P N M T: PNMT (Java Version) Operation Manual
P N M T: PNMT (Java Version) Operation Manual
P ASOLINK
N ETWORK
PNMT (Java version)
Operation Manual
M ANAGEMENT (for PASOLINK+ STM-1)
T ERMINAL
NEC Corporation
Copyright © 2006
Submission Prohibited ROI-S05593
NEC Internal Use Only
Table of Contents
DOCUMENT WARRANTY ......................................................................................................... 1
i
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.16.7 IF Loopback (STM-1 near-end loopback)...............................................................40
2.16.8 ALS Restart ............................................................................................................40
2.16.9 Selecting TX Mute status .......................................................................................41
2.16.10 TX Frequency ......................................................................................................41
2.16.11 RX Frequency ......................................................................................................41
2.16.12 Selecting Carrier Wave status............................................................................41
2.16.13 ATPC Manual......................................................................................................42
2.16.14 XPIC Forced Reset (for XPIC systems only) ......................................................42
2.16.15 Linearizer Control (for Linearizer-systems only) ..............................................42
2.16.16 LAN Device Reset................................................................................................43
2.17 EQUIPMENT SETUP ......................................................................................................44
2.17.1 Equipment Configuration Monitor and Setup ......................................................44
2.17.2 Setup .......................................................................................................................47
2.17.3 Editing the NE Name .............................................................................................49
2.17.4 Editing the Note for NE .........................................................................................49
2.18 PROVISIONING .............................................................................................................50
2.18.1 Provisioning window...............................................................................................50
2.18.2 MAIN INTFC ..........................................................................................................51
2.18.3 Overhead (OH) Assignment ...................................................................................53
2.18.4 Manual Transmit Power Control (MTPC) Status .................................................54
2.18.5 Automatic Transmit Power Control (ATPC) Status .............................................55
2.18.6 SW Priority .............................................................................................................57
2.18.7 Sub INTFC..............................................................................................................58
2.18.8 Access Code .............................................................................................................59
2.18.9 BER Threshold........................................................................................................60
2.18.10 MS-AIS Generation.............................................................................................62
2.19 LINK PERFORMANCE MONITOR ...................................................................................63
2.19.1 Viewing Summary Link Performance Monitor .....................................................63
2.19.2 Threshold Setting ...................................................................................................64
2.19.3 Link Performance Monitor (Daily Data) window..................................................65
2.19.4 Link Performance Monitor (15-min Data) window ...............................................66
2.20 NE STORED LOG..........................................................................................................67
2.20.1 NE Stored Log monitor...........................................................................................67
2.21 VERSION TAB ...............................................................................................................68
2.21.1 Version Monitor ......................................................................................................68
2.22 LICENSE IMPORT .........................................................................................................69
2.22.1 License import ........................................................................................................69
3 APPENDIX A: RESTRICTION ........................................................................................... 73
ii
Submission Prohibited ROI-S05593
NEC Internal Use Only
Document Warranty
1. The information contained in this document is subject to change without prior notice.
2. The PNMS/PNMT screenshots in this manual are only examples. Screens will vary according
to equipment configurations, equipment operation modes, setting parameters, PNMS/PNMT
application program version, etc. Screens contained in this manual are current at the time of
publication; however, and may differ slightly from the actual screens displayed on your
PNMS/PNMT.
3. To use this manual you need a sound understanding of the restrictions, limitations and
precautions involved in operating the equipment properly. Refer to the equipment manual to
ensure proper operation of the equipment.
1
Submission Prohibited ROI-S05593
NEC Internal Use Only
1 Getting Started
1.1 Introduction
The PASOLINK Network Management Terminal (PNMT) was developed by NEC to manage of
its PASOLINK fixed point-to-point wireless access system networks. The PNMT is a scaled
down version of the PASOLINK Network Management System (PNMS) that is designed as a
maintenance tool for field engineers to locally and remotely monitor alarms, control points,
generate reports, and archive data, all within a familiar graphical user interface, and all in real time.
The PNMT is a mobile laptop computer fitted with the NEC PNMT software package that
interfaces and controls NEC’s PASOLINK short haul wireless communications equipment.
This software package remotely monitors and controls the status and configuration of an entire
PASOLINK network with associated equipment including the performance of the actual
microwave links.
2
Submission Prohibited ROI-S05593
NEC Internal Use Only
1.3 PNMT Communication Interfaces
1.3.1 Communications
Communications between the PNMT and the wireless communications network equipment can be:
ODU
PNMT port
PASOLINK+ IDU
PNMT Cable
PNMT
Figure 1 Connecting the PNMT to PASOLINK+ IDU
The PNMT port consists of an RJ-45 connector and connects to a Control (CTRL) Module
installed in the IDU via a serial cable, which is connected to the relevant communications port of
the PNMT Computer. The PNMT Port has the following properties:
Parity: None
3
Submission Prohibited ROI-S05593
NEC Internal Use Only
The following table is the pin assignment for the connection between the IDU PNMT port and the
PNMT PC.
PC (PNMT) PASOLINK+
PNMT port
RS-232C RS-232C
1 DCD 1 1 1 CD
2 RXD 2 2 2 TXD
3 TXD 3 3 3 RXD
4 DTR 4 4 4 DSR
5 GND 5 5 5 GND
6 DSR 6 6 6 DTR
7 RTS 7 7 7 CTS
8 CTS 8 8 8 RTS
9 RI 9
4
Submission Prohibited ROI-S05593
NEC Internal Use Only
2 System Operation & Maintenance
This chapter explains the menu structure and procedures for operation of the PNMT. The
explanation uses typical PNMT screenshots to illustrate the menu hierarchy.
5
Submission Prohibited ROI-S05593
NEC Internal Use Only
NE-Specific Menu Bar One Touch
Expandable
Title Bar
Button Block Diagram
Common
Menu Bar
Common
Tool Bar
Data
Window
6
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.2 Launching the PNMT Application
To start PNMT:
1. Turn system power ON.
NOTE
Connect the PNMT cable 30 seconds after IDU power has
been turned ON and make sure that the PNMT cable is
connected between Com 1 port of the PNMT PC and the
PNMT port of the IDU.
