Wylex Solar PV
Wylex Solar PV
Switchgear Solutions
Issue 2
Solar Voltaics in Domestic Installations
Cables with a power supply at each end need special considerations.
Using Double pole RCBOs on a dedicated circuit could be the simplest answer.
1 Circuit protection for both power supplies may be required (subject to inverter operating characteristics)
P V supplies with an RCD providing additional protection for the final circuit must be DP and disconnect
2 Line and Neutral conductors (e.g. Double pole RCBO). Use of DP RCBOs may negate the need to take
account of inverter shut down times
PV supplies require DC and AC Isolators so that the inverter can be isolated from both supplies for
3 maintenance
4 PV supplies should be connected to a dedicated circuit at the consumer unit (not share a final sub circuit)
A new range of Wylex products is available to help installers meet the above
411.3.2.2
A The maximum disconnection time shown in Table 41.1 applies to circuits not exceeding 32A. 0.4 s TN System & 0.2 s TT Systems.
551.4.1
B Fault protection shall be provided for of each source of supply or combination of sources of supply.
(Also, refer to chapter 55, regulation group 551- Low Voltage Generating Sets)
551.5.1
C Over current protection should be located as near as practical to the generator terminals (where required).
712.537.2.1.1
D To allow maintenance of the PV Inverter, means of isolating the PV inverter from the DC side and the AC side shall be provided.
(Also, refer to chapter 53, regulation group 537- Isolation and Switching)
712.434.1
E The PV supply cable (AC side) shall be protected against fault current by an overcurrent protective device installed at the connection to the AC mains.
Also, refer to Part 7, all regulations in Section 712 - Solar Photovoltaic (PV) Power Supply Systems)
712.411.3.2.1.1
F The PV Supply cable (on the AC side) shall be connected to the supply side of the protective device for automatic disconnection of circuits supplying
current -using equipment.
314.1
G Every installation shall be divided into circuits as necessary to : (ii) facilitate safe inspection testing & maintenance (vi) prevent the indirect energising
of a circuit intended to be isolated.
314.4
In an installation comprising more than one final circuit, each final circuit shall be connected to a separate way in a distribution board.
The wiring of each final circuit shall be electrically separate from that of every other final circuit, so as to prevent the indirect energising of a final circuit
intended to be isolated.
522.6.101 522.6.102 & 522.6.103
I Installers must consider the need for Additional Protection by 30mA RCD in accordance with regulations (Previously 522.6.6 & 522.6.8) that relate to
concealed cables in walls & partitions.
Wylex have created a number of new PV dedicated products to help installers to economically and efficiently
install Solar Photovoltaic (PV) Systems up to 4kW, including:
AC & DC Enclosed Isolators Combination DC/AC PV Isolator in a single enclosure
Dual Supply PV & Grid Mains Supply Switch PV Consumer Units (all 17th edition models available)
The equipment is designed to allow the installer to make parallel power connections simply and easily.
A
1 A
B 1
2 B
C 2
3 C
D 3
D
I
I
E E
4 F 4
F
5 G Existing 5
Consumer G
* Unit *
NSPE-5359/5
REC Isolator
100A, 230V AC DP 2 Module Isolator, lockable 40A, 230V AC DP
2 Module Isolator, lockable Enclosure with split cover and meter
seal and seal-able security screw. NHDSREC4
NHDSREC4
PV CONSUMER UNIT
DESCRIPTION LIST No.
Insulated metered consumer unit supplied with either Main Switch
and 16A SP MCB or 16A RCBO with optional MID meter.
63A 320V AC DP Isolator
16A B Curve SP MCB
40A direct read MID Meter.
Ready assembled consumer unit complete with MID Certified meter
Combined unit simplifies and speeds up installation
Complete with Isolator & MCB
Easy read permanently displayed kWh reading
Option available with RCBO or MCB
Note: Surge Protection devices and Type B RCDs are available on request
DC ISOLATOR
DESCRIPTION LIST No.
DC Isolator in an all insulated enclosure with rotary handle and
padlock locking Off facility.
Multi Pole
25A, 32A, 40A
500V or 600V DC
Insulated Enclosure
Rotary Handle & padlock ‘Off ’ facility
DC - 21B utilization category
NHDC406006P NHDC405004P
AC ISOLATOR
DESCRIPTION LIST No.
AC Isolator in an all insulated IP65 enclosure with rotary door
interlock and padlock locking Off facility.
