Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
3K views
38 pages
As 4284 2008
australian standard
Uploaded by
Luiz Carlos
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save AS_4284_2008 For Later
Download
Save
Save AS_4284_2008 For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
0 ratings
0% found this document useful (0 votes)
3K views
38 pages
As 4284 2008
australian standard
Uploaded by
Luiz Carlos
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save AS_4284_2008 For Later
Carousel Previous
Carousel Next
Download
Save
Save AS_4284_2008 For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
Download now
Download
You are on page 1
/ 38
Search
Fullscreen
18 J Paraggio on 06 Aug 2008. t user personal user cence only. Stocage, eistibuton or use on network prohibited Licensed to AS/NZS 4284:2008 Australian/New Zealand Standard™ Testing of building facades Fit published as ASINZS 4224 1005, ‘Second adton 2008 COPYRIGHT © Standards Australia/Standards New Zealand All rights are reserved. No part of this work may be reproduced or copied in any form or by ‘any means, electronic or mechanical, including photocoaying, without the written permission ofthe publisher Jointly published by Standards Australia, GPO Box 476, Sydney, NSW 2001 and Standards New Zealand, Private Bag 2429, Wellington 6020 ISBN 0 7937 8619 7Licensed to Melinda J Paraggio on 06 Aug 2008, 1 user personal user licence only. Storage, dstibuton or use on network proibite. ASINZS 428422008 2 PREFACE, This Standard was prepared by the Joint Australia/New Zealand Standards Committee BD-080 on Curtain Walls to supersede AS/NZS 4284:1995 The Standard is based on “Specification for the performance testing of building facades by the SIROWET method” published by CSIRO, Division of Building, Construction and Engineering now it is known as Manufacturing and Infrastructure Technology. This Standards is derived from publication by the CSIRO on the method of facade testing developed by the CSIRO and known as SIROWET. These publications are the following: () ‘The SIROWET Rig, for testing weatherproofess of building facades’ by N.G. Brown and E.R. Ballantyne, CSIRO Division of Building Research 1975, (ii) ‘Specification for the performance Testing of Building Facade by the SIROWET Method’, January 1990, Division of Building, Construction & Engineering, CSIRO— Australia, (iii) ‘The SIROWET Method; Specification for the Performance Testing of Building Facades by the SIROWET Method’, June 1992 ISBN 0643 050930. This specification (TR92/6) is effective from 30 June 1992 and supersedes (TR 90/2) dated February 1990. Consideration has been given to maintaining compatibility with NZS 4211:1985, Specification for performance of windows and with Amendment No. 3 which converts the carlicr working stress basis to limit state design requirements. It should be noted that the water test pressure calculated in NZS 4211 Amendment No 3 is based on an alternative serviceability wind pressure definition and not equivalent to serviceability pressure determined in AS/NZS 1170.2. ‘The objective of this Standard is to provide those persons or organizations involved with the specification, design, purchasing and construction of building facades with a method for determining the performance of a building facade under wind and other optional loadings. This test method is applicable to complete facades and is intended to assess the overall system performance and interaction of the various facade components, The Committee has made a number of significant changes and additions to the original SIROWET method and these include the following: (a) Change to limit state principles from working stress. (b) Addition of optional seal degradation, seismic and building maintenance unit (BMU) restraint tests, (©) Aditi ‘Test pressures nominated in the Standard represent minimum default values that should be applied to the test sample; however, selection of pressure values should be based on the proposed usage of the structure, its exposure conditions and of the expected performance of the facade. n of several appendices, including a pro forma for test loads and limits‘Storage, distibution or use on network prohibited. Licensed to Melinda J Paraggio on 06 Aug 2008. 1 user personal user lence on 3 ASINZS 4284:2008 For high rise residential and commercial building facades (buildings typically greater than 25 m) or at particularly exposed sites that incorporate curtain wall, strip windows, opening window sashes, sliding doors, bifolding doors and the like, the methods of test described in this Standard are applicable to prove performance of the system. Facade elements in these situations can be subjected to the same environmental factors such as a continuous facade on an office building—particularly wind-driven rain. The non-uniform nature of wind- driven rain has led to the adoption in this Standard of the cyclic pressure water test and the SIROWET method before it. Appropriate additional testing parameters, such as those described in Table 2.2 of AS 2047—1999, Windows in buildings—Selection and installation and AS 4420.3—1996, Windows—Methods of test, Method 3: Operating force test as well as the torsional rigidity of building elements as covered in Clause 13 of NZS 4211:1985 Specification for performance of windows, should also be considered for relevant elements. The term ‘informative’ has been used in this Standard to define the application of the appendix to which it applies, An appendix is only for information and guidance,ieence only. Storage, distibuion or use on network prohibited Licensed to Melinda J Paregglo on 05 Aug 2008. 1 user personal us ASINZS 428422008 4 1 SGOPBsasissassse 2 REFERENCED DOCUMENTS. 3. DEFINITIONS. 4 NOTATIONS... S PRINCIPLE 6 APPARATUS... 7 SAMPLE PREPARATION 8 PROCEDURE... a 9 PERFORMANCE REQUIREMENTS: 10 TEST REPORT. APPENDICES A INFORMATION TO BE SUPPLIED BY SPECIFIER, B SAMPLE PREPARATION........ C STRENGTH TEST AT ULTIMATE LIMIT STATE LOADING. 00. D AIR INFILTRATION TESTING... E WATER PENETRATION TESTING wc. F SEISMIC TESTING wren CONTENTS.Licensed to Melinda J Paragglo on 06 Aug 2008.1 user personal user licence ony. Storage, distribution or use Gn network prohibited s ASINZS 4284:2008 STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND Australian/New Zealand Standard Testing of building facades 1 SCOPE ‘This Standard sets out a method for determining the performance of a representative building facade under simulated conditions of loading. This Standard may be applied to all types of facades including low- and high-rise, commercial, industrial and residential buildings. Tests include displacement of the facade or prototype, water penetration and structural integrity at ultimate limit state as well as optional tests, including BMU restraint, seismic loading and seal degradation, This test method is applicable to prototype testing in a test facility and on-site testing. 2 REFERENCED DOCUMENTS The following documents are referred to in this Standard: AS 1170 Structural design actions 1170.4 Part 4: Earthquake loads ASINZS 1170 Structural design actions 1170.0 Part 0: General principles 1170.1 Part I: Permanent, imposed and other actions 1170.2 Part 2: Wind actions NZS 1170 Structural design actions 1170.5 Part 5: Barthquake actions—New Zealand aun Specification for performance of windows ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories 3. DEFINITIONS For the purpose of this Standard, the de! 3.1 BMU ions below apply. Building maintenance unit, 3.2, Framing members The elements, such as mullions and transoms that support facade panels 3.3. Specifier The person or party responsible for the facade Specification, nominating the use of this Standard, the test sample, sequence, pressures and performance criteria. 3.4 Test facility Bither a laboratory or any other facility registered by an accredited-testing agency in accordance with ISOMEC 17025. copyRIGHTLicenses to Melinda J Paraggio on 06 Aug 2008, 1 user personal user licence only. Storage, cistron or use on network prohibited ASINZS 4284:2008 6 3.3. Uncontrolled water Any leakage that is not contained and drained away during the water spray operation and for $ min after the water spray has stopped during which time there is zero air pressure differential on the facade, 4 NOTATION The following symbols are used in this Standard Dz = average of net end displacements, in millimetres Dy = maximum displacement of member (generally at midspan), in millimetres d, _ ~ seismic test displacement amplitude at the serviceability limit state, in millimetres, 4d, = seismic test displacement amplitude at the ultimate limit state, in millimetres K, = deflection amplification factor, in millimetres M = overturning moment, in kilonewton metres n= number of cycles in the seismic test Ry = structural response factor S-_= span of member between points of support (transducers), in millimetres T = period of the seismic cycle, in seconds positive serviceability test pressure, in millimetres 5 PRINCIPLE A sample of the building facade forms one face of an externally mounted chamber and is sealed at its perimeter and then successively subjected to a structural test, a water penetration test and a strength test. NOTES: 1 Additional tests requested by the Specifier may include an air infiltration test, seismic loading by in-plane displacements, a simulated seal degradation test and a BMU restraint load test, 2. For information on sample preparation, see Appendix B. 6 APPARATUS ‘The following apparatus is require (@) An externally mounted chamber of a size to fit to the test sample of the building facade. The fit shall be such as to seal the perimeter of the test sample against air and water penetration. NOTE: The use of an internally mounted pressure box is suitable for all static pressure tests but may not adequately demonstrate water penetration in pressure-equalized systems in the eyelie pressure test. (b) A reversible air pump with controls to pressurize and depressurize the chamber (©) Water sprays positioned so that when the sprays are in operation, the extemal face of the test sample is covered with water. (@) Displacement transducers capable of measuring deflections to an accuracy of 40.2 mm, (@) An orifice plate or laminar flow elements or other airflow measuring device calibrated to a traceable standard, coPyRIGHTLicensed to Metinda J Paraggia on 06 Aug 2008.1 user personal user oan only. Storage, cisbutlon or use on rtwork prohibited () A manometer capable of measuring air pressure to an accuracy of 2% of measuring range. The manometer used during the cyclic water test shall have a fast response time of at least 0.05 s. 7 SAMPLE PREPARATION 7.1 Test sample The sample, with components, shall be representative both in size and shape of the facade of the building. Vertical and horizontal movement joints shall be included in the test sample, The joints shall be set on the sample within the design joint width including tolerances. ‘The materials of the test sample (glass, aluminium, stone, reinforced concrete, sealants, gaskets, etc.) shall be of the same type and size, have undergone the same method of construction, and have the same details, flashing and anchorage as the building facade, If not an actual on-site representative sample of the wall of the building, the test sample shall be mounted and sealed into a simulated building frame in the same manner and by the same fixings that are intended to attach the facade to the building structure. The support frame shall be of similar stiffness to the supporting building structure NOTE: For discussion of the supporting structure, refer to Appendix B. Simulated floor slabs and spandrel beams shall be to actual depth if, for example, in curtain walls, the air seal is connected to the slab. The internal finishes and linings shall be installed where they contribute to the air seal, The air seal of the test sample shall be continued to the air seal of the test chamber. All framing members and other interconnected joints in the facade shall be sealed at the sample boundaries. NOTE: This is to minimize the effects that the surrounding construction will have on the test performance of the sample. All pressure equalization and drainage openings in the test sample shall be left open for the duration of testing ‘NOTE: Transparent viewing panels (or other means of observation, such as an optical fibre probe) should be provided so that the performance of the test sample in areas that are not readily seen can he observed. They should be sized and sited to have a negligible minimal effect on the water and structural performance of the test sample 7.2 Drawings Shop drawings shall be supplied to the test facility before installation of the test sample. These drawings shall include the following: (a) Test sample elevation and vertical and horizontal sections. (>) Typical details of framing members and facade panels (including intersections of members). (©) All fixing brackets and support details. (@)_ Extent and type of sealants. (e) _ Size, position and number of pressure equalization and drainage openings, ® Complete building in and blanking off details around the perimeter of the sample, including the chamber details where significant to sample performance. (2) Location of transparent viewing panels if used. (bh) Method of installation, (Location of displacement transducers. COPYRIGHT ASINZS 4284:2008Licensed to Melinda J Paraggio on 06 Aug 2008. 