Perten DA 7250 - Moisture in Wooden Boards

The document discusses using near infrared reflectance (NIR) to measure board moisture in wood panel production. It summarizes that the DA 7250 NIR analyzer can measure board moisture in only 6 seconds, providing advantages over the standard 24 hour EN 322 method. Validation testing on hundreds of samples from wood panel mills showed the DA 7250 results were highly accurate compared to the reference EN 322 method.

Uploaded by

aaaq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
200 views4 pages

Perten DA 7250 - Moisture in Wooden Boards

The document discusses using near infrared reflectance (NIR) to measure board moisture in wood panel production. It summarizes that the DA 7250 NIR analyzer can measure board moisture in only 6 seconds, providing advantages over the standard 24 hour EN 322 method. Validation testing on hundreds of samples from wood panel mills showed the DA 7250 results were highly accurate compared to the reference EN 322 method.

Uploaded by

aaaq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Analysis of board moisture in

wood based panels production

Bo c
ard 6 se
Moisture in

Laboratory and Process Instruments and Support


In only 6 seconds...
Producers of wood based panels need to control and optimize the manufacturing process.There
are also industry and official standard requirements to measure several process parameters like for
instance board moisture.The EN 312 standard requires board moisture to be measured with the
EN 322 method after each 8 hours of production. Each formaldehyde test with EN 120 also
requires determination of board moisture according to EN 322 to correct the perforator value to
6,5 % moisture.The EN 322 standard method takes 24 hours to complete.
The Near Infrared Reflectance (NIR) technique is particularly suited for measurement of
moisture in board samples. Recent advances in instrumentation and calibration technology that
have enabled stable and precise measurements.

DA 7250 NIR Analyzer


The DA 7250 is a new full-spectrum,
Diode Array
NIR instrument designed for use in
process environments. Using novel
diode array technology it performs
a multi-component analysis in only
Stationary Grating

6 seconds with no or little sample


preparation required.
During these 6 seconds, a baseline is collected,
noise monitored, wavelength accuracy is standard-
ized, and a large number of full spectra are collected.

Advantages
• Short analysis time
• Automatic documentation of
results, no risk for typing errors
• Save personnel resources
• No limitation in oven capacity
• The EN 120 uncorrected value can
be moisture corrected directly after
it is measured using the DA 7250
moisture measurement
DA 7250 for board moisture
factory production control
The EN 322 method can be replaced with the
DA 7250 board moisture measurement using the
procedure described in EN 326-2.

Fu
Experimental rn
itu
Several hundred samples from wood- re,
Floo
based panel mills were collected. r, Stairs and more
The samples were analyzed on
multiple DA 7200 and DA 7250
analyzers following the procedure A calibration was developed by
described in the “DA 7250 Quick Perten Instruments, with the following statistics:
Guide v1.0 appendix EN moisture testing”. With Number
this procedure the board samples are cut in pieces Parameter of samples Range R
and measured from the edge. Reference analyses Board moisture ~ 500 3,8-9,4 % 0,96
were performed by the mills according to EN 322. dry based

The DA 7250 results are very accurate when


compared to the results from the reference method

Figure 1. Validation results from one particle Figure 2. Cross validation results
board mill. 33 validation samples showed an SEP of for the board moisture calibration.
0,34 % moisture, R2= 0,92, Slope=0,97
Ver 1.0 2015.05.01
Global expertise, local support
We supply solutions to our customers – support after the sale is as important as the
instrument itself. Our teams of technicians and applications specialists, and the ser-
vices they provide, ensure our customers continue to get the most benefit during
the entire life of the instrument. We provide service, training classes, calibration
development, method development and other customized programs and services.
We are active in nearly every part of the world. We serve you through our direct
offices and our extensive network of highly qualified, experienced and trained
distributors. Our distributors are an important part of Perten Instruments team
and many have been with us for more than 25 years.
To find out more about Perten Instruments, our products or local support,
please visit our website at www.perten.com

Perten Office
Perten Distributor

www.perten.com

You might also like