Other parts than above: Neither waterproof nor drip-proof.
To secure the camera on a tripod, use the optional fiberscope holder (MB-936/MB-937) or borescope
MC-R58 12 2.4 0.17
tripod mount (KN-29).
elevated locations. * Angulation may be affected by extreme temperatures.
06 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 19
Accessories Industrial Videoscopes
Viewing Adaptors Engine Turning Tools 3D EYE-TREK STEREO MEASUREMENT (IPLEX SA STEREO MEASUREMENT)
These adaptors allow the eyepiece of a rigid borescope or flexible The Olympus Electronic Engine Turning Tool (OTT) can offer increased Olympus’s stereo measurement technology uses triangulation to
When the 3D Eye-Trek face-
fiberscope to be extended or angled for a more comfortable viewing speed and efficiency for all internal turbine inspections. Using a simple measure image information captured by two parallax lenses. With six
mounted display is connected to
position. hand held controller each blade can be precisely positioned for an different measurement modes available, high-precision measurement
the remote control, surface
optimal view, allowing single operator inspections. The Engine Turning capabilities are available from any angle.
contours that would normally be
Tool is designed to be attached to engines quickly and easily - the Distance:
difficult to detect can be observed Measures the total length of a defect or
engine-specific adaptor connect the drive motor directly to the engines’
in three dimensions where they zone of damage.
gearbox turning point or air starter position. Once connected the
can easily be interpreted. Point-to-Line:
operator can select rotation speed and direction (forward or reverse). Measure the distance between a
The Olympus Turning Tool is suitable for use on most turbine engines for hypothetical line between two designated
aerospace and power generation applications. positions and the required point.
Depth:
The Olympus Turning Tool uses an electric stepper motor rather than Measures the depth/height of corrosion,
compressed air, making its operation precise, quiet and efficient. The protrusion and indentation from a
range consists of four different models, depending on the specific engine hypothetical plane to the required point.
Lines:
requirements. Features include blade identification on an easy to read
Total length of a crack with complicated
LED, convenient foot switch, offering hands-free operation and many Left Right
contours can be measured by plotting
other specific features, outlined below. multiple positions.
3D Image Area:
● OTT-1 Calculates the area of a burn or zone of damage
■ IPLEX Equipment Components and Functions surrounded by multiple designated positions.
This turning tool package is a high specification unit. A complete kit
Profile:
includes a Central Processing Unit, Hand Controller, Foot Pedal, IPLEX SA IPLEX SA IPLEX IPLEX SX
■ Viewing Adaptors Specifications STEREO MEASUREMENT Hard-to-see irregularities are simulated with
Software Module, Engine Adaptor and all required cables. Features of Scope Variation computer graphics for easier analysis.
Adaptor Name Angle Arm Length / Magnification
this turning tool include video overlay, variable torque settings, Outer diameter Insertion tube length Product code
AK2-18-90 90° angle 18cm arm interchangeable engine adaptor, backlash compensation, blade counting ø4.4mm
3.5m IV7435A IV7435A IV7435 –
PC SOLUTION (IPLEX SA and SX PC COMPATIBILITY)
4.0m – – – IV7440X1
AK2-9-60 60° angle 9cm arm and tagging, auto indexing and adjustable rotation speed, direction and All aspects of inspection operation can be controlled with a PC
3.5m IV7635A IV7635A IV7635 IV7635X1
AK2-8-90 90° angle 8cm arm
dwell time. 5.0m IV7650A IV7650A IV7650 – connected to IPLEX via a USB cable. Stored image data can also be
ø6.0mm
20 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 05
Industrial Videoscopes Accessories
3D EYE-TREK (for IPLEX) CCTV EQUIPMENT
FMD-3DN (NTSC) Various CCD cameras, CRT and LCD monitors and video recording
equipment products are available for TV observation.
FMD-3DP (PAL) For details of the latest models, contact your local Olympus sales
Allows you to confirm the conditions of an inspection site with super- representative.
real three-dimensional images. 3D Eye-Trek makes it easier to get an
accurate sense of distance, also facilitating insertion of the scope and
IPLEX SERIES access to the site.