1 user personal user licence ony, Storage, distribution or use on network prohibited ASINZS 42842008 8 8 PROCEDURE 8.1 Test sequence BALL General ‘The sample shall be subjected to the tests in Items (a), (b), (d) and (g). The other tests shall be carried out only if specified. The test sequence shall be as follows: {a) Preliminary tests, (b) Structural test at serviceability limit state. (c) Air infiltration test. (d) Water penetration test by static pressure followed by cyclic pressure test. (2) Seismic test at serviceability limit state displacement (includes subsequent water penetration test) (f) BMU restraint test. (g) Strength test at ultimate limit state {h) Sein ic test at ultimate limit state displacement. (i) Seal degradation test. B.L.2 Variation of test sequence or retesting Where a variation of the test sequence is required, or if the test sample requires modification to gaskets, joint seals or drainage details to enable it to pass either the air infiltration ot the water penetration test, both tests shall be repeated in full. Before retesting, the full positive and negative structural-test pressures (JV,) shall be applied to the test sample for 2 min each. 8.2. Prelit 8.2.1 General The tests in Clauses 8.2.2 and 8.2.3 shall be conducted before the structural test. Before prototype testing the information required in Appendix A shall be submitted by the Specifier. inary tests 8.2.2 Static pressure The test sample shall be subjected to the positive and negative SLS design wind pressures. ‘These pressures shall be maintained for 10 s at the positive requirement followed by 10's at the negative requirement 8.2.3 Water Preliminary water tests shall be conducted under static and cyclic pressures in accordance with Clauses 8.5 and 8.6, 8.3. Structural test at serviceability limit state 8.3.1 Structural-iest pressures The structural-test pressures (I¥,) are the positive and negative SLS design wind pressures. They shall be calculated in accordance with AS/NZS 1170.0 and AS/NZS 1170.2. and include all local pressure factors and internal pressures relevant to the location of the sample on the building, The minimum serviceability requirements shall be for an annual probability of exceedance of 1/20 (0.05). NOTE: Information on structural and strength test at ultimate limit state loading is given in Appendix C. COPYRIGHT9 ASINZS 4284:2008 8.3.2 Location of the displacement transducers The framework to support the displacement transducers shall be rigidly fixed independent of the test sample. NOTE: The building frame (actual or simulated) is not part of the test sample, Displacement readings shall be taken on the test sample at designated framing members, facade panels and window locations that would represent actual structural movement Displacements shall be taken, at least, at the ends of the framing member or between fixings and at midspan, and also below and above (or to the left or right of) movement joints of framing members and across the shortest span of the largest panel or glass pane included in the test sample. NOTE: Where members of facade framing systems are not simply supported over a single span, the points of maximum defleetion are unlikely 10 fall midway between the support brackets connecting the facade to the building. In these cases the points of maximum deflection should be identified by structural analysis and displacement readings taken at these points Sufficient displacement transducers shall be located at the fixing brackets so that any differential movement between the various components and the support structure will be identified. The location of all displacement transducers shall be nominated or approved by the Specifier 8.3.3 Pressure loading sequence Displacements shall be measured at all pressure (positive) and suetion (negative) sequence steps by calibrated displacement transducers. The loading sequence during test (as shown in Figure 1) consists of three modes and shall be as follows: : g : 5 5 g 5 (2) An initial pressure differential equivalent to either the positive or the negative structural-test pressure shall be applied against the external face of the test sample for a period of 2 min which shall be taken as a settling/take-up period, () The differential pressure shall be removed and the zero position of the transducers recorded after 2 min of zero pressure (see Figure 1, zero stage Z1). (©) Differential pressures in the same direction as in Item (a) shall then be applied to the external face of the test sample in not less than five approximately equal steps, until the pressure reaches the structural test loading. The pressure shall be held at each step for at least | min before the displacements are recorded. (4) ‘The differential pressure shall be removed and the zero position of transducers recorded after 2 min of zero pressure (sce Figure 1, zero stage 22). (c) The structural-test loading shall be applied again to the external face of the test sample and maintained for at least I min, The differential pressure shall then be reduced in the same number of steps as the increasing pressure regime ((see Item (c)). The pressure shall be held at each step for at least | min before the displacements are recorded. Also, the zero position of the transducers shall be recorded after 2 min of zero pressure (see Figure 1, zero stage Z3). (8 The procedure in Items (a) 10 (c), inclusive, shall be repeated using the opposite structural test design loading, (g) The procedure in Items (a) and (b) shall be repeated using the initial differential pressure. NOTE: Items (b) to (¢) are referred to as Mode 1, Item (f) as Mode 2 and Item (g) as Mode 3 Licensed te Melinda J Paraggio on 06 Aug 2008.1 user personal user ence ony. Si COPYRIGHTLicensed to Melinda J Paraggla on 06 Aug 2008. 1 user personal user cence only. Storage, cstbuton or use on rework prohibited ASINES 4284:2008 10 imal Ava Asoo Ra (4) A : | oe Avo iz Fal z2| za 24 zs ze|_|zz TIME, minutes NOTE; The displacements used for deflectiom/span ratios are based on zer0 deflections at the reference stages 2) and 74. The reducing pressure steps fom 72 10 73 and from Z5 10 Z6 are optional FIGURE 1 TYPICAL STRUCTURAL TEST SEQUENCE 8.3.4 Displacement measurement of spandrel panels If the facade specification requires displacement measurements of spandrel panels which form the exterior face of a spandrel box and the spandrel box is a pressure-equalizing design, a separate test is required. Deflection measurements taken of the spandrel panels during the structural test sequence indicated above shall not be accepted as true readings of spandrel panel deflection, as the spandrel panels may not be under full test load, due to the extent of pressure equalization of the spandrel box chamber. ‘The spandre] panel measurement may be carried out immediately after the structural test sequence has been completed, or any other time before the strength test at ultimate limit, state pressure. Holes shall be installed in the prototype in a location agreed with the testing officer (usually in the back-pan), so that, when the test pressure is applied, the pressure difference will be across the spandrel panel. These holes may be installed before testing and covered for other tests, Deflection transducers may be installed through the holes in the back-pan, to the internal surface of the spandrel panel or to the external surface of the spandrel panel. The loading sequence of structural loadings shall be repeated as shown in Figure 1, taking deflection measurements of the spandrel panels. The test pressure for the spandrel panels, may be reduced in accordance with the porosity provisions of AS/NZS 1170.2. During this test, pressure readings shall be taken both inboard and outboard of the spandrel panel(s) for Which deflection measurements are being taken, to ensure that the pressure differential across the spandrel panel(s) is equal to the agreed spandrel test pressure When the spandrel deflection measurements have been taken and this test is complete, the holes shall be covered, so that the pressure difference in the spandrel box is applied across the back-pan and the prototype is effectively restored to the in-service condition. The hole covers shall be structurally contimuous with the member to which they are attached and any sealant used in the covers is adequately cured before testing is resumed. COPYRIGHTUcensed to Melinda J Paragsio on 06 Aug 2008.1 user personal ser licence ony. Storage, distbution oF use on network prohibited u ASINZS 4284:2008 Calculation of deflection/span ratio Where a framing member of the test sample is effectively supported at its ends only, its midspan deflection and resultant deflection/span ratio under load shall be calculated. The displacement for each transducer at the ends and midspan of the member and cach mode (positive and negative) shall be reduced to a deflection and deflection/span ratio using the relationship— Deflection / span ratio is 1 where S = span of member between points of support (transducers) Dz = maximum displacement of member (generally at midspan) Dz = average of net end displacements The greater of the two deflections in positive and negative modes shall be used in the calculation of the deflection/span ratio for the members and panels. Significant variations in the ratios at the design pressure steps (that is either side of mid-mode steps) shall be noted in the final report. Mode | deflection readings shall be referenced to Z1 and Mode 2 deflection readings shall be referenced to Z4 NOTE: When stack joints are involved in the case of unitized curtain wall mullions, the maximuin displacement may vary from the midspan between the support and the stack joint, In such instances it is recommended the transducer location for maximum displacement be checked with the aid of structural analysis software or design charts (see Figures C1 and C2). 