2. Login to Windows.
3. Click Start Æ Programs Æ PNMTj Æ Pnmt, then continue to the login window.
NOTE
Please do not change the clock settings of your computer
once PNMT has started
7
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.3 Login
Users are registered by means of login name and password.
To protect the network and network management system from unauthorized access or unauthorized
modifications, five levels of users with different access privileges are defined (refer to the table
shown in section 2.3.1 User Access Privilege Levels). The functions that are available depend on
the individual user’s access level.
The highest level or administrator level has full access to the network and network management
system.
To login:
1. Start PNMT, and the Login window appears.
Login window
2. Enter the <User name>.
3. Enter the valid <Password> for the specific user.
4. Click [Login].
If you want to exit the program, click [Exit].
8
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.3.1 User Access Privilege Levels
User Access Privileges for STM-1
9
Submission Prohibited ROI-S05593
NEC Internal Use Only
9: Available, –: Not Available
Function User Name and Accessible Functions
Category Item Monitor User Local Remote Admin
RX SW Priority – – 9 9 9
ACCESS CODE ACCESS CODE SETTING – – 9 9 9
ACCESS CODE – – 9 9 9
MAINT MAINT – 9 9 9 9
TX Frequency – – 9 9 9
TX Switch – – 9 9 9
RX Switch – – 9 9 9
Main Signal Loopback-1 – – 9 9 9
Main Signal Loopback-2 – – 9 9 9
ALS Restart – – 9 9 9
IF Loopback – – 9 9 9
CW (Mod Carrier) – – 9 9 9
TX Mute – – 9 9 9
ATPC Manual – – 9 9 9
XPIC Forced Reset – – 9 9 9
LINEARIZER CONTROL – – 9 9 9
LAN DEVICE RESET – – 9 9 9
Equipment Equipment Setup – – 9 9 9
Setup NE Name – – 9 9 9
Note – 9 9 9 9
Aux I/O Input Name – 9 9 9 9
Input Condition – 9 9 9 9
Input Status Strings – 9 9 9 9
Input X.733 – 9 9 9 9
Output Name – 9 9 9 9
Output Control – 9 9 9 9
Relay Configuration – 9 9 9 9
PMON PMON Threshold – 9 9 9 9
Save to disk – 9 9 9 9
Logging Save to disk – 9 9 9 9
CTRL
(MODEM, Reset – – 9 9 9
ODU)
*
Admin: Enabled to access all Network Elements.
*
Remote: Enabled to access all Network Elements.
(Disabled from changing network configuration and changing/downloading programs)
*
Local: Enabled to access Local NE and Opposite NE.
(Disabled from changing network configuration and changing/downloading programs)
*
User: Enabled to access items which do not affect to the equipment.
*
Monitor: Enabled only to monitor(disabled from control).
10
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.4 Shutting Down PNMT
To exit the PNMT application:
1. Click System -> Exit on the menu bar of the main window
11
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.5 Searching for and Connecting to Selected Network Elements
The summary description of the current Network Element (Network Element Name, Equipment
Type, Opposite Network Element, etc.) where PNMT is connected is displayed using this function.
Summary description of the opposite Network Element belonging to that link is also displayed.
To search for or connect to a Network Element in the network:
1. Click System Æ Connect… in menu bar of PNMT main window.
NOTE
Initially only the current NE physically connected to the
PNMT and its opposite NE will be shown on the Network
Element List.
2. Click the Search for Element icon ( ) in the tool bar or List Æ Search for Network
Element in the menu bar of the Network Element List window to display all connectable
Network Elements in the network.
3. Select and highlight the Network Element to be viewed.
4. Click the Connect to Network Element icon ( ) in the tool bar or List Æ Connect to
Network Element in the menu bar of the Network Element List window. The PNMT main
window of the selected Network Element and its opposite Network Element will be
displayed.
12
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.6 Change Password
To change the password:
1. Click System Æ Change Password on the menu bar on main window.
NOTE
For details on initial user name and password, please refer
to PNMT Installation manual.
13
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.7 Alarm Buzzer Setting
This function is used to activate and set the Alarm Buzzer. The desired sound scheme can also be
set using this function.
To set the Alarm Buzzer:
1. Click System Æ Alarm Buzzer in the main window.
2. Select the Wave file box to activate the buzzer. No sound is the factory setting of the
PNMT.
3. Enter the location of the sound file (*.wav) Otherwise; click […] to locate the desired file.
You can also preview the *.wav file by clicking on the arrow next to the browse button.
4. Click [OK] to activate the new setting.
NOTE
When the text column is a blank, it is possible to set it. In
this case, the buzzer sound does not ring even though the
buzzer stop function is enabled.
14
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.8 Refresh
This function is supported only by PNMT. This function enables PNMT to acquire all status
manually and to update equipment information
To Refresh:
1. Click Refresh Æ Refresh in the main window or click on the refresh icon in the tool bar.
NOTE
Metered items such as TX power, RX level, power supply
and BER are automatically refreshed every 15 seconds.
This function is used when the immediate refresh of these
metered items is necessary or when confirmation of all
current status information is immediately required.
15
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.9 Remote Viewing PNMT main window
You can view a target link within one Root-NE cluster of the Pasolink+ network by searching
through the connected NEs and then connecting to a target NE. Please refer to Section 2.5
Searching for and Connecting to Selected Network Elements. This function allows remote
connection to any NE in the network.
NOTE: For multi-Root-NE network, you can only connect to NEs that belong to the same network as
the Root-NE for the local NE to which you are directly connected via the PNMT cable.
16
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.10 License
To protect PNMT functions, the PNMT application includes license files.
To display the current license status,
1. Click Help Æ License… in the main window.
17
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.11 Overall Tab
This tab is displayed on startup. The Overall tab provides an overall snapshot of the most
significant monitored items in the NE.
The Overall tab gives a snapshot of the important settings of the NE. This window only displays
current settings and there is no control function associated with this window.