Multi Pole
16, 25 or 32A
230V AC
IP65 Enclosure
Rotary Handle & padlock ‘Off ’ facility
NHTPSD32 NHTPSD25
NHSPMTRA NHSPMTRD
Note: Surge Protection devices and Type B RCDs are available on request
Main Switch Dual Supply PV Consumer unit with MID Certified Generation Meter
DESCRIPTION LIST No.
15 way unit with dual supply isolators & 16A SP MCB NH15DSMPVF
10 way unit with dual supply isolators & 16A SP MCB NH10DSMPVF
14 way unit with dual supply isolators & 16A DP RCBO NH14DSRCBMPVF
9 way unit with dual supply isolators & 16A DP RCBO NH9DSRCBMPVF
Main Switch Dual Supply PV Consumer unit
16 way unit with dual supply isolators & 16A SP MCB NH16DSPVF
11 way unit with dual supply isolators & 16A SP MCB NH11DSPVF
15 way unit with dual supply isolators & 16A DP RCBO NH15DSRCBPVF
10 way unit with dual supply isolators & 16A DP RCBO NH10DSRCBPVF
Double Pole MCB options available on request
NH14DSRCBMPVF
Split Load Dual Supply PV Consumer unit with MID Certified Generation Meter
DESCRIPTION LIST No.
13 way unit with dual supply isolators & 16A SP MCB NH13DSMPVSL
8 way unit with dual supply isolators & 16A SP MCB NH8DSMPVSL
12 way unit with dual supply isolators & 16A DP RCBO NH12DSRCBMPVSL
7 way unit with dual supply isolators & 16A DP RCBO NH7DSRCBMPVSL
Split Load Dual Supply P V Consumer unit
14 way unit with dual supply isolators & 16A SP MCB NH14DSPVSL
9 way unit with dual supply isolators & 16A SP MCB NH9DSPVSL
13 way unit with dual supply isolators & 16A DP RCBO NH13DSRCBPVSL
8 way unit with dual supply isolators & 16A DP RCBO NH8DSRCBPVSL
Double Pole MCB options available on request
NH12DSRCBMPVSL
High Integrity Dual Supply PV Consumer unit with MID Certified Generation Meter
DESCRIPTION LIST No.
11 way unit with dual supply isolators & 16A SP MCB NH11DSMPVHI
10 way unit with dual supply isolators & 16A DP RCBO NH10DSRCBMPVHI
High Integrity Dual Supply P V Consumer unit
12 way unit with dual supply isolators & 16A SP MCB NH12DSPVHI
11 way unit with dual supply isolators & 16A DP RCBO NH11DSRCBPVHI
Double Pole MCB options available on request
NH10DSRCBMPVHI
Dual RCD Dual Supply PV Consumer unit with MID Certified Generation Meter
DESCRIPTION LIST No.
11 way unit with dual supply isolators & 16A SP MCB NH11DSMPVDR
6 way unit with dual supply isolators & 16A SP MCB NH6DSMPVDR
10 way unit with dual supply isolators & 16A DP RCBO NH10DSRCBMPVDR
5 way unit with dual supply isolators & 16A DP RCBO NH5DSRCBMPVDR
Dual RCD Dual Supply PV Consumer unit
12 way unit with dual supply isolators & 16A SP MCB NH12DSPVDR
7 way unit with dual supply isolators & 16A SP MCB NH7DSPVDR
11 way unit with dual supply isolators & 16A DP RCBO NH11DSRCBPVDR
6 way unit with dual supply isolators & 16A DP RCBO NH6DSRCBPVDR
Double Pole MCB options available on request
WRCBL32C2
NSPE - 5580
MCB Accessories
DESCRIPTION LIST No.
Padlock 3mm Hasp WPL
SP MCB Dummy Blank NHB1PP
SP Blanking plate-twist fit NH00PP
DIN Enclosure IP40 ESE2
Locking device for MCB MCBLDX
ELECTRIUM SALES LIMITED A SIEMENS COMPANY
Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS11 0XE.
eMail: [email protected] Web: www.electrium.co.uk
UK SALES
Telephone: 01543 455020 Facsimile: 01543 455021 eMail: [email protected]
TECHNICAL
Telephone: 01543 438320 Facsimile: 01543 438321 eMail: [email protected]
EXPORT SALES
Telephone: +44 1543 455049 Facsimile: +44 1543 455048 eMail: [email protected]
DUBAI OFFICE
Telephone: +971 4 3660687 Facsimile: +971 4 3660676
Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Wylex.