04 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 21
System Charts Industrial Videoscopes
Flexible portion
VCR Light guide fiber Light source
Depth of field Bending section Electronic control unit
Objective lens
and optical tip adaptor
Remote control
USB or
Recording Card
Ultra-compact CCD for image transmission.
PC 4 way Tip Angulation Optical Tip Adaptors
High-resolution images are displayed on a TV monitor.
The videoscope captures light reflected from a subject through an
objective lens and directs it to the surface on the CCD. The CCD then
IPLEX SX converts the light into electrical signals and transfers this data to the
3D Eye-Trek
videoscope control unit. The unit then sends a video output to the monitor.
MAIN APPLICATIONS
Optical Adaptors Remote Control Ideal when higher resolution, longer insertion and
Extension Cable brighter images than those obtainable with fiberscopes Forward/Side-Viewing Adaptor Ultra-Wide-Angle Adaptor
22 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 03
System Charts
Olympus Industrial Endoscopes
meet needs across a wide range of areas, FIBERSCOPES AND RIGID BORESCOPES
from maintenance to R & D
Eyeball Observation System Digital Photography System
Olympus technology has made it possible to obtain views from internal or difficult to reach areas, easily and quickly,
Olympus
without teardown or disassembly, and without destroying exterior features. Digital Camera Adaptor CAMEDIA
AI-DC3/AK-DC3
Olympus has a comprehensive range of industrial endoscopes, such as videoscopes, fiberscopes and borescopes, with a Digital Camera
range of ancillary equipment to match your specific requirements. These scopes, all designed and made by Olympus, offer Industrial Fiberscope Optical
Adaptor
superior imaging and performance achieved through combining Olympus expertise in optics, electronics and precision
mechanics gained through years of experience. With the ease of use and durability of Olympus products, it is clear that Video System
Olympus Industrial endoscopes can make a large contribution to productivity, safety and reliability in your industry. LCD Monitor
Light Source
Rigid Borescope
C-Mount
Adaptor Video Monitor
SOME APPLICATION EXAMPLES Light Guide Cable
TV Camera VCR
Aerospace Industries Small Diameter Borescope
For examination of Airframe and Gas turbines in research,
production and maintenance for military and civil aircraft. Also Video Printer
rockets and rocket engines.
OM Adaptor
Security
For detection of Narcotics and other contraband items, for bomb
Image Recorder PCMCIA PC
and weapons searches, and for locating those trapped following IW-R1 Memory Card
disasters.
Power Generation
For maintenance of heat exchange pipes, condensers, piping and Film Photography Digital Storage and
Measurement System
Floppy Disk
Flash Path PC
turbines at nuclear, fossil fuel and hydroelectric power generation System DSM-2
facilities.
Industrial Machinery
For quality control and maintenance of motors, boilers, heat
exchangers and machine tools.
Refineries/Chemical Plants
For routine and urgent inspection of process piping, pressurised
storage reservoirs, heat exchangers, boilers etc.
Automotive
For quality control examinations of engines, hydraulic components
and injection nozzles, as well as detection of leaks, squeaks and
rattles in assembled vehicles.
Electrical Equipment/Electronics Industries
For monitoring operation of equipment and factory automation
through automatic inspection and positioning, as well as a wealth
of R & D applications.
Gas Pumping & Delivery Systems
For monitoring corrosion inside and outside gas pipes, the
presence of water infiltration and flaws in outlets, and for
maintenance of gas turbines used for pumping.
Steel Industries
For equipment maintenance as well as quality control of pipes and
tubes.
Architecture/Construction
For examination of walls, ducts, structured joints, as well as for
viewing inside architectural models.
Education/Research
For monitoring animals and insects, root systems of plants etc.
Also for historical and archaeological applications such as internal
inspection of statues and tombs.
Railroad/Shipping
For routine inspection of motors, turbines, diesel engines, piping etc.
Water Supply/Drainage
For locating rust and blockages inside pipe systems.
Useful for documentation before and after lining is coated.
02 OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE OLYMPUS INDUSTRIAL ENDOSCOPY SYSTEM GUIDE 23