Overall Tab
1+0 Configuration
Overall Tab
1+1 Twinpath Configuration
Overall Tab
1+1 Standby Configuration
Overall Tab
1+1 Hot Standby Configuration
(for XPIC system)
18
Submission Prohibited ROI-S05593
NEC Internal Use Only
The following items are displayed in this tab:
o MTPC TX Power – the current value (in dB) of the Manual Transmitter Power Control
attenuation set in the ODU. The MTPC Attenuation will only have a valid data if the
MTPC is enabled.
o TX Frequency – the current transmit frequency used.
o RX Frequency – the current receive frequency used.
o Frame ID – the set frame ID of the NE.
o TX Power Control – shows the current power control mode used by the ODU. The TX
Power Control is either Automatic Transmitter Power Control (ATPC) or Manual
Transmitter Power Control (MTPC).
o MAIN INTFC – shows the current main interface used by the IDU. The available
interfaces for the STM-1 signal are: Electrical, Optical and Optical Single Fiber (SF) and
10/100BASE-T.
o ALS – shows the current setting of the Automatic Laser Shutdown (ALS). It can either be
set to Enable or Disable. The ALS is an IDU function that intermittently turns on/off the
laser output when a certain period elapses after STM-1 LOS mode starts.
o MAINT – shows the current state of the Maintenance status.
o Selected TX (for Hot-standby configuration only) – shows the current system used for
signal transmission.
o Selected RX (for 1+1 system only) – shows the current system used for signal reception.
o XPIC (for XPIC system only) - shows the current setting of XPIC function.
The XPIC can be set to Master, Slave, or Not Used (disabled).
19
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.12 ODU Tab
This function is used to display the values and status of the monitored items of the ODU. This
window only displays current settings and there is no control function associated with this window.
To set the ODU parameters, see the chapters on Equipment Setup and Provisioning.
NOTE
Please refer to APPENDIX A RESTRICTION regarding ODU combinations.
20
Submission Prohibited ROI-S05593
NEC Internal Use Only
Monitored Items in the ODU
TX PORTION
Alarm ATPC Status (This portion of screen is
only active if ATPC is used.)
o TX INPUT: alarm occurs when the TX IF
input signal from the IDU is lost. Item/Status o Control Range*: Item and status area
area is shown with transparent letters and are shown and item area uses black
gray background in case of PS Alarm or font and status has no information in
CABLE Alarm. case of PS Alarm or CABLE Alarm.
o TX POWER: TX RF Power decreases 3 to 6 o RX Threshold Level*: Item and status
dB from nominal value. Item/Status area is area are shown and item area uses
shown with transparent letters and gray black font and status has no
background in case of PS Alarm or CABLE information in case of PS Alarm or
Alarm. CABLE Alarm.
Metering o Additional Attenuation*: Item and
status area are shown and item area
TX Power: The transmitted power of the ODU in
uses black font and status has no
dBm. Item and status area are shown and item
information in case of PS Alarm or
area uses black font and status has no information
CABLE Alarm.
in case of PS Alarm or CABLE Alarm.
o ODU ALM Mode *: Item and status
area are shown and item area uses
MTPC Status (This portion of screen is only
black font and status has no
active if MTPC is used.)
information in case of PS Alarm or
o MTPC TX Power *: Item and status area are CABLE Alarm.
shown and item area uses black font and
status has no information in case of PS
Alarm or CABLE Alarm.
o RX Threshold Level*: Item and status area
are shown and item area uses black font and
status has no information in case of PS
Alarm or CABLE Alarm.
o Additional Attenuation*: Item and status area
are shown and item area uses black font and
status has no information in case of PS
Alarm or CABLE Alarm.
RX PORTION
Alarm
RX LEVEL: Alarm occurs when the input level decreases by preset value from squelch level.
Item/Status area is shown with transparent letters and gray background in case of PS Alarm or
CABLE Alarm.
Metering
RX Level: The received level interpreted in dBm. Item and status area are shown and item area
uses black font and status has no information in case of PS Alarm or CABLE Alarm.
21
Submission Prohibited ROI-S05593
NEC Internal Use Only
COMMON PORTION
Alarm
o APC – alarm occurs when the Local Oscillator is locked out. Item/Status area is shown
with transparent letters and gray background in case of PS Alarm or CABLE Alarm.
o CABLE – alarm occurs when the communication between the ODU and the IDU is lost.
Item/Status area is shown with transparent letters and gray background in case of PS
Alarm.
Metering
Power Supply: Display PS value (V). Item/Status area is shown with transparent letters and
gray background in case of PS Alarm or CABLE Alarm.
* For the detailed description of these items, see 2.17 Equipment Setup and 2.18 Provisioning.
22
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.13 IDU Tab
This function is used to display the values and status of the monitored items of the IDU. This
window only displays current settings and no control functions are associated with this window.
To set the IDU parameters, see the chapters on Equipment Setup and Provisioning.
23
Submission Prohibited ROI-S05593
NEC Internal Use Only
Monitored Items in IDU tab
Following items are monitored:
MODULE COMMON PORTION
Alarm Alarm
MAIN INTFC – alarm occurs when the 150MB MAIN INTFC LOS – alarm occurs when the STM-1
INTFC/OPT INTFC module fails. signal in the MUX is lost. Item and status areas are
SUB INTFC – alarm occurs when the WS shown with transparent letters and gray background
INTFC/LAN CARD fails. in case Main INTFC is 10/100BASE-T.
MODEM – alarm occurs when there is a modem SUB INTFC LOS – alarm occurs when the WS
failure. Item/Status area is shown with transparent INFC/LAN CARD signal is lost.
letters and gray background in case of PS Alarm. MDCPU – alarm occurs when there is a failure in
the communication between modules. Item/Status
TX PORTION
area is shown with transparent letters and gray
Alarm background in case of PS Alarm.
LOF (MUX) – alarm occurs when loss of frame has
MOD - alarm occurs when the TX unit (modem)
occurred in the MUX. Item and status areas are
failed. Item/Status area is shown with transparent
shown with transparent letters and gray background
letters and gray background in case of PS Alarm.
in case Main INTFC is 10/100BASE-T.