8.3.6 Calculation of successive member displacement The successive displacement of a member is the zero air pressure displacement (relative to the reading after initial take-up) measured during the structural performance test (refer to Figure 1)— (a) between maximum pressures in Mode 1 (stage 22); (b) before take-up in Mode 2 (stage 23); (©) after take-up in Mode 2 (stage 74); (4) between maximum pressures in Mode 2 (stage 25); (©) before take-up in Mode 3 (stage 26); and (0) after take-up in Mode 3 (stage 27), 8.3.7 Calculation of maximum displacement The maximum displacement in Mode! shall be referenced to Z1 and maximum displacement in Mode 2 shall be referenced to Z4. NOTE: Referencing of the made of displacement to the Z4 zero values provides the equivalent member displacement as determined for Mode 1 while maintaining the successive member displacement values ZI to 27. 8.4 Air infiltration test 8.4.1 Test pressure ‘The air infiltration test pressure shall be as specified or taken as +150 Pa and —150 Pa, coPYRIGHTASINZS 428422008 2 8.4.2 Procedure The total air infiltration rates through the test sample and the test enclosure shall be determined by applying both positive and negative test pressures, No further testing shall be required if the air infiltration rates determined on the combined test specimen and test enclosure are less than the purchaser-specified air infiltration rate or the value in Clause 9.3, and there is no requirement for actual infiltration rates through the test specimen. Where the total air infiltration rate is greater than the purchaser-specified air infiltration rates or the value in Clause 9.3, or the purchaser/specifier requires actual air infiltration rates, the face of the test sample shall be sealed airtight by covering it with an impervious film. If this is not practicable, all joints, weepholes and glazing or sealant lines of the test facade shall be sealed with air-impervious tape and the air infiltration rates for the enclosure only determined. The air infiltration rates through the test sample shall be the difference between the total and sealed airflow meter readings at both positive and negative test pressures NOTE: Air infiltration testing is described in Appendix D, 8.5 Water penetration test by statie pressure 8.5.1 Test pressure The water penetration test pressure shall be nominated by the Specifier, or taken as the greater of 300 Pa or 0.3 85.2 Procedure oF use on network profited. The test facade shall be subjected to water sprayed completely and continuously over the exterior face of the test sample at a rate not less than 0.05 L/m’ s (3 L/m? min). ‘At the start of the test, the water spray shall operate for 5 min with zero air pressure differential on the facade. This shall be followed by a further period of 15 min at the test pressure. Observations of the internal surface of the facade shall be carried out during the water spray operation and for 5 min after the water spray has stopped and there is zero air pressure differential on the facade. ‘Any water appearing on the inside surfaces of the facade shall be recorded, with the extent and, if possible, the source of leakage indicated. 8.6 Water penetration test by eyelic pressure 8.6.1 Test pressure ‘The water penetration test using cyclic pressure shall be carried out in three stages and shall take into account the geographical location and exposure of the building and shall be specified by the Specifier, or taken as the following: (a) Stage Lesson 0,15 > W, 100.3 x W, (b) Stage 2 oe sueunananeitatiininnnen D2 Wyt0 0.4 x Ws (©) Stage 3 0.3 W, 10 0.6 * W where W, = positive serviceability test pressure. (Should I, pressure be less than 1000 Pa, use 1000 Pa instead of F, in this Clause.) NOTE: Where buildings are located in Wind Regions B, C and D as defined in AS/NZSI170.2, the test pressures as a function of the serviceability wind pressures (and velocities) should be inereased in line with historic data for wind driven rain at the local area in question, Licensed to Melinda J Paraggio on 06 Aug 2008.1 user personal user cence only. Storage, distibut copyRiGHTLicensed to Melinda J Paraggio on 06 Aug 2008, 1 user personal user lence only. Storage, distrbution o use on network proibites 6 ASINZS 4284:2008 8.6.2. Procedure This test shall be performed upon completion of the test for water penetration test by statie pressure Should the cyclic water penetration test not commence within 30 min of the static water penetration test then immediately before the start of the cyclic test the exterior face of the test sample shall be completely sprayed with water at a rate not less than 0.05 L/m’ s for 5 min with zero air pressure differential on the facade. Water shall be applied continuously and completely cover the exterior face of the test sample at a rate not less than 0.05 L/m’ s while a eyclic positive air pressure is applied to the exterior face for a duration of not less than 5 min. The applied test pressure shall be varied between the specified limits with a cycle time of 3 s to 3s ‘The cyclic pressure shall be recorded on a device capable of recording and graphically displaying the variations in pressure. NOTE: Water gauge manometers and other slow response pressure indicators are unsuitable for this purpose The air pressure differential shall be reduced to zero for 2 min between each stage with the ‘water spray still in operation. Observation of the internal surfaces of the facade shall be carried out during the water spray operation and for $ min after the water spray has stopped during which time there is zero air pressure differential on the facade. ‘The appearance of any water on the inside surfaces of the facade shall be recorded, with the extent and, if possible, the source of leakage indicated. NOTE: Further information on water penetration testing is given in Appendix E. 8.7 BMU restraint test 8.7.1 Test load ‘The load designated in this test shall be ultimate limit state and shall be specified by the Specifier, taking into account the size and operation of the BMU, NOTE: There may be regulatory requirements that will determine the magnitude of the test load 8.7.2. Procedure The BMU restraint unit shall be fitted to a specified restraint point. A lanyard and clip or other restraint system as specified for use shall be attached to the restraint and the other end attached to a cable attached to a load cell reading device and this in turn attached to a cable which is attached to a tensile loading device applying the required load. The load shall be applied in three stages, as follows: (a) The restraint shall be subjected to a tensile load applied orthogonally and horizontally. to the sample, and applied for a minimum of 10 s. (b) The restraint shall be subjected to a tensile load applied horizontally to the left of the anchorage point in the plane of the sample, This load shall be applied for a minimum of 10s. (c) Stage (b) shall be repeated with the load directed to the right of the anchorage point. 8.8 Structural test at wl sate limit state 8.8.1 Test pressures The strength test pressures shall be the facade positive and negative ultimate limit state wind pressures calculated in accordance with AS/NZS 1170.0 and AS/NZS 1170.2 and shall include all local pressure factors and internal pressures relevant to the location of the sample on the building. coPYRIGHTance ony, Storage, dierbution or use on network prohibit, Licensed to Melinda J Peragaio on 06 Aug 2008, 1 user personal user ASINZS 4284:2008 u 8.8.2 Procedure The test sample shall be subjected to positive and negative strength test pressures. Each strength test pressure shall be maintained on the test sample for a period of 10 s. The load period from zero to ultimate limit state pressure shall be 50 5 to 60 s. ‘The sample shall be inspected at the end of each of the positive and negative pressure stages. Record all incidences of non-linear deflection and/or collapse 8.8.3 Spandrel panel If the facade specification requires a structural test at ultimate limit state spandrel panels shall be tested in a repeat structural test at ultimate limit state procedure. Follow the set-up requirements indicated in Clause 8.3.4. Repeat the procedure indicated in Clause 8.8.2 with pressure transducers which measure the pressure difference inboard and outboard of the spandrel panels. The number of spandrel panels instrumented is to be agreed with the involved parties before the test. The structural test at ultimate limit state for the spandrel panels may be carried out either before or after the structural test at ultimate limit state for the other prototype members and components. 8.9 Seis test 8.9.1 Test displacement The sample shall be displaced in the plane of the facade sample for n eyeles at a period T, for distance of 4d, or td, mm from the original setting position. ‘The values of n, 7 and d, ot d, shall be specified and based on the serviceability and ultimate limit states appropriate to the geographical region. The appropriate values of d, at serviceability and dy at the ultimate limit state seismic displacements shall be determined by the building structural designer. 8.9.2 Procedure One of the reaction beams shall be selected by the Specifier as a seismic loading floor. This beam shall be capable of sliding back and forth to simulate lateral seismic motion, The facade support brackets shall be attached to the moveable beam. Lateral displacements of the sample shall be measured as the relative displacement between the lateral fixed support and moveable beam. The mechanism to move the beam shall be of sufficient strength to react to the required test period. Inspect and report the condition of the prototype after the completion of all the cycles. Serviceability limit state displacement test is first carried out, followed by a eyclic water penetration test, in accordance to Clause 8.6. ‘The ultimate limit state displacement test may be carried out before or after the ultimate limit state structural test NOTES 1 No water testis required after the seismic test at ultimate limit state displacements. 2 Further information on seismic testing is given in Appendix F Seal degradation test ‘The Specifier shall designate areas of the sample where seals are to be removed or cut by Knife to simulate long-term degradation of the sample. All changes to the sample shall be reported, A cyclic water penetration test shall be carried out in accordance with Clause 8.6. copyRiGHTLicensed to Melinda J Paraggio on 06 Aug 2008. 1 user personal user cence only. Storage, dstrbuton or use on network prohibited. 18 ASINZS 4284:2008 9 PERFORMANCE REQUIREMENTS 9.1 General The performance requirements listed in the remaini the absence of alternative performance requirements provided by the Specifier 12 sections of Clause 9 shall be used in All components of the sample are required to remain structurally intact as detailed on test sample drawings with no signs of visible damage or distortion following the structural performance, air infiltration and water penetration tests, 9.2 Structural test at serviceability limit state 9.2.1 Deflection/span ratios When tested to serviceability wind pressures and using the method of ealeulation described in Clause 8.3.5, no framing members shall deflect by an amount greater than span/250 mm. For mullions, the span shall be taken to be the distance between fixing positions, in millimetres, 9.2.2 Successive member displacement The successive member displacement calculated from Clause 8.3.6 shall not exceed 3.0 mm. 9.2.3 Maximum displacement The maximum displacement of a framing member calculated from Clause 8.3.7 shall not exceed 20 mm, or a lower figure specified in the facade specification For frames greater than Sm between supports, the maximum frame displacement shall be agreed with the Specifier, but not more than the limit described in Clause 9.2.1 (see Figure C2, Appendix C). 