Status LOF (DMR) – alarm occurs when loss of frame
Selected (for 1+1 Hot Standby systems only) occurred in the wireless portion.
E-BER (MUX) – alarm occurs when BER in the
Selected/Not Selected(This portion of screen is
MUX portion is worse than E-BER threshold. Item
only active if 1+1 system is used) and status areas are shown with transparent letters
This item shows if the System is selected or not and gray background in case Main INTFC is
selected. Item/Status area is shown with transparent 10/100BASE-T.
letters and gray background in case of PS Alarm or E-BER (DMR) – alarm occurs when BER in the
CABLE Alarm wireless portion is worse than threshold
RX PORTION Signal Degrade (MUX) – alarm occurs when BER
(in MUX) is worse than the Signal Degrade
Alarm threshold. Item and status areas are shown with
DEM – alarm occurs when the RX unit transparent letters and gray background in case
(demodulator) fails or the IF signal is lost. Main INTFC is 10/100BASE-T.
Item/Status area is shown with transparent letters Signal Degrade (DMR) – alarm occurs when BER
and gray background in case of PS Alarm. (in the radio portion) is worse than the threshold.
LOF – alarm occurs when loss of frame occurred. ATPC X CTRL – alarm occurs when triggered by
High BER – alarm occurs when the signal is loss of the cable connection between the master and
deteriorated below the threshold value. Item/Status slave IDU modules. (For XPIC systems only)
area is shown with transparent letters and gray Access Code – alarm occurs when the access code
background in case of PS Alarm. set up in the wireless communications equipment
Low BER – alarm occurs when the signal is does not match the opposite wireless
deteriorated below the threshold value. Item/Status communications unit. (Available on Linearizer-
area is shown with transparent letters and gray systems only)
background in case of PS Alarm. Main INTFC
Status ALS * Item and status areas are shown with
Selected (for 1+1 systems only) transparent letters and gray background in case
Selected/Not Selected(This portion of screen is Main INTFC is not Optical.
only active if 1+1 system is used) ALS Delay Time* Item and status areas are shown
This item shows if the System is selected or not with transparent letters and gray background in case
selected. Item/Status area is shown with transparent ALS is not available.
letters and gray background in case of PS Alarm or STM-1 Output Control - STM-1 output is shut off or
CABLE Alarm. not. Item and status areas are shown with
transparent letters and gray background in case MS-
AIS Generation is enabled.
Link – Link failure in Port1/Port2 on the LAN
24
Submission Prohibited ROI-S05593
NEC Internal Use Only
XPIC PORTION (for XPIC system only) occurs. ** Item and status areas are shown with
Alarm transparent letters and gray background in case
X IF LEVEL - alarm occurs when the IF signal Main INTFC is not 10/100BASE-T.
level of the cross polarization channel is lower than Collision - Collision condition in Port1/Port2 on the
required level. LAN occurs. **
Mode - LAN Speed **: Item and status areas are
Status shown with transparent letters and gray background
XPIC Reset – the status of XPIC function. in case Main INTFC is not 10/100BASE-T.
Duplex - Full or Half Duplex **: Item and status
Linearizer PORTION areas are shown with transparent letters and gray
Status background in case Main INTFC is not
Linearizer – the status of Linearizer function. 10/100BASE-T.
(Available on Linearizer-systems only) Link Down Control - 10/100BASE-T output is shut
off or not. ** Item and status areas are shown with
transparent letters and gray background in case
Main INTFC is not 10/100BASE-T.
SUB INTFC
SUB INTFC*
WS INTFC*
WS Line Length*
AIS Send
AIS RCVD
OH Assignment BER ALM Threshold (DMR)
Assignment* Signal Degrade - the current value of the signal
V11 –1/2* degrade threshold in the radio portion.
VF-1/2* E-BER – the current value of the E-BER threshold
10BASE-T*** in the DMR side.
* For the detailed description of this items see Equipment Setup and Provisioning
** For 10/100BASE-T Main INTFC only.
*** For 10BASE-T Sub INTFC and non Linearizer-systems only.
NOTE
Please refer to APPENDIX “RESTRICTION” about the IDU.
25
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.14 Auxiliary I/O Tab
4 relay outputs and 6 photocoupler inputs are provided in the IDU for external controls and alarms.
The setting for each relay output/photocoupler input is available by clicking on the selected device
in the Auxiliary I/O data window.
To monitor and set the Auxiliary I/O:
1. Select the Aux. I/O tab in the PNMT main window
26
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.14.1.1 Photocoupler Input Setting
To set the Photocoupler input:
1. Click on the selected [Input-n] in Aux. I/O tab.
2. The inputted properties will be displayed in the following window.
27
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.14.2 Relay Output Setting
28
Submission Prohibited ROI-S05593
NEC Internal Use Only
To set the relay configuration:
1. Click [Relay Configuration] in Aux. I/O window.
2. Select the HK-OUT used in the IDU. There are four (4) available HK-OUT’s in the
PASOLINK+ system. Selecting “1/2/3/4” button means all HK-OUT’s will be enabled;
“1/2/3” means only HK-OUT 1, 2 and 3 will be enabled; and so on. If the HK-OUT’s will not
be used, select “Disable” button.
3. Click on the button(s) that corresponds to the target alarm(s) and relay(s).
4. Click [Execute] to activate the new relay configuration.
5. Click [Close] when finished.
29
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.15 Control (CTRL) Tab
2.15.1 The Control Module
1. Select the CTRL tab in PNMT main window of the target NE.
The following items can be monitored and controlled in the CTRL
tab:
o Calendar Alarm:
o Date/Time
o CPU Reset
o Download - Configuration File
o Download - Program File
o Download - Equipment Config. File
o Upload - Configuration File
o Upload - Equipment Config. File
NOTE
To set the value of the Date and Time field to the
same value as that of the PNMT computer, check on
the Display PC Time box.