9.3. Air infiltration test Air infiltration for airconditioned buildings shall not exceed 1,6 Lim's. NOTE: Ifthe total air infiltration of the sample and the test apparatus is less than the value given, the sealing of the test sample may be omitted and the test report should quote the total air infiltration reading of the sample and system, (Refer Appendix D.) 9.4 Water penetration test Under static and cyclic pressures there shall be no leaks. For both the static and cyclic water tests, a leak is considered to occur when one or more of the following occur: (a) Water appears on any inside Surface of the facade and is visible from an dccupied space. (b) Uncontrolled water appears on any inside surface of the facade. (c)__ Water appears that is likely to wet insulation, fixtures and finishes. (4) Water appears in other locations specified as unacceptable by the Specifier. 9.5. Seismic test at serviceability limit state displacement The sample shall pass the eriteria set for the cyclic water penetration test (see Clause 8.6) after the seismie test at the SLS displacements. 9.6 BMU rest int test After the load is released in cach step, any deformation of the sample at or near the loading point shall be recorded, A failure shall be recorded if the BMU restraint becomes unserviceable or separates from the sample, ‘COPYRIGHTLicensed to Melinda J Paraggio.on 06 Aug 2008, 1 user personal user licence nly. Storage, dstibutio or use on network prohibited ASINZS 428422008, 16 9.7 Structural test at ultimate limit state Under structural test at ultimate limit state there shall be no collapse of the test sample. Collapse shal] mean any one or any combination of the following: (a) Disengagement or partial disengagement of any framing member, facade panel or any part thereof. () Failure of any fixings that connect the facade to the building structure. (©) Failure of any stop, locking device, fastener or support which eould allow an opening, light to come open. (4) Repeated breakage of glass resulting in loss of chamber pressure. Glass may only be replaced once before the sample is deemed to have collapsed. (©) Repeated cracking of glass which does not result in loss of chamber pressure. Glass. may only be replaced twice before the sample is deemed to have collapsed. ‘Any permanent distortion of a panel shall be noted and documented in the report. NOTE: At the ultimate limit state load the sample may suffer permanent deformation and might not remain operational. This Clause is intended to protect people in the vicinity of the building should a window collapse under extreme conditions 9.8 Seismic test at ultimate limit state displacement The sample shall not collapse during or after the seismic test at ultimate limit state displacements. Any damage to the seals, members or panels shall be recorded and noted in the report. Collapse shall mean any one or any combination of the occurrences described in Clause 9.1(a) to (4). 9.9 Seal degradation test The sample shall be observed for water penetration after the nominated seals have been altered, ‘NOTE: For domestic buildings in New Zealand it has been found that the removal of 10% of the air seal is appropriate, 10 TEST REPORT 10.1, Preliminary test report ‘The test report can be a separate report from the official test report, or incorporated as part of the official test report. All details of preliminary test(s) shall be included in the preliminary test report, including full details of all modifications/rectifications carried out ‘on the facade test sample prior to the official test 10.2. Official test report ‘The report shall include the following: (a) The name of the project, client and Specifier, sample designer/manufacturer and installer as appropriate, as well as the time and date of the test, the test schedule, the identification of official persons observing the testing, name, location and accreditation of the testing facility and the testing officer with responsibility of measuring and recording data and producing the test report, and reference to preliminary test report(s) issued separately. Completed Appendix A form from the Specifier and a summary of results (b) A Certificate of Identification from the facade designer and manufacturer stating that the facade test sample is a true representation of the facade to be erected on the building and it incorporates identical materials and construction methods. The Certificate shall also include the comprehensive list of drawings, which shall describe the facade test sample, and included in the report. COPYRIGHTsensed to Melinda J Paraggio on 06 Aug 2006. 1 user personal user lence only Storage, distribution or use on network prohibited. © @ (e) ( (® (hy (i) G) () a (mn) @) " ASINZS 4284:2008 A general description of the facade test sample. Drawings of the test sample showing modifications, if any. Test sequence with pressures used in all test. For the structural test, provide for each member— (i) location of all transducers: (ii) _ spans of relevant members, given as measured distances between transducers; (iii) deflection/span ratios; (iv) maximum displacement; (v) a separate zero table, giving readings for Z1 to 27; (vi) successive member displacement; and (vii) a full set of readings in an appendix. For the air infiltration test— (i) the air infiltration through the test sample and the system for each of the air infiltration test pressures; and (ii) an estimation of the test accuracy, based on good laboratory practice. For each of the static and eyclic water penetration tests full details of all leakages, including position extent and timing, Seismic test SLS displacements; the location of the moving support beam, damage to seals, members or panels and changes in movement joint positions and/or sizes, Ultimate limit state test; details of all permanent distortion and collapse. Seal deyradation test; drawings and description of seals altered and observations made during the test. Details of the BMU restrai after loading its position on the sample and observations during and Seismic test ultimate limit state; report as per seismic test SLS. Reference to this Joint Australian/New Zealand Standard, i.e., AS/NZS 4284. COPYRIGHTLicensed to Malinda J Paragglo on 06 Aug 2008. 1 user personal user leance only. Storage, dsinbuon or use on network prohibited ASINZS 42842008 18 APPENDIX. A INFORMATION TO BE SUPPLIED BY SPECIFIER (Normative) ‘The Specifier shall complete this test request form for specific test pressures and limits NOTE: Values specified in the Standard are defaults and the Specifier should refer to Appendices B to F for discussion of the basis of some limits COPYRIGHTnce ony. Storage, cstbution or use on network probed Licensed to Metinds J Paragsio on 06 Aug 2008.1 user personal us 9 ASINZS 428422008 TEST REQUEST FORM Project, Client Specifier Sample designer/manufacturer: Installer Date of test requested Test schedule required: (Cross out those Sections not required—a, b, ©, d and g are mandatory to claim compliance with this Standard, AS/NZS 4284} a—Preliminary b—Structural at SLS c—Air infiltration d—Water at static and cyclic e—Seismic at SLS with water ‘—BMU restraint test 9—Strength at ULS Seismic at ULS |-Seal degradation General description of test sample Drawings of the test sample attached? Y/N Certificate of Identification attached? Y/N Position of any viewing panels for water test noted Y/N COPYRIGHTLicensed! to Meknda J Paraggio on 06 Aug 2008.1 user personal user licence only. Storage, cstbuton or use on network prohibited ASINZS 4284:2008, 20 SPECIFIC TEST REQUIREMENTS Section Test Name Clause Required parameters a Preliminary test 24 SLS pressure 82.2183 Sis) = a Water static 82.3/8.5 | Static water test pressure Pa Water—Cyclic 82.3/8.6 | Cyclic test pressure Stage Pa 8.2.3/8.6 _ | Cyclic test pressure Stage Pa 82.3186 | Cyclic test pressure Stage Pa b Structural test at SLS | 8.3.2 Location of transducers noted on’ drawings? _YIN 23.3 Pressure steps? Max. displacement? = mm | Members or panels Deflection/span limit ratio © Air infitration test. | Test Pa | pressure Pa I Air infiltration limit = (ims) d Waier test (static and | Pressure | Duration | Duration and spray intensity cyclic) Pa) (mins) Static 15 min, 0.05 Lim? s Cyclic 1 5 min, 0.05 Lin? s Gyclic 2 5 min, 0.05 Lim? s Cyclic 3 5 min, 0.05 lms ‘Additional water penetration requirements? e Seismic at SLS (Water test repeated after) ‘Support beam movement allowed = Number of cycles = Frequency of movemeni f BMU restraint Test load across face of sample = __kN Test load perpendicular to sample = _kN a Strength at ULS Test Pa pressure Pa h Seismic at ULS Support beam movement allowed = mm Number of cycles = Frequency of movement = Hz i Seal degradation 10% air seal removal? YIN Describe seals to be altered COPYRIGHT: < 3 E g 5 i 3 5 5 i i e 3 ASINZS 428822008 2 For a panelized or stick curtain wall system it is recommended that a sample width include at least three adjoining wall panels, This will simulate two typical mullions and two edge conditions. At the boundary of the prototype the restraint system used should be representative of the actual restraint system of the sample being tested. Variation in the degree of fixing of these restraints will influence the results of the test, Similarly, the sealing and flashing details should be representative of actual conditions, For curtain walls for multistorey buildings, it is recommended that two expansionistack joints be tested (See Figure Bl), The stiffness of the support system for the sample should be representative of the actual support system, Acceptance of the stiffness of the support system proposed should form part of the review by the Specifier. Test rig support beam | Storey Expansion or height paul slack joint 5 support Test rig -xpansion bracket support joint Mullion beam (at | Mullion Storey Expansion or height stack joint ante support brackets Expansion joint (2) Panelized facade (b) Stick system facade FIGURE B1 ATYPICAL CROSS-SECTION OF A BUILDING FACADE INDICATING TWO INTERMEDIATE EXPANSION/STACK JOINTS. Often no single panel of a building facade is representative of all the areas of the facade that the Specifier requires to have tested. The test sample can be designed specifically to include different areas of the facade within the test sample, such as comers, overhangs. column junctions, and changes to materials. ‘The stiffness of the curtain wall mullions in the test sample will almost never be identical 1 the typical curtain wall on the actual building. The actual curtain wall mullion will have different stiffness in the bottom and top two or three floors due to different start and end (boundary) conditions. There will often also be floors of different heights and longer mullions with extra added stiffeners and/or fixings. COPYRIGHTLicensed to Malinda J Paraggio.on 06 Aug 2008, 1 user personal user cence aly. Storage, dstibution or use on network prohibited, a ASINZS 4284:2008 APPENDIX B SAMPLE PREPARATION (Informative) BL INTRODUCTION The test is a method of assessment of a facade system that has been designed by a competent person to meet the specified requirements of the Specifier. It is not an alternative method of proving a facade system. This Appendix relates to the preparation of a prototype test sample of the building facade. The two most important objectives in testing building facades are to evaluate the performance of the sample under exposure to simulated environmental conditions before production commences and to use the sample as an opportunity for the manufacturer to evaluate the fabrication and installation of the sample These objectives are based on the premise that the sample is a faithful representation of the proposed design (ie., from drawings and design calculations) and, with the test amendments, a sample of the wall that will be constructed on to the building within the construction tolerances of the structural elements