30
Submission Prohibited ROI-S05593
NEC Internal Use Only
a. To check the Date and Time on the Control module:
a-1. Select Get Date/Time in the Date/Time window.
a-2. Click [Execute].
a-3. The current date and time in the control will be displayed in the Date
and Time field.
b. To set the Date and Time on the Control module:
b-1. Select Set Date/Time in the Date/Time window.
b-2 Enter the date at Date field in the MM/dd/yyyy format, where MM is for month, dd is
for date and yyyy is for year.
b-3. Enter the time at the Time Field in the hh:mm format, where hh is for hour and mm is
for minutes.
b-4. Click [Execute].
b-5. Click [Close] when finished.
NOTE
Resetting the control module will not affect the traffic.
The connection to the selected NE will be disrupted a few
minutes, but it will be restored automatically.
NOTE
MAINT, TX Mute, CW, Loopback and ATPC Manual
will be cleared when the power is turned off and on, or the
RESET switch depressed.
NOTE
First, switch ON maintenance mode before executing
CPU Reset.
31
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.15.4 Downloading the Configuration Files to the Control Module
This function is used to download configuration files from the PNMT to the control module. The
configuration file pp_network.cfg contains the IP address of the NE as well as the IP address of
the opposite station and the information about the PASOLINK network where the NE is located.
The pp_mib.cfg file contains the information about the equipment (i.e. name, pm type, etc.) and
housekeeping (AUX I/O).
To download new configuration file to the NE:
1. Click [Configuration File] in the
CTRL tab’s Download
(PC>>CTRL) section.
2. Select the type of file to be
downloaded in the Type list.
3. Enter the location of the configuration
file in the File field, or click [Browse]
to locate the file on the local hard disk
or floppy diskette.
WARNING!!!
Make sure that the correct configuration file is
downloaded to the correct Control module. Incorrect
configuration files may lead to Control module or network
failure.
NOTE
First, switch ON maintenance mode before executing:
Download Configuration File.
5. A message window indicating the status of the operation will appear. It will close
automatically once the operation is finished.
WARNING:
Make sure that you have successfully downloaded the
configuration file before conducting an Update. Otherwise
the Control module will switch to an empty ROM that
may cause Control module failure.
32
Submission Prohibited ROI-S05593
NEC Internal Use Only
7. Select the appropriate box for the type of configuration file that will be updated. One or more
configuration files can be updated by checking the box opposite to the configuration file
name. Click [Execute] to start the operation. The "with ROM (CTRL Program) Switching"
box is for switching to the ROM with the new CTRL Program and has the same function that
was previously described in section 2.15.3 CPU Reset.
NOTE
When updating pp_network.cfg file, NE-to-NE
communication will be disrupted when the Control
module re-initialises to the new system configuration. This
WILL NOT affect the wireless link. During this time,
PNMT connection to the NE will be disrupted; but, it will
be restored automatically after the Control module resets.
NOTE
Updating the CTRL will not affect the traffic. The
connection to the selected Pasolink will be disrupted a few
minutes, but it will be restored automatically.
33
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.15.5 Downloading a new Program File to the Control Module
This function is used to update the application program via the Control module. This operation
affects only the NMS communication but not the wireless link, and will not disrupt
communications.
To download the program file to control module:
1. Click [Program File] in the CTRL tab’s Download
(PC>>CTRL) section.
2. Check the CTRL button. If you check the “with Self
Reset” box, the control module will be reset
automatically after program file download is
completed. In this case, you will not need to
complete steps 5 through 8.
3. Enter the appropriate location of the program file
(*.out) in the File field, or else click [Browse] to
locate the file.
WARNING!!!
Make sure that the correct program file is downloaded to
the Control module. Incorrect program files may lead to
equipment failure.
NOTE
Switch ON maintenance mode first before executing
Download Program File.
5. A message window will appear displaying the status of the operation. The message window
will close automatically once the download is completed.
NOTE
This operation may take several minutes depending on the
program file size.
34
Submission Prohibited ROI-S05593
NEC Internal Use Only
7. Check the with ROM (Program) Switching box.
8. Click [Execute] to complete the switch to the new program
file.
NOTE
The connection from PNMT to the selected Pasolink
equipment will be disrupted for a few minutes; but, it
will be restored automatically.
WARNING!!!
Make sure that the correct configuration file is
downloaded to the correct Control module. An
incorrect configuration file will lead to Control
module or network failure.
WARNING!!!
Make sure that you have successfully downloaded the
configuration file before conducting an Update. Otherwise
the Control module will switch to an empty ROM that
may cause Control module failure.
5. Click [Update] to activate the new equipment configuration file. Click [Execute] to start the
operation. *[Update] Button is only available when MAINT is ON.
NOTE
Switch ON maintenance mode first before executing
Download Equipment Configuration File.
35
Submission Prohibited ROI-S05593
NEC Internal Use Only
NOTE
The connection to the selected NE will be lost a few
minutes and will automatically re-connect.
6. Click [Close] when done.
36
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.16 Maintenance
There are several maintenance control items that can be executed in the maintenance menu. The
function of each control is as follows.
MAINT: To switch Maintenance mode to ON
TX Switch: To control the TX switch
(for 1+1 Hot Standby systems only.)
RX Switch: To control the RX switch manually
(for 1+1 systems only)
TX Frequency To Control Transmit (TX) Frequency.
RX Frequency To monitor Receive (RX) Frequency.
Frequency Channel: To monitor Frequency Channel.
TX Mute: To turn off TX power (Local only)
CW (MOD Carrier): To turn on the Continuous Wave for measurements
(Local only)
Main Signal Loopback – 1: Disabled for line input of 150MB INTFC/OPT INTFC
Main Signal Loopback – 2: Disabled for line output of 150MB INTFC/OPT INTFC
IF Loopback: (Local only)
ALS Restart: To set the time of manual restart Automatic Laser
Shutdown (ALS)
LAN Device Reset: To reset LAN Device of Main INTFC or Sub INTFC.
ATPC Manual: To enable the optional setting of manually transmitted
power when the ATPC is in operation.
Linearizer Control: To disable the linearizer function manually
(for Linearizer-systems only)
XPIC FORCED Reset: To disable the XPIC function. (for XPIC systems only)
* These controls are only available when MAINT is ON. (“Switch to Maintenance mode first” is
displayed in case it is set to OFF.)
NOTE
MAINT, TX Mute, CW, Loopback and ATPC Manual will be cleared if the power is
turned off and on or the RESET switch is depressed.
37
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.16.1 Maintenance Menu
To display the Maintenance window:
1. Select Configuration Æ Maintenace in the NE-specific menu bar of the PNMT main
window.
Maintenance Window
(1+1 configuration)
Maintenance Window
(1+1 configuration)
For XPIC systems
38
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.16.2 Selecting Maintenance mode
To switch the NE to maintenance mode:
1. Click [MAINT] in Maintenance window.
2. Select on ON/OFF depending on desired state.
3. Click [Execute] to carry out the command.
4. Click [Close] when finished.
CAUTION
When Loopback is changed from the default setting (OFF)
to ON, a confirmation message appears.
39
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.16.6 Main Signal Loopback -2
This loopback is created at the line output of 150MB
INTFC/OPT INTFC.
To set the Main Signal Loopback-2:
1. Click [Main Signal Loopback-2] in the
Maintenance window.
2. Select ON to activate the loopback.
3. Click [Execute] to activate the loopback.
4. Click [Close] when finished.
CAUTION
When Loopback is changed from the default setting
(OFF) to ON, a confirmation message appears.
40
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.16.9 Selecting TX Mute status
TX power of the ODU is switched off when TX Mute is ON. This should be OFF in normal
operation.
To change the TX Mute status:
1. Click [TX Mute] in Maintenance window.
NOTE
Switch maintenance mode ON first
before executing TX Mute.
NOTE
The message TX mute ON will affect visibility of the
wireless connection. The connection to the opposite
Pasolink will be lost a few minutes.
4. Click [Close] when finished.
2.16.10 TX Frequency
Control the current RF transmitted frequency and consequently its pair receiving frequency.
(See 2.17 Equipment Setup.)
2.16.11 RX Frequency
Display the current RF receiving frequency used by the ODU.
(See 2.17 Equipment Setup.)
NOTE
Switch maintenance mode ON first before
executing CW.
NOTE
41
Submission Prohibited ROI-S05593
NEC Internal Use Only
The message CW ON will affect visibility of the wireless
connection. The connection to the opposite Pasolink will
be lost a few minutes.
4. Click [Close] when finished.
42
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.16.16 LAN Device Reset
The LAN Device can be reset using this function
NOTE
Resetting the LAN will affect the traffic. The connection to
the selected NE will be lost for a few minutes and will be
automatically reconnected.
43
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.17 Equipment Setup
Main signal, ODU and CTRL portion can be monitored and controlled in this window.
NOTE
If each setting item of "Equipment Setup" is changed when equipment is in-
service mode, the service will be interrupted.
44
Submission Prohibited ROI-S05593
NEC Internal Use Only
45
Submission Prohibited ROI-S05593
NEC Internal Use Only
46
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.17.2 Setup
To setup the ODU and IDU parameters:
1. Click [Setup] in the Equipment Setup window.
XPIC* XPIC – sets the XPIC function mode to Master, Slave, or Not Used (disabled).
Adjacent Channel – sets the adjacent channel to ACAP or ACCP mode Note: when an
adjacent channel exists, ACAP must be selected.
ODU TX Frequency – sets the RF transmit frequency and consequently the RF receive
frequency of the ODU
If frequency Channel file is previously registered, frequency setting by Channel name is
available. Refer to “Frequency Channel” screen shown as below.
TX Power Control – method used by the ODU for power control functions can be set
here. Either Automatic Transmit Power Control (ATPC) or Manual Transmit Power
Control (MTPC) can be selected.
IDU Redundancy – This function Is available only for 1+1 systems. Hot Standby or Twin-
Patch systems configuration can be set using this function.
Main INTFC – the main interface of the IDU can be selected here. The available
interfaces are STM-1(Optical), STM-1(Electrical), and STM-1(Optical SF) or
10/100BASE-T.
TX Switch Type – The type of TX Switch in 1+1 Hot Standby configuration can be
set up here. RF Switch or Mute can be selected. (Only available on 1+1 HS, except
XPIC systems)
Frame ID – used to synchronize the TX and RX frames of opposing NEs in the hop.
The frame ID can be set from 1 to 8.
*: for XPIC-systems only
47
Submission Prohibited ROI-S05593
NEC Internal Use Only
3. Click [Execute] to activate the new set of values.
CAUTION
The message about changing the TX frequency will cause
the wireless connection to appear.
4. Click [Close] when finished.
NOTE
1. In XPIC systems, TX Power Control of slave equipment is not configurable. The slave
equipment follows the TX Power Control setting of the master equipment.
2. In XPIC systems, if TX Power Control of master equipment is changed, the TX Power
Control of the slave equipment is also changed. This will be displayed on the event log
(two lines).
2. Select Channel and click [OK], then TX and RX frequency corresponding to the channel will
be set.
Frequency channel file format is csv, including channel name, TX frequency and RX
frequency.
Examples
Ch1, 7442.000, 7603.000
Ch2, 7603.000, 7442.000
48
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.17.4 Editing the NE Name
To edit the NE name:
1. Click [NE Name] in Equipment Setup window.
2. Enter new PASOLINK name in the NE Name dialog box. A
maximum of 32 characters can be used.
3. Click [Execute] to change to new name.
4. Click [Close] when finished.
49
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18 Provisioning
The main interface (MAIN INTFC), overhead (OH), MTPC and ATPC can be set in this window.
50
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.2 MAIN INTFC
This function enables you to set the STM-1 Optical and 10/100Base-T Setting.
STM-1 Optical function enables you to set the ALS and its properties. The ALS or Automatic
Laser Shutdown is a function available in the IDU that cuts the laser emission on the main
interface after the STM-1 LOS has been activated for a certain length of time.
51
Submission Prohibited ROI-S05593
NEC Internal Use Only
Setting the PORT 1/2
In the Setup window, the configurable items are shown and described in the table below:
Port Mode – sets the type of the speed and the duplex of each port.