of the building. This facade-testing Standard provides the method for testing the facade, using a full-scale prototype of the wall under actual design conditions. A prototype has the advantage that performance of actual materials in the facade, interaction at joints and fixing points, and visual appearance, can be critically assessed. It is possible that as part of the testing procedure some modification will be required to each the acceptance criteria successfully. The modifications will usually be related to penetration of water, but could also include deflection performance of the building facade frame or glass, or slippage at the joints or fixing points. Modifications are permitted as part of the design development: however, it is important the modifications be documented in the test report. These modifications must then be incorporated in the ‘as-manufactured’ and ‘as-built’ facade, so that defects noted in testing do not recur on the actual project. ‘There have been instances where several tests were required before the facade met the required criteria to pass the test which can raise doubts with the specifying Specifier as to whether the wall is satisfactory. It is recommended, therefore that, if after four tests, modifications are still required, the designer should carry out a detailed review of the design. Further testing should only proceed when the problem has been identified and agreement has been reached with the specifying Specifier. B2 TEST SAMPLE For reasons given in Paragraph Al the sample of facade selected for testing should be representative in size and shape of the facade of the building, taking into account number of storeys and extent in plan, ‘The aim is to simulate actual conditions so that the assumed design criteria relating to air infiltration, waterproofing and structural aspects, including deflection, performance at joints, and structural behaviour of the elements, can be assessed with confidence, Where a facade is designed with a jockey sash or internal sash, not an integral part of the weatherproofing or structural performance of the facade, it is, nevertheless, recommended that this element be included in the prototype test sample. Removal of the sash may adversely influence air infiltration through penetrations for fixings and locks, COPYRIGHTFy ASINZS 428422008 The curtain wall designer should choose a representative part of the curtain wall for the test sample. Sometimes the structural test is run twice; once with one bracket per floor and a second time at higher building comer wind pressures with double fixings. The actual chosen test sample mullion set-up should be analyzed to determine its expected structural performance (deflection) during the structural test, The analysis must take account of the actual fixings of the curtain wall members to the structure: in particular, the fixity of the flashing at the top of the curtain wall must be correctly assessed. The deflection should then be re-assessed in accordance with this analysis. The expected deflection for the test sample may be more or less than the listed nominal requirement in this Standard. ‘The expected value should be a pointer to adequate performance on-site and that the system satisfies the specified criteria. Similarly, the maximum deflection point may not be at the middle point between supports and the transducer position should be chosen accordingly. It may also be appropriate to position one transducer at the middle point between supports and one at the expected maximum deflection point The final test sample configuration and its analysis should be agreed with the Specifier on the project. Selection of the test sample configuration is often made before the facade contract is awarded, so it may be necessary to modify the test sample configuration during the design development to suit the contractor's final design and the test rig size and capability. ‘Test rigs are available where multiple test samples can be tested within the one rig, such as side by side or back to back. This provides greater scope for testing elements of the facade. Where design loadings vary for the different samples, the rig should be able to be blocked off for each sample or one of the samples modified to accept the higher loading without distress The Standard has not included any provisions to test louvres; however, louvres may form part of the sample to simulate the boundary effeets of adjacent facade panels, provided the inside face of the unit is sealed B3_ REQUIREMENTS Materials selected for the test sample are to be actual materials used for the facade. However, where these materials do not directly influence the performance of the sample under test, such as glass selection or special coatings, it is possible to test the sample with substituted materials, Use of substitute materials requires careful assessment by the designers and the Specifier, Such substitutes should be documented and included on test sample drawings and noted in the test report Where pressure equalization is specified by the Specifier, it means that the pressure in the cavities of the facade are similar to the outside pressure in service. Under this condition the rear or inner seal of the facade provides the air and watertightness In some instances the facade designer may detail the spandrel cavity as a pressure-equalized zone to the external air pressure, to prevent water entry through a pressure drop and a failure in the external seal. The manufacturers have generally used thin metal sheets, known as back-pans, to contain the air pressure, and in some instances these sheets are not stiffened. As traditional engineering analysis of these sheets and their fixings (especially fixing spacing) tend to give conservative results it is essential that a less conservative design be adequately tested and that the test sample contain at least four back-pans, if the design is to be confirmed by the performance test. Generally the test facility will measure the pressure in the pressurized spandrel cavity and plot it against the external pressure. The Specifier may require this test data reported in the final report, 1a J Paraggio on 06 Aug 2008. 1 user personal use cence only. Storage, dstnbution or use on network prohibited In order to monitor the sample under test conditions, transparent viewing panels (or other means of observation, such as optical fibre probe) should be provided, so that water performance in the cavities, in areas not readily seen, can be observed during the static and cyclic water tests Licensed to Mi copyRIGHTASINZS 428422008 a The Specifier determining the sample shape and size should also take into account the worst specified project construction tolerances. This will generally entail a maximum distance between the structure and the building facade and the distance between horizontal structural elements (simulated floor edge beams) to be at or near maximum tolerance, so that ‘movement joints are set in their most open position. If the sample is to be subjected to forced racking (seismic tests) and/or vertical movements (i.e., column shortening test) special consideration should be given to movement joint setting positions, so that the joint full open and full closed positions are tested, but not exceeded. B4 INCLINED GLAZING The SIROWET method upon which this Standard is based was originally developed to test the performance of vertical facades. If inclined or overhead glazing systems are to be included in the test it may be necessary to vary test pressures to simulate the design wind pressures on these surfaces. This needs to be assessed by the Specifier: The application rate of water as specified in Clauses 7.5 and 7.6 for the water penetration test has been chosen to provide complete coverage of the vertical test samples to ensure that any opening or erack in the facade system is wetted This may be considered too severe for inclined surfaces and a rate representative of peak rainfall conditions at the building location may be more appropriate, This needs to be assessed by the Specifier: nes oely. Skrote| distin use oe neksiik pmo, Licensed to Melinda J Paraggia on 06 Aug 2008, 1 user personal user COPYRIGHT+ user personal user licence only. Storage, distribution or use on network prohibited Lcensed te Melinda J Paragaio on 06 Aug 2008, as AS/NZS 4284:2008, APPENDIX © STRENGTH TEST AT ULTIMATE LIMIT STATE LOADING (nformative) Structural elements of a building facade are designed and detailed by limiting stress, strain and deflections. During the design process, stresses and strains are easily interchanged in the calculations; however, on the prototype facade stresses are only determined by measuring strains, The most common method of determining strain is by strain gauges meticulously attached to the accessible aluminium surfaces. Strain gauging metal surfaces is cumbersome, difficult and costly in comparison to deflection measurements. Also, when measuring strains the test engineer has to assume maximum strain locations and these locations may be at areas where sealant is applied. Further assumptions on the structural behaviour of a component consisting of two parts may lead to results that are no better than data based on deflection measurements. These shortcomings of strain measurements have given rise to the use of a deflection limiting criterion for the struetural performance test. The limiting deflection span ratio has been based on empirical data, and the limits stated in the SIROWET Standard were satisfactory for the Australian construction experience. As noted in Appendix B, a compromise is made in regard to the selection of the size of the sample and the location of the support brackets to mullions, and the deflections on the prototype may not be truly representative of the final building facade, The building facade consultant should always compare the sample deflections with the theoretical calculations and establish reasons for significant variations, The deflection of a member is determined by a minimum of three displacement transducers. Support deflections are measured to allow for slippage and end member deflections. For example, a transom attached to the midspan of a mullion will have end span deflections that usually exceed the midspan elastic deflection of the transom. Also the span of the member should be based on the distance between the transducers, measuring the deflection of the member For panelized curtain wall systems the mullion span is the distance between the bottom of the unit to the mullion bracket (see Figure C1). The definition of mullion span is based on the curvature of the framing members under lateral loading as shown in Figure C2 for a continuous panelized or stick system. ‘The only default deflection/span ratio listed in the Standard (see Clause 9.2.1) is for framing members. This value has been derived linearly from the average decrease in wind pressure from permissible to SLS. No default deflection/span ratios are given for the elements as a direct function of the fixing system, and the Specifier should establish limits from other Standards and guidelines. In the caleulation of the positive and negative pressure deflection/span ratios, the deflections either side of the mid-mode zero stages (i.e., 22 and Z5) are used. It is uncommon for the deflection/span ratios to be equal for a similar positive or negative structural test pressure, due 10 the effects of slippage in the elements of the framing members, coPyRIGHTLicensed to Melinda J Paraggia 0n 06 Aug 2008.1 user personal user licence only Storage, distribution or use on network prohdited AS/NZS 4284:2008 26 Expansion or stack joint Mullion Mullion bracket FIGURE C1 ATYPICAL CROSS-SECTION OF A PANELIZED BUILDING FACADE INDICATING THE FLOOR TO FLOOR HEIGHT (A), THE PANEL HEIGHT (B) THE VISION MULLION SPAN (C1) AND THE SPANDREL MULLION SPAN (C2), SOMETIMES NOTED BY MANUFACTURERS The test facilities will also generally interpolate or extrapolate from the actual calibrated pressure to the nominated test pressure as the air-handling system cannot be held constant at the nominated pressure due to chamber leakages and the precision of the pressure flow devices. In these cases it is considered that linear interpolation or extrapolation is acceptable when the difference in pressure from the nominated to the measured is within +2% and 45% for test facilities and field sites respeetively. With the structural performance test pressure changing from a working stress pressure (i.e, permissible stress limit) to a SLS pressure, the accumulated damage to the glass panels has been reduced and the probability of glass failing during testing of the sample is lowered. Some regions may have lower ratios of serviceability to permissible limit state pressure, so the ultimate load may become critical in these arcas. ‘The maximum displacement limit (see Clauses 8.3.7 and 9.2.3) om the sample that was specified in the SIROWET Standard was based on research findings. This limit has also been confirmed by testing at CSIRO Manufacturing and Infrastructure Technology to be satisfactory and prudent in terms of user comfort, With the change from permissible to SLS pressures the deflection limit has changed to the default of 20 mm and applied to the framing members. The architect and building owner should be aware that the centre lateral deflection on large glazing units may be high in strong winds and cause concern among, COPYRIGHTLicensed fo Melinda J Paraggio on 06 Aug 2008, 1 user personal user cence only. Storage, cistrbutlon or use on network prohibited Panol joint /-Flxing i Detlected facade under loading Panel joint Fixing i (a) Single fixing ASINZS 4288:2008 Panel joint Lo Fixing Deflected facade under loading: Panel joint £ Fixing (b) Double fixing FIGURE C2 TYPICAL DEFLECTED SHAPES OF A CONTINUOUS PANELIZED OR STICK SYSTEM FRAME UNDER LATERAL LOADING WITH SINGLE AND DOUBLE FIXING SYSTEMS. COPYRIGHTsence ony. Storage, dition or use on network prohibited Licensed to Melinda J Paraggto on 06 Aug 2008. 1 user personal usar ASINZS 4284:2008 2 During the calculations of the maximum displacement it is also acceptable to interpolate or extrapolate the deflection based on the small difference between the measured and nominated test pressure. The small difference noted previously (i.e., +2% and +5% for test facility and field sites respectively) can occur, due to difficulties in testing large samples in externally mounted and internally mounted chambers, Another limit adopted from the SIROWET Standard is the slippage of members at the ‘at rest” pressures. The Committee has considered that there is no apparent reason to change these values even though some criticisms have been expressed by manufacturers that the 3 mm limit should be increased for large panels with an area exceeding 10 m*. Currently there is no research data to indicate that the 3 mm limit should be increased and, in addition, it may not be appropriate to change the limit as the wind loading induced on to the test sample is lower, due to the lower test pressures (i.¢., permissible to SLS). Therefore, this Standard has maintained the default 3. mm limit, ‘The 1 mm support slippage limit in the SIROWET Standard has been deleted as experience has shown that a sample not meeting the 3 mm limit is usually a result of slippage at the support. For large panels the Specifier may wish to limit the deflection at the top of the support bracket to avoid excessive rotation of the support. When testing samples with corer units, the horizontal slotted holes in support brackets connected to the main sample face should be avoided, due to the lateral in-plane loads applied from the comer unit. Alternatively, a locking device may be used in the facade support bracket at the corner unit, Multiple structural tests may be carried out if there is a requirement for many displacement measurements or if the sample consists of multiple loading zones. The test procedure for each test shall consist of that outlined in Clause 8.3.3(a) to (z) (see Figure B3.) Should the sample or the data collection system fail during one of the three modes in the structural test, the additional structural test shall commence at Clause 8.3.3(a). The intermediate steps of Modes | and 2 are not required if the transducer layout has not changed or one mode with all intermediate pressure steps has been completed before to the partial completion of the structural test (see Figure B4), This Standard allows for a glass unit to break during the structural test at ultimate limit state load as it is statistically unreasonable for glass to maintain integrity when subjected to the ultimate limit state pressures. The intent of accepting the failure of an additional glass unit is based on the same strength premise; however, the replacement glass in the same unit ona sample should not fail. The failure should always be investigated as it may be caused by excessive frame deflections. Where the cause of breakage of a glass unit has been identified as handling damage by the test engineer or the Specifier, it is common in the industry for a replacement timber panel to be attached to the sample and the structural test at ultimate limit state test restarted if'a similar glass unit is on the sample. copyRiGHTistibulon or use on neon prohibited [Licensed to Melinda J Paraggio on 08 Aug 2008. 1 user personal user licence only, Stor 2» ASINZS 4284:2008 Pressure Mode + Mode 3! Moda 1 Mode 3 Mode 2 Mode 2 ———— test 1. ———+=—_ test 2. ——_+ NOTE: The take-up forthe second test not nasessay. FIGURE C3. TEST PROCEDURE FOR MULTIPLE STRUCTURAL PERFORMANCE TESTS Pressure Mods + [Moda 4 Mode 9 ' fy ill ' | Time est fault a | —— Tost 1 et Tost 1 repeat ‘NOTE: In this ease the intermediate steps of Mode I are not neces FIGURE C4 TEST PROCEDURE FOR STRUCTURAL PERFORMANCE TESTS. WHERE EQUIPMENT OR SAMPLE FAILURE PREVENTS THE COMPLETION OF MODE 2 REFERENCE, 1 ROONAN, B. and VOROBIEFF, G. The Structural Performance of High Rise Building Facades, Second National Structural Engineering Conference 1990, LE. Aust. COPYRIGHTLicensed to Melinda J Paraggia on 08 Aug 2008, 1 user personal user lcance only. Storage, cstrbution or use on network prohibited ASINZS 4284-2008 30 APPENDIX D. AIR INFILTRATION TESTING (Informative) The air infiltration and exfiltration test results (commonly referred to as air infiltration) are used by mechanical service engineers to design air-handling and stair-pressurization systems, This test may also refleet on the water resistance performance as a ‘leaky’ sample may have a large air infiltration result. The air infiltration test is a measure of the air leakage of the whole sample, and it has always been difficult to ensure that the sample elements are representative in size in relation to the typical building floor. If openable windows are inchided in the sample, the area or length of the openings should be included in the report for information. In ASTM E283 the leakage rate is sometimes reported in terms of the area and volume per ‘crack’ length. The Specifier may wish to specify limits according to the number of openable windows per floor rather than rely on area-based air leakage rates. This condition may apply when the major area of the sample consists of an openable window. The air infiltration test is one of the most difficult tests to perform with a great degree of accuracy and the testing Specifier should take this into consideration when reviewing the results. It has been generally accepted in the industry that airflow measurements below 0.1 Lim? s are difficult to obtain using an orifice plate. However, the technique to determine air infiltration and exfiltration detailed in Clause 8.4.2 is simple and cost-effective, and assuines that the sample and chamber leakage rates do not change during the test procedure This assumption appears to hold true for most samples provided sufficient care is taken to ensure that the sample is constructed with a suitable and continuous flashing. In some situations, the air infiltration rate specified in the tests is used in the design calculation of the air-handling and stair-pressurization systems. Clause 9.3 allows the test facility 10 forego the sealing of the sample of the test if the total air loss through the sample is less than the limit, In some situations in an ‘airtight’ building, facades can make it difficult for occupants to open stair exit doors, and the Specifier may insist on a full procedure air infiltration test to establish the actual air loss through the sample. Testing has shown that the air infiltration and exfiltration rates are not necessarily similar as the stiffness of the building facade varies according to the wind loading direction. If openable windows are included in the test sample these can give different results, depending on the window seal design. This Standard has provided a default value for the air infiltration limit at a specified chamber pressure, and it is noted that the increase in the chamber pressure from the adopted value in the SIROWET Standard is indicative of the quality building facade installed on buildings. However, it is strongly suggested that the Specifier seeks to apply more suitable limits matching the needs of the building owner (see Table D1). The Specifier should note that by reducing the air infiltration rate substantially below 1.6 Lim’s this may inerease the cost of the building facade Where a sample consists of a large area of openable windows or doors in relation to the total sample (generally greater than 50%), a combined air infiltration limit may be stated in terms of area and length of ‘crack’, For instance, in NZS 4211, an additional allowable air loss of 0.6 L/m’s is provided for openable fixtures at 150 Pa chamber pressure. Note that two openable parts meet, such as the interlocking stiles of a sliding door, the common length is normally counted once. COPYRIGHT‘Storage, disbution or use on network prohibited Licensed to Melinda J Paraggio on 06 Aug 2008. 1 user personal user 3 ASINZS 428422008 TABLE D1 SUGGESTED AIR INFILTRATION RATES, (Chamber Pressure [Air rate limit Building Type ray (Limt.s) =150 16 All airconditioned buildings =150 80 All non-sirsonditioned buildings In view of the accuracy of the test method described in this Standard, it is an acceptable practice in the industry to report the leakage rate of the sample as the sample and chamber leakage rate (ie., when there is no seal over the sample) if the air infiltration rate is less than the limit stated by the Specifier or the default value. Should the Specifier wish to seck greater accuracy in the air infiltration measurements or if the results are near the limit, the method of determining the air leakage error noted in ASTM E283 may be used. REFERENCE, 1 ASTM £283 Test method for determining rate of air leakage through exterior windows, curtain walls, and doors under specified pressure differences across the specimen COPYRIGHTLicensed fo Melina J Paraggio on 06 Aug 2008. 