Setting The available types are AUTONEG (AUTO-MD1/MDIX), 10M-HALF(MDI),
10M-FULL(MDI), 100M-HALF(MDI), 100M-FULL(MDI), 10MHALF(MDIX),
10M-FULL(MDIX), 100M-HALF(MDIX) and 100MFULL(MDIX).
Flow Control – specify the Flow Control of each port.
Collision Report – set the status of each port to report when collision occurs.
52
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.3 Overhead (OH) Assignment
2.18.3.1 OH Assignment Type
The OH can be either set at factory default (Easy) or customized (Custom) according to user
requirements.
To set the OH Assignment type:
1. Click [Assignment] in the Provisioning window.
2. Select the type of OH assignment that will be employed.
3. Click [Execute] to activate the setting.
4. Click [Close] when finished.
2.18.3.2 Direction
To set the direction:
1. Click [Direction] in the OH Assignment table.
2. On the ensuing table, you will be able to select the
direction for the V11-1 and V11-2 interface.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
53
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.4 Manual Transmit Power Control (MTPC) Status
When the MTPC is selected over ATPC the buttons on this section will become sensitive and the
MTPC parameters can be set. The MTPC has four (4) parameters:
MTPC TX Power
RX Threshold
And Additional Attenuation
The procedure for setting these parameters will be presented in this section.
NOTE
1. In XPIC systems, MTPC status of slave equipment is not configurable. The slave
equipment follows the MTPC status setting of the master equipment.
2. In XPIC systems, if MTPC status of master equipment is changed, of the MTPC status of
slave equipment is also changed. This is shown in the event log (two lines). This is
normal operation.
2.18.4.2 RX Threshold
Set the threshold value of the receiving level. When the received level converge on the preset value
of the threshold the TX power is controlled by sending control signals in the Radio Frame
Complementary Overhead (RFCOH).
To set the RX threshold:
1. Click [RX Threshold] in the MTPC Status
section of the Provisioning window.
2. Set the power (dB) in the following window.
You can highlight the input field and enter
the dB value using the keypad in the input
field.
3. Click [Execute] to activate the new preset value.
4. Click [Close] when finished.
54
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.4.3 Additional Attenuation
If the transmission length of the wireless segment is short, additional span attenuators can be set in
the ODU. The additional attenuation can be set from 0 to 5 dB.
To set the additional attenuation:
1. Click [Additional Attenuation] button in the MTPC Status section of the Provisioning
window.
2. Set the attenuation (dB) in the ensuing
window. You can highlight the input
field and enter the dB value using the
keypad in the input field
3. Click [Execute] to set the attenuation.
4. Click [Close] when finished.
55
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.5.2 TX MIN Power
When the ATPC is in operation, the minimum transmission power (dB) can be set using this
function.
To set the maximum transmission power in ATPC:
1. Click [TX MIN Power] in the ATPC Status section of the Provisioning window.
2. Set the power (dB) in the ensuing window.
You can highlight the input field and enter
the dB value using the keypad in the input
field.
3. Click [Execute] to set the minimum ATPC
TX power.
4. Click [Close] when finished.
2.18.5.3 RX Threshold
Set the threshold value of the receiving level. When the received level converges on the preset
value of the threshold the TX power is controlled by sending control signals in the Radio Frame
Complementary Overhead (RFCOH).
To set the RX threshold:
1. Click [RX Threshold] in the ATPC Status section of the Provisioning window.
2. Set the power (dB) in the ensuing window.
You can highlight the input field and enter
the dB value using the keypad in the input
field.
3. Click [Execute] to activate the new preset
value.
4. Click [Close] when finished.
NOTE
When modulation type is 128QAM, RX Threshold is set to the threshold value of
receiving level.
If system quality can deteriorate by -60 dBm or less, RX Threshold should be set between
-60 dBm and -30 dBm.
56
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.5.5 ODU ALM Mode
This item defines the ODU transmit power level when ATPC is under abnormal operation (for
example, when the collection of the ATPC information from the opposite station can not be
performed or when MAX power output is continued).
To set the ODU ALM mode:
Click [ODU ALM Mode] in the ATPC status section of the Provisioning window.
Select the action of the ODU in case of IDU communication failure. For MTPC, only Hold mode is
available.
1. Click [ODU ALM Mode] in the MTPC Status section of the Provisioning window.
2. Select the action of the ODU in case of IDU communication failure. For MTPC, only Hold
mode is available.
MAX: Select this to cause the ODU to transmit at the
ATPC Maximum PWR setting.
MIN: Select this to cause the ODU to transmit at the
ATPC Minimum PWR setting.
Hold: Select this to cause the ODU to maintain the
transmit power at times of failure.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
2.18.6 SW Priority
2.18.6.1 TX SW Priority
This function specifies that the use priority of No.1 unit is higher from a TX viewpoint than No.2
or those of the same priority. In case the switch in front panel of IDU is explicitly set to No.1 or
No.2, usage obeys the switch, in which case this function is ignored. This function is also ignored
when the TX switch mode is manually set to No.1 or No.2
from PNMT. It is available when both IDU and PNMT are in
auto TX switch mode. Priority No.1 makes TX switch turn to
No.1 when TX switch mode is changed to auto from manual,
even if TX switch is set to No.1 or No.2 before changing of the
switch mode. Non-Priority makes TX switch not change when
TX switch mode is changed to auto from manual even if TX
switch is set to No.1 or No.2 before changing of the switch
mode.
2.18.6.2 RX SW Priority
This function specifies that the use priority of No.1 unit is higher from a RX viewpoint than No.2
or those of the same priority. In case the switch in front panel of IDU is explicitly set to No.1 or
No.2, usage obeys the switch, in which case this function is ignored. This function is also ignored
when the RX switch mode is manually set to No.1 or No.2
from PNMT. It is available when both IDU and PNMT are an
auto RX switch mode. Priority No.1 makes RX switch turn to
No.1 when RX switch mode is changed to auto from manual
even if RX switch is set to No.1 or No.2 before changing of
the switch mode. Non-Priority makes RX switch no-change
when RX switch mode is changed to auto from manual even if
RX switch is set to No.1 or No.2 before changing of the switch
mode.