1 user personal user licence any. Storage, dsiibution ar use on network prohibited. AS(VZS 428422008 2 APPENDIX. E WATER PENETRATION TE! TING (Informative) Most building facades for multistorey buildings in Australia and New Zealand are currently designed in accordance with the drained-joint and pressure-equalization principles. Water is likely to penetrate these building facades when essential parts of the wall (for instance, rain-sereen, drip edges, air seal) are not functioning, Some recent attempts to computer model this interaction by computational fluid dynamics and the physical entities have yet to create sufficient evidence to eliminate prototype testing. Inrespective of the tools used to evaluate the building facade, there are three environmental factors relating to the water test. ‘These are— (a) _ static versus eyelic applied air pressure: (b) the duration of the water test; and (©) the intensity of water sprayed on the sample, The technology for applying eyclie air pressure to simulating wind gusts on a 9 m high by 8 m wide sample, and maintaining low test costs, have frustrated engineers for decades. It is recognized that the static air chamber test is simple and reproducible, but far from reality. In an externally mounted chamber the cycling of air pressure about some mean pressure provides a nearer solution to simulate wind gust effects. Also, the cyclic air pressure can be applied to the whole sample whereas the aeroplane engine test has a limited area of simulated wind gust Air pressure values measured on unitized curtain wall samples with connecting spandrel, mullion and transom cavities and successfully designed to pressure-equalization principles indicate, in both static and cyelic pressure modes, that the internal chambers are near full pressure-equalization to the chamber pressure. Therefore, probable water penetration during a static test is by capillary suction, kinetic energy and surface tension, and these methods are the least common mechanisms for water penetration experienced today, More commonly, water penetration failure in a static test is due to out-of-plane deflections and rotations at junctions of the sample high enough to form breaks in the air seal, In Australia, the dynamic water test commenced in the 1960s using a wind generator, such ‘as an aircraft engine with a 4 m diameter propeller. The wind generator was also adopted by American engineers with the test procedure detailed in AAMA 501.183. The test wind speed is SS km/h and produces a minimum pressure of 137 Pa, Along with the low external pressure the positive airflow coverage applied on the sample is generally limited to one floor. ‘The cyclic water test using an externally mounted chamber does not provide a close approximation to natural conditions as the frequency and pressure range during a storm are rnot uniform and consistent in time. However, the eyclic action over the whole sample is, stringent and repeatable, and therefore it becomes a reliable and cost-effective method of, performance evaluation. Brown and Ballantyne (Ref. 1) recognized in the 1970s that the water penetration test pressure for both the static and cyclic tests was a function of the building height and associated with the positive wind pressure. Also, the frequency of occurrence of wind- driven rain on a building face was considered ‘somewhat less’ than the wind speeds listed in the wind code. COPYRIGHTLicensed fo Melinda J Paraggio on 08 Aug 2008. 1 user personal user iene only. Storage, cstbutlon or use on network prohibited Fe) ASINZS 428422008, Research efforts for the determination of the joint wind and rain probability commenced in the 1990s at CSIRO-DBCE (Ref. 2). One of the difficulties faced in using the data at meteorological stations was that the wind records were hourly mean wind speeds recorded at 3h time intervals averaged over the 10 min period before the hour. It was well known that the duration of many wind-driven storms lasted for 10 to 30 min. The published data did establish that (wind speeds increased for increasing return periods at a constant rainfall intensity; and Gi) for the same return period the extreme wind speeds decreased with increasing rainfall intensity In the Tate 1980s industry experts had decided to maintain the 300 Pa SIROWET test pressure for the static test and nominate the eyelie water penetration test pressure in three stages, as follows (A) Stage 1a... oe “ tS: 300 Pa to 600 Pa. (B) Stage 2 0 30% We t0 60% M,, (©) Stage 3 In Stage 2, W, refers to the structural design (i.e., positive SLS) pressure. The 300 Pa value nominated in Clause 8.5.1 is a default value, and the building facade designer should select an appropriate pressure based on the building exposure, ..on instructions from Specifier. The third component in the establishment of suitable test requirement to assess the water resistance of building facade systems is the water spray intensity at the sample, Currently the SIROWET Standard specifies 0.05 L/s m’ (or 3.0 L/min m’) whereas ASTM E547 and ASTM E331 specifies 0.057 L/s m’ (or 3.4 L/min m’), The ASTM Standard has been converted from imperial units (i.e., 4 gals/h ft’) and the water spray quantity is equivalent to the direct impingement of rain on the wall at the rate of 203 mm/h (ASTM E547) The default test duration and water spray contents have not changed from the SIROWET method; however, the proforma test sheet in Appendix A allows the Specifier to change these values, based on regional weather data In both this Standard and ASTM Standards, the water spray pattern is uniform, covers the whole sample, and is calibrated using a *catch-box’ test in accordance with ASTM E547. More importantly, the upper half of the sample has little run-off and the quantity of run-off increases down the sample. If the external dynamic air pressure is generated by propeller the water flow across the sample appears to be radial and downwards, and this provides additional kinetic energy to water. REFERENCES, 1 BROWN, N.G. and BALLANTYNE, E.R. The SIROWET Rig for Testing the Weatherproofness of Building Facades, CSIRO Division of Building Research, 1975. CHO, E.C.C. Extreme Wind Speeds During Rainfall—Proceedings of Second Workshop on Wind Engineering, Australian Wind Engineering Society, Melbourne, February 1992. 3 ASTM Test method for water penetration of exterior windows, skylights, doors, E331 and curtain walls by uniform static air pressure difference 4 ASTM Test method for water penetration of exterior windows, skylights, doors and E547 curtain walls, and doors by eyclie static air pressure difference 5 AAMA Quality assurance and diagnostic water leakage field check of installed 501.2 storefronts, curtain walls, and sloped glazing systems coPyRiGHTLicensed to Melinda J Peragolo on 06 Aug 2008.1 user personal user icence only. Slorage, cistibuion or use on network prohitited ASINZS 42842008 4 APPENDIX F SEISMIC TESTING (Informative) Designing a building facade for earthquake resistance requires a full understanding of the behaviour of the building when subjected to seismic ground motions, In most instances the building structure will vibrate to its first mode of vibration and this may be calculated using the approximation in AS 1170.4 and NZS 1170.5. The structure vibration is generally much lower than the natural frequency of vibration of the building facade components It is costly to design and construct a building to withstand the maximum probable earthquake and therefore the designer and the building owner are required to establish an acceptable level of damage at an appropriate risk level. The acceptable level of risk should include the degree of glazing unit collapse, the reduction in air and water penetration resistance, and other performance indicators relevant to the type of facade. It is common to allow for post-elastic building response during ultimate limit state earthquakes. This is implied in the building response factor (Rj), and deflection amplification factor (Ka) of AS 1170.4, and in Section 7 of NZS 1170.5. The calculated elastic deformation should be amplified by Ky or in accordance with Section 7 of NZS 1170.5 to determine the maximum post-elastic response at roof level. This maximum response is then applied as an ultimate limit state drift In “shear-walled” buildings the maximum drift can usually be assumed to be linear up to building height. In *framed’ buildings 75% of the maximum drift is likely to oceur over the lower six storeys and the ultimate drift limit specified in the test should make allowance for this effect. It is common for post-elastic drift to be factored by 1.3 to allow for secondary effects, such as plastic hinge elongation and “floor growth’ (i.e., known to occur during extreme response) Because the forces for displacement of shear-wall facades are generally greater than those that can be achieved in a prototype test enclosure and the likelihood of glazing components set in these shear-walls are not dimensionally stressed during seismic events, it is recommended that seismic testing within the scope of this Standard should only be undertaken with flexible framed systems, such as stick and panelized curtain walls and light frame construction. This appropriate value of d, at serviceability and d, at the ultimate limit state seismic displacement should be determined by the building structural designer, ‘The seismic test program has been developed for in-plane displacements only and typical of the building racking initiated by the movement of one floor relative to adjacent floors (i.e., inter-storey drift), At the SLS, the structural system and building facade should remain in the elastic state and it is anticipated that the building owner would expect the building to be functional after this seismic loading In Clause 7.9 of this Standard, a water penetration test by cyclic pressure is recommended after a seismic test at the SLS displacement to observe the change in performance of the sample. In some test specifications the consultant has specified an additional air infiltration test, However, it is difficult to get significant results, due to the damage to the surrounding, flashing during the seismic loading, Temporary repair techniques to the building facade may be examined after seismic loading and these repair techniques may be tested and compared against a water penetration criterion, COPYRIGHTLicensed to Nietnda J Paraggio on 06 Aug 2008, 1 user personal user ioence only. Storage, dlsnbution or use on network prohitite ASINZS 4284:2008 Test displacements and application have been detailed as sinusoidal as it is the building response rather than the ground response which is likely to be applied to the prototype. The period of cycling (1) should be sufficiently rapid to ensure a realistic slip of gaskets and seals if used in the building facade components. The New Zealand experience and research (BRANZ report) indicates that the period of displacement should be expressed as a peak . typically greater than 10 mm/s. In addition, BRANZ notes that the minimum number of cycles (n) is 10 and additional repeated cycling may be required where a dry- glaze gasket system is used. REFERENCE 1 THORNTON, SJ and KING, B.B BRANZ Technical Recommendation No. 15 (1993), Proposed test and evaluation procedure for external curtain wall glazing systems to simulate seismic loading, COPYRIGHT36 ASINZS 428422008, NoTEs ‘ayaiyoud omiou vo asm 40 uoMnquip ‘aBeIaNg “Kun 20U809 Jo5n 98190 1889 "9002 BnY 99 Uo CIBBeIe, ¢ epUEEYY OF pOSUBOHition o use on network prof + user personal user licence only, Storage, i Licensed to Melinda J Paraggio on 06 Aug 2008, Standards Australia Standards Australia is an independent company. limited by guarantee, which prepares and publishes ‘most of the voluntary technical and commercial standards used in Australia. These standards are developed through an open process of consultation and consensus, in which all interested parties are invited to participate. Through a Memorandum of Understanding with the Commonwealth government, Standards Australia is recognized as Australia's peak national standards body. Standards New Zealand ‘The first national Standards organization was created in New Zealand in 1932. The Standards Council of New Zealand is the netionsl authority responsible for the production of Standards, Standards New Zealand is the trading arm of the Standards Council established under the Standards Act 1988, AustralianiNow Zealand Standards Under a Memorandum of Understanding between Standards Australia and Standards New Zealand, Australian/New Zealand Standards are prepared by committees of experts from industry, governments, consumers and other sectors, The requirements or recommendations contained in published Standards are @ consensus of the views of representative interests and also take account of comments received trom other sources, They reflect the latest scientific and industry experience. Australian/New Zealand Standards are kept under continuous review after publication and are updated regularly to take account of changing technology, International Involvement Standards Australia and Standards New Zealand are responsible for ensuring that the Australian and New Zealand viewpoints are considered in the formulation of international Standards and that the latest international experience is incorporated in national and Joint Standards. This role is vital in assisting local industry to compete in international markets. Both organizations are the national ‘members af ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission). Visit our web sites www.standards.org.au www.standards.co.nz www.standards.com.auLicensed to Melinda J Paraggio en 06 Aug 2008, 1 user personal user cence only. Storage, dstbutio or use on network prohibited. SBN 0 7337 86197 {GPO Box 478 Syiney NSW 2001 Aaiministrtion Phone 02 9237 6000 Fax (02) 9257 e010 Emel misiandrds or a0 Customer Service Phone 1500854645 ax 12008549 49 Email