57
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.7 Sub INTFC
There are 2 optional sub interfaces available in the PASOLINK+ system. On this section, these
sub-interfaces can be defined and specified accordingly.
2.18.7.1 Defining the SUB INTFC
To set the type of sub interface mounted in the IDU:
1. Click [SUB INTFC] in the Provisioning window.
2. Select the type of interface used from the ensuing window. If there are no WS and LAN card
plugged into the IDU, “Not used” must be selected.
58
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.7.3 WS Line Length
To specify the WS line length:
59
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.9 BER Threshold
The BER in the PASOLINK+ system is monitored in 3 sections – (1) the MUX section, (2) the
DMR section and the (3) Radio section. The Radio section is available in 1+1 systems only and is
used for switchover function. The figure below illustrates these sections:
The MUX and DMR section BER is measured in terms of Signal Degrade and E-BER. Signal
Degrade is triggered when the BER is worse than the preset threshold (1E-6, 1E-7, etc.). Excessive
BER (E-BER) occurs when the BER is worse than the preset threshold (1E-3, 1E-4, or 1E-5).
The radio section, on the other hand, monitors the BER for switchover purposes. When the BER
becomes worst than the preset value of the Low BER (RX Switch) the RX is switched to the other
system in a 1+1 configuration. In a similar manner, when the BER becomes worse than the preset
value for High BER, it is switched to the other system.
The preset value mentioned above is called the BER Threshold. The BER threshold can be set in 6
points: (1) Signal Degrade (MUX), (2) E-BER (MUX), (3) Signal Degrade (DMR), (4) E-BER
(MUX), (5) Low BER, and (6) High BER. Low BER and High BER, however, are only available
in 1+1 systems.
60
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.9.2 E-BER (MUX)
To set the E-BER Threshold for the MUX section:
1. Click [E-BER (MUX)] in the Provisioning
window.
2. Select the preset value wherein the E-BER will
be triggered.
3. Click [Execute] to activate the new threshold.
4. Click [Close] when finished.
61
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.18.9.6 Low BER (Radio) [for 1+1 systems only]
To set the Low BER:
1. Click [Low BER] in the Provisioning window.
2. Select the preset value wherein the E-BER will be triggered.
62
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.19 Link Performance Monitor
The following performance items can be monitored according to the G.826 recommendation:
Out of Frame Second (OFS) – the total number of seconds the "out of frame" condition
is generated in 15 minute-blocks.(OFS is applied to the Total only)"
Errored Second (ES) – the cumulative time in which more than one B1 error pulse per
second was detected
Severely Errored Second (SES) – the cumulative time in which the BER of one second
period exceeded 10E-3.
Unavailable Second (UAS) – the cumulative time in which the unit remained
inoperative
Background Block Error (BBE) – the sum of the B1 background block error
Red color in Performance monitor window indicates the occurrence of performance items
exceeding the threshold value. The threshold values can be set in Threshold window. The detailed
daily performance data can be seen by clicking on the [Detail] button.
63
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.19.2 Threshold Setting
To set the threshold values:
1. Click [Threshold] in the Summary Link Performance Monitor window
2. Select the performance item that is to be configured on the table shown above. The G.826
measure becomes available for setting when selected. The arrow buttons on the left-hand side
of the field indicate this availability.
3. Set the value when the alarm is to Occur and when the alarm is to Recover in the appropriate
fields. This measure will issue an alarm status when it reaches the alarm occur value and will
issue an alarm clear status when it reaches the recover value set in the threshold table.
4. Click [Execute] to activate the new settings.
5. Click [Close] when finished.
64
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.19.3 Link Performance Monitor (Daily Data) window.
This window contains the Link Performance data of the past 8 days.
To view the Link Performance Monitor (Daily Data) window:
1. Click [Detail] in the Link Performance Monitor window.
Refresh
Save
65
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.19.4 Link Performance Monitor (15-min Data) window
To view the 15-min Data:
1. Click of the target date in Link Performance Monitor (Daily Data) window to display the
detailed 15-min performance data.
Refresh
Save
66
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.20 NE Stored Log
The Event Log window displays the date/time when the event or command was received, item and
status.
67
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.21 Version Tab
The inventory information of the ODU and the IDU can be viewed using this function.
68
Submission Prohibited ROI-S05593
NEC Internal Use Only
2.22 License import
2.22.1 License import
To update the license file:
1. Go to Help Æ License in menu bar of PNMT main window.
69
Submission Prohibited ROI-S05593
NEC Internal Use Only
3. Click […] to locate the new license key file.
4. Indicate a License key file (i.e. License.key) that will be associated to PNMT. Select a
License key file and click [Open] to continue.
70
Submission Prohibited ROI-S05593
NEC Internal Use Only
5. After verifying the path to the License key file is correct, click [Next] to proceed.
6. The progress of checking the license file will be displayed. If no error is encountered
in the checking of the license file, click [Next] when the button becomes available.
71
Submission Prohibited ROI-S05593
NEC Internal Use Only
7. Verify the contents of the license that you applied.
72
Submission Prohibited ROI-S05593
NEC Internal Use Only
3 APPENDIX A: RESTRICTION
The restrictions of PASOLINK+ STM-1 equipment are shown below.
For details, please refer to the equipment manual.
1. When the different type of IDU is used at opposite side, the connection is not established.
2. The connectable combination of ODU and IDU is as follows.
9: Available, –: Not Available
ODU
HG SHG UHG SHG3 UHG3
STM-1 / 32QAM 9 9 9 9 9
STM-1 / 128QAM – 9 9 9 9
IDU
(1+0/1+1) STM-1 / 128QAM / XPIC – – 9 – 9
STM-1 / 128QAM /
– – – 9 9
Linearizer
Note: In 1+1 system, two set of ODU with the same grade are only connectable with IDU.
3. For only XPIC systems only, equipment with XPIC master function cannot be used in
combination with others without XPIC master.
4. For SUB INTFC only, the H1010A LAN CARD cannot be used in combination with a
G7906A LAN CARD on the opposite side, and vice versa. Please be sure to use in
combination with the same type of LAN CARD.
73