[email protected]
Internet uv standards. org eros Level 10 Ris New Zealand House 165 The Tevace Wangan 6001 (Prats Bog 2430 Wengen 6020) Phone (0) 498 S880 Fax (04 408 5058 (Customer Series (04 408 £001 Information Service (04 458 5862 mall
[email protected]
Internet nn standards 0.02 Printed in Australia
You might also like
AS 1428.1-2021 Scan - Disabled Code AS 1428.1-2021 Scan - Disabled Code
PDF
100% (10)
AS 1428.1-2021 Scan - Disabled Code AS 1428.1-2021 Scan - Disabled Code
127 pages
The Australian House Building Manual
PDF
100% (5)
The Australian House Building Manual
128 pages
AS1684.1 Residential Timber-Frame Construction
PDF
82% (11)
AS1684.1 Residential Timber-Frame Construction
121 pages
AS2047-2014 Windows and External Glazed Doors in Buildings
PDF
100% (4)
AS2047-2014 Windows and External Glazed Doors in Buildings
73 pages
AS1428 - Design For Access and Mobility (2021)
PDF
100% (8)
AS1428 - Design For Access and Mobility (2021)
126 pages
BS 8102 2022 Protection of Below Ground Structures Against Water
PDF
100% (6)
BS 8102 2022 Protection of Below Ground Structures Against Water
60 pages
AS 1100 Part 301 Architectural Drawing
PDF
82% (11)
AS 1100 Part 301 Architectural Drawing
24 pages
As4100 PDF
PDF
90% (10)
As4100 PDF
220 pages
AS2159 Piling - Design and Installation
PDF
100% (7)
AS2159 Piling - Design and Installation
99 pages
1170 2-2021
PDF
100% (11)
1170 2-2021
124 pages
AS 1684 2-2006 Residential Timber-Framed Construction - Non-Cyclonic Areas - SEE IMPORTANT NOTE PDF
PDF
100% (10)
AS 1684 2-2006 Residential Timber-Framed Construction - Non-Cyclonic Areas - SEE IMPORTANT NOTE PDF
265 pages
4773.1-2015 - Masonry in Small Buildings - Design
PDF
100% (6)
4773.1-2015 - Masonry in Small Buildings - Design
109 pages
As 1428.4.1-2009 Tgsi
PDF
100% (3)
As 1428.4.1-2009 Tgsi
84 pages
AS 3727-1993 Guide To Residential Pavements
PDF
No ratings yet
AS 3727-1993 Guide To Residential Pavements
17 pages
Eurocode 2 Design of Concrete Structures BS en 1992-1-1 2023
PDF
100% (3)
Eurocode 2 Design of Concrete Structures BS en 1992-1-1 2023
408 pages
As 1530.4-2005 PDF
PDF
100% (5)
As 1530.4-2005 PDF
165 pages
AS1170.1 (1989) SAA - Loading Code - Dead and Live Loads
PDF
100% (8)
AS1170.1 (1989) SAA - Loading Code - Dead and Live Loads
31 pages
AS 1170.0 - 2002 Structural Design Actions - General Principles
PDF
100% (10)
AS 1170.0 - 2002 Structural Design Actions - General Principles
21 pages
AS 1170.4 - Earthquake Actions in Australia - 2007 PDF
PDF
90% (10)
AS 1170.4 - Earthquake Actions in Australia - 2007 PDF
57 pages
Australian Standard: Residential Slabs and Footings
PDF
17% (12)
Australian Standard: Residential Slabs and Footings
8 pages
As 3600 2018
PDF
100% (10)
As 3600 2018
269 pages
4773.2-2015 - Masonry in Small Buildings - Construction
PDF
100% (6)
4773.2-2015 - Masonry in Small Buildings - Construction
97 pages
As 2047-2014 (+a2)
PDF
No ratings yet
As 2047-2014 (+a2)
73 pages
As 2050-2002 PDF
PDF
100% (1)
As 2050-2002 PDF
28 pages
1720.3-2016 - Timber Structures - Residential Buildings
PDF
100% (2)
1720.3-2016 - Timber Structures - Residential Buildings
121 pages
AWA AS1288 Glass Guide
PDF
100% (2)
AWA AS1288 Glass Guide
96 pages
AWA AS2047 Installation Guide - Windows and Doors
PDF
100% (1)
AWA AS2047 Installation Guide - Windows and Doors
23 pages
AS1664.1 Aluminium
PDF
100% (3)
AS1664.1 Aluminium
81 pages
AS NZS 4505 2012 R2017
PDF
No ratings yet
AS NZS 4505 2012 R2017
53 pages
1720.4-2019 - Timer Structures - Fire Resistance
PDF
100% (3)
1720.4-2019 - Timer Structures - Fire Resistance
23 pages
BS en 14024-2004 Thermal Break
PDF
No ratings yet
BS en 14024-2004 Thermal Break
32 pages
As 1428.2-1992 Design For Access and Mobility Enhanced and Additional Requirements - Buildings and Facilities
PDF
0% (4)
As 1428.2-1992 Design For Access and Mobility Enhanced and Additional Requirements - Buildings and Facilities
7 pages
Astm E1300 16
PDF
No ratings yet
Astm E1300 16
14 pages
Sample Calculations To Australian Standard AS1170 For Design Loads For A Post To A Barrier
PDF
100% (13)
Sample Calculations To Australian Standard AS1170 For Design Loads For A Post To A Barrier
24 pages
As 4687-2007 Temporary Fencing and Hoardings
PDF
0% (1)
As 4687-2007 Temporary Fencing and Hoardings
8 pages
Guide To Standards - Architecture: Your Snapshot of Australian Standards® and Certification
PDF
100% (4)
Guide To Standards - Architecture: Your Snapshot of Australian Standards® and Certification
62 pages
AS 1530.8.1-2007 Methods For Fire Tests On Building Materials, Components and Structures
PDF
No ratings yet
AS 1530.8.1-2007 Methods For Fire Tests On Building Materials, Components and Structures
46 pages
1684.2-N1-N2-Supp 4 - MGP 10
PDF
50% (2)
1684.2-N1-N2-Supp 4 - MGP 10
61 pages
AS 1860.2-2006 Particleboard Flooring - Installation
PDF
100% (2)
AS 1860.2-2006 Particleboard Flooring - Installation
30 pages
AS1860.2-2006 Particleboard Flooring - Installation
PDF
100% (1)
AS1860.2-2006 Particleboard Flooring - Installation
33 pages
AS1288-2006 - Industry Guide
PDF
100% (1)
AS1288-2006 - Industry Guide
28 pages
As 3555.1-2003 Building Elements - Testing and Rating For Intruder Resistance Intruder-Resistant Panels
PDF
No ratings yet
As 3555.1-2003 Building Elements - Testing and Rating For Intruder Resistance Intruder-Resistant Panels
6 pages
As 3623-1993 Domestic Metal Framing
PDF
0% (1)
As 3623-1993 Domestic Metal Framing
7 pages
1720 1-2010 (+a3)
PDF
0% (6)
1720 1-2010 (+a3)
8 pages
Aama Tir-A8-04
PDF
100% (1)
Aama Tir-A8-04
66 pages
AS3600
PDF
75% (4)
AS3600
187 pages
AustralianStandard1288 - Glass in Buildings Selection and Installation
PDF
0% (1)
AustralianStandard1288 - Glass in Buildings Selection and Installation
10 pages
Australian Standard As 3715-2002
PDF
0% (1)
Australian Standard As 3715-2002
28 pages
As 2047-1999 Windows in Buildings - Selection and Installation
PDF
0% (7)
As 2047-1999 Windows in Buildings - Selection and Installation
8 pages
AAMA TIR-A11-04: Maximum Allowable Deflection of Framing Systems For Building Cladding Components at Design Wind Loads
PDF
100% (2)
AAMA TIR-A11-04: Maximum Allowable Deflection of Framing Systems For Building Cladding Components at Design Wind Loads
6 pages
Pages From Design Calculation For Facade
PDF
No ratings yet
Pages From Design Calculation For Facade
1 page
TREMCO Structural Silicone Glazing Manual
PDF
No ratings yet
TREMCO Structural Silicone Glazing Manual
44 pages
4420-5-1996 Windows Test-Water Penetration Resistance Test
PDF
No ratings yet
4420-5-1996 Windows Test-Water Penetration Resistance Test
4 pages
AS0908.2 (2000) Cellulose - Cement Products - Flat Sheets
PDF
No ratings yet
AS0908.2 (2000) Cellulose - Cement Products - Flat Sheets
22 pages
As 4420.2 Serviceability Strenght: Australian and New Zeland Test Pressure
PDF
No ratings yet
As 4420.2 Serviceability Strenght: Australian and New Zeland Test Pressure
2 pages
E2751 Design Laminated Glass Walkways
PDF
No ratings yet
E2751 Design Laminated Glass Walkways
3 pages
As 1530.1-1994 Methods For Fire Tests On Building Materials Components and Structures Combustibility Test For
PDF
0% (3)
As 1530.1-1994 Methods For Fire Tests On Building Materials Components and Structures Combustibility Test For
6 pages
As 1288-2006 Glass in Buildings - Selection and Installation
PDF
0% (2)
As 1288-2006 Glass in Buildings - Selection and Installation
10 pages
As1288-2006 Australian Standards Glass in Building
PDF
No ratings yet
As1288-2006 Australian Standards Glass in Building
8 pages
Wind Loads For Housing: (Incorporating Amendment No. 1)
PDF
0% (1)
Wind Loads For Housing: (Incorporating Amendment No. 1)
8 pages
Static Calculation CW
PDF
No ratings yet
Static Calculation CW
64 pages
AWA AS1288 Glass Guide
PDF
No ratings yet
AWA AS1288 Glass Guide
96 pages
Aama 101
PDF
No ratings yet
Aama 101
81 pages
Aama 501 - 2005
PDF
No ratings yet
Aama 501 - 2005
14 pages
AS 1170 Part1: Permanent and Other Imposed Actions
PDF
33% (3)
AS 1170 Part1: Permanent and Other Imposed Actions
3 pages
Aama Cwm-19: Curtain Wall Manual
PDF
No ratings yet
Aama Cwm-19: Curtain Wall Manual
107 pages
16 CFR Part 1201 - 2002 A
PDF
100% (1)
16 CFR Part 1201 - 2002 A
19 pages
AS4055-1192 Wind Loads For Housing
PDF
No ratings yet
AS4055-1192 Wind Loads For Housing
24 pages
As 1170.1
PDF
0% (5)
As 1170.1
7 pages
Welcome To Seminar: - Related Code of Curtain Wall/wind Load - Live Load/lateral Movement - Basic Calculation of Façade
PDF
No ratings yet
Welcome To Seminar: - Related Code of Curtain Wall/wind Load - Live Load/lateral Movement - Basic Calculation of Façade
76 pages
4455 1-2008
PDF
100% (2)
4455 1-2008
29 pages
Macau Wind Code
PDF
No ratings yet
Macau Wind Code
53 pages
As 1170.0-2002 Loading Code General
PDF
100% (4)
As 1170.0-2002 Loading Code General
47 pages
Masonry
PDF
0% (1)
Masonry
8 pages
prEN 13474 2 99 Glass in BLDG Design For Uniformly Dist Loads PDF
PDF
No ratings yet
prEN 13474 2 99 Glass in BLDG Design For Uniformly Dist Loads PDF
54 pages
Australian/New Zealand Standard: Testing of Building Facades
PDF
No ratings yet
Australian/New Zealand Standard: Testing of Building Facades
7 pages
Facade Performence Laboratory Company Profile_Rev.00 (1)
PDF
No ratings yet
Facade Performence Laboratory Company Profile_Rev.00 (1)
12 pages
Drift Demand On Facades
PDF
No ratings yet
Drift Demand On Facades
10 pages
TAS 203-94 - Criteria For Testing Products Subject To Cyclic Wind Pressure Loading
PDF
No ratings yet
TAS 203-94 - Criteria For Testing Products Subject To Cyclic Wind Pressure Loading
6 pages
Performance Mock-Up-Additional Impact Testing: Report
PDF
No ratings yet
Performance Mock-Up-Additional Impact Testing: Report
14 pages
As 4055-2006 Wind Loads For Housing
PDF
100% (1)
As 4055-2006 Wind Loads For Housing
57 pages
62 1112 Dow Corning Americas Technical Manual
PDF
No ratings yet
62 1112 Dow Corning Americas Technical Manual
89 pages
Etag 001 Part 5 Bonded Anchors 2013 04 08 PDF
PDF
No ratings yet
Etag 001 Part 5 Bonded Anchors 2013 04 08 PDF
33 pages
Technological Changes Brought by bIM To Facade Design PDF
PDF
No ratings yet
Technological Changes Brought by bIM To Facade Design PDF
21 pages
Curtain Wall NoAnswers
PDF
No ratings yet
Curtain Wall NoAnswers
20 pages
Gantt Chart
PDF
No ratings yet
Gantt Chart
7 pages